SolaX

EV Charger Parallel Function


SolaX X1/X3 EVC
Introduction

For the users who like to install two Solax EV chargers


under same circuit, we develop parallel function to
distinguish them as primary charger and secondary charger.
The primary charger takes the responsibility to collect PV
feed-in information and grid energy consumption information
together and to allocate the PV energy and remained load
capacity for the system according to allocation ratio. The
secondary charger’s work mode setting will be copied from
primary charger. This function only apply for two same model
chargers (same version, same power rating).
Communication connection

• Communicate with inverter

Use two core cable to connect Primary


charger’s A1B1 or RJ45 port to inverter’s COM
port (For different inverter’s connection ,
please refer to Solax Inverter & EV charger
connection and setting guide).

Use two core cable to connect primary


charger’s A2B2 to secondary charger’s A1B1.
Communication connection

• Connect with CT

Connect CT to primary charger’s RJ45 port (For


connection instruction, please refer to the
manual).

Use two core cable to connect primary


charger’s A2B2 to secondary charger’s A1B1.
Setting:
Do the APP setting on primary charger, no need to do setting on secondary charger.
• Enable Parallel function in advanced setting.
• Choose power allocation ratio, the default is 1:1, and supported ratio is 1:1, 1:2, 2:1. This feature is to allocate the PV energy and remaining
load capacity for the two charger if user needs.

Charge Power (kW)

• Set the main breaker value as needed on primary charger.


Work principle:
• When primary charger or secondary charger works alone, they can use full PV energy and remaining load capacity.
• When primary charger and secondary charger work together, the primary charger will allocate the PV energy and remaining
load capacity for two chargers.
(Note: the allocation ratio will not be that accurate due the allocated energy unbalance, it is to keep the system work stable, so it
is normal.)

Compatibility (no change):


On-grid inverter: X3-PRO G2, X3-MIC G2, X1-Mini G3/G4, X1-Boost G3/G4
Hybrid inverter: X1-Hybrid/Fit G4, X3-Hybrid/Fit G4

Note:
this function is available for home edition EV charger. It will be ready for new commercial edition EV charger soon.