0% found this document useful (0 votes)
74 views4 pages

WSA Datasheet en

The WSA is an outdoor sensor designed to measure relative humidity and temperature, featuring a radiation shield to protect against environmental factors. It is available in two types, WSA VV and WSA AA, and requires installation by authorized personnel while adhering to safety regulations. The sensor has specific technical data, including measuring ranges, accuracy, and power supply requirements, and must be disposed of according to EU regulations.

Uploaded by

Ivan Ivkovic
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
74 views4 pages

WSA Datasheet en

The WSA is an outdoor sensor designed to measure relative humidity and temperature, featuring a radiation shield to protect against environmental factors. It is available in two types, WSA VV and WSA AA, and requires installation by authorized personnel while adhering to safety regulations. The sensor has specific technical data, including measuring ranges, accuracy, and power supply requirements, and must be disposed of according to EU regulations.

Uploaded by

Ivan Ivkovic
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

WSA

Outdoor sensor for relative humidity and temperature

Datasheet
Subject to technical alteration
Issue date: 27.03.2024 • A140

» APPLICATION
Protected temperature and humidity sensor for outside applications. The Radiation shield protects the outside sensors from rain and radiated heat.
With the curved shape and color of the plates air flow is able to move across the sensors to keep radiated temperatures from rooftops and
surrounding surfaces from affecting humidity readings.

» TYPES AVAILABLE
Weather protection - outdoor humidity sensor temperature + humidity – active
• WSA VV
• WSA AA

» SECURITY ADVICE – CAUTION


The installation and assembly of electrical equipment should only be performed by authorized personnel.

The product should only be used for the intended application. Unauthorised modifications are prohibited! The product must not
be used in relation with any equipment that in case of a failure may threaten, directly or indirectly, human health or life or result in
danger to human beings, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating
equipment.

Please comply with


• Local laws, health & safety regulations, technical standards and regulations
• Condition of the device at the time of installation, to ensure safe installation
• This data sheet and installation manual

» PRODUCT TESTING AND CERTIFICATION

Declaration of conformity
The declaration of conformity of the products are available on our website
[Link]

» NOTES ON DISPOSAL
The crossed-out wheelie bin symbol indicates that the product or removable batteries must not be disposed of with household or
commercial waste. Within the EU, you are legally obliged to dispose of the product separately and appropriately in accordance
with the national laws of your country. Alternatively, please contact your supplier or Thermokon Sensortechnik GmbH. Further
information can be found at: [Link]

Thermokon Sensortechnik GmbH, Platanenweg 1, 35756 Mittenaar, Germany · tel: +49 2778 6960-0 fax: -400 [Link] email@[Link]
WSA_Datasheet_en © 2024
Page 2 / 4 Issue Date: 27.03.2024

» BUILD-UP OF SELF-HEATING BY ELECTRICAL DISSIPATIVE POWER


Sensors with electronic components always have a dissipative power, which affects the temperature measurement of the ambient air. The
dissipation in active temperature sensors shows a linear increase with rising operating voltage. This dissipative power has to be considered when
measuring temperature. In case of a fixed operating voltage (±0,2 V) this is normally done by adding or reducing a constant offset value.
Thermokon transducers can be operated with variable operating voltages. The transducers are set at the factory with a reference operating voltage
of 24 V =.
At this voltage, the expected measuring error of the output signal will be the least. Other operating voltages, can cause a measurement deviation
changing power loss of the sensor electronics.
A recalibration can be carried out directly on the unit or via a software variable (app or bus).
Remark: Occurring draught leads to a better carrying-off of dissipative power at the sensor. Thus temporally limited fluctuations might
occur upon temperature measurement.

» APPLICATION NOTICE FOR HUMIDITY SENSORS


At regular environmental condition, it is recommended to calibrate the sensor annually to check the compliance with the accuracy
required in the application. The following conditions can damage the sensor element or lead in long therm to loss of the specified
accuracy:
• Mechanical stress
• Contamination (e.g. dust / fingerprints) Do not touch the sensor
• Aggressive chemicals elements!
• Ambient conditions (e.g. condensation on measuring element)
Re-calibration or exchange of the sensor element are not subject of the general warranty.

