0% found this document useful (0 votes)
478 views171 pages

Diagnostic User'S Guide: Broadcom Netxtreme Ethernet Adapter

Uploaded by

5290 Agx
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
478 views171 pages

Diagnostic User'S Guide: Broadcom Netxtreme Ethernet Adapter

Uploaded by

5290 Agx
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Broadcom NetXtreme Ethernet Adapter

Diagnostic User’s Guide

B57diag DOS Version [Link]


B57diag UEFI Version [Link]

page 1
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Copyright © 2000-2009 Broadcom Corporation


All Rights Reserved

No part of this document may be reproduced, in any form or by any means, without permission in
writing from Broadcom Corporation.
Broadcom Corporation reserves the right to make changes to the products or information contained in
this document without notice. No liability is assumed as a result of their use or application. No rights
under any patent accompany the sale of any such products or information.
Epigram, InsideLine, and iLine10 are trademarks of Broadcom Corporation.

Broadcom Corporation
5300 California Ave
Irvine, CA 92617
[Link]

page 2
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

TABLE OF CONTENTS
1 INTRODUCTION................................................................................................................................. 11

2 PREREQUISITES ................................................................................................................................ 12

3 DIAGNOSTIC TESTS.......................................................................................................................... 13
3.1 TEST NAMES ................................................................................................................................... 13
3.2 ERROR CODES ................................................................................................................................. 14
3.3 TEST DESCRIPTIONS ........................................................................................................................ 14
3.3.1 A1. Indirect Register Test........................................................................................................... 14
3.3.2 A2. Control Register Test........................................................................................................... 14
3.3.3 A3. Interrupt Test ....................................................................................................................... 15
3.3.4 A4. BIST ..................................................................................................................................... 15
3.3.5 A5. PCI Cfg Register Test .......................................................................................................... 15
3.3.6 A6. Serial Number Reg Test ....................................................................................................... 15
3.3.7 A7. Power Register Test............................................................................................................. 15
3.3.8 B1. Scratch Pad Test.................................................................................................................. 16
3.3.9 B2. BD SRAM Test ..................................................................................................................... 16
3.3.10 B3. DMA SRAM Test ............................................................................................................. 16
3.3.11 B4. MBUF SRAM Test........................................................................................................... 17
3.3.12 B5. MBUF SRAM via DMA Test ........................................................................................... 17
3.3.13 B6. External SRAM Test ........................................................................................................ 17
3.3.14 B7. CPU GPR Test ................................................................................................................ 17
3.3.15 C1. EEPROM Test ................................................................................................................. 18
3.3.16 C2. CPU Test ......................................................................................................................... 18
3.3.17 C3. DMA Test ........................................................................................................................ 18
3.3.18 C4. MII Test ........................................................................................................................... 18
3.3.19 C5. VPD Test ......................................................................................................................... 19
3.3.20 C6. ASF Test .......................................................................................................................... 19
3.3.21 C7. ROM Expansion Test ...................................................................................................... 20
3.3.22 C8. CPU Fetch Test............................................................................................................... 20
3.3.23 D1. Mac Loopback Test......................................................................................................... 20
3.3.24 D2. Phy Loopback Test.......................................................................................................... 20
3.3.25 D3. RJ45 Loopback Test........................................................................................................ 21
3.3.26 D4. 1G False Carrier Test..................................................................................................... 21
3.3.27 D5. MII Miscellaneous Test................................................................................................... 21
3.3.28 D6. MSI Test .......................................................................................................................... 21
3.3.29 D7. E-Switch Test .................................................................................................................. 22
3.3.31 D8. SADB Test ....................................................................................................................... 22
3.3.32 D9. IPsec Loopback Test ....................................................................................................... 22
3.3.33 E1. 1G Wire Open/Short (** ZERO LEN LB RJ45 **) Test ................................................. 22
3.3.34 F1. Indirect APE Ctrl Register Test...................................................................................... 23
3.3.35 F2. APE Control Register Test ............................................................................................. 23
3.3.32 F3. Indirect APE Peripheral Register Test........................................................................... 23
3.3.33 F4. APE Peripheral Register Test ........................................................................................ 23
3.3.34 F5. APE Scratch Pad Test .................................................................................................... 23
3.3.35 F6. APE Shared Memory Test .............................................................................................. 24
3.3.36 F7. APE Shared Memory Indirect Access Test..................................................................... 24
3.3.37 F8. APE Mutex Register Test................................................................................................ 24
3.3.38 F9. APE Timers Test............................................................................................................. 25
3.3.39 G1. APE CPU Memory Test ................................................................................................. 25
3.3.40 G2. APE CPU Packet Test.................................................................................................... 25

page 3
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

3.3.41 G3. APE CPU SMBus Loopback Test .................................................................................. 26


3.3.42 G4. APE CPU GPIO Register Test....................................................................................... 26
3.3.43 G5. APE CPU Event Register Test ....................................................................................... 26
3.3.44 G6. APE CPU Mutex Register Test ...................................................................................... 26
3.3.45 G7. APE CPU Timers Test ................................................................................................... 26
3.3.46 G8. APE CPU GRC Reset Test............................................................................................. 27
3.3.47 G9. APE USB Test (UEFI only)........................................................................................... 27
4 COMMAND LINE OPTION PARAMETERS .................................................................................. 28

5 RECOVER DEVICE FROM CORRUPT NVAM ............................................................................. 43

6 [Link] FORMAT ................................................................................................................... 44

7 USER INTERFACE COMMANDS .................................................................................................... 49

8 SPECIAL INSTRUCTION .................................................................................................................. 55

9 SAME SYSTEM SEND/RESPOND TEST......................................................................................... 56


9.1 IDENTIFYING A REFERENCE DEVICE ................................................................................................. 56
9.2 TESTING THE DUT AGAINST THE REFERENCE DEVICE ..................................................................... 56
9.3 OTHER OPTIONS FOR THE SEND/RESPOND TEST .............................................................................. 56
10 TEST AND FUNCTIONS DESCRIPTION ................................................................................... 57
10.1 VPDWRITE........................................................................................................................................ 57
10.2 VPDREAD ......................................................................................................................................... 57
10.3 VPDINFO .......................................................................................................................................... 57
10.4 SEMODE ........................................................................................................................................... 57
10.5 SEREAD............................................................................................................................................ 58
10.6 SEWRITE .......................................................................................................................................... 58
10.7 SECFG .............................................................................................................................................. 59
10.8 SEPRG .............................................................................................................................................. 77
10.9 UPGFRM ........................................................................................................................................... 79
10.10 SEVER.......................................................................................................................................... 79
10.11 SECHKSUM .................................................................................................................................. 80
10.12 SEDUMP ....................................................................................................................................... 80
10.13 ASFCFG........................................................................................................................................ 80
10.14 MANCFG ...................................................................................................................................... 82
10.15 ASFMBOX .................................................................................................................................... 83
10.16 FLSHMODE .................................................................................................................................. 83
10.17 FLSHREAD ................................................................................................................................... 83
10.18 CHKPXE ....................................................................................................................................... 83
10.19 DIR .............................................................................................................................................. 84
10.20 ERASE.......................................................................................................................................... 84
10.21 PXEPRG ....................................................................................................................................... 84
10.22 FLSHDEV ..................................................................................................................................... 84
10.23 BITBANG ..................................................................................................................................... 84
10.24 SECLOCK ..................................................................................................................................... 85
10.25 SETORTURE ................................................................................................................................. 85
10.26 SEINIT.......................................................................................................................................... 85
10.27 SEARB ......................................................................................................................................... 85
10.28 SEPROTECT .................................................................................................................................. 86
10.29 SELCLOCK ................................................................................................................................... 86
10.30 SEMAP ......................................................................................................................................... 86
10.31 SETWOL ....................................................................................................................................... 86

page 4
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.32 SETPXE ........................................................................................................................................ 86


10.33 SETASF ........................................................................................................................................ 87
10.34 SECOMP ....................................................................................................................................... 87
10.35 DRESET........................................................................................................................................ 87
10.36 USERBLOCK ................................................................................................................................. 88
10.37 SETMBA ....................................................................................................................................... 88
10.38 SEGENCRC ................................................................................................................................... 88
10.39 SECFG1........................................................................................................................................ 88
10.40 SECFG2........................................................................................................................................ 89
10.41 SECFG3........................................................................................................................................ 89
10.42 SECFG4........................................................................................................................................ 90
10.43 SECFG5........................................................................................................................................ 91
10.44 SETIPMI ....................................................................................................................................... 91
10.45 LOADFW ...................................................................................................................................... 92
10.46 CPUDTT ....................................................................................................................................... 92
10.47 CPUDRT ....................................................................................................................................... 93
10.48 CPUTRACE ................................................................................................................................... 93
10.49 HALTCPU ..................................................................................................................................... 93
10.50 LOADBOOTCODE.......................................................................................................................... 94
10.51 DISASM........................................................................................................................................ 94
10.52 STEP ............................................................................................................................................ 94
10.53 GO ............................................................................................................................................... 94
10.54 SHOWGPR .................................................................................................................................... 95
10.55 PC ................................................................................................................................................ 95
10.56 BREAKPOINT ............................................................................................................................... 95
10.57 SELECT ........................................................................................................................................ 95
10.58 U ................................................................................................................................................. 95
10.59 TRAP ........................................................................................................................................... 95
10.60 CPUINFO ...................................................................................................................................... 96
10.61 CPUGPRSTATUS ........................................................................................................................... 96
10.62 CPUGPRRESTART ......................................................................................................................... 96
10.63 CPUFETCH ................................................................................................................................... 96
10.64 ROMCODETEST ............................................................................................................................ 96
10.65 APEINFO ...................................................................................................................................... 97
10.66 APECTL........................................................................................................................................ 97
10.67 APEPING ...................................................................................................................................... 98
10.68 APEREAD ..................................................................................................................................... 98
10.69 APEOTPKEY ................................................................................................................................. 98
10.70 APELOG ....................................................................................................................................... 98
10.71 DMAW ......................................................................................................................................... 99
10.72 DMAR ........................................................................................................................................ 100
10.73 DMA_H ...................................................................................................................................... 102
10.74 DMA_D ...................................................................................................................................... 102
10.75 DMA_ALLOC .............................................................................................................................. 102
10.76 MACLPK .................................................................................................................................... 102
10.77 BLAST........................................................................................................................................ 103
10.78 NICSTATS .................................................................................................................................. 105
10.79 RINGINDEX ................................................................................................................................ 107
10.80 PHYCTRL ................................................................................................................................... 108
10.81 TXPKT ....................................................................................................................................... 108
10.82 STATUSBLK ............................................................................................................................... 110
10.83 STSBLK ...................................................................................................................................... 110
10.84 TXCFG ....................................................................................................................................... 111
10.85 RXCFG ....................................................................................................................................... 112
10.86 TPROT........................................................................................................................................ 112

page 5
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.87 QSTAT ....................................................................................................................................... 112


10.88 DRVRCFG................................................................................................................................... 113
10.89 IRT ............................................................................................................................................ 113
10.90 MACMRD ................................................................................................................................... 113
10.91 MIIMRD ..................................................................................................................................... 114
10.92 PCIMRD ..................................................................................................................................... 114
10.93 INBAND ..................................................................................................................................... 114
10.94 MWRITE ..................................................................................................................................... 115
10.95 MREAD ...................................................................................................................................... 115
10.96 MDEV ........................................................................................................................................ 116
10.97 M2DEV ...................................................................................................................................... 116
10.98 MIIMODE ................................................................................................................................... 116
10.99 LBERTRAM ................................................................................................................................ 116
10.100 DBERTRAM ................................................................................................................................ 117
10.101 BERTSTATS ................................................................................................................................ 117
10.102 RM............................................................................................................................................. 117
10.103 MRLOOP .................................................................................................................................... 117
10.104 PHYMSE ..................................................................................................................................... 118
10.105 INITPHY ..................................................................................................................................... 118
10.106 TAPDUMP .................................................................................................................................. 118
10.107 MEMSEARCH ............................................................................................................................. 118
10.108 READ ......................................................................................................................................... 118
10.109 WRITE........................................................................................................................................ 119
10.110 POLL .......................................................................................................................................... 120
10.111 SETBIT ....................................................................................................................................... 121
10.112 CLEARBIT .................................................................................................................................. 122
10.113 READBIT .................................................................................................................................... 122
10.114 CREAD ....................................................................................................................................... 123
10.115 CWRITE ..................................................................................................................................... 123
10.116 PCIRD ........................................................................................................................................ 123
10.117 PCIWR........................................................................................................................................ 124
10.118 VPDTEST .................................................................................................................................... 124
10.119 REGTEST .................................................................................................................................... 124
10.120 MIITEST ..................................................................................................................................... 125
10.121 MSI ............................................................................................................................................ 125
10.122 MEMTEST .................................................................................................................................. 125
10.123 SETEST ...................................................................................................................................... 126
10.124 BIST ........................................................................................................................................... 126
10.125 NICTEST..................................................................................................................................... 126
10.126 INTRTEST................................................................................................................................... 127
10.127 PKTTEST .................................................................................................................................... 127
10.128 CPUTEST .................................................................................................................................... 127
10.129 DMATEST................................................................................................................................... 128
10.130 TESTE ........................................................................................................................................ 128
10.131 TESTD ........................................................................................................................................ 129
10.132 ASFTEST .................................................................................................................................... 129
10.133 BUSTEST .................................................................................................................................... 129
10.134 SRAMTEST ................................................................................................................................. 131
10.135 MSITEST .................................................................................................................................... 131
10.136 ROMTEST ................................................................................................................................... 131
10.137 GPIOTEST................................................................................................................................... 132
10.138 CPUDIAG ................................................................................................................................... 132
10.139 PCICFGTEST ............................................................................................................................... 132
10.140 PETEST ...................................................................................................................................... 133
10.141 ERRCTRL ................................................................................................................................... 133

page 6
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.142 SEDVT ....................................................................................................................................... 133


10.143 MIIMISCTEST ............................................................................................................................. 134
10.144 CPUGPRTEST .............................................................................................................................. 134
10.145 DMASHASTA .............................................................................................................................. 134
10.146 BINCHKSUM............................................................................................................................... 135
10.147 PMDCFG..................................................................................................................................... 135
10.148 PMPD ......................................................................................................................................... 135
10.149 INTR .......................................................................................................................................... 136
10.150 INTRCTRL .................................................................................................................................. 136
10.151 INTT .......................................................................................................................................... 136
10.152 MBUF......................................................................................................................................... 136
10.153 LOADDRV .................................................................................................................................. 137
10.154 UNLOADDRV ............................................................................................................................. 138
10.155 MACHALT .................................................................................................................................. 138
10.156 FTQ............................................................................................................................................ 138
10.157 ADDMC ...................................................................................................................................... 139
10.158 DELMC ...................................................................................................................................... 139
10.159 TXMACDES ................................................................................................................................ 139
10.160 TXMACSRC ................................................................................................................................ 139
10.161 CHKLDDRV ................................................................................................................................ 140
10.162 VLANTAG .................................................................................................................................. 140
10.163 REG ........................................................................................................................................... 140
10.164 EXIT .......................................................................................................................................... 140
10.165 DEBUG ....................................................................................................................................... 140
10.166 GPIOWRITE ................................................................................................................................ 141
10.167 GPIOREAD.................................................................................................................................. 141
10.168 PXECPY ..................................................................................................................................... 142
10.169 DEVICE ...................................................................................................................................... 142
10.170 VERSION .................................................................................................................................... 142
10.171 HELP .......................................................................................................................................... 142
10.172 ?................................................................................................................................................ 143
10.173 RADIX........................................................................................................................................ 143
10.174 NOLOG ...................................................................................................................................... 143
10.175 LOG ........................................................................................................................................... 143
10.176 PCIINIT ...................................................................................................................................... 143
10.177 PCISCAN .................................................................................................................................... 144
10.178 DOS ........................................................................................................................................... 144
10.179 SHELL ....................................................................................................................................... 144
10.180 DIAGCFG ................................................................................................................................... 144
10.181 RESET ........................................................................................................................................ 147
10.182 QUIT .......................................................................................................................................... 147
10.183 SMBUS ....................................................................................................................................... 147
10.184 CLS ............................................................................................................................................ 147
10.185 LOOP ......................................................................................................................................... 147
10.186 DBMODE .................................................................................................................................... 148
10.187 ASF ............................................................................................................................................ 148
10.188 NEW .......................................................................................................................................... 148
10.189 ASFPRG...................................................................................................................................... 148
10.190 SLEEP ........................................................................................................................................ 149
10.191 FILLPATTERN ............................................................................................................................. 149
10.192 INP ............................................................................................................................................ 149
10.193 OUTP ......................................................................................................................................... 149
10.194 SWITCH ..................................................................................................................................... 150
10.195 DO ............................................................................................................................................. 150
10.196 TXFILL ....................................................................................................................................... 150

page 7
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.197 WBUF ........................................................................................................................................ 151


10.198 RBUF ......................................................................................................................................... 151
10.199 CPBUF ....................................................................................................................................... 151
10.200 ECHO ......................................................................................................................................... 152
10.201 PAUSE........................................................................................................................................ 152
10.202 Q ............................................................................................................................................... 152
10.203 VERBOSE ................................................................................................................................... 152
10.204 BEEP .......................................................................................................................................... 153
10.205 VAR ........................................................................................................................................... 153
10.206 MEMINFO ................................................................................................................................... 153
10.207 DELVAR ..................................................................................................................................... 153
10.208 REGDUMP .................................................................................................................................. 153
10.209 REGCOMP .................................................................................................................................. 154
10.210 REGRESTORE ............................................................................................................................. 154
10.211 NVSIZE ...................................................................................................................................... 154
10.212 ASPM ......................................................................................................................................... 155
10.213 DIDS .......................................................................................................................................... 155
10.214 SERIAL ...................................................................................................................................... 156
10.215 POWER ...................................................................................................................................... 156
10.216 READBR ..................................................................................................................................... 156
10.217 WRITEBR ................................................................................................................................... 156
10.218 FINDBRIDGE .............................................................................................................................. 156
10.219 BRIDGE ...................................................................................................................................... 156
10.220 PERE .......................................................................................................................................... 157
10.221 PERD ......................................................................................................................................... 157
10.222 PECLR ........................................................................................................................................ 157
10.223 PECHK ....................................................................................................................................... 157
10.224 ISCSIPRG .................................................................................................................................... 157
10.225 UMPECHO .................................................................................................................................. 158
10.226 UMPCFG..................................................................................................................................... 158
10.227 SETIPMI ..................................................................................................................................... 159
10.228 SETUMP ..................................................................................................................................... 159
10.229 SEOTP ........................................................................................................................................ 159
10.230 OTPCHK ..................................................................................................................................... 160
10.231 DEFRAGMENT ............................................................................................................................ 160
10.232 SECFGSB1.................................................................................................................................. 160
10.233 SECFGSB2.................................................................................................................................. 161
10.234 SECFGSB3.................................................................................................................................. 162
10.235 SECFGHWSB1............................................................................................................................. 162
10.236 SECFGHWSB2............................................................................................................................. 163
10.237 SECFGHWSB3............................................................................................................................. 163
10.238 ESWITCH ................................................................................................................................... 164
10.239 SBFCFG ...................................................................................................................................... 164
10.240 LINKINTRTEST ........................................................................................................................... 164
10.241 IPV6EXTLD ................................................................................................................................ 164
10.242 IPV6EXTEN ................................................................................................................................ 165
10.243 CFGPAGESIZE ............................................................................................................................ 165
10.244 CPMU......................................................................................................................................... 165
10.245 MDIO ......................................................................................................................................... 165
10.246 WAIT ......................................................................................................................................... 166
10.247 IPSECSUPPORT ........................................................................................................................... 166
10.248 SADBTEST.................................................................................................................................. 166
10.249 SADBUTIL .................................................................................................................................. 166
10.250 APETEST .................................................................................................................................... 167

page 8
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

11 ERROR MESSAGES ..................................................................................................................... 168

page 9
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

page 10
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

1 Introduction
This program runs in two modes: Manufacturing mode and Engineering mode. The mode is
determined with the command line option or the configuration file. When the program is
running in manufacturing mode, it starts to run all tests in the configuration. If it detects an
error, it displays an error and exits the program. When the program is in engineering mode,
it prompts user to enter commands. The commands are explained in the later chapters. This
document provides the information on configuration file specification, command line
options and engineering diagnostic commands on Broadcom NetXtreme Ethernet adapter,
in particular to check out the functionality of the BCM5700 Family of Ethernet controllers
and its related components. In general, this program has a set of default configuration. It is
overwritten by configuration file. The command line option overwrites both default and the
configuration files.

page 11
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

2 Prerequisites
The engineering diagnostic is executed under DOS protected mode or under Unified
Extensible Firmware Interface (UEFI).

OS: Dos 6.22 or UEFI v2.0x or later

Software: [Link] for DOS and [Link], [Link] for UEFI (version 11.05
or later).

Input File List: The following files should be found in the same location of the b57diag.

[Link] (TX & RX CPUs Firmware file, xx chip type, yy version number)

[Link] (Serial EEPROM/FLASH config input file)

[Link], [Link], [Link], [Link] or [Link] (CPU Instruction test)

[Link] or [Link] (CPU Accessing test)

[Link], [Link] flashdg [Link], flashdg [Link], [Link], [Link]

[Link] or [Link]

[Link] (not required for UEFI)

[Link] (not required for UEFI)

Output File List:

The following file may be generated in run time depending execution option(s).

[Link]

page 12
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

3 Diagnostic Tests

The tests are divided into four groups: Register Tests, Memory Tests, Miscellaneous Tests, and
Data Tests. They numbered as group ‘A’, ‘B’, ‘C’, ‘D’, ‘E’, ‘F’, and ‘G’.

Note: For UEFI version, not all tests are supported. Refer to online help for more information.

3.1 Test Names


Group A.
A1. Indirect Register Test
A2. Control Register Test
A3. Interrupt Test
A4. BIST
A5. PCI Cfg Register Test
A6. Serial Number Reg Test
A5. Power Register Test
Groupt B.
B1. Scratch Pad Test
B2. BD SRAM Test
B3. DMA SRAM Test
B4. MBUF SRAM Test
B5. MBUF SRAM via DMA Test
B6. External SRAM Test
B7. CPU GPR SRAM Test
Group C.
C1. EEPROM Test
C2. CPU Test
C3. DMA Test
C4. MII Test
C5. VPD Test
C6. ASF Hardware Test
C7. ROM Expansion Test
C8. CPU Fetch Test
Group D.
D1. Mac Loopback Test
D2. Phy Loopback Test
D3. RJ45 Loopback Test
D4. 1G False Carrier Test
D5. MII Miscellaneous Test
D6. MSI Test
D7. E-Switch Test (5756 and 5761E devices only)
D8. SADB Test (available on NetXtreme Controllers with hardware IPSec support)
D9. IPsec Loopback Test (available on NetXtreme Controllers with hardware IPSec support)

page 13
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Group E.
E1. 1G Wire Open/Short (** ZERO LEN LB RJ45 **) Test

Group F. (valid on APE enabled NetXtreme Controllers only)


F1. Indirect APE Ctrl Register Test
F2. APE Control Register Test
F3. Indirect APE Peripheral Register Test
F4. APE Peripheral Register Test
F5. APE Scratch Pad Test
F6. APE Shared Memory Test
F7. APE Shared Memory Indirect Access Test
F8. APE Mutex Register Test
F9. APE Timers Test

Group G. (valid on APE enabled NetXtreme Controllers only)


G1. APE CPU Memory Test
G2. APE CPU Packet Test
G3. APE CPU SMBus Loopback Test
G4. APE CPU GPIO Register Test
G5. APE CPU Event Register Test
G6. APE CPU Mutex Register Test
G7. APE CPU Timers Test
G8. APE CPU GRC Reset Test
G9. APE USB Test (UEFI only)

3.2 Error Codes

The Error Codes are presented in Section 9 - ERROR MESSAGES.

3.3 Test Descriptions

3.3.1 A1. Indirect Register Test


Command: regtest -i

Function: Using indirect addressing method, writing increment data into MAC hash
Register table and read back for verification. The memory read/write is done 100 times
while increment test data.

Default: Enabled

3.3.2 A2. Control Register Test


Command: regtest

page 14
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Function: Each Register specified in the configuration contents is tested for read only bit
and read/write bit defines. The test writes zeroes and ones into the test bits to insure the
read only bits are not changed, and read/write bits are changed accordingly.

Default: Enabled.

3.3.3 A3. Interrupt Test


Command: intrtest

Function: This test verifies the interrupt functionality. It enables interrupt and waits for
interrupt to occur. It waits for 500ms and reports error if could not generate interrupts.

Default: Enabled

3.3.4 A4. BIST


Command: bist

Function: Hardware Built-In-Self-Test (BIST). This test initiates BIST, and wait for the
test result returned by hardware.

Default: Enabled

3.3.5 A5. PCI Cfg Register Test


Command: pcicfg

Function: This test verifies the access integrity of the PCI config registers.

Default: Enabled

3.3.6 A6. Serial Number Reg Test


Command: serial

Function: Tests the PCI-E Serial Number capabilities registers on chips that support the
Serial Number capability. This command is supported on 5751Cx, 5755, 5787.

Default: Enabled.

3.3.7 A7. Power Register Test


Command: power

Function: Tests the PCI-E Power capabilities registers on chips that support the Power
capability. This command is supported on 5751Cx, 5755, 5787.

Default: Enabled.

page 15
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

3.3.8 B1. Scratch Pad Test


Command: memtest -s

Function: This test tests the scratch pad SRAM on board. The following tests are
performed:

Data Pattern Test: Write test data into SRAM, read back to ensure data is correct. The test
data used is 0x00000000, 0xffffffff, 0xaa55aa55, and 0x55aa55aa.

Alternate Data Pattern Test: Write test data into SRAM. Write complement test data into
next address. Read back both data to insure the data is correct. After the test, the program
reads back data one more time to insure the data stays correct. The test data used is
0x00000000, 0xffffffff, 0xaa55aa55, and 0x55aa55aa.

Address Test: Write each address with unique increment data. Read back data to insure
data is correct. After fill the entire data with the unique data, the program reads back data
again to insure data stays the same.

Walking Bit Test: For each address location, starting at bit 0, each bit is set, tested and
then shifted left by one. This process is repeated for each of the 32 bits in each address
location in the entire memory test range.

Pseudo Random Data Test: A pre-calculated pseudo random data is used to write a
unique data into each test RAM. After the first pass the test, the program reads back one
more time to insure data stays correct.

Default: Enabled

3.3.9 B2. BD SRAM Test


Command: memtest -b

Function: This test tests the BD SRAM. This performs exact the same way of testing as
described in B1, the Scratch Pad Test.

Default: Enabled

3.3.10 B3. DMA SRAM Test


Command: memtest -d

Function: It tests DMA SRAM by performing the tests described in test B1, the Scratch
Pad Test.

Default: Enabled

page 16
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

3.3.11 B4. MBUF SRAM Test


Command: memtest -m

Function: It tests MBUF SRAM by performing the tests described in test B1, the Scratch
Pad Test.

Default: Enabled

3.3.12 B5. MBUF SRAM via DMA Test


Command: memtest -x

Function: Eight test pattern data are used in the test. They are described below. A 0x1000
sized data buffer is used for this test. Before each pattern test, the buffer is initialized and
filled with the test pattern. It then, performs size 0x1000 transmit DMA from host buffer to
NIC MBUF memory. Verify the data integrity in MBUF against host memory and repeat
the DMA for the entire MBUF buffer. Then it performs receive DMA from NIC to host.
The 0x1000-byte test buffer is cleared to zero before each receive-DMA. Verify the data
integrity and test is repeated for the entire MBUF SRAM range.

Test Pattern Description


“16 00's 16 FF's” Full the entire host DMA buffer with 16 bytes of 00’s and then 16
bytes of FF’s.
“16 FF's 16 0's” Full the entire host DMA buffer with 16 bytes of 00’s and then 16
bytes of FF’s.
“32 00's 32 FF's” Full the entire host DMA buffer with 32 bytes of 00’s and then 32
bytes of FF’s.
“32 FF's 32 00's” Full the entire host DMA buffer with 32 bytes of FF’s and then 32
bytes of 00’s.
“00000000's” Full the entire host DMA buffer with all zeros.
“FFFFFFFF's” Full the entire host DMA buffer with all FF’s.
“AA55AA55's” Full the entire host DMA buffer with data 0xAA55AA55.
“55AA55AA's” Full the entire host DMA buffer with data 0xAA55AA55.
Default: Enabled

3.3.13 B6. External SRAM Test


Command: memtest -e

Function: It tests external SRAM by performing the tests described in test B1, the Scratch
Pad Test.

Default: Disabled

3.3.14 B7. CPU GPR Test


Command: memtest -b

page 17
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Function: This test tests the CPU General Purpose Registers. This performs exact the same
way of testing as described in B1 over 3 voltages (1.1V, 1.2V, 1.3V).

Default: Enable

3.3.15 C1. EEPROM Test


Command: setest

Function: An increment test data is used in EEPROM test. It fills the test data into the test
range and read back to verity the content. After the test, it fills data with zero to clear the
memory.

Default: Enabled

3.3.16 C2. CPU Test


Command: cputest

Function: This test opens the file [Link]. If file exists and content is good, it loads code to
rx and tx CPU and verifies CPU execution.

Default: Enabled

3.3.17 C3. DMA Test


Command: dmatest

Function: Both high and low priorities DMA are tested. It moves data from host memory
to NIC SRAM, verifies data, and then moves data back to host memory again to verify
data.

Default: Enabled

3.3.18 C4. MII Test


Command: miitest

Function: The function is identical to A2. Control Register Test. Each Register specified in
the configuration contents read only bit and read/write bit defines. The test writing zero and
one into the test bits to insure the read only bits value are not changed, and read/write bits
are changed accordingly.

Default: Enabled.

Default Register table

The test will try to read the register configuration file ‘[Link]’ for the register defines. If
the file does not exists, the following table is used:

page 18
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Offset R/O Mask R/W Mask


0x00 0x0000 0x7180
0x02 0xffff 0x0000
0x03 0xffff 0x0000
0x04 0x0000 0xffff
0x05 0xefff 0x0000
0x06 0x0001 0x0000
0x07 0x0800 0xb7ff
0x08 0xffff 0x0000
0x09 0x0000 0xff00
0x0a 0x7c00 0x0000
0x10 0x0000 0xffbf
0x11 0x3300 0x0000
0x19 0x001f 0x0000
0x1e 0x0000 0xffff
0x1f 0x0000 0xffff

3.3.19 C5. VPD Test


Command: vpdtest

Function: It saves the content of VPD first before perform the test. Once it is done, it
writes one of the five pattern test data, 0xff, 0xaa, 0x55, increment data, or decrement data,
into VPD memory. By default, increment data pattern is used. It writes and reads back the
data for the entire test range, and then restores the original content.

