Cobexp710 Um
Cobexp710 Um
User manual
Document number: 98-140012-B
Release date: 4 February 2014
Disclaimer
Any responsibility or liability for loss or damage in connection with the use of this product and the
accompanying documentation is disclaimed by Thrane & Thrane A/S. The information in this manual is
provided for information purposes only, is subject to change without notice and may contain errors or
inaccuracies. Manuals issued by Thrane & Thrane A/S are periodically revised and updated. Anyone
relying on this information should acquire the most current version e.g. from www.cobham.com/satcom
or from the distributor. Thrane & Thrane A/S is not responsible for the content or accuracy of any
translations or reproductions, in whole or in part, of this manual from any other source.
Thrane & Thrane A/S is trading as Cobham SATCOM.
Copyright
© 2014 Thrane & Thrane A/S. All rights reserved.
Trademark acknowledgements
• Inmarsat is a registered trademark of the International Maritime Satellite Organisation (IMSO) and
is licensed by IMSO to Inmarsat Limited and Inmarsat Ventures plc.
• Other product and company names mentioned in this manual may be trademarks or trade names of
their respective owners.
98-140012-B ii
Safety summary 1
The following general safety precautions must be observed during all phases of operation, service
and repair of this equipment. Failure to comply with these precautions or with specific warnings
elsewhere in this manual violates safety standards of design, manufacture and intended use of the
equipment. Cobham SATCOM assumes no liability for the customer's failure to comply with these
requirements.
Do not operate in an explosive atmosphere
Do not operate the equipment in the presence of flammable gases or fumes. Operation of any
electrical equipment in such an environment constitutes a definite safety hazard.
Keep away from live circuits
Operating personnel must not remove equipment covers. Component replacement and internal
adjustment must be made by qualified maintenance personnel. Do not replace components with
the power cable connected. Under certain conditions, dangerous voltages may exist even with the
power cable removed. To avoid injuries, always disconnect power and discharge circuits before
touching them.
Do not service alone
Do not attempt internal service or adjustments unless another person, capable of rendering first aid
resuscitation, is present.
Do not substitute parts or modify equipment
Because of the danger of introducing additional hazards, do not substitute parts or perform any
unauthorized modification to the equipment.
Keep away from antenna front
This device emits radio frequency energy when switched on. To avoid
injury, keep a minimum safety distance of 1 m from the antenna front
when the EXPLORER 710 is on.
For information on the safety distance from the transceiver (WLAN), see
the FCC/IC Radiation Exposure statement on the next page.
Garder à l'écart de l'avant de l'antenne
Le présent appareil émet des radiofréquences lors de son utilisation. Afin d'éviter tout risque pour la
santé, une distance minimale de 1 mètre est nécessaire entre l'utilisateur et l'avant de
l'EXPLORER 710.
Pour plus d'informations à propos de la distance de sécurité avec l'appareil (WLAN), veuillez
consulter Déclaration de l’IC sur l'exposition aux radiations sur la page suivante.
Only use approved batteries from Cobham SATCOM
Use of non approved batteries may result in explosion, fire, electrical shock or injury.
Observe marked areas
Under extreme heat conditions do not touch areas of the EXPLORER 710
that are marked with this symbol, as it may result in injury.
The terminal has been designed for full usability meaning that there are
no restrictions to which interfaces can be used simultaneously. This
means that you can use all the interfaces at once at any temperature
98-140012-B iii
within -25 to 55 C. Be aware that the terminal will get very hot when it is operated at 55 C with
all interfaces active and it is therefore marked with a heating label.
98-140012-B iv
Antenna Safety Instructions
Antenna Gain
Antenna Mounting
The antenna supplied by the manufacturer must be located such that during radio
transmission, no person or persons can come closer than the above indicated minimum
safe distance to the front face of the antenna, i.e. 1 m.
L'antenne fournie par le fabricant doit être placée de telle sorte que, durant les
transmissions radio, personne ni aucun groupe de personnes ne puisse s'approcher à une
distance inférieur à la distance de sécurité minimal indiquée ci-dessus, c.-à-d., 1 m.
To comply with current FCC RF Exposure limits, the antenna must be installed at or
exceeding the minimum safe distance shown above, and in accordance with the
requirements of the antenna manufacturer or supplier.
Antenna Substitution
Do not use any other antenna than the models supplied or recommended by the
manufacturer. You may be exposing people to excess radio frequency radiation. You
may contact the manufacturer for further instructions.
Radiation Warning
You, as the qualified end-user of this radio device, must control the exposure conditions
of bystanders to ensure the minimum separation distance (above) is maintained
between the antenna and nearby persons, for satisfying RF Exposure compliance. The
operation of this transmitter must satisfy the requirements of General Population/
Uncontrolled Environment. Only use the terminal when persons are at least the
minimum distance from the front face of the antenna.
98-140012-B v
About this manual
Intended readers
This manual is a user manual for the EXPLORER 710. The manual is intended for anyone
who is using or intends to use the EXPLORER 710. No specific skills are required to
operate the EXPLORER 710. However, it is important that you observe all safety
requirements listed in the Safety summary in the beginning of this manual, and
operate the EXPLORER 710 according to the guidelines in this manual.
Related documents
The following documents are related to this manual and to the EXPLORER 710 system.
Document
Title and description
number
Typography
98-140012-B vi
Table of Contents
98-140012-B vii
Table of Contents
98-140012-B viii
Table of Contents
98-140012-B ix
Table of Contents
98-140012-B x
Table of Contents
Troubleshooting ........................................................................................................................77
Troubleshooting guide ....................................................................................................................77
Status signalling .................................................................................................................................83
List of messages .................................................................................................................................84
Log files ..............................................................................................................................................86
Diagnostics report .............................................................................................................................86
Call log and data log .........................................................................................................................86
App. B Conformity
CE (R&TTE) ...........................................................................................................................................96
IC ...............................................................................................................................................................96
FCC ...........................................................................................................................................................97
Glossary ......................................................................................................................................................................99
Index ...................................................................................................................................................................102
98-140012-B xi
Chapter 1
General description
The EXPLORER 710 is a handy portable terminal supporting simultaneous voice and data
communication over BGAN. It provides versatility and high speed access with multiple
interfaces for countless applications. Just connect your phone, laptop, smartphone or tablet,
point the antenna towards the BGAN satellite - and you are online.
The EXPLORER 710 provides access to the highest bandwidth available on the BGAN network.
With BGAN HDR (High Data Rate) you get a portfolio of four channel streaming rates including
symmetric and asymmetric options so you only pay for the data you need. The system offers
multi-user as well as single-user functionality, making it a flexible solution for a variety of
applications, such as:
• Broadcasting
• Internet browsing
• E-mail
• Phone services
• Large file transfers
Features
Full duplex, single or multi-user, standard data up to 492 kbps
Support for streaming data at 32, 64, 128, 176, 256 kbps, HDR (asymmetric or symmetric)
and BGAN X-Stream
Standard LAN w. PoE, WLAN, ISDN and Phone ports and USB Host interface
Built-in web interface allowing you to manage your calls and customize the terminal to your
specific needs, using a smartphone, computer or tablet.
Overview of interfaces
The EXPLORER 710 provides a number of interfaces for connection of various types of
computers, phones and other equipment.
Smartphone
Tablet
WLAN
LAN
ISDN or
Phone
Using the EXPLORER 710 on page 21 describes how to use each of the available interfaces.
The EXPLORER 710 is designed for minimum power consumption. This means that functions
that are not currently used will automatically go into a “sleep mode” to minimize the power
consumption. In addition to this automatic sleep mode function, you can disable each of the
interfaces if they are not currently used. Note, however, that you will not be able to use these
interfaces until you enable them again. For information on how to enable/disable interfaces,
see Enabling or disabling an interface on page 22.
Overview
The EXPLORER 710 is a compact unit comprising a transceiver with a detachable antenna,
compass, display and keypad, all in one unit.
Transport lock
Antenna
for BGAN
and GNSS
Antenna for
Display and
Wireless LAN
keypad
Compass
Battery Connectors
SIM card
(behind the battery)
3 4 5 6 7
2 9 1 8
1. Menu: Opens the display menu. For a menu overview, see next page.
2. Connect: Allows you to start a data connection.
3. Signal strength: Shows the signal strength of the satellite connection and whether the
connection is global beam (G), regional beam (R) or narrow beam (N). Press OK to see the
GPS position.
