Air & Draft System: July 10, 2011 PMI Revision 00 1

The document discusses the air and draft systems used in boilers. It describes the various fans used, including primary air fans, forced draft fans, and induced draft fans. The primary functions of the draft system are to provide combustion air and evacuate flue gases. It explains the need for draft to overcome flow losses and discusses how fan type is selected based on air flow needs. Key points covered include the arrangement of boiler auxiliaries, primary and secondary air systems, components of the different fan types, and the impact of variable speed drives on fan performance.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
98 views

Air & Draft System: July 10, 2011 PMI Revision 00 1

The document discusses the air and draft systems used in boilers. It describes the various fans used, including primary air fans, forced draft fans, and induced draft fans. The primary functions of the draft system are to provide combustion air and evacuate flue gases. It explains the need for draft to overcome flow losses and discusses how fan type is selected based on air flow needs. Key points covered include the arrangement of boiler auxiliaries, primary and secondary air systems, components of the different fan types, and the impact of variable speed drives on fan performance.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 40

Air & Draft system

July 10, 2011 PMI Revision 00 1

Presentation Plan
Various auxiliary equipments in a boiler Need for Draft System Primary and secondary air system in Boiler and their fans Other fans in a boiler Basic of fans: Fan Types and selection Fan laws and factors affecting fan performance Performance curves

July 10, 2011

PMI Revision 00

Arrangement of Boiler Auxiliaries

July 10, 2011

PMI Revision 00

Need of Draft System

Combustion Air

Boiler

Flue Gases

Air needed for combustion Flue are needed to be evacuated Losses due to flow need to be overcome
July 10, 2011 PMI Revision 00 4

How to select a fan


Air or Gas flow -Kg/hr Density (function of temperature and pressure) System, resistance (losses) Major Fans in Boiler Draft System PA Fans FD Fans ID Fans

July 10, 2011

PMI Revision 00

PRIMARY AIR/MILL SEAL AIR SYSTEM


Ambient air is drawn into the primary air ducting by two 50% duty, motor driven axial reaction fans. Air discharging from each fan is divided into two parts, one passes first through a air preheater then through a gate into the P.A bus duct. The second goes to the cold air duct. The mix of both is used to carry the pulverized coal to the boiler.
July 10, 2011 PMI Revision 00 6

Components of PA Fan
Suction Bend With volume Measurement instruments Fan housing with Guide Vanes Main Bearings (Anti Friction) Rotor with impeller with adjustable blade with pitch control Guide vane housing with guide vanes Diffuser with pressure measurement instruments
July 10, 2011 PMI Revision 00 7

SECONDARY AIR SYSTEM


Ambient air is drawn into the secondary air system by two 50% duty, motor driven axial reaction forced draft fans with variable pitch control. Air discharging from each fan passes first through a air preheated then through a isolating damper into the secondary air bust duct. The cross over duct extends around to each side of the boiler furnace to form two secondary air to burner ducts. At the sides of the furnace, the ducts split to supply air to two corners. Then split again to supply air to each of nineteen burner/air nozzle elevations in the burner box.

July 10, 2011

PMI Revision 00

Burner Box Dampers


Coal/Air Dampers Secondary Air Dampers Oil/Secondary Air Dampers Bottom Tier Secondary Air Damper Over Fire Damper

July 10, 2011

PMI Revision 00

Primary and Secondary air System in the Boiler

July 10, 2011

PMI Revision 00

10

Axial Fans FD Application

July 10, 2011

PMI Revision 00

11

Induced Draft System


There are three induced draught fans per boiler, two operating and one standby In 500 MW fans are single-stage, doubleinlet centrifugal fans. Principal fan elements of the fan are: Housing Inlet dampers Rotor with Bearing Shaft Seal
July 10, 2011 PMI Revision 00 12

ID Fan
The rotor consists of shaft and assembled impeller and runs in two sleeve bearings that are arranged outside of the housing. The impeller consists of a centre disc and two cover discs that are reinforced by forged rings. The bent blades are welded into position between the impeller discs. The blades are protected by screwed - on wear plates. The shaft is of hollow design. The fan shaft has been rated so that max. operating speed is below the critical speed. Impeller and shaft are connected by means of a flange. This screwing is protected by wear plates. The fan housing is sealed by means of two-part labyrinth seals. Bearings are lubricated with oil.

July 10, 2011

PMI Revision 00

13

Other Fans in The System


Ignitor Air Fan: Provide combustion air to the ignitors. Take suction air from the atmosphere and supplies air to the ignitor wind box. Scanner Air Fan: Supplies cooling air to flame scanners. Normally there are two fans taking suction from FD Fan discharge duct. Mill Seal air fan: Seal air fans provide air for the sealing of Mill bearing. Suction is from cold Primary air and pressure is boosted up to maintain the differential pressure

July 10, 2011

PMI Revision 00

14

AIR AND FLUE GAS PATH TYPICAL 500 MW BOILER


TO MILLS

PAPH-A

PRIMARY

ECO BYPASS

SCAPH-A

PA FAN -A

TO ESP

SAPH-A

AA205

AA203

SCAPH-A SECOND

AEROFOIL

AA202

AA201

HORIZONTAL S.H

ECONOMISER -1

DIVISION PANELETTE S.H

ECONOMISER -2

ECONOMISER-3

SA HDR

AA204

FD FAN -B

PLATEN S.H

HOT

COMBUSTION CHAMBER

RE HEATER

HOT PA HDR

AA204

AA201

SAPH-B

AA205

AA203
SCAPH-B SECOND

AA202 FD FAN-A

AEROFOIL

COLD SEC. AIR COLD PRIM AIR HOT PRIMARY AIR HOT SEC. AIR FLUE GAS PNEUMATICALLY O/P KNIFE EDGE GATE MOTOR O/P LOUVER DAMPER PNEUMATICALLY O/P LOUVER DAMPER

