EL.
CO Micro2 Mechanical Installation – Connection of the Lift Control Panel
4.4 SGV2 BOARD (VOICE ANNAUNCEMENT)
LED
24V Input power supply 24Vdc, always ON
When communication with main board is OK this
OK led flashing
TERMINALS
+24,-24 Power supply 24Vdc
CANH,
Communication CAN BUS with main board
CANL
1 Speaker 1W,8Ω
SP,SP (Don’t connect 2 speakers will damage the board)
Adjust the volume from the menu
All voice messages can
stored in microSD
memory card.
All announcement files
must be:
8-bit PCM or 16-bit PCM
& sampling frequency:
44100Hz ή 48000Hz
*In menu FLOOR
each floor message
announcement is
possible to adjust
separately
**In menu NIGHT (from
22:00 to 7:00 a.m.)
Is possible to adjust the
volume of SGV2.
If adjust 10 then the
volume all day will be the
same. If adjust 0 from
22:00 to 7:00a.m. volume
will turn off. If adjust 5 the
volume will be at 50%.
[Link] HELLAS S.A. CONTROL SYSTEMS FOR LIFTS [Link] 35