4. Interfaces on/off: Allows you to switch the interfaces on or off. Disabled interfaces are
crossed out.
5. Warning: Shows if there are warning messages. Press OK to see the messages.
6. Battery status: Shows remaining time for the internal battery and the external battery (if
connected).
7. Keypad for navigation: Allows you to move between the available options (arrow keys) and
select them (OK).
8. Status indicator: Shows status of the EXPLORER 710. For information on functions, see
Status indicator on page 83.
9. Status text: Shows the current status of the EXPLORER 710 and the network connection.
For example, the text may show the status during start-up (see The registration procedure
on page 17).
Display menu
/(9(/
/(9(/
/(9(/
/(9(/
%5,*+71(66
/(9(/
7,0(287
(;,7 /(9(/
32,1712: /(9(/
6(77,1*6 ',63/$<
3523(57,(6 32:(58302'( $872 6(&
+(/3'(6.
0$18$/ 6(&
(9(176
0,1
0,1
,3$''5(66
0,1
+$5':$5(
81,76(512
62)7:$5(
+3$6(512
,0(,
0$&)25/$1
0$&)25:/$1
User interfaces
The keypad and display are used for pointing the antenna, starting and stopping data
sessions, enabling or disabling interfaces and for displaying status and changing simple
parameters. To obtain full access to all features and for ease-of-use, you should use a computer
or smartphone and the web interface.
The web interface is a built-in web interface for easy configuration and daily use. The web
interface is accessed from a computer, smartphone or tablet connected to the EXPLORER 710,
using an Internet browser. No installation of software is needed. For further information on the
web interface, see Using the web interface on page 39.
A smartphone app, EXPLORER Connect, is also available. The app includes a SIP function
that enables you to make calls to and from your smartphone over the satellite network using
the EXPLORER 710 terminal. It also includes the complete feature set from the built-in web
interface of the terminal, allowing you to set up and use the terminal with your smartphone.
With AT commands you can configure and control the EXPLORER 710 from a computer
using a Telnet session. For further details see To access the terminal using AT commands on
page 29.
Antenna
The white part of the EXPLORER 710, including the support bracket, is the detachable antenna
module. The antenna module comprises a GNSS (Global Navigation Satellite System) antenna
and a BGAN antenna.
A Wireless LAN antenna is located on the transceiver unit.
Compass
The EXPLORER 710 also provides a compass to help positioning the antenna. For further
information on how to use the compass, see To point the antenna on page 16.
Battery
The EXPLORER 710 comes with a rechargeable battery, which is easily inserted. The battery is
automatically recharged when power is applied to the EXPLORER 710. The Status indicator
shows that the battery is charging. See User interfaces on page 6.
Time between recharging depends on the use. The display shows estimated time left for the
battery.
SIM card
The EXPLORER 710 requires a SIM card to go online. Without a SIM card you can still configure
the terminal and you may be able to make emergency calls if the network allows it, but you
cannot make normal calls nor access the internet.
Getting Started 2
Initial inspection
Inspect the shipping carton immediately upon receipt for evidence of damage during
transport. If the shipping carton is severely damaged or water stained, request that the carrier's
agent be present when opening the carton. Save the carton packing material for future use.
After unpacking the system, inspect it thoroughly for hidden damage and loose components or
fittings. If the contents are incomplete, if there is mechanical damage or defect, or if the
system does not work properly, notify your dealer.
1. Locate the SIM slot on the same side where the battery is inserted.
2. Insert the SIM card into the SIM slot with the chip
side facing up.
3. Press gently until it clicks.
Note The battery should not be partially charged too often. For further information on the
battery, see Maintenance on page 74.
Do as follows:
Note Before using the terminal the first time: to ensure accurate information on the battery
capacity you should fully charge, then fully discharge the battery, and finally recharge
the battery while it is inserted in the terminal. The EXPLORER 710 can be used during
the discharging process, but the remaining battery capacity may not be displayed
correctly.
Note For protection of the transceiver, always leave the battery inserted. Only remove the
battery to replace it.
Note When the SIM card is removed you cannot make calls or data sessions, but you can
still use the display menu system and the built-in web interface to set up the terminal.
Connecting cables
Connectors
The connector panel is placed on the side of the EXPLORER 710 and has the following
connectors:
LAN1 ISDN
LAN2
Phone (PoE)
DC in
External battery
To connect power
When you connect external power to the DC input, the battery is charged while maintaining
normal operation.
DC input
Automatic power up
The default behaviour of the EXPLORER 710 is to power up automatically when you connect
external power. If you wish, you can change this power up mode, so that the EXPLORER 710 is
only powered if the Power button is pressed.
For further information on power up mode, see Automatic power up on page 37.
Note You may not need a SIM PIN for your terminal. If you are asked for a PIN and you
select Cancel, you cannot communicate on the BGAN network, but you can access all
terminal settings.
To enter the SIM PIN using the display and keypad, do as follows:
1. When the display shows Enter PIN?, highlight the text using the arrow keys and press OK.
If you select Cancel, the startup procedure is continued, but you will not be able to make
calls or data sessions over the satellite network. See the previous section.
For an overview of the display and keypad, see Display and keypad on page 5.
For information on how to enter the PIN in the web interface, see To enter the SIM PIN on
page 43.
Note You can choose to cancel pointing. In this case you cannot communicate on the
BGAN network, but you can access all terminal settings.
Before pointing
Before pointing the antenna you can use the coverage map below to find your approximate
location in relation to the satellites. Then you can use the compass to find the pointing
direction to the closest satellite.
The 3 Inmarsat satellites are positioned above the equator, at the centre of each “footprint”.
90°
80°
70°
60°
50°
40°
30°
20°
10°
0°
10°
20°
30°
40°
50°
60°
70°
80°
90°
180° 160° 140° 120° 100° 80° 60° 40° 20° 0° 20° 40° 60° 80° 100° 120° 140° 160° 180°
3. Slowly rotate and tilt the EXPLORER 710 antenna to find the highest possible signal
strength.
CAUTION! After accepting the signal strength, keep the minimum safety
distance of 1 m from the antenna front face. The antenna may radiate
microwave power as soon as the signal strength is accepted.
The EXPLORER 710 now starts to establish a connection to the BGAN network.
Note By default, the EXPLORER 710 automatically connects to the Internet when you
connect equipment to the LAN or WLAN interface (Standard data connection).
If you are not going to use the LAN/WLAN connection, remove the cable or disable the
interface to avoid being charged for any transmission through this interface.
You may need to point the antenna again later, e.g. if the terminal has been moved or the
signal is blocked.
To start the pointing process again, do as follows:
Display: Select and select Point now. Then go through the pointing process as described
in the previous section.
web interface: Select from the top right corner and select Start. Then go through the
pointing process as described in the previous section, but click Accept in the web interface
instead of OK in the display.
Example: To call Cobham SATCOM in Denmark (+45 39558800) from an analogue phone,
dial 00 45 39558800 #
Note There are two voice numbers, one for 3.1 kHz audio and one for Standard voice.
Example: If you are calling from Denmark and the mobile number for 3.1 kHz audio is
870782112345 on your EXPLORER 710, and you want to make a call to the
EXPLORER 710 using 3.1 kHz audio, dial 00 870 782112345.
Note For the LAN interface to work without any further setup, your computer must be set
up to obtain an IP address and DNS server address automatically.
Do as follows:
1. Connect a LAN cable between your computer and LAN#1 or LAN#2 on the EXPLORER 710.
1. Separate the antenna from the transceiver as described in To detach the antenna
(optional) on page 9.
2. Mount the EXPLORER 710 antenna on a pole or a wall, for example using the Pole mount
kit.
3. Connect the antenna cable between the antenna and the transceiver.
4. Start up the EXPLORER 710 and point the antenna as described in To point the antenna on
page 16.
User interfaces
The following user interfaces are available when using the EXPLORER 710
• Phone
• ISDN
• LAN
• WLAN
• USB (Host)
Note By default, only the LAN interface is enabled. However, you can enable or disable each
of the interfaces independently
1. In the top of the display, locate the interface you want to enable or disable.
WLAN ISDN LAN Phone USB
2. Use the arrow keys on the keypad to highlight the interface you want to enable or disable.
Note It may take some seconds to enable an interface. When the icon stops pulsating
and is no longer crossed out, the interface is enabled.