Default: Enabled

3.3.20 C6. ASF Test


Command: asftest

Function:
1. Reset test.
Setting reset bit, poll for self-clearing. Verify reset value of registers.
2. Event Mapping Test
Setting SMB_ATTN bit. By changing ASF_ATTN LOC bits, verify the mapping bits
in TX_CPU or RX_CPU event bits.
3. Counter Test
Clear WG_TO, HB_TO, PA_TO, PL_TO, RT_TO bits by setting those bits. Make sure
the bits clear.
Clear Timestamp Counter. Writing a value 1 into each PL, PA, HB, WG, RT counters.
Set TSC_EN bit.

page 19
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Poll each PA_TO bit and count up to 50 times. Check if PL_TO gets set at the end of
50 times. Continue to count up to 200 times. Check if all other TO bits are set and
verify Timestamp Counter is incremented.
Default: Enabled

3.3.21 C7. Expansion ROM Test

Command: romtest

Function: This function tests the ability to enable/disable/access the expansion


rom on the device.
Default: Enabled

3.3.22 C8. CPU Fetch Test

Command: cpufetch

Function: Test the CPU instruction-fetch logic a 100 times on 5705 and later devices. The
voltage is also varied to 1.1V and 1.3V on devices that support voltage variation.
Default: Enabled

3.3.23 D1. Mac Loopback Test


Command: pkttest -m

Function: This is internal loopback data transmit/receive test. It initializes MAC into
internal loopback mode, and transmits 200 packets. The data should be routed back to
receive channel and receive by the receive routine, which verifies the integrity of data. One
Giga bit rate is used for this test.

Default: Enabled

3.3.24 D2. Phy Loopback Test


Command: pkttest -p

Function: This test is same as D1. Mac Loopback Test except, the data is routed back via
physical layer device. One Giga bit rate is used for this test.

Please note if the device supports E-Switch, such as 5756, the test is performed on both
laptop mode and docking mode. To perform the test only on the default port, two method
can be used: 1. command line option ‘-disableeswitch’; 2. ‘eswitch –f’ in engineering
mode before the test.

Default: Enabled

page 20
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

3.3.25 D3. RJ45 Loopback Test


Command: pkttest -e

Function: This is external loopback test. From the UUT point of view, no loopback mode
is configured. The data expected to be routed back by RJ45 loopback connector. 10M/s,
100M/s, and 1000M/s are used for this test.

Please note if the device supports E-Switch, such as 5756, the test is performed on both
laptop mode and docking mode. To perform the test only on the default port, two method
can be used: 1. command line option ‘-disableeswitch’; 2. ‘eswitch –f’ in engineering
mode before the test.

Default: Disabled

3.3.26 D4. 1G False Carrier Test


Command: nictest d4

Function: This test executes the same procedure as test D3 and tests to see if a false carrier
was detected at the end of the test. The –l200, –dispgbpkt, -disppkt and –errlimit command
line options were added to configure a number of operational parameters. The details of the
command line options are provided in the “COMMAND LINE OPTION PARAMETERS”
section.

Please note if the device supports E-Switch, such as 5756, the test is performed on both
laptop mode and docking mode. To perform the test only on the default port, two method
can be used: 1. command line option ‘-disableeswitch’; 2. ‘eswitch –f’ in engineering
mode before the test.

Default: Disabled

3.3.27 D5. MII Miscellaneous Test


Command: nictest d5

Function: This function tests the auto-polling and phy-interrupt capabilities. These are the
functionalities of the phy.

Default: Enabled

3.3.28 D6. MSI Test


Command: msitest

Function: Testing Message Signaled Interrupt Function to see if it handles this interrupt
correctly.

Default: Enabled

page 21
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

3.3.29 D7. E-Switch Test


Command: nictest d7

Function: This function tests the E-Switch Ethernet porting switching hardware.

Default: Enabled (available only for NetXtreme controllers with E-Switch support)

3.3.31 D8. SADB Test


Command: nictest d8

Function: This function tests the Security Association Data Base hardware in IPsec
supported NetXtreme Ethernet controllers.

Default: Enabled (available only on NetXtreme controllers with IPSec support)

3.3.32 D9. IPsec Loopback Test


Command: nictest d9

Function: An external loopback test is performed at 10/100/1000 Mbits/s using IPsec


encrypted packets. Various hardware supported encryption ciphers are used to encrypt and
decrypt packets and verify the proper operation of the IPsec hardware.

A zero length loopback connector is placed at the RJ45 connector of the LOM/NIC. After
running the loopback test at 1000 Mbits/s the line signal quality is tested order to catch line
faults (shorts or opens). This test is used during manufacturing in order to detect
board/system build issues on the line/analog side of the Ethernet controller.

Default: Disabled (available only on NetXtreme controllers with IPSec support)

3.3.33 E1. 1G Wire Open/Short (** ZERO LEN LB RJ45 **) Test
Command: nictest e1

Function: An external loopback test is performed at 10/100/1000 Mbits/s. A zero length


loopback connector is placed at the RJ45 connector of the LOM/NIC. After running the
loopback test at 1000 Mbits/s the line signal quality is tested order to catch line faults
(shorts or opens). This test is used during manufacturing in order to detect board/system
build issues on the line/analog side of the Ethernet controller.

Default: Disabled

page 22
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

NOTE: The following tests in test groups F and G are only enabled for NetXtreme Ethernet
Controllers which support the Application Processing Engine (APE).

3.3.34 F1. Indirect APE Ctrl Register Test


Command: nictest f1

Function: Using indirect addressing method, incremented data is written into APE control
registers and read back for verification. The memory read/write is done 100 times while
incrementing test data.

Default: Disabled

3.3.35 F2. APE Control Register Test


Command: nictest f2

Function: Each Register specified in the APE control register block is tested for read only
bits and read/write bits. The test writes zeroes and ones into the test bits to insure the read
only bits are not changed, and read/write bits are changed accordingly.

Default: Disabled

3.3.32 F3. Indirect APE Peripheral Register Test


Command: nictest f3

Function: Using indirect addressing method, incremented data is written into APE
Peripheral registers and read back for verification. The memory read/write is done 100
times while incrementing test data.

Default: Enabled

3.3.33 F4. APE Peripheral Register Test


Command: nictest f4

Function: Each Register specified in the APE Peripheral register block is tested for read
only bits and read/write bits. The test writes zeroes and ones into the test bits to insure the
read only bits are not changed, and read/write bits are changed accordingly.

Default: Enabled

3.3.34 F5. APE Scratch Pad Test


Command: nictest f5

page 23
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Function: This test tests the APE scratch pad SRAM on the APE enabled NetXtreme
controllers. The following tests are performed:

Data Pattern Test: Write test data into SRAM, read back to ensure data is correct. The test
data used is 0x00000000, 0xffffffff, 0xaa55aa55, and 0x55aa55aa.

Alternate Data Pattern Test: Write test data into SRAM. Write complement test data into
next address. Read back both data to insure the data is correct. After the test, the program
reads back data one more time to insure the data stays correct. The test data used is
0x00000000, 0xffffffff, 0xaa55aa55, and 0x55aa55aa.

Address Test: Write each address with unique increment data. Read back data to insure
data is correct. After filling the entire memory length with the unique data, the program
reads back the data again to insure data stays the same.

Walking Bit Test: For each address location, starting at bit 0, each bit is set, tested and
then shifted left by one. This process is repeated for each of the 32 bits in each address
location in the entire memory test range.

Pseudo Random Data Test: A pre-calculated pseudo random data is used to write a
unique data into each test RAM. After the first pass the test, the program reads back one
more time to insure data stays correct.

Default: Enabled

3.3.35 F6. APE Shared Memory Test


Command: nictest f6

Function: Performs memory data verification tests on the APE Shared Memory. This test
uses the same the method of testing as described in F5. APE Scratch Pad Test.

Default: Enabled

3.3.36 F7. APE Shared Memory Indirect Access Test


Command: nictest f7

Function: Performs memory data verification tests using Indirect Addressing Method, on
the APE Shared Memory. This test uses the same the method of testing as described in F5.
APE Scratch Pad Test.

Default: Enabled

3.3.37 F8. APE Mutex Register Test


Command: nictest f8

page 24
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Function: Each of the registers in the APE Mutex Register block is tested to verify that
each bit set in the Mutex Request register can acquire a corresponding grant bit in its paired
Mutex Grant register. After each grant bit is set it is written with back to verify the grant
bit can be cleared.

Default: Disabled

3.3.38 F9. APE Timers Test


Command: nictest f9

Function: This test each of the APE internal timer registers from the host interface. The
test verifies that the APE timers are functioning and within acceptable tolerances.

Default: Disabled

3.3.39 G1. APE CPU Memory Test


Command: nictest g1

Function: This test executes a series of memory tests using the APE CPU.

Data Pattern Test: Write test data into SRAM, read back to ensure data is correct. The test
data used is 0x00000000, 0xffffffff, 0xaa55aa55, and 0x55aa55aa.

Alternate Data Pattern Test: Write test data into SRAM. Write complement test data into
next address. Read back both data to insure the data is correct. After the test, the program
reads back data one more time to insure the data stays correct. The test data used is
0x00000000, 0xffffffff, 0xaa55aa55, and 0x55aa55aa.

Address Test: Write each address with unique increment data. Read back data to insure
data is correct. After fill the entire data with the unique data, the program reads back data
again to insure data stays the same.

WalkingOne bit Test: For each address. Data one is written and read back for testing.
Then shift the data left one bit, so the data becomes two and do the same test again. It
repeats for 32 times until the test bit is shifted out of test data. The same is test is repeated
for entire test range.

Pseudo Random Data Test: A pre-calculated pseudo random data is used to write a
unique data into each test RAM. After the first pass the test, the program reads back one
more time to insure data stays correct.

Default: Enabled

3.3.40 G2. APE CPU Packet Test


Command: nictest g2

page 25
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Function: An Ethernet packet is transmitted via internal loopback from the APE CPU and
verified for data integrity and that packet interrupts are generated.

Default: Enabled

3.3.41 G3. APE CPU SMBus Loopback Test


Command: nictest g3

Function: This test sends and receives SMBus messages from the APE CPU via loopback
on the SMBus controllers and verifies that correct data was received. (Requires loopback
jumpers to be installed).

Default: Disabled

3.3.42 G4. APE CPU GPIO Register Test


Command: nictest g4

Function: This test writes zeroes and ones to the GPIO output pins via the APE CPU to
insure the bits are changed accordingly and that GPIO state change interrupts are generated.

Default: Disabled

3.3.43 G5. APE CPU Event Register Test


Command: nictest g5

Function: In this test the APE CPU writes to the APE event registers to verify that each
event state can generate a corresponding interrupt.

Default: Enabled

3.3.44 G6. APE CPU Mutex Register Test


Command: nictest g6

Function: Each of the registers in the APE Mutex Register block is tested from the APE
CPU. This test verifies that each bit set in the Mutex Request register can acquire a
corresponding grant bit in its paired Mutex Grant register. After each grant bit is set it is
written with back to verify the grant bit can be cleared.

Default: Enabled

3.3.45 G7. APE CPU Timers Test


Command: nictest g7

page 26
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Function: This test each of the APE internal timer registers using the APE CPU. The test
verifies that the timers are functioning and within acceptable tolerances.

Default: Enabled

3.3.46 G8. APE CPU GRC Reset Test


Command: nictest g8

Function: This test verifies that the GRC port interrupt function can be detected via the
APE CPU.

Default: Enabled

3.3.47 G9. APE USB Test (UEFI only)


Command: nictest g9

Function: This test verifies that the APE USB port can be detected from the host
controller by executing a series USB descriptor query commands. This test is only
available on the UEFI version of B57diag.

Default: Disabled

page 27
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

4 Command line option parameters

When users invoke this program, a set of option parameter can be used to overwrite the
configuration file or the default configuration. This section summarizes the options. The options are
case sensitive.
-putil Call “[Link]” utility to unload PXE driver.

When "-putil" was entered, diag will call another application "[Link]".
"[Link]" will unload PXE and such that diag can have full control over the device.
This option switch should be used when updating firmware with "-firmall" option switch
via PXE connection.

-seldev <VID_DID> option to select devices that match VID and DID

Use this option to select target devices. Other devices, which have different VIDs and
DIDs, will not be selected and listed. This option switch can be used along with “-firm”
and “-firmall” option switches.

Example: a:\b57diag –b57eng –seldev 14e411677

-uump <filename> used for field program of UMP firmware

The feature is used to execute a field upgrade of UMP firmware. The firmware is
programmed into a/the device/s specified by “-c” option switch if UMP firmware is
originally loaded in NVRAM

-dir used for displaying file directory in NVRAM

The feature is used to display file directory in NVRAM. The file directory in the
NVRAM of device/s specified by"-c" option switch will be display. If no "-c"
option switch has been entered, the file directory of all detected devices will be
displayed. In order to log the file directory to a log file, "-l" option switch option
must be entered BEFORE "-dir" option switch. Since this is a single function
command, the will be no "nictest" or other functions will be preformed.

-pump <file> Program UMP firmware


This option needs to follow the –e and –c options. If this option is entered, the program will
retrieve the UMP firmware filename from the command line then it will start programming.
Example:
b57diag –e <code> -c 0 –pump ee5714c1.00
-pump1 <file> Program UMP firmware only
The feature is used to execute a field upgrade of NVRAM to add UMP firmware. The
firmware is programmed into a/the device/s specified by “-c” option switch.
-u <value> : Enable/Disable (value = 1/0) UMP in manufacture mode

page 28
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-piscsi <file> Program ISCSI firmware


This option needs to follow the –e and –c options. If this option is entered, the program will
retrieve the ISCSI firmware filename from the command line then it will start
programming.
Example:
b57diag –e <code> -c 0 –piscsi [Link]
-piscsicfg Force program ISCSI CFG firmware
If this option is entered, it will force program the ISCSI CFG firmware to NVRAM. This
option must be used along with –piscsi option.
Example:
b57diag -e <code> -c 0 –piscsi [Link] -piscsicfg
-piscsiprg Force program ISCSI PRG firmware
If this option is entered, it will force program the ISCSI PRG firmware to NVRAM. This
option must be used along with –piscsi option.
Example:
b57diag -e <code> -c 0 –piscsi [Link] -piscsiprg

-piscsi1 <filename> used for field program of ISCSI firmware

The feature is used to execute a field upgrade of NVRAM to add ISCSI firmware. The
firmware is programmed into a/the device/s specified by “-c” option switch.

-smbaddr <hex1> | <hex2> | …….| <hexn> used for programming SMBus Address for
ASF/IPMI firmware.

The feature will allow user to program SMBus Address for ASF/IPMI firmware. This
switch can take multiple parameters in HEX.
Example
1. -smbaddr A4 (SMB Address = 0xA4)
2. -smbaddr A4 A6 (SMB Address for 1st device=0xA4 and 2nd device = 0xA6)

This switch must be used along with -c option to indicate the target device.
Example:
b57diag -c 0 3 6 -smbaddr A4 A6 A8 -t abcd.
b57diag –c 0 –e b57kia –pasf [Link] –smbaddr A4 –t abcd

-chksecfg <file_p> | <file_s> will enable the NVRAM SecfgTest


Boot code configuration will be checked against input files. The input files are in the
same format as [Link]. <file_p> is for the primary port and <file_s> is for the

page 29
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

secondary port. Software will read command from input files and compare with the
boot code configuration and return “Passed” or “Failed” accordingly.
Example:
b57diag –chksecfg file_p.txt (for single port devices)
b57diag –chksecfg file_p.txt file_s.txt (for dual port devices)

-nosz disable storing NVRAM and TPM size in NVRAM

Disable the storing of the TPM and NVRAM size in NVRAM when diagnostics is run from
the command prompt. Use the "-nosz" option when repeatedly power cycling a system in
order not to exhaust the total NVRAM write cycles.
-smbaddr <hex1> | <hex2>…|<hex3> Configure ASF SMBus Addresses.
The option will configure the ASF SMBus Address field in ASF Configuration
block.
The option can take multiple parameters in HEX.
Example:
a. -smbaddr 45 (SMB Address = 0x45)
b. -smbaddr 45 6c (SMB Address for 1st device=0x45 and 2nd device = 0x6c)

This option must be used along with -c option. Number of parameters for -
smbaddr must be the same as number of devices selected by -c.

Example:
b57diag -c 0 3 6 -smbaddr 6c-6e -t abcd.
b57diag –c 0 –e b57kia –pasf [Link] –smbaddr 66 –t abcd

-mfct <filename> updates the PCI SSID and SVID

Use this option to modify the PCI SSID and SVID stored in NVRAM. The new SSID and
SVID are specified in the file <filename>. The format of <filename> is specified in the
“[Link] format” section below.

-sil suppresses warning messages of the “-firm” and “-firmall” commands

The warning message, “Boot code file and device type incompatible produced by the “-
firm” and “–firmall” commands is not displayed when the “-sil” command line parameter is
entered before the “-firm” and “–firmall” commands. The “-firm” and “-firmall” commands
are described below.

-rf <x> selects a reference device to use during external loopback

page 30
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Use this option with the external loopback test D3 to select a reference card. During the
external loopback test the physical loopback can be provided with a RJ45 loopback plug or
a CAT5 cable connected to a reference device (which loops back the data).

-lbe g:h:t define the number of packets to use during external loopback

Selects the number of packets to send during the external loopback test D3 (g ,h ,t are the
gigabit, hundred megabit, and ten megabit packet counts respectively) (default values are
g=2000, h=1000, t=600). It is mandatory that all packets counts are entered with this
command line option.

-ckdev <xy> executes diagnostic only x=chip rev and y=metal rev

If <xy> does not match the device being accessed diagnostics will not execute. Use this
option on a production line to verify that only chips of a specific rev are run with
diagnostics and all others fail.

-l200 <m200> controls the number of 200 packets to send

This option is used for the D4, “1G False Carrier loopback test. During the test packets are
sent out in groups of 200. The user specified <m200> value determines the number of 200
packet groups to send out. The default value is <m200> =50 or 50 groups of 200 packets.

-disppkts display the packet count during the progress of the test

This option is used for the D4, “1G False Carrier loopback test. On long-term test this
option is entered to display the packet count every 20,000 packets to let a user know the
test is operating normally and not frozen.

-dispgbend display the packet count at the end of the test

This option is used for the D4, “1G False Carrier loopback test. This option is entered to
print out the final packet count at the end of the test.

-errlimit <lim> controls the number of errors seen before the test fails

This option is used for the D4, “1G False Carrier loopback test. The default value is <lim>
=3.

-pktf0 packet data pattern is alternating 64 1’s and 0’s

This option is used for the D4, “1G False Carrier loopback test. The default packet data is
an incrementing value per byte. With this option the packet data alternate between 64 1’s
and 0’s that are aligned on a 64-bit PCI bus for maximum transitions.

-dids display chip information such as the PCI DID and VID

page 31
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

The feature outputs the following information: PCI DID, VID, SDID & SVID; MAC
address, Firmware revision, PXE, PXESpd, WOL, ASF, MBA, Bond Rev. This
information can be used to verify the setup of a chip after a firmware upgrade.

-elog <filename> an error log file <filename> used to log diagnostics failures

The feature is used to log the failure information of the diagnostics run. When an error
occurs if the file <filename> exists it is appended to and if it does not exist it is created. If
there are no diagnostics failures then the file in not appended or created. A user abort of the
diagnostics testing is log to the error log file <filename>.

-firm <filename> used for field upgrade of bootcode firmware

The feature is used to execute a field upgrade of bootcode firmware. The bootcode
firmware is programmed into a/the device/s of a system if there is a match of the PCI DID,
VID, SDID & SVID of firmware and device. For legacy bootcode, only VPD data block
and Phase 1 and Phase 2 bootcode will be updated by default. For Selfboot firmware and
Hardware Selfboot firmware, only patches will be updated.

-firmall <filename> used for field upgrade for entire NVRAM image

The feature is used to execute a field upgrade of entire NVRAM image. The new NVRAM
image is programmed into a/the device/s of a system if there is a match of the PCI DID,
VID, SDID & SVID of firmware and device. Media Manufact Region and Media VPD
Block in NVRAM will be preserved. If the Advance Firmware, such as ASF and IPMI, is
present, the Configuration Block of the firmware will also be preserved. Three addition
command line parameters, “-updateasfcfg “-updatesecfg “-updateiscsicfg” and “-sil can be
used along with “-firmall” command.

-updateasfcfg update the advance firmware configuration block of NVRAM with that of
the NVRAM image provided by “-firmall” command

When “-updateasfcfg” command line parameter is entered before “-firmall” command, the
Advance Firmware Configuration Block of the NVRAM will not be preserved. It will get
updated by the input file of “-firmall” command. The “-firmall” command is described
above.

-updatesecfg update the Media Manufact Region and Media VPD Block, of NVRAM
with that of the NVRAM image provided by “-firmall” command

When “-updatesecfg” command line parameter is entered before “-firmall” command, the
Meida Manufact Region and Media VPD Block of the NVRAM will not be preserved.
They will get updated by the input file of “-firmall” command. The “-firmall” command is
described above.

-updateiscsicfg update the ISCSI firmware configuration block of NVRAM with that of
the NVRAM image provided by “-firmall” command

page 32
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

When “-updateiscsicfg” command line parameter is entered before “-firmall” command, the
ISCSI Firmware Configuration Block of the NVRAM will not be preserved. It will get
updated by the input file of “-firmall” command. The “-firmall” command is described
above.

-pipmi <filename> used for field program of IPMI firmware

The feature is used to execute a field upgrade of NVRAM to add IPMI firmware. The
firmware is programmed into a/the device/s specified by “-c” option switch.

-uipmi <filename> used for field program of IPMI firmware

The feature is used to execute a field upgrade of IPMI firmware. The firmware is
programmed into a/the device/s specified by “-c” option switch if IPMI firmware is
originally loaded in NVRAM

-lbspd <spd> selects the line speeds to run test D3 (external loopback)

The external loopback test, by default, runs lines speeds of 10/100/1000 Mbits/s. The user
can select to run any combination of the line speeds to run the external loopback via this
option. The <spd> parameter specifies the operational speed by using t/h/g for 10/100/1000
Mbits/s respectively. To run test D3 at a 100 Mbits/s line rate the user would enter
“b57diag –t abcd –T d3 –lbspd h”. To run test D3 at a 100 Mbits/s and 1 Gbit/s the user
would enter “b57diag –t abcd –T d3 –lbspd hg”.

-hlb <spd> puts the UUT into the host loopback mode

All data sent to the device on the line side will be looped back to the line. This setup can be
used to test a specific device with an external tester or can be used with the –tr option to
perform a requestor-response test. The optional <spd> parameter specifies the operational
speed by using 10/100/1000 for 10/100/1000 Mbits/s respectively. The default value is
1000 Mbits/s.

-tr <pkts> <spd> the UUT transmits and receives data

The UUT will transmit the number of packets specified by <pkts>. The default number of
packets transmitted is 1,000,000. The UUT will receive all packets sent to it via the line
side. Counts of the transmitted and received packets will be presented to the user. This
setup can be used to test a specific device with an external tester or can be used with the –
hlb option to perform a requestor-response test. The optional <spd> parameter specifies the
operational speed by using 10/100/1000 for 10/100/1000 Mbits/s respectively. The default
value is 1000 Mbits/s.

-c <num> specify UUT device number

When more than one device is in the system, the devices are number starting from zero. For
example, if there is three devices detected, the device is numbered as 0,1,and 2. In this case,
by entered the parameter –c 2 will select the last found device as default UUT.

page 33
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

In manufacture testing mode, by default, all devices are tested; however, if this option is
used, only that selected device is tested.

Example: -c 2

-l <filename> log file

All diagnostic output can be saved in a log file. Type log file name is specified by this
option. The default is no log file.

Example: -l [Link]

-w <value> enable WOL programming in manufacture mode

After a successful manufacturing testing, the program will program WOL to either enable
or disable mode (<value> = 1/0). By default, the WOL is programmed as disable. Entering
value=1 will enable WOL.

When –f is entered, software uses [Link]’s content for WOL setting.

When –w 1 is entered with –f, software forces WOL enabled.

-x <value> enable PXE in manufacture mode

After a successful manufacturing testing, the program will program PXE to either enable or
disable mode (<value> = 1/0). By default, the PXE is programmed as disable. Entering
value=1 will enable PXE.

When –f is entered, software uses [Link]’s content for PXE setting.

When –x 1 is entered with –f, software forces PXE enabled.

-t <id> disable test


-T <id> enable test
A certain test is enabled or disabled by default. User can overwrite the enabling status by
those options. The test id must start with a letter ‘A’, ‘B’, ‘C’, or ‘D’ to indication the
group and followed by test numbers. Each digit of number represents the sub-test number.
For example, if the user wants to disable test A1 and A3. The option –t A13 should be
entered. If no test numbers entered, all tests in that group are selected. For the tests not
specified, the default setting will be used. To enable or disable all tests, use the wildcard
character “*” by itself.

Example: -t A15BC1 -T C4 –t D2
This disables A1, A5, B1, B2, B3, B4, B5, B6, C1, D2 and enables C4
Example: -t * -T d3
This disables all tests, then enables just the D3 test.

page 34
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Default Settings:

Enabled Tests:
A1. Indirect Register Test
A2. Control Register Test
A3. Interrupt Test
A4. Built In Self Test
A5. PCI Cfg Register Test
B1. Scratch Pad Test
B2. BD SRAM Test
B3. DMA SRAM Test
B4. MBUF SRAM Test
B5. MBUF SRAM via DMA Test
C1. NVRAM Test
C2. CPU Test
C3. DMA Test
C4. MII Test
C5. VPD Test
C6. ASF Hardware Test
C7. ROM Expansion Test
C8. CPU Fetch Test
D1. Mac Loopback Test (not enabled on BCM5761)
D2. Phy Loopback Test
D5. MII Miscellaneous Test
D6. MSI Test
D7. E-Switch Test
Disabled Tests:
B6. External SRAM Test
D3. RJ45 Loopback Test
D4. 1G False Carrier Test

For BCM5761 devices the following tests are available:


Enabled Tests:
D8. SADB Test
F3. Indirect APE Peripheral Register Test
F4. APE Peripheral Register Test
F5. APE Scratchpad Memory Test
F6. APE Shared Memory
F7. APE Shared Mem Indirect Access Test
G1. APE CPU Memory Test
G2. APE CPU Packet Test
G5. APE CPU Event Register Test
G6. APE CPU Mutex Register Test
G8. APE CPU GRC Reset Test

page 35
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Disabled Tests:
D9. IPSec Loopback Test
F1. Indirect APE Ctrl Register Test
F2. APE Control Register Test
F8. APE Mutex Register Test
F9. APE Timers Test
G3. APE CPU SMBus Loopback Test
G4. APE CPU GPIO Register Test
G9. APE USB Test (UEFI Only)

-I <num> iteration number

Use this option to specify the number of times the tests to be run. The default is run one
time. A number zero indicates loop forever. A control-C or control-break key can be used
to break the loop. Any error detected will also stop testing after reporting the error.

Example: -I 5
Run tests five times.

-ver display current version number


If this option is entered, it displays the software version number/silkscreen revision and
then exits the program.

-e <code> Encryption Code


This option is required to use option -geneep, –f, -m, –n, -mac and -s.

-geneep <file> Generate [Link] file from [Link]


A password is needed to run this option. With this option, it updates the specified eeprom
binary file with the specifications defined in [Link]. Please see Section 6.0
[Link] format for detailed argument description.

-bus <bus:dev:func> Test UUT location


If only bus number has been specified, the program will test all the UUTs at the
specified bus number.
Example: -bus 2.
If bus number and device number have been specified, the program will test all the
UUTs with the specified bus number and device number.
Example: -bus 2:4

page 36
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

If bus number, device number and function number have been specified, the
program will only test the UUT with the specified bus number, device number and
function number.
Example: -bus [Link]
This option should NOT be used along with –c option.

-dpmi Use DPMI memory allocation


Use DPMI memory allocation method to allocate memory instead of malloc() or free()

-f <filename> Program [Link]


The program programs the content of the specified file into EEPROM before testing.

-m Program MAC address


If this option is entered, the program will prompt user for a new MAC address to be
enter/scan before testing starts.

-mac <mac address> Program MAC address from command line


If this option is entered, the program will retrieve MAC address right after the –mac option
is entered. The mac address has to be entered in hex and as shown in the following
example:
b57diag –mac 001018010203

-fmac <filename> Program MAC address from a file


If this option is entered, the program will retrieve MAC address from the specified file
before starts testing. If the test passes, the MAC address from the specified file will be
incremented; if not, it will stay unchanged. The text file which contains the MAC address
range has the following format and the numbers are in hexadecimal:
mac_addr_pref = xxxxxx => Which is the prefix of the MAC address.
mac_addr_start = xxxxxx => Which is the start of the address range.
mac_addr_end = xxxxxx => Which is the end of the address range.
Example:
mac_addr_pref = 001018
mac_addr_start = 000100
mac_addr_end = 000FFF
Working in conjunction with –f <file> option, this –fmac option is equivalent to option –m.

page 37
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-n Run program in Manufacturing Loop mode.


With this option, the –I, iteration number option, is ignored. The program will run in
manufacturing loop mode. Power on/off is supported. After each test, the program will
prompt user to exchange the UUT before starts another testing.

-s Skip eeprom programming process.


With this option, the program will skip the eeprom programming process. However, it will
check for the eeprom content and print a warning message if the content is not valid.

The -m and -f combination will create the following behavior:

With both -f and -m:

Program will not validate the eeprom content and go ahead to prompt user for the MAC address. It
programs MAC address and EEPROM content and then checks the validity of eeprom content at the end of
programming.

Loading EEPROM content from [Link]: passed


Programming EEPROM from [Link]....: passed
Checking EEPROM content...............: passed

-f only:

Program will check the validity of eeprom. If it is not valid, it will act as a), -f -m option. If it is good, it
saves the MAC address from eeprom, program new eeprom binary file content into EEPROM and then restores
the original MAC address. It checks the validity of eeprom content once more at the end of programming.

Checking EEPROM content...............: passed


Loading EEPROM content from <file>....: passed
Programming EEPROM from <file>........: passed
Checking EEPROM content...............: passed

or

Checking EEPROM content...............: invalid


Loading EEPROM content from <file>....: passed
Programming EEPROM from <file>........: passed
Checking EEPROM content...............: passed

page 38
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-m only:

Program will check the validity of EEPROM. If it is not valid, it will act as a), -f -m option. If it is good,
the program will prompt the user for a new MAC address and program the MAC address only. It checks the
validity of EEPROM content once more at the end of programming.

Checking EEPROM content...............: passed


Programming MAC address...............: passed
Checking EEPROM content...............: passed

or

Checking EEPROM content...............: invalid


Loading EEPROM content from <file>....: passed
Programming EEPROM from <file>........: passed
Checking EEPROM content...............: passed

d) no -m and -f options

Program will check the validity of EEPROM. If it is not valid, it will act as a), -f -m option. If it is good, it
proceeds to normal diagnostics.

Checking EEPROM content...............: passed

or

Checking EEPROM content...............: invalid


Loading EEPROM content from [Link]: passed
Programming EEPROM from [Link]....: passed
Checking EEPROM content...............: passed

-pasf <filename> Program ASF firmware


This option needs to follow the –e and –c options. User has an option to program the ASF
firmware from a single bin file that combined all 3 pieces of ASF bin files or from a
specified text file that contain the file names of all 3 pieces of ASF bin files.
The program will detect input file type. If it is a single bin file, software will start
programming. If the input file is a text file that contains the file name of the 3 pieces of
ASF bin files, the program will retrieve the ASF firmware filenames from the specified text
file then it will start programming. A sample [Link] is provided and it has the following
format:asf_eep_init = [Link]
asf_eep_cpua = [Link]
asf_eep_cpub = [Link]

page 39
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-ppxe <filename> Program PXE firmware


This option needs to follow the –e and –c options. If this option is entered, the program will
retrieve the PXE firmware filename from the command line then it will start programming.
Example:
b57diag –e <code> -c 0 –ppxe [Link]

-mba <value> Enable/Disable Multiple Boot Agent


A value of 1 will enable Multiple Boot Agent and a 0 will disable.

