0% found this document useful (0 votes)
336 views56 pages

Sensors: Product Product Code Technical Instructions Page # Temperature Sensors

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
336 views56 pages

Sensors: Product Product Code Technical Instructions Page # Temperature Sensors

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Distributed By: M&M Control Service, Inc. [Link]/siemens.

php 800-876-0036 847-356-0566

Sensors

Table of Contents

Product Product Code TECHNICAL INSTRUCTIONS Page #

Temperature Sensors

10K NTC/1K Platinum RTD Room Temperature Sensors Series 1000 149-312 B-3

100K NTC Room Temperature Sensors Series 1000 149-168 B-5

Flush Mount Room Temperature Sensors 536/540/544 Series 149-971 B-7

Button Room Temperature Sensors QAA Series 149-471 B-9

Temperature Room Units for Third-Party Systems Series 2300 149-710 B-11

Room Temperature Sensors QAA20 Series 149-912/913/914 B-13

Duct, Pipe and Outdoor Air Temperature Sensors QAx20 Series 149-915 B-15

4 to 20 mA Analog Sensors 533/535/536/544 Series 149-263P25 B-17

Humidity Sensors

Room Relative Humidity and Temperature


Room Units for Third-Party Systems Series 2300 149-103 B-19

Room Relative Humidity


and Temperature Sensors QFA Series 1000 149-479 B-21

Room/Outside Air Relative Humidity


and Temperature Sensors QFA Series 149-992 B-23

Duct Relative Humidity


and Temperature Sensors QFM Series 149-991 B-25

Pressure Sensors

Very Low Differential Pressure Transducers 590 Series 149-957 B-27


Pressure Sensors for Liquid and Gas 7MF Series 7MF1564 B-29

Pitot Tube Sensor Kits 536 Series 149-455 B-31

CO2/VOC/Gas Sensors

Room Carbon Dioxide/VOC/Temp/RH Sensors QPA Series 149-910 B-33

Duct Carbon Dioxide/VOC/Temp/RH Sensors QPM Series 149-909 B-35

Specialty Sensors

Air Velocity Sensor QVM62.1 149-007 B-37

Solar Impact Sensor QLS60 155-706 B-39

Liquid Flow Switches QVE Series 155-778/155-711 B-41

Condensation Sensor QXA2000 149-926 B-43


Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

Product Product Code TECHNICAL INSTRUCTIONS Page #

Relative Humidity Hygrostats

Electronic Room Hygrostats QFA Series 155-708 B-45

Electronic Duct Hygrostats QFM Series 155-707 B-47

Pneumatic Room and Duct Hygrostats 186 Series 155-025P25 B-49

Accessories and Service Kits B-51

Sensor Compatibility Matrix


B-2

Triangle Microsystems
Anderson Cornelius

Schneider General
Reliable Controls
Automated Logic

Distech Energie
Delta Controls
Sensors

Auto-Matrix

Honeywell
Invensys

Solidyne
Andover

TAC/CSI
Teletrol
Alerton

Carrier

Walker
Circon

Trane
KMC

York
T&A
AET

JCI

Signal Type
0 to 10 Vdc               •
1K Platinum RTD
B-1                         •             •        
(375 element)
1K Platinum RTD
                    • • •             •        
(385 element)
4 to 20 / 0 to 20 mA               •                                
Ni1000 RTD (JCI)                         •                   •  
Ni1000 RTD (L&S)                                                
NTC 10K (Type II)   •     •   •     •     • •     • •   • •      
NTC 10K (Type III) •     •   • •   •     •   • •       •       •  
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

Series 1000

Room Temperature Sensors


– For Siemens APOGEE® Field Panels and Controllers

Series 1000 Room Temperature Sensor


with all Available Options.

Description Applications
B-3
The Series 1000 Room Temperature Sensors offer a wide These sensors may be installed in all kinds of
range of features and functionality that deliver exceptional environments including schools, hospitals, universities,
occupant comfort in even the most demanding application strip malls and commercial office buildings.

Sensors
environments. The product family range includes plain
sensing only variants, as well as types with temperature
setpoint LCD display and night set back. All sensors
incorporate precision temperature sensing elements to
accurately and reliably measure room temperature. Their
compact design results in an attractive, inconspicuous
installation. A styled ventilation ring optimizes airflow
through the cover for fast measurement response and
superior control.

Features
• Platinum RTD or thermistor element
• Variety of connections
• Unpluggable termination block simplifies installation
and service
• Plug in terminal for troubleshooting
• Maintenance free

Optional
• LCD temperature display
• Setpoint adjustment
• Occupancy override button
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

Series 1000 Room Temperature Specifications

Temperature Range Installation


Setpoint.............................................................. 55 to 95°F (13 to 35°C) TEC .......................................................100 ft. Maximum Cable Length
Operating........................................................... 55 to 95°F (13 to 35°C) 6C # 24 AWG, Belden 1228A or Equal, NEC Class 2
Output Signals......................................................... Changing Resistance APOGEE Field Panels........................................................300 to 750 ft.
Accuracy Max. Cable Length 18 to 22 AWG
10K Ohm Thermistor Twisted Pair, NEC Class 2
55 to 80.6°F (13 to 27°C).......................................... ±0.5°F (±0.3°C) Installation Adjustments................................................... None Required
80.6 to 95°F ( 27 to 35°C)......................................... ±1.0°F (±0.5°C) Cover Dimensions.................................. 3-11/32" H x 2-1/2" W x 1-1/2" D
1,000 Ohm RTD Mid-Range (85 mm x 63 mm x 38 mm)
75°F (24°C)............................................................ ±0.75°F (± 0.4°C)
Cover Color............................................................. Desert Beige or White
Calibration Adjustments................................................... None Required

Series 1000 Room Temperature Ordering


Description Part No.
10K NTC
Sensing Only 540-6601
Sensing with Override, Setpoint 540-6701
Sensing with Override, Setpoint, Temperature and Display 540-6802
B-4 1K Platinum RTD Type (375 ALPHA)
Sensing Only 544-7601
Sensing with Override, Setpoint 544-7701
Sensors

Sensing with Override, Setpoint, Temperature Display 544-7802


Ordering Notes:
Add letter suffix to indicate desired color: A for Desert Beige, B for White (Example: 540-660A).
1

Add letter suffix to indicate temperature display units and color:


2

F for °F, C for °C, A for Desert Beige, B for White (Example: 540-680FA).

B-1
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

Series 1000

100K NTC and 4 to 20 mA


Room Temperature Sensors

Siemens 4 to 20 mA and 100K Ohm


Room Temperature Sensor.

Description
B-5
The miscellaneous Room Temperature Sensors provide
accurate 100K NTC, reliable sensing of room temperature.
The sensor’s resistance varies proportionally to the

Sensors
actual room temperature being measured.
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

100K NTC and 4 to 20 mA Room Temperature Sensors Specifications

Temperature Range Calibration Point Factory Setting............................................. 77°F (25°)


Setpoint.............................................................. 55 to 95°F (13 to 35°C) Accuracy........................................................................ ±0.5°F (±0.3°C)
Operating .......................................................... 55 to 95°F (13 to 35°C) Resistance Value...................................................................... 10K Ohm
Output Signal........................................................... Changing Resistance Calibration Adjustments................................................... None Required
.................................................................................. or 4 to 20 mA Cover Dimensions..................................... 3-11/32"H x 2-1/2"W x 1-1/2"D
(85 mm H x 64 mm W x 38 mm D)

100K NTC and 4 to 20 mA Room Temperature Sensors Product Ordering


Application Temperature Range Desert Beige Part No. White Part No.
Room 100K Ohm 20°F to 120°F (-7°C to 49°C) 536-983A 536-983B
Room 4 to 20 mA 40°F to 90°F (-5°C to 32°C) 536-752A 536-752B
Room 4 to 20 mA 20°F to 120°F (-6°C to 48°C) 536-753A 536-753B

Ordering Notes:
The controller to which the sensor is connected determines application-sensing range.


B-6
Sensors

B-1
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

536/540/544 Series

Flush Mount
Room Temperature Sensors

Plastic Flush Mount Room Metal Flush Mount Room


Temperature Sensor. Temperature Sensor.

Description Applications
B-7
The Flush Mount Room Temperature Sensor provides The Flush Mount Room Temperature Sensor is
sensing of room temperature to the Siemens room designed for those applications in which a protruding
controller products. The sensor’s resistance varies with the room temperature sensor is not acceptable.

Sensors
actual room temperature being measured.
The sensor connects to the controller via a 2-wire pigtail
connection. It incorporates a temperature-sensing element
(10K Ohm Type II thermistor, 100K Ohm thermistor, or
1000 Ohm RTD) behind a blank, stainless steel or plastic
switch cover plate.

Features
• Tamper-proof screws
• Can be painted after installation
• Designed for mounting to a 2 x 4 electrical box
• Option of brushed stainless steel finish or beige
or white plastic
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

Flush Mount Room Temperature Sensors Specifications

Output Signal........................................................... Changing Resistance 1000 Ohm RTD


Operating Temperature Range*.................-40 to +257°F (-40 to +120°C) Calibration Point ........................................................................... 32°F (0°)
Accuracy...................................................................... ±0.54°F (±0.3°C)
10K Ohm Thermistor Resistance Value @ Cal. Temp.................................................. 1K Ohm
Calibration Point Factory Setting................................................. 77°F (25°)
Accuracy........................................................................ ±0.5°F (±0.3°C) Dimensions...............................................4-1/2" H x 2-3/4" W x 1-1/36" D
Resistance Value @ Cal. Temp..........................................................10k (114 mm H x 70 mm W x 27 mm D)
100K Ohm Thermistor *Functional range is controller dependent.
Calibration Point ......................................................................... 77°F (25°)
Accuracy........................................................................ ±0.5°F (±0.3°C)
Resistance Value @ Cal. Temp...............................................100k Ohm

Flush Mount Room Temperature Sensors Product Ordering


Description Part No.
10K Ohm (APOGEE TEC) NTC Thermistor, Metal Plate 540-995
10K Ohm (Type II) NTC Thermistor, Metal Plate 540-984
10K Ohm (Type II) NTC Thermistor, Beige Plastic Plate 536-994A
10K Ohm (Type II) NTC Thermistor, White Plastic Plate 536-994B
100K Ohm NTC Thermistor, Metal Plate 536-984
1000 Ohm (375 ALPHA) Platinum RTD, Metal Plate 544-973

B-8 1000 Ohm (375 ALPHA) Platinum RTD, Beige Plastic Plate 544-374A
1000 Ohm (375 ALPHA) Platinum RTD, White Plastic Plate 544-374B
Sensors

B-1
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QAA Series

Button Room Temperature Sensors

Button Room Temperature Sensor


(with or without Wall Plate).

Description Applications
B-9
The Button Room Temperature Sensor provides a This room sensor is designed for applications in which
resistance signal to the Siemens controller that varies a normal or flush-mount room temperature sensor is
proportionally with temperature. not acceptable. It is available with or without a brushed,

Sensors
stainless steel wall plate.
The sensor connects to the controller via a two-wire field
cable or pre-terminated cable with RJ-11 plugs. The Button The wall plate version is designed to mount to a 2-inch
Room Temperature Sensor has a temperature-sensing x 4-inch electrical box. The tamper-proof screws, used to
element (10K ohm Thermistor [TEC compatible only], or install the sensor to the utility box, protect the sensor from
1000 ohm RTD, 375 alpha) installed on the button sensor. removal by unauthorized personnel.