Note By default, only the LAN interface is enabled. However, you can enable or disable each
of the interfaces independently
1. Connect your smartphone, tablet or computer to the EXPLORER 710, using the LAN or
WLAN interface. See:
• To connect to the LAN interface on page 25
• To connect to the WLAN interface on page 24
2. To access the web interface, open your browser and type ut.bgan in the address bar, or
type the IP address of your EXPLORER 7101 (default IP address: 192.168.0.1).
For further information on the web interface, see Using the web interface on page 39.
1. You find the IP address in the display menu system by entering the menu and selecting
PROPERTIES > IP ADDRESS.
3. When the web interface opens, click (Control panel) from the bottom right corner of
the page.
4. Locate the tile with the interface you want to enable or disable.
• means the interface is disabled.
• means the interface is enabled.
5. To enable or disable the interface, click the tile and select or clear Enable.
6. Click Save.
Note It may take some seconds to enable the interface. When the icon changes to the
enabled icon shown in step 4., the interface is enabled.
Overview
The following interfaces are available for connecting computers, smartphones or tablets:
• WLAN
• LAN
Power
Interface Amount of setup Range
consumption
WLAN High Some setup necessary on Wireless connection.
your WLAN device and in Up to 100 m depending on the
the web interface of the transmitter in the computer and
EXPLORER 710 on the transmission conditions.
Router function
The terminal has a router function which routes traffic between the local network connected
to the terminal and the BGAN network connection (also called PDP context on the BGAN
network).
The router contains NAT (Network Address Translation) which allows sharing of a public IP
address between a number of local network users.
The EXPLORER 710 has two LAN connectors. If more than one LAN or WLAN user is connected
to the EXPLORER 710, the terminal should be in Router mode (default). Refer to Configuring
the LAN interface on page 49 and User group settings (LAN and WLAN) on page 52.
To connect to the LAN interface, use a shielded cable mounted with an RJ-45 connector.
For specifications, refer to LAN interface, 2-port on page 92.
For the LAN interface to work without any further setup, the computer must be set up to
obtain an IP address and a DNS server address automatically.
This section does not describe configuration of the LAN interface. For information on
configuration, see Configuring the LAN interface on page 49.
To connect to the LAN interface, do as follows:
2. Connect the other end of the cable to one of the LAN connectors on the EXPLORER 710.
Important The ISDN interface and the LAN interface use the same connector type. Be
careful not to connect to the wrong interface.
If the EXPLORER 710 is registered on the BGAN network, and automatic activation is enabled in
the terminal, the connection to the Internet is established automatically. The status text in the
display shows if there is an active data connection.
2. Start up the terminal as described in Starting up the EXPLORER 710 on page 15.
3. Use the arrow keys to highlight the connection icon in the bottom left corner of the
display.
Note It may take some time to start up the connection. The display shows the status while
the connection is being established and when it has been started.
If the connection fails, the display shows an error message.
For information on how to start and stop data connections with the web interface, see To start
and stop data connections on page 45.
Note You cannot see in the display nor in the web interface if a PPPoE connection is active!
Overview
You can establish a PPPoE connection to the BGAN network using the EXPLORER 710 system.
Use PPPoE if you want to control your connection independently of the web interface and the
Thrane IP Handset.
Possible applications are:
• Connecting a router
• Connecting broadcast equipment, optionally through a PC
• Establishing a Picocell for the use of cell phones
The following drawing shows connections managed through PPPoE and web interface
respectively.
PPPoE
Router connection
PPPoE
connection PDP Context, up to 11
PPPoE
PC and/or broadcast equipment connection
BGAN terminal
Built-in
web
interface
Pico cell
User PC 1 User PC 2 IP
Handset
How to configure your equipment depends on the type of equipment. Refer to the user
documentation of the equipment. As a minimum, you need to configure the following
parameters in your equipment in order to make PPPoE work with the terminal:
• User name and password.
The user name and password can be left blank (or insert user name: void and password:
void). Then the registration on the Access Point is most commonly done in such a way that
the data connection is established with a dynamic IP address from the airtime provider.
To request a static IP (if subscribed to) from the Access Point you must type in the user
name and password from your airtime subscription.
Note for MAC OS: User name and password are required. Use user name void and
password void. This works for some ISPs. Contact your airtime provider for further
information.
• For setups that have a check box for “Enable LCP extensions”, deselect this.
No further configuration is needed to make a Standard IP data connection to the Internet.
See the table below for information on how to configure specific services for your PPPoE
connection.
If you need a certain service, for example a Streaming class, you must type in a specified text
string when asked for a service name. The following table shows the service names supported
by the terminal.
XBB:<AT String> This allows the PPPoE clients to enter a full AT context
activation string.
Examples:
XBB:AT+CGDCONT=1,ip,”bgan.inmarsat.com”
XBB:AT+CGEQREQ=1,1,64,64,64,64
There are three steps you must go through before you can access the terminal from a remote
location:
1. Set up the terminal for control from a remote location as described in Remote
management on page 67.
3. Note the terminal’s external IP address, found in one of the following ways:
• If you are using SMS activation and you have selected SMS confirmation, you will
receive an SMS with the IP address.
• Otherwise, connect a computer locally to the terminal and start the web interface. The
external IP address of the terminal is shown in the Dashboard in the tile with the
connection you started in the previous step.
This is the IP address you must use afterwards to access the terminal.
Note If Static IP is included in your airtime subscription, we recommend using this static
public IP address for the terminal in order to provide easy access to the terminal. To
use the static IP address, you must set the APN source to SIM default. For details, see
User group settings (LAN and WLAN) on page 52.
To be able to activate a data connection on the terminal from a remote location, the terminal
must be set up as described in Remote access with SMS on page 68.
Send an SMS to the mobile number of the terminal. The text in the activation SMS must have
the following format for activating and deactivating a connection:
• ACTIVATE <name of network user group >:<name of profile> <password>
• DEACTIVATE <name of network user group>:<name of profile> <password>
• <name of network user group>: default group
• <name of profile> standard (presently, only standard is supported)
• <password> Defined in the web interface under Advanced > Remote activation.
Example: To activate a connection for remote management with the standard data
connection and password=1234567890, send an SMS to the terminal with the
text: ACTIVATE default group:standard 1234567890
If you have selected SMS confirmation, you receive a response including the IP address to use
when you access the terminal from a remote location (see the next two sections).
Example: A confirmation SMS after sending an activation SMS may look like this:
Activation: Succeeded,. IP 161.30.181.31
Note The web interface may take a long time to load the pages if your Internet connection
speed is slow.
After preparing the terminal as described in the previous sections, do as follows to access it:
3. In the address bar of your browser, enter the IP address of the terminal followed by a colon
and the port number
http://<ip address>:<incoming port>.
• <ip address> is the address from step 3. in the previous page
• <incoming port> is the port you defined in Remote management on page 67
Example: If the IP address of the terminal is 161.30.180.12 and the incoming port number
defined in the Remote management page in the web interface is 8080, enter
http://161.30.180.12:8080.
You should now be connected to the built-in web interface of the terminal.
After preparing the terminal for remote management as described in the previous sections,
access the terminal as described in To access the terminal using AT commands on page 29.
Using a phone
Call types
Definition
The phone connection can be either a Standard voice connection or a 3.1 kHz audio
connection.
• For outgoing calls, the call type is Standard voice by default.
You can change the call type for your call to 3.1 kHz audio by dialling 2* before the
number.
• For incoming calls, you can set up in the web interface which call types you want to receive
on the Phone, ISDN or LAN/WLAN interface (IP handset). Only the call types selected for
an interface are received on that interface.
When receiving calls, the mobile number determines which call type is used. In your airtime
subscription you have one number for 3.1 kHz audio and one number for Standard voice.
Remember that the call is only received on an interface if the call type used is selected for that
interface.
For information on how to set up the call types in the web interface, see Configuring the
Phone interface on page 53.
Note Make sure your phone has an integrated SIP client. Cobham SATCOM offers the
EXPLORER Connect smartphone app with a SIP client. You can also find other SIP
applications available for download on the Internet.
If it is the first time you connect your phone to the LAN or WLAN interface for making calls,
you must first set up the SIP server details in your smartphone. For information how, see the
user documentation for your smartphone and for the SIP application. You may be asked to
enter some of the following details:
• SIP server address and port: Default address: 192.168.0.1, Port: 5060
• User name: Local no. in EXPLORER 710 (0501 to 0516)
• Password: Default same as user name
• Codec priority: Highest priority codec type: G.711
Note The user name and password must match the IP handset settings in the web interface
of the EXPLORER 710. See Managing IP handsets or smartphones on page 55.
