BRC1H Service Training
BRC1H Service Training
Secret
Internal use only
Public
Commercial
controller
BRC1H*
1. Overview
3. Configuration
4. Addressing
5. Functions
A. Duty Rotation
B. External input interlock
C. Force fan ON
6. Software update
7. Troubleshooting
8. Madoka App
01 Overview
Line-up:
Hardware:
• Trendy & contemporary design
• Compact size (85x85 mm)
• Daikin eye in line with the portfolio
• Touch button for the setting except on/off
5 BRC1H Service Training - Internal use only
BRC1H*Touch buttons interface
INFORMATION
The controller is equipped with a power saving function that causes the screen
to go blank after a period of inactivity. To make the screen light up again, press
one of the buttons.
6 BRC1H Service Training - Internal use only
7 BRC1H Service Training - Internal use only
Operation
The controller allows for making field settings related to the indoor
unit, and to the controller itself.
1. Modes ("Mode"),
2. Units ("Unit"),
3. Settings ("SW"),
The field settings menus have two levels. You set modes and
units in the first level, and settings and values in the second.
16 BRC1H Service Training - Internal use only
Remote controller field settings
Remote controller field setting R1-11 allows for the status indicator to be
set to a mode suitable for use in hotels. According to the value that is set
for this setting, the status indicator has the following behaviour:
The indoor unit is released from its masterhood. The controllers of all indoor
units display a blinking "changeover under centralised control“ icon.
Group address
To control the system with central control equipment, you need to
set addresses for:
• Groups ("Group") and/or
• Units ("Group(Unit)").
The Group address and Airnet address menu has two levels. You
define groups and/or units in the first level, and set or release
addresses for those groups and/or units in the second.
To RELEASE an address
that was previously set,
change to and then
apply
settings.
AirNet address
To connect the system to the AirNet monitoring and diagnostics
system, you need to set AirNet addresses for:
• Indoor units ("I/U")
• Outdoor units ("O/U")
The Group address and Airnet address menu has two levels. You
define groups and/or units in the first level, and set or release
addresses for those groups and/or units in the second.
First level Indoor unit Second level Outdoor unit Second level Value
Indoor unit (I/U) Outdoor unit (O/U) Define an address for the
indoor/outdoor unit.
Define the indoor Define the outdoor unit To SET an address, make
unit for which you for which you want to set sure is selected.
want to set an AirNet an AirNet address.
address.
This table shows –as a rule of thumb- the amount of units per group:
No. of indoor units No. of groups No. of Remocon No. of Back-up Units
1–4 1 1 1
5–8 2 2 2
9 – 12 3 3 3
13 - 16 4 4 4
External input interlock allows for the integration of key card and
window contact logic into the system.
• it is not possible to connect a second (slave) controller, and
• the schedule function will be disabled for as long the adapter is
connected to the indoor unit.
Unit stays Off if state was Off before window was opened.
Reset Mode "Default Reset Setting" operation Auto, Cooling, Heating, Fan "--“
mode only,
Reset Cool SP "Default Reset Setting" cooling See indoor unit's setpoint "22°C"
setpoint range and setpoint range
limitation, "--"
Reset Heat SP "Default Reset Setting" heating See indoor unit's setpoint "22°C"
setpoint range and setpoint range
limitation, "--"
When the value for a parameter is "- -", this means that when the timers expires,
36 BRC1H Service Training - Internal use only
nothing changes for that parameter and the current active value is kept.
Key Card logic:
< B2 Delay Timer Unit keeps operating until Delay Timer ends.
> Delay + Reset Timer Unit starts according to the reset conditions.
Result: The fan of the indoor unit that corresponds to the selected
indoor unit number starts operating.
41 BRC1H Service Training - Internal use only
06 Software Update
Remote controller software
update
Updater Prerequisite:
a) PC USB cable EKPCCAB4 or higher (includes a USB cable and additional
connection cables)
b) PC with Updater (download last version from the Daikin Business portal)
When the system is in error and the controller presents you with
an error screen from as soon as you try to enter the main menu,
follow the corresponding troubleshooting procedure of indoor and
or outdoor unit’s service manual.
2
App requires Bluetooth Connection.
If Bluetooth is disabled or App is
encountering Bluetooth issues:
• Enable Bluetooth if it’s disabled
• Disable and enable again to refresh if 3
App addresses that it’s off even it is
on.
1
49 BRC1H Service Training - Internal use only
Pairing
The pairing between the Madoka Assistant and Madoka is based on numeric
comparison:
On Bluetooth menu, the pairing may be shown. Access Bluetooth menu to check
communication. If all is set, Bluetooth icon and smart phone icon with communication arrows
are displayed.
Normal Communication Screen Problem 1: Previous Pairing Data Problem 2: Bluetooth feature
is deleted by BRC1H is disabled by BRC1H
To solve the issue, go to Bluetooth connection screen on your smart phone and make the phone
to forget this connection. Close Madoka app and re-start it. Make sure Bluetooth feature is ON
for remocon. When pairing, this time, remocon will generate access code and display to accept.