Features
• 10K NTC for TEC or 1K platinum (375) RTD Sensors
• Tamper-proof screws
• Can be painted after installation
• Designed for mounting to a 2 x 4 electrical box
• Brushed stainless steel finish
• Available with or without matching wall plate
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

Button Room Temperature Sensors Specifications

Output Signal........................................................... Changing Resistance 1000 Ohm RTD


10K Ohm Thermistor Operating Temperature Range*........................ -40 to 257°F (-40 to 125°C)
Operating Temperature Range*.............................. 55 to 95°F (13 to 35°C) Calibration Point......................................................................... 32°F (0°C)
Calibration Point....................................................................... 77°F (25°C) Accuracy...................................................................... ±0.54°F (±0.3°C)
Accuracy........................................................................ ±0.5°F (±0.3°C) Resistance Value........................................................................ 1K Ohm
Resistance Value...................................................................... 10K Ohm Dimensions...............................................4-1/2" H x 2-3/4" W x 1-1/36" D
...........................................................(114 mm x 70 mm x 27 mm)
*Functional range is controller dependent.

Button Room Temperature Sensors Product Ordering


Description Part No.
1K Platinum (375) RTD [Link]
1K Platinum (375) RTD, with Wall Plate [Link]

B-10
Sensors

B-1
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

Series 2300

Temperature Room Units


For Third-party Systems

[Link]
Temperature Room Unit with Analog [Link]
Display, Setpoint and Override. Temperature Room Unit.

Description Applications
B-11
Series 2300 Temperature Room Units offer simple These room units connect to the controllers input points
temperature sensing functionality. These devices work via free wire cabling, which is landed on the controllers’
with third party systems to deliver exceptional occupant terminal block connector.

Sensors
comfort. All room units incorporate precision temperature
sensing elements to accurately and reliably measure room
temperature. Their compact, low-profile design results
in an attractive, inconspicuous installation. Strategically
placed ventilation slots in the housing optimize airflow
through the cover for fast measurement response and
superior control.

Features
• Resistive output signals
• Selectable voltage or current output models
• High degree of accuracy
• Analog temperature display
• Organic light emitting diode
• Analog setpoint adjustment
• Occupancy override button
• Dim or brighten display
• Show or hide OLED display elements
• Local setpoint limiting
• Numerical or graphical display of temperature setpoint
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

Series 2300 Specifications

Temperature Range Installation


Setpoint and Operating………............................55F to 95°F (13C to 35°C) NTC Types..................................................100 ft. Maximum Cable Length.
Output Signals……………………........................... .Changing Resistance ..................... 6C #24 AWG, Belden 1228A or Equal, NEC Class 2
Sensing Element Type RTD Types.......................................300 to 750 ft. Maximum Cable Length.
QAA2312 Types ..................................................1K ohm Platinum RTD ..................................... 18 to 22 AWG, Twisted Pair, NEC Class 2
QAA2320 Types ........................................1K Ohm Nickel RTD @ 32°F Installation Adjustments................................................... None Required
QAA2321 Types ........................................1K Ohm Nickel RTD @ 70°F
QAA2330 Types ................................ 10K Ohm NTC Type II Thermistor Cover
QAA2332 Types .............................. .10K Ohm NTC Type III Thermistor Dimensions…………………………………................ 4.5" × 2.75" × 1.18"
QAA23SS Types ................................. 0-10V/0-5V/4-20 mA Selectable .......................................................... (115 mm × 70 mm × 30 mm)
Color .............................................................................................. White
Accuracy
10K Ohm Thermistor
55° - 80.6°F (13°C - 27°C)........................................ ±0.5°F (±0.3°C) Regulatory Agency........................................................................ UL 916
80.6° - 95°F (27°C - 35°C)........................................ ±1.0°F (±0.5°C)
1K Ohm RTD Mid-Range
75°F (24°C)............................................................ ±0.75°F (± 0.4°C)

Series 2300 Product Ordering


Description Part No.
1K Platinum RTD Sensors (385 ALPHA)
Sensing, No Logo [Link]
Sensing, Digital Display, Setpoint Adjustment, Override, No Logo [Link]
B-12 Warmer/Cooler Setpoint Adjustment, Bi-metallic Display, No Logo [Link]
1K Nickel RTD Sensors @ 32°F
Sensing, No Logo [Link]
Sensing, Digital Display, Setpoint Adjustment, Override, No Logo
Sensors

[Link]
Override, Warmer/Cooler Setpoint Adjustment, Bi-metallic Display, No Logo [Link]
1K Nickel RTD Sensors @ 70°F
Sensing, No Logo [Link]
Sensing, Digital Display, Setpoint Adjustment, Override, No Logo [Link]
Override, Warmer/Cooler Setpoint Adjustment, Bi-metallic Display, No Logo [Link]
10K NTC Type II Thermistor Sensor
B-1
Sensing, No Logo [Link]
Sensing, Digital Display, Setpoint Adjustment, Override, No Logo [Link]
Override, Warmer/Cooler Setpoint Adjustment, Bi-metallic Display, No Logo [Link]
10K NTC Type III Thermistor Sensor
No Logo, Sensing [Link]
Sensing, Digital Display, Setpoint Adjustment, Override, No Logo [Link]
Override, Warmer/Cooler Setpoint Adjustment, Bi-metallic Display, No Logo [Link]
0-10V/0-5V/4-20 mA Selectable Temperature Sensor
Sensing, No Logo [Link]
Digital Display, Temperature Setpoint, Override, No Logo [Link]

Series 2300 Accessories Ordering Information


Description Part No.
Replacement Sensor Housing Base (For .E Models Only) 563-102-02
Replacement Sensor Housing Base (For .B Models Only) 563-102-03
Room Unit Back Plate (10-Pack) AQA2200-INTL

Accessories & Service Kits B-51


Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QAA20 Series

Room Temperature Sensors

[Link]
Room Temperature Sensor with [Link]
Analog Display, Setpoint and Override. Room Temperature Sensor.

Description Applications
B-13
The QAA20 Series Room Temperature Sensors monitor The QAA20 Series Room Temperature Sensors are
and transmit changes in temperature to the building especially suited for applications where precise, stable
control systems. QAA20 Series sensors utilize the temperature sensing is required. An assortment of models

Sensors
standard Series 1000 housing, but with a totally new is available – versions with sensing only or setpoint
internal circuit design. adjustment, occupancy override and display.

Features The QAA20 Series temperature sensors are also available


in a variety of signal types. Choose from powered 4 to
• Resistive output signals 20 mA or 0 to 10 Volt signal versions. Choose also from
• High degree of accuracy numerous resistive signal outputs. Select the correct
product based on the compatibility needs of your building
• Analog temperature display automation system. See the Sensor Compatibility Matrix
• Liquid Crystal Display (LCD) on page B-2 for more details.
• Analog setpoint adjustment
• Occupancy override button
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QAA20 Series Specifications

General Temperature Element


Installation................................. 18 AWG Cable Length Shared in Conduit Measurement Range............................................... Controller Dependent
with Other Sensor Wiring 750 ft. (229 m) max. Operating Temperature.................................. -40 to 240°F (-40 to 116°C)
Connections .................................................................... Screw Terminals Operating Range, Active Signal Types....................................40 to 90°F
Voltage Requirement.................................................... 13.5 to 35 Vdc and Temperature Effect..................................... Less than 0.1% per Degree C
24 Vac (for Sensors with 0-10 Vdc outputs)
Sensing Element................................................Various,See Table Below
Housing
Output Signals
Material Type.........................................................Polycarbonate Plastic
Resistive Types............................................................................Various
Color .............................................................................................. White Active Types................................................ 4 to 20 mA and 0 to 10 Vdc,
Dimensions.......................................... 3-11/32" H x 2-1/2" W x 1-1/2" D 0-100% Linear, Proportional
(85 mm H x 63 mm W x 38 mm D) Polarity Protection...............................................................................Yes
Accuracy at Calibration Temperature............................................+/- 1 K

QAA20 Series Product Ordering


Description Part No.
Nickel RTD Sensors
1000 Ohms @ 32°F, Setpoint, Night Override, Display, No Logo [Link]
1000 Ohms @ 77°F, No Logo [Link]
1000 Ohms @ 77°F, Setpoint, Night Override, Display, No Logo [Link]
NTC Thermistor Sensors
B-14
1000 Ohms @ 77°F, No Logo [Link]
4 to 20 mA Sensors
40 to 90°F, No Logo [Link]
Sensors

40 to 90°F, Siemens Logo [Link]


40 to 90°F, Setpoint, Night Override, Display, No Logo [Link]
40 to 90°F, Setpoint, Night Override, Display, Siemens Logo [Link]
0 to 10 Volt Sensors
40 to 90°F, No Logo [Link]
40 to 90°F, Siemens Logo [Link]
B-1 40 to 90°F, Setpoint, Night Override, Display, No Logo [Link]
40 to 90°F, Setpoint, Night Override, Display, Siemens Logo [Link]

Accessories & Service Kits B-51


Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QAx20 Series

Duct, Pipe, Outdoor Air Temperature Sensors

QAC20xxU [Link] [Link]


Outside Air Sensor. 8-inch Duct Point Temperature Sensor. Averaging Flexible Thermistor Sensor.

[Link] QAD20xxU [Link]


Duct (Single Point) Thermistor Sensor. Surface Mounted Pipe Sensor. Liquid Immersion Thermistor Sensor.

Description Applications
B-15
The QAx20 Series Duct, Pipe and Outdoor Air Temperature The QAx20 Series Duct, Pipe and Outdoor Air Temperature
Sensors monitor and transmit changes in temperature to Sensors are especially suited for applications where
the building control systems. precise, stable temperature sensing is required. These

Sensors
sensors are available in a variety of signal types. Choose
Features from numerous resistive signal outputs, and select
the correct product, based on the compatibility needs
• Resistive output signals of your building automation system. See the Sensor
• High degree of accuracy Compatibility Matrix on page B-2 for more details.
• 2 x 4 or metal box enclosure

Specifications

General Temperature Element


Installation.................................... 18 AWG cable length shared in conduit Measurement Range............................................... Controller Dependent
with other sensor wiring 750 ft. (229 m) max Operating Temperature.................................. -40 to 240°F (-40 to 116°C)
Connections .................................................................... Screw Terminals Sensing Element..................... Various Resistive Types, see Naming Key
Polarity Protection...............................................................................Yes
Accuracy at Calibration Point........................................................+/- 1 K
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QAx20 Series Product Ordering


Application Description Part No.
Outdoor Air Sensor PT 1000 Ohm (385), Metal Housing QAC2012U
Outdoor Air Sensor NI 1K Ohm @ 32°F, Metal Housing QAC2020U
Outdoor Air Sensor NI 1K Ohm @ 77°F, Metal Housing QAC2021U
Outdoor Air Sensor NTC 10K Ohm Type 2, Metal Housing QAC2030U
Outdoor Air Sensor NTC 10K Ohm Type 3, Metal Housing QAC2032U
Outdoor Air Sensor PT 1000 Ohm (385), Polycarbonate Housing QAC2012
Outdoor Air Sensor NTC 10K Ohm Type 2, Polycarbonate Housing QAC2030
Outdoor Air Sensor 0-10 Vdc Ohm Type 2, Polycarbonate Housing QAC3161
Outdoor Air Sensor 4-20 mA, Polycarbonate Housing QAC3171
Duct Point Sensor PT 1K Ohm, (385), 4 Inch QAM2012.010
Duct Point Sensor PT 1K Ohm, (385), 8 Inch QAM2012.020
Duct Point Sensor PT 1K Ohm, (385), 18 Inch QAM2012.045
Duct Point Sensor PT 1K Ohm, (385), 8 Foot QAM2012.250
Duct Point Sensor PT 1K Ohm, (385), 16 Foot QAM2012.500
Duct Point Sensor PT 1K Ohm, (385), 24 Foot QAM2012.750
Duct Point Sensor NI 1K Ohm @ 32°F, 4 Inch QAM2020.010
Duct Point Sensor NI 1K Ohm @ 32°F, 8 Inch QAM2020.020
Duct Point Sensor NI 1K Ohm @ 32°F, 18 Inch QAM2020.045
B-16 Duct Averaging Sensor NI 1K Ohm @ 32°F, 16 Foot QAM2020.500
Duct Averaging Sensor NI 1K Ohm @ 32°F, 24 Foot QAM2020.750
Duct Point Sensor NI 1K Ohm @ 77°F, 8 Inch QAM2021.020
Sensors

