Air & Draft System: July 10, 2011 PMI Revision 00 1
Air & Draft System: July 10, 2011 PMI Revision 00 1
Presentation Plan
Various auxiliary equipments in a boiler Need for Draft System Primary and secondary air system in Boiler and their fans Other fans in a boiler Basic of fans: Fan Types and selection Fan laws and factors affecting fan performance Performance curves
PMI Revision 00
PMI Revision 00
Combustion Air
Boiler
Flue Gases
Air needed for combustion Flue are needed to be evacuated Losses due to flow need to be overcome
July 10, 2011 PMI Revision 00 4
PMI Revision 00
Components of PA Fan
Suction Bend With volume Measurement instruments Fan housing with Guide Vanes Main Bearings (Anti Friction) Rotor with impeller with adjustable blade with pitch control Guide vane housing with guide vanes Diffuser with pressure measurement instruments
July 10, 2011 PMI Revision 00 7
PMI Revision 00
PMI Revision 00
PMI Revision 00
10
PMI Revision 00
11
ID Fan
The rotor consists of shaft and assembled impeller and runs in two sleeve bearings that are arranged outside of the housing. The impeller consists of a centre disc and two cover discs that are reinforced by forged rings. The bent blades are welded into position between the impeller discs. The blades are protected by screwed - on wear plates. The shaft is of hollow design. The fan shaft has been rated so that max. operating speed is below the critical speed. Impeller and shaft are connected by means of a flange. This screwing is protected by wear plates. The fan housing is sealed by means of two-part labyrinth seals. Bearings are lubricated with oil.
PMI Revision 00
13
PMI Revision 00
14
PAPH-A
PRIMARY
ECO BYPASS
SCAPH-A
PA FAN -A
TO ESP
SAPH-A
AA205
AA203
SCAPH-A SECOND
AEROFOIL
AA202
AA201
HORIZONTAL S.H
ECONOMISER -1
ECONOMISER -2
ECONOMISER-3
SA HDR
AA204
FD FAN -B
PLATEN S.H
HOT
COMBUSTION CHAMBER
RE HEATER
HOT PA HDR
AA204
AA201
SAPH-B
AA205
AA203
SCAPH-B SECOND
AA202 FD FAN-A
AEROFOIL
COLD SEC. AIR COLD PRIM AIR HOT PRIMARY AIR HOT SEC. AIR FLUE GAS PNEUMATICALLY O/P KNIFE EDGE GATE MOTOR O/P LOUVER DAMPER PNEUMATICALLY O/P LOUVER DAMPER
ECO BYPASS
TO ESP
TO MILLS PA FAN -A
PMI Revision 00
PAPH-B
SCAPH-B
PRIMARY
15
PMI Revision 00
16
ID Fan at Location
PMI Revision 00
17
1FD Fan Inlet 2FD Fan Outlet 3Airheater Inlet 4Airheater Outlet 5Windbox Pressure 6Furnace 7Superheater Platen Inlet
8Reheater Inlet 9LTSH Inlet 10Economiser Inlet 11Airheater Inlet 12E.P. Inlet 13I.D. Fan Inlet
PMI Revision 00
18
Basics on Fans
19
PMI Revision 00
PMI Revision 00
21
Fan types
Centrifugal fan
July 10, 2011 PMI Revision 00
Axial fan
22
Backward Curved
PMI Revision 00
23
PMI Revision 00
24
Axial -flow Fans Type Prope ller Characteristics Low pressure, high flow, low efficiency, peak efficiency close to point of free air delivery Medium pressure, high flow, higher effici ency than propeller type, dip in pressure -flow curve before peak pressure point. High pressure, medium flow, dip in pressure -flow curve, use of guide vanes improves efficiency Typical Applications Aircircul ation, ventilation, exhaust HVAC, drying ovens, exhaust systems Type Radial
Centrifugal Fans Characteristics High pressure, medium flow, efficiency close to tube-axial fans, power increases continuously Medium pressure, high flow, dip in pressure curve, efficiency higher than radial fans, power rises continuously High pressure, high flow, high efficiency, power reduces as flow increases beyond point of highest efficiency Same as backward curved type, highest efficiency Typical Applications Various industrial applications, suitable for dust laden, moist air/gases Low p ressure HVAC, packaged units, suitable for clean and dust laden air / gases
Tubeaxial
Vane axial
Airfoil type
July 10, 2011 PMI Revision 00
PMI Revision 00
27
PMI Revision 00
28
System curve
PMI Revision 00
29
Fan Laws
Flow ? Speed Pressure ? (Speed)2 Power ? (Speed)3
Q1 N 1 = Q2 N 2
SP1 N 1 = SP 2 N 2
kW 1 N 1 = kW 2 N 2
Varying the RPM by 10% decreases or increases the power requirement by 27%.
30
Varying the RPM by 10% Varying the RPM by 10% decreases or increases air decreases or increases the delivery by 10%. static pressure by 19%.
Speed vs Power
% Speed 100 90 80 70 60 50
July 10, 2011
% Power 100 73 51 34 22 13
PMI Revision 00 32
100
Power
75 50 25 25 50 75 100
VFD Ideal
Flow
PMI Revision 00
33
PMI Revision 00
34
PMI Revision 00
35
PMI Revision 00
36
PMI Revision 00
37
PMI Revision 00
38
PMI Revision 00
39
THANK YOU
PMI Revision 00
40