Steel Connection Design Class

The document discusses the design of steel connections for a reinforced concrete structure. It covers estimating beam depths and secondary beam spacing, designing longitudinal and shear reinforcement in beams. It also discusses designing reinforced concrete columns, composite beams, and several types of steel connections including beam to column, beam to beam, base plates, beam splices, and column splices. Design requirements for various connections like minimum hole spacing are also summarized.

Uploaded by

John Hammer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
169 views32 pages

Steel Connection Design Class

The document discusses the design of steel connections for a reinforced concrete structure. It covers estimating beam depths and secondary beam spacing, designing longitudinal and shear reinforcement in beams. It also discusses designing reinforced concrete columns, composite beams, and several types of steel connections including beam to column, beam to beam, base plates, beam splices, and column splices. Design requirements for various connections like minimum hole spacing are also summarized.

Uploaded by

John Hammer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 32

Steel Connection Design Class

Reinforcing Bars Yield Strength and Tensile strength


Concrete Cover
Bar Number ,diameter , areas and weight of standard bar
Beam Depth Estimation
Beam Span = 20 ft
Span depth ratio = L/16 (Simply supported)
=( L x 12 )/ 16 = 0.75 L
Minimum Beam Depth = 0.75x20 = 15 ( Take 16”)
Try B12x16
Steel Headed Stud Anchors (Shear Stud )
Steel Headed Stud Anchors (Shear Stud )
Slenderness Ratio
KL/r < 200 ( Compression)
KL/r < 300 ( Tension)

Secondary Beam Spacing Estimation


Deck weight = 2.75 psf
Concrete wt = 49 psf (5 1/2” )
Live Load = 40 psf
SDL = 20 psf
Total Load = 111.75 psf
Max Allowable span = 7 ft ( 119 psf )
Wall Load on Ground Beam

Unit Wt of 4 ½” tk brick wall = 50 psf


Wall Load
Assume Beam Depth = 1 ft
11x50 = 550 lb/ft
Floor ht = 12 ft
Wall ht = (12-1) = 11 ft
Live Load and Super Dead
Load

Live Load = 40 psf


SDL = 20 psf
Reinforced Concrete Beam Design (Longitudinal Reinforcing )

Longitudinal Reinforcing

Top Steel

Bottom Steel

Left Mid Right

As min = (200/Fy ) bw d = (200/50000) x 12 x (16-2.5) = 0.648 in²


Take 16mm ø, As = 0.312 in2
Eg 0.648/0.312 = 2.07 ( Take 3 nos )
Reinforced Concrete Beam Design ( Torsion Reinforcing)

Torsion Reinforcing

Torsion Reinforcing
If H>18” , Top = Ast/3 If H≤18” , Top = Ast/2

Mid = Ast/3
Bottom = Ast/2
Bottom = Ast/3
Reinforced Concrete Beam Design ( Shear+Torsion Reinforcing)

Shear+Torsion Reinforcing (in²/in )

Shear+Torsion Reinforcing
Assume 10mmØ , Av = 0.11 in²
Eg. Av/s + 2 At/s = 0.023 in²/in
S = 2 Av / (Av/s + 2 At/s ) = (2x0.11)/0.023 =9.5 in
Reinforced Concrete Design Requirement
Reinforced Concrete Design Requirement
Reinforced Concrete Design Requirement
Reinforced Concrete Column Design

C 12”x 12”
As = λ b d = 0.01 x 12 x 12 = 1.44 in²
Use 16mmØ , As = 0.31 in²
No of bar = 1.44/0.31 = 4.65 ( Take 6 nos )
6-d16 mm
Deflection Limits From IBC
PMM ratio for steel
PMM ratio for steel
Composite Beam Design
Connection Design requirement

Minimum Spacing
The distance between centers of standard, oversized or slotted holes shall not be less
than 2 2/3 times the nominal diameter, d, of the fastener; a distance of 3d is preferred.
Connection Design requirement
Sign Convention From Etabs to Ram Connection
Etabs Ram Connection
Clockwise = (-ve) Clockwise = (-ve)
Counterclockwise = (+ve) Counterclockwise = (+ve)
Sign Convention From Etabs to Ram Connection
Etabs Ram Connection
Downward = (-ve) Downward = (+ve)
Upward = (+ve) Upward = (-ve)
Sign Convention From Etabs to Ram Connection
Etabs Ram Connection
Compression = (-ve) Compression = (-ve)
Tension = (+ve) Tension = (+ve)
Beam-Column Flange (Moment Connection)

Column = H200x200x8x12 Beam = H250x125x6x9


M33 = -32 k-ft
V2 = 11 k
A = -0.343 k
Beam-Column Web (Moment Connection)

Column = H200x200x8x12 Beam = H300x150x6.5x9


M33 = -4.6 k-ft
V2 = 5.166 k
A = -0.191 k
Beam-Beam (Shear Connection)

Beam = H250x125x6x9 Beam = H250x125x6x9


V2 = 10.321 k
A = 0.111 k
Base Plate Design (Pin-Based Connection)

Column = H200x200x8x12 RC Column = 12”x12”


V2 = 2.9 k V3 = 0.527 k
A = -16.4 k
Beam Splice
Beam Spice should be located 1/6 of the length of beam.
Beam = H300x150x6.5x9
M33 = 8.25 k V2 = 4 k
A = -0.2 k
Column Splice
Column splice should be located at 4ft above the floor.
Beam = H200x200x8x12
M33 = 11. 6k M22 = 2.11 k
A = -16.2 k V2 =3k