Reasons and Solutions
Reasons and Solutions
SDCCH Seizer
CSSR or TCH
Assignment Call completion
Rate (TCH Drop
call)
All cell resources are available but calls are failing, then we
have a call drop scenario. This could be caused by software
errors, congestion, C7 link failures,HW problems or many
other reasons.
clutter.
Mount position
Effective Tilt.
High TR Fail:
Check and clear TR fail from OSS end.
Bad Coverage:
If the drop call is due to low signal strength uplink, check the receive
path of this particular TRX. Check receiver sensitivity, VSWR, feeder
connection and etc. Drops due to Low Signal Strength.
If the drop call reason is due to low signal strength downlink, then,
check the transmit path. Check cards, feeder and etc.
Hardware Fault:
Check Alarms.
TRX condition.
Check Path Imbalance.
VSWR of the Cell.
Connector Connection.
Some times you will find issues on BCCH TRX.In this case BCCH shift
from one to other TRX will reduce SD drop.
Due to ICM Band(CDMA):
Some time SD drops takes place due to near sites of CDMA.
T11 Expired(10 s)
MAIO check.
Use report ZEOL to find the alarms.
Use 208 for Path loss analysis.
Use 196 for UL-DL Interference.
Use 163 report for SD drop.
Use report 216 for detail SD Drop.
232 report for TA report.
62 for Adj cell having same or adj freq.
ND 111 for freq plan.
204 for BTS and cell report.
When TCH is not allocated to the user after SD
allocation ,it is TCH Blocking.
It is the failed call attempts which the MS user can
notice.
It takes place due to lack of TCH Resource.
Some of them are-
High Utilization of TCH
Time slot faulty.
Lock TRXs.
HW Problem.
Implement half rate or Dual rate.
Check FRL & FRU.
Add another TRX.
If TRX addition not possible, try to share the traffic of
If the drop call is due to low signal strength uplink, check the receive
path of this particular TRX. Check receiver sensitivity, VSWR, feeder
connection and etc. Drops due to Low Signal Strength.
If the drop call reason is due to low signal strength downlink, then,
check the transmit path. Check cards, feeder and etc.
If drops are on all sites connected to a single link, then check the slip or
interference on that Abis interface.
If Drops are distributed on all site of the BSC, then check the slips on A-
ter.
TRX condition.