For details on initial setup of your smartphone and the EXPLORER 710, see
• The documentation for your handset
• First time SIP setup on page 31
• Managing IP handsets or smartphones on page 55
To use your phone to make calls through the EXPLORER 710 using WLAN, do as follows:
Note Make sure your IP handset complies with PoE class 2 (7 W).
For details on initial setup of your IP handset and the EXPLORER 710, see
• The documentation for your handset
• First time SIP setup on page 31
• Managing IP handsets or smartphones on page 55
To connect a wired IP handset, do as follows:
Note Make sure PoE is enabled in the terminal. See Configuring the LAN interface on
page 49.
2. Connect the LAN cable between the IP handset and the connector LAN #1 on the
EXPLORER 710.
When the IP handset is powered and ready, you should now be able to make and receive calls
over BGAN.
To connect a phone to the Phone connector, you need an analog telephone cable with an RJ-
11 connector. For specifications and pin-out, refer to Phone interface on page 90.
Do as follows:
2. Connect the other end of the cable to the Phone connector on the EXPLORER 710.
3. Power up the EXPLORER 710 and point the antenna as described in To point the antenna
on page 16.
To connect a phone or modem to the ISDN connector, you need an ISDN cable with an ISDN
connector. For specifications and pin-out, refer to ISDN interface on page 91.
The ISDN interface supports connection of up to 4 devices. However, if you are going to
connect more than one device, the devices must be self-powered. The ISDN interface can
supply maximum 1 W.
The BGAN Core network presently only supports one 64 kbps ISDN channel per subscription.
Do as follows:
3. Power up the EXPLORER 710 and point the antenna as described in To point the antenna
on page 16.
First connect your phone to the relevant interface. For further information, see:
• Smartphone: To connect your smartphone for making calls on page 32
• Analogue phone: To connect an analogue phone on page 33
• ISDN phone: To connect an ISDN phone or modem on page 34
• IP handset: To connect a wired IP handset for making calls on page 32
To receive a call
By default, all devices connected to the EXPLORER 710 will ring when one of the mobile
numbers is called. Note however, that this depends on the call type settings. See Call types on
page 31.
Information on missed calls is stored in the call log. You can see the call log in the web
interface (Control panel > Log > Call log).
To make a call to a phone connected to the EXPLORER 710, dial + <Mobile number>
• + is the prefix used in front of the country code for international calls. This is 00 when
calling from countries in Europe and from many other countries.
• Mobile number. The first part of the mobile number is always 870, which is the “country
code” for the BGAN system. For information on the mobile numbers, refer to your airtime
subscription.
Note There are two mobile numbers, one for 3.1 kHz audio and one for Standard
voice.
Overview
There are a number of local numbers and dialing functions available in the EXPLORER 710.
The following list shows the allocated local numbers and special-purpose numbers for the
EXPLORER 710.
Number Function
00 followed by one of the numbers Short dial phone numbers in phone book.
1-199 and # or off-hook key
0400 followed by # or off-hook key Local call broadcast to all ISDN phones.
Apart from the numbers above, the EXPLORER 710 uses the following dialing prefixes:
• 1* before the phone number will force the connection to use Standard voice.
• 2* before the phone number will force the connection to use 3.1 kHz audio.
• #31# before the phone number will hide the callers phone number to the recipient.
• *31# before the phone number will show the callers phone number to the recipient where
it would otherwise be hidden, e.g. because the number is an ex-directory number.
You can make local calls between phones connected to the EXPLORER 710. For an overview of
the available numbers, see the table in the previous section.
To make a local call, dial <local number> followed by # or off-hook key.
4. Select the period of time the display light should stay on after the last key is pressed.
Automatic power up
The default behaviour of the EXPLORER 710 is to power up automatically when you connect
external power. If you wish, you can change this power up mode, so that the EXPLORER 710 is
only powered if the Power button is pressed. To switch between automatic and manual power
up of the terminal, do as follows:
This chapter describes how to use the web interface to operate, set up and configure your
system. It has the following sections:
• Introduction
• Entering the SIM PIN in the web interface
• Pointing the antenna
• Using the Dashboard
• Viewing status
• The Control panel
• Using the Logs
• Configuring the LAN interface
• Configuring the WLAN interface
• Port forwarding
• User group settings (LAN and WLAN)
• Configuring the Phone interface
• Configuring the ISDN interface
• Configuring the USB interface
• Managing IP handsets or smartphones
• Support
• Configuring the terminal settings
• Viewing the battery status
• Setting up tracking
• Advanced settings
98-140012-B 39
Chapter 4: Using the web interface
Introduction
The web interface is built into the terminal and is used for operating, setting up and configuring
the system.
You can access the web interface from a computer, tablet or smartphone with a standard
Internet browser.
Note Some parts of the web interface may not be accessible if the user permissions are
limited. For information on how to set up user permissions, see To set up user
permissions on page 65.
98-140012-B Introduction 40
Chapter 4: Using the web interface
When the web interface opens, the title bar shows the name of the product.
Name and icon of current page (on opening page: the name of the product) Icon bar
Contents
Breadcrumbs section
Icon bar
98-140012-B Introduction 41
Chapter 4: Using the web interface
The icon bars are always available at the top and bottom of the web interface. Some of the
icons are permanent while others are temporary.
Icon Explanation
Battery level
Battery charging
No battery. Running on external power.
An event is active.
Click the icon to see a list of active events.
Note that this icon will remain in the icon bar as long as the
event is still active.
• To access status and settings, tap or click the relevant icon in the icon bar or select
to access the Control panel. The status or settings are displayed in the contents section.
• To see your current location and to move back through the Control Panel
menu, use the breadcrumbs just below the icon bar.
• To scroll through longer pages, use the scroll bar or swipe.
• To refresh the current page, click the page’s icon in the top left corner.
98-140012-B Introduction 42
Chapter 4: Using the web interface
Note You may not have to enter a SIM PIN to access the terminal. This depends on
whether or not the use of a SIM PIN is enabled on your SIM card.
The administrator can enable and disable the use of a SIM PIN. For details, see To
enable or disable the use of a SIM PIN on page 64.
If a smartphone, tablet or computer is connected when you start up the terminal, you can
access the web interface and enter the SIM PIN here.
1. If the pointing process is not automatically started, select and select Start.
The signal strength is shown on the screen.
2. Turn and tilt the antenna slowly until you have obtained the highest possible signal
strength.
3. Click Accept.
The terminal will now try to register on the BGAN network.
Note The icons for starting and stopping connections are only displayed if the
terminal is ready and registered on the BGAN network. Otherwise you cannot start
data connections.
Note Once a Streaming connection is started, the connection will run until you stop it.
You will be charged for the time you are connected.
When a connection is active, the icon turns green and the tile for the active connection shows:
• IP address: The IP address that has been assigned by the service provider to this session.
• Transferred data: For Standard data, the tile shows the total amount of transmitted and
received data since the connection was established.
• Connection duration: For Streaming data, the tile shows the total time the connection has
been active.
• Bit rate: For Streaming connections, the tile shows the currently available bit rate.
• For the Streaming classes with a guaranteed bit rate, the tile shows the guaranteed bit
rate.
• For the Streaming classes with a dynamic bit rate (BGAN X-Stream and HDR), the tile
shows the currently available bit rate. Note, however, that the bit rate is adjusted
according to the traffic on the connection. It takes approximately 15 seconds for the bit
rate to be updated after traffic has started on the connection.
By default, the following connections are available:
Standard data Several users can share the data connection. This type
of connection is ideal for TCP/IP traffic such as e-mail,
file transfer, and Internet and intranet access.
The user pays for the amount of data sent and
received.
1. Click in the right side of the tile with the connection that you want to change.
2. Click the name of the connection.
4. Click Save.
Viewing status
If the window is large enough, it shows a status field at the bottom of the page or in the right
side of the page. If not, click to show the status page. Click again to return to the
previous page.
Call log
The Call log shows:
• Outgoing calls shows the start time, receiving end phone number, duration, type
(Standard voice or 3.1 kHz audio) and, if Call charges have been entered, estimated charge
of each outgoing call.
• Received calls shows the start time, calling phone number, duration and type (Standard
voice or 3.1 kHz audio) of each incoming call.
• Missed calls shows the start time, calling phone number and type (Standard voice or
3.1 kHz audio) of each incoming call that was not received.
