Building automation systems (BAS) monitor and control a building's mechanical and lighting systems to improve efficiency. BAS keeps temperatures and lighting within specified ranges based on occupancy schedules. This provides energy savings, cost savings, improved working conditions, and environmental benefits. Controllers are used to monitor inputs like temperature and control outputs to regulate devices. Programmable logic controllers provide the most control but cost more. System controllers are commonly used in office buildings. Terminal unit controllers control smaller devices like fans or lights. BAS also controls humidity, air handling, and integrates with security and fire systems. Lighting is automated based on occupancy and daylight.

Uploaded by

Abhishek Rawat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views

BAS

Building automation systems (BAS) monitor and control a building's mechanical and lighting systems to improve efficiency. BAS keeps temperatures and lighting within specified ranges based on occupancy schedules. This provides energy savings, cost savings, improved working conditions, and environmental benefits. Controllers are used to monitor inputs like temperature and control outputs to regulate devices. Programmable logic controllers provide the most control but cost more. System controllers are commonly used in office buildings. Terminal unit controllers control smaller devices like fans or lights. BAS also controls humidity, air handling, and integrates with security and fire systems. Lighting is automated based on occupancy and daylight.

Uploaded by

Abhishek Rawat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 10

BUILDING AUTOMATION SYSTEM

Building automation describes the advanced functionality provided by the control system of
a building It is a computerized, intelligent network of electronic devices designed to monitor
and control the mechanical and lighting systems in a building.

Basic functions of BAS


BAS keeps the building climate within a specified range, provides lighting based on an
occupancy schedule, and monitors system performance and device failures and provides
email and/or text notifications to building engineering/maintenance staff.

Benefits of BAS

Energy efficiency
Cost savings
Improved working conditions
Environmental benefits
Inputs and outputs are either analog or digital.

ANALOG DIGITAL

Analog inputs are used to read a variable A digital input indicates if a device is
measurement. Examples turned on or not.
are temperature, humidity
and pressure sensor

Analog outputs control the speed or Digital outputs are used to open and close
position of a device, such as a variable relays and switches. An example would be
frequency drive. An example is a hot to turn on the parking lot lights when
water valve opening up 25% to a photocell indicate it is dark outside.
maintain a setpoint.
CONTROLLERS

Controllers are essentially small, purpose-built computers with input and output
capabilities. These controllers come in a range of sizes and capabilities to control devices
commonly found in buildings, and to control sub-networks of controllers.

Inputs allow a controller to read temperatures, humidity, pressure, current flow, air flow,
and other essential factors.
The outputs allow the controller to send command and control signals to slave devices,
and to other parts of the system. Inputs and outputs can be either digital or analog.

Controllers used for building automation can be grouped in 3 categories.


Programmable Logic Controllers (PLCs)
System/Network controllers
Terminal Unit controllers
Programmable Logic Controllers (PLCs)

Most responsiveness and processing power.


Costs typically 2 to 3 times that of a System/Network controller .
It may be used to automate high-end applications such as clean rooms or hospitals
where the cost of the controllers is less of a concern.

System network controllers


System/Network controllers may be applied to control one or more mechanical systems
such as an Air Handler Unit (AHU), boiler, chiller, etc., or they may supervise a sub-
network of controllers. These are generally used in office buildings, supermarkets,
malls.etc.

Terminal Unit Controllers

Terminal Unit controllers usually are suited for control of lighting and/or simpler
devices such as a package rooftop unit, heat pump, VAV box, or fan coil, etc.
Occupancy

Occupancy, Unoccupied, Morning Warmup, and Night-time Setback are common modes of
a building automation system.

Occupancy is usually based on time of day schedules. In Occupancy mode, the BAS aims to
provides a comfortable climate and adequate lighting. A temperature sensor in the zone
provides feedback to the controller, so it can deliver heating or cooling as needed.

During Morning Warmup the BAS tries to bring the building to setpoint just in time for
Occupancy. This is also referred to as Optimised Start.

Alarms and Security


Many building automation systems have alarm capabilities. If an alarm is detected, it can be
programmed to notify someone. Notification can be through a computer, pager, cellular
phone, or audible alarm.

Common temperature alarms are: space, supply air, chilled water supply and hot water
supply.
Carbon monoxide and carbon dioxide sensors can be used to alarm if levels are too high.
Refrigerant sensors can be used to indicate a possible refrigerant leak.
Security systems can be interlocked to a building automation system. If occupancy sensors
are present, they can also be used as burglar alarms.

Fire and smoke alarm systems can be hard-wired to override building automation. For
example: if the smoke alarm is activated, all the outside air dampers close to prevent air
coming into the building, and an exhaust system can isolate.

Lighting control

Lighting can be turned on, off, or dimmed with a building automation or lighting control
system based on time of day, or on occupancy sensor, photosensors and timers.
Eg - to turn the lights in a space on for a half hour since the last motion was sensed.
A photocell placed outside a building can sense darkness, and the time of day, and
modulate lights in outer offices and the parking lot.
Humidity control

When relative humidity at the desired temperature set-point is too high, dehumidification
is required to reduce the amount of water vapour in the air for humidity control and vice
versa.

Commonly used dehumidification methods include:


1) Surface dehumidification on cooling coils simultaneous with sensible cooling.
2) Chilled water spray dehumidification with direct contact.
3) Direct dehumidification with desiccant-based dehumidifiers.

In a centralized air- conditioning system , a duct mounted stream humidifier is usually


used. When the relative humidity of the space drops below the humidity controller set
point, a control signal is generated to open the steam valve at the inlet to the duct
mounted humidifier unit. When the steam valve is positioned open , steam flows
through the humidifier in the supply air stream to the space, which raises the relative
humidity of the space eventually.
Air handlers

Most air handlers mix return and outside air so less temperature change is needed. This can
save money by using less chilled or heated water (not all AHUs use chilled/hot water
circuits). Some external air is needed to keep the building's air healthy.

Analog or digital temperature sensors may be placed in the space or room, the return and
supply air ducts, and sometimes the external air.

Actuators are placed on the hot and chilled water valves, the outside air and return air
dampers.

The supply fan (and return if applicable) is started and stopped based on either time of day,
temperatures, building pressures or a combination.