Example:
b57diag –mba 0 : Disabling mba.

-mbap <value> Select Multiple Boot Agent Protocol


value = 0 : Selecting PXE
value = 1 : Selecting RPL
value = 2 : Selecting BOOTP

Example:
b57diag –mbap 0

-mbas <value> Select Multiple Boot Agent Speed


value = 0 : Selecting Auto
value = 1 : Selecting 10HD
value = 2 : Selecting 10FD
value = 3 : Selecting 100HD
value = 4 : Selecting 100FD

Example:
b57diag –mbas 0 : To select Auto speed mode.

-pxes <value> Select Multiple Boot Agent Speed


value = 0 : Selecting Auto

page 40
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

value = 1 : Selecting 10HD


value = 2 : Selecting 10FD
value = 3 : Selecting 100HD
value = 4 : Selecting 100FD

Example:
b57diag –mbas 0 : To select Auto speed mode.

-disableeswitch Disable E-Switch.

Act like engineering mode "eswitch -f" command. Disable the E-Switch on the device that
support eswitch, such as 5756. Without this option, PHY loopback test, external loopback
test (pkttest -e), and carrier test are performed on both laptop mode and docking mode.
With this option, above tests are performed on the default port.

-h : High Resolution (80x50) Video Mode


-p : Print on error
-q : Quick diagnostic mode
-asf <value> : Enable/Disable (value = 1/0) ASF in manufacture mode
-ipmi <value> : Enable/Disable (value = 1/0) IPMI in manufacture mode
-com <value> : enable com port, value(1..4)
-errctrl <c> : On Error -> a:abort w:wait l:loop c:cont s:skip
-ems <size> : Enter external memory size in HEX to test
-findref : Detect reference device
-lbm <n> : Option to set mac loopback packets
-lbp <n> : Option to set phy loopback packets
-lbe <n:n:n> : Option to set external loopback packets, Format:
<1000Mbps:100Mbps:10Mbps>
-npol : Select Negative Link Polarity in TBI test
-ref : Run test with reference device
-fail2 : On failure offset the failed message printout
-ctpm : Clears TPM data stored in NVRAM
-optmem : Option to allocate memory for optimization .
( For use with DOS B57diag on an EFI BIOS).

page 41
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-rc <filename> : Specify a script file to source after starting b57diag.


-run “<cmd> [options]”
: Execute a single command with its options after starting b57diag.

page 42
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

5 Recover device from corrupt NVAM


When vendor id and/or device id have been modified and B57diag can longer find the device, the
following steps can be followed to recover the missing device.
1. Use a PCI scan tool to scan all PCI devices in the system. Find out the vendor id and
device id of the missing device.
2. Run B57diag with –seldev option switch to detect the missing device.
e.g. a:\b57diag –b57eng –seldev 14e411677.
3. In B57diag engineering mode, clear the Magic value in the NVRAM.
e.g. 0:>sewrite 0 0
4. Reprogram the Bootcode firmware with “seprg” command.
5. Reboot system if needed.

page 43
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

6 [Link] format

A set of commands is defined to allow user to change [Link] content. To update


[Link], user must enter –e <code> -geneep options at the command prompt. A password
must be entered to run this option. The 5704, Dual MAC, device uses one single [Link] on
both MAC channel configurations. Most of the configurations are shared expect the following
commands:
PXE
PXE_SPEED
WOL
ASF

The WOL and ASF setting cannot be enabled on both channel at the same time. For example, if the
primary WOL is already enabled, and the user try to enable secondary device’s WOL, the primary’s
WOL setting will be disabled with the following message:

** Warning, primary device WOL is disabled


By default, all commands configure the primary channel until the command MAC is used to select
other channel.

Syntax:
<Command> = <Argument>
xx 8-bit hex number
xxxx 16-bit hex number
xxxxxxxx 32-bit hex number
d decimal number ranges from 0 to 255
string(n) string of maximum size n.
cc 2 bytes character
n1..n2 a number ranges from n1 to n2.

For Boot Code:


MAC = {0, 1}*
MAC_PREFIX = xx:xx:xx
MAC_ADDRESS = xx:xx:xx:xx:xx:xx
POWER_DISSIPATCHED = [Link]
POWER_CONSUMED = [Link]
SYSTEM_VENDOR_ID = xxxx
SYSTEM_DEVICE_ID = xxxx
SUBSYSTEM_VENDOR_ID = xxxx
SUBSYSTEM_DEVICE_ID = xxxx
PXE = {enable, disable}
PXE_SPEED = {auto, 10hd, 10fd, 100hd, 100fd, 1000fd}
WOL = {enable, disable}
CABLE_SENSE = {enable, disable}
PRODUCT_NAME = string (48)

page 44
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

PART_NUMBER = string (16)


ENGINEERING_CHANGE = string (10)
MANUFACTURING_ID = string (4)
ASSET_TAG = string (16)
FORCE_PCI = {enable, disable}
VOLTAGE_SOURCE = {1.3, 1.8}
LED_MODE = {mac_mode, triple_link /phy_mode1, link_speed/phy_mode2,
shared_traffic, shasta_mac, wireless_combo}
MAX_PCI_RETRY = {0..7, auto}
ASF = {enable, disable}
DUAL_MAC_MODE = {normal, mac0, mac1, xbar, swap, swapxbar} **
normal: Ch.0 and Ch. 1 enableds
macb: Ch.0 enabled, Ch.1 disabled
maca: Ch.0 disabled, Ch.1 enabled
xbar: Both MACs shares one function in PCI configuration space
swapxbar :
swap: swap between Ch.0 and Ch1.
MBA_BOOT_PROTOCOL = { pxe, rpl, bootp, iscsi}
MBA_BOOTSTRAP_TYPE = {auto, bbs, int18, int19}
MBA_DELAY_TIME = {0..15}
EXPANSION_ROM_SIZE = {64K, 128K, 256K, 512K, 1M, 2M, 4M, 8M, 16M}
DESIGN_TYPE = {nic, lom}
VENDOR_SPECIFIC0 = string (16)
VENDOR_SPECIFIC1 = string (16)
REVERSE_NWAY = {yes, no}
WOL_LIMIT_10 = {yes, no}
FIBER_WOL_CAPABLE = {yes, no}
CLOCK_RUN_SETTING = {enable, disable}
DISABLE_POWER_SAVING = {yes, no}
HIDE_MBA_SETUP_PROMPT = {enable, disable}
MBA_SETUP_HOT_KEY = {Ctrl-S, Ctrl-B}
ENABLE_AUTO_POWERDOWN = {yes, no}
CAPACITIVE_COUPLING = {enable, disable}
PRI_SMB_ADDR = {Hex(value)}
SEC_SMB_ADDR = {Hex(value)}
L1ASPM_Debounce_En = {enable, disable}

*This should only be used to select port for dual ports devices.
** This is for dual port devices only.

For Selfboot Firmware:


MAC_ADDRESS = xx:xx:xx:xx:xx:xx
SYSTEM_DEVICE_ID = xxxx
SUBSYSTEM_VENDOR_ID = xxxx
SUBSYSTEM_DEVICE_ID = xxxx
WOL = {enable, disable}
WOL_LIMIT_10 = {yes, no}
DESIGN_TYPE = {nic, lom}
ENABLE_AUTO_POWERDOWN = {yes, no}
REVERSE_NWAY = {yes, no}
DISABLE_POWER_SAVING = {yes,no}
CABLE_SENSE = {enable, disable}
LED_MODE = {mac_mode, phy_mode1, phy_mode2,
shared_traffic, shasta_mac, wireless_combo}
POWER_DISSIPATCHED _CONSUMED = [Link] *

page 45
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

PCIE_POWER_BUDGETING_DATA = x0:x1:x2:x3:x4 **
PRODUCT_NAME = {string (48)} ***
VPDR_SYSTEM_DEFAULT = 1 ****
PART_NUMBER = {string (16)}*****
ENGINEERING_CHANGE = {string (10)}*****
SERIAL_NUMBER = {string (16)}****
MANUFACTURING_ID = {string (4)}*****
VENDOR_SPECIFIC0 = {string (16)}*****

* If “d0” is 0, system default values will be selected. If “d0” is 1, suggested values will be used. If
“d0” is 2, user defined values will be used. “d1” = Power Dissipated value in D0 state. “d2” =
Power Dissipated value in D3 state. “d3” = Power Consumed value in D0 state. “d4” = Power
Consumed value in D3 state. Power Dissipated suggested value in D0 state is 100. Power
Dissipated suggested value in D3 state is 10. Power Consumed suggested value in D0 state is
100. Power Consumed suggested value in D3 state is 10.

** If “x0” is 0, system default value will be selected. If “x0” is 1, suggested default values will be
used. If “x0” is 2, user defined values will be used. “x1” = Power Budgeting Data 0 | Power
Budgeting Data 1. “x2” = Power Budgeting Data 2 | Power Budgeting Data 3. “x3” = Power
Budgeting Data 4 | Power Budgeting Data 5. “x4” = Power Budgeting Data 6 | Power Budgeting
Data 7.

*** User defined values will be used.


Suggested Product Name is “Broadcom NetXtreme Gigabit Ethernet Controller”

**** If “VPDR_SYSTEM_DEFAULT = 1” has been entered, System default value for all VPD-R data
will be selected.

*****User defined values will be used.


Suggested Part Number is “BCM957xx”
Suggested Engineering Change Number is “106679-15”
Suggested Serial Number is “0123456789”
Suggested Manufacturing ID is “14e4”
Suggested Vendor Specific Data is “”

Option f has been combined with option e in secfg for Selfboot Firmware.

0:>secfg
1. MAC Address ……......................................: 001018000000
2. Device Id ……………………………...........: 1693
3. Sub Vendor Id …….....................................: 14E4
4. Sub Device Id …………………………......: 1693
5. Wake on LAN …….....................................: Disabled
6. WoL Speed Limit 10 .…………………….: Disabled
8. LED mode …………………………….…..: Disabled
9. VPD Prod. Name and VPD-R Data ..........: Disabled
a. Super-airplane Mode ……………………..: Disabled

page 46
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

b. MBA Configuration
c. NIC Design ………………………….…......: LOM
d. L1 PLL Disable …………………………..: Yes
e. Clkreq ……………………………………..: No
f. PCIE Link Polarity Fix Dis ……………….: No
g. L1ASPM Debounce En ……………………: Yes

x. Save & exit

-------------------------------------- Custom VPD Data (option 9)----------------------------------------

HW Selfboot VPD Data

1. Part Number : BCM957xx


2. Engineering Change : 106679-15
3. Serial Number : 0123456789
4. Manufacturing ID : 14e4
5. Read only VPD Vendor Specific Data (V0) :
6. Product Name : Broadcom NetXtreme Gigabit Ethernet Controller

E Custom VPD Data Reference


Description:
VPD Product description string.
e-1 Part Number Reference
Description:
VPD part number..
e-2 Engineering Change Reference
Description:
VPD engineering change.
e-3 Serial Number Reference
Description:
VPD serial number.
e-4 Manufacturing ID Reference
Description:
VPD manufacturing ID.
e-5 Read only VPD Vendor Specific Data (V0) Reference
Description:
VPD V0 value. Data field provided for the customer.
e-6 Product Name Reference
Description:
VPD Product description string.

Example 1:

page 47
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

; This is comment line


// This also can be used as comment line

// Blank line is also allowed

// This is Broadcom’s MAC prefix


MAC_PREFIX = [Link]
POWER_DISSIPATCHED = [Link]
POWER_CONSUMED = [Link]
SUBSYSTEM_VENDOR_ID = 14e4
SUBSYSTEM_DEVICE_ID = 1644
pxe = disable
PXE_Speed = 100fd
WOL = enable
Product_name = Broadcom Gigabit Ethernet Controller
PART_NUMBER = BCM95700A6
ENGINEERING_CHANGE = 106679-15
MANUFACTURING_ID = 14e4
Asset_Tag = XYZ1234567
DUAL_MAC_MODE = normal
MBA_BOOT_PROTOCAL = pxe
MBA_BOOTSTRAP_TYPE = bbs
MBA_DELAY_TIME =6
EXPANSION_ROM_SIZE = 128K
DESIGN_TYPE = nic
; select other channel
MAC = 1
PXE = enable

Example 2:
; A. Super-airplane Mode (enable/disable)
super_airplane_mode = disable
; C. NIC Design (nic/lom)
nic_design = lom
; D. L1 PLL Disable (yes/no)
l1_pll_disable = no
; E. Clkreq (enable/disable)
ClkReq = disable
; F. PCIE Link Polarity Fix Dis (yes/no)
pcie_link_polarity_fix_dis = no
; G. L1ASPM Debounce En (yes/no)
L1ASPM_Debounce_En = no
; MBA 1. VLAN Enable (yes/no)
vlan_enable = yes
; MBA 2. VLAN ID (0..4095)
vlan_ID = 4095
; MBA 8. LINK SPEED (auto/10hd/10fd/100hd/100fd)
link_speed = 10fd

page 48
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

7 User Interface Commands

The commands are summarized in the following groups: vpd, nvram, cpu, dma, packet, mii, mem,
test, power, irq, mac, misc, bridge and uart.

Note: For UEFI version, not all tests are supported. Refer to online help for more information.

Command Group 'vpd'


vpdwrite Write VPD Memory
vpdread Read VPD Memory
vpdinfo Show VPD Information

Command Group 'nvram'


semode Same as flshmode command
seread Read NVRAM
sewrite Write NVRAM
secfg Configure NVRAM
seprg Program NVRAM
uprg Program userblock
upgfrm Upgrade PXE or Boot Code from a File
sever Display Serial NVRAM Version
sechksum Check/Update Serial NVRAM checksum
sedump Dump NVRAM content to a file
flshmode Configure NVRAM mode
flshread Same as seread
chkpxe Check PXE code image
dir Display file directory in NVRAM
iscsiprg Program iSCSI from a File
erase Erase file from directory in NVRAM
pxeprg Upgrade PXE from a File
flshdev Select flash device to access
bitbang Generate BitBang pattern to SEEPROM bus
seclock Set NVRAM config1 content value after reset
setorture NVRAM reset torture test
seinit Initialize NVRAM block
searb Set/Report current NVRAM arbitration bit
seprotect Set GPIO pin for NVRAM write protect
selclock Set Legacy EEPROM clock value (bit 16-24 of EEPROM
addr reg)
semap Display NVRAM usage
setwol Enable/Disable WOL
setpxe Enable/Disable PXE
secomp Compare EEPROM content against the file
dreset Double reset test for EEPROM debug
userblock Create a userblock in NVRAM
setmba Enable Multiple Boot Agent
segencrc Append a CRC to the specified block
secfghwsb1 Configure HW SelfBoot NVRAM
secfghwsb2 Configure HW SelfBoot NVRAM Group 2
secfghwsb3 Configure HW SelfBoot NVRAM Group 3
secfgsb1 Configure SelfBoot NVRAM
secfgsb2 Configure SelfBoot NVRAM Group 2
secfgsb3 Configure SelfBoot NVRAM Group 3
secfg1 Configure NVRAM Group 1
secfg2 Configure NVRAM Group 2
secfg3 Configure NVRAM Group 3

page 49
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

secfg4 Configure NVRAM Group 4


secfg5 Configure NVRAM Group 5
dirw Write a directory entry to NVRAM
tpm Write a directory entry for the TPM Block
umpcfg Configure UMP in NVRAM
setipmi Enable/Disable IPMI Passthrough Firmware
setump Enable/Disable UMP
seotp Configure OTP
otpchk Check patch in OTP
defragment Defragment NVRAM

Command Group 'cpu'


loadfw Load Firmware to Tx/Rx CPUs
cpudtt Dump Debugging Trace of TX CPU
cpudrt Dump Debugging Trace of RX CPU
cputrace Toggles CPU trace mode
haltcpu Halt CPU
loadbootcode Execute bootcode from file instead of NVRAM
disasm Disassemble MIP instructions
step Step MIP instructions
go Start CPU
showgpr Toggles showing CPU GPR mode
pc Set current CPU program counter
breakpoint Set current CPU break point
select Select current CPU
u Alias of disasm command
trap Trap CPU memory
cpuinfo Display CPU information
cpualive Probe CPU if it is alive
cpumemstatus Display internal CPU Memory test status
cpumemstart Start internal CPU Memory test
cpumemstop Stop internal CPU Memory test
cpumemset Set internal CPU Memory test location
cpursttest CPU Reset Test
cpufetch CPU instruction fetch logic test
romcodetest ROM Code Test

Command Group 'dma'


dmaw DMA from NIC to Host Memory
dmar DMA from Host to NIC Memory
dma_h Dump DMA Entries
dma_d Dump DMA Entries with Decode
dma_alloc Allocate number of DMAD

Command Group 'packet'


maclpk Configure MAC loopback
blast Blast Packets in Poll Mode
nicstats Display NIC Statistics
ringindex Dump Ring Index
phyctrl Force Speeds/Duplex
txpkt Transmit Packet
statusblk Dump Status Block
stsblk Dump Statistics Block
txcfg Configure protocol packets for transmission
txsrcip Configure source IP address for transmission
txdstip Configure destination IP address for transmission
txsrcport Configure source port address for transmission
txdstport Configure destination port address for transmission
txtype Configure packet type for transmission

page 50
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

txprot Configure packet protocol field for transmission


txipprot Configure packet IP protocol for transmission
rxcfg Configure Rx parameters
tprot Blast with TPROT Packets
qstat Get a quick NIC statistic
drvrcfg Configure driver parameters
irt Test an individual register
macmrd Test an individual register
miimrd Test an individual register
miiloop Test an MII/MII EXP/ MII TAP register
pcimrd Test an individual register
inband Force inband

Command Group 'mii'


mwrite Write PHY registers via MII Management interface
mread Read PHY registers via MII Management interface
msread1c Read PHY Shadow registers 0x1C via MII Management
interface
msread18 Read PHY Shadow registers 0x18 via MII Management
interface
readexp Read PHY Expansion Registers via MII Management interface
sdwrite Write SERDES registers via MII Management interface
sdread Read SERDES registers via MII Management interface
mdev Select current PHY to be accessed
miimode Select Auto Mode of MII Access
lbertram Load data to PHY BIST RAM
dbertram Dump PHY BIST RAM
bertstats Dump PHY BIST Statistics
rm Read MII Registers
mrloop Loop on MII read
phymse PHY mean square error
initphy Initialize PHY
tapdump Read PHY internal TAP values
m2dev Select current PHY to be accessed

Command Group 'mem'


memsearch Search for a data pattern in memory
read Read Memory
write Write Memory
poll Poll Memory
setbit Read-Modify Memory by ORing with <bits>
clearbit Read-Modify Memory by ANDing with ~<bits>
readbit Read-Modify Memory by ored with <bits>
cread Read PCI configuration space of specified device
cwrite Write PCI configuration space of specified device
pcird Read PCI Configuration Word
pciwr Write PCI Configuration dWord

Command Group 'test'


vpdtest Run VPD Memory Test
regtest Run Register Test
miitest Run MII Memory Test
msi Run MSI Test Manually
memtest Run Memory Test
setest Run NVRAM Test
bist Run BIST
nictest Run a set of NIC Tests
intrtest Run Interrupt Test
pkttest Run Packet Tests

page 51
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

cputest Run CPU Test


dmatest Run DMA Test
teste Enable Test
testd Disable Test
asftest ASF Test
bustest PCI Bus Test
sramtest SRAM test
msitest Run MSI Test
romtest ROM Test
gpiotest Do GPIO test
cpudiag Run diagnostic from internal CPU
pcicfgtest Run PCI Config. Reg. Test
petest Perform parity error test on a bridge
errctrl Configure Error Control Setting
sedvt Perform NVRAM dvt test
miimisctest Run MII Misc. Tests
cpugprtest Run CPU GPR test
carriertest Run False Carrier Test
wseq Run Sequential Write Test
umplb UMP Loopback Test
dmashasta Run DMA Test On Shasta Family Of Devices
apetest Run APE Self Tests

Command Group 'power'


pmdcfg Dump Power Management Info
pmpcfg Add/Del Pattern
pmpd Power Down MAC

Command Group 'irq'


intr Dump Interrupt Info
intrctrl Mask/Unmask Current Interrupt
intt Interrupt Tracer

Command Group 'mac'


mbuf Dump Content of MBUFs
loaddrv Load Driver
unloaddrv Unload Driver
machalt Halt MAC Controller
ftq Dump FTQ
addmc Add Multicast MAC
delmc Delete Multicast MAC
txmacdes Program Destination address to UUT
txmacsrc Program Source address to UUT
chklddrv Check to see if driver is loaded
vlantag Display/Clear vlan tag information

Command Group 'misc'


reg Register wizard
exit Exit the System
debug Debug functions
gpiowrite Write a Value into GPIO pin
gpioread Read GPIO Value
pxecpy Load PXE Code to MBUF Memory
device Show or Switch Device
version Display Program Version
help Display the Commands Available
? Alternate Help Command
radix Change System Radix
apeaccmode Select between BAR1 Mode and Indirect Access Mode

page 52
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

nolog Close the Current Logfile


log Open Logfile
pciinit Initialize PCI Configuration Registers
pciscan Scan for All PCI Devices
dos Execute DOS command
diagcfg Configure Diagnostics
reset Reset Chip
sadbtest SADB test for IPSec supported devices
sadbutil Utilities for SADB table, only valid for IPSec supported
devices
quit Exit the System
cls Clear Screen
loop Loop on a command
dbmode Set DEBUG Mode to On or Off Mode
new Display new commands available
sleep Suspend command execution
fillpattern Fill WOL matching pattern into Misc. Memory Location
inp Input port
outp Output port
switch Alternate 'device' command
do Execute commands from a file
txfill Fill tx buffer with pattern and packet length (14-9018)
wbuf Write tx|rx buffer with specified data at offset
rbuf Read tx|rx|bistin|bistout|bistex buffer
cpbuf Copy the content of rx buffer into tx buffer
echo Echo <string> to the screen
pause Pause for user to hit a key
q Exit the System, alias name for quit
verbose Change verbose settings
beep Create a beep sound
var Display current variables
meminfo Report memory information
delvar Delete local variables
regdump Dump register content to a file
regcomp Compare register content to a file
regrestore Restore register content from a file
showcurrcard Dump Current Card Info
showglobal Dump Global Info
nvsize Programs the NVRAM and TPM size in Kbyte to NVRAM
aspm Configure PCI-E Link power state operation
ledcfg Configure the LED Mode (Shasta Specific)
ledblink Blinks the LED
nmbuf Select No. of Mbuf
umpecho UMP Echo Test
dids Display detail device information for all devices
serial Compares the serial no. to defaults or the provided values
power Verify the operation of the power capability (575x Cx
specific)
binchksum Run Checksum test on input firmware file
eswitchtest Run E-Switch Timer Test
eswitch Switch E-Switch between Docking and Laptop
sbfcfg Self-boot file config.
linkintrtest Link Changed Interrupt Test
ipv6extld Load IPv6 Extension Header File
ipv6exten Enable IPv6 Extension Headers (1=En, 0=Dis)
cfgpagesize Configure Flash page size to 256B or 512B
cpmu CPMU tests
mdio MDIO tests
wait delay a bit
ipsecsupport To check if the device support IPSec.

page 53
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Command Group 'man'


asfcfg Configure Management Firmware in NVRAM (AKA mancfg)
mancfg Configure Management Firmware in NVRAM or configuration
file
asfprg Program ASF firmware into NVRAM (3 bin files)
smbusrun Operate SMBUS in Auto or BitBang mode
smbusmode Set SMBUS in Auto or BitBang mode
setasf Enable/Disable ASF Firmware (AKA setman)
setman Enable/Disable Management Firmware
asfmbox Create or Read ASF Mailboxes
asfeng Enable/Disable ASF engineering mode
apeinfo Display APE-related information
apectl Control APE
apeping send APE event to ping host from APE
aperead Read APE local view data thru APE
apeotpkey Print APE OTP key value
apelog Create, view, and manage NVRAM-based APE Logs

Command Group 'bridge'


readbr Read bridge's configuration space
writebr Write to bridge's configuration space
findbridge Find all PCI bridges in the system
bridge Switch to specified bridge
pere Enable parity error response on a bridge
perd Disable parity error response on a bridge
peclr Clear parity error on bridge
pechk Clear parity error on a bridge

Command Group 'uart'


uart Disable/Enable/Access/Test Virtual UART

page 54
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

8 Special Instruction

1. Mac register test:

Unload MAC driver before running test.

2. Memory test:

Unload MAC driver before running test.

3. DMA test:

Unload MAC driver before running test.

4. TX RX packets:

TX sides need to be configured (txcfg).

RX sides need to be configured (rxcfg).

Configure MAC and PHY loop back.

Call txpkt to transmit packets.

5. The following tests need to setup test configuration before running.

To setup test configuration, run "diagcfg". Diag config can be saved in system for future
use.

Test:

Memory test

NIC test

6. Unload driver before power down NIC card.

7. Load driver after power up NIC card.

8. Blast Test:

Load MAC driver before running test.

page 55
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

9 Same System Send/Respond Test

During a send/respond test two Broadcom Ethernet devices in the same system are
connected via a CAT5 (RJ45) cable and data is transmitted and received across the cable. In
the above setup one device is the device under test (DUT) and the other is the reference
device. Any Broadcom device that is supported by diagnostics can be used as the DUT or
the reference device.

9.1 Identifying a reference device


A reference device needs to be identified in order to test a DUT against the reference
device. The user can use the “b57diag –dids” command to display all the devices in the
system. Each device is assigned a number that is displayed on the screen in the first column
just before the device type. A user selects the number of the device that is to be used as the
reference and uses this number to test the DUT as described in the next section.

9.2 Testing the DUT against the reference device


After identifying the reference device, as described in the previous section, the user can test
the DUT by running “b57diag –rf 0 –c 1 –t abcd –T d3”. Each of the previous options are
described in the table below (details of each option are provided in the “Command line
option parameters” section above).

-rf 0 Identifies the reference device as device 0.

-c 1 Identifies the DUT as device 1.

–t abcd Disables all tests (Disable all tests in group a, b, c, and d).

–T d3 Perform the external loopback test that will transmit data from the DUT to the
reference device, via the CAT5 cable, then the reference device will receive
the data and transmit it back, via the CAT5 cable, to the DUT which will
verify the received data.

9.3 Other Options for the Send/Respond test


The following options can be used with the send/respond test (details of each option are
provided in the “Command line option parameters” section above).

-lbspd t/h/g Selects any combination of line speed to run the loopback test (by
default runs all line speeds).

–lbe g:h:t Selects the number of packets to send during the loopback test (g, h & t
are the 1000/100/10 megabit packet counts respectively) (default values
are g=2000, h=1000, t=600). It is mandatory that all packets counts are
entered with this command line switch.

page 56
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10 Test and Functions Description

10.1 vpdwrite
Command: vpdwrite

Description: Write data to VPD storage.

Syntax: vpdwrite <start[-end | len] value> | <filename>

File format:

Address range: 0x00 – 0xFF

num_bytes: 256 (max)

If only one argument is entered, filename is assumed. Otherwise, 'start [len] value' format
must be used.

10.2 vpdread
Command: vpread

Description: Read data from VPD storage

Syntax: vpdread start[-end | len]

Address range : 0x00 – 0xFF

num_byte : 256 (max)

10.3 vpdinfo
Command: vpdinfo

Description: Show VPD Information

Syntax: vpdinfo

10.4 semode
Command: semode

Description: Configure NVRAM Mode.

Syntax: semode [auto | passthru | legacy | new]

Example:

page 57
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

1. Set Serial EEPROM mode to Auto.


0:> semode auto

2. Display Current mode


0:> semode
Current mode : New NVRAM Access, Auto
device: Flash – ATMEL (with buffer)

10.5 seread
Command: seread

Description: Read NVRAM

Syntax: seread start[-end | len]

Note: Use “semode” command to configure the interface mode.

Example:

1. Set number base to hex, then read and display serial eeprom locations from 0x00 to
0x20
0:> radix 16
0:> seread 0-20
*** Dump Serial EEPROM (Auto Mode) ***
000000: 669955aa 08000000 00000069 00000200 d97b07d0 00000000 00000000 00000000

000020: 00000000

2. Set number base to hex then read location 0x18 of serial eeprom.
0:> radix 16
0:> seread 18 1
*** Dump Serial EEPROM (Auto Mode) ***
000018: 000000ff

10.6 sewrite
Command: sewrite

Description: Write NVRAM

Syntax: sewrite start[-end | len] data

Note: Use “semode” command to configure the interface mode.

Example:

1. Set number base to hex, write 0x55AA to serial eeprom from locations 0x30 to 0x35
0:> radix 16
0:> sewrite 30-35 55AA
*** Write Serial EEPROM (Auto Mode) ***

page 58
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

2. Set number base to hex, write 0x2 to serial eeprom location 0x25
0:> radix 16
0:> sewrite 25 2
*** Write Serial EEPROM (Auto Mode) ***

10.7 secfg
Command: secfg

Description: Configure Boot Code or Selfboot firmware.

All option is for Boot Code only. If selected program with defaults (-f=1), [Link]
must be found in the same directory of [Link].

Syntax: secfg

Options:

-v<n> : verbose level (0,1,2) (def=0)

-f : force to program with defaults

Example: (For Boot Code).

1 Program Serial EEPROM with defaults value and set verbose level to 0.
0:> secfg
Reading current NVRAM ... OK
Validating content...

