Waterproofing - C2K

Birla Opus Prime C2K is a two-component waterproof coating designed for concrete and masonry surfaces, offering features like crack bridging and anti-efflorescence. The product is safe for potable water and comes with a warranty of up to 7 years. It requires proper surface preparation and specific mixing and application methods to ensure optimal performance.

Uploaded by

mvishnu1000
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
44 views2 pages

Waterproofing - C2K

Birla Opus Prime C2K is a two-component waterproof coating designed for concrete and masonry surfaces, offering features like crack bridging and anti-efflorescence. The product is safe for potable water and comes with a warranty of up to 7 years. It requires proper surface preparation and specific mixing and application methods to ensure optimal performance.

Uploaded by

mvishnu1000
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

WATERPROOFING - C2K

Cementitious 2K Coating

Birla Opus Prime C2K is a two-component acrylic cementitious, polymer modified


elastomeric waterproof coating. It is composed of cement with properly graded sand
and selected additives as one part & an acrylic emulsion as a binder in its second
part. It is applied for protection & waterproofing of concrete and masonry substrates.

PRODUCT FEATURES

POTABLE WATER ANTI-EFFLORESCENCE CRACK BRIDGING WARRANTY*


SAFE* ABILITY
Product conforms to overall Mitigates the salt Highly elastomeric coating Up to 7 years
migration test specifications as formation on the surface provides crack bridging of up waterproofing
per USFDA-175:300 conducted by maintaining the integrity to 1.2 mm. warranty*
CFTRI for intended use for contact and overall finish.
*T&C apply. For more details, please refer to the
with potable water. product warranty document.

PRODUCT DETAILS

AVAILABLE PACKS COVERAGE COLOURS AVAILABLE

Estimated forced coverage:


15kg
GRE Y
7 – 8 [Link]/kg for 2 coats**
SHELF LIFE

12 months
**Actual coverage may vary from the quoted coverage due to factors from the date
such as method and condition of application and surface roughness of manufacture
and porosity. One should ensure coverage is not higher than the one
prescribed above for optimal performance.

AREAS OF APPLICATION

Old & New Concrete, Wet Areas - Bathrooms, RCC roofs, Small terraces, Concrete
Plaster & Kitchens, Balconies chhajjas & sinks Water Tanks
Masonry surfaces

SURFACE PREPARATION
1. The surface under treatment must be strong and 2. Any previously applied putty or POP must be
cleaned thoroughly for any loose particles or laitance removed before application. The surface must
etc. before application. Oil or grease on the surface be cleaned to expose the plaster surface for
must be removed by suitable degreasing agent and application.
then washed out with jet water (about 160 bar water
pressure). Any plumbing or sanitation work must be
completed before taking up the application.

3. Any minor cracks must be filled with Birla Opus AllDry 4. In case of efflorescence or loose plaster, expose
Crack Master Paste. For larger cracks or repairs, use the surface up to the brick level. Use Birla Opus
Birla Opus repair solutions. Alldry Repair Master with mortar for replastering
the surface.
ANGLE FILLET/CORNER TREATMENT
• Moisten the RCC surface, apply a 1:1 bonding coat of Birla Opus AllDry Repair Master and Cement.
• Create a 50x50 mm angle fillet using PMM ([Link] ratio) with Birla Opus AllDry Repair Master, fresh cement, and graded quartz sand.
Moist cure for 3–4 days.
• Apply a coat of Birla Opus Prime C2K followed by laying of 45 GSM glass fiber over angle fillet when the coating is still wet. Then
apply the second coat to fully embed the glass fiber mesh, ensuring it's free from creases and air pockets.

PIPE OUTLET/BORE PACKING TREATMENT


• Ensure gaps around PVC, GI pipes are packed with Birla Opus AllDry Repair Master.
• Fill the gap around the pipe penetration points with non-shrink grout. Apply a coat of Birla Opus Prime C2K waterproofing coating
around the pipe penetration point. Ensure no gaps are left uncoated.

