0% found this document useful (0 votes)
20 views1 page

SPC 50126

The Process Capability Analysis Report dated 07.02.2022 evaluates the diameter of the B-BRACKET LH part produced for Neelanchal Engineering, showing a strong capability with a Cp of 5.56 and Cpk of 4.00. All measurements fall within the specified limits, with no readings above the upper specification limit (USL) or below the lower specification limit (LSL). The analysis concludes that the process is capable.

Uploaded by

hd202041
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
20 views1 page

SPC 50126

The Process Capability Analysis Report dated 07.02.2022 evaluates the diameter of the B-BRACKET LH part produced for Neelanchal Engineering, showing a strong capability with a Cp of 5.56 and Cpk of 4.00. All measurements fall within the specified limits, with no readings above the upper specification limit (USL) or below the lower specification limit (LSL). The analysis concludes that the process is capable.

Uploaded by

hd202041
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

PROCESS CAPABILITY ANALYSIS REPORT Date: 07.02.

2022

Objective:-
To know the variation on process
Customer / Supplier Neelanchal Engineering 0.05 Specification LSL 9.20 USL 9.40

Part / Product Description B-BRACKET LH 0.01 No.of decimal places in data 2

Part / Product Code D5MS-50126 0.1 Unit No.of classes α-value


Quality Parameter Diameter 0.05 5 0.05
Min Max. Average Std. Dev. Cp Cpk Sigma Level
9.32 9.35 9.328 0.006 5.56 4.00 13.50
0.006
Class Intervals Class Freq. cum.f LSL USL
9.289 -- to -- 9.295 A 0 0 -6.00 0.00 0.00 0.00
9.295 -- to -- 9.301 B 0 0 -5.00 0.00 0.00 0.00
9.301 -- to -- 9.307 C 0 0 -4.00 0.00 0.00 0.10
9.307 -- to -- 9.313 D 0 0 -3.00 0.00 0.20 1.70
9.313 -- to -- 9.319 E 0 0 -2.00 0.02 3.41 11.80
9.319 -- to -- 9.325 F 42 42 -1.00 0.16 23.80 35.79
100
9.325 9.328 9.331 G 100 142 0.00 0.50 75.00 51.20
9.331 -- to -- 9.337 H 0 142 1.00 0.84 ### 35.79
9.337 -- to -- 9.343 I 5 147 2.00 0.98
42 ### 11.80
9.343 -- to -- 9.349 J 0 147 3.00 1.00 ### 1.70
9.349 -- to -- 9.355 K 3 150 0 0 0 0 4.000 1.00 ### 00.10 5 0 3 0 0
9.355 -- to -- 9.361 L 0 150
A B C D E5.00 1.00
F ###
G H0.00 I J K L M
9.361 -- to -- 9.367 M 0 150 6.00 1.00 ### 0.00
Total= 150
No.of Reading above USL = 0
DPMO 0
No.of Reading below LSL = 0

O b s e r v a t i o n s Data Period:- 07.02.2022


9.33 9.33 9.32 9.32 9.32 9.32 9.32 9.32 9.32 9.33 9.32 9.33 9.33 9.33 9.33
9.33 9.33 9.32 9.33 9.32 9.32 9.32 9.32 9.32 9.32 9.32 9.33 9.33 9.33 9.33
9.33 9.33 9.32 9.34 9.32 9.32 9.32 9.33 9.32 9.33 9.32 9.33 9.33 9.33 9.33
9.33 9.33 9.32 9.35 9.33 9.33 9.32 9.33 9.33 9.34 9.33 9.33 9.33 9.33 9.33
9.33 9.33 9.32 9.32 9.33 9.33 9.33 9.33 9.33 9.33 9.33 9.33 9.33 9.33 9.33
9.33 9.32 9.33 9.32 9.32 9.33 9.33 9.33 9.32 9.33 9.32 9.33 9.33 9.33 9.33
9.33 9.32 9.34 9.33 9.33 9.33 9.33 9.32 9.33 9.33 9.33 9.32 9.33 9.33 9.33
9.33 9.33 9.35 9.33 9.34 9.33 9.32 9.33 9.33 9.33 9.33 9.32 9.33 9.33 9.33
9.33 9.34 9.33 9.32 9.35 9.33 9.32 9.32 9.33 9.33 9.33 9.33 9.33 9.33 9.33
9.33 9.32 9.33 9.32 9.33 9.33 9.33 9.32 9.33 9.33 9.33 9.33 9.33 9.33 9.33

Conclusions :- Process is capable

Format No - Doc No :FM/QA/21, Rev. No 00,Rev Dt- 07.02.2022

Prepared by :- Approved by(HOD-QA)