» TECHNICAL DATA
Measuring values temperature, humidity (humidity output configurable)

Output voltage VV: 2x 0..10 V or 0..5 V, configurable via Jumper, min. load 10 kΩ

Output ampere AA: 2x 4..20 mA, max. load 500 Ω

Output passive (*optional) VVS | AAS: optional, PT100/PT1000/NI1000/NI1000TK5000/NTC10K... and other sensors on request

Power supply VV: 15..24 V = (±10%) or 24 V ~ (±10%) SELV AA: 15..24 V = (±10%) SELV

Power consumption VV: typ. 0,4 W (24 V =) | 0,8 VA (24 V ~) AA: typ. 1 W (24 V =)

Measuring range temp. VV | AA passive


adjustable at the transducer: -20..+80 | 0..+50 | - depending on used sensor
40..+60 | -15..+35 °C
default setting: -20..+80 °C

Measuring range humidity 0..100% rH non-condensing

Measuring range abs. hum. adjustable at the transducer: 0..50 | 0..80 g/m³, default setting: 0..50 g/m³

Measuring range enthalpy 0..85 KJ/kg

Measuring range dew point adjustable at the transducer: 0..50 | -20..+80 °C, default: 0..50 °C

Accuracy temperature VV | AA passive


±0,3 K (typ. at 21 °C within default measuring range) typ. ±0,3 K (typ. at 21 °C), depending on used
sensor

Air speed max. 12 m/s

Accuracy humidity ±2% between 10..90% rH (typ. at 21 °C)

Enclosure enclosure USE-S, PC, pure white

Protection enclosure sensor head


IP65 according to EN 60529 IP30 according to EN 60529

Cable entry Flextherm M20, for wire Ø=4,5..9 mm, removable

Connection electrical removable plug-in terminal, max. 2,5 mm²

Pipe PA6, black, Ø=19,5 mm, length=140 | 270 | 400 mm

Ambient condition -20..+70 °C, short term condensation

Mounting wall mounting or mounting to a mast tube

Notes additional passive sensor available (type VVS | AAS)

Thermokon Sensortechnik GmbH, Platanenweg 1, 35756 Mittenaar, Germany · tel: +49 2778 6960-0 fax: -400 [Link] email@[Link]
WSA_Datasheet_en © 2024
Issue Date: 27.03.2024 Page 3 / 4

» CONNECTION PLAN
Offset Terminal assignment Device configuration
Temperature Jumper 1-2 (humidity)

relative enthalpy absolute dew point


humidity humidtye

Jumper1-5
1 °C °F (additional information below)
2 0..10V 0..5 V VV, VVS only
Humidity relative humidity: 0..100%
absolute humidity: 0..50 g/m³
enthalpy: 0..85 kJ/kg
dew point: 0..+50 °C
3
relative humidity: 0..100%
absolute humidity: 0..80 g/m³
VV, VVS AA, AAS enthalpy: 0..85 kJ/kg
0..10V | 0..5V 4..20mA dew point: -20..+80 °C

-40°C..+60°C 0°C..+50°C

-20°C..+80°C -15°C..+35°C
abs. humidity: ±3g/m³ EN-US datasheet with
enthalpy: ±3 kJ/kg additional information
dew point: ±3 K about °F

AOU1: Humidity AOI1: Humidity


AOU2: Temperature AOI2: Temperature

Clamp ST+ | ST- : passive sensor (VVS | AAS)

The adjustment of the measuring ranges is made by changing the jumpers in a de-energized state. The output value of the new measuring range
is available after 2 seconds. fig. (Measuring range and offset adjustment, default settings: -20 °C..+80 °C | 0 K)
Note (type WSA AA)
When only using the temperature output, the humidity output must always be connected to mass/GND of the analog input module.

» MOUNTING ADVICES

» USE ENCLOSURE WITH UV AND WEATHER RESISTANCE


After some time, outdoor mounted plastics can lose their color and quality. Therefore, all USE housings are made of special white polycarbonate
(PC). The light-stable colorants and additives are used to achieve optimum protection of the polymer while maintaining color stability. The titanium
dioxide used is specially developed for polycarbonate and offers excellent UV protection through the reflection of the entire light spectrum including
the UV component by 340 nm. This effectively counteracts the otherwise occurring photochemical polymer degradation. The colors stay full for a
long time without fading. The material is also resistant to cold and frost.

Thermokon Sensortechnik GmbH, Platanenweg 1, 35756 Mittenaar, Germany · tel: +49 2778 6960-0 fax: -400 [Link] email@[Link]
WSA_Datasheet_en © 2024
Page 4 / 4 Issue Date: 27.03.2024

» APPLICATION NOTICE
After a certain time, dirt in the air can collect on the filter and then adversely affect the operation of the sensor. Under normal ambient condition an
annual maintenance is recommended. Rinse the filter after cleaning with distilled water and dry it using clean oil-free air or nitrogen. Extremely
contaminated filters should be replaced. At extreme ambient conditions, e.g. corrosive gases, the humidity sensor may have to be changed.

» DIMENSIONS (MM)

» ACCESSORIES (OPTIONAL)
Filter stainless steel, wire mesh (spare part) Item No. 231169
Weather protection for FTK, FTK+, WSA (replacement) Item No. 625241
Sealing insert M20 USE white, 2x Ø=7 mm (for 2 wire; PU 10 pieces) Item No. 641333

Thermokon Sensortechnik GmbH, Platanenweg 1, 35756 Mittenaar, Germany · tel: +49 2778 6960-0 fax: -400 [Link] email@[Link]