Alarm Check and Trouble Shooting Quick Guide For Claro IuB Interface
Alarm Check and Trouble Shooting Quick Guide For Claro IuB Interface
www.huawei.com
by Carlos Cesar
• 1. IuB Topology
• 1. Basic Script Configuration
• 2. Monitoring RAN Current Fault Alarms
• 3. Main Fault Alarms and Troubleshooting – RNC
• 4. Main Fault Alarms and Troubleshooting – NodeB
IuB Topology
NodeB over ATM:
ATM Network
SAAL Link RADIO RADIO
RNC MUX
MW E1
OF AAL2 Path
NodeB
• 1. IuB Topology
• 1. Basic Script Configuration
• 2. Monitoring RAN Current Fault Alarms
• 3. Main Fault Alarms and Troubleshooting – RNC
• 4. Main Fault Alarms and Troubleshooting – NodeB
NodeB Basic Script Configuration in RNC
NodeB over ATM:
Links for Signaling – Control Plane: Links for Traffic – User Plane:
3 SAAL LINK (ATM Link) 4 AAL2 Path (ID=1, 2, 3 and 4) (ATM Link)
NCP (associate in SAAL LINK)
CCP (associate in SAAL LINK) Link for OM Channel:
ADJNODE (ALCAP) (associate in SAAL LINK) NODEBIP and IPOAPVC (OM IP over ATM)
• 1. IuB Topology
• 1. Basic Script Configuration
• 2. Monitoring RAN Current Fault Alarms
• 3. Main Fault Alarms and Troubleshooting – RNC
• 4. Main Fault Alarms and Troubleshooting – NodeB
Monitoring RAN Current Fault Alarms (by M2000)
Prerequisite
Connection between the M2000 client and the M2000 server is operational.
You have the permission to query alarms.
Procedure
Step 1 Choose Monitor > Current Fault Alarms on the M2000 client. The Filter dialog box is displayed.
Step 2 Select the conditions in the Filter dialog box.
NOTE
When select an alarm you can find some information:
In Alarm Detail Information tab you can find the details of an alarm
In Process Advice tab you can click the link to check the process advice of an alarm.
Procedure
In the Local Maintenance Terminal window, choose Fault Management > Browse Alarm to display
the Alarm Browse window. The upside of the window is the fault alarm browse pane and the downside
is the event alarm browse pane.
Browse alarms in the Alarm Browse windows.
• 1. IuB Topology
• 1. Basic Script Configuration
• 2. Monitoring RAN Current Fault Alarms
• 3. Main Fault Alarms and Troubleshooting – RNC
• 4. Main Fault Alarms and Troubleshooting – NodeB
Main Fault Alarms by RNC
Signaling Link Alarms:
Alarm: SAAL Link Unavailable
Severity Name Alarm Source Location Information Occurrence Time(NT)Alarm ID
Major SAAL Link Unavailable RNCMG06 Subrack No.=3, Slot No.=3, Subsystem No.=0, SAAL link No.=24, Cause=No response timer expiry., NodeB ID=128,
27/6/2010
NodeB01:55
Name=UMGULA21
1802
Major SAAL Link Unavailable RNCMG06 Subrack No.=3, Slot No.=3, Subsystem No.=0, SAAL link No.=26, Cause=No response timer expiry., NodeB ID=128,
27/6/2010
NodeB01:55
Name=UMGULA21
1802
Major SAAL Link Unavailable RNCMG06 Subrack No.=3, Slot No.=3, Subsystem No.=0, SAAL link No.=25, Cause=No response timer expiry., NodeB ID=128,
27/6/2010
NodeB01:55
Name=UMGULA21
1802
1. Possible Causes
(1) Iu/Iur interface link error rate is too high. See the An IMA group => Continue to procedure 2.
handling procedure 1 and 6.
A UNI link => Continue to procedure 3.
(2) Iu/Iur interface link has no credit in a long period.
See the handling procedure 1 and 7. An optical port => Continue to procedure 4.
(3) Timer_NO-RESPONSE expires. See the handling A Fractional IMA Link => Continue to procedure 5.
procedure 1 and 8.
(4) Remote processor is faulty. See the handling (2) Check whether there is any alarm related with
procedure 1 and 9. the IMA group.
(5) Link is released by the peer end. See the handling 1) Check whether there is any alarm related with the
procedure 1 and 10.
IMA group with [Bearing IMA group No.] in the
(6) Link is released by the local SAAL upper user
NBAP/MTP3B. See the handling procedure 1 and 11. "Browse Alarm" window.
(7) No PDU is received from the peer end. See the Y => Continue to step 2).
handling procedure 1 and 12. N => Continue to procedure 6.
(8) Timer_CC expires. See the handling procedure 1 2) Clear the alarm according to the corresponding
and 13. solution procedure.
3) Check whether the alarm is cleared.
2. Handling Suggestions Y => The alarm is cleared. No further actions are
(1) Query the bearer information of the SAAL link. required.
