Notes Tee602 Bode Plot
Notes Tee602 Bode Plot
Considerations:
Factorization:
K ( s z )( s z ) ... ( s z )
( s p )( s p ) ... ( s p )
1
m
n
( s 8)( s 14)
s ( s 4)( s 10)
j axis
S - plane
-14
-10
-8
x
-4
origin
0
axis
Bode Plot
It is graphical representation of transfer function
to find out the stability of control system.
It consists of two plots
Magnitude (in dB) Vs frequency plot
Phase angle Vs frequency plot
Bode Plot
Consider following T.F
G(s)
K 1( s z1 )( s z2 ) ... ( s zm )
2
s s
N
s ( s p1 )( s p2 ) ... ( s pn ) 1 2
wn wn
Put s=jw
G ( jw)
K 1( jw z1 )( jw z2 ) ... ( jw zm )
2
jw
jw
N
( jw) ( jw p1 )( jw p2 ) ... ( jw pn ) 1 2
wn wn
jw jw
N
( jw) (1 jwTa )(1 jwTb ) ... (1 jwTn ) 1 2
wn wn
Bode Plot
So
Phase Angle
Bode Plot
Magnitude in dB
20 log10 | G ( jw) | 20 log10 | K | 20 log10 | 1 jwT1 | 20 log10 | 1 jwT2 | ... 20 log10 | 1 jwTn |
Phase Angle
G ( jw) ( K ) 1 jwT1 1 jwT2 ... 1 jwTn
1 jwTa 1 jwTb ... 1 jwTm etc
Bode Plot
Type of
System
Initial Slope
Intersection with
0 dB line
0
1
2
3
.
.
.
N
0 dB/dec
-20dB/dec
-40dB/dec
-60dB/dec
.
.
.
-20NdB/dec
Parallel to 0 axis
=K
=K1/2
=K1/3
.
.
.
=K1/N
jw
jw
N
( jw) (1 jwTa )(1 jwTb ) ... (1 jwTn ) 1 2
w
w
n
n
1 1 1
1 1 1
,
, ...
,
,
Rad / sec
T1 T2 T3 Ta Tb Tc
etc
GM in dB = 20log10(1/|G(jw|) = -20log10|G(jw|
Gain cross-over frequency: Frequency where magnitude plot
intersect the 0dB line (x-axis) denoted by wg
PM in degree = 1800+angle[G(jw)]
Phase cross-over frequency: Frequency where phase plot
intersect the 1800 dB line (x-axis) denoted by wp
2. Unstable
If wg>wp => GM & PM are ve
3. Marginally stable
If wg=wp => GM & PM are zero
Determine
(i) GM
(ii) PM
(iii) Stability
1000
G ( s)
(1 0.1s )(1 0.001s )
1000
G ( jw)
(1 0.1 jw)(1 0.001 jw)
2. Find out corner frequencies
1
1
10
1000
0.1
0.001
So corner frequencies are 10, 1000 rad/sec
Phase Plot
S.N W
o
Angle (G(jw)
1
2
3
4
5
6
7
8
9
----900
-980
-134.420
-153.150
-161.360
-168.570
-172.790
-1800
1
100
200
1000
2000
3000
5000
8000
Infi
BodePlotGui.fig