GUIDEBOOK For FTTH Premise OSP v1 (1) .0
GUIDEBOOK For FTTH Premise OSP v1 (1) .0
WORK IMPLEMENTATION>
Copyright©Fujikura Ltd./K.A Page 1 Guide book for FTTH-Premise v 1.0 May 2014)
8/12/24c SSW
8/12/24c SCPT
8/12/24c SCPT
Copyright©Fujikura Ltd./K.A Page 2 Guide book for FTTH-Premise v 1.0 May 2014)
Materials for FTTH OSP (STO - ODP)
Distribution Cable
ODP (Wall Mount)
(Aerial)
Note (*1): See Note (*1)
ODP-CA-8/16
For Aerial locations under SP#2 AC-OF-SM-8/12/24-SC
and after, intermediate ODPs ODP (Aerial)
may not be installed unless there
is an immediate demand. ODP-SSW-8
Branching ODP 1) ODP-SSW-8: To be installed (1:8 Splitter built-in)
(Pole/Wall Mount) at every end point including
the branching section.
ODP-PW-BR 2) ODP-PW-BR: To be installed
at the branching point and the
end point where future Line Guard/
extension is expected.
Suspension
Branching ODP Ring Clamp
(Pedestal)
C-Clamp
ODP-PL-BR
ODP (Pedestal)
PS-1-2-ODC/ PS-1-8-ODP
PS-1-4-ODC
Distribution Cable
(Duct)
STO
Jointing Closure Type/Designator
DC-OF-SM-8/12/24-SC
for 12c-24c SC-OF-SM-24
Copyright©Fujikura Ltd./K.A Page 3 Guide book for FTTH-Premise v 1.0 May 2014)
Materials for FTTH-OSP (HRB: High-Rise Building)
ODP-HRB Indoor Cable
(2-C Low Friction)
ODP-HRB-16/32 PS-1-8-ODP-HRB
IC-OF-SM-2D
Indoor Cable
(1-C Low Friction)
IC-OF-SM-1D
FUSE-CONNECT
ISC-UPC-FD
PS-1-4-ODC-HRB ROSETTE
RS-IN-SC-1P/
ODC-HRB TC-MK-SC-1P
Copyright©Fujikura Ltd./K.A Page 4 Guide book for FTTH-Premise v 1.0 May 2014)
(Reference for Installation Work)
Copyright©Fujikura Ltd./K.A Page 5 Guide book for FTTH-Premise v 1.0 May 2014)
(Reference for Installation Work)
Copyright©Fujikura Ltd./K.A Page 6 Guide book for FTTH-Premise v 1.0 May 2014)
Instalasi Kabel Udara (SSW)
Penarikan Kabel Udara (SSW) SAG (Andongan kabel: d) PENARIKAN KABEL SSW:
= 1 - 2% x L
Kabel SSW bisa ditarik cukup
d dengan tenaga TANGAN tanpa
Do not pull cable while cable alat seperti TRACK TANG/
is laied on the ground!! KATREK.
Suspension
PERHATIAN: Wire
At the cable laying, turns/twist (Melintir)
in the cable shall be released by turning
the cable winding while making the 8-
figure or to be pulled without making 8- Cable Part
figure.
Copyright©Fujikura Ltd./K.A Page 7 Guide book for FTTH-Premise v 1.0 May 2014)
Pemasangan C-CLAMP
C-CLAMP shall be installed at:
1. Riser Point
2. Curve Point with the inner angle LESS THAN 120°
3. End Point of the cable with ODP-SSW-8 or ODP-PW-BR
150mm remove sheath
3. End Point
1. Riser Point 2. Curve Point 1) ODP-SSW-8
C-CLAMP x 2 10cm 50mm
C-CLAMP x 2
SSW CABLE
± 1.0m
Cable part shall
be protected with
Spiral for outdoor 2) ODP-PW-BR
use (Black color)
Copyright©Fujikura Ltd./K.A Page 8 Guide book for FTTH-Premise v 1.0 May 2014)
Pemasangan LINE-GUARD
(2)
(1)
(1)
(1) (1) (2) (1) (1) (2) ........... C-CLAMP x 2
Copyright©Fujikura Ltd./K.A Page 9 Guide book for FTTH-Premise v 1.0 May 2014)
Pemasangan ODP-SSW-8 (Instalasi JIka Ada Permintaan Pemasangan)
±30cm
±25cm
ODP-SSW-8
±30cm L= 51cm
SUSPENSION CLAMP
±30cm
10cm PERHATIAN:
In case if LINE GUARD is not installed at the location
where ODP-SSW-8 will be installed, the LINE GUARD shall
be installed at the time of ODP-SSW-8 installation.
