NOTES
[Link] structural drawing are to be read in conjuction with
the architectural drawings
[Link] depth might change to suit subsoil condition as
directed by the engineer
[Link] and fine aggregates shall be clean with no foreign
bodies
[Link] shall be ordinary portland cement,if imported cube
test shall be done to approves the quality of cement
[Link] concrete shall be grade 25 with maximum
aggregate size 1inch[25mm]
[Link] concrete shall be grade 15
[Link] reinforced should be high yield tensile steel with yield
strength of 460N/mm2
[Link] reinforced shall be free from rust impurities
[Link] from each lot shall be tested and result
submited to the engineer before use
[Link] otherwise specified minimum cover
+6.75m Roof level reinforcement shall be as follows
slab and beam 25mm
450
column 30mm
foundation in dry soil 50mm
foundation in water logging soil 175mm
11. Reinforced steel of varying length and curved shape
12T8-02-175
are to be bent to suit structural shape
6T16-05 [Link] mortar for construction should be of designation{iii}
13. The minimum compressive strength of the construction
2700
blocks should be 2.8N/mm2
75mm kicker
14. All dimensions are in mm otherwise where specified and
dimensions are to counterchecked on site
[Link] not scale from the drawings ,any descripancy
5T8-02
800
to be reported to the engineer for clarifications and
reconsiliations
450
12T8-02-175
6T16-04
2700
CLIENT DETAILS
200
115 115
75mm kicker
230
1
130
130
5T8-02
800
200 PROJECT TITTLE:
+0.45m Ground floor
24T8-175
450
175 125 L=850 (Hook:100)
6T16-03 300 DRAWING TITTLE:
1200
9T8-175
CONSULTING COMPANY STAMP
C3 DRAWN BY: CHECKED BY: STAMP
400
(230x300) EZ PHARES
0733333530
ENG [Link]
DATE AGUST 2024
1200
C3-52 Nos -{230x300}
COLUMN REINFORCEMENT DETAILS AND SECTIONS SCALE: DRAWING NO REVISION :
1:75&1:100