BIPLANE DAMPER DIVERTER DAMPER

ECO BYPASS

TO ESP

TO MILLS PA FAN -A

July 10, 2011 MOTOR O/P GATE

PMI Revision 00

PAPH-B

SCAPH-B

PRIMARY

15

Scheme of Air and Gas Path

July 10, 2011

PMI Revision 00

16

ID Fan at Location

July 10, 2011

PMI Revision 00

17

Variation of Pressure in Boiler


Furnace P ressure At Various P oints in B oiler
250 200 150 100 50 Furnace Pressure 0 1 -50 -100 -150 -200 -250 -300 Points in Boiler 2 3 4 5 6 7 8 9 10 11 12 13 14

1FD Fan Inlet 2FD Fan Outlet 3Airheater Inlet 4Airheater Outlet 5Windbox Pressure 6Furnace 7Superheater Platen Inlet

8Reheater Inlet 9LTSH Inlet 10Economiser Inlet 11Airheater Inlet 12E.P. Inlet 13I.D. Fan Inlet

July 10, 2011

PMI Revision 00

14I.D. Fan Outlet

18

Basics on Fans

July 10, 2011

19

Difference between fans, blowers and compressors


As per ASME the specific pressure, i.e, the ratio of the discharge pressure over the suction pressure is used for defining the fans, blowers and compressors as highlighted below :

Equipment Fans Blowers Compressors


July 10, 2011

Specific Ratio Up to 1.11 1.11 to 1.20 more than 1.20

Pressure rise (mmWg) 1136 1136 2066 20

PMI Revision 00

Typical centrifugal fan operation

July 10, 2011

PMI Revision 00

21

Fan types

Centrifugal fan
July 10, 2011 PMI Revision 00

Axial fan
22

Centrifugal Fan: Types

Paddle Blade (Radial blade)

Forward Curved (Multi vane)

Backward Curved

July 10, 2011

PMI Revision 00

23

Axial Flow Fan: Types


Tube Axial Vane Axial Propeller

July 10, 2011

PMI Revision 00

24

Fan Types and Efficiencies


Peak Efficiency Range Airfoil, backwardly curved/inclined 79-83 Modified radial 72-79 Redial 69-75 Pressure blower 58-68 Forwardly curved 60-65 Axial fan vanaxial 78-85 Tubeaxial 67-72 Propeller 45-50 Centrifugal Fans
July 10, 2011 PMI Revision 00 25

Axial -flow Fans Type Prope ller Characteristics Low pressure, high flow, low efficiency, peak efficiency close to point of free air delivery Medium pressure, high flow, higher effici ency than propeller type, dip in pressure -flow curve before peak pressure point. High pressure, medium flow, dip in pressure -flow curve, use of guide vanes improves efficiency Typical Applications Aircircul ation, ventilation, exhaust HVAC, drying ovens, exhaust systems Type Radial

Centrifugal Fans Characteristics High pressure, medium flow, efficiency close to tube-axial fans, power increases continuously Medium pressure, high flow, dip in pressure curve, efficiency higher than radial fans, power rises continuously High pressure, high flow, high efficiency, power reduces as flow increases beyond point of highest efficiency Same as backward curved type, highest efficiency Typical Applications Various industrial applications, suitable for dust laden, moist air/gases Low p ressure HVAC, packaged units, suitable for clean and dust laden air / gases

Tubeaxial

Forward curved blades

Vane axial

High pressure applications including HVAC systems, exhausts

Backward curved blades

HVAC, various industrial applications, forced draft fans, etc.

Airfoil type
July 10, 2011 PMI Revision 00

Same as backward curved, but for clean air applications


26

System characteristic curve

July 10, 2011

PMI Revision 00

27

July 10, 2011

PMI Revision 00

28

System curve

July 10, 2011

PMI Revision 00

29

Fan Laws
Flow ? Speed Pressure ? (Speed)2 Power ? (Speed)3

Q1 N 1 = Q2 N 2

SP1 N 1 = SP 2 N 2

kW 1 N 1 = kW 2 N 2
Varying the RPM by 10% decreases or increases the power requirement by 27%.
30

Varying the RPM by 10% Varying the RPM by 10% decreases or increases air decreases or increases the delivery by 10%. static pressure by 19%.

Where Q flow, SP Static Pressure, kW Power and N speed (RPM)


July 10, 2011 PMI Revision 00

Fan static pressure


Fan Static Pressure SP = SP (Fanoutlet) SP (Faninlet)
SP (Fanoutlet) Static pressure at fan outlet, mm WC SP (Faninlet) Static pressure at fan inlet, mm WC

SP = 0.05 (-10) = 10.05 mm W.C.


July 10, 2011 PMI Revision 00 31

Speed vs Power
% Speed 100 90 80 70 60 50
July 10, 2011

% Power 100 73 51 34 22 13
PMI Revision 00 32

Flow control Damper - Most Popular Variable Speed Drive


Recirculation Damper VFC

100

Power

75 50 25 25 50 75 100

VFD Ideal

Flow

July 10, 2011

PMI Revision 00

33

Impact of speed reduction

July 10, 2011

PMI Revision 00

34

Use of VSD: Boiler ID fan case study

July 10, 2011

PMI Revision 00

35

Use of VSD: Boiler ID fan case study (contd.)

July 10, 2011

PMI Revision 00

36

July 10, 2011

PMI Revision 00

37

July 10, 2011

PMI Revision 00

38

July 10, 2011

PMI Revision 00

39

THANK YOU

July 10, 2011

PMI Revision 00

40