LA 205-S/SP1 Current Transducer Specs

The Current Transducer LA 205-S/SP1 is designed for electronic measurement of various current types with galvanic isolation between primary and secondary circuits, supporting a nominal primary current of 200 A. It features high accuracy, low temperature drift, and a wide frequency bandwidth, making it suitable for applications like AC drives and UPS systems. The device operates within a temperature range of -10 to +85 °C and includes specific mechanical characteristics for installation.

Uploaded by

Nahid Rahmani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
18 views2 pages

LA 205-S/SP1 Current Transducer Specs

The Current Transducer LA 205-S/SP1 is designed for electronic measurement of various current types with galvanic isolation between primary and secondary circuits, supporting a nominal primary current of 200 A. It features high accuracy, low temperature drift, and a wide frequency bandwidth, making it suitable for applications like AC drives and UPS systems. The device operates within a temperature range of -10 to +85 °C and includes specific mechanical characteristics for installation.

Uploaded by

Nahid Rahmani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Current Transducer LA 205-S/SP1 IPN = 200 A

For the electronic measurement of currents : DC, AC, pulsed...,


with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).

16140
Electrical data
IPN Primary nominal r.m.s. current 200 A Features
IP Primary current, measuring range 0 .. ± 300 A
ÎP max Measuring overload 1) 600 A • Closed loop (compensated) current
RM Measuring resistance @ TA = 70°C TA = 85°C transducer using the Hall effect
RM min RM max RM min RM max • Insulated plastic case recognized
according to UL 94-V0
with ± 12 V @ ± 200 A max 0 68 0 66 Ω
@ ± 300 A max 0 33 0 30 Ω • Patent pending.
with ± 15 V @ ± 200 A max 5 95 5 93 Ω
@ ± 300 A max 5 50 5 49 Ω Special feature
ISN Secondary nominal r.m.s. current 100 mA • Connection to secondary circuit on
KN Conversion ratio 1 : 2000 Faston 6.3 x 0.8 mm.
VC Supply voltage (± 5 %) ± 12 .. 15 V
IC Current consumption 20 (@ ± 15 V ) + IS m A Advantages
Vb R.m.s rated voltage 2), safe separation 1625 V
basic isolation 3250 V • Excellent accuracy
• Very good linearity
Accuracy - Dynamic performance data • Low temperature drift
XG Overall accuracy @ IPN , TA = 25°C ± 0.8 % • Optimized response time
ε L
Linearity error < 0.1 % • Wide frequency bandwidth
• No insertion losses
Typ Max
• High immunity to external
IO Offset current @ IP = 0, TA = 25°C ± 0.15 mA
interference
IOM Residual current 3) @ IP = 0, after an overload of 3 x IPN ± 0.50 mA
• Current overload capability.
IOT Thermal drift of IO - 10°C .. + 85°C ± 0.15 ± 0.30 mA
tra Reaction time @ 10 % of IPN < 500 ns Applications
tr Response time 4) @ 90 % of IPN <1 µs
di/dt di/dt accurately followed > 100 A/µs • AC variable speed drives and servo
f Frequency bandwidth (- 3 dB) DC .. 100 kHz motor drives
• Static converters for DC motor drives
General data • Battery supplied applications
TA Ambient operating temperature - 10 .. + 85 °C • Uninterruptible Power Supplies
(UPS)
TS Ambient storage temperature - 40 .. + 90 °C
RS Secondary coil resistance @ TA = 70°C 35 Ω • Switched Mode Power Supplies
(SMPS)
TA = 85°C 37 Ω
m Mass 110 g • Power supplies for welding
applications.
Standards EN 50178 : 1997
Notes : 1) 3 mn/hour @ VC = ± 15 V, R M = 5 Ω
2)
Pollution class nr 2. With a non insulated primary bar which fills the
through-hole
3)
The result of the coercive field of the magnetic circuit
4)
With a di/dt of 100 A/µs.
060531/3

LEM Components w w [Link]


Dimensions LA 205-S/SP1 (in mm. 1 mm = 0.0394 inch)

Front view Left view

Connection

Top view

Mechanical characteristics Remarks

• General tolerance ± 0.5 mm • IS is positive when IP flows in the direction of the arrow.
• Transducer fastening 2 holes ∅ 5.5 mm • Temperature of the primary conductor should not exceed
2 M5 steel screws 100°C.
Fastening torque max. 4 Nm or 2.95 Lb. - Ft. • Dynamic performances (di/dt and response time) are best
• Primary through-hole 23 x 18 mm with a single bar completely filling the primary hole.
• Connection of secondary Faston 6.3 x 0.8 mm

LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.