Copyright©Fujikura Ltd./K.A Page 10 Guide book for FTTH-Premise v 1.0 May 2014)
(Reference for Installation Work)
Copyright©Fujikura Ltd./K.A Page 11 Guide book for FTTH-Premise v 1.0 May 2014)
Slack for Branching ODP-SSW
Branching Cable
(SSW-8-core)
Main Cable
(SSW-12/24-core)
± 1.0m
33/40
± 1.5m ± 1.0m
± 1.5m
2m
1.5m
Copyright©Fujikura Ltd./K.A Page 12 Guide book for FTTH-Premise v 1.0 May 2014)
(Reference for Installation Work)
Copyright©Fujikura Ltd./K.A Page 13 Guide book for FTTH-Premise v 1.0 May 2014)
ODP Pedestal
L=±6.0m (*1)
1m
ODP
1m
1m
ODP
HH-PIT-60
Note (*1): Remaining Cable Slack after
Cable Slack Length during ODP Installation Work: ODP Installation Work shall be pulled
L= 2 x (1.5m+1m)+1.0m=6.0m back and kept in HH-PIT-60.
Copyright©Fujikura Ltd./K.A Page 14 Guide book for FTTH-Premise v 1.0 May 2014)
Slack for Branching ODP Pedestal
± 1m
± 1.5m
± 1.5m
1m
Copyright©Fujikura Ltd./K.A Page 15 Guide book for FTTH-Premise v 1.0 May 2014)
(Reference for Installation Work)
Copyright©Fujikura Ltd./K.A Page 16 Guide book for FTTH-Premise v 1.0 May 2014)
Wall Mount ODP
(In case when ODP Installation will be done on the ground)
ODP-CA
1m
1m
Copyright©Fujikura Ltd./K.A Page 17 Guide book for FTTH-Premise v 1.0 May 2014)
INSTALLATION OF ODP WALL (1)
Approx.
5cm
Gap between steel pipe (Ф
2") and ODP (Wall Mount) In case Gap between
Gap between steel pipe (Ф shall be less than 10cm steel pipe (Ф 2") and ODP
2") and ODP (Wall Mount) (Wall Mount) is more than
shall be less than 10cm 5cm, cables shall be
A (See Identification Marking protected with spiral or
detail.) (White color) shall be flexible pipe (Black color)
applied on the cable of
"Up-stream/ODC" side.
Approx.
Approx.
10cm
10cm
HDPE Pipe 33/40
@ < 1.0m
wall.
installed until the level with
Galvanized Steel Pipe..
10cm
G.L.
30cm
Approx.
20cm
10cm
Approx.
10cm
B (See detail.)
10cm
G.L.
10c 30cm
30cm 30cm 30cm
m
Details "B"
Copyright©Fujikura Ltd./K.A Page 18 Guide book for FTTH-Premise v 1.0 May 2014)
INSTALLATION OF ODP WALL (2)
(In case pipe shall be buried in the wall)
Flex. Pipe
Drop Cable
Note:
In case when pipes shall be buried in the building wall due to the
Appro requirement by the developer, the following points shall be taken into
x. 100 account for the installation.
R≧300 PVC/High-Impact
150 conduit.
Conduit OD Ф25mm
5. PVC Simple Socket for OD 25mm Pipe shall be used at all jointing part.
50 6. Pipe space of wall shall be filled with concrete after installation of ODP.
(ODP termination work shall be done prior to the pipe fixing and concrete
100 2 x PVC Ф50 work.)
(L=200)
7. The wall shall be restored to the original condition and painted with the
same color with the original wall.
MOM/BA shall be made (to be signed by the PIC of the developer) for the
confirmation of the requirement.
