Sepam 1000+

The document discusses the Sepam 1000+ electrical protection and automation system. It has series 20 and series 40 devices that provide various protection functions for substations, transformers, motors and busbars. Series 20 devices do not have memory capability when power is turned off while series 40 devices can store events for 24 hours. The document describes the various protection types and their settings, characteristics, and display messages.

Uploaded by

Dio Ilham
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
173 views33 pages

Sepam 1000+

The document discusses the Sepam 1000+ electrical protection and automation system. It has series 20 and series 40 devices that provide various protection functions for substations, transformers, motors and busbars. Series 20 devices do not have memory capability when power is turned off while series 40 devices can store events for 24 hours. The document describes the various protection types and their settings, characteristics, and display messages.

Uploaded by

Dio Ilham
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 33

SEPAM 1000 +

Sepam 1000+
~ Systim Electrical protection
Automatision Monitoring
1000 plus
~ 1000 : jenis sepam 1000
~ Plus : bisa komunikasi ( integrasi )
~ Auto : bisa dikendalikan dari sistim
SCADA ( jarak jauh/DCS )
MACAM – MACAM SEPAM 1000 +
Series 20
~ S 20 (subtation)
~ T 20 ( trafo )
~ M 20 ( motor )
~ B 21 ( busbar)
~ B 22 ( busbar )

Series 40
~ S 40 / S 41 / S 42 type
~ T 40 / T 42 type
~ M 41 type
SEPAM 1000+

Series 20
~ Tidak ada capasitor sehingga tidak bisa memori alarm/
kejadian apabila suply tegangan dimatikan tetapi setting
reley masih tetap

~ Memori alarm sampai 16 kejadian ( disply )

~ Memori alarm sampai 64 kejadian (soft wire/SFT)


SEPAM 1000+

Series 40
~ Ada capasitor sehingga bisa memori alarm/kejadian bila
suply tegangan dimatikan dan kemampuannya 24 jam

~ Memori alam sampai 16 kejadian (disply)

~ Memori alarm sampai 128 kejadian ( sft)

~ Accurasi pengukuran kira-kira 1 persen


APPLICATION SERIES 20

Type S 20
~ Substation incomer dan feeder
~ Fungsi protections
+ 50/51 , phase overcurrent
+ 50N/51N , earth fault
+ 46 , negative sequence/unbalance
~ Logig discriminan ( modul MES 108/MES 114 )
~ 4 recloser ( blocking rele atasnya )
APPLICATION SERIES 20

Type T 20

~ Pritection functions
+ 50/51 , phase overcurrent
+ 50N/51N , earth fault
+ 46 , unbalance
+ 49RMS , thermal overload
+ 38/49T ,temperatur monitoring ( MET 148 )

~ dapat mendeteksi trafo ( bucholz/thermostat) dengan


menggunakan
modul (MES 108/MES 114)
APPLICATION SERIES 20

Type M 20
~ protection functions
+50/51, 50N/51N, 46
+49RMS, 38/49T
+37, phase undercurrent
+48/51LR,Starting time dan locked rotor
+66, starts per hour
APPLICATION SERIES 20

Type B 21/B 22
~ Fungsi proteksi tegangan
+27/59, phase to phase under/over voltage
+81L/81H, under/over frequens
+59N, pergeseran tegangan pada titik netral
+27D/47, positive sequence under voltage
+27S, phase to phase under voltage
~ Type B21 tanpa 81R
~ Type B22 ada 81R/ROCOF (pendeteksi kecepatan freq)
APPLICATION SERIES 40

Type S40/41/42
~ Fungsi proteksi
+ 50/51,50N/51N,46,50BF
+ 67N/67NC, relay arah gangguan terhadap tanah
+ 67, relay arah gangguan phase to phase
+ 32P, revers power (daya kembali)

~ Mengukur tegangan,arus,daya dan energi


APPLICATION SERIES 40

Type T40/42
~ Fungsi proteksi
+ 50/51,50N/51N,46,50BF
+ 67N/67NC, relay arah gangguan terhadap tanah
+ 67, relay arah gangguan phase to phase
+ 32P, revers power (daya kembali)
+ 49RMS, 38/49T (temperatur)
~ Mengukur tegangan,arus,daya dan energi
APPLICATION SERIES 40

