208 Report Analysis: Company Confidential
208 Report Analysis: Company Confidential
Company Confidential
1 © 2005 Nokia V1-Filename.ppt / yyyy-mm-dd / Initials
Case1: Jumper from TRX 4 to combiner Case2: Jumper from Duplexer to TRX 4 (check
loose (check connectors at both ends) connectors at both ends)
In this case, the Path imbalance (DL-UL) varies between +1.6 to -4dB
which doesn’t tell much
50.00 TRX3 Eg.Pathloss comparisons between TRX’s of same sector can help
40.00
TRX4 identify loose cables or hardware faults, taking other TRX’s as
TRX5
TRX6
reference case
30.00
20.00
10.00
Eg. In Sector A:TRX 3 &4 have only 20% of DL SS samples <-
0.00
>70dBm 70-80dBm 80-90 90-100dBm <100dBm 100dBm whereas TRX 5 & 6 have 70% of their DL SS samples <-
Downlink Signal Strength 100dBm.
Sector B
Prob:1 Combiner Faulty
120.00
Company Confidential
3 © 2005 Nokia V1-Filename.ppt / yyyy-mm-dd / Initials
How to identify the worst cells in your network?
• Import DL & UL pathlosses for all TRX’s of
all cells into separate columns
• Use a pivot table to get Min and Max values of
dL and Ul pathlosses in a cell
• Identify all cells with DL TRX pathloss
variatons >10dB(for a NW with huge TI
quality issues , sstart with 15dB)
• The same can be done for UL also
• A combined analyses for DL& UL with
>10dB diff gave a list of 58 cells for UP(West)
attached below.
• Go back to 208 report for detailed analysis 208_HW issues
Company Confidential
4 © 2005 Nokia V1-Filename.ppt / yyyy-mm-dd / Initials