Storage

• Data storage: also has issues of availability and fault tolerance


• Different methods are available for making sure shared data and applications
are never lost or irretrievable
RAID (Redundant Array of Independent [or
Inexpensive] Disks)
• Collection of disks
• Provide shared data, application fault tolerance
• Disk array (drive)
• Group of hard disks
• RAID drive (RAID array)
• Collection of disks working in a RAID configuration
• Single logical drive
RAID (cont’d.)
• Hardware RAID
• Set of disks, separate disk controller
• RAID array managed exclusively by RAID disk controller
• Attached to server through server’s controller interface
• Software RAID
• Software implements, controls RAID techniques
• Any hard disk type
• Less expensive (no controller, disk array)
• Performance rivals hardware RAID
RAID (cont’d.)
• RAID Level 0 - Disk Striping
• Simple RAID implementation
• Data written in 64-KB blocks equally across all disks
• Not fault-tolerant
• Does not provide true redundancy
• Best RAID performance (in this chapter)
• Uses multiple disk controllers
RAID (cont’d.)

Figure 14-6 RAID level 0 - disk striping


RAID (cont’d.)
• RAID Level 1- Disk Mirroring
• Disk mirroring provides redundancy
• Data from one disk copied automatically to another disk
• Advantages
• Simplicity, automatic and complete data redundancy
• Disadvantages
• Cost of two disks
• CPU usage because software does the mirroring
RAID (cont’d.)
• Disk duplexing
• Similar to disk mirroring
• Data continually copied from one disk to another
• Separate disk controller used for each disk
• Provides added fault tolerance
RAID (cont’d.)

Figure 14-7 RAID level 1 - disk mirroring


RAID (cont’d.)
• RAID Level 3 - Disk Striping with Parity ECC
• ECC (error correction code)
• Algorithm to detect, correct errors
• Known as parity error correction code
• Parity
• Mechanism to verify data integrity
• Number of bits in byte sum to odd, even number
• Use either even parity, odd parity, not both
Table 14-1 The use of parity bits to achieve parity

• RAID Level 3 - Disk Striping with Parity ECC (cont’d.)


• Parity tracks data integrity
• Not data type, protocol, transmission method, file size
• Parity error checking
• Process of comparing data parity
Figure 14-8 RAID level 3 - disk striping with parity ECC

• RAID Level 3 - Disk Striping with Parity ECC (cont’d.)


• Advantage
• High data transfer rate
• Disadvantage
• Parity information appears on single disk
RAID (cont’d.)
• RAID Level 5 - Disk Striping with Distributed Parity
• Most popular data storage technique
• Data written in small blocks across several disks
• Parity error checking information distributed among disks
• Advantages over RAID level 3
• Writes data more rapidly
• Uses several disks for parity information
• Disk replacement causes little interruption
• Controlling software regenerates failed file parts
RAID (cont’d.)

Figure 14-9 RAID level 5 - disk striping with distributed parity


RAID (cont’d.)
• RAID Level 5 - Disk Striping with Distributed Parity
• Hot spare (failover component)
• Array disk, partition used only when one RAID disk fails
• See link Ch 14i
• Cold spare (hot swappable component)
• Duplicate component
• Not installed
NAS (Network Attached Storage)
• Specialized storage device, storage device group
• Provides centralized fault-tolerant data storage
• Difference from RAID
• Maintains own interface to LAN
NAS (cont’d.)
• Advantages
• NAS device contains own file system
• Optimized for saving, serving files
• Reads, writes fast
• Easily expandable
• No service interruption
• Disadvantage
• No direct communication with network clients
• Use
• Enterprises requiring fault tolerance, fast data access
NAS (cont’d.)

Figure 14-10 Network attached storage on a LAN


SANs (Storage Area Networks)
• Distinct networks of storage devices
• Communicate directly
• With each other, other networks
• Multiple storage devices
• Connected to multiple, identical servers
SANs (cont’d.)
• Advantages
• Fault tolerant
• Fast
• Special transmission method
• Special protocols, like Fibre Channel
• Despite the name, Fibre Channel can run over both copper and fiber media (link Ch 14k,
14l)
• SAN can be installed in location separate from LAN served
• Provides added fault tolerance
• Highly scalable
• Faster, more efficient method of writing data
SANs (cont’d.)
• Drawbacks
• High cost
• Small SAN: $100,000
• Large SAN: several million dollars
• More complex than NAS, RAID
• Training, administration efforts required
• Use
• Environments with huge data quantities requiring quick availability
Figure 14-11 A storage area network