1. MAC Address : [Link]


2. Power Dissipated ([Link]) : [Link]
3. Power Consumed ([Link]) : [Link]
4. Vendor ID : 14E4
5. Vendor Device ID : 1653
6. Subsystem Vendor ID : 14E4
7. Subsystem Device ID : 1653
8. PXE (does not apply to PXE in system ROM)
{ Enable(1), Disable(2) } : Disable
9. PXE Link Speed { Auto(0),10HD(1),10FD(2)
100HD(3),100FD(4) }: Auto
10. Magic Packet WoL { Enable(1), Disable(2) } : Disable
11. Product Name : Broadcom NetXtreme Gigabit Ethernet Controller
12. Part Number : BCM95705A50
13. Engineering Change : 106679-15
14. Serial Number : 0123456789
15. Manufacturing ID : 14e4
16. Asset Tag : XYZ01234567
17. Part Revision : A0
18. Voltage { 1.3V(0), 1.8V(1) } : 1.8V
19. Force PCI Mode { Enable(1),Disable(2) } : Disable
20. PHY Type { Copper(1),Fiber(2) } : Copper
21. Led Mode { Mac Mode(0), Phy Mode1 (1), Phy Mode2 (2),
Shasta Mac Mode (3), SharedTraffic (4),
Wireless Combo (5)} : Phy Mode1
22. PHY ID ([PHY#2][PHY#3]) : 00206160
23. Max PCI Retry {0-7, 8=auto} : 8
24. Advanced firmware feature (ASF/IPMI/UMP)
{ Enable(1), Disable(2) } : Disable

page 59
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

25. Dual MAC mode {Normal(0), MAC_B only(1)


MAC_A only(2), XBAR(3), swap(4), swapXBAR(7)}: 0
26. MBA Boot Protocol {PXE(0), RPL(1), BOOTP(2),
iSCSI(3)} : 0
27. MBA Bootstrap Type
{Auto(0), BBS(1), Int18(2), Int19(3)}: 0
28. MBA Delay Time (0-15) : 0
29. Expansion ROM size (does not apply to PXE in system ROM)
{ 64k(0), 128k(1), 256k(2),512k(3), 1M(4), 2M(5),
4M(6), 8M(7), 16M(8) } : 0
30. Design Type: {NIC(0), LOM(1)} : NIC
31. Read only VPD Vendor Specific Data (V0) :
32. Read/Write VPD Vendor Specific Data (V1) :
33. Reversed Nway {No(0), Yes(1)} : No
34. Limit WoL Speed to 10 {No(0), Yes(1)} : No
35. Fiber WoL Capable {No(0), Yes(1)} : No
36. Clock-Run Setting {Disable(0), Enable(1)} : Disable
37. Enable PHY Auto Powerdown {No(0), Yes(1)} : No
38. Disable PowerSaving capability {No(0),Yes(1)}: No
39. Hide MBA Setup Prompt {Disable(0), Enable(1)}: Disabled
40. MBA Setup Hot Key {Ctrl-S(0), Ctrl-B(1)} : 0
41. Capacitive Coupling (5705 only)
{Disable(0), Enable(1)} : Disabled
42. SERDES TX Drvr Pre-Emp - Primary (5704 only) : 0
43. SERDES TX Drvr Pre-Emp - Second (5704 only) : 0
44. SERDES TX Drvr Pre-Emp - ENABLE (5704 only)
{Disable(0), Enable(1)} : Disabled
46. Encoded Hot Plug Power Value 1 & 2 For NIC : 00000000
47. Encoded Hot Plug Power Value 3 & 4 For NIC : 00000000
48. Encoded Hot Plug Power Value 5 & 6 For NIC : 00000000
49. Encoded Hot Plug Power Value 7 & 8 For NIC : 00000000
50. Hot Plug Power {Disable(0), Enable(1)} : Disabled
51. Pri. Port SMB Address (ASF/IPMI) : A4
52. Sec. Port SMB Address (IPMI) : A6
53. Cable Sense/Low Power Energy Detect {Disable(0), Enable(1)} : Disabled
54. GPIO 0 Config {Input(0), Output Hi(1),
Output Lo(2)} : Input
55. GPIO 2 Config {Input(0), Output Hi(1),
Output Lo(2)} : Input
56. L1ASPM Debounce En {Disable(0), Enable(1)} : Disabled
57. Link Aware Mode {Disable(0), Enable(1)} : Enabled
58. Link Speed Power {Dis able(0), Enable(1)} : Enabled

Enter your choice (option=paramter/save/cancel) ->

Description of above parameters:

To enter the ‘secfg’ menu shown above a user type in ‘secfg’ at the diagnostics command
line. A menu is present to the user showing the ‘secfg’ options shown above. A user can
change the ‘secfg’ parameter by entering the option number, followed by and equal sign,
and then followed by the parameter selected. To enable ASF (option 24) a user would enter
“24=1” at the diagnostics ‘secfg’ command line, which would look like the following:
“Enter your choice (option=paramter/save/cancel) -> 24=1”.

The tables below provide details for each parameter of the ‘secfg’ options. The top right of
each table has the word “Configure” or “Reference”. “Configure” signifies that the
option is used to configure the operating characteristics of the device or default values of
registers in the device. “Reference” signifies that the option is use for display purposes and
does not affect the operating characteristics of the device or default values of registers in

page 60
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

the device.

1 MAC Address Configure


Description:
MAC address of the device.
2 Power Dissipated ([Link]) Reference
Description:
Power dissipated in D3-0 states.
3 Power Consumed ([Link]) Reference
Description:
Power consumed in D0-2 states.
4 Vendor ID Configure
Description:
PCI Vendor ID. Default 0x14e4.
5 Device ID Configure
Description:
PCI Device ID.
6 Subsystem Vendor ID Configure
Description:
PCI Subsystem PCI Vendor ID.
7 Subsystem Device ID Configure
Description:
PCI Subsystem PCI Device ID.
8 PXE Configure
Description:
Enable the Pre-Boot Execution Environment (PXE) by using this option. This option does
not apply to PXE in system ROM. Options 8,9, 26 - 29 and 39-40 configure the boot
protocol behavior.
Enable(1) When PXE is enable the expansion ROM enable bit in the PCI
configuration space is set for system boot up. The user has to make
sure the PXE code is loaded into the non-volatile memory by using the
“loadpxe” command.
Disable(2) When PXE is disable the expansion ROM enable bit in the PCI
configuration space is cleared for system boot up. The PXE code does
NOT have to been load into the non-volatile memory of the device.
9 PXE Link Speed Configure
Description:
Pre-Boot Execution Environment line configuration is specified using the parameters below.
Options 8,9, 26 - 29 and 39-40 configure the boot protocol behavior.
Auto(0) PXE auto detects the link configuration.
10HD(1) PXE uses a 10 Mbits/s, half duplex line configuration.
10FD(2) PXE uses a 10 Mbits/s, full duplex line configuration.
100HD(3) PXE uses a 100 Mbits/s, half duplex line configuration.
100FD(4) PXE uses a 100 Mbits/s, full duplex line configuration.
10 Magic Packet WoL Configure
Description:
A system can be configured to power-on when a Magic Packet is received.

page 61
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Enable(1) The device will assert the pme signal, to power on the system, when a
magic packet is received.
Disable(2) Magic packets are ignored.
Note:
A driver can setup the WoL behavior of a device and the value programmed into this
location is ignored.
11 Product Name Reference
Description:
VPD Product description string.
12 Part Number Reference
Description:
VPD part number..
13 Engineering Change Reference
Description:
VPD engineering change.
14 Serial Number Reference
Description:
VPD serial number.
15 Manufacturing ID Reference
Description:
VPD manufacturing ID.
16 Asset Tag Reference
Description:
VPD asset tag.
17 Part Revision Reference
Description:
VPD part revision.
18 Voltage (5701 only) Configure
Description:
Controls the voltage source level for the 5701 controller.
1.3V(0) Selects a 1.3V source.
1.8V(1) Selects a 1.8V source.
19 Force PCI Mode Configure
Description:
PCI bus operational mode configuration.
Enable(1) When enabled the device uses PCI mode, instead of PCI-X,
independent of the capabilities of the slot the device is plugged into.
Disable(2) When disabled the device uses the PCI mode of the slot the device is
plugged into; if the device is capable of operating in the required mode.
20 PHY Type {option no longer supported} Configure
Description:
PHY line type configuration.
Copper(1) The communication medium is copper.
Fiber(2) The communication medium is fiber.

page 62
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

21 Led Mode Configure


Description:
A device can be configured to use one LED to indicate speed and activity or three LEDs.
Use a devices data sheet to verify the LED modes supported by a devices and for
exceptions to the LED modes described below.
Mac Mode (0) The LEDs are controlled by the value in the Mac LED Control Register.
Phy Mode1 (1) Three LEDs are used for 10/100/1000 Mbits/s and each is driven
individually by the device.
Phy Mode2 (2) One LED is used for 10/100/1000 Mbits/s and is connected as described
below.

5700/01 – The Link10 line will indicate link for all speeds. Link100 and
Link1000 will encode the line speed as show in the following table:
Link 100 Link 1000 Speed
0 0 10 Mbits/s
1 0 100 Mbits/s
0 1 1000 Mbits/s

For all other 57xx devices the three link lines operate in an open drain
configuration and can be tied together with a pull up resistor to control a
LED.
SharedTraffic Mode specific to the 575x and 572x chips. The link LED performs a dual
(3) role: solid when there is a link and blinks when there is activity.
Shasta Mac Mode specific to the 575x and 572x chips. The link LED blinks only when
Mode (4) traffic is for Shasta.
Wireless Mode specific to the 575x and 572x chips. When link is lost the LEDs are
Combo (5) driven by inputs pins that are connected to the LED signals of a wireless
link.
22 PHY ID Reference
Description:
Only for display purposes not used in software.
[PHY#2][PHY#3]
23 Max PCI Retry Configure
Description:
The maximum number of time to retry an aborted PCI operation.
0-7 The number of MAX PCI retries is force by the users configuration.
8=auto The MAX PCI retry field is selected dynamically by firmware based on
PCI bus type detected.
24 Advanced firmware feature (ASF/IPMI/UMP) Configure
Description:
Advanced firmware feature such as Alert Standard Format (ASF) or IPMI is enabled by this
option.
Enable(1) If the ASF/IPMI/UMP code is loaded in NVRAM it is loaded and
executed by the device.
Disable(2) No ASF/IPMI/UMP functionality is provided when disable.
25 Dual MAC mode Configure
Description:
This option is only valid for a dual port device such as a 5704. The physical ports will be
named MAC_A and MAC_B for the discussion below.
Normal(0) MAC_A and MAC_B are available and are supported as PCI function 0
& 1.
MAC_B only(1) MAC_B is available and is supported as PCI function 0. MAC_A is
disable.

page 63
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

MAC_A only(2) MAC_A is available and is supported as PCI function 0. MAC_B is


disable.
XBAR mode(3) MAC_A and MAC_B are available and are supported as PCI function 0.
MAC_A is the primary device and MAC_B is mapped in the space of
MAC_A. To the OS and BOIS this looks like one port. The driver will
trunk the two ports together as one logical port which allows for load
balancing, failover/recovers, turbo-teaming, etc.
swap(4) Physical port MAC_A and MAC_B are available and are supported as
PCI function 1 and 0 respectively.
swapXBAR(7) MAC_A and MAC_B are available and are supported as PCI function 0.
MAC_B is the primary device and MAC_A mapped in the space of
MAC_B. To the OS and BOIS this looks like one port. The driver will
trunk the two ports together as one logical port which allows for load
balancing, failover/recovers, turbo-teaming, etc.
26 MBA Boot Protocol Configure
Description:
Select a Multiple Boot Agent. Options 8,9, 26 - 29 and 39-40 configure the boot protocol
behavior.
PXE(0) PreBoot Execution Environment (PXE) is the boot protocol.
RPL(1) Remote Program Load (RPL) is the boot protocol.
BOOTP(2) Boot Protocol (BOOTP) is the boot protocol.
ISCSI(3) ISCSI is the boot protocol.
27 MBA Bootstrap Type Configure
Description:
The BIOS bootstrap methods listed below are supported. Options 8,9, 26 - 29 and 39-40
configure the boot protocol behavior.
Auto(0) Automatically configured use one of the methods below.
BBS(1) A BIOS that supports the BIOS Boot Specification (BBS) can initiate the
bootstrap method via the expansion ROM Bootstrap Entry Vector.
Int18(2) An INT18 is used to initiate the bootstrap method.
Int19(3) An INT19 is used to initiate the bootstrap method.
28 MBA Delay Time Configure
Description:
The amount of time the MBA boot message is displayed, in order to give a user the option
to enter the BOOT parameter configuration screen.
0-15 The number of seconds the MBA banner is displayed.
29 Expansion ROM size Configure
Description:
This value determines the size of the expansion ROM. This option does not apply to PXE
in system ROM. Options 8,9, 26 - 29 and 39-40 configure the boot protocol behavior.
64k(0) Advertises 64k expansion ROM size.
128k(1) Advertises 128k expansion ROM size.
256k(2) Advertises 256k expansion ROM size.
512k(3) Advertises 512k expansion ROM size.
1M(4) Advertises 1M expansion ROM size.
2M(5) Advertises 2M expansion ROM size.
4M(6) Advertises 4M expansion ROM size.
8M(7) Advertises 8M expansion ROM size.
16M(8) Advertises 16M expansion ROM size.
30 Design Type Configure

page 64
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Description:
Select NIC or LOM based Ethernet controller.
NIC(0) Option selected for a plug in network interface card.
LOM(1) Option selected for a LAN on motherboard.
Note:
The firmware and the drivers use this to determine the operational characteristics of a
device. For example, on a LOM GPIO2 is tied to the SEEPROM write protect pin and on a
NIC GPIO 1 and 2 is used to switch between main and auxiliary power for wake on LAN
functionality.
31 Read only VPD Vendor Specific Data (V0) Reference
Description:
VPD V0 value. Data field provided for the customer.
32 Read/Write VPD Vendor Specific Data (V1) Reference
Description:
VPD V1 value. Data field provided for the customer.
33 Reversed Nway Configure
Description:
Nway Negotiation.
0 (default) Auto-negotiation is done from 1000->100->10 Mbits/s.
1 Auto-negotiation is done from 10->100->1000 Mbits/s.
Note:
A user could set the chip for option 1 when running a laptop on battery power. The chip
would auto-negotiate starting at a lower speed and lower power. The chip would only go to
higher line rates and higher power if the lower line rates were unavailable.
34 Limit WoL Speed to 10 Configure
Description:
Limit Wake on LAN (WoL) line speed.
No(0) 10 or100 Mbits/s is used for WoL.
Yes(1) Only 10 Mbits/s is used for WoL.
35 Fiber WoL Capable Configure
Description:
Fiber Wake on LAN (WoL) Capable enable.
No(0) Disable Fiber WoL.
Yes(1) Enable Fiber WoL.
36 Clock-Run Setting Configure
Description:
Enable Clock-Run on mini-PCI/cardbus systems. This parameter is valid only for the 5705
A0-A2.
Enable(1) Sets the clock mode register bit 22 which will assert (active low) the
clock run signal on the bus prior to any PCI configuration space activity.
Disable(0) The above is not performed.
37 Enable PHY Auto Powerdown Configure
Description:
Enable GPHY auto-power down when there is no link present (to conserver power).
No(0) The PHY will not auto power down.
Yes(1) The PHY will auto power down when there is no link.
38 Disable Power Saving capability Configure
Description:
Disable Power Saving capability setup by option 33 above. When disable a device will use
Nway negotiation.

page 65
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

No(0) Power-saving capability active.


Yes(1) Power-saving capability inactive.
39 Hide MBA Setup Prompt Configure
Description:
During the MBA boot, the MBA setup prompt is displayed to provide the user the option to
setup and configure various MBA parameters. Options 8,9, 26 - 29 and 39-40 configure the
boot protocol behavior.
Disable (0) Hide the MBA Setup Prompt. The user is NOT give the option to change
the MBA boot parameters.
Enable (1) Show the MBA Setup Prompt. The user is given the option to change the
MBA boot parameters.
40 MBA Setup Hot Key Configure
Description:
Hot Key used to enter the MBA Setup. Options 8,9, 26 - 29 and 39-40 configure the boot
protocol behavior.
Ctrl-S (0) MBA Setup entered via ctrl-s.
Ctrl-B (1) MBA Setup entered via ctrl-b.
41 Capacitive Coupling Configure
Description:
Enable/Disable the PHY to operate with capacitors as line isolators for the 5705 family.
Disable (0) Disable capacitive coupling.
Enable (1) Enable capacitive coupling.
42 SERDES TX Drvr Pre-Emp – Primary (5704 only) Configure
Description:
The TX driver pre-emphasis value that is used for the primary device of a 5704 if it is
enabled by option 44 below.
43 SERDES TX Drvr Pre-Emp – Secondary (5704 only) Configure
Description:
The TX driver pre-emphasis value that is used for the secondary device of a 5704 if it is
enabled by option 44 below.
44 SERDES TX Drvr Pre-Emp – ENABLE (5704 only) Configure
Description:
Enable/Disable the setup of the TX driver pre-emphasis defined in options 42 and 43
above.
Disable (0) Disable TX driver per-emphasis.
Enable (1) Enable TX driver per-emphasis.
45 Reserved. Option no longer in use. Reference
46 Encoded Hot Plug Power 1 & 2 For NIC Configure

page 66
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Description:
Encoded Hot plug power values 1 & 2 for a NIC device that is used only if enabled in
option 50 below. The following description applies to options 46-49.

This option is only valid for 5787 and 575xCx devices. The power values need to be setup
by the OEM / manufacture based on actual measurements. Default values, contained in
the bootcode / firmware, are loosely based on the in house Broadcom NIC card.

15-0 Power Budget data 1


7-0 Base Power in .1 Watt
For example, 1.4 Watt should have value 14.
9-8 PM State
00 D0
01 D1
10 D2
11 D3
12-10 Type
000 PME Aux
001 Auxiliary
010 Idle
011 Sustained
111 Maximum
13-15 Power Rail
000 12V
001 3.3V
010 1.8V
111 Thermal
31-16 Power Budget data 2
See Power Budget Data 1 for detail, Bit number add 16.
47 Encoded Hot Plug Power 3 & 4 For NIC Configure
Description:
Encoded Hot plug power values 3 & 4 for a NIC device that is used only if enabled in
option 50 below. Look at option 46 for details.
48 Encoded Hot Plug Power 5 & 6 For NIC Configure
Description:
Encoded Hot plug power values 5 & 6 for a NIC device that is used only if enabled in
option 50 below. Look at option 46 for details.
49 Encoded Hot Plug Power 7 & 8 For NIC Configure
Description:
Encoded Hot plug power values 7 & 8 for a NIC device that is used only if enabled in
option 50 below. Look at option 46 for details.
50 Hot Plug Power Configure
Description:
Enable/Disable the hot plug power values defined in options 46-49.
Disable (0) Disable hot plug power feature.

page 67
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Enable (1) Enable hot plug power feature.


51 Pri. Port SMB Address (ASF/IPMI) Configure
Description:
SMB address of the primary port on a device.
52 Sec. Port SMB Address (IPMI) Configure
Description:
SMB address of the secondary port on a device (only valid for dual port devices).
53 Cable Sense Configure
Description:
Enables a low power mode (IDDQ) of the chip which allows the presence of a cable to be
detected by the chip (valid for 5752M/5755M/5787M/5787FM devices). Once Cable Sense
is enabled GPIO3 will be an Energy Detect Output Pin and will be high if a cable (with a
signal present) is plugged into the RJ45 and low otherwise.
Disable (0) Disable cable sense.
Enable (1) Enable cable sense.
54 GPIO 0 Input/Output Config Configure
Description:
Setting GPIO 0 input/output configuration (5714 LOM, 5715 LOM 5755M LOM only)
Input (0) Config as input
Output HI (1) Config as output HI
Output LO (2) Config as output LOW

55 GPIO 2 Input/Output Config Configure


Description:
Setting GPIO 2 input/output configuration (5714 LOM, 5715 LOM 5755M LOM only)
Input (0) Config as input
Output HI (1) Config as output HI
Output LO (2) Config as output LOW
56 L1ASPM Debounce En Configure
Description:
Enable L1ASPM Debounce for PCI-E Mobile Devices only
Disable(0) Disable
Enable (1) Enable

57 Link Aware Mode Configure


Description:
Enable Link Aware Mode for Taishan, Caesar_II and Soledad Devices only
Disable(0) Disable
Enable (1) Enable

58 Link Speed Power Configure


Description:
Enable Link Speed Power for Taishan, Caesar_II and Soledad Devices only
Disable(0) Disable
Enable (1) Enable

page 68
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Example: (For Selfboot firmware).

0:>secfg
1. MAC Address.........: 001018000000
2. Device Id...........: 1693
3. Sub Vendor Id.......: 14E4
4. Sub Device Id.......: 1693
5. Wake on LAN.........: Disabled
6. WoL Speed Limit 10..: Disabled
7. LOM/NIC design......: NIC
8. Phy. Auto PowerDown.: Disabled
9. Reverse Nway........: Disabled
a. Disable PowerSaving.: Disabled
b. LED mode............: Phy1 Mode
c. Custom PCI power....: Yes (comsumed D0:100.D3:10 dissipated D0:100.D3:10)
d. Custom PCIE power...: Yes (3.3v, Sustained, D0, 1.2 Watt...)
e. Custom VPD-R Data...: Yes
g. Cable Sense/Low Power Energy Detect .....: Disabled
h. MBA CFG Data
i. User Defined Data…...: No
j. Link Aware Mode……: Enabled
k. Link Speed Power……: Enabled

x. Save & exit

----------------------------------------------- LED Mode (option b)-----------------------------------------_


-> b

Selfboot LED Mode selection

0. Mac Mode
1. Phy1 Mode
2. Phy2 Mode
3. Shared Traffic/Lik LED Mode
4. Shasta MAC mode
5. Wireless Combo Mode

----------------------------------------------- Custom PCI power (option c)----------------------------------------

-> c

Selfboot PCI Power Consumption/Dissipate value

1. Use system default


2. Costom define

-> 2
D0 State Power Comsumed decimal value (0-255) (100)->100
D3 State Power Comsumed decimal value (0-255) (10)->10
D0 State Power Dissipated decimal value (0-255) (100)->100

page 69
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

D3 State Power Dissipated decimal value (0-255) (10)->10

-------------------------------------------- Custom PCIE power (option d)----------------------------------------


-> d

Selfboot PCIE Power Budgeting Data

1. Use system default


2. Costom define

-> 2

0. Data0: 3.3v, Sustained, D0, 1.2 Watt


1. Data1: 3.3v, Maximum, D0, 1.4 Watt
2. Data2: 3.3v, Maximum, D3, 0.6 Watt
3. Data3: 3.3v, PME Aux, D3, 0.4 Watt
4. Data4: Unused
5. Data5: Unused
6. Data6: Unused
7. Data7: Unused

-------------------------------------- Custom VPD [Link] (option e)----------------------------------------


-> e
Selfboot VPD R

1. Use system default


2. Costom define

-> 2
1. Part Number : BCM957xx
2. Engineering Change : 106679-15
3. Serial Number : 0123456789
4. Manufacturing ID : 14e4
5. Read only VPD Vendor Specific Data (V0) :
6. Product Name :

Description of above parameters:

To enter the ‘secfg’ menu shown above a user type in ‘secfg’ for selfboot firmware at the
diagnostics command line. A menu is present to the user showing the ‘secfg’ options shown
above. A user can change the ‘secfg’ parameter by entering the option number.

The tables below provide details for each parameter of the ‘secfg’ options for selfboot
firmware. The top right of each table has the word “Configure” or “Reference”.
“Configure” signifies that the option is used to configure the operating characteristics of
the device or default values of registers in the device. “Reference” signifies that the option
is use for display purposes and does not affect the operating characteristics of the device or

page 70
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

default values of registers in the device.

1 MAC Address Configure


Description:
MAC address of the device.
2 Device ID Configure
Description:
PCI Device ID.
3 Subsystem Vendor ID Configure
Description:
PCI Subsystem PCI Vendor ID.
4 Subsystem Device ID Configure
Description:
PCI Subsystem PCI Device ID.
5 Magic Packet WoL Configure
Description:
A system can be configured to power-on when a Magic Packet is received.
Enable(1) The device will assert the pme signal, to power on the system, when a
magic packet is received.
Disable(2) Magic packets are ignored.
Note:
A driver can setup the WoL behavior of a device and the value programmed into this
location is ignored.
6 Limit WoL Speed to 10 Configure
Description:
Limit Wake on LAN (WoL) line speed.
No(0) 10 or100 Mbits/s is used for WoL.
Yes(1) Only 10 Mbits/s is used for WoL.
7 Design Type Configure
Description:
Select NIC or LOM based Ethernet controller.
NIC(0) Option selected for a plug in network interface card.
LOM(1) Option selected for a LAN on motherboard.
Note:
The firmware and the drivers use this to determine the operational characteristics of a
device. For example, on a LOM GPIO2 is tied to the SEEPROM write protect pin and on a
NIC GPIO 1 and 2 is used to switch between main and auxiliary power for wake on LAN
functionality.
8 Enable PHY Auto Powerdown Configure
Description:
Enable GPHY auto-power down when there is no link present (to conserver power).
No(0) The PHY will not auto power down.
Yes(1) The PHY will auto power down when there is no link.
9 Reversed Nway Configure
Description:
Nway Negotiation.
0 (default) Auto-negotiation is done from 1000->100->10 Mbits/s.
1 Auto-negotiation is done from 10->100->1000 Mbits/s.

page 71
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Note:
A user could set the chip for option 1 when running a laptop on battery power. The chip
would auto-negotiate starting at a lower speed and lower power. The chip would only go to
higher line rates and higher power if the lower line rates were unavailable.

a Disable Power Saving capability Configure


Description:
Disable Power Saving capability setup by option 33 above. When disable a device will use
Nway negotiation.
No(0) Power-saving capability active.
Yes(1) Power-saving capability inactive.
b Led Mode Configure
Description:
A device can be configured to use one LED to indicate speed and activity or three LEDs.
Use a devices data sheet to verify the LED modes supported by a devices and for
exceptions to the LED modes described below.
Mac Mode (0) The LEDs are controlled by the value in the Mac LED Control Register.
Phy Mode1 (1) Three LEDs are used for 10/100/1000 Mbits/s and each is driven
individually by the device.
Phy Mode2 (2) One LED is used for 10/100/1000 Mbits/s and is connected as described
below.

5700/01 – The Link10 line will indicate link for all speeds. Link100 and
Link1000 will encode the line speed as show in the following table:
Link 100 Link 1000 Speed
0 0 10 Mbits/s
1 0 100 Mbits/s
0 1 1000 Mbits/s

For all other 57xx devices the three link lines operate in an open drain
configuration and can be tied together with a pull up resistor to control a
LED.
SharedTraffic Mode specific to the 575x and 572x chips. The link LED performs a dual
(3) role: solid when there is a link and blinks when there is activity.
Shasta Mac Mode specific to the 575x and 572x chips. The link LED blinks only when
Mode (4) traffic is for Shasta.
Wireless Mode specific to the 575x and 572x chips. When link is lost the LEDs are
Combo (5) driven by inputs pins that are connected to the LED signals of a wireless
link.
c Custom PCI Power Reference
Description:
Self boot PCI Power Consumption/Dissipate for D0 and D3 state.
d Custom PCIE Power Reference
Description:
Self boot PCIE Power Budgeting Data

e-1 Part Number Reference


Description:
VPD part number..
e-2 Engineering Change Reference
Description:
VPD engineering change.

page 72
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

e-3 Serial Number Reference


Description:
VPD serial number.
e-4 Manufacturing ID Reference
Description:
VPD manufacturing ID.
e-5 Read only VPD Vendor Specific Data (V0) Reference
Description:
VPD V0 value. Data field provided for the customer.

e-6 Product Name Reference


Description:
VPD Product description string.

g Cable Sense Configure


Description:
Enables a low power mode (IDDQ) of the chip which allows the presence of a cable to be
detected by the chip (valid for 5752M/5755M/5787M/5787FM devices). Once Cable Sense
is enabled GPIO3 will be an Energy Detect Output Pin and will be high if a cable (with a
signal present) is plugged into the RJ45 and low otherwise.
Disable (0) Disable cable sense.
Enable (1) Enable cable sense.

h MBA Configuration Configure


Description:
MBA Configuration
VLan Enable (1) Enabled / Disabled
VLan ID (2) VLan ID
MBA Hide Banner (3) Enabled / Disabled
MBA Hot Key (4) Ctrl-B / Ctrl-S
MBA Protocol (5) PXE / RPL / BOOTP / ISCSI
MBA Config Timeout (6) MBA Config Timeout value
MBA Bootstrap (7) Auto / BBS / INT18 / INT19
MBA Link Speed (8) Auto /10HD / 10FD / 100HD / 100FD
Remove MBA Config (9) 0: No 1:Yes

Example: (For Hardware Selfboot firmware).

0:>secfg
1. MAC Address.........: 001018123456
2. Device Id...........: 1713
3. Sub Vendor Id.......: 14E4
4. Sub Device Id.......: 9713
5. WOL.................: Disabled
6. WOL Speed Limit 10..: Disabled
7. WOL Auto............: Disabled

page 73
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

8. LED mode............: PHY MODE 2


9. VPD [Link] and VPD-R Data: Yes
A. Super-airplane Mode: Enabled
B. MBA Configuration
C. NIC Design………: NIC
D. L1 PLL Disable …... No
E. Clkreq………………: Yes
F. PCIE Link Polarity Fix Disable: Yes (5906 A2 only)
G. L1ASPM Debounce Enable: Disable (5906M only)

x. Save & exit

----------------------------------------------- WOL Auto (option 7)-----------------------------------------_

-> 7

HW Selfboot Driver WOL selection

0. Disable
1. Magic Packet WOL Enable

----------------------------------------------- LED Mode (option 8)-----------------------------------------_

-> 8

HW Selfboot LED Mode selection

0. Mac Mode
1. Phy1 Mode
2. Phy2 Mode
3. Shared Traffic/Lik LED Mode

----------------------------------------------- VPD Data (option 9)-----------------------------------------_


-> 9

HW Selfboot VPD Data


1. Part Number : BCM95906
2. Engineering Change : 106679-15
3. Serial Number : 0123456789
4. Manufacturing ID : 14e4
5. Read only VPD Vendor Specific Data (V0) :
6. Product Name : Broadcom NetLink Fast Ethernet Controller

x. Save & exit

----------------------------------------------- MBA Configuration (option B)----------------------------------------

-> B

HW Selfboot MBA Data


1. VLAN Enable : Disabled

page 74
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

2. VLAN ID :0
3. MBA HIDE BANNER : Disabled
4. MBA HOT KEY : Ctrl-B
5. MBA PROTOCOL : PXE
6. MBA CONFIG TIME OUT :0
7. MBA BOOTSTRAP : AUTO
8. MBA LINK SPEED : AUTO

x. Save & exit

Description of above parameters:

To enter the ‘secfg’ menu shown above a user type in ‘secfg’ for hardware selfboot
firmware at the diagnostics command line. A menu is present to the user showing the
‘secfg’ options shown above. A user can change the ‘secfg’ parameter by entering the
option number.

The tables below provide details for each parameter of the ‘secfg’ options for hardware
selfboot firmware. The top right of each table has the word “Configure” or “Reference”.
“Configure” signifies that the option is used to configure the operating characteristics of
the device or default values of registers in the device. “Reference” signifies that the option
is use for display purposes and does not affect the operating characteristics of the device or
default values of registers in the device.

1 MAC Address Configure


Description:
MAC address of the device.
2 Device ID Configure
Description:
PCI Device ID.
3 Subsystem Vendor ID Configure
Description:
PCI Subsystem PCI Vendor ID.
4 Subsystem Device ID Configure
Description:
PCI Subsystem PCI Device ID.
5 WoL Configure
Description:
A system can be configured to power-on when a Magic Packet is received.
Enable The device will assert the pme signal, to power on the system, when a
magic packet is received.
Disable Magic packets are ignored.
Note:
A driver can setup the WoL behavior of a device and the value programmed into this
location is ignored.
6 Limit WoL Speed to 10 Configure

page 75
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Description:
Limit Wake on LAN (WoL) line speed.
No 10 or100 Mbits/s is used for WoL.
Yes Only 10 Mbits/s is used for WoL.
7 Wol Auto Setting Configure
Description:
Select WOL Auto Setting
Disable (0) WOL is Disabled
Magic Packet Option selected for Magic Packet WOL.
WOL (1)
8 Led Mode Configure
Description:
A device can be configured to use one LED to indicate speed and activity or three LEDs.
Use a devices data sheet to verify the LED modes supported by a devices and for
exceptions to the LED modes described below.
Mac Mode (0) The LEDs are controlled by the value in the Mac LED Control Register.
Phy Mode1 (1) Dual Link LED configuration. Two LEDs are used to indicate 10/100
Mbps.
Phy Mode2 (2)
Link/Speed LED configuration. One LED is used to indicate link status
of all 10/100 Mbps.
SharedTraffic (3) Shared Traffic/Link LED Mode. The Link LED performs dual role: Solid
Green, when Link up. Blink when there is an activity.

