100% found this document useful (2 votes)
157 views

A10dfr e

This document describes the A10V(S)O pressure/flow control DFR(1), including: 1) It has a pressure port B for pressure control and a flow control port FR that controls differential pressure. 2) Diagrams show the circuit and function, including an adjustable orifice, mobile valve block, pressure port, and damping orifice. 3) Adjustment procedures are described for the pressure control DR and flow control FR ports. Measurements are taken at various ports to set the controls to the desired pressure and differential pressure levels.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
157 views

A10dfr e

This document describes the A10V(S)O pressure/flow control DFR(1), including: 1) It has a pressure port B for pressure control and a flow control port FR that controls differential pressure. 2) Diagrams show the circuit and function, including an adjustable orifice, mobile valve block, pressure port, and damping orifice. 3) Adjustment procedures are described for the pressure control DR and flow control FR ports. Measurements are taken at various ports to set the controls to the desired pressure and differential pressure levels.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 14

A10V(S)O Pressure/Flow control DFR(1)

Ports

Pressure port B Pressure control DR

Standard setting:
Case drain port L
A10VODFR/31: 280 bar
A10VODFR/52: 250 bar

Flow control FR

p = 10 - 22 bar)

Standard setting:
p = 14 bar
X - Pilot pressure port

Suction port S
(viewed A10VO, BR 31, clockwise)

A10 146.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Circuit diagram

Adjustable orifice, X - port


res.
Flow control
Mobile valve block
(Standard:
(not included in
p = 14 bar);
supply)
FR
Decompression
orifice

DR Pressure port

Damping orifice

Control piston

(Circuit diagram
viewed for A10VO,
series 31) Counter balance piston and mechanical spring

A10 146.2.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Function and circuit diagram
Orifice res. Mobile LS - pilot pressure
valve block

FR

DR

DR - axis

FR - axis

A10 146.3.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
p - control characteristic f (x) = (px, Vg)

High pressure: p HD Simulated load


pressure: p X

p = 15 bar

A10 VO 74 DFR(1)

Mode of experimental procedure:

n = 1500 rpm
p = 15 bar
Stand by = 20 bar
pHD
px
X
DFR1

A10 146.4.d/VST6 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Decompression orifice and damping orifice
DFR with decompression orifice:
(DFR: Standard:  0,35 mm)
(DFR1: closed, without drilling)
X

FR
FR - axis

DR
DR - axis

Damping orifice DR - FR
(Standard:  0,6 mm,
Slit in longitudinal direction: orifice opened
Slit in cross direction : orifice closed, SO 74)

A10 146.5.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Measurement of high pressure

Attention:

The mini - measurement


connection have to be
shortened according to the
original lenght of the plug
(reach of a screw 7 mm).

Measurement high pressure:

At this particular spot, the


existing plugs (M8 x 1) can
be replaced by mini measure-
ment connections

A10 146.7.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Adjustment for pressure- res. flow control
Adjustment of pressure control Adjustment of
flow control:

„Stand - by“ pressure


measurement

or

Differential pressure
measurement with
swivel angle !

Valve axis: Valve axis:


Pressure control Flow control

A10 146.8.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Adjustment of pressure control DR

Procedure:
 FR - flow control blocked !
 High pressure line closed !
 Adjusting of DR pressure control X
with setting value !
FR
Measuring - point 1: High pressure
(measurable at plug of DR valve axis)
DR
Adjustment DR : each rotation
app. 50 bar !

- 50 bar
+ 50 bar

A10 146.9.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Adjustment of flow control FR

1. „Stand by“ pressure measurement:


Procedure:

 X - port unloaded to tank !


X
 close high pressure port !
Standard adjustment FR p = 14 bar
FR
(When port X is unloaded to tank, a zero
stroke pressure of p = 16 ± 1 bar „stand by“
results. DR
Measuring - point 1: zero stroke pressure
(measurable at plug of valve axis)
- 16 bar
+ 16 bar

A10 146.10.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Adjustment of flow control FR

2. Possibility: Differential pressure measurement :

X
Measuring - point 1: load pressure
corresponding to pressure of port X !
( LS - signal )
FR

Measuring - point 2: High pressure


DR

(measureable at plug of valve axis)

- 16 bar
+ 16 bar

A10 146.11.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Differences between DFR and DFR1

DFR - design
With decompression orifice !
(DFR: Standard:  0,35 mm
glued in place, fastened with Loctide)

DFR1 - design
Without decompression orifice !
(DFR1: closed, without drilling)

A10 146.12.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Usage DFR(1) for series 31 and 52 !

A10 - series 31: A10 - series 52:


DFR(1) - without return line DFR(1) - with return line orifice
orifice ! (Standard:  2,2 mm !)

FR

DR
Special design (Stabilization):
SO 116: Return line orifice  1,3 mm
SO 229: Return line orifice  1,5 mm
SO 231: Return line orifice  2,2 mm
SO 277: Return line orifice  1,0 mm
SO 381: Return line orifice  0,8 mm
SO 617: Return line orifice  0,6 mm

A10 146.13.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Mounting of DFR(1) control (series 31)

Mounting of DFR(1) - control (A10V(S)O series 31) depends on


direction of rotation (Direction of rotation by view on drive shaft) !

A10 146.14.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Different designs

DFR(1) for A10V(S)O DFR(1) for A10V(S)O


Size 18 - 100 Size 140

Standard design ! Design in sandwich - plate


design !

A10 146.15.e/VST6/H 01.AK

You might also like