Security Level:
Cell reselection and handover introduction
www.huawei.com
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Content
1. Same priority cell reselection
Basic concepts
Measurement
Trigger
2. Different priority cell reselection
3. Intra frequency handover
4. Inter frequency handover
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 2
Basic concepts for same priority cell
reselection
Ms RSRP value of serving cell
Mn RSRP value of Neighbor cell
Qhyst Hysteresis value for ranking criteria
CellQoffset Cell offset
QoffsetFreq Frequency offset
SNonIntraSearch Threshold for EUTRAN inter-frequency and inter-RAT
SIntraSearch Threshold for intra frequency measurements
Qrxlevmin Minimum required RX level
• Same frequency has same priority and Frequency offset is 0.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 3
Same priority cell reselection – Measurement
• Measurement condition for intra frequency:
Ms <= Qrxlevmin + SIntraSearch
• Measurement condition for EUTRAN inter-frequency and
inter-RAT:
Ms <= Qrxlevmin + SNonIntraSearch
• Remarks:
Qrxlevmin: Minimum required RX level, Default value is -64, unit is
2(dBm)
SIntraSearch: Threshold for intra frequency measurements, Default
value is 29, unit is 2(dB)
SNonIntraSearch: Threshold for EUTRAN inter-frequency and inter-RAT,
Default value is 9, unit is 2(dB)
• Relative Command
MOD CELLRESEL / LST CELLRESEL
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 4
Same priority cell reselection – Measurement
• Sample:
Optimize SNonIntraSearch to 29 for cell 2006-0
MOD CELLRESEL:LOCALCELLID=0,SNONINTRASEARCHCFGIND=CFG,SNONINTRASEARCH=29;
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 5
Same priority cell reselection – Trigger
• Trigger condition for same priority:
Mn – CellQoffset - QoffsetFreq > Ms + Qhyst
• Remarks:
CellQoffset: Cell offset, Default value is 0, unit is 1(dB)
QoffsetFreq: Frequency offset, Default value is 0, Unit is 1(dB)
Qhyst: Hysteresis value for ranking criteria, Default value is 4, unit is
1(dB)
• Relative Command
For CellQoffset of intra frequency:
MOD EUTRANINTRAFREQNCELL / LST EUTRANINTRAFREQNCELL
For CellQoffset of inter frequency:
MOD EUTRANINTERFREQNCELL / LST EUTRANINTERFREQNCELL
For QoffsetFreq of inter frequency:
MOD EUTRANINTERNFREQ / LST EUTRANINTERNFREQ
For Qhyst:
MOD CELLRESEL / LST CELLRESEL
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 6
Same priority cell reselection – Trigger
• Sample:
Optimize CellQoffset to -3dB from cell 2006-0 to cell 2006-7
MOD EUTRANINTERFREQNCELL:LOCALCELLID=0,MCC="311",MNC="570",ENODEBID=2006,
CELLID=7,CELLQOFFSET=dB-3;
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 7
Content
1. Same priority cell reselection
2. Different priority cell reselection
Basic concepts
Cell priority
Measurement
Trigger
3. Intra frequency handover
4. Inter frequency handover
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 8
Basic concepts for different priority cell
reselection
Cellreselpriority Inter frequency cell resel priority
Ms RSRP value of serving cell
Mn RSRP value of Neighbour cell
SNonIntraSearch Threshhold for EUTRAN inter-frequency and inter-RAT
Qrxlevmin Minimum required RX level
ThrshServLow Serving frequency lower priority threshold
ThreshXHigh Inter frequency high priority threshold
ThreshXLow Inter frequency lower priority threshold
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 9
Different priority cell reselection – Cell
priority
• Same frequency has the same priority
• The range of cell priority is from 0 to 7, 7 is the highest
• The default priority of the cell is 7
• Relative Command
MOD CELLRESEL / LST CELLRESEL
MOD EUTRANINTERNFREQ / LST EUTRANINTERNFREQ
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 10
Different priority cell reselection – Cell
priority
• Sample:
Optimize the priority of 700M to 6 according to AWS for site 2006
MOD CELLRESEL:LOCALCELLID=0,CELLRESELPRIORITY=6;
MOD CELLRESEL:LOCALCELLID=2,CELLRESELPRIORITY=6;
MOD EUTRANINTERNFREQ:LOCALCELLID=7,DLEARFCN=5760,CELLRESELPRIORITYCFGIND=CFG,
CELLRESELPRIORITY=6;
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 11
Different priority cell reselection –
Measurement
• Despite the current signal level, serving cell will measure the
neighbor high priority cell:
• Measurement condition for lower priority cell:
Ms <= Qrxlevmin + SNonIntraSearch
• Remarks:
Qrxlevmin: Minimum required RX level, Default value is -64, unit is
2(dBm)
SNonIntraSearch: Threshold for EUTRAN inter-frequency and inter-RAT,
Default value is 9, unit is 2(dB)
• Relative Command
MOD CELLRESEL / LST CELLRESEL