Duct Point Sensor NI 1K Ohm @ 77°F, 18 Inch QAM2021.045


Duct Averaging Sensor NI 1K Ohm @ 77°F, 24 Foot QAM2021.750
Duct Point Sensor NTC 10K Ohm Type 2, 4 Inch QAM2030.010
Duct Point Sensor NTC 10K Ohm Type 2, 8 Inch QAM2030.020
Duct Point Sensor NTC 10K Ohm Type 2, 18 Inch QAM2030.045
Duct Averaging Sensor NTC 10K Ohm Type 2, 8 Foot QAM2030.250

B-1 Duct Averaging Sensor NTC 10K Ohm Type 2, 16 Foot QAM2030.500
Duct Averaging Sensor NTC 10K Ohm Type 2, 24 Foot QAM2030.750
Duct Point Sensor NTC 10K Ohm Type 3, 4 Inch QAM2032.010
Duct Point Sensor NTC 10K Ohm Type 3, 8 Inch QAM2032.020
Duct Point Sensor NTC 10K Ohm Type 3, 18 Inch QAM2032.045
Duct Averaging Sensor NTC 10K Ohm Type 3, 8 Foot QAM2032.250
Duct Averaging Sensor NTC 10K Ohm Type 3, 16 Foot QAM2032.500
Duct Averaging Sensor NTC 10K Ohm Type 3, 24 Foot QAM2032.750
Strap-on Pipe Sensor PT 1K Ohm (385 Alpha), Polycarbonate Housing QAD2012
Strap-on Pipe Sensor NTC 10K Ohm Type II, Polycarbonate Housing QAD2030
Surface Mounted Pipe Sensor PT 1K Ohm RTD (385 Alpha), Metal Housing QAD2012U
Surface Mounted Pipe Sensor NTC 10K Ohm Type II, Metal Housing QAD2030U
Surface Mounted Pipe Sensor NTC 10K Ohm Type 3, Metal Housing QAD2032U
Surface Mounted Pipe Sensor NI 1K Ohm (at 32°F), Metal Housing QAD2020U
Surface Mounted Pipe Sensor NI 1K Ohm (at 70°F), Metal Housing QAD2021U
Liquid Immersion Sensor* PT 1K Ohm (385); xxx= 010 (4") or 015 (6") [Link]
Liquid Immersion Sensor* NTC, 10K Ohm Type 2; xxx=010 (4") or 015 (6") [Link]
Liquid Immersion Sensor* 0-10 Vdc; xxx= 010 (4") or 015 (6") [Link]
Liquid Immersion Sensor* 4-20 mA; xxx=010 (4") or 015 (6") [Link]

*Liquid Immersion Sensors require ARG150U (6" immersion well) or ARG100U (4" immersion well), sold separately.
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

533/535/536/544
Series
4 to 20 mA Analog Sensors

Surface Mounted Outside Air Duct (Single Point)


Pipe Sensor. Temperature Sensor. Temperature Sensor.

Duct (Averaging) Duct (Averaging) Duct Liquid Immersion


Flexible Temperature Sensor. Rigid Temperature Sensor. Temperature Sensor.

Description Applications
B-17
Available in a variety of models for specific mounting Analog Sensors are designed for a variety of temperature
requirements and sensing applications, Analog Sensors sensing applications including room, surface-mount,
provide input for accurate loop-powered temperature outside air, duct point or averaging, and liquid immersion

Sensors
sensing (detecting) for controllers via a 20 AWG twisted, where high accuracy and/or long wiring runs are required.
shielded cable pair. The loop current varies according to
Important: Sensors are not suitable for use with Siemens
the temperature being measured.
RWD Controller.
Features
• Output Signal 4 to 20 mA
• High degree of accuracy
• Rugged construction
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

4 to 20 mA Analog Sensors Specifications

Output Signal ........................................................................... 4 to 20 mA


Reference Resistance at 32°F (0°C) ........................................100 Ohms
Element Material ..........................................................................Platinum

4 to 20 mA Analog Sensors Product Ordering


Temperature Range/Mid-range Accuracy
Application Probe Length (Transmitter and Sensor Combined) Part No.
Surface Mount NA 30 to 250°F/±1.1°F (-1 to +121°C/±0.65°C) 536-780
Outdoor Air NA -58 to +122°F/±0.6°F (-50 to +50°C/±0.3°C) 536-768
4" 20 to 120°F/±0.7°F (-7 to +49°C/±0.4°C) 533-376-4
8" 533-376-8
18" 533-376-18
4" 70 to 220°F/±1.1°F (21 to 104°C/±0.6°C) 533-377-4
Duct – Single Point 8" 533-377-8
18" 533-377-18
4" 4 to 122°F/±0.7°F (-20 to +50°C/±0.4°C) 544-560-4
8" 544-560-8
B-18 18" 544-560-18
8 ft 20 to 120°F/±0.7°F (-6 to +49°C/±0.4°C) 533-380-8
Flexible Duct – Averaging 16 ft 533-380-16
Sensors

24 ft 533-380-24
18" 20 to 120°F/±0.7°F (-6 to +49°C/±0.4°C) 535-490-18
24" 535-490-24
Rigid Duct – Averaging
36" 535-490-36
48" 535-490-48
2.5" 30 to 250°F/±1.1°F (-1 to +121°C/±0.6°C) 536-767-25
B-1 4.0" 536-767-40
6.0" 536-767-60
2.5" 20 to 70°F/±0.6°F (-7 to +21°C/±0.3°C) 536-774-25
Liquid Immersion 4.0" 536-774-40
6.0" 536-774-60
2.5" 32 to 212°F/±1.0°F (0 to 100°C/±0.6°C) 544-562-25
4.0" 544-562-40
6.0" 544-562-60
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

Series 2300

Relative Humidity and Temperature


Room Units for Third-party Systems

Series 2300 Room Relative Humidity and


Relative Humidity/Temperature Sensor.

Description Full-featured Models


B-19
The Series 2300 Relative Humidity and Temperature • Digital temperature setpoint adjustment in
Room Units offer simple temperature sensing functionality. degree increments
These devices work with third party systems to deliver • Occupancy override button

Sensors
exceptional occupant comfort. All room units incorporate
• Removable, replaceable humidity element
precision humidity and temperature sensing elements
to accurately and reliably measure room temperature. • Resistive output signals
Their compact, low-profile design results in an attractive, • Selectable voltage or current output models
inconspicuous installation. Strategically placed ventilation • High degree of accuracy
slots in the housing optimize airflow through the cover for
fast measurement response and superior control. • Analog temperature display
• Organic light emitting diode
These room units provide accurate, reliable sensing of
room humidity and temperature. Various models can • Analog setpoint adjustment
be used with all equipment controllers that accept the • Occupancy override button
respective NTC thermistor or RTD inputs for primary • Dim or brighten display
control.
• Show or hide OLED display elements
Features • Local setpoint limiting
• Numerical or graphical display of temperature setpoint
• 4 to 20 mA and 0 to 10 Vdc output signals
• High degree of accuracy
Applications
These room units connect to the controller’s input points
via free wire cabling, which is landed on the controllers’
terminal block connector.
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

Series 2300 Specifications

Temperature Range Calibration Features


Setpoint and Operating..................................55F to 95°F (13C to 35°C) Temperature............................................................. Adjustable to ± 5°F
Humidity................................................................ Adjustable to ± 5% rh
Output Signals......................................................... Changing Resistance
Installation
Sensing Element Type
NTC Types..................................................100 ft. Maximum Cable Length.
QFA3312 Types................................................... 1K Ohm Platinum RTD ..................... 6C #24 AWG, Belden 1228A or Equal, NEC Class 2
QFA3330 Types ................................. 10K Ohm NTC Type II Thermistor RTD Types........................................300 to 750 ft Maximum Cable Length.
QFA3332 Types .............................................10K Ohm NTC Thermistor ..................................... 18 to 22 AWG, Twisted Pair, NEC Class 2
Accuracy Installation Adjustments.....................................................None required
10K Ohm Thermistor Cover
55° - 80.6°F (13°C - 27°C)........................................ ±0.5°F (±0.3°C) Dimensions..................... 4.5" × 2.75" × 1.18" (115 mm × 70 mm × 30 mm)
80.6° - 95°F (27°C - 35°C)........................................ ±1.0°F (±0.5°C) Color .............................................................................................. White
1K Ohm RTD Mid-range
75°F (24°C)…………………………………………... ±0.75°F (± 0.4°C) Regulatory Agency....................................................................... . UL 916
Humidity Specifications (QFA Types Only)
Humidity Range................................................................0% to 100% rh
Output Signal...............................................Select 0-5V, 0-10V, 4-20mA
Sensing Element Type..................................................Digital Sensor IC
Humidity Accuracy
10% - 90% rh......................................................................... ± 2% rh
< 10% rh; > 90% rh................................................................... .± 4% rh

Series 2300 Product Ordering


B-20 Description Part No.
Humidity Room Unit
2%, 0-10/0-5 Volt or 4-20mA Selectable Outputs, No Logo [Link]
Sensors

Humidity & Temp Room Units


2%, 0-10/0-5 Volt or 4-20mA Selectable Outputs, White, No Logo [Link]
2%, 0-10/0-5 Volt or 4-20mA Selectable Outputs, Display, Setpoint, [Link]
Override, White, No Logo, No Communication Port
RH: 0-10/0-5 Volt or 4-20mA Selectable, 2% [Link]
T: 10K Type 3 NTC, Display, Setpoint, Override, No Logo
RH: 0-10/0-5 Volt or 4-20mA selectable, 2% [Link]
B-1 T: 10K Type 2 NTC, Display, Setpoint, Override, No Logo
RH: 0-10/0-5 Volt or 4-20mA Selectable, 2% [Link]
T: 1K Platinum (385) RTD, Display, Setpoint, Override, White, No Logo
RH: 0-10/0-5 Volt or 4-20mA selectable, 2% [Link]
T: 1K Platinum (385) RTD, White, No Logo

Series 2300 Accessories Ordering Information


Description Part No.
Replacement Sensor Housing Base (For .E Models Only) 563-102-02
Replacement Sensor Housing Base (For .B Models Only) 563-102-03
Room Unit Back Plate (10-Pack) AQA2200-INTL

Accessories & Service Kits B-51


Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QFA Series 1000

Room Relative Humidity and


Relative Humidity/Temperature Sensors

QFA Series Room Relative Humidity and QFA Series Room Relative Humidity and
Relative Humidity/Temperature Sensor. Relative Humidity/Temperature Sensor.

Description Applications
B-21
The QFA Series Room Relative Humidity and Relative These units are especially suited for applications where
Humidity/Temperature Sensors monitor and transmit precise, stable humidity sensing is required.
changes in humidity and temperature to the building

Sensors
control systems.
Several models are available for humidity only
(in 5% and 2%) or for humidity and temperature sensing
(also in 5% and 2% versions). The humidity only units
are available in either 4 to 20 mA or 0 to 10 Volt signal
versions. Combination humidity and temperature units
are available in either dual current or voltage versions,
transmitting proportional signals back to the controller.