Use the following command: LST SAALLNK with the
following parameters in the alarm: [Subrack No.], [Slot N => The alarm is not cleared. Continue to
No.], [Subsystem No.] and [SAAL link No.]. The bearer procedure 6.
information is shown as follows:
(6) Query the [Cause] parameter in the alarm. 2) Check whether the traffic record parameters are
The parameter value is shown as follows: consistent with those of the peer end. Use the
The Iu/Iur interface link error rate is too high. following command: LST ATMTRF with the traffic
Continue to procedure 7. record index queried in step 1).
The Iu/Iur interface link has no credit in a long Y => Continue to step 5).
period. Continue to procedure 8.
N => Continue to step 3).
The no response timer expires. Continue to
procedure 9. 3) Reconfigure the parameters. Use the following
The remote processor is faulty. Continue to command: MOD SAALLNK.
procedure 10. 4) Check whether the alarm is cleared.
The link is released by the peer end. Continue to Y => The alarm is cleared. No further actions are
procedure 11. required.
The link is released by the local SAAL user. N => The alarm is not cleared. Continue to step 5).
Continue to procedure 12. 5) Check whether the physical devices are well
No PDU is received from the peer end. Continue connected.
to procedure 13. Y => Continue to step 8).
Unknown cause. Continue to procedure 14. N => Continue to step 6).
6) Adjust the connection of the physical devices.
(7) Check the traffic record parameters, physical 7) Check whether the alarm is cleared.
devices, and BER of the physical devices.
Y => The alarm is cleared. No further actions are
1) Query the PVC traffic record index. Use the
following command: LST SAALLNK. required.
N => The alarm is not cleared. Continue to step 8).
1. Possible Causes
(1) Failure in the bearing port of the path, the port Otherwise use the command LST PORTCTRLER to
including Ether port, PPP link, MLPPP link, UNI link, query whether the bearing port has been configured
IMA group, Fractional ATM link and NCOPT port. with the control SPU subsystem? If not, use the
(2) Path has no control SPU subsystem. command ADD PORTCTRLER to add the control
(3) Reset AAL2PATH fail, may caused by wrong SPU subsystem. If it is IPPATH, and the peer address
configuration of peer end. and the local address are in different subnet, then
(4) IPPATH ping check fail. check whether correct IP route is configured? If not,
use the command ADD IPRT to configure the IP
2. Handling Suggestions route.
(1) The cause is "Bearing port unavailable" or "All N => Go to (3).
load balance ports unavailable"?
Y => Use the command LST AAL2PATH or LST (3) The cause is "AAL2PATH reset fail"?
IPPATH to query the bearing port of the path, then Y => Contact the maintenance engineers of the
check whether there is port fault alarm occur? If there peer end.
is the alarm, handle it in accordance with the handling N => Go to (4).
suggestion.
N => Go to (2). (4) The cause is "IPPATH ping fail"?
Y => Check the IP address to be checked by LST
(2) The cause is "No control SPU sub-system"?
IPPATH command, and check whether the network
Y => Use the command LST AAL2PATH to query connection is abnormal? If so, fix the network fault.
whether the bearing port is NULL. If it is NULL, modify N => Contact Support Engineer.
it to a specific port.
• 1. IuB Topology
• 1. Basic Script Configuration
• 2. Monitoring RAN Current Fault Alarms
• 3. Main Fault Alarms and Troubleshooting – RNC
• 4. Main Fault Alarms and Troubleshooting – NodeB
Main Fault Alarms by NodeB
Transmission Link Alarms:
Alarm: E1/T1 Alarm Indication Signal (SIA) (ATM)
Severity Name Alarm Source Location Information Occurrence Time(NT)Alarm ID
Major E1/T1 Alarm Indication Signal UBACAR05 Cabinet No.=0, Subrack No.=0, Slot No.=0, Board type=HBBU, Fault code=NULL, E1T1 Port No.=4 9/7/2010 14:32 2501
Major E1/T1 Alarm Indication Signal UBACAJ07 Cabinet No.=0, Subrack No.=0, Slot No.=0, Board type=HBBU, Fault code=NULL, E1T1 Port No.=0 9/7/2010 14:41 2501
Major E1/T1 Alarm Indication Signal UBAAMA06 Cabinet No.=0, Subrack No.=0, Slot No.=0, Board type=HBBU, Fault code=NULL, E1T1 Port No.=3 9/7/2010 19:05 2501
2. Handling Suggestions 3) Execute DSP E1T1WORKMODE to display the work mode, clock mode, line code,
frame structure, loopback mode, transmission mode and matching impedance of the
1 Check the corresponding E1/T1 settings. alarming E1/T1 port.
a.Check whether the E1/T1 settings are correct: Check whether the displayed information is consistent with the DIP switch settings
and the E1/T1 settings of the far end.
Y => The E1/T1 settings are correct. Go to Y => The displayed information is consistent with the DIP switch settings and the
Procedure 2. E1/T1 settings of the far end. The settings are correct.