Copyright©Fujikura Ltd./K.A Page 19 Guide book for FTTH-Premise v 1.0 May 2014)
(Reference for Installation Work)
Copyright©Fujikura Ltd./K.A Page 20 Guide book for FTTH-Premise v 1.0 May 2014)
(Reference for Installation Work)
Copyright©Fujikura Ltd./K.A Page 21 Guide book for FTTH-Premise v 1.0 May 2014)
Pemasangan Drop-Core KU (Instalasi JIka Ada Permintaan Pemasangan)
LEGEND
: S-Clamp (Japan)
: D-Clamp (Japan)
: BW-Clamp (Local)
Copyright©Fujikura Ltd./K.A Page 22 Guide book for FTTH-Premise v 1.0 May 2014)
Cable
S clamp
Aerial Drop
cable
Cable core
Copyright©Fujikura Ltd./K.A Page 23 Guide book for FTTH-Premise v 1.0 May 2014)
Drop Cable installation Drop Cable installation
with BW clamp without BW clamp
Cables to
Customer's house
Cable element
Cables from closure
BW clamp
Supporting wire
Supporting wire
Cables from closure
S clamp
Copyright©Fujikura Ltd./K.A Page 24 Guide book for FTTH-Premise v 1.0 May 2014)
Fixing of Drop cable
Supporting wire
(Steel)
Neck optical fibers
Cable Body
portion (fibers)
Step 1 ) Cut the neck of the cable with a cutter Step 2 ) Separate the supporting wire from the cable body
Approx. 25cm
Copyright©Fujikura Ltd./K.A Page 25 Guide book for FTTH-Premise v 1.0 May 2014)
Fixing of Drop cable
supporting wire
supporting wire supporting wire
Important!!
End of supporting wire must be
taught with the metallic part
COMPLETED PIECE
supporting wire
Copyright©Fujikura Ltd./K.A Page 26 Guide book for FTTH-Premise v 1.0 May 2014)
(Reference for Installation Work)
Copyright©Fujikura Ltd./K.A Page 27 Guide book for FTTH-Premise v 1.0 May 2014)
Drop cable installation into ODP Pedestal
Use duct from ODP to customer premise
HH-PIT-40
HH-PIT-40 - Premises
1) BC-TR-0.4 + PP-OF-OUT(PVC ¾”)
HH-PIT-40
Copyright©Fujikura Ltd./K.A Page 28 Guide book for FTTH-Premise v 1.0 May 2014)
(Reference for Installation Work)
Copyright©Fujikura Ltd./K.A Page 29 Guide book for FTTH-Premise v 1.0 May 2014)
Examples of drop cable/indoor cable installation into house
Use Air Condition ducts Use Telephone ducts Drill new hole
(~10mm dia. )
Indoor cable
Outside
Copyright©Fujikura Ltd./K.A Page 30 Guide book for FTTH-Premise v 1.0 May 2014)
Copyright©Fujikura Ltd./K.A Page 31 Guide book for FTTH-Premise v 1.0 May 2014)
★Standard:
Bend the Cable top to avoid cable being stuck while pushing through conduits
About 10mm
Copyright©Fujikura Ltd./K.A Page 32 Guide book for FTTH-Premise v 1.0 May 2014)
CORRECT PUSHING METHOD
Ensure the stroke length is short (about 50mm)
Correct Method Wrong Method
Photo
Stroke
Short (about 50mm) Avoid Long stroke length
length
Copyright©Fujikura Ltd./K.A Page 34 Guide book for FTTH-Premise v 1.0 May 2014)
Examples of indoor cable installation inside house with trunking
Copyright©Fujikura Ltd./K.A Page 35 Guide book for FTTH-Premise v 1.0 May 2014)
Examples of "ONU Hiding installation" into house
Copyright©Fujikura Ltd./K.A Page 36 Guide book for FTTH-Premise v 1.0 May 2014)
Examples of drop cable installation into house
Copyright©Fujikura Ltd./K.A Page 37 Guide book for FTTH-Premise v 1.0 May 2014)
Examples of drop cable installation into house ( Agata's home )
Copyright©Fujikura Ltd./K.A Page 38 Guide book for FTTH-Premise v 1.0 May 2014)
Examples of drop cable installation into house ( Agata's home )
Copyright©Fujikura Ltd./K.A Page 39 Guide book for FTTH-Premise v 1.0 May 2014)