FactoryTalk View
Site Edition
: What s new ??
Copyright 2014 Rockwell Automation, Inc. All Rights
Topics
FactoryTalk View SE System Overview, System
Limits
FactoryTalk View Network Station
FactoryTalk View Security
FactoryTalk ViewPoint Idea
Copyright 2014 Rockwell Automation, Inc. All Rights
Considerations
Domains, Workgroups, and Operating System
Considerations
Remote Desktop Services - Extending FactoryTalk
View SE with Microsoft's Remote Desktop
Services
Ethernet Network
- Applying EtherNet/IP in Real-Time Applications
And Wireless Design Considerations for Industrial
Applications
Visualization
Copyright 2014 Rockwell Automation, Inc. All Rights
System Overview
FactoryTalk View SE Overview
FactoryTalk View SE
Station
FactoryTalk View SE
Distributed
Client
s
Data
Server
s
FactoryTa
lk
Directory
Server
View
SE
Server
s
View Studio
Developmen
t Station
Copyright 2014 Rockwell Automation, Inc. All Rights
Components Block Diagram
S
Clie
E
nt
Studio
Enterpris
e
HMI
Serve
r
Alarm
Serve
r
Data
Serve
r
DHC
P
DNS
AD
FT
Director
y
CL
X
High
Availability
CL
X
Copyright 2014 Rockwell Automation, Inc. All Rights
FactoryTalk Site Edition (Local)
FactoryTalk Site Edition (Network
Distributed)
FactoryTalk Site Edition (Network
Distributed)
FactoryTalk Site Edition (Network)
FactoryTalk Site Edition (Network)
FactoryTalk Directory
FactoryTalk Services Platform
Overview
Common software
license
management for
all FactoryTalk
products
Activatio
n
Common address
lookup of
resources that
are shared among
FactoryTalk
enabled products
Common security
authority for all
FactoryTalk
components in
the system
Common
diagnostic
messaging subsystem across all
FactoryTalk
products
Director
y
Securit
y
Diagnostic
s
Comprehensive
record of any
changes made to
the
manufacturing
system
Enterprise-wide
access to realtime
manufacturing
data
Enterprise-wide
notification to
real-time alarms
and events that
require action
Aud
it
Live
Data
Alarms
and
Events
DATA SERVERS
Copyright 2014 Rockwell Automation, Inc. All Rights
Factory Talk data server option
RSLinx Enterprise **Preferred**
Live Data Server for FactoryTalk View SE and other FactoryTalk
applications (FactoryTalk
Transaction Manager, FactoryTalk Historian, FactoryTalk Metrics)
Optimized performance via TCP/IP, not DCOM
Offline browsing of Logix based controller project
Preferred Data Server for ALL Rockwell Automation controllers
3rd Party OPC Server
To communicate with non-AB controllers
KepWare Kepserver Enterprise ships with FactoryTalk View
SE
Components Block Diagram
No Activation**
Up to 10
Servers
High
Availability
Server
100,000OS
tags per server
SE
Clie
nt
Studio
Enterpris
e
HMI
Serve
r
Alarm
Serve
r
Data
Serve
r
FT
Director
y
DHC
P
DNS
AD
CLX
High
Availability
CLX
Copyrig
ht
2014
Rockwe
ll
Autom
ation,
Inc. All
Rights
Reserv
ed.
16
ALARM SERVERS
Copyright 2014 Rockwell Automation, Inc. All Rights
FactoryTalk Alarms and Events
Two different types of alarm
sources:
Software-based alarm servers poll data tags
Alarm instructions available in the
Logix family of controllers.
for alarm conditions.
The controller detects alarm conditions
and
triggers alarm events
The FactoryTalk Alarms and Events server
captures all of the controller events and
sends notification to connected clients
The Alarm server detects alarm
conditions and triggers alarm events
Information is displayed in the Alarm
Management components on the
clients
Information is displayed in the Alarm
Management components on the
clients
Supports PLC-5, SLC 500, or any thirdparty device through OPC-DA
Device
Based
Alarms
Tag-Based
Alarms
The FactoryTalk Alarms and Events server
captures all of the controller events and
sends notification to connected clients
View SE Components Block
Diagram
SE
Clie
nt
HMI
Serve
r
Studio
Alarm
Enterpris
e
Data
Serve
r
DHC
P
DNS
AD
FT
Director
y
Serve
No
Activation
r to 10
Up
Servers
High
Availability
Server OS
Max 10,000 alarms per
server
CL
X
High
Availability
CL
X
Copyrig
ht
2014
Rockwe
ll
Autom
ation,
Inc. All
Rights
Reserv
ed.
19
Device-Based Alarms
Alarm detection is in the controller
Detection down to
millisecond level
Accurate timestamp - not delayed
by alarm detection on a PC
Complete alarm configuration in
the controller
Alarm notification is event driven
from controller
No polling of alarm tags
required
Reduced network traffic
PUBLIC INFORMATION
Copyright 2014 Rockwell Automation, Inc. All Rights Reserved. 27
FactoryTalk Alarms and Events Architecture
Alarm and
Event Setup
FactoryTalk View
Summary
FactoryTalk View
Log Viewer
Database Setup
FactoryTalk View Studio
or
FactoryTalk Admin Console
FactoryTalk View
Banner
FactoryTalk View Status
Explorer
FactoryTalk View SE Client
Tag Alarm and Event
Server
OPC-DA
RSLinx
Server
External
Alarm &
Event
databases
RSLE
FactoryTalk Alarm and
Event Services
Device Alarm and Event
Server
RSLE Alarm Services
Tag-based Alarm
Detection
PLC 5, SLC
PUBLIC INFORMATION
Third Party
Controllers
Logix Family
Device-based Alarm
Detection
Copyright 2014 Rockwell Automation, Inc. All Rights Reserved. 28
Supports ISA 18.2
New Shelve buttons
available on Alarm
Enter shelve time
duration and
Factorytalk ViewpointPanelView
: WebPlus
Enabled
Visualization
with ViewPoint
Support single client connection
to a PanelView Plus
FactoryTalk View SE Station with ViewPoint
Gain web browser access to your
single station nodes
FactoryTalk View SE Server with ViewPoint
Extend your distributed system to
mobile web clients like the
Microsoft Surface Pro Tablet
PUBLIC INFORMATION
Copyright 2014 Rockwell Automation, Inc. All Rights Reserved. 35