0% found this document useful (0 votes)
21 views6 pages

000-.Certificado Nfpa 701 - Tela Ignifuga Movahaus

Smart Products Service Co., Ltd. conducted a fire test on Sunshine fabric (Type: 1080-1) made of 70% PVC and 30% polyester, which passed the NFPA 701:2015 Method 1 standards for flame propagation. The testing was performed by TUV, and the results indicated that the fabric met the required criteria for weight loss and burning duration. The report was issued on October 15, 2020, confirming the fabric's suitability for use as a curtain.

Uploaded by

Richard Martinez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
21 views6 pages

000-.Certificado Nfpa 701 - Tela Ignifuga Movahaus

Smart Products Service Co., Ltd. conducted a fire test on Sunshine fabric (Type: 1080-1) made of 70% PVC and 30% polyester, which passed the NFPA 701:2015 Method 1 standards for flame propagation. The testing was performed by TUV, and the results indicated that the fabric met the required criteria for weight loss and burning duration. The report was issued on October 15, 2020, confirming the fabric's suitability for use as a curtain.

Uploaded by

Richard Martinez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Smart Products Service Co.

,Ltd
1622 Deying Mansion, No.118 Middle Jiangdong Rd.
Nanjing, Jiangsu, China
 (+86) 025 86583475  (+86) 025 86583457
[email protected]  www.fire-test.com

Testing product: Sunshine fabric, Type: 1080-1, Material: 70% PVC + 30% polyester, Structure:
PVC covered polyester fabric, Color: White, Density: 460g/m 2, Intend use: Curtain

Standard: NFPA 701:2015 Standard Methods of Fire Tests for Flame Propagation of
Textiles and Films - Method 1

Testing Lab: TUV (the lab is recognized by CNAS with number L6069)

Date of Issue: 2020-10-15

Test Data:

Test Items Certificate ID code Customer ID code Test results


NFPA 701:2015
TC.20.09.004928 2501 Pass
Method 1

Conclusion: the test result indicate to meet with the requirements of


NFPA 701:2015 Method 1.

Smart Products Service Co.,Ltd www.fire-test.com Tel: (+86)-25-8658 3475


Value-added services:

You can search for “firetest” or scan the QR code below to follow or our WeChat
Official/Public Accounts to learn more about the relevant standards and regulations for fire
retardant testing of rail transit vehicles or building materials, moreover, and you can also
ask for supporting, search for a result or reports and certificate enquiries, standards
sharing and downloads on the WeChat Official/Public Accounts. Join us!

Smart Products Service Co.,Ltd www.fire-test.com Tel: (+86)-25-8658 3475


Smart Products Service Co.,Ltd
1622 Deying Mansion, No.118 Middle Jiangdong Rd.
Nanjing, Jiangsu, China
 (+86) 025 86583475  (+86) 025 86583457
[email protected]  www.fire-test.com

NFPA 701-Fire tests for flame propagation of textiles and films

NFPA 701—Standard methods of fire tests for flame propagation of textiles and films.

Testing methods: according to product weight and the surface coating.

NFPA 701 Method 1:


Scope:
(1) Table Skirts
(2) Table Linens
(3) Display booth separators
(4) Textile wall hangings
Not apply to the specimens having an area density greater than 700g/m 2
Not apply to the Vinyl-coated fabric.

Specimen: 400mm*150mm *10pcs


The specimen is vertically hanged. The specified gas flame shall be applied to the center
of the lower edge of the specimen for 45 seconds.

Criteria:
(1) The fragments and residues that fall to the floor of the test chamber shall not continue
to burn for more than an average of 2 seconds.
(2) The average weight loss of the 10 specimens in a sample shall be 40 percent or less.

NFPA 701 Method 2:


Apply to the specimens having an area density greater than 700g/m 2
Apply to the Vinyl-coated fabric.
Apply to the plastic films.

Fail Criteria:
(1) When any specimen continues flaming for more than 2 seconds after the test flame is
removed from contact with the specimen, the material shall be recorded as having failed
the test.
(2) When the length of char of any individual folded specimen exceeds 1050 mm, the
material shall be recorded as having failed the test.
(3) When the char length of any single flat specimen exceeds 435mm, the material shall be
recorded as having failed the test.
(4) The fragments and residues that fall to the floor of the test chamber shall not continue
to burn for more than 2 seconds.

Smart Products Service Co.,Ltd www.fire-test.com Tel: (+86)-25-8658 3475


Report No. TC.20.09.004928

Date of Issue 10/15/2020

Description of the test subject:

Sample Description Photo


Sample Description: Sunshine fabric

Type: 1080-1

Material: 70%PVC+30% polyester

Structure: PVC covered polyester


001
fabric

Color: White

Density: 460g/m2

Intend use: curtain

Receipt Date of Sample: 09/30/2020

Date of Testing: From 09/30/2020 to 10/15/2020

Sample submitted: The sample(s) was (were) submitted by applicant and identified.

