Concrete and Reinforcement Specifications
Concrete and Reinforcement Specifications
PERSPECTIVE
A. GENERAL UNLESS OTHERWISE SHOWN ON DRAWINGS, SPLICES SHALL BE STAGGERED REBAR REBAR
12 x db
1. CONSTRUCTION NOTES & TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS WHENEVER POSSIBLE. MIN. LAP SPLICE
OTHERWISE SHOWN OR NOTED, MODIFY TYPICAL DETAILS AS DIRECTED TO MEET ANCHORAGE OR DEVELOPMENT
7. ALL ANCHOR BOLTS, DOWELS, & OTHER INSERTS, SHALL BE PROPERLY LENGTH OF COL
SPECIAL CONDITIONS. BAR LENGTH OF REBARS IN METERS
POSITIONED & SECURED IN PLACE PRIOR TO PLACING OF CONCRETE. LAP SPLICES (M) UNIT REINFORCEMENT
2. SHOP DRAWINGS WITH ERECTION & PLACING DIAGRAMS OF ALL STRUCTURAL
8. CONTRACTOR SHALL NOTE & PROVIDE ALL MISCELLANEOUS CURBS, SILLS, DIAMETER
WEIGHT
°
INDIVIDUAL BARS
90
STEEL, MISCELLANEOUS IRON, PRE-CAST CONCRETE ETC. SHALL BE SUBMITTED db - DIAMETER db - DIAMETER
FOR ENGINEER'S APPROVAL BEFORE FABRICATION.
STOOLS, EQUIPMENT, & MECHANICAL BASES THAT ARE REQUIRED BY THE
ARCHITECTURAL, ELECTRICAL, & MECHANICAL DRAWINGS.
in STRAIGHT W/ STANDARD HOOK TENSION BAR COMP. BAR
(kg/m)
OF REBAR OF REBAR
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE ALL WORK IS TO BEGIN, (mm)
CHECK WITH MECHANICAL & ELECTRICAL CONTRACTORS FOR CONDUITS, PIPE 9. ALL CONCRETE SHALL BE KEPT MOIST FOR A MINIMUM OF SEVEN (7) (NO HOOK) 90° 180° 133° TOP BAR BOT BAR TOP BAR BOT BAR W/ TIES W/ SPIRAL DEVELOPMENT
LENGTH
KEY PLAN
SLEEVES, ETC. TO BE EMBEDDED IN CONCRETE. CONSECUTIVE DAYS IMMEDIATELY AFTER POURING BY THE USE OF WET BURLAP, DEVELOPMENT
SHORINGS & BRACINGS OF THE STRUCTURE FOR ALL LOADS THAT MAYBE FOG SPRAYING, CURING COMPOUNDS OR OTHER APPROVED METHODS. 10 0.60 0.10 0.13 0.10 0.42 0.30 0.42 0.30 0.617 0.30 0.30 LENGTH
°
SUSPENDED SLABS 6,000 PSI 3/4 IN. (19MM.) 4 IN. (100MM)
133
WALL THICKNESS VERTICAL REINFORCEMENT HORIZONTAL REINFORCEMENT
1. ACI SECTION 12.4 STATES THAT:
180°
& COLUMNS 8 IN. (200 MM.) Ø 12 @ 400 MM. Ø 10 @ 600 MM.
12
3. ALL REINFORCING BARS SHALL CONFORM TO ASTM A615 GRADE 40 FOR DIA.12mm 6 IN. (150 MM.) Ø 10 @ 400 MM. Ø 10 @ 600 MM. DEVELOPMENT LENGTH OF INDIVIDUAL BARS WITHIN A BUNDLE IN TENSION OR COMPRESSION