MIXING & APPLICATION


• Birla Opus Prime C2K liquid component must be shaken thoroughly before mixing.
• In a mixing vessel, slowly add the powder component into the liquid (1 part liquid : 2 part powder) with continuous stirring. In case of bulk
volume, use mechanical mixer. Continue to stir until a homogenous, lump free mix is achieved. Allow the mix to stand for 3 – 5 mins to
release entrapped air during mixing.
• Apply 1st coat of the mixed slurry using brush on SSD (saturated surface dry) surface. Make sure that the application is done correctly in
areas where the surface shows minor abnormalities or undulations. Add an extra 1-2 feet of mixed slurry to all sides of the affected area.
• After 4 – 6 hours, apply 2nd coat in the direction perpendicular to the 1st coat.
• Leave the coating to air cure for 2 - 3 days. Then apply plaster or screed.
• Prepare 1:3 Screed mixture (50 kg of cement to be mixed 150 kg sand). Screed thickness should be a minimum of 15 mm to 30 mm.
It needs 48 hrs of air curing followed by minimum 4 days of water curing.
• Apply 2 coats of Product on all over shower area. Sprinkle coarse quatrz sand while second coat is still wet. This will provide better
adhesion for subsequent tile adhesive materials.

SAFETY ASPECTS
• Kindly refer to the MSDS for Birla Opus Prime C2K which gives detailed information on safety measures.
• Wear eye protection during application. In case of contact with eyes, rinse immediately with
as mentioned above in "Mixing & Application" steps.
• In case of skin contact immediately wash skin with soap and plenty of water. Get medical attention if irritation develops or persists.
• Do not breathe vapour or spray. It is recommended to wear suitable nose pad during sanding and
as mentioned above in "Mixing & Application" steps.
• No added Lead, Mercury or Chromium compounds.

PRECAUTIONS & LIMITATIONS TECHNICAL INFORMATION

• Always add powder to liquid. Do not add water into the


Observations /
mixture. Properties Specification
Results
• In case of patch application, extend the application atleast
2 feet beyond the affected area to cover the surrounding Mixing ratio (Liquid : Powder) 1:2 ---
regions effectively.
• Do not conduct ponding test till the coating is cured for 7 Surface dry time 40 - 50 mins ASTM C 1640
days.
• Ensure that the freshly plastered surface or new masonry Recoatable time 4 - 6 hours ASTM C 1640
surface is completely cured for at least 28 days. In case of
replastering, plaster must be cured for at least 7 days Pot Life@27ºC Min 45 mins ---
• Application is not to be done in rainy/high humid (> 80%
relative humidity) season or in extreme cold temperatures Dry Film Thickness 1 mm ASTM D 1005
(less than 10°C) or if the temperature might drop to this level
within 4 hours of application. up to 100 ASTM D 2370
% Elongation at break
• Mixed product should be used within 4 hours of dilution. It is
recommended to mix only the necessary amount and
Tensile strength 0.9 N/mm2 ASTM D 2370
consume it fully.
• Ensure that terrace surface has adequate slope to avoid
Positive Hydrostatic Pressure up to 5 bar EN12390-8
water accumulation.
• All corners, gaps, joints, roof leak repair area and outlets
Negative Hydrostatic Pressure up to 4 bar ASTM D 7088
shall be coated with extra coat.
• Keep the material closed when not in use.
Crack Bridging ability Upto 1.2 mm EN 1062-7(A)
• The Product when applied on horizontal exterior surfaces
need to be covered with screed. as mentioned above in
"Mixing & Application" steps. Pull off adhesion strength Upto 1 mpa ASTM D 7234

Food grade certification POTABLE (As per US FDA


WATER SAFE* – 175.300)

Version No. C2K-1001/08/2024


*T&C Apply. For more details visit [Link]. Please refer to the product warranty document for further details.