N => The displayed information is not consistent with the DIP switch settings and the
N => The E1/T1 settings are incorrect. Go to step b. E1/T1 settings of the far end. The settings are not correct.
b.Correct E1/T1 settings. Note:
There are four E1/T1 line coding modes, including E1/HDB3, E1/AMI, T1/B8ZS, and
c.Check whether the alarm is cleared T1/AMI_ZCS.
Y => The alarm is cleared. The alarm handling ends. The default line coding mode in the E1 mode is HDB3. Different from HDB3 in line
coding principles, AMI has intrinsic defects. Interfacing between AMI and HDB3 will
N => The alarm is not cleared. Go to procedure 2. result in repetitive generation and clearance of E1/T1 LFA alarms and E1/T1 LMFA
alarms on AMI side. Therefore, AMI is not recommended.
The default line coding mode in the T1 mode is B8ZS. Different from B8ZS in line
coding principles, AMI_ZCS has intrinsic defects. Interfacing between AMI_ZCS and
B8ZS will result in repetitive generation and clearance of E1/T1 LFA alarms and
E1/T1 LMFA alarms on AMI_ZCS side. Therefore, AMI_ZCS is not recommended.
Replace BBU
e.Run "RMV AAL2NODE" on the LMT to remove the Caution: Replace BBU with discretion because the it will interrupt the
services carried on it.
faulty ALCAP node. Follow the procedure below to replace BBU:
f.Run "ADD AAL2NODE" on the LMT to add a new 1)Execute ULD CFGFILE to upload NodeB data configuration file. Back
up the NodeB data configuration file to local maintenance terminal.
ALCAP node. The value of PVC and the SAAL 2)Turen off the BBU. Disconnect all the cables on the BBU.
link properties are consistent with those at the 3)Replace the faulty BBU.
4)Reconnect all the cables to the new BBU. Turn on the new BBU. Wait
peer end. until the BBU is started.
g.Run "ADD AAL2PATH" on the LMT to reset AAL2 5)Execute LST VER to list the active software version and BOOTROM
version. Check whether the versions are correct.
paths to the new ALCAP. Y => Versions are correct. Go to step 7).
h.Check whether the alarm is cleared: N => Versions are incorrect. Execute DLD SOFTWARE to download the
NodeB software version and BOOTROM version.
Y => The alarm is cleared. The alarm handling ends. 6)Execute ACT SOFTWARE to activate NodeB BOOTROM version, and
then the software version. Wait until BBU is started.
N => The alarm is not cleared. Go to procedure 3. 7)Execute DLD CFGFILE to download standby NodeB data configuration
file.
8)Execute RST NODEB to restart NodeB. Wait until BBU is started.
3 Replace the BBU. 9)Execute LST ALMAF ti list all the active alarms. Check whether there is
a.Replace the BBU. an alarm of "ALM-3500 Board Version Not Match"
Y => There is such an alarm. Go to step 10).
b.Check whether the alarm is cleared: N => There is no such alarm. Go to step 12).
Y => The alarm is cleared. The alarm handling ends. 10)Execute ACT SOFTWARE to activate BOOTROM version of BBU.
N => The alarm is not cleared. Contact Huawei. 11)Execute RST BRD to reset BBU.
Replace Board
Caution : Replace Board with discretion because it will
interrupt the services carried on it.
1) Disconnect the cables from the board, and then
remove the board.
4 Replace the board. 2) Install a new board. Then connect the cables to the
a.Replace the Board. board. Wait until the board is started.
b.Check whether the alarm is cleared. 3) Execute DSP BRDVER to check if the BootRom
Y => The alarm is cleared. The alarm handling ends. version and software version of the board are correct:
N => The alarm is not cleared, Contact Huawei. Y => correct. Go to step 4.
N => incorrect. Execute ACT SOFTWARE to activate the
BootRom and software.
4) The board replacement is complete.
b.Handle the alarms of E1/T1, UNI, Fractional ATM 4 Reset the NodeB board holding the AAL2 PATH.
and fiber. a.Reset the BBU.
c.Check whether the alarm is cleared: b.Check whether the alarm is cleared:
Y => The alarm is cleared. The alarm handling ends. Y => The alarm is cleared. The alarm handling ends.
N => The alarm is not cleared. Go to procedure 3. N => The alarm is not cleared. Go to procedure 5.
3 Check E1/T1 and fiber connection between 5 Reset the RNC board holding the AAL2 PATH.
NodeB and RNC. a.Reset the RNC board holding the AAL2 PATH. The
a.Check whether the E1/T1 or fiber connection board can be WOIE, WBIE or WXIE.
between RNC and NodeB is correct. b.Check whether the alarm is cleared:
Y => The E1/T1 or fiber connection between RNC and Y => The alarm is cleared. The alarm handling ends.
NodeB is correct. Go to procedure 4. N => The alarm is not cleared. Contact Huawei.
N => The E1/T1 or fiber connection between RNC
and NodeB is not correct. Go to step b.
b.Reconnect the E1/T1 cable or optical fiber correctly.
c.Check whether the alarm is cleared.
Y => The alarm is cleared. The alarm handling ends.
N => The alarm is not cleared. Go to procedure 4.