9 VPD Data Configure


Description:
VPD Product Name and Read Data.
Part Number (1) VPD Part Number
Engineering Change (2) VPD Engineering Change
Serial Number (3) VPD Serial Number
Manufacturing ID (4) VPD Manufacturing ID
Read only VPD Data (5) VPD Read only V0 Data
Product Name (6) VPD Product Name

A Super Airplane Mode Configure


Description:
Super Airplane mode
Disable Disable Super Airplane Mode
Enable Enable Super Airplane Mode
B MBA Configuration Configure
Description:
MBA Configuration
VLan Enable (1) Enabled / Disabled
VLan ID (2) VLan ID
MBA Hide Banner (3) Enabled / Disabled
MBA Hot Key (4) Ctrl-B / Ctrl-S
MBA Protocol (5) PXE / RPL / BOOTP / ISCSI
MBA Config Timeout (6) MBA Config Timeout value
MBA Bootstrap (7) Auto / BBS / INT18 / INT19
MBA Link Speed (8) Auto /10HD / 10FD / 100HD / 100FD

page 76
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

C Design Type Configure


Description:
Select NIC or LOM based Ethernet controller.
NIC(1) Option selected for a plug in network interface card.
LOM(0) Option selected for a LAN on motherboard.

D L1 PLL Powerdown Disable Configure


Description:
Disable / Enable L1 PLL Powerdown
Disable(0) Disable L1 PLL Powerdown
Enable(1) Enable L1 PLL Powerdown

E Clock Request Configure


Description:
Disable / Enable Clock Request
Disable(0) Disable Clock Request
Enable(1) Enable Clock Request

10.8 seprg
Command: seprg

Description: Program NVRAM and management firmware

Syntax: seprg <file_name>

Input file need to be found in the same location as [Link].

Options:

-d Do not perform device check

-f<string> filename

-l<HEX> length in bytes (Default = size of input file)

-m Do not restore original MAC address

-n Do not restore all original data at Configuration Block in OTP

-o<HEX> offset of serial nvram (def=00000000)

-s Do not restore original Serial Number

-a Program ASF/management firmware

-b As APE UPDATE entry (for –a with APE)

page 77
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-k<DEC> pad to kilobytes (for –a with APE)

-u Program UMP firmware

-c Skip image CRC check

-p Restore NVRAM Config data between Bootcode and Selfboot


fw *

Example:

1. Program NVRAM with contents of input file [Link]


0:> seprg [Link]

0:>seprg [Link] -a

2. Program NVRAM with APE DASH firmware [Link] and pad up to 300kilo bytes.
0:>seprg –a –k300 [Link]

3. Program NVRAM with APE DASH firmware [Link] as APE UPDATE image
and pad up to 300kilo bytes. Padding and backup image is needed to enable out-of-band
DASH firmware update.

0:>seprg –a –b –k300 [Link]

*-p option will restore NVRAM configuration data between Bootcode and selfboot
firmware. The configuration data that will be restored are listed below.

a. Wol_enable

b. Wol_Limit_10

c. Driver_wol_enable

d. Lom_design

e. Phy_auto_power_down

f. Reverse_nway

g. Disable_power_saving

h. Phy_led_mode

i. Shasta_ext_led_mode

j. Cable_sense

page 78
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.9 upgfrm
Command: upgfrm

Description: Upgrade ISCSI, PXE, Boot Code and Selfboot Firmware from a File. This
command reads code from a file and program into iscsi, pxe or boot area. Both parameter,
the programming target '-p', 'b' or '-i' and filename, must be specified. In case of ISCSI
firmware, ISCSI Boot Firmware will be updated by default. ISCSI CFG Block will only be
updated if there is no ISCSI CFG Block present in NVRAM. ISCSI CFG Program will
NOT be programmed by this command. In case of Selfboot Firmware, this command will
support Format 0 to Format 1 and Format1 to Format1 update. Format0 to Format0 and
Format1 to Format0 update are NOT supported by this command. User will need to use
“seprg” command. For legacy bootcode, only VPD data block and Phase 1 and Phase 2
bootcode will be updated by default. If –v is entered, only Phase 1 and Phase 2 bootcode
will be updated. For Selfboot firmware and Hardware Selfboot firmware, only patches will
be updated.

Syntax: upgfrm <p | b | I| v> filename

upgfrm [-f<filename>] [-b | -p | -i] | [-d] | [-v]

Options:

-b Upgrade boot code/Selfboot firmware

-d Do not perform device check

-f<string> Input file

-p Upgrade PXE code

-i Upgrade ISCSI code

-r Do not perform chip rev. check for Selfboot

-n Set PFN when loading LOM PXE code

-v Preserve VPD block data in legacy bootcode upgrade

10.10 sever
Command: sever

Description: Display Serial NVRAM Version

Syntax: sever

page 79
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.11 sechksum
Command: sechksum

Description: Check/Update Serial NVRAM checksum

Syntax: sechksum

Options:

-v<DEC> verbose level (0,1) (def=1)

10.12 sedump
Command: sedump

Description: Dump NVRAM content to a file. The value stored at location 0xC in the
NVRAM is the starting address of the code that the chip loads and executes. The code
starting address is 0x200 for NVRAM pages aligned on 256 byte boundaries and 0x2F8 for
the Atmel device that has a NVRAM page size of 264. If “sedump” is used to generate an
image file for a NVRAM/EEPROM burner then “-a” should be used, for an Atmel device,
if one wants to preserve the 0x2F8 code starting address that is automatically translated to
0x200 by software without the “-a” option. More details can be found in application note
570X-AN700-R.

Syntax: sedump -f<string> [Len]

Options:

-a<string> no Atmel Flash address translation

-f<string> string is the filename

-l<DEC> length in decimal, use 0 for entire NVRAM image (def=8192)

-s skip crc checking for legacy bootcode

10.13 asfcfg
Command: asfcfg

Description: Configure ASF in NVRAM

Syntax: asfcfg [filename]

If [filename] is provided the file is used to configure the ASF configuration information in
NVRAM. If asfcfg is entered by it self a menu is present the user and the options of the
items listed in the menu are described below.
0 Save to file

page 80
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Description:
Use this menu option save the network adapter's ASF configuration table to a binary file.
1 ASF Settings
Description:
Provides the sub menu with the options described below.
0 Return to previous menu.
1 Enable/Disable Remote Management Control Protocol (RCMP)
2 Enable/Disable the transmission of Platform Event Trap (PET)
messages.
3 Enable/Disable transmission of periodic system heartbeat messages.
4 Interval in seconds between transmitted heartbeat messages.
5 PET messages (except the system heartbeat) are retransmitted three
times. This entry allows the user to specify, in seconds, the interval of
time between these transmissions.
6 Client IP address used for communication.
7 Management console IP address to which communication is directed.
8 Gateway IP address used when client and management console are on
different subnets.
9 Subnet mask used to determine client and management console
subnets.
10 Configures link speed for ASF operation when the OS is not present.
11 Unique value used to by ASF. Usually setup by an OS based
configuration utility, based on the SMBIOS system information structure.
12 Configure the polling interval, in seconds, which legacy SMBus devices
are monitored (such as the chassis intrusion sensor).
13 Specifies, in seconds, the amount of time to wait before polling the first
legacy SMBus device.
14 Send 'ASD Ready' SMBus Msg
15 Enable/Disable the system to wake up from a low power states when the
system receives ASF or RMCP traffic.
16 Feature is not currently supported.
17 SNMP community name.

2 ASF Alert Info


3 ASF Alert Data for Legacy Devices
4 ASF Remote Control Data
5 ASF Capabilities Supported
6 ASF SMBus Addresses

page 81
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Description:
These menu options may be used to override values in the network adapter's ASF
Configuration Table that correlate to the following records in the system's "ASF! Description
Table":

ASF_INFO
ASF_ALRT
ASF_RCTL
ASF_RMCP
ASF_ADDR

The values in these records are normally copied from the system's "ASF! Description
Table" (using the ACPI System Description Table architecture) into the ASF Configuration
Table in the network adapter's non-volatile memory by the Broadcom ASF Configuration
Utility (ASFConfig). See the Alert Standard Format (ASF) Specification v2.0 for detailed
descriptions of these records.

7 Reserved
Description:
Reserved

8 SMBus Init Data


Description:
Not to be used by customers. For Broadcom internal use only.

9 Save and Exit


Description:
Saves the modified ASF Configuration Table to the network adapter's non-volatile memory
and exists.

10 Exit without Saving


Description:
Exits without saving any changes to the ASF Configuration Table.

10.14 mancfg
Command: mancfg

Description: Configure management firmware in NVRAM. For device without APE, this
command is same as asfcfg command.

Syntax: mancfg [-d | -a | -s | -i filename | -e filename]

Options:

-d Verbose description of content of APE_CFG

-a Import ASF_SDT record from host PC memory

-s Import SMBIOS record from host PC memory

-i Import APE_CFG from file instead of NVRAM

page 82
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-e Export APE_CFG to specified file

Note: mancfg command can be run in command mode or interactive mode. When option is
specified, command mode is used. For details of interactive mode, please refer to bmcfg,
and mancfg documentation. This command is work in progress, will be updated later.

10.15 asfmbox
Command: asfmbox

Description: Create ASF Off-Line Mailboxes in NVRAM.

Syntax: asfmbox [-c | -v | -d | -t]

Options:

-c Create specified number of ASF Mailboxes

-v View status of all ASF Mailboxes

-d Dump contents of specified ASF Mailbox

-t Test ASF Mailbox NVRAM block

10.16 flshmode
Command: flshmode

Description: Configure ASF in NVRAM

Syntax: flshmode [auto | passthru | legacy | new]

10.17 flshread
Command: flshread

Description: Same as seread

Syntax: flshread start[-end | len]

10.18 chkpxe
Command: chkpxe

Description: Check PXE code image

Syntax: chkpxe <filename>

page 83
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.19 dir
Command: dir

Description: display file directory in NVRAM

Syntax: dir

10.20 erase
Command: erase

Description: erase file from directory in NVRAM

Syntax: erase <entry> | all

Options:

-y do not ask for conformation

10.21 pxeprg
Command: pxeprg

Description: Program PXE firmware into NVRAM. This command reads PXE code from a
file and program into NVRAM

Syntax: pxeprg <filename>

10.22 flshdev
Command: flshdev

Description: Select flash device to access

Syntax: flshdev seeprom | atmelflash | sstflash

10.23 bitbang
Command: bitbang

Description: Generate bitbang pattern to seeprom bus. Enter hex numbers to be written to
seeprom bus. For serial eeprom, use 's' for start, 'p' for stop condition, 'x' with '1..9' specifies
how many residual bits to send. For flash, use 's' for chipSelect, 'p' for cancel chipSelect 'r'
with a number specifies how many bytes to read.

Syntax: bitbang <data>

page 84
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.24 seclock
Command: seclock

Description: set NVRAM config1 content value after reset.

Syntax: seclock <32bitNewValue>

10.25 setorture
Command: setorture

Description: NVRAM reset torture test

Syntax: setorture

Options:

-c Continue on Error

-i<DEC> Initial Delay in ms (def=0)

-m<DEC> Maximum Delay in ms (def=3000)

-n<DEC> iteration (def=1)

-p Power reset

-r Random delay

-s<DEC> Delay incremental time (us) (def=1)

10.26 seinit
Command: seinit

Description: Initialize NVRAM block.

Syntax: seinit

Options:

-i<DEC> do not restore NVRAM clock default value (def=0)

10.27 searb
Command: searb

Description: set/report current NVRAM arbitration bit. Valid arbitraion number is 0..3.

page 85
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Syntax: searb [n]

10.28 seprotect
Command: seprotect

Description: set gpio pin for NVRAM write protect. Use 'none' to disable write protect
feature.

Syntax: seprotect [0|1|2|none]

10.29 selclock
Command: selclock

Description: set Legacy EEPROM clock value (bit 16-24 of EEPROM addr reg)

Syntax: selclock <8bitNewValue>

10.30 semap
Command: semap

Description: Display NVRAM usage

Syntax: semap

10.31 setwol
Command: setwol

Description: Enable/Disable WOL

Syntax: setwol [e/d]

Options:

-d Disable WOL

-e Enable WOL

10.32 setpxe
Command: setpxe

Description: Enable/Disable PXE

Syntax: setpxe

page 86
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Options:

-d Disable PXE

-e Enable PXE

-s<DEC> Specify PXE Speed (def=0), 0. auto, 1. 10HD, 2. 10FD, 3.


100HD, 4. 100FD

10.33 setasf
Command: setasf

Description: Enable/Disable ASF

Syntax: setasf

Options:

-d Disable ASF

-e Enable ASF

10.34 secomp
Command: secomp

Description: compare eeprom content against the file

Syntax: secomp

Options:

-c continue on error

-f<string> filename

-l<HEX> length (def=00000000)

-o<HEX> offset (def=00000000)

10.35 dreset
Command: dreset

Description: double reset test for EEPROM debug

Syntax: dreset

page 87
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.36 userblock
Command: userblock

Description: create a userblock in NVRAM

Syntax: userblock

10.37 setmba
Command: setmba

Description: Enable Multiple Boot Agent

Syntax: setmba

Options:

-d Disable MBA

-e<DEC> Enable MBA Protocol (def=0), 0. PXE, 1. RPL, 2. BOOTP

-s<DEC> Specify MBA Speed (def=0), 0. auto, 1. 10HD, 2. 10FD, 3.


100HD, 4. 100FD

10.38 segencrc
Command: segencrc

Description: Append a CRC to the specified block

Syntax: segencrc <start-end> | <start length>

10.39 secfg1
Command: secfg1

Description: Configure NVRAM Group 1

Syntax: secfg1

Options:

-m Mac address xx:xx:xx:xx:xx:xx

-r Power Dissipated [Link]

-c Power Consumed [Link]

-v Vendor ID

page 88
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-d Vendor Device ID

-s SubSystem Vendor ID

-i SubSystem Device ID

-p PXE 1:Enable 2:Disable

-x PXE SP 0:Auto 1:10HD 2:10FD 3:100HD 4:100FD 6:1000FD


(TBI)

-w Magic Packet WOL 1:Enable 2:Disable

10.40 secfg2
Command: secfg2

Description: Configure NVRAM Group 2

Syntax: secfg2

Options:

-p Product Name

-n Part Number

-e Engineering Change

-s Serial Number

-m Manufacturing ID

-a Asset Tag

-r Part Rev

-v Voltage

-f Force PCI Mode 1:Enable 2:Disable

10.41 secfg3
Command: secfg3

Description: Configure NVRAM Group 3

Syntax: secfg3

page 89
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Options:

-l Led Mode 0:Mac 1:Phy1 2:Phy2 3:S Traffic 4:Shasta Mac 5:Wireless Combo

-r Max PCI Retry 0-7, 8:Auto

-a ASF 1:Enable 2:Disable

-d Dual Mac 0:Norm 1:MacB 2:MacA 3:XBAR 4:Swap 7:SwapXBAE

-m MBA Boot Protocol 0:PXE 1:RPL 2:BOOTP

-b MBA Bootstrap Type 0:Auto 1:BBS 2:Int18 3:Int19

-t MBA Delay Time 0-15

-e Exp ROM 0:64K 1:128K 2:256K 3:512K 4:1M 5:2M 6:4M 7:8M 8:16M

-n Design Type 0:NIC 1:LOM

-m MBA Boot Protocol 0:PXE 1:RPL 2:BOOTP 3:ISCSI

10.42 secfg4
Command: secfg4

Description: Configure NVRAM Group 4

Syntax: secfg4

Options:

-v Read VPD Vendor Data V0

-w Read/Write VPD Vendor Data V1

-n Reversed Nway 0:No 1:Yes

-s Limit WOL Speed to 10 0:No 1:Yes

-f Fiber WOL Capable 0:No 1:Yes

-c Clock-Run 0:Disable 1:Enable

-p Enable Phy Auto Power Down 0:No 1:Yes

-d Disable Power Saving 0:No 1:Yes

-h Hide MBA Setup Prompt 0:Disable 1:Enable

page 90
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-k MBA Setup Hot Key 0:Ctrl-S 1:Ctrl-B

-i Capacitive Coupling 0:Disable 1:Enable

10.43 secfg5
Command: secfg5

Description: Configure NVRAM Group 5

Syntax: secfg5

Options:

-i Capacitive Coupling 0:Dis 1:En

-e SERDES Tx Drvr Pre-Emp - Primary

-t SERDES Tx Drvr Pre-Emp - Secondary

-z SERDES Tx Drvr Pre-Emp - ENABLE

-u Encoded Hot Plug Power Value 1 & 2 For NIC

-d Encoded Hot Plug Power Value 3 & 4 For NIC

-r Encoded Hot Plug Power Value 5 & 6 For NIC

-q Encoded Hot Plug Power Value 7 & 8 For NIC

-h Hot Plug Power For NIC - Enable

-a ASF/IPMI SMB Address for Pri. Port

-b IPMI SMB Address for Sec. Port

-c Cable Sense - Enable

-x GPIO 0 Config 0:Input 1:OutputH 2: OutputL (5714LOM and 5715 LOM only)

-y GPIO 2 Config 0:Input 1:OutputH 2: OutputL (5714LOM and 5715 LOM only)

-f L1ASPM_Debounce_En 0:Dis 1:En (PCIE Mobile devices only)

10.44 setipmi
Command: setipmi

Description: Enable/Disable IPMI

page 91
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Syntax: setipmi

Options:

-d Disable IPMI

-e Enable IPMI

10.45 loadfw
Command: loadfw

Description: Load Firmware to Tx/RX CPUs

Syntax: loadfw

Options:

-b<HEX> set breakpoint (0=off) (def=00000000)

-d<HEX> data pattern to be used for memory init. (def=00000000)

-f<string> filename (for bcmediag compatibility)

-I don't initialize memory before loading, def=yes

-m don't turn on CPU Trace (def=on)

-s don't start cpu

-t load to tx cpu, def=rxpcu

-v disable verbose

10.46 cpudtt
Command: cpudtt

Description: Read and display TX CPU trace (not valid for 5705)

Syntax: cpudtt <begin_addr>[- end_addr | num_bytes ]

Address range: 0x00 – 0x80

Example:

1. Read and display TX CPU trace from location 0x00 to 0x04.


0:> cpudtt 0-5
000 t0000002f c0000000 00000000 00000000 00000000 00000000

page 92
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

001 t00000000 00000000 00000000 00000000 00000000 00000000


002 t00000000 00000000 00000000 00000000 00000000 00000000
003 t00000000 00000000 00000000 00000000 00000000 00000000
004 t00000000 00000000 00000000 00000000 00000000 00000000

2. Read and display 4 locations of TX CPU trace from start from location 0x00.
0:> cpudtt 0 5
000 MainCpuB t0000002f c0000000 00000000 00000000 00000000 00000000
001 t00000000 00000000 00000000 00000000 00000000 00000000
002 t00000000 00000000 00000000 00000000 00000000 00000000
003 t00000000 00000000 00000000 00000000 00000000 00000000

10.47 cpudrt
Command: cpudrt

Description: Read and display RX CPU trace (not valid for 5705)

Syntax: cpudrt <begin_addr>[- end_addr | num_bytes]

Address range: 0x00 – 0x80

Example:

1. Read and display RX CPU trace from location 0x00 to 0x04.


0:> cpudrt 0-5
000 MainCpuA t00000030 164414e4 e1000004 00000000 164414e4 00000000
001 *BUpCpuA t00000032 00000000 08000034 00440400 00001c40 00000000
002 *BUpCpuA t00000001 00000001 08000034 00440000 00000000 00000000
003 t00000000 00000000 00000000 00000000 00000000 00000000
004 t00000000 00000000 00000000 00000000 00000000 00000000

2. Read and display 4 locations of RX CPU trace from start from location 0x00.
0:> cpudrt 0 5
000 t00000030 164414e4 e1000004 00000000 164414e4 00000000
001 t00000032 00000000 08000034 00440400 00001c40 00000000
002 t00000001 00000001 08000034 00440000 00000000 00000000
003 t00000000 00000000 00000000 00000000 00000000 00000000

10.48 cputrace
Command: cputrace

Description: toggles cpu trace mode

Syntax: cputrace [1|0]

10.49 haltcpu
Command: haltcpu

Description: Halt CPU

Syntax: haltcpu

page 93
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.50 loadbootcode
Command: loadbootcode

Description: execute bootcode from file instead of NVRAM

Syntax: loadbootcode <filename>

Options:

-d<HEX> data pattern to be used for memory init. (def=00000000)

-f<string> filename

-i don't initialize memory before loading, def=yes

-m don't turn on CPU Trace (def=on)

-s don't start cpu

-t load to tx cpu, def=rxpcu

-v disable verbose

10.51 disasm
Command: disasm

Description: Disassemble MIP instructions

Syntax: disasm [address [line]]

10.52 step
Command: step

Description: Step MIP instructions

Syntax: step

10.53 go
Command: go

Description: start CPU

Syntax: go

page 94
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.54 showgpr
Command: showgpr

Description: toggles showing cpu gpr mode

Syntax: showgpr 1|0

10.55 pc
Command: pc

Description: set current CPU program counter

Syntax: pc

10.56 breakpoint
Command: breakpoint

Description: set current CPU breakpoint

Syntax: breakpoint

10.57 select
Command: select

Description: select current CPU

Syntax: select <r|t>

10.58 u
Command: u

Description: Alias of disasm command

Syntax: u [address [line]]

10.59 trap
Command: trap

Description: trap cpu memory

Syntax: trap <low> <high> | off

page 95
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.60 cpuinfo
Command: cpuinfo

Description: display cpu information

Syntax: cpuinfo [r|t]

10.61 cpugprstatus
Command: cpugprstatus

Description: Display internal CPU GPR test status

Syntax: cpugprstatus

10.62 cpugprrestart
Command: cpugprrestart

Description: Restart internal CPU GPR test

Syntax: cpugprrestart

10.63 cpufetch
Command: cpufetch

Description: Test CPU Instruction fetch logic with 1.1V and 1.3 V setting

Syntax: cpufetch

10.64 romcodetest
Command: romcodetest

Description: execute ROM Code Test

Syntax: romcodetest

Options:

-f<string> filename

-i<HEX> iteration (def=00000001)

-v verbose

page 96
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.65 apeinfo
Command: apeinfo

Description: Display APE CPU related info. When no option is given, displays memory
usage for each Nucleus tasks and memory pool. Only one option can be specified at a time,
information related to specified option will be displayed.

Syntax: apeinfo

Options:

-c Show APE CPMU related info

-s1/s2 Show APE SMBus block 1 or 2 info

-r Show APE control registers

-f Show receive management filters

-m Show APE mutex and shared memory info

10.66 apectl
Command: apectl

Description: The command is used to control the Application Processor Engine (APE) and
its firmware (in applicable devices, e.g. BCM5761). Used for debugging. One event
option has to be specified.

Syntax: apectl

Options:

-n send APE NOP event (are you alive?)

-r send APE reset event (graceful)

-f<HEX> turn rx mgmt filter all(-f2)/on(-f1)/off(-f0)

-w<HEX> set WFI mode sleep(-w1),off(-w0),deepsleep(-w2)

-t set APE date/time

-e<HEX> send APE custom event ddeess (dd=data, ee=event id, ss=source)

-R reset APE block (ungraceful)

-C reset APE CPU (ungraceful)

page 97
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-h halt APE (graceful)

-u un-halt APE

-H halt (hold in reset) APE CPU (ungraceful)

-K kick start APE (A0 workaround)

Log Control:

-a operate on Audit Log instead of Event Log

-l<string> add log entry (text only)

-c clear log

Note:”apectl –r” can be used to restart APE manually when firmware or config changes.

10.67 apeping
Command: apeping

Description: Send APE event to ping host from APE. The host can be IPv4, IPv6 address
or host name for a DNS lookup.

Syntax: apeping <host>

10.68 aperead
Command: aperead

Description: Read APE local view data thru APE.

Syntax: apectl start[-end | len]

10.69 apeotpkey
Command: apeotpkey

Description: S

Syntax: apeotpkey

10.70 apelog
Command: apelog

Description: The command is used to create, query, and control the APE Logs in
NVRAM(in applicable devices, e.g. BCM5761)

page 98
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Option:

-a operate on Audit Log instead of Event Log

-c<DEC> create NVRAM storage for log (of specified length) (def=3232)

-q query log status

-v view log records (in hex format)

-i view log records (in decoded format)

-d dump log storage (in Byte/ASCII format)

-l<string> add log entry (text only)

-C clear log

10.71 dmaw
Command: dmaw

Description: DMA from NIC to Host Memory

Syntax; dmaw

Options:

-3 Force to use 32-bit bus

-4 Allocate 4k-aligned buffers

-a<HEX> NIC address to DMA data from (def=00000000)

-b byte swap

-c Continousely dma data

-d<HEX> delay poll dma done polling (def=00000000)

-f<string> filename

-h Use high priority DMA Write

-l<HEX> Length of DATA in bytes to DMA (def=00000100)

-n<DEC> iteration

-o<HEX> Buffer offset (def=00000000)

page 99
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-p<HEX> Pattern of Data. 0 - byte increment ; 1- byte decrement


2 - FF's ; 3 - 00's ; 4- AA 55 ... ; 5 - 55 AA ...
6 - FFFFFFFF 000000000 FFFFFFFF 00000000
7 - FFFFFFFFFFFFFFFF 0000000000000000
FFFFFFFFFFFFFFFF
8 - FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF 0000000000000...
9 - 00000000000000000000000000000000 FFFFFFFFFFFFF...
a - Word Increment ; b - Dword Increment
c - Word Decrement ; d - Dword Decrement
e - ffffffff00000000 00000000ffffffbf
f - 00000000ffffffff ffffffbf00000000
10 - 64-bit-pattern 0000000000000000 64-bit-pattern ...
11 - 64-bit-pattern ffffffffffffffff 64-bit-pattern ... (def=00000000)

-q<HEX> low 32-bit of 64-bit pattern (def=FFFFFFFF)

-v<DEC> Verbose (1..2) (def=2)

-w word swap

-x<HEX> high 32-bit of 64-bit pattern (def=FFFFFFFF)

-K<HEX> DMA write to absolute address and hang the system


(def=00000000)

Example:

1. Setup DMA NIC Memory to HOST memory. Using low priority DMA Read and
disable byte swap and enable detail display.
1:> dmaw -a=0 -l=10
Device 1
Host Address : 0x0068bb38
NIC Address : 0x00000000
Length : 0x0010
Priority : Low
Byte Swap : No
Word Swap : No

Dev 1: DMA SRAM 00000000 to Host 0068BB38

10.72 dmar
Command: dmar

Description: DMA from Host to NIC Memory

Syntax: dmar

Options:

page 100
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-w word swap

-3 Force to use 32-bit

-4 Allocate 4k-aligned buffers

-a<HEX> NIC address to DMA data to (def=00000000)

-b Byte Swap

-c Continousely dma

-d<HEX> delay poll dma done polling (def=00000000)

-f<string> File name of file that contains <length,patterns ....>

-h Use high priority DMA Read

-l<HEX> Length of DATA to do DMA (def=00000100)

-n<DEC> iteration

-o<HEX> Buffer offset (def=00000000)

-p<HEX> Pattern of Data


0 - byte increment ; 1- byte decrement
2 - FF's ; 3 - 00's ; 4- AA 55 ... ; 5 - 55 AA ...
6 - FFFFFFFF 000000000 FFFFFFFF 00000000
7 - FFFFFFFFFFFFFFFF 0000000000000000
FFFFFFFFFFFFFFFF
8 - FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF 0000000000000...
9 - 00000000000000000000000000000000 FFFFFFFFFFFFF...
a - Word Increment ; b - Dword Increment
c - Word Decrement ; d - Dword Decrement (def=00000000)

-q<HEX> low 32-bit of 64-bit pattern (def=FFFFFFFF)

-v<DEC> Verbose (1..2) (def=2)

-w Word Swap

-x<HEX> high 32-bit of 64-bit pattern (def=FFFFFFFF)

-K<HEX> DMA read from abosolute address (def=00000000)

Example:

1. Sup DMA host memory to NIC memory. Using low priority DMA Read and disable
byte swap.

page 101
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

1:> dmar -a=0 -l=100


Device 1
Host Address : 0x0068bb38
NIC Address : 0x00000000
Length : 0x0100
Priority : Low
Byte Swap : No
Word Swap : No

Dev 1: DMA Host 0068BB38 to SRAM 00000000

10.73 dma_h
Command: dma_h

Description: Dump DMA Entries

Syntax: dma_h <start> <end>

10.74 dma_d
Command: dma_d

Description: Dump DMA Entries with Decode

Syntax: dma_d <start> <end>

10.75 dma_alloc
Command: dma_alloc

Description: Allocate number of DMAD (non-BCM5705 family only)

Syntax: dma_alloc <dma count>

10.76 maclpk
Command: maclpk

Description: Configure MAC loopback, 0 to disable, otherwise enable MAC loopback

Syntax: maclpk <n>

0 to disable. Otherwise enable

Example:

1. Driver must be loaded before configure.


0:> loaddrv

2. Enable MAC loop back.

page 102
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

0:> mcaclpb 1
Enabling MAC loopback ... OK

2. Disable MAC loop back.


0:> maclpb 0
Disabling MAC loopback ... OK

10.77 blast
Command: blast

Description: Blast Packets in Poll Mode and display statistics. Load MAC driver before
running the test.

Syntax: blast

Options:

-a<DEC> IP total length (def=0)

-c<DEC> Number of Tx buffer (def=100)

-d<DEC> Interpacket GAP in microseconds (def=0)

-e<DEC> Upper Limit of Tx buffer in incremental packet size (def=1514)

-f<string> Sniffer file containing contents of Tx packets

-g<DEC> Rx Threshold (def=5)

-h Enable Host Loopback

-I Increment length

-j Regenerate CRC-32 in host loopback mode

-k Applies CRC-32 check on Rx path

-l<DEC> Length of Tx packet (def=60)

-m Generate TPROT packets

-n<DEC> Number of packets to be transmitted (def=0)

-o<DEC> Number of Rx Rings (def=1)

-p Send protocol packets configured with txcfg command.

