0% found this document useful (0 votes)
225 views8 pages

Pile Cap Design Calculations

This document provides the design of a pile cap. Key details include: - Maximum column load of 80,000 lbs originally, then 200,000 lbs - Pile bearing capacity of 20,000 lbs/pile and 116,000 lbs/pile - 5 piles originally required, then 2 piles - Pile cap sizing of 6.75 ft x 6.75 ft originally, then 8 ft x 4 ft - Reinforcement includes #4 bars at 6 in c/c originally

Uploaded by

Shafayet Ullah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
225 views8 pages

Pile Cap Design Calculations

This document provides the design of a pile cap. Key details include: - Maximum column load of 80,000 lbs originally, then 200,000 lbs - Pile bearing capacity of 20,000 lbs/pile and 116,000 lbs/pile - 5 piles originally required, then 2 piles - Pile cap sizing of 6.75 ft x 6.75 ft originally, then 8 ft x 4 ft - Reinforcement includes #4 bars at 6 in c/c originally

Uploaded by

Shafayet Ullah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd

Name of Project:

Name of Client: Design by: [Link] Ahmmed


DagonBhuiyan,feni, Phone 01670490920

DESIGN OF PILE CAP

INPUT DATA:
Maximum column Load P= 80,000 Lb
Bearing Capacity of Pile q= 20,000 LBS/PILE
Size of Column Width 18 Inch
Short side 18 Inch
Ultimate Strength of steel fy = 40000 psi
Ultimate Stress of Concrete fc' = 2,500 psi
Working Stress of Steel fs = 18,000 psi
Working Stress of Concretel fc = 1,125 psi
Shearing stress vc = 55 psi
Peripheral shearing stress vp = 100 psi
Unit wt. of Concrete w= 150 psf
Pile Diameter 18 Inch

Ec= w1.5x33Öfc' k= n/(n+r)


Ec= 3,031,244 PSI k= 0.374
Es= 2.90E+07 psi j= 1- k / 3
n= Es/Ec j= 0.875
n= 10 R= 1/2 fc j k
r= fs/fc R= 184
r= 16

DESIGN :
Weigth of the footing= 10 % of column Wt.)
Weigth of the footing= 8000 Lb
Estimated Design Weigth of the footing P1= 80,000+8,000
P1 = 88000 Lb
Number of pile required = 88,000/20,000
= 4.40 Nos.
Provided No of pile = 5 Nos.
Center to center spacing of piles S = 3 ft 80000 Lb
Distance from C/L of pile to the face of fotting= 1.25 ft 18 18
Width of footing B/L = 3.00+2.50 ft
B/L = 5.5 ft 16.00
Provided size of Footing 16000 1.375
B= 6.75 ft
L= 6.75 ft 6.75ft
Provided area of Footing, A= 45.56 ft2
The net upward pressure per pile
w= P/N
= 80,000 / 4 6.75ft
w= 16,000 lb
Bending Moment at the face of M= 2wc
= 2x16,000x1.375 0.29
M= 528000 Lb-inch
The minimum effective depth, d= ÖM/Rb
= SQRT(528,000/184x81)
d= 5.95 inch
Provided effective depth, d= 13.00 inch
Shearing StressChecking, v= V/bd Shearing stress is critical at a distance "d" from
= 32,000/81x13 the face of column
v= 30.39 psi Maximum shear,V= 16,000x2
Shear Check Ok V= 32000 Lb

Punching Shearing Stress Checking Punching Shear is critical at a distance "d/2" from
v= V/bod the face of column
= 64,000/124.0x13.0 Maximum shear,V= 4x16,000
v= 39.70 psi V= 64000 Lb
Shear Check Ok bo= 2x(31.00+31.00)
bo= 124.00 inch
Punching Shearing Stress Checking
v= V/bod V= 16000.00
= 16,000/56.55x13.00 b= 56.55 inch
v= 21.76 psi
Shear Check Ok
Tesile Reinforcment: As=M/fsjd
As= 528,000/18,000x0.875x13.0
As= 2.578 inch2
Provide # 4 bar
Spacing of reinforcement, S= (X-Sectional Area of Provided bar x 12xB) / As
S= 0.20x6.75x12/2.578
S= 6 inch C/C
So provide # 4 6.75 inch C/C
Total Number of reinforcing bar (B*12-6)/S +1
n= #VALUE!
n= #VALUE! nos
The perimeter of # 4
= 1.57 inch
The Bond stress u= V/åojd Maximum shear,V= 16,000.00x2
u= #VALUE! V= 32000 Lb
u= #VALUE! psi
Name of Project:
Name of Client: Design by: Engr. Masud Ahmmed
DagonBhuiyan,feni, Phone 01670490920

DESIGN OF PILE CAP

INPUT DATA:
Maximum column Load P= 200,000 Lb
Bearing Capacity of Pile q= 116,000 LBS/PILE
Size of Column, width 10 Inch
depth 18 Inch
Ultimate Strength of steel fy = 72000 psi
Ultimate Stress of Concrete fc' = 3,500 psi
Working Stress of Steel fs = 32,400 psi
Working Stress of Concretel fc = 1,575 psi
Shearing stress vc = 65 psi
Peripheral shearing stress vp = 118 psi
Unit wt. of Concrete w= 150 pcf
Pile Diameter 18 Inch

Ec= w1.5x33Öfc' k= n/(n+r)


Ec= 3,586,616 PSI k= 0.282
Es= 29,000,000 psi j= 1- k / 3
n= Es/Ec j= 0.906
n= 8 R= 1/2 fc j k
r= fs/fc R= 201
r= 21