Features
Standard Features
• 4 to 20 mA and 0 to 10 Vdc output signals
• High degree of accuracy

Full-featured Models
• Liquid Crystal Display (LCD in degrees F or C)
• Digital temperature setpoint adjustment in
0.5 degree increments
• Override button
• Removable, replaceable humidity element
(2% versions only)
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QFA Series 1000 Specifications

General Temperature Effect..................................... Less than 0.1% per Degree C


Installation................................. 18 AWG Cable Length Shared in Conduit Sensing Element............................Capacitive Humidity Sensing Element
with Other Sensor Wiring 750 ft. (229 m) Max Output Signal....................................................4 to 20 mA or 0 to 10 Vdc,
Connections .................................................................... Screw Terminals 0 to 100% Linear, Proportional
Voltage Requirement................................................... 13.5 to 35 Vdc and Polarity Protection...............................................................................Yes
24 Vac (for sensors with 0-10 Vdc outputs)
CE and UL listed................................... UL 873 Standard for Temperature Humidity Element
Indicating and Regulating Equipment Temperature Element (for combination RH/T units only)
Housing Operating Temperature........................................ 32 to 122°F (0 to 50°C)
Material Type.........................................................Polycarbonate Plastic
Color .................................................................... Desert Beige or White Time Constant at 0 to 50°C and 10-80%RH ........ Approx. 20 Seconds in
Dimensions.......................................... 3-11/32" H x 2-1/2" W x 1-1/2" D Moving Air
(85 mm H x 63 mm W x 38 mm D) Accuracy................................................. at 32 to 122°F (0 to 50°C): ±1 K
Operating Range.................................................................. 0 to 100% RH at -31 to +95°F (-35 to +35°C): ±0.8 K
at -31 to +140°F (-35 to +60°C): ±1 K
Measurement Range........................................................... 0 to 100% RH
Output Signal ...................................................4 to 20 mA or 0 to 10 Vdc,
Accuracy at room temperature (73°F, 20°C)....................±5% RH for 0% 0 to 100% Linear, Proportional, (Terminal U2)
≤ RH < 30% or 70% ≤ RH < 95%
±3% RH for 30% ≤ RH < 70% Calibration Adjustments...................................................................None
Operating Temperature................................-31 to +140°F (-35 to +60°C)

QFA Series 1000 Product Ordering


B-22 Application Description Part No.
Room Relative Humidity 5% 0 to 10 Vdc, No LCD, Beige [Link]
Room Relative Humidity 5% 0 to 10 Vdc, No LCD, White [Link]
Sensors

Room Relative Humidity 5% 4 to 20 mA, No LCD, Beige [Link]


Room Relative Humidity 5% 4 to 20 mA, No LCD, White [Link]
Room Relative Humidity 5% & Temperature 0 to 10 Vdc, No LCD, Beige [Link]
Room Relative Humidity 5% & Temperature 0 to 10 Vdc, No LCD, White [Link]
Room Relative Humidity 5% & Temperature 0 to 10 Vdc, LCD, Temp Setpoint, Occupant Override, Beige [Link]
Room Relative Humidity 5% & Temperature 0 to 10 Vdc, LCD, Temp Setpoint, Occupant Override, White [Link]
B-1 Room Relative Humidity 5% & Temperature 4 to 20 mA, No LCD, Beige [Link]
Room Relative Humidity 5% & Temperature 4 to 20 mA, No LCD, White [Link]
Room Relative Humidity 5% & Temperature 4 to 20 mA, LCD, Temp Setpoint, Occupant Override, Beige [Link]
Room Relative Humidity 5% & Temperature 4 to 20 mA, LCD, Temp Setpoint, Occupant Override, White [Link]
Room Relative Humidity 2% 0 to 10 Vdc, No LCD, Beige [Link]
Room Relative Humidity 2% 0 to 10 Vdc, No LCD, White [Link]
Room Relative Humidity 2% 0 to 10 Vdc, with LCD, Beige [Link]
Room Relative Humidity 2% 0 to 10 Vdc, with LCD, White [Link]
Room Relative Humidity 2% 4 to 20 mA, No LCD, Beige [Link]
Room Relative Humidity 2% 4 to 20 mA, No LCD, White [Link]
Room Relative Humidity 2% & Temperature 0 to 10 Vdc, No LCD, Beige [Link]
Room Relative Humidity 2% & Temperature 0 to 10 Vdc, No LCD, White [Link]
Room Relative Humidity 2% & Temperature 0 to 10 Vdc, LCD, Temp Setpoint, Occupant Override, Beige [Link]
Room Relative Humidity 2% & Temperature 0 to 10 Vdc, LCD, Temp Setpoint, Occupant Override, White [Link]
Room Relative Humidity 2% & Temperature 4 to 20 mA, No LCD, Beige [Link]
Room Relative Humidity 2% & Temperature 4 to 20 mA, No LCD, White [Link]
Room Relative Humidity 2% & Temperature 4 to 20 mA, LCD, Temp Setpoint, Occupant Override, Beige [Link]
Room Relative Humidity 2% & Temperature 4 to 20 mA, LCD, Temp Setpoint, Occupant Override, White [Link]
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QFA Series

Room/Outdoor Air Relative Humidity and


Relative Humidity/Temperature Sensors

AQY2010 QFA3100 Series AQF3100


Remote Sensing Cable Outdoor Air Relative Humidity and Sunshield for Sensor.
Shown with QFA3100. Relative Humidity/Temperature Sensor. Sold Separately.

Description Applications
B-23
The QFA Series Outdoor Air Relative Humidity and The QFA Series Outdoor Air Relative Humidity and
Relative Humidity/Temperature Sensors monitor and Relative Humidity/Temperature Sensors are especially
transmit changes in humidity and temperature to the suited for applications where precise, stable humidity

Sensors
building control systems. Standard models available sensing is required.
are 2% and 2% certified, for both humidity only and
combination humidity with temperature sensing.
Sensors are offered with either 4 to 20 mA or
0 to 10 Volt output signals.

Features
• 4 to 20 mA or 0 to 10 Vdc output signals
• High degree of accuracy
• Removable, replaceable sensing tip sold seperately
on B-39
• Display model is available on QFA series version
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QFAx1 Specifications

General Humidity Element


Installation................................................. 18 AWG cable length shared in Operating Range.................................................................. 0 to 100% RH
conduit with other sensor wiring 750 ft. (229 m) max Measurement Range............................................................. 0 to 95% RH
Connections .................................................................... Screw Terminals Accuracy at Room Temperature (73°F, 20°C)...........±2% RH, 0-95% RH
Dimensions Operating Temperature................................-31 to +140°F (-35 to +60°C)
Outdoor Air Probe................. 6" O.D. x 3.3" L (15 mm O.D. x 84 mm L) Temperature Effect......................................Less than 0.1% per degree C
Outdoor Air Housing........................................... 3.1" L x 2.3" W x 1.5" D
(80 mm L x 60 mm W x 40 mm D) Sensing Element............................. Capacitive humidity sensing element
Shield (mounted)............................................. 3.43" H x 3.5" W x 4.1" D Output Signal
(87 mm L x 89 mm W x 104 mm D) RH only units... 4 to 20 mA or 0 to 10 Vdc, 0 -100% Linear, Proportional
RH & T units.... 4 to 20 mA or 0 to 10 Vdc, 0 -100% Linear, Proportional
Voltage Requirement................................................... 13.5 to 35 Vdc and
24 Vac ( for sensors with 0-10 Vdc outputs) Polarity Protection...............................................................................Yes
Material Type............................................................ Polycarbonate plastic
CE and UL listed....................................UL 873 standard for Temperature
Indicating and Regulating Equipment

Temperature Element (for Combination RH/T Units Only)


Application Temperature
Operating Temperature Jumper Selectable 32 to 122°F (0 to 50°C) or -31 to +95°F (-35 to +35°C)
32 to 122°F (0 to 50°C) or -31 to +140°F (-35 to +60°C)
Time Constant at 0 to 50°C and 10 to 80% RH Approx. 20 seconds in moving air
B-24 Accuracy at 59 to 95°F (15 to 35°C): ±0.8 K
at 31 to 122°F (-35 to +50°C): ±1 K
at 31 to 140°F (-35 to +60°C): ±1 K
Sensors

Output Signal 4 to 20 mA or 0 to 10 Vdc, 0 -100% linear, proportional, (terminal U2)


Calibration Adjustments None

QFAx1 Series Product Ordering


Application RH Description Part No.
B-1 Room/Outdoor Air Humidity 2% 0 to 10 Vdc QFA3100
Room/Outdoor Air Humidity 2% 4 to 20 mA QFA3101
Room/Outdoor Air Humidity & Temperature 2% 0 to 10 Vdc / Temp 0 to 10 Vdc QFA3160
Room Air Humidity & Temperature 2% 0 to 10 Vdc / Temp 0 to 10 Vdc with Display QFA3160D
Room/Outdoor Air Humidity & Temperature 2% 4 to 20 mA / Temp 4 to 20 mA QFA3171
Room Air Humidity & Temperature 2% 4 to 20 mA / Temp 4 to 20 mA with Display QFA3171D
Room/Outdoor Air Humidity & Temperature 2% 4 to 20 mA / Temp 4 to 20 mA (Certified) QFA4171
Room Air Humidity & Temperature 2% 4 to 20 mA / Temp 4 to 20 mA (Certified) with Display QFA4171D
Room Outdoor Air Humidity & Temperature 2% 0 to 10 Vdc, Temp 0 to 10 Vdc (Certified) QFA4160
Room Air Humidity & Temperature 2% 0 to 10 Vdc, Temp 0 to 10 Vdc (Certified) with Display QFA4160D

QFAx1 Series Accessories


Description Part No.
Outdoor Air Sunshield AQF3100
Remote Sensing Cable, 10 Foot AQY2010
Remote Sensing Cable, 30 Foot AQY2030

Accessories & Service Kits B-51


Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QFM Series

Duct Relative Humidity/Temperature Sensors

QFM Series Duct Relative QFM Series Duct Relative Humidity and
Humidity Sensor. Relative Humidity/Temperature Sensor.

Description Applications
B-25
The QFM Series Duct Relative Humidity and Relative The QFM Series Duct Relative Humidity and Relative
Humidity/Temperature Sensors monitor and transmit Humidity/Temperature Sensors are especially suited for
changes in humidity and temperature to the building applications where precise, stable humidity sensing

Sensors
control systems. Several models are available for humidity is required.
only (in 5%, 2% and 2% certified) or for humidity and
temperature sensing (also in 5%, 2% and 2% certified
versions). The humidity only units are available in either
4 to 20 mA or 0 to 10 Volt signal versions. Combination
humidity and temperature units are also available in either
dual current or voltage versions, transmitting proportional
signals back to the controller. Nickel 1000 Ohm (Siemens
type) or Platinum 1000 Ohm RTD (385 ALPHA type)
temperature outputs on combination versions are
also offered.