If a call fails, the call log shows the cause of the error.
You can clear the Call log under Control Panel > Advanced > Clear logs (requires
Administrator password).
Data log
The Data log shows:
• Standard data shows bytes uploaded , bytes downloaded , date and time and
estimated charge of each Standard data session (if Call charges have been entered).
• Streaming data shows the duration and type (such as 64 kbps, 256 kbps), date and time
and estimated charge of each Standard data session (if Call charges have been entered).
You can clear the Data log under Control Panel > Advanced > Clear logs (requires
Administrator password).
Total counters
The total counters show:
• Call session totals shows the total duration (hh:mm:ss) for each call type since the log
was last cleared.
• Data session totals shows totals for each data connection type since the log was last
cleared. For Standard data the totals are shown as amount of data transferred (kB) and for
Streaming connections the totals are shown in duration (hh:mm:ss).
You can clear the Total counters under Control Panel > Advanced > Clear total
counters (requires Administrator password).
Note The LAN network settings entered in the User group settings page also apply for the
WLAN interface.
Note In some countries, the use of WLAN is not allowed. Before continuing, make sure
WLAN is allowed and licensed in the country where you intend to use it.
4. Select the Channel number used for communication on the WLAN interface.
5. Select Broadcast SSID to show your WLAN access point to other users.
If you clear the box, your WLAN access point is hidden.
7. Select the Security standard. You may select one of the following encryption standards:
• None (no encryption is applied)
• WEP-40/64
• WEP-104/128
• WPA-TKIP
• WPA2-AES (selected by default)
Port forwarding
Note Make the port forwarding configuration before starting the data session.
Port forwarding enables you to set up a server connected to the terminal while the terminal is
in Router mode. Without port forwarding it would not be possible to contact the server from
the Internet.
We recommend using a static public IP address for the terminal in order to provide easy access
to the terminal. To use the static IP address, it must be included in your subscription and you
must set the APN source to SIM default. For details, see User group settings (LAN and WLAN)
on page 52.
The following example shows how to allow Internet access to a mail server (smtp) connected
to the terminal.
The mail server in this example has the IP address 192.168.0.100.
4. Type in the Incoming port start and the Incoming port end.
This is the range of port numbers on the EXPLORER 710 for which incoming traffic to the
EXPLORER 710 will be forwarded.
5. Type in the Destination IP address, which in this example is the IP address of the mail
server: 192.168.0.100.
This is the IP address to which the incoming traffic is forwarded.
6. Type in the Destination port start and the Destination port end.
This is the range of port numbers, in this example on the mail server, to which the
incoming traffic will be forwarded.
7. Click Save.
When you have activated a data connection, you can now access the mail server from the
Internet, using the external IP address of the terminal. You can see the external IP address on
the Dashboard, in the tile with the data connection you have started.
2. At Internet connection mode, select Modem mode or Router mode. Router mode
is the default setting and is recommended for most purposes.
• Select Router mode if one or more computers are connected using the LAN or WLAN
interface, and the EXPLORER 710 should act as a router. When Router mode is selected,
the EXPLORER 710 uses the built-in NAT module for making the necessary address
translations.
• Select Modem mode if
only one computer is connected to the LAN or WLAN interface, and the EXPLORER 710
should act as a modem, or
more than one computer is connected to the LAN or WLAN interface using an external
router.
Note Do not connect more than one computer to the LAN or WLAN interface in
Modem mode, unless you have an external Router.
Note You are charged for the data transferred. You may want to disable automatic
updates in your LAN or WLAN device to avoid unnecessary charges.
• When you disable automatic activation, you can control the data connection manually
from the dashboard.
6. If your APN uses a password, type in the User name and Password provided from the
Airtime Provider.
7. Click Save.
4. Click Save.
4. Click Save.
Overview
This section describes how to manage smartphones and IP handsets connected to the
EXPLORER 710.
The terminal supports connection of up to 16 handsets through the LAN or WLAN interface.
Each handset must have a local number in the range 0501 to 0516 as well as a unique
password. For details, see the next section.
For details on SIP settings and how to connect your handset to the LAN or WLAN interface, see
To connect a phone using LAN or WLAN on page 31.
1. Connect your smartphone to the WLAN interface or your IP handset to the LAN#1 port of
the terminal.
for details, see To connect a phone using LAN or WLAN on page 31.
3. Click the tile for the handset number you want to manage.
8. In the smartphone or IP handset, enter the local number and the password you just
entered in the web interface. See the documentation for your handset for details.
Note The user name is also the local number for the handset.
The handset remains in the list after disconnecting. When the handset is connected again, it is
automatically recognized and ready for use, if enabled.
Support
To open the Support page, select (Control panel) > Support.
98-140012-B Support 56
Chapter 4: Using the web interface
To update software
To update the software in the EXPLORER 710, do as follows:
1. Download the new software or acquire the software from Cobham SATCOM and save it on
your computer.
5. Browse to the new software version and click Open. The software file has the extension
“.tiif”.
When the EXPLORER 710 has finished updating the software, you get a message that the
software installation was successful.
6. Click OK.
The EXPLORER 710 now reboots and starts up with the new software version.
You can check the software version under Control panel > Support > About.
If, for some reason, you cannot upload software using the web interface, you can also use the
USB interface. For details, see To upload software with USB on page 72.
98-140012-B Support 57
Chapter 4: Using the web interface
2. After receiving the reset code from your supplier, select Reset password from the
Support page.
3. Type in the reset code obtained from your supplier and click Reset.
About
The About page shows the software version of your EXPLORER 710 and legal information.
To access the page, select Support > About.
1. In the Terminal settings page, locate Power-up mode when using external power.
3. Click Save.
2. Select Audio assisted pointing if you want to use a pointing sound to assist your
pointing process.
3. Click Save.
Note It may take some minutes for the EXPLORER 710 to change the navigation system.
Note The estimated remaining usage time can vary significantly, depending on usage. The
remaining time will be shorter if the terminal is used a heavily (more interfaces in use
and more calls and data sessions active).
Setting up tracking
You can set up the EXPLORER 710 to report to a server at certain time intervals. To set up
tracking, do as follows:
3. At Tracking and HDR, select Share HDR connection or Disable HDR connection.
When tracking is enabled, you cannot use a full HDR or BGAN X-Stream connection, so you
must select one of these two options:
• Share HDR connection: When Tracking is enabled and a HDR connection is started,
the terminal will use part of the HDR bandwidth for tracking.
• Disable HDR connection: As long as Tracking is enabled, you cannot start a HDR
connection.
8. Click Save.
If you have disabled HDR in step 3., you can see the status of the tracking link in the status area
of the web interface. If the status area is not shown, click to see it.
Note You can set up whether or not you want to allow the tracking server to control these
settings. See Remote control of tracking on page 70.
Advanced settings
Administrator password
If the administrator password is disabled and you want to protect the advanced settings with a
password, do as follows:
5. Click Save.
To log in
1. Log in as administrator
5. Click Save.
At the next login the new password is required.
If you have not entered anything for 30 minutes under Advanced, you are logged out
automatically. To log out manually, click Logout admin in the Advanced page.
Call charges
Note Cobham SATCOM does not take responsibility for the correctness of the estimated
charges. This calculation is only a rough estimate of the charge, based on the tariff
entered by the user. Also, the Airtime Provider may have different methods of
measuring the airtime used.
If you know the tariff for your subscribed services, you can enter these tariffs in the web
interface and automatically calculate the estimated charges for your calls and data sessions. To
enter the call tariffs, do as follows:
4. Click Save.
The entered tariffs are used for estimating the charges for calls and data sessions. For
further information, see Call log on page 48.
Important All configuration will be lost and the EXPLORER 710 will return to the default
configuration.
2. Click OK.
The terminal will now reboot and start up with the factory settings.
2. Under Enable/Disable PIN select or clear the box next to Require PIN on startup.
• If you clear the box, you can access and use the terminal without entering a PIN
• If you select the box, you must enter a PIN on startup before you can make calls or data
sessions
3. If you selected Require PIN on startup, type in the PIN next to Current PIN.
4. Click Save.
The new PIN settings will take effect at next power on.
4. Click Save. The new PIN settings will take effect at next power on.
3. Click Save.
The settings without a check mark can only be viewed but not changed by the non-
administrator user.
Link monitoring
You can monitor the external IP connection of the EXPLORER 710 system using the link
monitoring feature. With this feature activated, the terminal will send out ping commands
(ICMP Echo Requests) to a server of your choice.