-q Use software CRC-32 on Tx Path

-r Enable Rx

page 103
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-s Stop on Failure

-t Enable Tx

-w<DEC> Low watermark max RxFrame value (0-65535)

-x Check length of received packet

-z<DEC> Tx Threshold (def=5)

-P Pause

-R Enable RS232 statistic update

-S TCP segment test

-T<DEC> Packet Type, 0:None, 1:Eth2, 2:802.3, 4:SNAP

-W Check DMA_Write error status

Example:
1. Load MAC driver and enable transmission.
0:packet> loaddrv
Reinitializing PCI Configuration Space
Bus Number : 1
Device/Funtion : 11/0
Base Address : 0xfb010000
IRQ : 9
Bringing up MAC driver ... OK
PHY calculated ID: 60008162
BCM5702/03 Internal Phy Rev#2
Configuring BCM54xx ... Done
Determining Link Speed ... 1000Base-T Full Duplex
0:packet> blast –t
PageUP/PageDN to scroll. Ins/Del toggles refresh. ESC to exit
Total Rate
=================== ==================
Txed Packets (Ring#0) : 1007609 507523
Txed Packets (Ring#1) : 0 0
Txed Packets (Ring#2) : 0 0
Txed Packets (Ring#3) : 0 0
Tx Packets Enqed (Ring#0) : 0 0
Tx Packets Enqed (Ring#1) : 0 0
Tx Packets Enqed (Ring#2) : 0 0
Tx Packets Enqed (Ring#3) : 0 0
Rxed Packets (Ring#00) : 0 0
Rxed Packets (Ring#01) : 0 0
Rxed Packets (Ring#02) : 0 0
Rxed Packets (Ring#03) : 0 0
Rxed Packets (Ring#04) : 0 0
Rxed Packets (Ring#05) : 0 0
Rxed Packets (Ring#06) : 0 0
Rxed Packets (Ring#07) : 0 0
Rxed Packets (Ring#08) : 0 0
Rxed Packets (Ring#09) : 0 0

PageUP/PageDN to scroll. Ins/Del toggles refresh. ESC to exit

page 104
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.78 nicstats
Command: nicstats

Description: Display NIC Statistics

Syntax: nicstats <-c>

-c : Clear Statististics

Example: Load driver if driver is not loaded.


0:> loaddrv
Reinitializing PCI Configuration Space
Bus Number : 1
Device/Funtion : 11/0
Base Address : 0xfb010000
IRQ : 9
Bringing up MAC driver ... OK
PHY calculated ID: 60008162
BCM5702/03 Internal Phy Rev#2
Configuring BCM54xx ... Done
Determining Link Speed ... 1000Base-T Full Duplex
0:> nicstats
Total Rate
=================== ==================
Txed Packets (Ring#0) : 0 0
Txed Packets (Ring#1) : 0 0
Txed Packets (Ring#2) : 0 0
Txed Packets (Ring#3) : 0 0
Tx Packets Enqed (Ring#0) : 0 0
Tx Packets Enqed (Ring#1) : 0 0
Tx Packets Enqed (Ring#2) : 0 0
Tx Packets Enqed (Ring#3) : 0 0
Rxed Packets (Ring00) : 0 0
Rxed Packets (Ring01) : 0 0
Rxed Packets (Ring02) : 0 0
Rxed Packets (Ring03) : 0 0
Rxed Packets (Ring04) : 0 0
Rxed Packets (Ring05) : 0 0
Rxed Packets (Ring06) : 0 0
Rxed Packets (Ring07) : 0 0
Rxed Packets (Ring08) : 0 0
Rxed Packets (Ring09) : 0 0

PageUP/PageDN to scroll. Ins/Del toggles refresh. ESC to exit

Total Rate
=================== ==================
Rxed Packets (Ring#10) : 0 0
Rxed Packets (Ring#11) : 0 0
Rxed Packets (Ring#12) : 0 0
Rxed Packets (Ring#13) : 0 0
Rxed Packets (Ring#14) : 0 0
Rxed Packets (Ring#15) : 0 0
Rxed CRC-32 Errors : 0 0
Out of Memory : 0 0
Too Many Frag Pkt : 0 0

page 105
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

PageUP/PageDN to scroll. Ins/Del toggles refresh. ESC to exit

CHIP Statistics
=========================================================================
ifHCInOctets : 0 etherStatsFragments : 0
ifHCInUcastPkts : 0 ifHCInMulticastPkts : 0
ifHCInBroadcastPkts : 0 d3StatsFCSErrors : 0
d3StatsAlignmentErrors : 0 xonPauseFramesReceived : 0
xoffPauseFramesReceived: 0 macControlFramesReceived: 0
xoffStateEntered : 0 dot3StatsFramesTooLong : 0
etherStatsJabbers : 0 etherStatsUndersizePkts : 0
inRangeLengthError : 0 outRangeLengthError : 0
etherStatsPkts64Octets : 0 etherStatsPkts65-127 : 0
etherStatsPkts128-255 : 0 etherStatsPkts256-511 : 0
etherStatsPkts512-1023 : 0 etherStatsPkts1024-1522 : 0
etherStatsPkts1523-2047: 0 etherStatsPkts2048-4095 : 0
etherStatsPkts4096-8191: 0 etherStatsPkts8192-9022 : 0
ifHCOutOctets : 0 etherStatsCollisions : 0
outXonSent : 0 outXoffSent : 0
flowControlDone : 0 d3StatsIntlMacTxErrors : 0
d3StatsSingleColFrames : 0 d3StatsMultipleColFrames: 0
dt3StatsDeferredTx : 0 d3StatsExcessiveCol : 0

PageUP/PageDN to scroll. Ins/Del toggles refresh. ESC to exit

CHIP Statistics
=========================================================================
d3StatsLateCol : 0 d3Collided2Times : 0
d3Collided3Times : 0 d3Collided4Times : 0
d3Collided5Times : 0 d3Collided6Times : 0
d3Collided7Times : 0 d3Collided8Times : 0
d3Collided9Times : 0 d3Collided10Times : 0
d3Collided11Times : 0 d3Collided12Times : 0
d3Collided13Times : 0 d3Collided14Times : 0
d3Collided15Times : 0 ifHCOutUcastPkts : 0
d3StatsCarSenseErrors : 0 ifOutDiscards : 0
COSIfHCInPkts[00] : 0 COSIfHCInPkts[01] : 0
COSIfHCInPkts[02] : 0 COSIfHCInPkts[03] : 0
COSIfHCInPkts[04] : 0 COSIfHCInPkts[05] : 0
COSIfHCInPkts[06] : 0 COSIfHCInPkts[07] : 0
COSIfHCInPkts[08] : 0 COSIfHCInPkts[09] : 0
COSIfHCInPkts[10] : 0 COSIfHCInPkts[11] : 0
COSIfHCInPkts[12] : 0 COSIfHCInPkts[13] : 0
COSIfHCInPkts[14] : 0 COSIfHCInPkts[15] : 0
COSFrmsDxDueToFilters : 0 nicDmaWriteQueueFull : 0
nicDmaWrHiPQFull : 0 nicNoMoreRxBDs : 0

PageUP/PageDN to scroll. Ins/Del toggles refresh. ESC to exit

PageUP/PageDN to scroll. Ins/Del toggles refresh. ESC to exit


CHIP Statistics
=========================================================================
ifInDiscards : 0 ifInErrors : 0
nicRecvThresholdHit : 0 nicDmaReadQueueFull : 0
COSIfHCOutPkts[00] : 0 COSIfHCOutPkts[01] : 0
COSIfHCOutPkts[02] : 0 COSIfHCOutPkts[03] : 0
COSIfHCOutPkts[04] : 0 COSIfHCOutPkts[0
Rxed Packets (Ring#05) : 0 0
Rxed Packets (Ring#06) : 0 0
Rxed Packets (Ring#07) : 0 0
Rxed Packets (Ring#08) : 0 0

page 106
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Rxed Packets (Ring#09) : 0 0

PageUP/PageDN to scroll. Ins/Del toggles refresh. ESC to exit

10.79 ringIndex
Command:

Description: Dump Ring Index. Load Mac driver before running.

Syntax: ringindex t | r

Options:

-n<DEC> Number of Rx Ring to dump (Default=1) (def=1)

-r Dump Rx Ring Index

-t Dump Tx Ring Index

Example:

1 Load MAC dirver and display TX and RX Ring Index.


0:> loaddrv
Bus Number : 1
Device/Funtion : 11/0
Base Address : 0xfb010000
IRQ : 9
Bringing up MAC driver ... OK
PHY calculated ID: 60008162
BCM5702/03 Internal Phy Rev#2
Configuring BCM54xx ... Done
Determining Link Speed ... 1000Base-T Full Duplex
0:> ringindex rt

Mailbox RBDI RBDC HC StsBlk Driver


======= ====== ====== ====== ======= ======
RxStdPidx 100 100 100 --- --- 100
RxStdCidx --- --- --- 000 000 000
RetRPidx#00 --- --- --- 000 --- ---
RetRCidx#00 000 --- --- --- --- 000

Mailbox SBDI SBDSEL HC StsBlk Driver


======= ====== ====== ====== ======= ======
SendHostPidx#00 000 000 --- --- --- 000
SendHostCidx#00 --- --- 000 000 000 000
SendHostPidx#01 000 000 --- --- --- 000
SendHostCidx#01 --- --- 000 000 000 000
SendHostPidx#02 000 000 --- --- --- 000
SendHostCidx#02 --- --- 000 000 000 000
SendHostPidx#03 000 000 --- --- --- 000
SendHostCidx#03 --- --- 000 000 000 000

page 107
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.80 phyctrl
Command: phyctrl

Description: Configure Phy Speed

Syntax: phyctrl

Options:

-f<string> file contains initialization scripts

-h force half duplex

-r reset PHYs

-s<HEX> 0:10 Mbps, 1:100 Mbps, 2:1000 Mbps, 3 - Auto (def=00000002)

10.81 txpkt
Command: txpkt

Description: Transmit Packets. Driver must be loaded.

Syntax: txpkt

Options:

-a<DEC> Specify number of IP fragment count (def=0)

-b<DEC> Burst length (def=0)

-c Clear Statistics (always on: kept for bcmediag compatibility

-d<DEC> Interpacket delay in microseconds (def=txcfg)

-e Insert raw checksum into the packet

-f<DEC> Max number of fragments (def=1)

-g<HEX> Tx Flags (def=txcfg)

-h<DEC> Specifies IP total length (Default: correct IP length)

-I Incremental length

-j Random number of fragments

-k Use random packet length

page 108
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-l<DEC> Start packet length (def=txcfg)

-m Use multiple Tx ring test (def=txcfg)

-n<DEC> Number of packet to transmit (def=0)

-o<HEX> Buffer Offset (def=00000000)

-p<DEC> Number of Tx rings to use in multiple ring test (def=txcfg)

-q<DEC> Number of Packets per ring (def=txcfg)

-r<DEC> Tx ring number (def=txcfg)

-v Insert fragment count and fragment size into the packet

-x Display Statistics (always on: kept for bcmediag compatibility

-u Standard Fragmentation

-w<DEC> Low watermark max RxFrame value (0-65535)

-z<DEC> Minimum fragment size, -1=disable (def=-1)

-A Use static buffer

-B<HEX> Begin Cipher ID for the IPSec test. (This command only valid for
the IPSec supported devices).

-E<HEX> End Cipher ID for the IPSec test. (only valid for IPSec supported
devices). Combine this options with –B<HEX> options can specify
the testing range of IPSec algorithm.

-G<HEX> IPSec random test.

-L Don't initialize packets

-R Enable RS232 statistic update

-S TCP segmentation test -V<DEC> Create IPV4 or IPV6 IPS


packets. (def= V4)

1: Random mix Non-IPsec/IPsec packets

2: Random GCM/GMAC salt.

4:Random encryption/authentication keys.

7: Random all above.

page 109
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-H<DEC> Percentage of the IPSec packets if Random mix Non-IPSec/IPSec


packets.

10.82 statusblk
Command: statusblk

Description: Display Status Block

Syntax: statusblk

Example:
0:> statusblk

************** STATUS Block @ 0x0027c040 *************


Status : 0x0000
Rx Standard CIdx : 0 Rx Jumbo CIdx : 0 Rx Mini CIdx : 0
Rx PIdx[00] : 0 Send CIdx[00] : 0
Rx PIdx[01] : 0 Send CIdx[01] : 0
Rx PIdx[02] : 0 Send CIdx[02] : 0
Rx PIdx[03] : 0 Send CIdx[03] : 0
Rx PIdx[04] : 0 Send CIdx[04] : 0
Rx PIdx[05] : 0 Send CIdx[05] : 0
Rx PIdx[06] : 0 Send CIdx[06] : 0
Rx PIdx[07] : 0 Send CIdx[07] : 0
Rx PIdx[08] : 0 Send CIdx[08] : 0
Rx PIdx[09] : 0 Send CIdx[09] : 0
Rx PIdx[10] : 0 Send CIdx[10] : 0
Rx PIdx[11] : 0 Send CIdx[11] : 0
Rx PIdx[12] : 0 Send CIdx[12] : 0
Rx PIdx[13] : 0 Send CIdx[13] : 0
Rx PIdx[14] : 0 Send CIdx[14] : 0
Rx PIdx[15] : 0 Send CIdx[15] : 0

10.83 stsblk
Command: stsblk

Description: Display Statistics Block.

Syntax: stsblk

Example:
0:> stsblk
************** STATISTICS Block @ 0x0027c0c0 *************
ifHCInOctets : 0 etherStatsFragments : 0
ifHCInUcastPkts : 0 ifHCInMulticastPkts : 0
ifHCInBroadcastPkts : 0 d3StatsFCSErrors : 0
d3StatsAlignmentErrors : 0 xonPauseFramesReceived : 0
xoffPauseFramesReceived : 0 macControlFramesReceived: 0
xoffStateEntered : 0 dot3StatsFramesTooLong : 0
etherStatsJabbers : 0 etherStatsUndersizePkts : 0
inRangeLengthError : 0 outRangeLengthError : 0
etherStatsPkts64Octets : 0 etherStatsPkts65-127 : 0
etherStatsPkts128-255 : 0 etherStatsPkts256-511 : 0
etherStatsPkts512-1023 : 0 etherStatsPkts1024-1522 : 0
etherStatsPkts1523-2047 : 0 etherStatsPkts2048-4095 : 0
etherStatsPkts4096-8191 : 0 etherStatsPkts8192-9022 : 0

page 110
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

ifHCOutOctets : 0 etherStatsCollisions : 0
outXonSent : 0 outXoffSent : 0
flowControlDone : 0 d3StatsIntlMacTxErrors : 0
d3StatsSingleColFrames : 0 d3StatsMultipleColFrames: 0
dt3StatsDeferredTx : 0 d3StatsExcessiveCol : 0
d3StatsLateCol : 0 d3Collided2Times : 0
d3Collided3Times : 0 d3Collided4Times : 0
d3Collided5Times : 0 d3Collided6Times : 0
d3Collided7Times : 0 d3Collided8Times : 0
d3Collided9Times : 0 d3Collided10Times : 0
d3Collided11Times : 0 d3Collided12Times : 0
d3Collided13Times : 0 d3Collided14Times : 0
d3Collided15Times : 0 ifHCOutUcastPkts : 0
d3StatsCarSenseErrors : 0 ifOutDiscards : 0
COSIfHCInPkts[00] : 0 COSIfHCInPkts[01] : 0
COSIfHCInPkts[02] : 0 COSIfHCInPkts[03] : 0
COSIfHCInPkts[04] : 0 COSIfHCInPkts[05] : 0
COSIfHCInPkts[06] : 0 COSIfHCInPkts[07] : 0
COSIfHCInPkts[08] : 0 COSIfHCInPkts[09] : 0
COSIfHCInPkts[10] : 0 COSIfHCInPkts[11] : 0
COSIfHCInPkts[12] : 0 COSIfHCInPkts[13] : 0
COSIfHCInPkts[14] : 0 COSIfHCInPkts[15] : 0
COSFrmsDxDueToFilters : 0 nicDmaWriteQueueFull : 0
nicDmaWrHiPQFull : 0 nicNoMoreRxBDs : 0
ifInDiscards : 0 ifInErrors : 0
nicRecvThresholdHit : 0 nicDmaReadQueueFull : 0
COSIfHCOutPkts[00] : 0 COSIfHCOutPkts[01] : 0
COSIfHCOutPkts[02] : 0 COSIfHCOutPkts[03] : 0
COSIfHCOutPkts[04] : 0 COSIfHCOutPkts[05] : 0
COSIfHCOutPkts[06] : 0 COSIfHCOutPkts[07] : 0
COSIfHCOutPkts[08] : 0 COSIfHCOutPkts[09] : 0
COSIfHCOutPkts[10] : 0 COSIfHCOutPkts[11] : 0
COSIfHCOutPkts[12] : 0 COSIfHCOutPkts[13] : 0
COSIfHCOutPkts[14] : 0 COSIfHCOutPkts[15] : 0
nicDmaRdHPQueueFull : 0 nicSendDataCompQueueFull: 0
nicRingSetSdPIdx : 0 nicRingStatusUpdate : 0
nicInterrupts : 0 nicAvoidedInterrupts : 0
nicSendThresholdHit : 0
Phy CRC counter : 0

10.84 txcfg
Command: txcfg

Description: Configure protocol packets for transmission

Syntax: txcfg

Example:
0:> txcfg
1. Source MAC : [Link]
2. Destination MAC : [Link]
3. Length (14-65535) : 1514
4. Packet Type {Non(0),EthV2(1),802.3(2),SNAP(3)}: Ethernet II
5. Protocol Field {Non(0),IP(1),ARP(2),BRM(3)} : IP
6. Source IP : [Link]
7. Destination IP : [Link]
8. IP Protocol Field { UDP(17), TCP(6) } : UDP
80. Source Port : 100
81. Destination Port : 200
9. IP Option Length (32-bit Words) : 0
10. TCP Option Length (32-bit Words) : 0
11. Pattern { As-is(0), Inc(1), Random(2), 0s(3), FFs(4),
AA55(5), 55AA(6),IP_Iden-Inc(7),Load from file(8)
00ff8(9) 00ff16(10), 00ff32(11), 00ff(12)} : Increment (00,01,02 ...)

page 111
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

12. IP Checksum Offload{ YES(1), NO(0) } : NO


13. TCP/UDP Checksum Offload { YES(1), NO(0) } : NO
14. TCP/UDP Pseudo Checksum Only { YES(1), NO(0) }: NO
15. Insert VLAN Tag { YES(1), NO(0) } : NO
16. VLAN Tag : 1
17. Random IP header field { YES(1), NO(0) } : NO
18. Random TCP/UDP header field { YES(1), NO(0) } : NO
0. Exit

Enter your choice (option=paramter) ->

10.85 rxcfg
Command: rxcfg

Description Configure RX parameters.

Syntax: rxcfg

Example:
0:> rxcfg
1. Host Loopback { Enable(1), Disable(0) } : Disable
2. Modify Rx Packet { Enable(1), Disable(0) } : Disable
3. Dump Rx Packet { None(1),Hex(2), Decode(3) } : None
4. Dump Rx Length : 64
5. Tx Fragment Length : 1518
6. Tx Flags : 0000
7. Tx VLAN Tag : 0000
8. Tx Ring Number : 0
9. Tx Generate CRC { Enable(1), Disable(0) } : Enable
10. Capture Rx Pacpket { Enable(1), Disable(0) } : Enable
11. Rx Mask
0. Exit

Enter your choice (option=paramter) ->

10.86 tprot
Command: tprot

Description: Blast with TPROT Packets. This command is same as command 'blast -trm'

Syntax: tprot

Options:

-d<DEC> Interpacket gap in microseconds (def=10)

10.87 qstat
Command: qstat

Description: Get a quick NIC statistic. [qstat string] used to select specific statistic.

Syntax: qstat [qstat string]

page 112
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Options:

-c Clear statistic

-l List all qstat string

10.88 drvrcfg
Command: drvrcfg

Description: configure driver parameters

Syntax: drvrcfg

Options:

-a<DEC> Turn on/off autolink capability (def=0)

-q<DEC> Configure Rx ring size (def=0)

-r<DEC> Turn on/off rxflow capability (def=0)

-t<DEC> Turn on/off txflow capability (def=0)

-x<DEC> Configure Tx ring size (def=0)

10.89 irt
Command: irt

Description: Test an individual register. Test an individual register with a specified


number of reads/writes.

Syntax: irt

Options:

-n<DEC> Number of read/write accesses (def=1)

-r<string> Register offset

10.90 macmrd
Command: macmrd

Description: Test an individual register. Test an individual register with a specified


number of reads/writes.

Syntax: macmrd

page 113
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Options:

-d<DEC> Delay in uS (def=0)

-n<DEC> Number of read/write accesses (def=1)

-r<string> Register offset

10.91 miimrd
Command: miimrd

Description: Test an individual register. Test an individual register with a specified


number of reads/writes.

Syntax: miimrd

Options:

-d<DEC> Delay in uS (def=0)

-n<DEC> Number of read/write accesses (def=1)

-r<string> Register offset

10.92 pcimrd
Command: pcimrd

Description: Test an individual register. Test an individual register with a specified


number of reads/writes.

Syntax: pcimrd

Options:

-d<DEC> Delay in uS (def=0)

-n<DEC> Number of read/write accesses (def=1)

-r<string> Register offset

10.93 inband
Command: inband

Description: Force inband

Syntax: inband

page 114
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Options:

-s<HEX> Standard inband only(5701 GPHY) 0:disable, 1:enable (def=0)

-x<HEX> Extend inband, 0:disable Tx/Rx, 1:enable Tx, 2:enable Rx,


3:enable Tx/Rx. (def=0)

10.94 mwrite
Command: mwrite

Description: Write PHY registers via MII Management interface

Syntax: mwrtie <addr > <data>

Address range: 0x00 – 0x1F

Example:

1. Write 0x15 to MII register 2


0:> mwrite 2 15

10.95 mread
Command: mread

Description: Read PHY registers via MII Management interface

Syntax: mread <begin>[-<end> | <len>]

Address range: 0x00 – 0x1F

Example:

1. Read MII register 0


0:> mread 0
00: 1100

2 Read MII registers 0 to 10


0:> mread 0-10
00: 1100 7949 0020 6051 01e1 0000 0004 2001
08: 0000 0300 0000 0000 0000 0000 0000 3000
10: 0002

3. Read 5 MII registers start from register 0


0:> mread 0 5
00: 1100 7949 0020 6051 01e1

page 115
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.96 mdev
Command: mdev

Description: Select current PHY to be accessed. The default device ID is 0x01. If no


parameter is entered, it displays the current PHY address setting. This controls the internal
phy_device2 setting in the diagnostic.

Syntax: mdev [<phy_id>]

Example:
0:> mdev 1
Phy Address = 0x1

10.97 m2dev
Command: m2dev

Description: Select current PHY to be accessed. The default device ID is 0x01. If no


parameter is entered, it displays the current PHY address setting. This controls the internal
phy_device1 setting in the diagnostic.

Syntax: m2dev [<phy_id>]

Example:
0:> m2dev 1
Phy Address = 0x1

10.98 miimode
Command: miimode

Description: Select Auto Mode of MII Access. 0:disable, 1:enable

Syntax: miimode <1|0>

Example:
0:> miimode 0
Setting MII auto mode to OFF
0:> miimode 1
Setting MII auto mode to ON
0:> miimode

10.99 lbertram
Command: lbertram

Description: Load data to PHY BIST RAM


Syntax: lbertram [filename]

Options:

page 116
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-c<DEC> channel number (def=0)

-e enable BIST

-f<string> File name containing BIST data

10.100 dbertram
Command: dbertram

Description: Dump PHY BIST RAM


Syntax: dbertram

Options:
-b<HEX> Begin of BIST RAM (def=00000000)

-c<DEC> channel number (def=0)

-e<HEX> End of BIST RAM (def=000000FF)

-r Dump Rx BIST RAM

-t Dump Tx BIST RAM

10.101 bertstats
Command: bertstats

Description: Dump PHY BIST statistics

Syntax: bertstats

10.102 rm
Command: rm

Description: Read MII Registers

Syntax: rm

10.103 mrloop
Command: mrloop

Description: loop on MII read. This is special test routine for MII read. It loops on MII
register read util user abort or if value is zero.

page 117
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Syntax: mrloop <addr>

10.104 phymse
Command: phymse

Description: PHY mean square error.

Syntax: phymse
Options:
-p Polling continuously at 100ms interval

10.105 initphy
Command: initphy

Description: Initialize phy.

Syntax: initphy

10.106 tapdump
Command: tapdump

Description: Read PHY internal TAP values

Syntax: tapdump <dfe> | <echo> | <sd> | <mse>

10.107 memsearch
Command: memsearch

Description: Search a Data Pattern in Memory. The default, begin address = 0, and len =
0x20000. The data pattern must be specified.

Syntax: memsearch begin[-end | len] data

10.108 read
Command: read

Description: Read Memory

Syntax: read [!#*$~^lImSsxX]<begin> [-end | len]

! = Configuration space (32)

S = Configuration space (16)

page 118
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

X = Configuration space (8)

# = Registers (32) (default)

* = SRAM (32)

$ = NVRAM (SEEPROM/FLASH) (32)

m = MII registers (16)

~ = VPD Access (32)

I = indirect access of host memory (32)

^ = internal scratchpad (32)

l = direct access of host memory (32)

s = direct access of host memory (16)

x = direct access of host memory (8)

Example:

1. Read from Configuration space


0:> read !10
000010: f4000004

2. Read from Register


0:> read #10
000010: f4000004

3. Read from SRAM


0:> read *10
000010: 00010001

4. Read from internal scratchpad


0:> read ^00
000000: 000312ae

10.109 write
Command: writeDescription: Write Memory

Syntax: write [!#*$~^lImSsxX]<address> [-end | len] data

! = Configuration space (32)

S = Configuration space (16)

X = Configuration space (8)

page 119
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

# = Registers (32) (default)

* = SRAM (32)

$ = NVRAM (SEEPROM/FLASH) (32)

m = MII registers (16)

~ = VPD Access (32)

I = indirect access of host memory (32)

^ = internal scratchpad (32)

l = direct access of host memory (32)

s = direct access of host memory (16)

x = direct access of host memory (8)

Example:

1. Write to configuration space.


0:> write !10 f4000004

2. Write to register.
0:> write #10 f4000004

3. Write to SRAM
0:> write *10 10001

4. Write to internal scratchpad


0:> write ^10 f4000004

10.110 poll
Command: poll

Description: poll Memory

Syntax: poll [!#*$~^lImSsxX]<addr> [[!#*$~^lImSsxX]<addr>...]

! = Configuration space (32)

S = Configuration space (16)

X = Configuration space (8)

# = Registers (32) (default)

page 120
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

* = SRAM (32)

$ = NVRAM (SEEPROM/FLASH) (32)

m = MII registers (16)

~ = VPD Access (32)

I = indirect access of host memory (32)

^ = internal scratchpad (32)

l = direct access of host memory (32)

s = direct access of host memory (16)

x = direct access of host memory (8)


Options:
-n<DEC> Number of changes to print before stop (def=0)

10.111 setbit
Command: setbit

Description: Read-Modify Memory by ored with <bits>

Syntax: setbit [!#*$~^lImSsxX]<addr> <bit#> [<bit#>] ...

! = Configuration space (32)

S = Configuration space (16)

X = Configuration space (8)

# = Registers (32) (default)

* = SRAM (32)

$ = NVRAM (SEEPROM/FLASH) (32)

m = MII registers (16)

~ = VPD Access (32)

I = indirect access of host memory (32)

^ = internal scratchpad (32)

page 121
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

l = direct access of host memory (32)

s = direct access of host memory (16)

x = direct access of host memory (8)

10.112 clearbit
Command: clearbit

Description: Read-Modify Memory by anded with ~<bits>

Syntax: clearbit [!#*$~^lImSsxX]<addr> <bit#> [<bit#>] ...

! = Configuration space (32)

S = Configuration space (16)

X = Configuration space (8)

# = Registers (32) (default)

* = SRAM (32)

$ = NVRAM (SEEPROM/FLASH) (32)

m = MII registers (16)

~ = VPD Access (32)

I = indirect access of host memory (32)

^ = internal scratchpad (32)

l = direct access of host memory (32)

s = direct access of host memory (16)

x = direct access of host memory (8)

10.113 readbit
Command: readbit

Description: Read the bit specified by <bit#>

Syntax: readbit [!#*$~^lImSsxX]<addr> <bit#>

! = Configuration space (32)

page 122
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

S = Configuration space (16)

X = Configuration space (8)

# = Registers (32) (default)

* = SRAM (32)

$ = NVRAM (SEEPROM/FLASH) (32)

m = MII registers (16)

~ = VPD Access (32)

I = indirect access of host memory (32)

^ = internal scratchpad of host memory (32)

l = direct access of host memory (32)

s = direct access of host memory (16)

x = direct access of host memory (8)

10.114 cread
Command: cread

Description: Read PCI configuration Space of specified device. default - 32 bits read, S -
16 bits read, X - 8 bits read
Syntax: cread <bus> <dev> <func> [S|X]<begin> [-end | len]

10.115 cwrite
Command: cwrite

Description: Write PCI configuration space of specified device. default - 32 bits read, S -
16 bits read, X - 8 bits read
Syntax: cwrite <bus> <dev> <func> [S|X]<begin> [-end | len] data

10.116 pcird
Command: pcird

Description: Read PCI configuration word.


Syntax: pcird <bus> <dev> <func> <addr>

Example: pcird 2 1 0 8 : pcird 2 1 0 8 : Read PCI device 1,


function 0 on bus 2.

page 123
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.117 pciwr
Command: pcird

Description: Write PCI configuration word.


Syntax: pcirwr <bus> <dev> <func> <addr> <dword>

Example: pciwr 2 1 0 8 9 : Write PCI device 1, function 0 on


bus 2 with a 9.

10.118 vpdtest
Command: vpdtest

Description: Run VPD Memory Test. Write designed pattern toVPD storage. Then read
back and compare with designed pattern.

Syntax: vpdtest
Options:
-d Force destructive test

-n<DEC> iteration

-p<DEC> Pattern to test (def=0)


0 - Increment; 1 - Decrement ;1 - 0's 2 - FF's ; 3 - AA55; 4 - 55AA

-r Random address test

-w Force write test enable

10.119 regtest
Command: regtest

Description: MAC registers read/write test. Driver must be unloaded.

Syntax: regtest [<iteration>]


Options:
-i Also run indirect memory test

-n<DEC> iteration (The default iteration is 1. 0 means run forever)

-r<DEC> repeat count for each register test (def=1)

-I Do not perform reset before test

page 124
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.120 miitest
Command: miitest

Description: Run MII Memory Test. PHY registers read write test

Syntax: miitest [itereation]


Options:
-n<DEC> iteration (The default iteration is 1. 0 means run forever)

10.121 msi
Command: msi

Description: Run MSI Test Manually

Syntax: msi
Options:
-c<HEX> message count (2 to powered of c) (def=00000003)

-d option removed, kept for bcmediag compatibility

-I initializing MSI block

-o<DEC> offset (def=0)

10.122 memtest
Command: memtest

Description: Test memory blocks such as scratch pad, BD sram, DMA sram, Mbuf,
external SRAM. Running “diagcfg” can configure memory block ranges. See “diagcfg” for
detail. Driver must be unloaded.

Syntax: memtest [iteration]

Options:

-b Test BD SRAM

-c Test MBUF special

-d Test DMA SRAM

-e Test External Memory

-m Test MBUF SRAM

page 125
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-n<DEC> iteration (The default iteration is 1. 0 means run forever)

-p Test CPU GPRs

-s Test Scratch Pad

-x Test MBUF SRAM via DMA

10.123 setest
Command: setest

Description: Run NVRAM Test

Syntax: setest [iteration]

Options:

-e extensive test

-d<HEX> ending offset (with -e option) (def=FFFFFFFF)

-n<DEC> iteration

-q quiet mode

-r read only test

-s<HEX> start offset (with -e option) (def=00000000)

10.124 bist
Command: bist

Description: Run BIST. The default iteration is 1. 0 means run forever.