x
db - DIAMETER db - DIAMETER
db
& SMALLER BARS & GRADE 60 FOR DIA. 16 & LARGER BARS. COLUMN OF REBAR OF REBAR
4 IN. (100 MM.) Ø 10 @ 400 MM. Ø 10 @ 600 MM.
HOOPS ARE ALL GRADE 60 BARS. SHALL BE THAT FOR THE INDIVIDUAL BAR. INCREASED 20 PERCENT FOR THREE-BAR
4. IN GENERAL, THE LATEST EDITION OF ACI-315, MANUAL OF STANDARD PRACTICE 5. REINFORCING BARS SHALL BE LAPPED A MINIMUM OF 30 BAR DIAMETERS WHERE
DETAILING REINFORCED CONCRETE STRUCTURES SHALL BE ADHERED TO UNLESS SPLICED. DOWELS FROM CONCRETE FOOTINGS OR SLABS SHALL EXTEND INTO
BUNDLE AND 33 PERCENT FOR FOUR-BAR BUNDLE. 12 x db
OTHERWISE SHOWN OR NOTED. THE BLOCK WALL A MINIMUM OF 30 BAR DIAMETERS, & DOWELS TO MATCH
5. MAINTAIN MINIMUM CONCRETE COVER FOR REINFORCING STEEL AS FOLLOWS: VERTICAL REINFORCEMENTS OF WALL. 2. FOR COLUMNS AT ANY LEVEL NO MORE ALTERNATE BARS SHOULD BE SPLICED NOT
DEVELOPMENT LENGTH FOR REBARS WITH DEVELOPMENT LENGTH FOR REBARS WITH
SUSPENDED SLABS ................................................. 3/4 IN. (19MM.) 6. ALL CELLS CONTAINING REINFORCING BARS OR INSERTS SHALL BE SOLIDLY MORE THAN 33% OF THE BARS SHALL BE SPLICED WITHIN THE REQUIRED LAP LENGTH 180° STANDARD HOOK ANCHORED TO CONCRETE 133° STANDARD HOOK ANCHORED TO CONCRETE
SLAB ON GRADE ......................................................1 1/2 IN. (38MM.)
FILLED WITH CONCRETE GROUT. (REFER TO SPECIFICATIONS)
MINIMUM DISTANCE BETWEEN TWO ADJACENT BAR SPLICES SHALL BE 600MM. OWNER
D. FOUNDATION
WALLS ABOVE GRADE ..............................................1 IN. (25MM.) 1. FOUNDATION IS DESIGNED FOR ASSUMED ALLOWABLE SOIL BEARING 3. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 300 MM DEPTH OF CONCRETE CAST
BEAM STIRRUPS & COLUMN TIES ............................1 1/2 IN. (38MM.) CAPACITY OF 6,500 PSF. BELOW THE REINFORCEMENT.
2. FOUNDATION SHALL REST ON NATURAL SOIL. UNLESS OTHERWISE NOTED BY
WHERE CONCRETE IS EXPOSED TO EARTH 4. AS MUCH AS POSSIBLE SPLICES SUBJECTED TO TENSILE STRESSES ARE DISCOURAGE.
THE ENGINEER, NO PART OF THE FOUNDATION SHALL REST ON FILL.
BUT POURED AGAINST FORMS .................................2 IN. (50MM.)
3. THE CONTRACTOR SHALL NOTIFY THE ENGINEER AFTER FOOTING EXCAVATION THESE SHOULD BE AVOIDED OR PROVIDED WITH STANDARD HOOKS.