Note The data connection must be activated before link monitoring can start. See To start
and stop data connections on page 45.
3. At Ping interval (minutes) select the Interval in minutes between the ping commands.
Note Use a server that is reliable and that responds to ICMP Echo Requests.
6. Click Save.
When a data session is started with the Default network user group, the terminal will start
sending ping commands to the Primary IP address the number of times specified at Number of
retries. If no response is received, it will send the same number of ping commands to the
Secondary IP address, if available. If no response is received here, the terminal will reboot.
Data limits
You can set a limit for the use of data services with the EXPLORER 710 system.
Once the entered limit is reached, the connection is automatically stopped. This is recorded in
the data log. To continue using the data service you must start a new connection by clicking on
the desired connection on the Dashboard.
Note If you set a data limit for the Standard data connection, automatic activation of the
Standard data connections is disabled.
4. Select Enable.
Remote management
You can set up the terminal so that it can be controlled from a remote location.
To set up the terminal for remote management, select Advanced > Remote management
from the Control panel.
1. From the Remote management page, select Enable access to web server and/or
Enable access to AT commands.
2. Type in the Incoming port numbers to use for the web server and for AT commands.
The default port numbers are:
• web server: 80
• AT commands: 5454
3. Under Trusted IP addresses, click Add IP address and type in the IP address of the
device you want to give access to the terminal.
4. To add more IP addresses, click Add IP address again.
Note To be able to access the terminal you must have an active data connection.
After preparing the terminal and activating the connection you can access the terminal from
one of the trusted IP addresses, using the incoming port defined in the Incoming port field.
• For information on how to prepare the terminal for remote activation of a data
connection, see the next section Remote access with SMS.
• For information on how to access the terminal, see To access the terminal from a
remote location on page 29.
If Static IP is included in your airtime subscription, we recommend using this static public IP
address for the terminal in order to provide easy access to the terminal. To use the static IP
address, it must be included in your airtime subscription and you must set the APN source to
SIM default. For details, see User group settings (LAN and WLAN) on page 52.
Note The terminal must be logged on to the satellite services to receive and accept an SMS.
If the SMS is considered too old or sent before the terminal has been switched on and
has logged on, the SMS will be ignored.
1. From the Remote management page, select whether you want to Enable remote
activation of data sessions.
2. Select whether you want an SMS confirmation for your data activation SMS.
Important If you want to receive an SMS with the IP address of the terminal after
sending an activation SMS, you must select Send SMS confirmation.
3. Select Enable access to AT commands, if you want to enable the EXPLORER 710 to
receive AT commands via SMS for remote management.
4. Enter the password. It can be up to 32 characters long. The characters 0-9, a-z and A-Z are
allowed. The password is mandatory and must match the password in the SMS. See To
activate a data connection with an SMS on page 30.
5. Enter at least one trusted mobile number from which the terminal accepts an SMS. If no
numbers are entered the feature is disabled automatically. Use the wild card * to accept a
range of trusted numbers.
7. Click Save.
For information on how to send an activation SMS, see To activate a data connection with an
SMS on page 30.
3. Click Save.
The EXPLORER terminal will now accept commands from the specified tracking server, for
example to change reporting intervals or start/stop reporting.
2. Click OK.
This will clear the call log and the data log.
2. Click OK.
This will reset the counters under Control panel > Log > Total counters.
Getting support
Contact information
Should your Cobham SATCOM product fail, please contact your dealer or installer, or the
nearest Cobham SATCOM partner. You will find the partner details on
www.cobham.com/satcom where you also find the Cobham SATCOM Self Service Center web-
portal, which may help you solve the problem.
Your dealer, installer or Cobham SATCOM partner will assist you whether the need is user
training, technical support, arranging on-site repair or sending the product for repair.
Your dealer, installer or Cobham SATCOM partner will also take care of any warranty issue.
If the original shipping carton is not available, the following general instructions should be used
for repacking with commercially available material.
1. Wrap the defective unit in heavy paper or plastic. Attach a tag indicating the type of
service required, return address, part number and full serial number.
3. Protect the front- and rear panel with cardboard and insert a layer of shock-absorbing
material between all surfaces of the equipment and the sides of the container.
Software update
Do as follows:
1. Download the EXPLORER 710 software image from the Cobham SATCOM support server
to your computer.
2. Insert the USB memory stick into your computer and copy the EXPLORER 710 software
image file to the drive.
5. On the EXPLORER 710, check in the display that the USB interface is enabled.
6. Insert the USB memory stick with the new software into the EXPLORER 710 USB
connector on the front.
The EXPLORER 710 reads the software image from the USB memory stick and starts the
software update process. The Status LED flashes blue to indicate that the software update
process is ongoing. When the software upload is completed, the EXPLORER 710 reboots.
7. Wait for the status LED to become green to indicate the software update process is
completed.
Important The recovery software upload will reset your EXPLORER 710 configuration to
factory default!
1. Prepare the USB stick as described in To prepare the USB stick on page 72.
2. In the display keypad, hold down the "<" and ">" keys while powering on the EXPLORER 710.
The EXPLORER 710 powers up and the display shows: SAFE MODE.
3. Insert the USB memory stick with the new software into the EXPLORER 710 USB
connector on the front.
The EXPLORER 710 reads the software image from the USB memory stick and starts the
software update process. The Status LED flashes blue to indicate that the software update
process is ongoing. When the software upload is completed, the EXPLORER 710 reboots.
4. Wait for the status LED to become steady green to indicate the boot up is completed.
Maintenance
To recharge batteries
To recharge the battery, connect external power to the DC input of the EXPLORER 710 while
the battery is inserted. For details on how to apply external power, see DC input on page 14.
You may connect an extra, external EXPLORER 710 battery for extra capacity. When external
power is applied to the EXPLORER 710, both batteries are charged as follows:
One battery is charged to 80%. Then the other battery is charged to 80%, and finally they are
both charged the last bit up to 100%. This way both batteries are charged in the shortest
possible time.
The display and the web interface of the EXPLORER 710 show battery status such as which
battery is currently charging and the battery level.
98-140012-B Maintenance 74
Chapter 5: Maintenance and troubleshooting
1. Acquire an extra EXPLORER 710 battery with a dedicated EXPLORER 710 Hot Swap Cable
(part number 403720B-010).
3. When the inserted battery runs out of power, the EXPLORER 710 switches to the external
battery and continues normal operation.
Important Before removing the empty battery, click/select the battery symbol in the
web interface or the display and make sure that the EXPLORER 710 is
actually running on the external battery.
4. If you have a third charged battery ready, you can now take out the inserted battery and
replace it with the new one, without interrupting the operation of the EXPLORER 710.
98-140012-B Maintenance 75
Chapter 5: Maintenance and troubleshooting
Storage
Do not leave the battery inserted in the EXPLORER 710 during storage. If the battery is not to
be used for a longer period of time, do as follows:
2. Remove external power. Then use the EXPLORER 710 or leave it on until the display shows
a battery capacity of approximately 50%.
Important Switch off the EXPLORER 710 before removing the battery!
98-140012-B Maintenance 76
Chapter 5: Maintenance and troubleshooting
Troubleshooting
Troubleshooting guide
The EXPLORER 710 The battery needs recharging. Recharge the battery. Check the
cannot be switched on, battery indicator in the display.
or does not stay on
when powered by the The battery is not inserted Remove the battery and re-insert
battery. properly. it. Make sure the battery is
inserted properly and that the
latches are locked.
There is no light in the The EXPLORER 710 may be in Press and simultaneously on
power indicator nor in Stealth Mode (all lights and the display keypad. This will toggle
the display when the sounds are off). Stealth Mode on/off.
EXPLORER 710 is
switched on.
The EXPLORER 710 The Power button was not When you switch off the
cannot be switched off. held long enough. EXPLORER 710, hold the power
button until the light indicator
flashes rapidly yellow.
In rare cases, it may take up to 10
seconds to switch off the
EXPLORER 710.
Charging error The temperature is below 0°C Only charge the battery when the
or above 40°C. temperature is within the range
0°C to 40°C.
98-140012-B Troubleshooting 77
Chapter 5: Maintenance and troubleshooting
The display shows The SIM card is not present. Remove the battery and insert the
Insert SIM. SIM card in the SIM slot according
to the instructions in the section
To insert the SIM card on
page 11.