Syntax: bist [iteration]

10.125 nictest
Command: nictest

Description: Run a set of NIC Tests. NIC test can include memory test, serial eeprom test,
interrupt test, packet exchange, MAC registers test, Mii registers test, cpu test, dma test.
This test can to be configured by running “diagcfg”. See “diagcfg” for details. If a “test
list” is not entered below then a set of default tests are run.

Syntax: nictest [test list]

page 126
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

abcd -- runs all tests

b -- runs all test in group B

a3 b1 -- runs test a3 and b1 only

a124b2 -- runs test a1,a2,a4 and b2

Options:

-e run NVRAM verification also

-n<DEC> iteration

10.126 intrtest
Command: intrtest

Description: Interrupt Test

Syntax: intrtest [iteration]

Options:

-n<DEC> iteration (The default iteration is 1. 0 means run forever.)

10.127 pkttest
Command: pkttest
Description: Perform MAC and/or PHY loopback test. This test will send 100 packets in
incremental length and check for contents of loopbacked packets.

Syntax: pkttest [<iteration>]

Options:

-e run external loopback test

-m run mac loopback test

-n<DEC> iteration (The default iteration is 1. 0 means run forever.)

-p run phy loopback test

10.128 cputest
Command: cputest

page 127
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Description: TX / RX CPU Test. This test needs an input CPU file in the same location as
[Link]. The default file name is [Link] or [Link] unless specified by –f option.

Syntax: cputest [iteration]

Options:

-f<string> input filename

-n<DEC> iteration (The default iteration is 1. 0 means run forever)

10.129 dmatest
Command: dmatest

Description: DMA Test

Syntax: dmatest [iteration]

Options:

-4 Allocate 4k-aligned buffers

-a<HEX> NIC address (def=00002100)

-d Display DMA info.

-f Force to use 32-bit bus

-l<HEX> Length of DATA to do DMA (def=00000400)

-n<DEC> iteration

-o<HEX> Buffer offset (def=00000000)

10.130 teste
Command: teste

Description: The command enables tests. It affects nictest, regtest, pkttest, and memtest
commands. The test must starts with test group alphabet (a-d). If no number
is entered, all tests in that group are enabled.

Syntax: teste [<tests> [<tests>…]]

Example: teste a12bc -- Enable test a1, a2, all tests in group b and c
teste ab cd -- Enables all tests
teste -- Display enabled tests

page 128
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.131 testd
Command: testd

Description: The command disables tests. It affects nictest, regtest, pkttest, and memtest
commands. The test must starts with test group alphabet (a-d). If no number
is entered, all tests in that group are disabled.

Syntax: testd [<tests> [<tests>…]]

Example: testd a12bc -- Disable test a1, a2, and all tests in group b and c.
testd ab cd -- Disables all tests.
testd -- Display disabled tests.

10.132 asftest
Command: asftest

Description: ASF Test

Syntax: asftest

Options:

-n<DEC> iteration

10.133 bustest
Command: bustest

Description: PCI Bus Test

Syntax: bustest

Options:

-a<HEX> NIC address to DMA data to. (def=00002100)

-d<HEX> delay poll dma done polling (def=00000000)

-e<DEC> End of test case (def=259)

-g Insert debugging information

-h<DEC> Maxmum length (def=1024)

-i<DEC> Number of transactions per pattern (def=10)

-l<DEC> Minimum length (def=256)

page 129
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-n<DEC> iteration

-o<DEC> Number of consecutive patterns (def=1)

-p<DEC> DMA priority (def=0)

-s<DEC> Start of test case (def=0)

-t<DEC> Transient fixed pattern (def=0)

-v<DEC> Verbose level (0..2) (def=1)

-L Loop

There are total 260 test cases (258 unique tests cases) which are described as follows:

Test case# Pattern


========== ==================================
0 ffffffff ffffffff 00000000 00000000
1 ffffffff fffffffe 00000000 00000000
2 ffffffff fffffffd 00000000 00000000
. .
. .
. .
64 7fffffff ffffffff 00000000 00000000
65 00000000 00000000 ffffffff ffffffff
66 00000000 00000000 ffffffff fffffffe
67 00000000 00000000 ffffffff fffffffd
. .
. .
. .
129 00000000 00000000 7fffffff ffffffff
130 00000000 00000000 ffffffff ffffffff (repeat)
131 00000000 00000001 ffffffff ffffffff
132 00000000 00000002 ffffffff ffffffff
. .
. .
. .
194 80000000 00000000 ffffffff ffffffff
195 ffffffff ffffffff 00000000 00000000 (repeat)
196 ffffffff ffffffff 00000000 00000001
197 ffffffff ffffffff 00000000 00000002
. .

page 130
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

. .
. .
259 ffffffff ffffffff 80000000 00000000

If you run bustest command without any parameters, it will perform DMA testing on all 260 patterns with 10
iterations per pattern and different data length in each iteration. First eight bytes of data are used to store the
following info for debug:

byte 0-4 : length


byte 5-6 : iteration#
byte 6-7 : test case#

10.134 sramtest
Command: sramtest

Description: SRAM Test

Syntax: sramtest <begin> [ <len> |<-end>]

10.135 msitest
Command: msitest

Description: MSI Test

Syntax: msitest

Options:

-c<HEX> message count (2 to powered of c) (def=00000003)

-I initializing MSI block

-n<DEC> iteration

10.136 romtest
Command: romtest

Description: ROM Test

Syntax: romtest

Options:

-n<DEC> iteration

page 131
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.137 gpiotest
Command: gpiotest

Description: do GPIO test

Syntax: gpiotest

Options:

-n<DEC> iteration

10.138 cpudiag
Command: cpudiag

Description: run diagnostic from internal CPU

Syntax: cpudiag

Options:

-b Test BD SRAM (0x0000-0x0fff and 0x4000-0x7fff)

-d Test DMA SRAM (0x2000-0x3fff)

-m Test MBUF SRAM (0x8000-0x00000005)

-n<DEC> Iteration

-r Register Test

-T Test with Tx CPU

-R Test with Rx CPU

10.139 pcicfgtest
Command: pcicfgtest

Description: Run PCI Config. Reg. Test

Syntax: pcicfgtest

Options:

-I Do not perform reset before test

-r<DEC> repeat count for each register test (def=1)

page 132
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-n<DEC> iteration

10.140 petest
Command: petest

Description: Perform parity error test on a bridge

Syntax: petest <bridge>

10.141 errctrl
Command: errctrl

Description: Configure Error Control Setting

Syntax: errctrl [w|c|a|l|s]


w - Wait on Error
Program will pause and wait for user's action (eng. default)
c - Continue on Error
Program will continue even if the error is detected
a - Abort on Error (Manufacturing default)
Program stops
l - Loop on Error
Program will retry the same test
s - Skip on Error
Program will skip the rest of the present test

10.142 sedvt
Command: sedvt

Description: Perform NVRAM dvt test. When 'init' subcommand is entered, the NVRAM
is initialized into pseudo random pattern. The original content is DESTROYED.

Syntax: sedvt [init]

Options:

-a Access test

-e Erase with reset

-f force

-l<HEX> size (def=00000100)

-n<DEC> iteration (def=0)

-p pause

-r Read Test with reset

page 133
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-s skip checking entire NVRAM

-w Read/Write Test with reset

10.143 miimisctest
Command: miimisctest

Description: Run MII Misc. Tests.

Syntax: miimisctest

Options:

-n<DEC> iteration

10.144 cpugprtest
Command: cpugprtest

Description: Run CPU GPR test.

Syntax: cpugprtest

Options:

-r run rx_cpu only

-t run tx cpu only

-u run Address Up

10.145 dmashasta
Command: dmashasta

Description: DMA Test

Syntax: dmashasta

Options:

-r Disable the read DMA test

-w Disable the write DMA test

-e Disable the chip reset execution before each DMA test

-l<HEX> Number of BD sot DMA on read (0x1-0x79) (def=0xA)

page 134
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.146 binchksum
Command: binchksum

Description: Verify the checksum of each piece of firmware in the input file that contains a
complete NVRAM image.

Syntax: binchksum –f<filename>

10.147 pmdcfg
Command: pmdcfg

Description: Display Power Management Info

Syntax: pmdcfg

Options:

-a<HEX> 0 to add a pattern; otherwise delete (def=00000000)

-l<HEX> length (def=00000000)

-p<HEX> pattern. 0 - Increment; 1 - Increment (def=00000000)

10.148 pmpd
Command: pmpd

Description: Power Down MAC. Input file [Link] should be found in the same location
of [Link]. The input file contains patterns. If the file name is not specified, data zero
will be used.

Syntax: pmpd [filename]

Options:

-a<HEX> 1 enables ACPI Packet Match (def=00000000)

-c<HEX> 0 to add a pattern; otherwise delete (def=00000000)

-f<string> File name which contains patterns

-m<HEX> 1 enables Magic MAC detection (def=00000000)

-o<HEX> offset (def=00000000)

-v<HEX> Versbose level (default=0) (def=00000000)

page 135
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.149 intr
Command: intr

Description: Dump Interrupt Info

Syntax: intr

Example:
0:> intr
Interrupt Count : 48337
IPC MASK : 0xb8 0x0c
IPC IS1 IS2 : 0x00 0x00
IPC IRR1 IRR2 : 0x18 0x00
IPC ILCR1 ILCR2 : 0x20 0x0e
Worst Intr. Latency : 54476 CPU clocks/50 uS

10.150 intrctrl
Command: intrctrl

Description: Control Interrupt Controller

Syntax: intrctrl u|m


u : unmask current interrupt
m : mask current interrupt

Example:
1. Mask current interrupt
0:irq> intrctrl m
Masking Interrupt 10
2. Unmask current interrupt
0:irq> intrctrl u
Unmasking Interrupt 10

10.151 intt
Command: intt

Description: Interrupt Tracer. This is special function to monitor interrupt functions.

Syntax: intt

10.152 mbuf
Command: mbuf

Description: Dump Content of MBUFs. The display command must be specified by -c


option or 'chain', 'info', 'cluster', 'hdr', and 'ckhdr.

Syntax: mbuf [chain|info|cluster|hdr|ckhdr]

page 136
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Options:

-c<HEX> command
0 - displays a MBUF
1 - displays a MBUF chain
2 - displays general MBUF information
3 - displays MBUF Cluster
4 - Check MBUF header corruption
5 - Dump all MBUF headers

-m<HEX> display mode, 0: decode, 1: in hex (def=00000000)

-n<DEC> MBUF number to display/decode (def=256)

-w MBUF workaround

Example:

1. Display MBUF chain.


0:> mbuf chain
->143->144->145->146->147->148->149->14a->14b->14c->14d->14e->14f->150
->151->152->153->154->155->156->157->158->159->15a->15b->15c->15d->15e
->15f->160->161->162->163->164->165->166->167->168->169->16a->16b->16c
->16d->16e->16f->170->171->172->173->174->175->176->177->178->179->17a

10.153 loaddrv
Command: loaddrv

Description: Load Driver

Syntax: loaddrv

Options:

-4<HEX> Enable 4k-aligned memory (def=00000000)

-o<HEX> Allocate memory with specified offset (def=00000000)

-j Allocate memory for Jumbo packet

-t Allocate memory for TCP Segmentation

-f Force Link to Max Speed

-z Allocate memory for optimization (i.e. DOS with EFI BIOS)

Example:

page 137
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

0:> loaddrv
Reinitializing PCI Configuration Space
Bus Number : 1
Device/Funtion : 11/0
Base Address : 0xfb010000
IRQ : 9
Bringing up MAC driver ... OK
PHY calculated ID: 60008162
BCM5702/03 Internal Phy Rev#2
Configuring BCM54xx ... Done
Determining Link Speed ... 1000Base-T Full Duplex

10.154 unloaddrv
Command: unloaddrv

Description: Unload NIC driver

Syntax: unloaddrv

Example:
0:> unloaddrv

Unloading MAC driver ... OK

10.155 machalt
Command: machalt

Description: Halt MAC controller

Syntax: machalt

Example:
0:> machalt
Halting MAC … OK

10.156 ftq
Command: ftq

Description: Dump FTQ

Syntax: ftq

Example:
0:> ftq

***** Dump FTQ Peak/Write (Control,Full Counter, Write/Peak) *****


DMA Read FTQ (1) : 00000000 00000000 20000000
DMA High Read FTQ (2) : 00000000 00000000 60002160
DMA Write FTQ (6) : 00000000 00000000 20000000
DMA High Write FTQ (7) : 00000000 00000000 20000000
DMA Complete Dx FTQ (3) : 00000000 00000000 20000000
Send BD Comp. FTQ (4) : 00000000 00000000 20000000

page 138
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Send Data Init FTQ (5) : 00000000 00000000 20000000


Send Data Comp. FTQ (9) : 00000000 00000000 20000000
Rx BD Complete FTQ (13) : 00000000 00000000 60002160
Rx Data Complete FTQ (16) : 00000000 00000000 20000000
S/W Type 1 FTQ (8) : 00000000 00000000 20000000
Host Coalescing FTQ (10) : 00000000 00000000 2000:00000000
MAC TX FTQ (11) : 00000000 00000000 2000:00000000
Mbuf Cluster Free FTQ (12): 00000000 00000000 2000:00000000
RX List Placement FTQ (14): 00000000 00000000 2000:00000000
RX Data Initiator FTQ (15): 00000000 00000000 2000:00000000

S/W Type 2 FTQ (17) : 00000000 00000000 2000:00000000

10.157 addmc
Command: addmc

Description: Add Multicast MAC

Syntax: addmc <xx:xx:xx:xx:xx:xx>

Example:
0:> addmc [Link]

10.158 delmc
Command: delmc

Description: Delete Multicast MAC

Syntax: delmc <xx:xx:xx:xx:xx:xx>

Example:
0:> delmc [Link]

10.159 txmacdes
Command: txmacdes

Description: Program Destination address to UUT

Syntax: txmacdes <xx:xx:xx:xx:xx:xx>

10.160 txmacsrc
Command: txmacsrc

Description: Program Source address to UUT

Syntax: txmacsrc <xx:xx:xx:xx:xx:xx>

page 139
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.161 chklddrv
Command: chklddrv

Description: Check to see if driver is loaded. Returns 1 if driver is loaded, returns 0


otherwise.

Syntax: chklddrv

10.162 vlantag
Command: vlantag

Description: Display/Clear vlanTag information.

Syntax: vlantag

Options:

-c clear vlanTag info

10.163 reg
Command: reg

Description: register wizard. This command allows user to view edit registers.

Syntax: reg [pci|mii] [offset]

10.164 exit
Command: exit

Description: Exit System

Syntax: exit

10.165 debug
Command: debug

Description: Display debugs information

Syntax: debug <n>

1: Dump TX / RX Stats

2: Dump Clock Scale info

3: Clear worst interrupt latency

page 140
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

4: Toggle indirect access flag

5: Toggle PCI-X workaround

Example:

1. Display debug information.


0:> debug 1
Tx Packets Enqueued : 0
Tx Packet Complete : 0
Tx Packet Complete Error : 0
Rx Packets : 0
Rx Unknown Packets : 0
Rx Bad Packets : 0
Rx Good Packets : 0

10.166 gpiowrite
Command: gpiowrite

Description: Write a Value into GPIO pin

Syntax: gpiowrite <GPIO_num> < value>

Valid value for <GPIO_num> is 0-3, <value> is 0 or 1.

Example:

1. Write 1 to GPIO#1 Pin


0:> gpiowrite 1 1

Writing 1 to GPIO#1

10.167 gpioread
Command: gpioread

Description: Read GPIO Value

Syntax: gpioread

Example:

1. Read GPIO Pins


0:> gpioread
GPIO#0 : 1
GPIO#1 : 1
GPIO#2 : 0
GPIO#3 : 0

page 141
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.168 pxecpy
Command: pxecpy

Description: Load PXE Code to MBUF Memory. The file name must be specified in the
parameter.

Syntax: pxecpy <file>

Options:

-f<string> filename

10.169 device
Command: device

Description: Show or Switch Device. If no parameter is entered, it will display all device
available.

Syntax: device <dev>

Options:

-n<HEX> Device Number (def=00000000)

-r Remove all current devices and re-scan available devices

-s Silent mode - do not display devices

10.170 version
Command: version

Description: Display Program Version

Syntax: version

10.171 help
Command: help

Description: Enter command group for the list of available commands. If no parameter is
entered, all commands are displayed. Example: help vpd. For each command help, type the
command and then '?'. Example: memtest ?

Syntax: help [vpd|nvram|cpu|dma|packet|mii|mem|test|power|irq|mac|misc]

page 142
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.172 ?
Command: ?

Description: Alternate Help Command. This is same command as 'help' command.

Syntax: ? [vpd|nvram|cpu|dma|packet|mii|mem|test|power|irq|mac|misc]

10.173 radix
Command: radix

Description: Change System Radix. Radix must be 2-16. Radix used for number entry. 16
means enter number in hex, and 10 means in decimal.

Syntax: radix <2 | 8 | 10 | 16>

10.174 nolog
Command: nolog

Description: Close the Current Logfile

Syntax: nolog

10.175 log
Command: log

Description: Save all output to log file

Syntax: log

Options:

-f<string> filename (for bcmediag compatibility only)

-a Append to existing file

10.176 pciinit
Command: pciinit

Description: Initialize PCI configuration registers

Syntax: pciinit

page 143
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.177 pciscan
Command: pciscan

Description: Scan for all PCI Devices

Syntax: pciscan
Example:
0:> pciscan
Scanning PCI devices ...
Bus Dev Func Vendor ID Device ID Class Base/IO Address IRQ
=== === ==== ========= ========= ========== ================= ===
0 0 0 8086 7190 [Link] 00000000:F8000008 0
0 1 0 8086 7191 [Link] 00000000:00000000 0
0 7 0 8086 7110 [Link] 00000000:00000000 0
0 7 1 8086 7111 [Link] 00000000:00000000 0
0 7 2 8086 7112 [Link] 00000000:00000000 9
0 7 3 8086 7113 [Link] 00000000:00000000 0
0 14 0 12AE 0003 [Link] 00000000:F4000004 10
1 0 0 1002 4742 [Link] 00009001:F5000000 11

10.178 dos
Command: dos

Description: Execute DOS command. If no parameter is entered, DOS shell is entered.


Syntax: dos <dos command>

This command is not supported in UEFI version. Use the Shell command instead.

10.179 Shell
Command: shell

Description: Execute a UEFI shell command. If no parameter is entered, the command


terminates. This command only works if the applications is run from the UEFI shell
prompt. This command is not supported in the DOS version. Use the DOS command
instead.

Syntax: shell <shell command>

10.180 diagcfg
Command: diagcfg

Description: Configure diagnostics parameter for Memory tests and Manufacturing test
(NIC test).

Syntax: diagcfg

Example:

page 144
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

0:> diagcfg

Diagnostics Configuration Menu

1. Memory Test Configuration Menu


2. Test Configuration Menu
3. Driver Configuration Menu
4. Abort On Failure is enabled
5. Save Configuration

Enter your choice or ESC to exit -> 1

Memory Test Configuration Menu

1. SRAM BD1 Start (0x00000000-0x00000fff) : 00000000


2. SRAM BD1 End (0x00000000-0x00000fff) : 00000fff
3. SRAM BD2 Start (0x00004000-0x00007fff) : 00004000
4. SRAM BD2 End (0x00004000-0x00007fff) : 00007fff
5. SRAM DMA Start (0x00002000-0x00003fff) : 00002000
6. SRAM DMA End (0x00002000-0x00003fff) : 00003fff
7. SRAM MBUF Start (0x00008000-0x00015fff) : 00008000
8. SRAM MBUF End (0x00008000-0x00015fff) : 00000000
9. SRAM SPAD Start (0x00030000-0x00037fff) : 00030000
10. SRAM SPAD End (0x00030000-0x00037fff) : 00037fff
11. Ext. SRAM Start (0x00020000-0x00ffffff) : 00020000
12. Ext. SRAM End (0x00020000-0x00ffffff) : 00ffffff
13. MBUF Bank (1 - Odd ; 2 - Even ; 3 - Both) : 3
0. Exit to previous menu

Enter your choice (option=paramter) -> 0

Diagnostics Configuration Menu

1. Memory Test Configuration Menu


2. Test Configuration Menu
3. Driver Configuration Menu
4. Abort On Failure is enabled
5. Save Configuration

Enter your choice or ESC to exit -> 2

Test Configuration Menu

A1. Indirect Register.................: Enabled


A2. Control Register..................: Enabled
A3. Interrupt.........................: Enabled
A4. Built In Self.....................: Enabled
A5. PCI Cfg Register..................: Enabled
B1. Scratch Pad.......................: Enabled
B2. BD SRAM...........................: Enabled
B3. DMA SRAM..........................: Enabled
B4. MBUF SRAM.........................: Enabled
B5. MBUF SRAM via DMA.................: Enabled
B6. External SRAM.....................: Disabled
B7. CPU GPR...........................: Enabled
C1. NVRAM.............................: Enabled
C2. CPU...............................: Enabled
C3. DMA...............................: Enabled
C4. MII...............................: Enabled

page 145
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

C5. VPD...............................: Enabled


C6. ASF Miscellaneous.................: Enabled
C7. Expansion ROM.....................: Enabled
D1. MAC Loopback......................: Enabled
D2. PHY Loopback......................: Enabled
D3. External Loopback.................: Disabled
D5. MII Miscellaneous.................: Enabled
D6. MSI...............................: Enabled

Enter test number to toggle or ESC to exit ->

Diagnostics Configuration Menu

1. Memory Test Configuration Menu


2. Test Configuration Menu
3. Driver Configuration Menu
4. Abort On Failure is enabled
5. Save Configuration

Enter your choice or ESC to exit -> 3

Driver Configuration Menu

1. Rx Coalescing Ticks : 1000


2. Rx Coalescing Ticks During Intr : 0
3. Rx Coalescing Frames : 1
4. Rx Coalescing Frames During Intr : 0
5. Tx Coalescing Ticks : 1000
6. Tx Coalescing Ticks During Intr : 0
7. Tx Coalescing Frames : 1
8. Tx Coalescing Frames During Intr : 0
9. Statistics Coalescing Ticks : 1000000
10. Tx Packet Descriptor Count : 50
11. Rx Standard Packet Count : 100
12. Rx Jumbo Packet Count : 50
13. Enable Mini Ring {Yes(1),No(0)} : 1
14. Mini Ring Packet Size (64-512) : 64
15. External Memory Exists {Yes(1), No(0)} : 0
16. MBUF Base : 0x008000
17. MBUF Length : 0x018000
18. Tx Flow Control { Enable(1),Disable(2) } : Disable
19. Rx Flow Control { Enable(1),Disable(2) } : Disable
20. Auto Link Speed { Enable(1),Disable(2) } : Enable
21. Send Ring Size { 32, 64, 128, 256, 512 } : 512
22. Rx Ring Size { 32, 64, 128, 256, 512 } : 512
0. Exit to previous menu

Enter your choice (option=paramter) -> 0

Diagnostics Configuration Menu

1. Memory Test Configuration Menu


2. Test Configuration Menu
3. Driver Configuration Menu
4. Abort On Failure is enabled
5. Save Configuration

Enter your choice or ESC to exit ->

page 146
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.181 reset
Command: reset

Description: Reset Chip

Syntax: reset

Options:

-c Simulate cold reset

-t Display time from reset to firmware invert signature

-w Wait for firmware signature

10.182 quit
Command: quit

Description: Exit System

Syntax: quit

10.183 smbus
Command: smbus

Description: ASF terminal. Run this command to access SMBus, the parameter a1 and a2
are one byte value to specify the NIC SMBus Addresses. It sets to 0 by default.

Syntax: smbus [a1 a2]

Options:

-s Run in slave mode

10.184 cls
Command: cls

Description: Clear Screen.

Syntax: cls

10.185 loop
Command: loop

Description: loop on command.

page 147
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Syntax: loop [iteration] <Command> [<parameter> ...]

10.186 dbmode
Command: dbmode

Description: Set DEBUG Mode to On or Off Mode.

Syntax: dbmode on|off

10.187 asf
Command: asf

Description: run asf monitor program with option to Load asf firmware image. This
routine loads firmware images into CPU memory and execute the RXCPU. The default file
names are [Link], [Link], and [Link], which can be overwritten by
parameters.

Syntax: asf [init_img [rx_img [tx_img]]]

Options:

-l Load firmware only

-m Enter asf mode only

-w Simulate warm boot

10.188 new
Command: new

Description: Display new command available. The default parameter for [n] is 10

Syntax: new [n]

10.189 asfprg
Command: asfprg

Description: Program asf firmware into NVRAM. The default file names are [Link],
[Link], and [Link], which can be overwritten by parameters.

Syntax: asfprg [init_img [rx_img [tx_img]]]

Options:

-v<HEX> verbose level (0,1,2) (def=00000001)

page 148
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.190 sleep
Command: sleep

Description: delay execution for specified length of milliseconds. Can be used in script
files to delay program execution.

Syntax: sleep [milliseconds]

10.191 fillpattern
Command: fillpattern

Description: Fill WOL matching pattern into Misc. Memory Loacation.

Syntax: fillpattern [filename]

Options:

-e<HEX> (end address + 1) of the first block (def=00020000)

-f<string> filename which contains data pattern

-o<HEX> sram first block offset to be loaded (def=00000000)

-s<HEX> sram second block offset to be loaded (def=00000000)

10.192 inp
Command: inp

Description: input port (not supported for UEFI)

Syntax: inp <addr>

Options:

-l long word size

-w word size

10.193 outp
Command: outp

Description: input port (not supported for UEFI)

Syntax: outp <addr> <value>

Options:

page 149
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-l long word size

-w word size

10.194 switch
Command: switch

Description: Alternate 'device' command. If no parameter is entered, it will display all


device available.

Syntax: switch <dev>

Options:

-n<HEX> Device Number (def=00000000)

-r Remove all current devices and re-scan available devices

-s Silent mode - do not display devices

10.195 do
Command: do

Description: Excute commands from a file.

Syntax: do <filename> [with <parameter1>, ...]

Options:

-c continue on error

-e echo command

-p<DEC> pause between each command. If a value is entered, it delays for # of


ms (def=0)

10.196 txfill
Command: txfill

Description: Fill tx buffer with pattern and packet length (14-9018).

Syntax: txfill [-f=]<file> [-x=]<load length> [-p=]<pattern> [-l=]<packet length>

Options:

-f<string> filename

page 150
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-l<DEC> packet length in bytes (14-9018) (def=1514)

-p<DEC> pattern selection (0-8) (def=0)

-x<DEC> length to load in bytes (default to EOF)


Pattern:
0. Use buffer as is
1. Increment data
2. Random
3. all 0
4. all FF
5. AA55
6. 55AA
7. IP_Iden-Inc
8. Load from file
9. 8 bytes of 0 and f
10. 16 bytes of 0 and f
11. 32 bytes of 0 and f
12. 64 bytes of 0 and f

10.197 wbuf
Command: wbuf

Description: Write tx|rx buffer with specified data at offset. Only works with static buffer
selection –A.

Syntax: wbuf tx|rx <offset> <data>

10.198 rbuf
Command: rbuf

Description: Read tx|rx|bistin|bistout|bistex buffer. Read tx|rx|bistin|bistout|bistex buffer


with specified at offset with a specified length. Only works with static buffer selection -A.

Syntax: rbuf tx|rx|bistin|bistout|bistex <offset> <len>

10.199 cpbuf
Command: cpbuf

Description: Copy the content of rx buffer into tx buffer. Only works with static buffer
selection –A.

Syntax: cpbuf <offset> <length>

page 151
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.200 echo
Command: echo

Description: echo <string> to screen.

Syntax: echo <string>

10.201 pause
Command: pause

Description: Pause for user to hit a key. If no parameter is entered, 'press any key to
continue...' will be displayed

Syntax: pause < message>

10.202 q
Command: q

Description: Exit System

Syntax: q

10.203 verbose
Command: verbose

Description: change verbose setting

Syntax: verbose

Options:

-c toggles CONSOLE

-e toggles ERROR

-i toggles IO

-d toggles DEBUG

-p toggles PRINTER

-w toggles WARNING

page 152
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-r toggles Interrupt Verbose

-f toggles flush per line to enable dynamic tracking

10.204 beep
Command: beep

Description: Create a beep sound. The default to beep once. If parameter 'n' is entered, it
beeps n times

Syntax: beep [<n> | on | off]

10.205 var
Command: var

Description: Display current variables

Syntax: var

10.206 meminfo
Command: meminfo

Description: report the memory infomation

Syntax: meminfo

10.207 delvar
Command: delvar

Description: Delete local variables

Syntax: delvar

10.208 regdump
Command: regdump

Description: Dump register content to a file

Syntax: regdump

Options:

-c PCI Config Reg.

page 153
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-f<string> filename

-m MII Registers

-r<DEC> Mac Registers (def=1)

10.209 regcomp
Command: regcomp

Description: Compare register content to a file. This command may be used together with
regdump to find out any register got changed.

Syntax: regcomp <filename>

Options:

-c PCI Config Reg.

-f<string> filename

-m MII Registers

-r<DEC> Mac Registers (def=1)

10.210 regrestore
Command: regrestore

Description: Restore register content from a file. This command may be used together with
regdump to restore register got changed.

Syntax: regrestore <filename>

Options:

-c PCI Config Reg.

-f<string> filename

-m MII Registers

-r<DEC> Mac Registers (def=1)

10.211 nvsize
Command: nvsize

page 154
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Description: Programs the NVRAM and TPM size in Kbyte to NVRAM. If [NVRAM] &
[TPM] options are entered, they are programmed to NVRAM. If [NVRAM] & [TPM]
options are NOT entered, calculated values are programmed. Use a zero value for
[NVRAM] & [TPM] to erase the programmed values.

Syntax: nvsize [NVRAM] [TPM]

Options:

-d Display Present Size Programmed Into NVRAM

-D Specify [NVRAM] & [TPM] size in decimal (dflt. hex)

10.212 aspm
Command: aspm

Description: Configure the PCI-E Link power state operation at the root complex and the
device under test. Power state option described below.
0 ASPM disable
s ASPM L0s enabled
1 ASPM L1 enabled
a ASPM L0s and L1 enabled

Syntax: aspm [-e 0|s|1|a] [-r 0|s|1|a] [-x 0|1] [-d] [-i]

Options:

-r<string> Configure root complex device

-e<string> Configure endpoint (Broadcom) device (dut)

-x<DEC> Enable ExtendedSync mode for root complex and endpoint (def=0)

-d Display present ASPM State

-i Ignore all previous ASPM setting after a chip reset

10.213 dids
Command: dids

Description: The feature outputs the following information: PCI DID, VID, SDID &
SVID; MAC address, Firmware revision, PXE, PXESpd, WOL, ASF, MBA, Bond Rev.
This information can be used to verify the setup of a chip after a firmware upgrade.

Syntax: dids

page 155
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.214 serial
Command: serial

Description: Compares the serial number to defaults or the provided values. This PCI
capability testing is only applicable to Shasta C stepping (i.e. BCM5752Cx) family.

Syntax: serial <dwordLo> <dwordHi>

10.215 power
Command: power

Description: Verify the power function of PCI capability. This PCI capability testing is
only applicable to Shasta C stepping (i.e. BCM5752Cx) family.