Features
• 4 to 20 mA or 0 to 10 Vdc output signals
• High degree of accuracy
• Removable, replaceable sensing tip
(2% and 2% certified models)
• Versions with LCD display also available
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QFM Series Specifications

General Humidity Element


Installation.................................... 18 AWG cable length shared in conduit Operating Range.................................................................. 0 to 100% RH
with other sensor wiring 750 ft. (229 m) max Measurement Range............................................................. 0 to 95% RH
Connections .................................................................... Screw Terminals Accuracy at Room Temperature ≈ 73°F (20°C):
Dimensions All types:............................. ±5% RH, 0-95% RH (±3% RH, 30-70% RH)
Probe.................................. 0.6" O.D. x 7.2"L (15 mm O.D. x 183 mm L) ±2% RH, 0-95% RH
Housing...3.1" L x 2.3" W x 1.5" O.D. (80 mm L x 60 mm W x 40 mm D)
Operating Temperature Jumper Selectable........ 32 to 122°F (0 to 50°C)
Voltage Requirement................................................... 13.5 to 35 Vdc and or -31 to 95°F (-35 to 35°C)
24 Vac (for sensors with 0-10 Vdc outputs) or -31 to 140°F (-35 to 60°C)
Input Impedance (4 to 20 mA versions only)............ Less than 500 Ohms Temperature Effect......................................Less than 0.1% per degree C
Housing Material Type ..............Polycarbonate plastic, UL 94-5VB rated, Sensing Element............................. Capacitive humidity sensing element
suitable for plenum installations
Output Signal
Housing Protection Class.................. IP 65 (QFM3xxx, QFM4xxx types), RH only units......................4 to 20 mA and 0 to 10 Vdc, 0-100% Linear,
IP54 (QFM2xxx types), NEMA 1 (all types) Proportional
Filter Material and Specification........................... Teflon, 10 micron filter RH/T units...............................0 to 10 Vdc, 0-100% Linear, Proportional
Agency Certification........ UL listed to UL 873 for Temperature Indicating Polarity Protection...............................................................................Yes
and Regulating Equipment
CE Conformance.............. EC Directive on electromagnetic compatibility:
89/336/EEC

Temperature Element Specifications (for Combination RH/T Units Only)


B-26 QFM2110 (Platinum) QFM2160 QFM31xx
QFM2120 (Nickel) QFM2171 QFM41xx
Operating Temperature -31 to +140°F (-35 to +60°C) -31 to +122°F (-35 to +50°C) -31 to +158°F (-35 to +70°C)
Time Constant Approximately 20 seconds in moving air
Sensors

+/-0.6K — ­— 59 to 95° F (15 to 35°C)


Accuracy +/0.8K 59 to 95ºF (15 to 35ºC) 59 to 95ºF (15 to 35ºC) 31 to 158ºF (-35 to +70ºC)
+/-1.0K 31 to 140°F (-35 to +60°C) -31 to +122°F (-35 to +50°C) ­—
Platinum 1K Ohm RTD (385) 0 to 10 Vdc (QFMx160)
Output Signal
Nickel 1K Ohm RTD (Siemens) 4 to 20 mA (QFMx171)
Calibration None
B-1

QFM Series Product Ordering


Application Description Part No.
Duct Humidity 5% 0 to 10 Vdc QFM2100
Duct Humidity 5% 4 to 20 mA QFM2101
Duct Humidity 5% & Temperature 0 to 10 Vdc / Temp 1K Ohm Platinum RTD (385 Alpha) QFM2110
Duct Humidity 5% & Temperature 0 to 10 Vdc / Temp 1K Ohm Nickel RTD (L&S Type) QFM2120
Duct Humidity 5% & Temperature 0 to 10 Vdc / Temp 0 to 10 Vdc QFM2160
Duct Humidity 5% & Temperature 4 to 20 mA / Temp 4 to 20 mA QFM2171
Duct Humidity 2% 0 to 10 Vdc QFM3100
Duct Humidity 2% 4 to 20 mA QFM3101
Duct Humidity 2% & Temperature 0 to 10 Vdc, Temp 0 to 10 Vdc QFM3160
Duct Humidity 2% & Temperature 0 to 10 Vdc, Temp 0 to 10 Vdc, w/Display QFM3160D
Duct Humidity 2% & Temperature 4 to 20 mA / Temp 4 to 20 mA QFM3171
Duct Humidity 2% & Temperature 4 to 20 mA / Temp 4 to 20 mA, w/Display QFM3171D
Duct Humidity 4 to 20 mA (Certified) QFM4101
Duct Humidity & Temperature 0 to 10 Vdc, Temp 0 to 10 Vdc (Certified) QFM4160
Duct Humidity & Temperature 4 to 20 mA / Temp 4 to 20 mA (Certified) QFM4171
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

590 Series

Very Low Differential


Pressure Transducers

Very Low Differential Pressure Transducers.

Description Applications
B-27
The Very Low Differential Pressure Transducers sense The Very Low Differential Pressure Transducers are used
differential or gauge (static) pressures and convert for the following applications:
pressure difference to a proportional electrical output. • Heating, Ventilation and Air Conditioning (HVAC)

Sensors
The 590 Series is offered with a 0 to 10 Vdc output.
• Energy Management Systems
Used in Building Energy Management Systems, these • Variable Air Volume (VAV) and Fan Control
transducers are capable of measuring pressures with the
• Environmental pollution control
accuracy necessary for proper building pressurization and
air-flow control. • Static duct and clean room pressures

The 590 Series Transducers are available in five different


air pressure ranges. Static accuracy is ±1% full scale in
normal ambient temperature environments. The units are
temperature compensated to less than ±0.033% FS/°F of
thermal error over the temperature range of 0°F to +150°F.

Features
• 10 psi proof pressure on all ranges
• 24 Vac
• 0 to 10 Vdc analog output is compatible with all energy
management systems
• Fully protected against reverse wiring
• Internal regulation permits use with unregulated
DC power supplies
• 1% accuracy, or better, improves variable air volume
system performance
• Meet CE conformance standards
• No field calibration or adjustment necessary
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

590 Series Specifications

Temperature Electrical Data (Voltage)


Operating*..................................................... 0 to +150°F (-18 to +65°C) Circuit ...................................................................3-wire (Com, Out, Exc)
Storage.......................................................-40 to +185°F (-40 to +85°C)
Excitation/Output**............................................. 12 to 30 Vac/0 to 10 Vdc
* Operating Temperature limits of the electronics only.
Pressure media temperatures may be considerably higher or lower. **Zero output factory-set to within ±50 mV (±25 mV for optional
accuracies).
Physical Description
Bi-directional Output at Zero Pressure........................2.5 Vdc (±50 mV)
Case Fire Retardant Glass Filled Polyester
Output Impedance***.................................................................100 Ohms
Electrical Connection..............................................Screw Terminal Strip
***Calibrated into a 50K ohm load, operable into a 5000-ohm load
Pressure Fitting.......................................................................1⁄4" Fitting or greater.
Weight.......................................................................................3 ounces Pressure Media....................Typically air or similar non-conducting gases

590 Series Product Ordering


Description Accuracy Part No.
Differential Pressure Sensor, 5" WC, 10 Vdc Signal 1% 590-501
Differential Pressure Sensor, 2" WC, 24 Vac, 10 Vdc Signal 1% 590-502
Differential Pressure Sensor, 1" WC, 24 Vac, 10 Vdc Signal 1% 590-503
Differential Pressure Sensor, ±0.25" WC, 24 Vac, 10 Vdc Signal 1% 590-505
Differential Pressure Sensor In Conduit Box, 5" WC, 24 Vac, 10 Vdc Signal 1% 590-506

B-28 Differential Pressure Sensor In Conduit Box, 2" WC, 24 Vac, 10 Vdc Signal 1% 590-507
Differential Pressure Sensor In Conduit Box, 1" WC, 24 Vac, 10 Vdc Signal 1% 590-508
Differential Pressure Sensor In Conduit Box, ±0.25" WC, 24 Vac, 10 Vdc Signal 1% 590-510
Differential Pressure Transmitter, 1.0", 0.4%, 4 to 20 mA, Conduit Cover, 24 Vac 0.4% 590-780
Sensors

Differential Pressure Transmitter, .65", 0.4%, 4 to 20 mA, Conduit Cover, 24 Vac 0.4% 590-781
Differential Pressure Transmitter, 0.5", 0.4%, 4 to 20 mA, Conduit Cover, 24 Vac 0.4% 590-782

B-1
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

7MF Series

Pressure Sensors for Liquid and Gas

Pressure Sensor.

Description Applications
B-29
The 7MF Series Pressure Sensors are suitable for the The 7MF Series Pressure Sensors are used for the
measurement of static and dynamic positive pressure in following applications:
HVAC facilities, particularly in hydraulic and pneumatic • Heating, Ventilation and Air Conditioning (HVAC)

Sensors
systems using liquid or gaseous media (steam applications).
• Energy Management Systems
The 7MF Series Pressure Sensors are available in several • Chiller, Boiler and Steam Applications
different air pressure ranges, from 1 to 40 atmospheres of
pressure (1 to 580 psi).

Features
• Piezo-resistive measuring system
• 0 to 10 Vdc and 4 to 20 mA output signals
• Measurement unaffected by changes in temperature
• High temperature stability
• No mechanical aging or creepage
• Excellent EMC characteristics
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

7MF Specifications

Power Supply Media............................................................Neutral and slightly corrosive


Supply Voltage................................................................... DC 16...33 V liquids and gases
Max. Voltage Tolerance...............................................±15 % at AC 24 V Admissible temperature of medium......... -40 to +239°F (-40 to +125°C)
Current Consumption....................................................................<4 mA
Maintenance................................................................... Maintenance-free
Output Signal
4 to 20 mA ................ two-wire connection; power supply DC 10 to 36V Mounting Position........................................................................Optional
0 to 10 V .................three-wire connection; power supply DC 15 to 36V Connecting Cable............ PVC, length 5 ft., 3 x 0.25 mm2 stranded wires
Application Range...................................0 to 40 bar, refer to table below. Screwed Fitting........................................................External thread G1⁄2"
Accuracy......................................................................... (FS = Full Scale) Operation to Climatic Conditions
Total of linearity, hysteresis Temperature........................................................................-40 to +85°C
and reproducibility................................................................ <±0.3 % FS Humidity...................................................................................<95% RH
Zero point offset voltage.............................................................. <30 Mv Storage/transport Climatic Conditions
Temperature........................................................................-40 to +85°C
Temperature Drift Humidity...................................................................................<95% RH
TC zero point.................................................<±0.015 % FS/K (typically)
CE conformity to EMC Directive...........................................89/336/EEC
TC sensitivity.................................................<±0.015 % FS/K (typically)
N474 Conformity to
Response Time................................................................................ <2 ms Australian EMC Framework..................Radio Communication Act 1992
Nominal Pressure................................. Relative pressure as in “Ordering Radio Interference Emission Standard............................. AS/NZS 3548
Information” (measurement of difference Base......................................................................Stainless Steel (1.4305)
from ambient pressure)
Measuring Element..................................................Ceramics diaphragm
Max. Admissible Pressure and
Rupture Pressure................................. 3 x scale end value of measuring Cover....................................................................Stainless Steel (1.4305)
range (FS) <4 bar Sealant........................................................................... FPM (Viton) spec.
2.5 x scale end value of Shipping Weight............................................................. 0.53 lb. (0.24 kg)
measuring range (FS) >4 bar
B-30

7MF Series Product Ordering


Sensors

Pressure
Range (psi) Output Signal Part No.
0 to 15 psi 4 to 20 mA 7MF15644BB003EA1
0 to 30 psi 4 to 20 mA 7MF15644BE003EA1
0 to 60 psi 4 to 20 mA 7MF15644BF003EA1
0 to 100 psi 4 to 20 mA 7MF15644BG003EA1
B-1 0 to 150 psi 4 to 20 mA 7MF15644CA003EA1
0 to 200 psi 4 to 20 mA 7MF15644CB003EA1
0 to 300 psi 4 to 20 mA 7MF15644CD003EA1
0 to 15 psi 0 to 10 V 7MF15644BB103EA1
0 to 30 psi 0 to 10 V 7MF15644BE103EA1
0 to 60 psi 0 to 10 V 7MF15644BF103EA1
0 to 100 psi 0 to 10 V 7MF15644BG103EA1
0 to 150 psi 0 to 10 V 7MF15644CA103EA1
0 to 200 psi 0 to 10 V 7MF15644CB103EA1
0 to 300 psi 0 to 10 V 7MF15644CD103EA1

Accessories & Service Kits B-51


Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

536

Pitot Tube Sensor Kits

536 Pitot Tube Sensor Kit.

Description Applications
B-31
The Pitot Tube Sensor Kit is used with either static or This kit is used in situations where a terminal box
differential air pressure sensing devices, to measure manufacturer-supplied sensor (flow pick-up) is not
average static or differential pressure across a duct. available, or where the existing flow pick-up has

Sensors
been damaged.
Features
• Thin steel construction
• Mounting flange is easily bent to conform to round or
oval ducts
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

Pitot Tube Sensor Kits Specifications

Material
Probe...............................................................................6061 aluminum
Gasket..............................................1/4-in (6 mm) closed-cell neoprene
Tubing............................................................................FR polyethylene
Mounting Flange.......................................26 GA galvanized sheet steel
Mounting
Screws.............................................................................#8 self-tapping
. 1/4-in (6 mm) hex washer head
Flange hub............................................................#10 pan head, slotted
Dimensions............................................................................ 1.50" x 3.75"
(38 mm x 95 mm)

Pitot Tube Sensor Kits Product Ordering


Duct Size Maximum Probe Length Part No.
6" (152 mm) 5.75" (146 mm) 536-376
8" (203 mm) 7.75" (197 mm) 536-378
10" (254 mm) 9.75" (248 mm) 536-380
12" (305 mm) 11.75" (298 mm) 536-382
14" (356 mm) 13.75" (349 mm) 536-384
B-32
Sensors

B-1
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QPA Series

Room CO2/VOC/Temperature/RH

QPA2060D Q Series
Room Carbon Dioxide & Temperature Sensor.