Type M41
~ Fungsi proteksi
+ 50/51,50N/51N,46,50BF
+ 67N/67NC, relay arah gangguan terhadap tanah
+ 67, relay arah gangguan phase to phase
+ 32P, revers power (daya kembali)
+ semua proteksi yang ada di Type M20

~ Mengukur tegangan,arus,daya dan energi


SEPAM 1000+

UMI (USER MACHINE INTERFACES)

1. Basic Umi
~ metering local dan cara mengoperasikan harus
menggunakan SFT 2841

2. Advances Umi
~ metering lokal,dapat mengoperasikan dari lokal
dan bisa menggunakan SFT 2841

3. Remote Advance Umi


~ menambah fesilitas instal,tidak bisa instal dari
Sepam
SEPAM 1000+

SFT 2841
~ peralatan yang digunakan untuk menset parameter,
fungsi proteksi.Dilengkapi dengan hystori alarm, ge-
lombang recording dan memberikan data parameter
dan penerima data.

Logig Input/Output
~ standart output 4 logig output
~ MES 108 ( 4 logig input,4 logig output )
~ MES 114 ( 10 logig input,4 logig output )
SEPAM 1000+
Sepam 1000+
~ mudah cara menginstal
~ bermacam-macam perlengkapan sepam
~ dapat digabung dengan jarak kurang lebih 100 mm
Suply tegangan
~ 48v-250v dc,110v-240v ac,24v dc
~ logig input : 24v-250v dc
~ terminal yang membedakan dan tahan radiasi
~ input/output modul tidak gandeng
~ temperatur -25 c- 70 c bisa bekerja
SEPAM 1000+

BASE UNIT

~ base unit baru


~ tiga terminal tegangan dari trafo tegangan
~ tiga terminal arus dari trafo arus
~ sama ukurannya antara series 20 dan series 40
~ konsumsi daya kurang dari 15 watt
CHARACTRISTICS SEPAM 1000+

• DIGUNAKAN SESUI DENGAN FUNGSINYA


TRIPPING THRESHOLD
TIME DELAYED
MEMORI TIME

FUNGSI SPECIAL PROTEKSI


PICK UP / DROP OUT
INSTATANIUS TRIPPING
MEMORI KALAU ADA GANGGUAN
RECOVERY TIME ( RESET )
CHARACTRISTICS SEPAM 1000+

2 CHARACTRISTICS TIME DELAYED TRIPPING

~ DT. DEFINIT TIME ( CONSTANTANIUS )


~ IDMT. INVERS DEFINIT MINIMUM TIME

STANDART

~ IEC
~ ANSI
~ IAC
CHARACTRISTICS SEPAM 1000+

CHARACTRISTIC TIME DELAYED

~ IEC IDMT CURVE


K T
PERSAMAANNYA : Td =
X ß
@
( I/Is ) - 1

CURVE K @ ß

SIT 0,14 0,02 2,97


VIT 13,5 1 1,5
LIT 120 1 13,3
EIT 80 2 0,8
UIT 315,2 2,5 1,0
CHARACTRISTICS SEPAM 1000+

• IEEE IDMT curve:

PERSAMAANNYA : Td = A + B X T

@
( I/Is ) – 1 ß
CURVE A B @ ß

Mod Inv. 0,0103 0,0228 0,02 0,2414


Verry Inv. 3,922 0,0982 2 0,1378
Extre.Inv. 5,64 0,0243 2 0,0813
CHARACTRISTICS SEPAM 1000+

• IAC IDMT curve

persamaannya : Td = A+ B + D + E T
2 3 ß
(I/Is – C) (I/Is –C) (I/Is – C)

CURVE A B C D E

IAC Inv. 0,2078 0,8630 0,8000 -0,4180 0,1947


Verry Inv. 0,0900 0,7955 0,1000 -1,2885 7,9586
Extrem Inv. 0,0040 0,6379 0,6200 -1,7872 0,2461
CHARACTRISTICS SEPAM 1000+

• CURVE DEFINIT TIME


t

Operation zone

I/Is
Is I

Is : 0perating current threshold


T : pritection operating delay (constan)
CHARACTRISTICS SEPAM 1000 +

• INVERS DEFINIT MINIMUM TIME CURVE

t
Operation zone

I/Is
I 1,2 10 20 I

Is : OPERATING CURRENT THRESHOLD


T : PROTECTION OPERATION DELAY , I = 10XIs
CHARACTRISTICS SEPAM 1000+
• TMS : Time Multiplier Setting TMS = 1 , T = 2,97s