Syntax: power

10.216 readbr
Command: readbr

Description: Read a 32-bit value from bridge's configuration space register address.

Syntax: readbr <register address>

10.217 writebr
Command: writebr

Description: Write a 32-bit value to bridge's configuration space register address.

Syntax: writebr <register address> <value>

10.218 findbridge
Command: findbridge

Description: Find all bridges in the system.

Syntax: findbridge

10.219 bridge
Command: bridge

Description: Switch to specified bridge.

Syntax: bridge

page 156
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

10.220 pere
Command: pere

Description: Enable parity error response on a bridge. Defaults to current bridge.

Syntax: pere <bridge>

10.221 perd
Command: perd

Description: Disable parity error response on a bridge. Defaults to current bridge.

Syntax: perd <bridge>

10.222 peclr
Command: peclr

Description: Clear parity error on bridge. Defaults to current bridge.

Syntax: peclr <bridge>

10.223 pechk
Command: pechk

Description: Check parity error on bridge. Defaults to current bridge.

Syntax: pechk <bridge>

10.224 iscsiprg
Command: iscsiprg

Description: Program ISCSI firmware into NVRAM. This command reads ISCSI code
from a file and program into NVRAM. There are 2 types of ISCSI firmware image. One
only contains ISCSI Boot Firmware. The other also contains ISCSI CFG Block and ISCSI
CFG Program. ISCSI Boot Firmware will be programmed by default. ISCSI CFG Block
will be programmed if either there is no ISCSI CFG Block present in NVRAM or “-c”
option has been entered. ISCSI CFG Program will be programmed only when “-p” option
has been entered.

Syntax: iscsiprg [-f<filename>] [-c] [-p] [-v | -b]

Options:

-f<filename> ISCSI firmware file name.

page 157
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-c Forced to program ISCSI CFG FW

-p Forced to program ISCSI CFG Program.

-v Support IPv6 protocol

-b Support IPv4 and IPv6 protocols

10.225 umpecho
Command: umpecho

Description: Enable/Disable UMP Echo Test function in UMP Firmware. It requires


either [Link]/[Link] test firmware or UMP Firmware. Options that will work
with test firmware are ‘-o’, ‘-c’, ‘-i’ and ‘-a’. Options that will work with UMP firmware
are ‘-e’ and ‘-d’.

Syntax: umpecho [-o | -c | -i | -a] | [-e] | [-d]

Options:

-o Running UMP Echo Test with test firmware

-c Debug display of SRAM address 0xC00

-i Debug display of CPU code loading

-a Debug prompt after CPU code loading

-e Enable New UMP Echo Test in UMP Firmware

-d Disable New UMP Echo Test in UMP Firmware

10.226 umpcfg
Command: umpcfg

Description: Configure UMP in NVRAM

Syntax: umpcfg
1 UMP Settings
Description: Provides the sub menu with the options described below.

0 Return to previous menu.


1 Enable/Disable SetLink
2 Enable/Disable RDIStallTimer
3 Set RDIStallTimerValue
4 DisableHostHashTable
5 Enable/Disable HostEchoControl

page 158
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

6 Enable/Disable Exceed_375ma_rule
7 Link Speed
0 : Return to previous menu
1 : Speed 10/100 (default)
2 : Speed ALL
3 : Speed 10
4 : Speed 100
5 : Speed 1000
6 : Duplex
7 : Auto/Force Mode
8 : Pause Capability

2 Save and Exit

Description: Saves the modified UMP Configuration Table to the network adapter's
non-volatile memory and exists.

3 Exit without Saving


Description:
Exits without saving any changes to the UMP Configuration Table.

10.227 setipmi
Command: setipmi

Description: Enable/Disable IPMI Passthrough Firmware

Syntax: setipmi

Options:

-e Enable IPMI Passthrough Firmware

-d Disable IPMI Passthrough Firmware

10.228 setump
Command: setump

Description: Enable/Disable UMP

Syntax: setump

Options:

-d Disable UMP

-e Enable UMP

10.229 seotp
Command: seotp

page 159
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Description: Configure OTP

Syntax: seotp

Options:

-s Show OTP status

-e Update OTP bits

-f<string> filename

10.230 otpchk
Command: otpchk

Description: Check patch in OTP

Syntax: otpchk

Options:

-m Do not check MAC

-n Do not check Configurations and all IDs

-l<HEX> Interation (def=000000001)

-f<string> filename

10.231 defragment
Command: defragment

Description: Defragment NVRAM data.

Syntax: defragment

10.232 secfgsb1
Command: secfgsb1

Description: Configure Selfboot NVRAM Group 1

Syntax: secfgsb1

Options:

-m Mac address xx:xx:xx:xx:xx:xx

page 160
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-v Vendor ID

-z Vendor Device ID

-s SubSystem Vendor ID

-i SubSystem Device ID

-w Magic Packet WOL 1: Enable 2: Disable

-o Limit WOL Speed to 10 0: No 1: Yes

-l Design Type 0: NIC 1: LOM

-p Enable Phy Auto Power Down 0: No 1: Yes

-r Reversed Nway 0: No 1: Yes

-A Disable Power Saving 0: No 1: Yes

-B Led Mode 0: Mac 1:Phy1 2:Phy2 3:S Traffic 4:Shasta Mac 5:Wireless Combo

-C PCI Power Consumption/Dissipate 1:Default 2:Custom define

-c PCI Power Consumption/Dissipate Value D0:D3/D0:D3

-G Cable Sense 0: No 1: Yes

10.233 secfgsb2
Command: secfgsb2

Description: Configure Selfboot NVRAM Group 2

Syntax: secfgsb2

Options:

-D PCIE Pwr Consumption/Dissipate 1: Default 2: Custom define

-d PCIE Pwr Consumption/Dissipate Data;

Data: Pwr Rail: Type: State: Base Power

Select Data = 0-7

Pwr Rail = 0:12V; 1: 3.3V; 2: 1.8V; 7: Thermal; 99: Invalidate

Type = 0: PME 1: Aux 2: Idle 3: Sustained 7: Max

page 161
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Pwr Mgt St = 0: D0 1: D1 2: D2 3: D3

Base Power = X in 0.1 Watt

10.234 secfgsb3
Command: secfgsb3

Description: Configure Selfboot NVRAM Group 3

Syntax: secfgsb3

Options:

-E Product Name 1: Default 2: Custom define

10.235 secfghwsb1
Command: secfghwsb1

Description: Configure Hardware Selfboot NVRAM Group 1

Syntax: secfghwsb1

Options:

-m Mac address xx:xx:xx:xx:xx:xx

-z Vendor Device ID

-s SubSystem Vendor ID

-i SubSystem Device ID

-w WOL

-o Limit WOL Speed to 10 0: No 1: Yes

-a Wol Auto 0:Dis 1: Magic 2: Interest 3: Magic & Interest

-B Led Mode 0: Mac 1:Phy1 2:Phy2 3:S Traffic

-G Super Airplane Mode 0: No 1: Yes

-H Clkreq 0:No 1:Yes

-I PCIE Link Polarity Fix Dis 0:No 1:Yes

page 162
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-n Design Type 0:LOM 1:NIC

-l L1 PLL Powerdown Disable 0:No 1:Yes

-J L1 ASPM Debounce 0:Dis 1:En (PCI-E Mobile Devices Only)

10.236 secfghwsb2
Command: secfghwsb2

Description: Configure Hardware Selfboot NVRAM Group 2

Syntax: secfghwsb2

Options:

-e Engineering Change

-s Serial Number

-m Manufacturing ID

-v Rd VPD Vendor Data V0

10.237 secfghwsb3
Command: secfghwsb2

Description: Configure Hardware Selfboot NVRAM Group 2

Syntax: secfghwsb2

Options:

-h Hide MBA Setup Prompt 0: Dis 1: En

-k MBA Setup Hot Key 0: Ctrl-S 1: Ctrl-B

-m MBA Boot Protocol 0: PXE 1: RPL 2: BOOTP 3: iSCSI

-v Rd VPD Vendor Data V0

-b MBA Bootstrap Type 0: Auto 1: BBS 2: Int18 3: Int19

-t MBA Delay Time 0-15

-e VLan 0: Dis 1:En

-i VLAN ID

page 163
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-s MBA Link Speed 0: Auto 1: 10HD 2: 10FD 3: 100HD 4: 100FD

10.238 eswitch
Command: eswitch

Description: Configure E-Switch on the device that support eswitch, such as 5756 and
5761E.

Syntax: eswitch

Options:

-d Change the port to Docking mode

-l Change the port to Laptop mode

-e Enable E-switch functionality.

-f Disable E-switch functionality. This option will prevent PHY


loopback test, external loopback test (pkttest -e), and carrier test from
being performed on both laptop mode and docking mode. By setting
this option the tests are performed only on the default port.

-m internal engineering manual switch and MAC test

10.239 sbfcfg
Command: sbfcfg

Description: Self-boot file configuration

Syntax: sbfcfg <masterfile> [<upgradefile>]

10.240 linkintrtest
Command: linkintrtest

Description: Link Changed Interrupt Test

Syntax: linkintrtest

10.241 ipv6extld
Command: ipv6extld

Description: Load IPv6 Extension Header File

page 164
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

Syntax: ipv6extld <filename> (default filename is [Link])

10.242 ipv6exten
Command: ipv6exten

Description: Enable IPv6 Extension Headers

Syntax: ipv6exten <0 | 1> (0 = disable, 1 = enable)

10.243 cfgpagesize
Command: cfgpagesize

Description: Configure Flash page size to 256 bytes or 512 bytes.

Syntax: cfgpagesize –v (verbose)

10.244 cpmu
Command: cpmu

Description: CPMU tests

Syntax: cpmu

Options:

-t timeout timer test

-p prescaler timer test, -v –p

-v<HEX> value (def = 00000003)

-r<HEX> reference (def = 00020000)

10.245 mdio
Command: mdio

Description: MDIO tests

Syntax: mdio

Options:

-v<HEX> read MII times (def = 00000200)

page 165
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-t<HEX> available tests:


1: read MII registers with core clock override.
2: write/read/compare MII register with core clock override.
4: read MII registers without core clock override.
8: write/read/compare MII register without core clock override.
f: all above.

10.246 wait
Command: wait

Description: Delay for a bit.

Syntax: wait

Options:

-m<DEC> wait milli seconds (default=1000)

-u<DEC> wait micro seconds (default=1000)

10.247 ipsecsupport
Command: ipsecsupport

Description: Check device for IPsec support.

Syntax: ipsecsupport

10.248 sadbtest
Command: sadbtest

Description: Invoke the Security Association Database (SADB) test. Valid only for IPSec
supported devices.

Syntax: sadbtest

10.249 sadbutil
Command: sadbutil

Description: Utilities for the Security Association Database (SADB) table. Valid only for
IPSec supported devices.

Syntax: sadbutil

Options:

page 166
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

-a Add one SA entry

-d Delete one SA entry

-e Delete all SA entries

-u Dump one SA entry

-U Dump all SA entries

-t Dump internal IPSec transmitted packets digest log for debug


purpose

-r Dump internal IPSec received packets’ digest log for debug purpose

-s Dump internal IPSec statistics counters

-c Clear internal IPSec statistics counters

10.250 apetest
Command: apetest

Description: Run APE CPU Self Tests and utility functions. Only valid for APE enabled
NetXtreme controllers.

Syntax: apetest -t<1-9> or other command option.

Options:

-t<1-9> Run APE CPU Self Test

-n<#> Test iterations (0 = loop forever)

-l Load APE diagnostic firmware

-u Unload APE diagnostic firmware

-v Get APE diagnostic firmware version

-r Reset APE diagnostic interface

-d Display APE diagnostic result string

-G<#> Set APE GPIO output pin <0-6>

-g<#> Clear APE GPIO output pin <0-6>

page 167
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

11 ERROR MESSAGES
ERROR ID ERROR NO. ERROR STRING

NO_ERROR 0
ERR_IND_REG_ERR 1 Got XXXX @ XXXX. Expected XXXX
ERR_CHIP_RUNNING 2 Cannot perform task while chip is running
ERR_BAD_NIC 3 Invalid NIC device
ERR_READ_ONLY_CLEAR 4 Read only bit X got changed after writing zero at offset XXXX.
ERR_READ_ONLY_SET 5 Read only bit X got changed after writing one at offset XXXX
ERR_READ_WRITE_NOT_CLEAR 6 R/W bit X did not get cleared after writing zero at offset
XXXX
ERR_READ_WRITE_NOT_SET 7 R/W bit X did not get set after writing one at offset XXXX
ERR_BIST 8 BIST failed
ERR_INTERRUPT 9 Could not generate interrupt
CMD_ABORT 10 Aborted by user
ERR_DMA_TXDATA 11 Tx DMA:Got XXXX @ XXXX. Expected XXXX
ERR_DMA_RXDATA 12 Rx DMA:Got XXXX @ XXXX. Expected XXXX
ERR_TXDMA 13 Tx DMA failed
ERR_RXDMA 14 Rx DMA failed
ERR_MEM 15 Data error, got XXXX at XXXX, expected XXXX
ERR_MEM2 16 Second read error, got XXXX at XXXX, expected XXXX
ERR_EEP_WRITE 17 Failed writing NVRAM at XXXX
ERR_EEP_READ 18 Failed reading NVRAM at XXXX
ERR_EEP_DATA 19 NVRAM data error, got XXXX at XXXX, expected XXXX
ERR_FILE_OPEN 20 Cannot open file <filename>
ERR_BAD_CPU_CFG 21 Invalid CPU image file <filename>
ERR_IMAGE_SIZE 22 Invalid CPU image size XXXX
ERR_MALLOC 23 Cannot allocate memory for size XXXX
ERR_CPU_RESET 24 Cannot reset Rx | Tx CPU
ERR_CPU_NO_RESP 25 Rx | Tx CPU does not respond
ERR_CPU_TEST 26 Rx | Tx CPU test failed
ERR_DMA_RANGE 27 Invalid Test Address Range
Valid NIC address is XXXX- and exclude XXXX-XXXX
ERR_DMA_DATA 28 DMA:Got XXXX @ XXXX. Expected XXXX
SRAM data=XXXX @ XXXX
ERR_PHY_ID 29 Unsupported PhyId XXXX:XXXX
ERR_PHY_TOO_MANY_REG 30 Too many registers specified in the file, max is XXXX
ERR_VPD_WRITE 31 Cannot write to VPD address XXXX
ERR_VPD_DATA 32 VPD data error, got XXXX @ XXXX, expected XXXX
ERR_NO_LINK 33 No good link! Check Loopback plug
ERR_DATA_TX 34 Cannot TX Packet!
ERR_DATA_TX_MISSING 35 Requested to Tx XXXX. Only XXXX is transmitted
ERR_DATA_RX_MISSING 36 Expected XXXX packets. Only XXXX good packet(s) have been
received.
XXXX unknown packets have been received.
XXXX packets have been missing.
ERR_INVALID_TEST 37 XXXX is an invalid Test
ERR_EEPROM_CHECKSUM 38 NVRAM checksum error
ERR_READING_WOL_PXE 39 Error in reading WOL/PXE
ERR_READING_WOL_PXE 40 Error in writing WOL/PXE
ERR_NO_EXT_SRAM 41 No external memory detected
ERR_DMA_LEN 42 DMA buffer XXXX is too large, size must be less than XXXX
ERR_FILE_TOO_BIG 43 File size XXXX is too big, available space is XXXX
ERR_INVALID 44 Invalid <string>
ERR_WRITE 45 Failed writing XXXX to XXXX
CMD_QUIT 46
ERR_CPU_MEM_ERR 47 Rx | Tx CPU access error @ XXXX, expected XXXX but got XXXX
ERR_ENDIF 48
ERR_ROM_D_DATA 49 ROM disable error, data returned while disabled
ERR_CHIP_NOT_RUNNING 50 Cannot perform task while chip is not running. (need driver)
ERR_NO_REG_DEF 51 Cannot open register define file or content is bad
ERR_ASF_RST 52 ASF Reset bit did not self-cleared
ERR_ASF_ATTN_LOC 53 ATTN_LOC XXXX cannot be mapped to Rx | Tx CPU event bit XXXX
ERR_ASF_RST_VAL 54 Register is not cleared to zero after reset
ERR_ASF_PA_TIMER 55 Cannot start poll_ASF Timer
ERR_ASF_PA_CLEAR 56 poll_ASF bit did not get reset after acknowleged
ERR_ADF_NO_STAMP 57 Timestamp Counter is not counding
ERR_ADF_NO_TIMER 58 Timer is not working
ERR_ASF_EVENT 59 Cannot clear bit X in Rx | Tx CPU event register
ERR_EEP_FILESIZE 60 Invalid file size, expected XXXX but only can read
XXXX bytes
ERR_MAGIC_VALUE 61 Invalid magic value in XXXX, expected XXXX but found XXXX
ERR_EEP_FMT 62 Invalid manufacture revision, expected X but found X

page 168
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

ERR_EEP_BOOTVER 63 Invalid Boot Code revision, expected [Link] but found


[Link]
ERR_EEP_CANNOT_WRITE 64 Cannot write to NVRAM
ERR_EEP_CANNOT_READ 65 Cannot read from NVRAM
ERR_BAD_CHECKSUM 66 Invalid Checksum
ERR_BAD_MAGIC_VALUE 67 Invalid Magic Value
ERR_MAC 68 Invalid MAC address, expected XX-XX-XX-XX-XX-XX
ERR_BUS 69 Slot error, expected an UUT to be found at location XX:XX:00
ERR_SPEC_MEM 70 Adjacent memory has been corrupted while testing block
XXXX-XXXX
Got XXXX @ address XXXX. Expected XXXX
ERR_NOT_SUPPORT 71 The function is not Supported in this chip
ERR_BAD_CRC 72 Packets received with CRC error
ERR_MII_ERR_BITS_SET 73 MII error bits set: XXXX
ERR_INIT_MAC 74 CPU does not initialize MAC address register correctly
ERR_FW_FILE_FORMAT 75 Invalid firmware file format
ERR_RESET_TX_CPU 76 Resetting TX CPU Failed
ERR_RESET_RX_CPU 77 Resetting RX CPU Failed
ERR_INVALID_MAC_ADDR 78 Invalid MAC address
ERR_MAC_REG 79 Mac address registers are not initialized correctly
ERR_BOOTCHECKSUM 80 NVRAM Bootstrap checksum error
ERR_VPD_READONLY 81 Write operation changed VPD read only data from XXXX to XXXX
at XXXX
ERR_VPD_READ 82 Cannot read data from VPD address XXXX
ERR_MEM_READ 83 Memory read and compare error
ERR_MEM_WRITE 84 Memory write error (no longer in use)
ERR_PXE_PGM 85 PXE Programming Error
ERR_PXE_VFY 86 PXE Verification Error
ERR_EXT_MEM_EXE_TIMOUT 87 Cannot execute code from external memory, pc=XXXX
ERR_EXT_MEM_SIZE 88 External memory size detection error
ERR_RESET_TIMEOUT 89 Reset Time
ERR_MSI_ERR_NOTCLEAR 90 MSI Error bits are not cleared after reset
ERR_MSI_DATA 91 MSI expected XXXX, but read XXXX at XXXX
ERR_MEM_INIT 92 mem pool initialization failed
ERR_MEM_UNINIT 93 mem pool un-initialization failed
ERR_PCI_REGS_WIDTH 94 Read/Write PCI regs width XXXX affects wider than expected at
offset XXXX
ERR_LINK_STATUS 95 Link status error in auto-polling mode
ERR_PHY_INTERRUPT 96 Phy interrupt did not happen
ERR_EEP_BIT_BANG 97 EEprom test fails in bit-bang mode at address XXXXXXX
ERR_ROM_SIZE 98 ROM size error. Expected XXXX but read XXXX at ROM Bar (0x30)
register with XXXX written to ROM size reg.(0x88)
ERR_ROM_DATA 99 Data Error. Expected XXXX but read XXXX at XXXX
ERR_ROM_ENABLE 100 Expansion ROM Desired bit is not set after loading firmware
ERR_GPIO 101 GPIOXX Error, write=XXXX, read=XXXX
ERR_GPIO5704 102 Dev:XXXX Expected GPIO 0/1/2 = XXXX/XXXX/XXXX, but read as
XXXX/XXXX/XXXX
ERR_BIST_NOT_DONE 103 Bist test did not complete internally
ERR_BIST_DATA_MISCMP 104 Bist data miscompared at bit: XXXX out: XXXX exp: XXXX
ERR_CPU_NO_RESPONSE 105 No Response from firmware
ERR_CPU_ERR_CODE 106 Rx | Tx CPU returned result XXXX, key = XXXX
CMD_LOOP 107
CMD_SKIP 108
CMD_ELSE 109
CMD_ELSEIF 110
CMD_BREAK 111
CMD_ENDWHILE 112
ERR_BYTE 113 Byte access error: expected XX at XXXX but got XX
ERR_WORD 114 Wrd acc err: exp XXXX at XXXX but got XXXX (need [Link]
v2.3 or newer)
ERR_NO_LINK_DOWN 115 No link down found
ERR_MISMATCHED_DEVICEID 116 bootcode Image file belongs to XXXX family, does not match
with board XXXX
ERR_INVALID_DATA_SIZE 117 Invalid data size
ERR_MAC_ADDR_ENDED 118 Runs out of Mac Address
ERR_ILLEGAL_MAC_ADDR 119 Illegal Mac Address
ERR_BIST_DATA_INVALID 120 Invalid bist data from buffer at XXXX
ERR_INVALID_BOND_ID 121 Invalid bond id XXXX
ERR_BAD_CPU_RESET 122 CPU reset failed, register 5034 is XXXX
ERR_INCORRECT_VERSION 123 Incorrect version
ERR_MISMATCH_CFG_VERSION 124 Mismatched CFG and FW Image version

ERR_NOT_SUPP_CFG_BW 125 Current ASF_T_VERSION is not backward compatible


ERR_POST_1G_LB 126 1G Tx/Rx Lines Have A Short/Open

page 169
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

ERR_DRIVER 127 Unsupported driver version [Link] (need bcm57diag v9.0.0 or


tg3d 3.66l or newer)
ERR_TXDMA_OVERFLOW 128 TxDMA Overflow
ERR_RXDMA_OVERFLOW 129 RxDMA Overflow
ERR_DRIVER_BAD_STATUS 130 Driver returned error status=XXXX on ioctl=X
ERR_INVALID_HANDLE 131 Invalid Handle
ERR_SOCKET 132 Socket open error XXXX
ERR_SIOCGIFINDEX 133 ioctl(): SIOCGIFINDEX failed
ERR_BIND 134 bind() failed:
ERR_SETSOCKOPT 135 setsockopt() failed:XXXX
ERR_FCNTL 136 fcntl() failed:XXXX
ERR_SEND 137 send() failed (cnt=XXXX): XXXX
ERR_RECEIVE 138 recvfrom() failed (cnt=XXXX): XXXX
ERR_FALSE_CARRIER 139 Error! False Carrier detected during the test
ERR_INV_OPT 140 Invalid Options
ERR_INV_DEV 141 Found Rv = XXXX, Expected Rv = XXXX due to -ckdev
value
ERR_IRQ 142 Invalid IRQ XX
ERR_TIMEOUT 143 Timeout
ERR_PKT_DATA 144 Packet data error at offset XXXX, expected XX but recevied
XX
ERR_MAC_ZERO 145 Zero Mac Address in Mac Register
ERR_MAC_MIS_REG 146 Mac Address MisMatch: Got XX-XX-XX-XX-XX-XX.
ERR_CPU_ACC 147 Rx | Tx CPU failed on XXXX bit access to address XXXX
ERR_CPU_MEM 148 Rx | Tx CPU failed on memory pattern XXXX at address XXXX
ERR_CPU_INSTR 149 Rx | Tx CPU Instruction test failed
ERR_BUS_LINK 150 PCI-E Bus Link Error
ERR_ASF_FILE_VER 151 ASF File versions Error
ERR_ASF_VS_DEV 152 ASF VS Device Error
ERR_MISMATCHED_DEVICEID_1 153 bootcode Image file belongs to unknown family, does not
match with board XXXX
ERR_MISMATCHED_DEVICEID_2 154 bootcode Image file belongs to XXXX family, does not match
with unknown board
ERR_CPU_FETCH 155 CPU Fetch Test Error: Breakpoint reads XXXX
ERR_UMPLB 156 UMP loopback failed, Total Good packet XXXX
ERR_UMPCTRL 157 Error: UMPCtrl 0x5F0 = XXXX
ERR_REG_TABLE 158 Error: Unable to create Reg Table
ERR_FW_IMAGE_SIZE 159 Error: Firmware image size (XXXX) larger than NVRAM size
(XXXX)
ERR_MISS_PXE 160 Error: PXE firmware cannot be found in NVRAM
ERR_MISS_ASF 161 Error: ASF firmware cannot be found in NVRAM
ERR_NVRAM_DIR 162 Error: NVRAM Directory
ERR_MISS_UMP 163 Error: UMP firmware cannot be found in NVRAM
ERR_CPU_MEM2 164 Rx | Tx CPU memory error @ XXXX, expected XXXX but got XXXX
ERR_SERIAL1 165 PCIE Serial Device Number Capability Not Found.
ERR_SERIAL2 166 PCIE Serial Device Number Match Failure.
ERR_POWER1 167 PCIE Power Budget Capability Not Found.
ERR_POWER2 168 PCIE Power Budget Error (ad=XXXX, saw=XXXX, exp=XXXX).
ERR_UMP_VS_DEV 169 UMP VS Device Error
ERR_HM_BR_LANES 170 M Bridge Lanes Error: XXXX PCI-E lanes are actually linked
and running, expected XXXX.
ERR_BRIDGE 171 Invalid bridge.
ERR_NO_LINK10 172 No good link at 10 Mbits/s! Check Loopback plug
ERR_NO_LINK100 173 No good link at 100 Mbits/s! Check Loopback plug
ERR_NO_LINK1000 174 No good link at 1000 Mbits/s! Check Loopback plug
ERR_DMA_SHASTA 175 Failed! Saw=XXXX @ XXXX, Exp=XXXX from XXXX
ERR_SECFG_CONT 176 SECFG Config Error. Line XXXX
ERR_SECFG_INVALID 177 Invalid Argument in SECFG Config File at Line XXXX
ERR_NV_SELFBOOT 178 NVRAM is SELFBOOT
ERR_PART_NUM 179 Error Part Number Check Failed
ERR_UMPECHO 180 UMP Echo - Debug Mode
ERR_IMAGE_CHECKSUM 181 Firmware image checksum error
ERR_INVALID_SMB 182 Invalid SMB Address
ERR_LOM_CFG 183 LOM CONF Bit mismatch in Reg 178 and Reg 7C04
ERR_ISCSI_PGM 184 iSCSI Programming Error
ERR_BAD_CHIP_REV 185 Invalid Chip Rev.
ERR_NO_CPU 186 Device has no internal CPU
ERR_BAD_PARITY_VALUE 187 Invalid Parity.
ERR_BAD_VPD_CHKSUM 188 Invalid VPD Checksum
ERR_ESWITCH_CTRL_TO 189 Halting E Switch Ctrl time out. XXXX
ERR_ESWITCH_EVENT 190 ESWITCH event not set. XXXX
ERR_ESWITCH_TO 191 E Switch time out. XXXX
ERR_ESWITCH_ARBIT_TO 192 Halting E Switch Ctrl Arbitor time out. XXXX
ERR_ESWITCH_INTR 193 ESWITCH interrupt not set. XXXX
ERR_ESWITCH_STATUS 194 ESWITCH status word not set. XXXX

page 170
Broadcom Confidential and Proprietary
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide

ERR_SADB_ENTRY 195 SADB Entry error at SA Indx XXXX with pattern <string>
ERR_SADB_CORRUPT 196 SADB Data corrupted: Got XXXX at SADB index XXXX word index
XXXX. Expected = XXXX
ERR_SADB_DEL_ALL 197 SADB delete all error
ERR_SADB_DEL 198 SADB delete SA index XXXX error
ERR_SADB_INTR 199 SADB interrupt not set. <string> index XXXX
ERR_SADB_ENTRY_TEST 200 SADB Entry Test error at SA Indx XXXX
ERR_SHA1_NOT_SUPPORTED 201 SHA1 not supported
ERR_DIR_CHECKSUM, 202 Directory Checksum Error
ERR_APE_REGISTER_RANGE, 203 Invalid APE register range
ERR_APE_MUTEX_RELEASE, 204 Can not release APE Mutex Grant register
ERR_APE_MUTEX_REQUEST_GRANT 205 APE Mutex register was not granted (Mutex registers
0xXXXX=XXXX; 0xXXXX=XXXX).
ERR_APE_TIMER_RESET 206 APE Timer reset value error, XXXX.
ERR_APE_TIMER_RUN 207 APE Timer counting error, XXXX.
ERR_APECPU_LOAD 208 APE firmware load error: XXXX
ERR_APECPU_TIMEOUT 209 APE CPU test timed out: XXXX
ERR_APECPU_MEM 210 APE CPU Memory Test error: XXXX
ERR_APECPU_ETH 211 APE CPU Ethernet Test error: XXXX
ERR_APECPU_SMB 212 APE CPU SMBus Test error: XXXX
ERR_APECPU_GPIO 213 APE CPU GPIO Test error: XXXX
ERR_APECPU_EVENT 214 APE CPU Event Test error: XXXX
ERR_APECPU_MUTEX 215 APE CPU Mutex Test error: XXXX
ERR_APECPU_TIMER 216 APE CPU Timer Test error: XXXX
ERR_APECPU_GRC 217 APE CPU GRC Test error: XXXX
ERR_POST_100_LB 218 Tx/Rx Lines Have A Short/Open
ERR_DATA_TX_MISSING_IPSEC 219 Requested Tx of XXXX IPSEC Pkt(s) with Cipher <string>.
Only XXXX transmitted
ERR_DATA_RX_MISSING_IPSEC 220 Expected Rx of XXXX IPSEC Pkt(s) with Cipher <string>.
Only XXXX received
ERR_RX_HW_CRYPTO_DONE_CNT 221 Got HW_CRYPTO_DONE_CNT = XXXX, Expected XXXX
ERR_USER_BLOCK_NOT_AVAILABLE 222 User block not available
ERR_CPU_MUTEX_ERROR 223 Rx | Tx CPU test APE Mutex error, test XXXX
ERR_CPU_REG_ERROR 224 Rx | Tx CPU test APE reg error, test XXXX
ERR_CPU_BIN_FILE_MISMATCH 225 Soledad Rev B0 and up should use [Link] version 4.0 or
up.
ERR_USB_NOT_DETECTED 226 USB device was not detected. Please check cable
connection.
ERR_USB_DATA_ERROR 227 USB device error during data transfer.
ERR_SELFBOOTII_BAD_ECC, 228 SelfbootII CPD #XXXX ECC got corrupted.
ERR_SELFBOOTII_BAD_CPD, 229 SelfbootII CPD #XXXX got corrupted.
ERR_SELFBOOTII_FULL, 230 OTP is full.
ERR_SELFBOOTII_EMPTY, 231 OTP is empty.
ERR_SELFBOOTII_OTP_CORRUPTED 232 Dismatched when compared to file <filename>

page 171
Broadcom Confidential and Proprietary

You might also like