Axial Pile Capacity Based On Statics Method
Axial Pile Capacity Based On Statics Method
Q = Qb + Qs
Qs
Qb
Pile Classification
Pile material
Method of Fabrication
Amount of ground disturbance during pile
instalation
Method of pile instalation into ground
Method of load transfer
METODA EVALUASI
DAYA DUKUNG AKSIAL TIANG
TUNGGAL
Superior Text
BERDASARKAN UJI
BEBAN SKALA PENUH
PENGUJIAN
TEGANGAN
TERKENDALI
PENGUJIAN
REGANGAN
TERKENDALI
RUMUS
PANCANG
PENGUJIAN
LABORATORIUM
BATUAN
MEYERHOFT
COYLE &
CASTELLO
BEREZANTEV
TANAH NONKOHESIF
PERS.
GELOMBANG
METODA
CASE
CAPWAP
PDA & PIT
PENGUJIAN
LAPANGAN
TANAH
KOHESIF
KELILING PERMUKAAN
TIANG
CARA UMUM
COYLE &
CASTELLO
DAYA DUKUNG
UJUNG
9 Su
BERDASARKAN PERSAMAAN
DINAMIS (DYNAMIC METHOD)
KELILING
PERMUKAAN TIANG
CARA
CARA
CARA
PENETRASI
STANDAR (SPT)
DAYA DUKUNG
UJUNG
MEYERHOFT
BRIAUD
PENETRASI KONUS
/ SONDIR (CPT)
DAYA DUKUNG
KELILING PERMUKAAN
MEYERHOFT
BRIAUD
MEYERHOFT
SCHMERTMAN &
NOTHINGHAM
LCPC
DAYA DUKUNG
KELILING PERMUKAAN
NOTHINGHAM &
SCHMERTMAN
Qb
Qb = qb x Ap
Qs = fs x As
where:
Qu = ultimate pile capacity
Qs
Qb
qb = cNc* + qNq*
q = D = effective vertical stress at the level of pile tip
Nc* and Nq* = the bearing capacity factors
qb = cNc* + qNq*
qb = qNq*
Soft clays
fs = Kv tan
where:
K = earth pressure coefficient
v = effective vertical stress at the depth under
consideration
Values of K
Type of piles
K value
Borred or Jetter
K0 = 1 sin
K0 s/d 1.40 K0
K0 s/d 1.80 K0
Values of v
Will increases with pile depth up to a maximum limit known
as critical depth L that depends on several factors (friction
angel, compressibility and relative density) and can be
assume L = 15B
Values of to be in the range of 0.5 to 0.8
METHOD:
The unit skin resistance in clayey soils can represented
by the equation:
fs = cu ( = imperical adhesion factor)
METHOD:
The unit skin resistance in clayey soils can represented
by the equation:
fs = ( v + 2cu)
where:
v = mean effective vertical stress
for the entire embedment
length
cu = mean undrained shear
strength ( = 0 concept)