Conclusion:

Test Items
Result
No. Items Standard

Methods of Fire Tests For Flame NFPA 701:2015


1 Pass
Propagation of Textiles and Films Method 1

Note: (1) General Terms & Conditions as mentioned overleaf,(2)The results relate only to the items tested,(3)The test report shall not be reproduced except in
full without the written approval of the company. (4) Samples are tested as received.

Laboratory: Phone: +86/ (0) 519- 8123-9872 No. 164, Wuyi Road ,Lucheng Street, Wujin
TÜV SÜD SW Rail Transportation Fax: +86/ (0) 519- 8123-9872 ext.123 District, Changzhou city, Jiangsu Province,
Technology (Jiangsu) Co., Ltd. E-mail: Haixin.Zhao @tuvsud.com
www.tuvsud.com 213015 P.R. China Page 1 of 3
Report No. TC.20.09.004928

Date of Issue 10/15/2020

Test Results

NFPA 701:2015 Standard Methods of Fire Tests for Flame Propagation of Textiles and Films- Method 1

1. Sample description
Size of sample 150mm × 400mm 10pcs 460 g/m2

Conditioning at least 30 minutes at 105℃±3℃

2. Test results
Fragments or
Specimen Mass of specimen Mass of specimen Mass loss After flame residues of
Before test After test
No. (Percent) time (s) specimens that fall
(g) (g)
to the floor (s)
1 29.8 14.9 50.0 0 0

2 29.1 17.2 40.9 0 1

3 30.4 20.0 34.2 0 1

4 30.9 18.8 39.2 0 0

5 29.6 19.5 34.1 0 0

6 31.1 20.5 34.1 0 1

7 30.7 19.4 36.8 0 0

8 29.5 21.2 28.1 0 0

9 29.7 20.7 30.3 0 1

10 30.5 19.8 35.1 0 0

Average -- -- 36.3 0 0.4


Standard -- -- --
-- 5.8
Deviations

Criteria for test method 1 (Chapter 10):


1. Fragments or residues of specimens that fall to the floor of the test chamber shall not continue to burn for
more than an average of 2 seconds per specimen for the sample of 10 specimens.
2. The average weight loss of the 10 specimens in a sample shall be 40 percent or less.

Note: (1) General Terms & Conditions as mentioned overleaf,(2)The results relate only to the items tested,(3)The test report shall not be reproduced except in
full without the written approval of the company. (4) Samples are tested as received.

Laboratory: Phone: +86/ (0) 519- 8123-9872 No. 164, Wuyi Road ,Lucheng Street, Wujin
TÜV SÜD SW Rail Transportation Fax: +86/ (0) 519- 8123-9872 ext.123 District, Changzhou city, Jiangsu Province,
Technology (Jiangsu) Co., Ltd. E-mail: Haixin.Zhao @tuvsud.com
www.tuvsud.com 213015 P.R. China Page 2 of 3
Report No. TC.20.09.004928

Date of Issue 10/15/2020

3. No individual specimen’s percent mass loss shall deviate more than 3 standard deviations from the mean
for the 10 specimens.
4. When a retest is required, no individual specimen’s percent mass loss in the second set of specimens shall
deviate from the mean value by more than 3 standard deviations calculated for the second set.
5. When a sample does not demonstrate passing performance in accordance with all of the conditions
indicated above, the material shall be recorded as having failed Test Method 1.

Conclusion: The tested sample “As received” meets the requirements of Test Method 1 of NFPA 701:2015.

Statement:The test results relate to the behaviour of the test specimens of a product under the particular
conditions of the test; they are not intended to the sole criterion for assessing the potential smoke and toxicity
hazard of the product in use. Test results are just for internal reference.

TÜV SÜD SW Rail Transportation Technology (Jiangsu) Co., Ltd.

Drafted by: Approved by:

Wayne Wang Shen hui

-End of Report-

Note: (1) General Terms & Conditions as mentioned overleaf,(2)The results relate only to the items tested,(3)The test report shall not be reproduced except in
full without the written approval of the company. (4) Samples are tested as received.

Laboratory: Phone: +86/ (0) 519- 8123-9872 No. 164, Wuyi Road ,Lucheng Street, Wujin
TÜV SÜD SW Rail Transportation Fax: +86/ (0) 519- 8123-9872 ext.123 District, Changzhou city, Jiangsu Province,
Technology (Jiangsu) Co., Ltd. E-mail: Haixin.Zhao @tuvsud.com
www.tuvsud.com 213015 P.R. China Page 3 of 3

You might also like