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 12
Different priority cell reselection – Trigger
• Trigger condition for high priority:
Mn > Qrxlevmin + ThreshXHigh
• Trigger condition for lower priority:
Ms < Qrxlevmin + ThrshServLow & Mn > Qrxlevmin + ThreshXLow
• Remarks:
ThreshXHigh: Inter frequency high priority threshold, Default value is 11, unit is
2(dB)
ThreshXLow: Inter frequency lower priority threshold, Default value is 11, unit is
2(dB)
ThrshServLow: Serving frequency lower priority threshold, Default value is 7,
unit is 2(dB)
ThreshXHigh must no larger than ThreshXLow for the same cell
• Relative Command
For ThreshXHigh and ThreshXLow:
MOD EUTRANINTERNFREQ / LST EUTRANINTERNFREQ
For ThrshServLow:
MOD CELLRESEL / LST CELLRESEL
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 13
Different priority cell reselection – Trigger
• Sample for high priority:
Optimize ThreshXHigh to 10 of cell 2006-0
MOD EUTRANINTERNFREQ:LOCALCELLID=0,DLEARFCN=2225,THRESHXHIGH=10,THRESHXLOW=12;
Notice: As ThreshXHigh must no larger than ThreshXLow, so change ThreshXLow concomitantly
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 14
Different priority cell reselection – Trigger
• Sample for lower priority:
Optimize ThrshServLow to 9 of cell 2006-7 / Optimize ThreshXLow to 15 of cell 2006-7
MOD CELLRESEL:LOCALCELLID=7,THRSHSERVLOW=9;
MOD EUTRANINTERNFREQ:LOCALCELLID=7,DLEARFCN=5760,THRESHXLOW=15;
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 15
Content
1. Same priority cell reselection
2. Different priority cell reselection
3. Intra frequency handover
Trigger
4. Inter frequency handover
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 16
Intra frequency handover – Trigger
• Trigger condition(simple formula):
Mn + CELLINDIVIDUALOFFSET – INTRAFREQHOA3HYST > Ms +
INTRAFREQHOA3OFFSET
• Remarks:
Mn: RSRP value of Neighbor cell
CELLINDIVIDUALOFFSET: Cell individual offset, Default value is 0, unit is
1(dB)
INTRAFREQHOA3HYST: Intrafreq handover hysteresis, Default value is 2,
unit is 0.5(dB)
INTRAFREQHOA3OFFSET: Intrafreq handover offset, Default value is 2, unit
is 0.5(dB)
• Relative Command
For CELLINDIVIDUALOFFSET:
MOD EUTRANINTRAFREQNCELL / LST EUTRANINTRAFREQNCELL
For INTRAFREQHOA3HYST and INTRAFREQHOA3OFFSET:
MOD INTRAFREQHOGROUP / LST INTRAFREQHOGROUP
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 17
Intra frequency handover – Trigger
• Sample:
Optimize CELLINDIVIDUALOFFSET to -3 from cell 2009-0 to cell 2008-0
MOD EUTRANINTRAFREQNCELL:LOCALCELLID=0,MCC="311",MNC="570",ENODEBID=2008,CELLID=0,
CELLINDIVIDUALOFFSET=dB-3;
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 18
Content
1. Same priority cell reselection
2. Different priority cell reselection
3. Intra frequency handover
4. Inter frequency handover
Measurement
Trigger
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 19
Inter frequency handover – Measurement
• Measurement start condition:
Ms + INTERFREQHOA1A2HYST < INTERFREQHOA2THDRSRP
• Measurement stop condition:
Ms - INTERFREQHOA1A2HYST > INTERFREQHOA1THDRSRP
• Remarks:
Ms: RSRP value of serving cell
INTERFREQHOA1A2HYST: Interfreq A1A2 hysteresis, Default value
is 2, unit is 0.5(dB)
INTERFREQHOA2THDRSRP: Interfreq A2 RSRP threshold, Default
value is -109, unit is 1(dBm)
INTERFREQHOA1THDRSRP: Interfreq A1 RSRP threshold, Default
value is -105, unit is 1(dBm)
• Relative Command
MOD INTERFREQHOGROUP / LST INTERFREQHOGROUP
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 20
Inter frequency handover – Trigger
• Trigger condition:
Mn + QOFFSETFREQ + CELLINDIVIDUALOFFSET –
INTERFREQHOA4HYST > INTERFREQHOA4THDRSRP
• Remarks:
QOFFSETFREQ: Frequency offset, Default value is 1, unit is 1(dB)
CELLINDIVIDUALOFFSET: Cell individual offset, Default value is 0, unit is
1(dB)
INTERFREQHOA4HYST: Interfreq handover hysteresis, Default value is 2,
unit is 0.5(dB)
INTERFREQHOA4THDRSRP: CoverageBased interfreq RSRP threshold,
Default value is -105, unit is 1(dBm)
• Relative Command
For QOFFSETFREQ:
MOD EUTRANINTERNFREQ / LST EUTRANINTERNFREQ
For CELLINDIVIDUALOFFSET:
MOD EUTRANINTERFREQNCELL / LST EUTRANINTERFREQNCELL
For INTERFREQHOA4HYST and INTERFREQHOA4THDRSRP:
MOD INTERFREQHOGROUP / LST INTERFREQHOGROUP
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 21
Inter frequency handover – Trigger
• Sample:
Optimize CELLINDIVIDUALOFFSET to -3 from cell 2006-7 to cell 2006-0
MOD EUTRANINTERFREQNCELL:LOCALCELLID=7,MCC="311",MNC="570",ENODEBID=2006,CELLID=0,
CELLINDIVIDUALOFFSET=dB-3;
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 22
Thank you
www.huawei.com