The SIM card is not inserted Remove the SIM card and re-
properly. insert it according to the
instructions in the section To
insert the SIM card on page 11.
The display shows The EXPLORER 710 is unable Make sure the view to the GPS
No GPS fix. to register on the network, satellites is not blocked.
because the GPS position is To obtain GPS fix, the
unknown. EXPLORER 710 should be placed
flat on an even surface pointing
straight upwards, with a clear view
to as much of the sky as possible.
When the EXPLORER 710 has
obtained GPS fix, you can point
the antenna towards the BGAN
satellite.
To see the GPS status, select in
the display.
98-140012-B Troubleshooting 78
Chapter 5: Maintenance and troubleshooting
The display shows The EXPLORER 710 cannot Check that your SIM card is valid
Not registered. register on the BGAN for communication on the BGAN
network. network.
Check your subscription with the
Airtime Provider.
The display shows The EXPLORER 710 is If you want to use the built-in web
External control currently controlled by an interface or the display, stop the
external application, e.g. external application and restart
LaunchPad or an AT the EXPLORER 710. Then open
command interface. your browser and access the web
interface.
The EXPLORER 710 There is no GPS signal, or the Check the GPS status in the
cannot obtain its signal is weak. display or the web interface.
position using GPS. If the EXPLORER 710 has not To help the EXPLORER 710 obtain
been used recently within the GPS fix, it should be placed flat on
same location, it can take up an even surface pointing straight
to 10 minutes to obtain the upwards, with a clear view to as
GPS position. much of the sky as possible.
When the EXPLORER 710 has
obtained GPS fix, you can point
the antenna towards the BGAN
satellite.
No signal or weak signal The view to the satellite is Make sure the EXPLORER 710 has
from the BGAN satellite. blocked. a clear view to the satellite. Be
aware that window glass may
reduce the signal level.
98-140012-B Troubleshooting 79
Chapter 5: Maintenance and troubleshooting
The web interface The browser is configured to For Microsoft Internet Explorer,
cannot be accessed. use a proxy server. select Tools > Internet Options
> Connections > LAN Settings
and uncheck Use a proxy server
for your LAN.
Incoming calls: The call type Make sure the call type used for
used for the call is not calls to the EXPLORER 710 is
selected in the web interface. selected in the web interface.
Access the web interface and
select Control panel > Phone.
Then select the call type for
incoming calls.
98-140012-B Troubleshooting 80
Chapter 5: Maintenance and troubleshooting
Incoming phone calls: The Make sure the call type used for
call type used for the call is calls to the EXPLORER 710 is
not selected in the web selected in the web interface.
interface. Access the web interface and
select Control panel > ISDN.
Then select the call type for
incoming calls.
A LAN connection The interface is off in the Enable the interface by selecting
cannot be established. EXPLORER 710. the LAN interface icon in the
display, or
by accessing the web interface
and selecting Control panel >
LAN > Enable.
The cable is not properly Connect the cable.
connected.
98-140012-B Troubleshooting 81
Chapter 5: Maintenance and troubleshooting
The USB (Host) The interface is off in the Enable the interface by selecting
interface does not work. EXPLORER 710. the USB interface icon in the
display, or
by accessing the web interface
and selecting Control panel >
USB > Enable.
98-140012-B Troubleshooting 82
Chapter 5: Maintenance and troubleshooting
Status signalling
Means of signalling
The EXPLORER 710 system provides two methods for signalling the status of the system.
• Status indicator next to the display keypad
• Messages shown in the display and in the web interface.
Status indicator
In the display of the EXPLORER 710 you can see status messages and events that are currently
active.
When a warning or error event is active, the display shows a warning symbol . Select it to
see a list of currently active events.
98-140012-B Troubleshooting 83
Chapter 5: Maintenance and troubleshooting
List of messages
The following list explains some of the messages that may show in the display of the
EXPLORER 710.
Warning: Ciphering is OFF The network has turned Do not transmit data that
ciphering off. requires ciphering.
Connection closed. Data or The data connection is closed Restart the connection e.g.
time limit exceeded. because a data limit defined from the Dashboard in the
in the web interface is web interface. See To start
exceeded. and stop data connections
The data limit may be set to on page 45.
avoid unintentional use of You can change the data
bandwidth, e.g. if you forget limits in the web interface
to close a connection after under Advanced > Data limits.
use.
Automatic activation failed. The terminal failed to Wait for the terminal to
Reconnecting... automatically activate a reconnect.
Standard data connection at
start-up, even though it was
configured to do so.
Connection lost. The data connection was lost. Restart the connection e.g.
from the Dashboard in the
web interface. See To start
and stop data connections
on page 45.
98-140012-B Troubleshooting 84
Chapter 5: Maintenance and troubleshooting
Not registered to the network The terminal is not registered You can only make a
on the satellite network. connection if the terminal is
registered on the satellite
network.
Make sure that:
• The SIM card is present.
• The PIN has been
entered (if used).
• The terminal is pointed.
See Getting Started on
page 8 for details.
98-140012-B Troubleshooting 85
Chapter 5: Maintenance and troubleshooting
Log files
Diagnostics report
When contacting Cobham SATCOM for support, please include a diagnostic report.
The diagnostic report contains information relevant for the service personnel during
troubleshooting.
To generate the diagnostic report, access the web interface and select Control panel >
Support > Diagnostics report. Then click Generate report.
Technical specifications A
General specifications
Item Specification
Operating temperature
Powered by external DC -25 to 55C
(no battery or fully
charged battery)
DC operated and 0 to 45C
charging the battery
Powered from battery -20 to 55C
(discharging)
Storage temperature
Without battery -40 to 85C
With battery 1 year at -20 to 25C
3 months at -20 to 45C
1 month at -20 to 60C
Water & Dust
Transceiver IP52
Antenna IP66
98-140012-B 87
Appendix A: Technical specifications
Battery specifications
Item Specification
Interfaces specifications
Power input
Connector pin-out
This drawing shows the pin-out for the DC Power connector.
*1'
Specifications
Item Specification
AC/DC adapter
Item Specification
AC input range 100 to 240 VAC, 1.5 A, 47 to 63 Hz
DC output 19 VDC, 65 W
Phone interface
Connector pin-out
5-&RQQHFWRU
Pin Function
1 NC
2 Tip
3 Ring
)HPDOH 5HFHSWDFOH 4 NC
Specifications
Item Specification
ISDN interface
Connector pin-out
1 NC
2 NC
3 Rx+
4 Tx+
5 Tx-
Female (Receptacle)
6 Rx-
7 NC
8 NC
Specifications
Item Specification
Connector pin-out
1 Rx+
2 Rx-
3 Tx+
4 NC
5 NC
Female (Receptacle)
6 Tx-
7 NC
8 NC
Specifications
Item Specification
Number of connectors 2
Connector type RJ-45, female, Auto cross-over MDI/MDI-X
(IEEE 802.3 10/100BaseT)
Standard ISO/IEC 8877:1992 and
IEEE 802.3 1998 Edition
Specifications
Item Specification
Connector pin-out
Pin Function
1 VBUS
2 D-
3 D+
4 GND
Specifications
Item Specification
Specifications
Item Specification
Specifications
Item Specification
Frequencies
Inmarsat I-4
Transmit 1626,5 MHz - 1660,5 MHz
Receive 1525 MHz - 1559 MHz
Inmarsat Alphasat Extended L-band (XL)a:
Transmit 1626,5 MHz - 1660,5 MHz and 1668 MHz - 1675 MHz
Receive 1518 MHz - 1559 MHz
GNSS GPS and Glonass
Satellite coverage
The EXPLORER 710 uses the Inmarsat I-4 satellites and the Alphasat satellite for satellite
communication. The drawings below show the coverage areas for these satellites.
80°
70°
60°
50°
40°
30°
20°
10°
0°
10°
20°
30°
40°
50°
60°
70°
80°
90°
180° 160° 140° 120° 100° 80° 60° 40° 20° 0° 20° 40° 60° 80° 100° 120° 140° 160° 180°
Conformity B
CE (R&TTE)
The EXPLORER 710 is CE certified (R&TTE directive) as stated in “Declaration of Conformity
with R&TTE Directive”, enclosed in electronic copy on the next page. The WLAN interface is CE
certified through the manufacturer of the WLAN card.
Use of WLAN:
The WLAN interface requires that the user enters the current country of operation. See
Configuring the WLAN interface on page 50.