In the mean time, click pair on your smart phone.
If Bluetooth feature is not enabled on BRC1H, a Bluetooth icon will not be displayed on home screen.
Bluetooth sub menu on remocon will indicate the feature is OFF.
App will not discover BRC1H.
If Bluetooth feature is disabled during an active Bluetooth connection. App will generate connection error.
Turn on Bluetooth feature through submenu on Remocon.
55 BRC1H Service Training - Internal use only
App – Home Screen
All available connections and previous connections are displayed on home screen.
Maximum limit is 10 for historical units. When connection count is more than 10,
oldest historical connection will be overwritten.
When Menu icon is clicked on top left, below screen will be accessed.
Demo Mode is provided to explore app features without a real BRC1H connection. Demo mode also equips a demo
firmware update simulation, which does not actually update firmware. For real features and connections, you should exit
demo mode.
Whenever a firmware update is available, you will be prompted to apply update. During the procedure BRC1H, cellular
data for app or Wifi, Bluetooth connection between the app and BRC1H should be active.
When multiple BRC Connections are available, to define which connection belongs to which BRC1H, “Test Connection”
feature may be used. When “Test Connection” button is clicked, connected BRC1H Daikin Eye will blink a few times
confirming the Connection is OK and also commanding unit from the app is paired to that BRC1H.
Settings
Notification
When there is a notification, warning or error, Settings
Message Button also indicates it)
OFF ON
Indoor
Temperature
& Mode Selection
Outdoor
Temperature
3
2
1 2
2.1
2. Manual Fan Speed Selection 2. Auto Fan Speed Selection Main Screen
3. Click anywhere else in the screen to return to main screen.
64 BRC1H Service Training - Internal use only
App – Horizontal Airflow Direction
Available Airflow Options depend on the type of indoor unit. They are not APP’s features.
3 3 3
3
1
2 2 2
Fixed : Manual Positioning Swing Auto
3 3
3 3
1
2
2 2
Fixed : Manual Positioning Swing Auto
1 3
2 2
2
Slide downwards or upwards to access different sub-menus. Amount of content displayed at a time depends on
your smart phone’s resolution. (3) Click back button to return back to main screen.
67 BRC1H Service Training - Internal use only
App – Unit Settings – Installer Mode
Available Unit Settings also depend on the user level. To see all items, switch to Installer Mode
1 7
4
2 5 5
3
6
11
8
10
12 13
14
15
All Settings available are listed in You may quit from installer mode manually vie shown procedure, or if 30 minutes is selected, app will kick you out
Installer Mode. of installer mode when 30 minutes expire or you may choose to stay in installer mode indefinitely.
4
1 Check Communication Module’s current version and new version if
an update is available.
Click Update Firmware to update.
App displays only status, it is a read only value, you cannot write
Master/Slave Setting with the app.
Screen settings are for BRC1H screen, not app or smart phone
2 2 settings.
4
(5) Click Back to return to previous menu.
Status Indicator is the Daikin Eye: light ring around the remocon.
Mode: Status Indicator’s Mode Setting. This is a read only value for
Field Setting Mode:R1, SW:11. You cannot change this value with App.
You may change the intensity of status indicator light via app.
2 Intensity setting is under Installer Settings on BRC1H.
2
2
You may set the date and the time for BRC1H remocon via app. You
3 may either choose to synchronize with device to use smart phone’s
date and time to set to BRC1H or set them manually.
1
(2) Click Back to return to previous menu.
Failure to delete both information from the remocon and the phone
will result with bonding problem mentioned on Section: Common
Problems with Connection, Problem 1
1 2 Time Time
Cooling Adjustment Heating Adjustment
3 Interval Interval
Time Time
1
Cooling Adjustment Heating Adjustment
Interval Interval
You may limit maximum Cooling Set Point and/or minimum Heating Set
Point while Presence Sensor is Enabled. In this example cooling set point
may not rise more then 27 ˚C even if the calculated set point is more
than 27 ˚C. Similarly, heating set point may not drop below 20 ˚C even if
2 the calculated set point is below than 20 ˚C.
5 ON
2 OFF
1 3 Time
Room Unoccupied
4
Unit may be set to switch OFF, if presence sensor does not detect any
presence in the room for a set amount of time. The feature may be
enabled/disabled through this menu. Presence Detection feature itself may
be disabled if both Setpoint adjustment and Auto OFF settings are disabled
together.
Cooling Heating
2
Setback feature logic may be set, enabled/disabled through this menu.
3 Logic of operation is as above.
On the main screen of sub-menu, all indoor units that are on the same P1-P2 wiring are listed. (2) Click Edit, (3) Select the unit and click (4). Multiple 4
indoor units (if on the same P1-P2 wiring) is possible to be selected at once. (4) Set individual airflow direction.
