0% found this document useful (0 votes)
71 views1 page

Retaining Wall Proposal for Abutment A1

The document outlines the design specifications for a retaining wall at Abutment A1, including dimensions and materials such as M15 concrete and hand-packed stone backfill. It adheres to IRC standards and includes notes on construction methods and parallel work with the abutment. The project is part of the Double Lane Steel Truss Bridge for the Sunni Dam HEP in Himachal Pradesh, commissioned by SJVN.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
71 views1 page

Retaining Wall Proposal for Abutment A1

The document outlines the design specifications for a retaining wall at Abutment A1, including dimensions and materials such as M15 concrete and hand-packed stone backfill. It adheres to IRC standards and includes notes on construction methods and parallel work with the abutment. The project is part of the Double Lane Steel Truss Bridge for the Sunni Dam HEP in Himachal Pradesh, commissioned by SJVN.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

5000

Return Wall of A1 Abutment (300mm)

500

Inside
Outside

Slope 30mm pe
10600

8600

3
e 1:
Slop

tre r me
3500
4200
2200
Sectional Elevation (Left Bank - Downstream Side)

2200
3500
500

SLOPE
(1:36)

NOTES:
5000
1. Backfill: The backfill layer immediately behind the wall should
consist of hand packed stone or some granular material as shown
in the drawing. Remainder of the backfill should be rammed in
150 mm thick layers sloping towards the back of the wall. As per
IRC 48.

2. The concrete of the retaining wall shall be M15.

3. The retaining wall shall be in accordance to IRC-78 as per the


specifications of the contract.

4. The retaining wall shall be done Parallelly alongwith the backfill of


Abutment A1.
D

t a
A

r a
O

S t
R

Rock y

Design, Engineering. Supply. Fabrication. Transportation. Erection,


PROJECT load testing and painting etc. complete in all respect of Double Lane
Steel Truss Bridge Class 70R/Class AA/Class A/Class Special Vehicle
(SV) including abutments with deck level at EL +680m and span of
113 m across river Satluj D/s of proposed Dam Site Khaira for Sunni
Dam HEP (382 MW) Distt. Shimla/Mandi (HP).

CLIENT SJVN- SUNNI HEP

CONTR. P&R P & R INFRAPROJECTS LIMITED,


GROUP CHANDIGARH.

PROPOSAL FOR RETAINING WALL FOR


TITLE
ABUTMENT A1

DRAWN HARMAN DATE 04.11.2024 SCALE : NTS

CHKD. APPD.
[Link]. PRIL/SJVN/A1/001 REV-0

You might also like