TMS = 0,337 , T = 1 s
t
IEC SIT curve TMS = T/2,97

IEC VITcurve TMS = T/1,5


2,97
IEC EIT curve TMS = T/0,808
1
IEC LIT curve TMS = T/13,33
I/Is
10

Example for IEC SIT


SEPAM 1000 +

• PROTECTION 50/51(overcurrent)
I set point
~ Definit Time 0,1In – 24In
~ IDMT 0,1In – 2,4In

Time delay
~ Definit Time Inst. 50 ms – 300 ms
~ IDMT 100 ms – 12,5 s/TMS
Accuracy ± 5%
Bila terjadi trip Display muncul “ PHASE FAULT “
SEPAM 1000 +

• PROTECTION 50N/51N (Earth O C)


I set point
Definit Time – SUM 3I 0,1In – 15In
- sensor CSH
2A rating 0,2 A - 30 A
5A rating 0,5 A - 75 A
20A rating 2 A - 300 A
SEPAM 1000 +
• PROTECTION 50N/51N (Earth O C)
• IDMT Time
SUM 3I - 0,1In – In
Sensor CSH
2A rating 0,2A - 2A
5A rating 0,5A - 7,5A
20A rating 2A - 20A
T set Definit Time Inst. 50ms - 300s
IDMT Time 100ms - 12,5s

# Bila Trip Display akan muncul “ EARTH FAULT”


SEPAM 1000 +

• PROTETECTION 46 (Unbalance)
• I set point
Definit Time 10% Ib - 500% Ib
IDMT Time 10% Ib - 50% Ib
Schneider IDMT 10% Ib - 50% Ib
Time Delay
Definit 100ms - 300ms
IDMT 100ms - 1s

# Bila Trip Display muncul “ UNBALANCE “


SEPAM 1000 +

• PROTECTION 49RMS (Thermal O Load)


• Set Point
Es1 Alarm set point 50% - 300%
Es2 Tripping set point 50% - 300%
Time Delay
T1 (Heat rise) 1mn - 600mn
T2 (Cooling) 5mn - 600mn
Accuracy ± 2%
# Bila Heating mencapai Es1,display muncul “ALARM
THERMAL” dan bila mencapai Es2 akan muncul “THERMAL
OVERLOAD” dan diikuti dg alarm “START INHIBIT”
SEPAM 1000 +

• PROTECTION 37 (UNDERCURRENT)
I set pont 15% - 100%
Accuracy ± 5%

Time Delay 50ms - 300ms


Accuracy ± 2%

# Bila terjadi Trip display akan muncul “UNDER


CURRENT”
SEPAM 1000 +

• PROTECTION 48-51LR (Excessive start time,Locked


Rotor)
I set point 50%Ib - 500%Ib
Accuracy ± 5%

Time delay ST 500ms - 300s ( LONG START)


LT 50ms - 300s ( BLOCK ROTOR)
LTS 50ms - 300s
Accuracy ± 2% ( 25ms)
SEPAM 1000 +

PROTECTION 66 (Start perhour)


~ Start yg sering akan menimbulkan panas yg berlebihan
dan menyebabkan kerusakan pada Winding Motor
Setting point : Pereode 1 - 6 Hour
Nb of start 1 - 60X
Nb of hot start 1 - Nb of start
Nb of cool start 1 - Nb of start
Time Delay stop/start 0mn - 90mn
# Bila Trip,display akan muncul “ START INHIBIT”
SEPAM 1000 +

PROTECTION 27/27S (Undervoltage)


Set point Us/Vs 5%Uns/Vns - 100%Uns/Vns
Accuracy ± 2%

Time Delay 50ms - 300s


Accuracy ± 2% (25ms)

# Bila Trip, display akan muncul “UNDERVOLTAGE”


SEPAM 1000 +

• PROTECTION 59 (Overvoltage)
• Us/Vs set point 50%Uns/Vns-150%Uns/Vns
Accuracy ± 2%

Time Delay 50ms - 300s


Accuracy ± 2%

# Bila Trip,display muncul “OVERVOLTAGE”