Description Applications
B-33
The QPA Series Room Carbon Dioxide Sensors monitor These units are especially suited for applications where
and transmit changes in CO2 to the building control precise, stable CO2 sensing is required.
systems. No calibration of the CO2 sensor is necessary
— these microprocessor-based units consist of a non-

Sensors
dispersive infrared CO2 sensor that experiences less
than 1% drift per year for the first two years of operation
and negligible drift thereafter. All variants for CO2 and
combination versions with Temperature or VOC deliver
0 to 10 Volt proportional signals to the controller.

Features
• LCD display option
• Various models:
CO2
CO2/VOC
CO2/Temp
CO2/Temp/RH
• Built-in test function for troubleshooting
• Jumper selectable °C/°F units for temp models
w/display
• No Logo versions available
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QPA Series Specifications

General Output Signal.............................0 to 10 Vdc, 0-100% Linear, Proportional


Installation.................................... 18 AWG cable length shared in conduit Polarity Protection...............................................................................Yes
with other sensor wiring 750 ft. (229 m) max Permissible Air Velocity in the Room.......................................<26.2 ft./s
Connections .....................................................................Screw terminals
Dimensions.................................................... 3.94" H x 3.54" W x 1.65" D Temperature Element
(100 mm x 90 mm x 42 mm) (for Combination CO2/T unit only)
Voltage Requirement.......................................................... 13.5 to 35 Vdc Operating Temperature .......................................23 to 113°F (-5 to 45°C)
Housing Protection Class............................................NEMA 1 (all types) Time Constant ............................................................................<1 minute
Accuracy........................................................................................... ±0.8K
CO2 Element Output Signal .............................................................................0-10 volts
Operating Range................................................................... 0 - 2000 ppm Calibration ......................................................................... None Required
Accuracy at Room Temperature ≈ 73°F (20°C)..........................+2% mV
Operating Temperature.................................. -23 to +113°F (-5 to +45°C) Humidity Element
Temperature Effect......................................Less than 0.1% per degree C Measuring Range................................................................ 0 to 100% RH
Sensing Element.............................................NDIR CO2 sensing module Accuracy....................................................................................... ±5% RH

QPA Series Product Ordering


Application Description Part No.
CO2 0 to 5 V or 0 to 10 V QPA2000
B-34
CO2 0 to 5 V or 0 to 10 V, No Logo QPA2000N
CO2 and VOC 0 to 5 V or 0 to 10 V QPA2002
CO2 and VOC 0 to 5 V or 0 to 10 V, with Display QPA2002D
Sensors

CO2 and VOC 0 to 5 V or 0 to 10 V, No Logo QPA2002N


CO2 and Temp (Active) 0 to 5 V or 0 to 10 V QPA2060
CO2 and Temp (Active) 0 to 5 V or 0 to 10 V, with Display QPA2060D
CO2 and Temp (Active) 0 to 5 V or 0 to 10 V, No Logo QPA2060N
CO2, Temp and RH (Active) 0 to 5 V or 0 to 10 V QPA2062
CO2, Temp and RH (Active) 0 to 5 V or 0 to 10 V, with Display QPA2062D
B-1
VOC 0 to 5 V or 0 to 10 V QPA1000
VOC 0 to 5 V or 0 to 10 V, No Logo QPA1000N
CO2 and Temp (Passive)* 0 to 5 V or 0 to 10 V T (Selectable R) QPA2080
CO2 and Temp (Passive)* 0 to 5 V or 0 to 10 V, T (Selectable R) with Display QPA2080D

*Resistance included: P+100, P+1000, LG-Ni 1000, NTC 10K

Accessories & Service Kits B-51


Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QPM Series

Duct CO2/VOC/Temperature/RH

QPM 2100 CO2 only Sensor.

Description Applications
B-35
The QPM Series Duct CO2 Sensors monitor and transmit These units are especially suited for applications where
changes in CO2 to the building control systems. Several precise, stable CO2 sensing is required.
models are available for CO2 only, CO2/Temp, CO2/Temp/
RH and CO2/VOC. All variants for CO2 and combination

Sensors
versions with Temperature or VOC deliver 0 to 10 Volt
proportional signals to the controller.
No calibration of the CO2 sensor is necessary — these
microprocessor-based units consist of an NDIR sensor
that experiences less than 1% drift per year for the first
two years of operation and negligible drift thereafter.

Features
• LCD display option
• Various models:
CO2
CO2/VOC
CO2/Temp
CO2/Temp/RH
• Jumper selectable °C/°F units for temp models
w/display
• No Logo versions available
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QPM Series Specifications

General Temperature Effect......................................Less than 0.1% per degree C


Installation................................................. 18 AWG cable length shared in Sensing Element.............................................NDIR CO2 sensing module
conduit with other sensor wiring 750 ft. (229 m) max. Output Signal.............................. 0 to 10 Vdc, 0-100% linear, proportional
Connections .....................................................................Screw terminals Polarity Protection...............................................................................Yes
Voltage Requirement......................................................... 13.5 to 35 Vdc Permissible Air Velocity in the Duct.........................................<26.2 ft./s
Q Series sensors with 0-10 Vdc outputs can also operate on 24 Vac
Input Impedance (4 to 20 mA versions only)......... Less than 500 Ohms Temperature Element
(for Combination CO2/T unit only)
CO2 Element Operating Temperature ............................... -31 to +113°F (-35 to +45°C)
Operating Range................................................................... 0 - 2000 ppm Time Constant .................................................................................<1 min
Accuracy at Room Temperature ≈ 73°F (20°C).............+2% mean value Accuracy.............................................................................................. ±1K
Operating Temperature................................ -31 to +113°F (-35 to +45°C) Output Signal............................................................................0 to 10 Volt
Calibration ......................................................................... None Required

QPM Series Product Ordering


Application Description Part No.
Duct Sensor, CO2 0 to 5 or 0 to 10 Vdc QPM2100
Duct Sensor, CO2 0 to 5 or 0 to 10 Vdc, No Logo QPM2100N
Duct Sensor, CO2 and VOC 0 to 5 or 0 to 10 Vdc QPM2102
B-36 Duct Sensor, CO2 and VOC  0 to 5 or 0 to 10 Vdc with Display QPM2102D
Duct Sensor, CO2 and Temp. (Active) 0 to 5 or 0 to 10 Vdc QPM2160
Duct Sensor, CO2 and Temp. (Passive*) 0 to 5 or 0 to 10 Vdc (Selectable Resistance) QPM2180
Sensors

Duct Sensor, CO2 and Temp. (Active) 0 to 5 or 0 to 10 Vdc with Display QPM2160D


Duct Sensor, CO2, RH and Temp. (Active) 0 to 5 or 0 to 10 Vdc QPM2162
Duct Sensor, CO2, RH and Temp. (Active) 0 to 5 or 0 to 10 Vdc with Display QPM2162D
Duct Sensor, VOC 0 to 5 or 0 to 10 Vdc QPM1100

*Resistance included: Pt100, Pt1000, LG-Ni 1000, NTC 10k

B-51
B-1 Accessories & Service Kits
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QVM62.1

Air Velocity Sensor

QVM62.1 Air Velocity Sensor.

Description Applications
B-37
This sensor is used to control the air velocity to a This sensor is primarily used to set the basic volumetric
constant value, balance out pressure fluctuations (supply flow rate for modulating fan control.
or exhaust air control), or to monitor the flow in air ducts.
It is designed with a thin film sensing element and its

Sensors
unique, sleek housing guarantees product recognition.
This unit is compatible with all Siemens systems and
controllers.

Features
• Mounting flange allows the installer to vary the probe
insertion length into the duct space for best control
• Mounting flange dampening gasket minimizes vibration
• Graduated probe ensures maximum flow accuracy
• Flow directional arrow provides for the most
accurate reading
• Connection cable provides mounting flexibility
• Three jumper selectable flow measuring ranges
accommodate any application or environment
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QVM62.1 Sensor Specifications

Power Supply Connections


Operating Voltage........................................................... 24 Vac +/- 20% Mechanical................................................................. Screw Connection
Frequency................................................................................. 50/60 Hz Electric...................................... Screw Terminal, Maximum 2 x 18 AWG
Power Consumption..................................... < 5 VA (maximum 200 mA) Degree of Protection
Output Impedance..................................................................... <20 ohm Degree of Protection Provided by Enclosures as per EN 60 529
Measuring Data Transducer...................................................................................... IP 42
Measuring Ranges, Adjustable............................0 to 16 ft/s (0 to 5 m/s) Sensor head.................................................................................... IP 20
0 to 33 ft/s (0 to 10 m/s) Degree of protection as per EN 60 730.................................................III
(factory setting) Climatic Conditions
0 to 49 ft/s (0 to 15 m/s) Temperature...............................................23°F to 113°F (-5°C to 45°C)
Measuring Accuracy at 68°F (20°C), 45% rh, .......................... ± 0.7 ft/s Humidity (non-condensing)........................................................ <95% rh
1013 hPa .......................................... (0.2 m/s + 3% of measured value) Mechanical Conditions............................................................Class 3M2
Permissible Air Velocity....................................................66 ft/s (20 m/s) Chemical Conditions...............................................................Class 3C2
Direction Dependence................... < 0.3% of measured value at < + 10° Storage (Transducer and Immersion Stem)
Time Constant t90 at 10 m/s..................................................... 4 seconds Temperature...............................................23°F to 113°F (-5°C to 45°C)
Signal Output U1 Humidity (Non-condensing)........................................................ <95% rh
Voltage.................................................................................. 0 to 10 Vdc Mechanical Conditions............................................................Class 1M2
Current........................................................................................ ± 1 mA Weight with Packaging....................................................12 oz (0.352 kg)
Line Length
Permissible Length to Controller at:
20 AWG Copper Cable........................................................ 164 ft (50 m)
18 AWG Copper Cable...................................................... 492 ft (150 m)
16 AWG Copper Cable...................................................... 984 ft (300 m)
Line Length to the Sensor Head..............................3 ft (1 m) (prewired)

B-38

QVM62.1 Sensor Product Ordering


Sensors

Application Description Part No.


Air Velocity Sensor 0 to 3000 FPM QVM62.1

Accessories & Service Kits B-51


B-1
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QLS60

Solar Impact Sensor

QLS60 Solar Impact Sensor.

Description Applications
B-39
The outdoor wall-mounted Solar Impact Sensor (QLS60) This sensor can be used in connection with all types of
is used as a demand sensor for heating, ventilation and systems and devices capable of acquiring and handling
air-conditioning in facilities where compensation of solar the sensor's 4 to 20 mA or 0 to 10 Vdc output signal.

