CATHODIC PROTECTION CABLES
50 YEARS EXPERIENCE IN CATHODIC PROTECTION
Electrolytic Anti-fouling
TEST STATIONS
DATA SHEET
HMWPE Cable
HMWPE cable utilizes stranded copper conductors that are
Copper
insulated with a high molecular weight polyethylene (HMWPE)
Conductor
compound. It provides strong resistance to abrasion, crushing,
chemicals, oil, moisture, and other elements.
HMWPE Jacket
Cross Section Strands Conductor Dia. Insulation Thk. Overall Dia. D.C. Resistance(20°C) Current Rating
2.5 mm² 7 1.70 mm 2.8 mm 7.7 mm 7.41 Ω/km 18 A
4 mm² 7 2.20 mm 2.8 mm 8.2 mm 4.63 Ω/km 24 A
6 mm² 7 1.04 mm 2.8 mm 8.8 mm 3.08 Ω/km 30 A
10 mm² 7 1.35 mm 2.8 mm 9.7 mm 1.83 Ω/km 42 A
16 mm² 7 1.70 mm 2.8 mm 10.7 mm 1.15 Ω/km 56 A
25 mm² 7 2.14 mm 2.8 mm 12.1 mm 0.727 Ω/km 73 A
35 mm² 7 2.52 mm 2.8 mm 13.2 mm 0.524 Ω/km 90 A
50 mm² 19 1.78 mm 3.18 mm 15.3 mm 0.387 Ω/km 145 A
70 mm² 19 2.14 mm 3.18 mm 17.1 mm 0.268 Ω/km 185 A
sales@[Link] | [Link]
TEST STATIONS
DATA SHEET
PVDF/HMWPE Cable
This cable is composed of stranded copper wire covered by two Copper
layers of insulation. The outer jacket is made from high molecular Conductor
weight [Link] inner insulation is composed of PVDF
fluorocopolymer. It can be installed directly in native soils or PVDF Insulation
submerged in fresh, brackish or salt waters. The cable is ideal for
deep anode bed installations where chlorine and hydrogen
HMWPE Jacket
gases are generated.
Cross Section Strands Conductor Dia. Insulation Thk. Overall Dia. D.C. Resistance(20°C) Current Rating
6 mm² 7 1.04 mm 0.65 mm 7.7 mm 3.08 Ω/km 30 A
10 mm² 7 1.35 mm 0.65 mm 8.7 mm 1.83 Ω/km 42 A
16 mm² 7 1.70 mm 0.65 mm 9.8 mm 1.15 Ω/km 56 A
25 mm² 7 2.14 mm 0.65 mm 11.0 mm 0.727 Ω/km 73 A
35 mm² 7 2.52 mm 0.65 mm 12.1 mm 0.524 Ω/km 90 A
50 mm² 19 1.78 mm 0.65 mm 12.4 mm 0.387 Ω/km 145 A
XLPE/PVC Cable
XLPE/PVC cable is the most common used cable in cathodic Copper
Conductor
protection systems. It is composed of copper core covered with
XLPE Insulation layer which has excellent chemical resistance
and low temperature [Link] jacket layer is made of PVC XLPE Insulation
material which enhance its dielectric strength, waterproofness
and flame retardancy . PVC Jacket
Cross Section Strands Conductor Dia. Insulation Thk. Overall Dia. D.C. Resistance(20°C) Current Rating
6 mm² 7 1.04 mm 0.7 mm 7.3 mm 3.08 Ω/km 30 A
10 mm² 7 1.35 mm 0.7 mm 8.2 mm 1.83 Ω/km 42 A
16 mm² 7 1.70 mm 0.7 mm 9.3 mm 1.15 Ω/km 56 A
25 mm² 7 2.14 mm 0.9 mm 11.0 mm 0.727 Ω/km 73 A
35 mm² 7 2.52 mm 0.9 mm 12.1 mm 0.524 Ω/km 90 A
50 mm² 7 2.98 mm 1.0 mm 13.1 mm 0.387 Ω/km 145 A
70 mm² 14 2.58 mm 1.1 mm 15.1 mm 0.268 Ω/km 185 A
sales@[Link] | [Link]
Worldwide
Service Network
Our worldwide network of sales and
service centers can provide immediate
advice and assistance on the complete
range of products.
Global Headquarter
3115 Fry Road Ste 303, Katy, Texas
77449, United States
Email: sales@[Link]
Tel: +1 (281) 501 8398 / +1 (713) 799 3884
[Link]
UK Office
Tatham Street, Hendon, Sunderland
SR1 2AG, United Kingdom
Email: sales@[Link]
Tel: +44 (0) 191 510 8843
Fax: +44 (0) 191 514 7749
[Link]
Asia Pacific Office
120 Lower Delta Road, #07-13 Cendex
Centre, Singapore 169208
Email: inquiries@[Link]
Tel: +65 6715 1514
View Our Website Follow Us On LinkedIn