DESIGN :
Weigth of the footing= 10 % of column Wt.)
Weigth of the footing= 20000 Lb
Estimated Design Weigth of the footing P1= 200,000+20,000
P1 = 220000 Lb
Number of pile required = 220,000/116,000=
= 1.90 Nos.
Provided No of pile = 2 Nos.
Center to center spacing of piles S = 4 ft 200000 Lb
Distance from C/L of pile to the face of fotting= 2 ft 10 18
Width of footing B/L = 4.00+4.00 ft
B/L = 8 ft 23.00 inchs
Provided size of Footing 100000 1.583
B= 8.00 ft
L= 4.00 ft 8.00
Provided area of Footing, A= 32.00 ft2
The net upward pressure per pile
w= P/N 4.00 ft
= 200,000 / 2
w= 100,000 lb
Bending Moment at the face of M= wc -0.08
= 100,000x1.583
M= 1,900,000.00 Lb-inch Note: Shear Check Not Required
The minimum effective depth, d= ÖM/Rb
= SQRT(1,900,000/201x48.00)
d= 14.02 inch
Provided effective depth, d= 20.00 inch
Shearing StressChecking, v= V/bd Shearing stress is critical at a distance "d" from
= 100,000/48x20 the face of column
v= 104.17 psi Maximum shear,V= 100,000 lb
Sheas Check Not Ok

Punching Shearing Stress Checking for Column Punching Shear is critical at a distance "d/2"
v= V/bod from the face of column
= 100,000/136.00x20.0 Maximum shear
v= 36.76 psi V= 100000 Lb
Shear Check Ok bo= 2x(30.00+38.00)
bo= 136.00 inch
Punching Shearing Stress Checking for Pile
v= V/bod V = 100000.00
= 100,000/56.55x20.00 b= 56.55 inch
v= 88.42 psi
Shear Check Ok
Tesile Reinforcment: As=M/fsjd
As= 1,900,000/32,400x0.906x20.0
As= 3.236 inch2 10.419355
Provide # 11 bar
Spacing of reinforcement, S= (X-Sectional Area of Provided bar x 12xB) / As
S= 1.48x8.00x12/3.236
S= 43.9043 inch C/C
So provide # 11 8 inch C/C
Total Number of reinforcing bar (B*12-6)/S +1
n= (8.00x12-6)/8+1
n= 12 nos
The perimeter of # 11
= 4.32 inch
The Bond stress u= V/åojd Maximum shear,V= 100,000.00x2
u= 200,000/12x4.32x0.906x20.00 V= 200000 Lb
u= 209 psi
Name of Project:
Name of Client: Design by: Engr. Masud Ahmmed
Dagonbhuiyan,feni, Phone 01670490920

DESIGN OF PILE CAP

INPUT DATA:
Maximum column Load P= 80,000 Lb
Bearing Capacity of Pile q= 45,000 LBS/PILE
Size of Column, width 18 Inch
depth 18 Inch
Ultimate Strength of steel fy = 40000 psi
Ultimate Stress of Concrete fc' = 2,500 psi
Working Stress of Steel fs = 18,000 psi
Working Stress of Concretel fc = 1,125 psi
Shearing stress vc = 55 psi
Peripheral shearing stress vp = 100 psi
Unit wt. of Concrete w= 150 psf
Pile Diameter 18 Inch

Ec= w1.5x33Öfc' k= n/(n+r)


Ec= 3,031,244 PSI k= 0.374
Es= 29,000,000 psi j= 1- k / 3
n= Es/Ec j= 0.875
n= 10 R= 1/2 fc j k
r= fs/fc R= 184
r= 16

DESIGN :
Weigth of the footing= 10 % of column Wt.)
Weigth of the footing= 8000 Lb 80,000 lb
Estimated Design Weigth of the footing P1= 80,000+8,000 18 18
P1 = 88000 Lb
Number of pile required = 88,000/45,000=
= 1.96 Nos.
Provided No of pile = 2 Nos.
Center to center spacing of piles S = 3 ft
Distance from C/L of pile to the face of fotting= 1.25 ft
Width of footing B/L = 3.00+2.50 ft 5.5ft
B/L = 5.5 ft
Provided size of Footing 3
B= 5.50 ft
L= 3.00 ft
Provided area of Footing, A= 16.50 ft2

Length of AB=AC=BC= 3 ft 3ft


Length of CD= 2.60 ft
Length of CE= 1.73 ft
Length of DE= 0.87 ft 80,000
DESIGN OF BEAM CD 3ft
C D A
E B
Rc= 26,666.67 53,333.33 =Rd D
E
Max bending moment = 46,188.09 lb ft
Use over all depth of Beam= 15 inch
Self wt of beam= 843.75 lb/ft
Moment due to self wt.= 632.81 lb ft
Total moment= 46,820.90 lb ft C
d= 13.02
use 6 # dia bar
Area = 0.44 t= 17.14 inch
use 18 inch
d= 13.88 inch
As= 2.57 in2
No of bar required= 5.82 no
Provide 6
53,333.33 lb
DESIGN OF BEAM AB
A B
1.5
27,932.29 lb 27932.29 lb

Mid span moment = 40949.22 lb ft


d= 13.77 inch
As= 2.27 in2
No of bar required= 5.13 no
Provide = 6

Secondary Reinforcement:
Area of S.R. around Pile= 0.514 in2
Provide = 3 # bar
Area = 0.11 in2
No of bar required = 4.65 no
Provide = 5 no
ne 01670490920