Sensors
radiation is required or desired. Solar compensation is
necessary where buildings or building sections with large
window areas are subjected to strong solar radiation,
especially in installations where thermostatic radiator
valves cannot be used.
To determine the impact of solar radiation, the sensor uses
a solar cell that acquires the level of radiation. That cell
generates an electrical current depending on the extent
of radiation, which is then evaluated by the sensor. As a
result, the sensor delivers an output signal of 4 to 20 mA
or 0 to 10 Vdc, which is proportional to the solar radiation
range.

Features
• Configurable 0-10 Vdc, 4-20 ma output signal
• 24 Vac or 18-30 Vdc power source
• Output signal linear over entire measuring range
• Measuring range of 0-93 w/ft2 (0-1000 w/m2)
• Rain- and moisture-resistant NEMA 4 enclosure
• Small compact housing (2" x 3.62" x 1.8")
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QLS60 Specifications

Rated Voltage Range............................................... 24 Vac (± 20% SELV) Electrical Connections


..................................................................... or 24 Vdc (18 to 30V) Screw Terminals for......................................2 × 16 AWG or 1 × 12 AWG
Power Supply (G+, M) Degree of Protection of Housing.............................. IP 65 to IEC 60 529
Rated Frequency at 24 Vac........................................................ 50/60Hz Insulation Class.................................................................III to EN 60 730
Rated Power Consumption.........................................Max. 2.5 VA (1 W)
Environmental Conditions
Measuring Range............................................................. 0 to 1000 W/m2 Operation to....................................................................... IEC 60 721-3
Time Constant t63..................................................................</- 2 seconds Climatic Conditions................................................................. Class 3K5
Measured Value Outputs (U, I) Temperature........................................... -13°F to 131°F (-25°C to 55°C)
Voltage Signal Output (U)............................ 0 to 10 Vdc 0 = 1000 W/m2 Humidity (Non-condensing)................................................... 5 to 95% rh
Current Signal Output (I)...............................4 to 30 mA 0 to 1000 W/m2 Mechanical Conditions ...........................................................Class 3M2
Transportation to............................................................. IEC 60 721-3-2
Permissible Cable Lengths With Copper Cable Climatic Conditions................................................................. Class 2K3
18 AWG........................................................................... 164 feet (50 m) Temperature.............................................. -13F to 158°F (-25C to 70°C)
16 AWG......................................................................... 492 feet (150 m) Humidity..................................................................................... <95% rh
12 AWG......................................................................... 984 feet (300 m) Mechanical Conditions............................................................Class 2M2
Agency Standards.......................................................UL Listed to UL873
....................... cUL Listed to Canadian Standard C22.2 No. 24-93
................................CE conformity to EMC directive 2004/108/EC

B-40 QLS60 Product Ordering


Description Output Signal Part No.
Solar Impact Sensor 4 to 20 mA or 0 to 10 Vdc QLS60
Sensors

Accessories & Service Kits B-51

B-1
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QVE Series

Liquid Flow Switches

QVE1900U Liquid Flow Switch. QVE1901U Liquid Flow Switch.

Description Applications
B-41
The QVE1900U Flow Switch is for liquids in piping Flow switches are used to monitor the flow of fluids in
1-1/4-inch to 8-inch (20 mm to 200 mm) diameter. The hydraulic systems, especially in refrigeration and heat
QVE1901U Flow Switch is for liquids in piping 3/4-inch to pumps, and are for use with condensers, boilers, and heat
8-inch (20 mm to 200 mm) diameter.

Sensors
exchangers.
These two units have the same general principle of
operation, although their switching mechanisms are
different. Both detect the flow of the medium to be
monitored by means of a paddle. If the flow velocity in
the piping falls below the adjusted switch-off value, the
paddle in the QVE1900U model actuates a micro-switch
with a dry contact (S.P.D.T.), which closes the contact.
When the flow velocity reaches the switch-on value again,
the opposite contact closes. In the QVE1901U model, the
switching is achieved through a system of two opposite
magnets and a reed contact. The switching point is
adjustable on both devices.

Features
• Compatible with all currently offered zone (TEC, ATEC)
or primary controllers (PXC) that are offered as part of
the APOGEE building automation system
• Detachable steel paddles provide correct flow
measurement based on pipe diameter
• Contact load/switching capacity: Maximum 24 Vac, 1 A,
26 VA Maximum 24 Vdc, 1 A, 20 W
• Nominal pressure PN25
• Manual setting of contact type (NO/NC)
• Housing IP 65 per EN 60 529
• Maintenance-free
• Suitable for all liquids (except ammonia)
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QVE Series Specifications

Piping Diameter Operation and Storage


QVE1900U.....................................................DN 1.25 (32) to 8.00 (200) QVE1900U................................................ –4F to 158°F (–20C to 85°C)
QVE1901U........................................................DN 20 to 200 (3/4” to 8”) QVE1901U................................................ –4F to 176°F (–20C to 80°C)
Type of Switch Ambient Humidity (QVE1901U).................................................. <95% rh
QVE1900U..........................Micro Switch with Single-Pole Changeover, Agency Listings............................................. UL Listed for UL 873 XAPX
................................................................................. Potential Free ......................................................... cUL C22.2 No. 24-93 XAPX7
QVE1901U.........................................................................Reed Contact
Housing Base
Contact Rating QVE1900U............................................. Bayblend T85/Color RAL 7015
QVE1900U..................................................................... 24 Vac, 15 (8) A QVE1901U................................................................... Polyamide, black
QVE1901U......................................................... 24 Vac, 1 A/24 Vdc, 1 A
Materials
Adjustment of Switching Point..............Manual, Supplied with Minimum QVE1900U.......................................................Screw-in body R1" Brass
......................................................................Switch On/Off Values QVE1901U............................................... Screw-in body NPT ½” Brass
Permissible Medium Temperature............–4F to 248°F (–20C to 120°C) Paddle
..........................................................(Medium must be Antifreeze) QVE1900U Only .................................................High-grade steel (V2A)
Permissible Operating Pressure (QVE1900U)...............................PN 10 Flow Switch, Overall (QVE1900U) ........................................Silicone-free
Nominal Pressure (QVE1901U).......................................................PN 25
Degree of Protection
Housing...................................................................IP 65 per EN 60 529
Safety Class
QVE1900U.................................................................... I per EN 60 730
QVE1901U.................................................................. III per EN 60 730

B-42
Flow Switch Product Ordering
Description Part No.
Sensors

SPDT, 15A, 1-1/4" to 8" pipe QVE1900U


SPST, 1A, 3/4" to 8" pipe QVE1901U

Accessories & Service Kits B-51


B-1
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QXA2000

Condensation Sensor

QXA2000 Condensation Sensor.

Description Applications
B-43
The QXA2000 Condensation Sensor is used to avoid For monitoring condensation in buildings that are running
damage due to condensation on chilled ceilings and in chilled beam or chilled ceilings or in heating, ventilation, or
HVAC installations. air conditioning installations.

Sensors
It operates on AC/DC 24V and has a NO/NC changeover The condensation sensor is used
dry contact relay output capable of switching AC/DC loads
• to prevent condensation on chilled ceilings
from 1 to 48V, 0.5 amp.
• to prevent condensation at critical spots of HVAC
Features installations or buildings (in air ducts, near fans,
and so on)
• Comes complete with a strap-on band for pipe diameters
from 0.39 to 3.94 inches (10 to 100 mm), and thermal • as a condensation switch
conductive paste
In general, the condensation sensor is for use on all kinds
of surfaces where condensation must be avoided.
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QXA2000 Condensation Sensor Specifications

Power Supply G (G+), G0 (G-) Environmental Conditions


Operating Voltage.................................................... AC/DC 24V + 20% Operation to ................................................................... IEC 60721-3-3
Frequency................................................................................ 50/60 Hz Climatic Conditions ........................................................... Class 3K5
Power consumption........................................................ Maximum 1 VA Temperature (Housing & Electronics)… -23 to 122°F (-5 to 50°C)
Switching Point on Humidity Increase............................ 95% +/- 4% rh Humidity.............................................. 5 to 95% rh (Non-condensing)
Mechanical Conditions ..................................................... Class 3M2
Switching Differential (Fixed)................................. Approximately 5% rh
Transport to..................................................................... IEC 60721-3-2
Response Time in Static Air Climatic Conditions ........................................................... Class 2K2
From 80 to 99% rh ................................................ Maximum 3 minutes Temperature (Housing & Electronics)....... -13 to 150°F (-25 to 60°C)
From 99 to 80% rh ................................................ Maximum 3 minutes Humidity ............................................................................... <95% rh
Condensation ..........................................................Maximum 30 minutes Mechanical Conditions ..................................................... Class 2M2
Output Q11, Q12, Q14 Housing Materials and Colors....................... Thermoplastics, pure-white
Relay Output...................................... NO/NC Changeover Dry Contact Product Safety
Current Range at AC/DC 24V.......................................... 0.02 to 1 (1) A Automatic Electrical Controls for
Starting Current at AC/DC 24V........................... < /- 10 A for </- 20 ms Domestic Use and Similar Applications................................ EN 60730-1
Switching Capacity....................................... Minimum AC/DC 1V, 1 mA
Maximum A/DC,48V, 0.5 A Electromagnetic Compatibility
Immunity........................................................................... EN 61000-6-2
Degree of Protection of Housing ...............................IP 40 to EN 60529 Emissions......................................................................... EN 61000 6-3
Safety Class .................................................................... III to EN 60 730 CE Conformity
Connections Electromagnetic Compatibility............................................ 2004/108/EC
Mechanical .........................................Strap-on Band for Pipe Diameter Low-voltage Directive .......................................................... 2006/95/EC
0.39 to 3.94 inches (10 to 100 mm) Weight ............................................... 4.4 ounces (0.126 kg) w/Packaging
Electrical
Screw Terminals for................................. (2) 16 AWG or (1) 14 AWG
(max 2 × 1.5 mm2 or 1 × 2.5 mm2)
B-44

QXA2000 Product Ordering


Sensors

Description Part No.


Condensation Sensor QXA2000

B-1
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QFA Series

Electronic Room Hygrostats

QFA1000 Electronic Room Hygrostat QFA1001 Electronic Room


with Concealed Setpoint. Hygrostat with Exposed Setpoint.

Description Applications
B-45
The room hygrostats are used for controlling and For controlling humidification and dehumidification
monitoring relative humidity in ventilation or air equipment.
conditioning facilities. They ensure room humidity

Sensors
control within the selectable range of 30 to 90% relative
humidity by controlling humidification or dehumidification
equipment. They can also be used for monitoring minimum
or maximum humidity levels.

Features
• Hygrostat with single-pole microswitch
• Humidity measuring element made of stabilized plastic
• Setpoint knob for the upper switching point
• Mounts directly on the wall or on a recessed
conduit box
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QFA Series Electronic Room Hygrostats Specifications

Setpoint Range...................................................................... 30 to 90% rh Degree of Housing Protection.................................... IP 20 to EN 60 529


Temperature Safety Class........................................................................II to EN 60 730
Operating Range............................................32°F to 122°F (0°C to 50°C) Electrical Connection
Humidity Measuring Element...............................Stabilized Plastic Band Screw Terminals .............................................. .For Maximum 2 × 16 AWG
Control Mode......................................................................... Two-position Materials and Colors
Time Constant (v = 0.2 m/s)......................................... Approx. 5 minutes Base ...................................PPS, Fortron, Fiberglass Reinforced, Black
Cover.............................................................PC Lexan 940, Pure White
Setting Accuracy .......... + 5% rh (can be improved by calibrating on site) Humidity Measuring Element........................................................Plastic
Temperature Influence............................................................+ 0.5% rh/K Agency Approvals.......................................................UL listed for UL873
Humidity Calibration............................................ at 55% rh, 73°F (23°C) ......................................cUL Canadian Standard C22.2 No. 24-93
Long-term Stability.......................................... Approximately −1.5% rh/a .................................................................................CE conformity
.............................................................EMC directive 89/336/EEC
Type of Switch..................................... Potential-free Microswitch (SPDT)
Weight ...................................................................3.17 ounces (0.090 kg)
Contact Rating
Maximum...................................................................5 (3) A, 24 Vac/Vdc
Minimum..................................................................100 mA, 24 Vac/Vdc

QFA Series Electronic Room Hygrostats Product Ordering


Description Control Range Type of Control Part No.
B-46
Room 30 to 90% RH Humidity Switch with Concealed Setpoint QFA1000
Room 30 to 90% RH Humidity Switch with Exposed Setpoint QFA1001
Sensors

Accessories & Service Kits B-51

B-1
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QFM81

Electronic Duct Hygrostats

QFM81.21 Electronic Duct Hygrostat QFM81.2 Electronic Duct Hygrostat


with Internal Setpoint. with External Setpoint.