MEASUREMENTS OF DEVELOPMENT LENGTH
WHERE CONCRETE IS DEPOSITED HAVE BEEN COMPLETED & PRIOR TO CONCRETING TO CONFIRM THE DESIGN
DIRECTLY AGAINST EARTH .......................................3 IN. (75MM.) SOIL BEARING CAPACITY. 5. ASSUMED SPECIFIED COMPRESSIVE STRESS FOR CONCRETE f'c = 6,000 PSI FOR REINFORCING STEEL
(SEE SEPARATE TABLE FOR CORRECT DIMENSION)
ARCHITECT
INTERMEDIATE
BEAM
EARTH SIDE
OPEN SIDE
300mm thk Wall
CONTRACTOR
FOOTING TIE
BEAM
DRAWING TITLE :
KEY PLAN
RW1
C4
ON TOWER E FOUNDATION
PODIUM
TB1
TB1
TB1
TB1
TB1
TB1
OWNER
TB1
TB1 TB1 TB1 TB1
TB1
TB1
TB1
TB1
TB1
ARCHITECT
RW1
F2C2
TB1
TB1 TB1 TB1 TB1
F2C2 F2C3
F1C1 F3C4 F3C4 STRUCTURE
TB1
TB1
TB1
TB1
TB1
TB1
150mm THICK SLAB-ON-GRADE WITH
10mmØ REBARS SPACED @ 600mm
O.C. BOTHWAYS. WITH 100mm THICK
WELL-COMPACTED GRAVEL BASE AND
SUB-GRADE @ 95% MAXIMUM DRY DENSITY
RW1
CONTRACTOR
TB1
TB1
TB1
TB1
TB1
TB1
SHOP DRAWING
PROJECT TITLE :
RW1
DRAWING TITLE :
16mmØ VERT. BARS on OPEN SIDE/EARTH SIDE 16mmØ VERT. BARS on OPEN SIDE/EARTH SIDE 16mmØ VERT. BARS on OPEN SIDE/EARTH SIDE 16mmØ VERT. BARS on OPEN SIDE/EARTH SIDE
spaced @ 100mm O.C. spaced @ 100mm O.C. spaced @ 100mm O.C. spaced @ 100mm O.C.
12mmØ HOR. BARS on OPEN SIDE/EARTH SIDE 12mmØ HOR. BARS on OPEN SIDE/EARTH SIDE 12mmØ HOR. BARS on OPEN SIDE/EARTH SIDE 12mmØ HOR. BARS on OPEN SIDE/EARTH SIDE KEY PLAN
spaced @ 200mm O.C. spaced @ 200mm O.C. spaced @ 200mm O.C. spaced @ 200mm O.C.
C1 C1 C1 C1 TE C9
GROUND FLR ±102.45 1B27P 1B27 1B27 1B27
1CB3P
PODIUM
NGL ±99.20
F1 F1 F1 F1
A
TP-RF-0057 1:50
ARCHITECT
GL LEFT OF A/8-12
STRUCTURE
C1 C1 C1 C1 TE C9
GROUND FLR ±102.45 1B27P 1B27 1B27 1B27
1CB3P [Link]-VB.1: 81 - 16Ø x 4500 [Link]-VB.2: 81 - 16Ø x 4500 [Link]-VB.3: 81 - 16Ø x 4500 [Link]-VB.4: 79 - 16Ø x 4500
@ 100mm O.C. (2 sets) @ 100mm O.C. (2 sets) @ 100mm O.C. (2 sets) @ 100mm O.C. (2 sets)
[Link]-HB.1: 8pcs - 12Ø x 2400 [Link]-HB.3: 8pcs - 12Ø x 9000 [Link]-HB.5: 8pcs - 12Ø x 9000 [Link]-HB.7: 8pcs - 12Ø x 9000 [Link]-HB.9: 8pcs - 12Ø x 7500
@ 200mm O.C. (2 Sets) @ 200mm O.C. (2 Sets) @ 200mm O.C. (2 Sets) @ 200mm O.C. (2 Sets) @ 200mm O.C. (2 Sets) CONTRACTOR
[Link]-HB.2: 7pcs - 12Ø x 7500 [Link]-HB.4: 7pcs - 12Ø x 9000 [Link]-HB.6: 7pcs - 12Ø x 9000 [Link]-HB.8: 7pcs - 12Ø x 9000 [Link]-HB.10: 7pcs - 12Ø x 2400
@ 200mm O.C. (2 Sets) @ 200mm O.C. (2 Sets) @ 200mm O.C. (2 Sets) @ 200mm O.C. (2 Sets) @ 200mm O.C. (2 Sets)
NGL ±99.20
CCTEB-RLD-SDW-ST-RF-TP-0057
DRAWN BY DWIGHT SCALE 1:50
CHECKED BY ANSON HAO DATE 27APR2023