84 BRC1H Service Training - Internal use only
App – Unit Settings – Individual Airflow Direction
Individual Airflow Direction depends on the type of indoor unit. It’s not APP’s feature.
7 10
6 8
5
9
Select the corresponding air outlet (5) and select the desired airflow direction (6). Repeat the setting for all desired air outlets and then click (7) Save. (8)
You may also select all outlets at once (9) and select the same airflow direction for all outlets, and save (10). You may cancel anytime.
Please refer to installation manual of indoor unit for possibilities of air flow direction.
85 BRC1H Service Training - Internal use only
App – Unit Settings – Setpoint Range
5
Set Point Range allowed on BRC1H and also on app may be set through this
menu. This setting effects BOTH the remocon and the app interface.
4
(5) Click Back to return to previous menu.
2
3 4
1
If there is Group Control, all available Indoor Units will be listed here. Air flow direction range may be limited separately for each indoor unit. This setting will
apply to available effective set range on BRC1H interface and also on app interface. (5) Click Back to return to previous menu.
2
If the indoor unit is equipped with an intelligent eye sensor, then this menu
will enable/disable draught prevention feature.
1 4
2
3
Error History may be accessed through this menu. When display for errors and warnings are disabled, they will stop appearing at main screen notification area for 48 hours.
After 48 hours these settings will go ON again. (5) Click Back to return to previous menu.
89 BRC1H Service Training - Internal use only
App – Unit Settings – Unit Number
4 4
1
2 3
Unit Number is required in case Group Control is applied to perform individual settings to each indoor unit. Unit Number is displayed on User Level but can only be changed
on Installer Level of the app. (4) Click Back to return to previous menu
90 BRC1H Service Training - Internal use only
App – Unit Settings – Unit Number
5 5 6
3
1
2
To change the unit number, (2) first click the unit you want to change the unit number. (3) Then click an empty available unit number. (4) Click Change to perform. (5) You
may cancel anytime. This setting is only applicable in Installer Mode. (6) Click Back to return to previous menu
91 BRC1H Service Training - Internal use only
App – Unit Settings – Filter Auto Clean
Self Filter Cleaning is an option an depends on the type of indoor unit. It’s not APP’s feature.
2
3
1
4
When Filter clean feature is enabled, unit cleans the filter once a day according to the timespan selected. Effective timespan is 00:00 to 24:00 in steps of 3 hours. When
“Test filter auto clean” is clicked, test will begin and status is communicated by the app. (5) Click Back to return to previous menu
92 BRC1H Service Training - Internal use only
App – Unit Settings – AirNet Address
1 3
AirNet addresses may be set also by the app. If there is a group control, you will see all units in the same P1-P2 wiring.
Effective AirNet address setting is 1 – 128. (5) Click Back to return to previous menu
93 BRC1H Service Training - Internal use only
App – Unit Settings – Group Address
2
2
2
3
1
Group addresses may be set also by the app. If there is a group control, you will see all units in the same P1-P2 wiring.
(5) Click Back to return to previous menu
94 BRC1H Service Training - Internal use only
App – Unit Settings – Field Settings
2
4 6
1
5 7
Any field setting for the indoor unit may also be set via the app. (2) On Type, select Indoor Unit (3). (4) Select the mode no you want to display or change. (5)
If there is a group control, all indoor units on the same P1-P2 wiring are available for field setting. (6) Select the unit (7)
10
8
11
Mode 20 – Setting: 2 is
selected. The value set is 2.
9
12
(8) Select the setting you want to change (9) Selection is highlighted with a triangle icon.
2 7
1
3
Mode R1 – SW7: 2 is
4 6 selected. The value set is 1.
Remote Controller Field Settings may also be set by the app. (1) As Type, select Remote Controller (2). (3) Select the remocon setting mode as R1 or R2 (4)
(5) Select the desired setting. It will be highlighted with a triangle as you select it. (6) Changes are indicated as light blue font. (7) Save once done.
Please refer to manuals of each indoor unit. These settings may vary
depending on the type of indoor unit.
9
Apply and Save the settings.
Field Settings may be active on only one interface. If field settings menu is
active on App, then it will not be accessible by remocon. If field settings menu
is active on remocon, then it will not be accessible on the app.
1
Switch ON/OFF duty rotation feature through this menu. You may also change rotation cycle time. Available set range is 6h, 12h, 24h, 48h, 72h, 96h, 168 h. (4) Click Back to
return to previous menu
10 BRC1H Service Training - Internal use only
App – Unit Settings – Test operation
2 3
1 Test Operation may be performed via the app. Result will be communicated after test is over. Test may be
cancelled any time with Stop Test Operation Button. Refer to Installer Reference Guides for more information
over test procedure of the unit. (4) Click Back to return to previous menu
101 BRC1H Service Training - Internal use only