Description Applications
B-47
On/off hygrostat with microswitch, and temperature- For controlling humidification and dehumidification
compensated humidity sensor for temperature- equipment.
independent humidity measurements.

Sensors
Features
• Stabilized sensing strip
(good linearity, very stable even at high humidity,
insensitive to dust and contaminated air)
• Can be mounted in ventilating ducts or rooms
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

QFM81 Electronic Duct Hygrostats Specifications

Setpoint Range...................................................................... 30 to 90% rh Safety Class ...................................................................... II to EN 60 730


Control Mode....................................................................................On/off Electrical Connection
Type of Switch..................................... Potential-free Microswitch (SPDT) Screw Terminals ........................................................... 20 AWG Minimum
................................................................... 2 x 16 AWG Maximum
Contact Rating
Maximum .................................................................... 5 (3) A, 24 Vac/Vdc Materials and Colors
Minimum ....................................................................100 mA, 24 Vac/Vdc Sensing Element ...................................................................... .Polymer
Casing with Stem.............. PPS, Fortron 1140L6, Fiberglass Reinforced
Temperature Influence ...................................................... Compensated Cover ............................................................................... PC Lexan 940
Long-term Stability ......................................... Approximately −1.5% rh/a Transparent Cover (QFM81.21) ............................ PC Makrolon 2014R
Balancing ............................................................. At 55% rh, 73°F (23°C) Agency Approvals.......................................................UL listed for UL873
Time Constant (v = 0.2 m/s)......................................... Approx. 3 minutes ......................................cUL Canadian Standard C22.2 No. 24-93
Permissible Air Velocity ................................................................ 10 m/s Weight .......................................................... Approx. 12 ounces (0.34 kg)
Permissible Ambient Temperature
Operation .................................................. 32°F to 158°F (0°C to 70°C)
Storage/transport ................................... –22°F to 158°F (−30 to 70°C)
Degree of Housing Protection
FM81.2...................................................................... IP 30 to EN 60 529
QFM81.21 ............................................................... IP 55 to EN 60 529

QFM81 Electronic Duct Hygrostats Product Ordering


Description Control Range Type of Control Part No.
B-48
Duct 15 to 95% RH Humidity Switch with External Setpoint QFM81.2
Duct 15 to 95% RH Humidity Switch with Internal Setpoint QFM81.21
NOTE: Includes a mounting flange (for duct or wall mounting) and a sealing ring (for duct mounting).
Sensors

Accessories & Service Kits B-51

B-1
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

186 Series

Pneumatic Room and Duct Hygrostats

186 Room Hygrostat. 186 Duct Hygrostat.

Description Applications
B-49
The 186 Room and Duct Hygrostats are pneumatic The 186 Room and Duct Hygrostats provide control of
instruments sensitive to slight changes in relative humidity. relative humidity for comfort control in hospitals, schools
and office buildings.
Features

Sensors
• Adjustable sensitivity Application Drawings
• Sensitive hygroscopic membrane
• Includes temperature compensation
• Galvanized steel housing standard on duct model
• Models available for normal comfort range and high
limit range
• Room type comes complete with standard cover and
wall plate
• Duct type comes mounted inside a duct mounting box

Room Application.

Duct Application.
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

Pneumatic Room and Duct Hygrostats Specifications

Sensitivity ......................................................................1/4 to 4 psi/% RH Dimensions


Normal Supply Pressure ..................... 15 to 25 psi (103 kPa to 172 kPa) Chassis......................................................... 2.9" H x 1.75" W x 1.13" D
(73.66 mm W x 44.45 mm H x 28.70 mm D)
Maximum Supply Pressure ............................................30 psi (207 mm) Room........................................................................... 2.16" W x 3.34" H
Air Consumption ............................................................. 15 scim (4 ml/s) (55 mm W x 85 mm H)
Effect of 10°F Temperature Change .................................Shift of 1% RH Duct .................................................................. 4.5" W x 5.88" H x 6" D
(114 mm x W 149 mm H x 152 mm D)
Effect of 5 psi Supply Pressure
Change (mid sensitivity) ................................................. 7.0 min./vol unit Standard Room Cover ..............................................Desert Beige, plastic
Duct Box .................................................... Extends 6" (152 mm) into duct Shipping Weights
186-0013 & 186-0019.................................................. 0.84 lb. (0.38 kg)
Air Connections 186-0087; 186-0088; 186-0090; 186-0091.......................3.3 lb. (1.5 kg)
Duct ........................................................... Barb fitting for 1/4" (64 mm)
OD polyethylene tubing
Room............................................ 5/32" (4 mm) OD polyethylene tubing

Pneumatic Room and Duct Hygrostats Product Ordering


Part No.
Direct Reverse
Description Control Range Type of Control Control Action Control Action
Room 20 to 90% RH Humidification/Dehumidification 186-0013 186-0019
Duct 20 to 90% RH Humidification/Dehumidification 186-0087 186-0088
B-50 Duct 55 to 95% RH High Limit — 186-0090
Duct 25 to 65% RH Room Comfort — 186-0091
Sensors

Accessories & Service Kits B-51

B-1
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

Accessories &
Service Kits
Table of Contents
Product Page #

Sensors

Mounting Devices/Kits B-52

Replacement Parts B-52 — B-55

Sun Shield B-54

Well B-54

Hygrostat

Repair Kits B-54

B-51

Sensors
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

Accessories & Service Kits

Description Product Group Quantity Part No.


Sensors
Single Adapter Base Kit. T, RH & RH/T Sensors
• Beige 1 544-782A
• White 1 544-782B

Double Adapter Base Kit. T, RH & RH/T


• Beige 1 544-783A

• White 1 544-783B

Extender Ring Kit. T, RH & RH/T


• Beige 1 544-785A
• White 1 544-785B

B-52
Non-Conduit Rough-in Kit. T, RH & RH/T Sensors 1 544-784
Comes with plastic GWB protrusion
piece which is discarded when
wall sensor is installed.
Sensors

Metal Gym Guard. RT Sensors 1 182-621


Desert Beige
B-1

Electrical Box (2 x 4) T, RH & RH/T Sensors Pkg. of 5 192-506


Adapter Plate Kit.

Electrical Box (2 x 4) T, RH & RH/T Sensors Pkg. of 5 192-507


Adapter Base. (low profile)

Adapter Base. T, RH & RH/T Sensors 1 192-307


Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

Accessories & Service Kits

Description Product Group Quantity Part No.


Sensors
Adapter Frame. RT Sensors 1 192-308

Mounting Strap. RT Sensors 1 536-666


For mounting Room Sensor on
standard light switch plate.

Adapter Plug. RT Sensors 1 540-142


For plugging in Room Sensor &
Portable Operator’s Terminal into
Controller.

Fixing Bracket for Remote Mounting. Q Series Pressure 1 AQB22.1


Made from die-cast Aluminum.

B-53
Mounting Kit. Q Series Pressure 1 AQB51.1

Sensors
Conduit Assembly Kit. 599 Series Diff. Pressure 1 590-500
Sensors

Replaceable Humidity Q Series Room Humidity 1 AQF3051


Sensing Element. (Series 1000 Housing
2% versions only. Only)

Humidity Sensor Filter Cap. Q Series Duct/Outdoor 1 AQF3101


Air Humidity

Replaceable 2% Q Series Duct/Outdoor 1 AQF3150


Humidity Sensor Tip. Air Humidity

Replaceable 2% Certified Q Series Duct/Outdoor 1 AQF4150


Humidity Sensor Tip. Air Humidity
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

Accessories & Service Kits

Description Product Group Quantity Part No.


Sensors
Replacement Flange Kit. Q Series Duct Humidity 1 74 662 0068 0

Sun Shield. Q Series Outdoor 1 AQF3100


Air Humidity

Stainless Steel Well. Pipe Temp. Sensors


0.26"D x 2 1/2"L (18 mm D x 64 mm L) 1 AQE2000.005
0.26"D x 4"L (18 mm D x 102 mm L) 1 184-120
0.26"D x 4"L (18 mm D x 102 mm L) 1 AQE2000.010

B-54 0.26"D x 6"L (18 mm D x 152 mm L) 1 AQE2000.015


186
Hygrostat Restrictor Repair Kit. 186 Material 180-893
Includes enough restrictor for plates for 10
Sensors

and upper and lower Hygrostats Hygrostats


gaskets.

Membrane Element Kit. 186 1 186-062


Replaces membrane element.
Contains one element assembly,
screws, nuts, and lock washers.
B-1

Wall Box Rough-In. 186


For 2-pipe dual 1/8" (3 mm) OD 1 192-478
copper with plaster plate.
8' (2 m) long, belled to 3/16" (5 m)
OD with thermostat chassis plug-in
adapters for easy maintenance.
3-pipe dual 1/8" (3 mm) OD copper 1 192-498
with plaster plate.
8' (2 m) long, belled to 3/16" (5 m)
OD with thermostat chassis plug-in
adapters for easy maintenance.

Wall Box Rough-In. 186


For 1- or 2-pipe dual 1/4" (6 mm) 1 192-480
OD polyethylene with plaster plate.
10' (2 m) long. With thermostat chassis
plug-in adapters for easy maintenance.

3-pipe dual 1/4" (6 mm) 1 192-499


OD polyethylene with plaster plate.
8' (2.4 m) long. With thermostat chassis
plug-in adapters for easy maintenance.
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

Accessories & Service Kits

Description Product Group Quantity Part No.


186
Mounting Clips, Spacer and 186 Package 182-685
Template for finished drywall. of 10

Stud Mounting Bracket and 186 1 192-482


Dual Copper Tubing.
Belled to 3/16" (5 mm) OD with plug-in
adapters for easy maintenance.

Metal/Wood Stud Bracket. 186 Package 182-683


Drywall rough-in. Wall mounting kit for of 5
either wood or metal stud. This kit does
not offer a conduit connection and is
to be used for open wire projects. Kit
comes 5/box.
Dual 1/8" (3 mm) OD Copper Tubing 186 1 192-479
with Plug-in Adapters. B-55
For 1- or 2-pipe.
Split for 3-pipe.

Sensors
Plug-in Adapter. 186 Package 192-875
Includes Tee 20 scim restrictor for of 10
1-pipe.

Installation Plate for Conduit Series 1000 1 981-344


Single gang electrical box mounted
plate with a plastic GWB protrusion
which is removed at the time of wall
sensor installation. This kit is intended
for conduit-installed projects.
Distributed By: M&M Control Service, Inc. [Link]/[Link] 800-876-0036 847-356-0566

Notes

B-56
Sensors

B-1

Siemens sensors are strong,


accurate, and reliable.
Whether your applications are for warehouses or clean rooms,
Siemens has decades of sensor experience designed into every unit.
Fully tested and in-depth applications expertise guarantee the precise
performance of our sensors and full compatibility with all Siemens
HVAC controllers and building automation systems.

You might also like