For use in the EU, the following restrictions apply:
• France: Outdoor use must be limited to 10 mW EIRP within the frequency band 2454 MHz
to 2483.5 MHz.
• Italy: Outdoor use outside own premises require general authorization.
IC
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this device may not cause interference, and (2) this
device must accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne
doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d'en compromettre le
fonctionnement.
This Class [B] digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe [B] est conforme à la norme NMB-003 du Canada.
WLAN:
Under Industry Canada regulations, this radio transmitter may only operate using an antenna
of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To
reduce potential radio interference to other users, the antenna type and its gain should be so
chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary
for successful communication.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut
fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour
l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique
à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la
puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à
l'établissement d'une communication satisfaisante.
98-140012-B 96
Appendix B: Conformity
This radio transmitter (certification number 3913A-APPN551 (Single)) has been approved by
Industry Canada to operate with the antenna types listed below with the maximum permissible
gain and required antenna impedance for each antenna type indicated. Antenna types not
included in this list, having a gain greater than the maximum gain indicated for that type, are
strictly prohibited for use with this device.
Le présent émetteur radio (no. de certification 3913A-APPN551 (Single)) a été approuvé par
Industrie Canada pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un
gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types
d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué,
sont strictement interdits pour l'exploitation de l'émetteur.
WLAN antenna types approved for use with the EXPLORER 710:
WLAN antenna for EXPLORER 710, part number 88-139591. Max gain: 1.89 dBi / 50 Ohm.
FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Part 15.21
Changes or modifications not expressly approved by the party responsible for
compliancecould void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected
• Consult the dealer or an experienced radio/TV technician for help
98-140012-B 97
Glossary
Glossary
BGAN Broadband Global Area Network. A satellite network based on geostationary satellites,
delivering broadband data and telephony to virtually any part of the earth, with full UMTS
(3G) compatibility. BGAN enables users to access e-mail, corporate networks and the
Internet, transfer files and make telephone calls.
DHCP Dynamic Host Configuration Protocol. A protocol for assigning dynamic IP addresses to
devices on a network. With dynamic addressing, a device can have a different IP address
every time it connects to the network.
DNS Domain Name System. A system translating server names (URLs) to server addresses.
GNSS Global Navigation Satellite System. A navigation satellite system using the GPS, GLONASS,
Galileo or Beidou system.
HDR High Data Rate. A BGAN service supporting a portfolio of four new streaming rates,
including asymmetric services.
98-140012-B 99
Glossary
ICMP Internet Control Message Protocol. An Internet protocol mostly used for diagnostics.
IP Internet Protocol. The method or protocol by which data is sent from one computer to
another on the Internet.
LAN Local Area Network. A computer network covering a small physical area, like a home,
office, school or airport. The defining characteristics of LANs, in contrast to wide-area
networks (WANs), include their usually higher data-transfer rates, smaller geographic area,
and lack of a need for leased telecommunication lines.
NAT Network Address Translation. An Internet standard that enables a local-area network to
use one set of IP addresses for internal traffic and a second set of addresses for external
traffic. A NAT module makes all necessary address translations.
PBX Private Branch Exchange, telephone exchange that serves a particular business or office.
PIN Personal Identification Number. A code number used to provide access to a system that
has restricted access.
PoE Power over Ethernet. A standard for combining power supply with transmission of data
over the Ethernet. The source unit "injects" power into the Ethernet cable and the power
is "picked up" at the connected device.
PPPoE Point-to-Point Protocol over Ethernet. A network protocol for encapsulating Point-to-
Point Protocol (PPP) frames inside Ethernet frames. By using PPPoE, users can virtually
"dial" from one machine to another over an Ethernet network, establish a point to point
connection between them and then securely transport data packets over the connection.
98-140012-B 100
Glossary
RF Radio Frequency. Electromagnetic wave frequencies between about 3 kHz and about
300 GHz including the frequencies used for communications signals (radio, television,
cell-phone and satellite transmissions) or radar signals.
SIM Subscriber Identity Module. The SIM provides secure storing of the key identifying a
mobile phone service subscriber but also subscription information, preferences and
storage of text messages.
SIP Session Initiation Protocol. An application-layer control (signaling) protocol for creating,
modifying, and terminating sessions with one or more participants. Used e.g. for Internet
telephony.
USB Universal Serial Bus. A specification to establish communication between devices and a
host controller (usually personal computers). USB is intended to replace many varieties of
serial and parallel ports. USB can connect computer peripherals such as mice, keyboards,
digital cameras, printers, personal media players, flash drives, and external hard drives.
UTC Coordinated Universal Time. The International Atomic Time (TAI) with leap seconds
added at irregular intervals to compensate for the Earth’s slowing rotation. Leap seconds
are used to allow UTC to closely track UT1, which is mean solar time at the Royal
Observatory, Greenwich.
98-140012-B 101
Index
Index
Numerics B
2-wire battery
connect a phone, 33 capacity display accuracy, 75
connector, 90 charge, 74
hot-swap, 75
insert, 11
A remove, 12
short description, 7
AC⁄DC adapter specifications, 89 brightness in display, 37
access
remote, 29
access to settings C
limit in web interface, 65
access using AT commands, 29 call charges
admin password estimating in web interface, 64
change, 63 call log, 48
disable, 63 calls
enable, 62 make, 35
log in, 63 missed, received, outgoing, 48
log out, 64 total usage, 48
reset, 58 CE compliance, 96
advanced settings, 62 charge
Alphasat EXPLORER 710 batteries, 74
coverage area, 95 smartphone or tablet, 37
frequencies, 94 charges for calls
analogue phone estimating, 64
connect, 33 clear logs, 70
antenna configuration
connect, 14 IP handsets and smartphones, 55
connector, 94 ISDN, 54
detach, 9 LAN, 49
fixed, 20 phone interface, 53
point, 16 USB, 54
separate from transceiver, 9 WLAN, 50
short description, 6 conformity, 96
APN connect a phone
set up, 53 Phone interface, 33
AT commands WLAN or LAN, 31
access with IP, 29 connect interfaces
remote access with IP, 30 LAN, 25
automatic activation, 53 WLAN, 24
automatic shut down connect power, 14
connection, 66 connection
automatic shut down, 66
98-140012-B 102
Index
98-140012-B 103
Index
IP header compression, 53 P
ISDN
configure, 54 password
connect phone or modem, 34 change, 63
connector, 91 disable, 63
items included, 8 enable, 62
log in, 63
log out, 64
L reset, 58
smartphone or IP handset, 55
LAN permissions
automatic activation of, 53 setting for users, 65
configure, 49 phone
connect a computer, 25 configure, 53
connect an IP handset, 32 connect to LAN or WLAN, 31
connectors, 92 connect to Phone interface, 33
user group settings, 52 connector, 90
latch for transport, 9 SIP settings, 31
LED on front panel, 83 phone call, 35
light indicator, 83 PIN
limit changing, 65
allowed kB, 66 enabling or disabling, 64
allowed time, 66 enter in display, 15
data, 66 enter in web interface, 43
limiting user access, 65 ping command from the terminal, 66
link monitoring, 66 point the antenna, 16
log in as administrator, 63 point the antenna again, 18
log of data connections, 48 pointing process
log out as administrator, 64 restarting, 18
logs, clear, 70 port forwarding, 51
power
connecting, 14
M Power connector, 89
power supply
maximum for data, 66
AC⁄DC adapter, 89
menu in display, 6
modem mode, 52
monitoring the external IP connection, 66
R
recovery
N software, 73
remote management
navigation
access using AT commands, 30
display, 5
access using web interface, 30
navigation in web interface, 42
activation with SMS, 30
network settings
preparation, 29
LAN and WLAN, 52
set up in web interface, 67
remove battery, 12
remove SIM card, 12
repoint the antenna, 18
98-140012-B 104
Index
U
S update software, 57
safety summary, iii USB, 72
separate antenna form transceiver, 9 usage
settings calls and data, 48
in web interface, 47 USB
limit access, 65 charge smartphone or tablet, 37
restore, 64 configure, 54
SIM card connector, 93
insert, 11 update software, 72
remove, 12 user group settings
short description, 7 LAN and WLAN, 52
SIP settings, 31 user name
smartphone smartphone or IP handset, 55
charge via USB, 37 user permissions
connect for calls, 31 setting up in web interface, 65
manage in EXPLORER 710, 55
SIP settings, 31
user name and password, 55 W
SMS
activate data connection, 30 warning messages, 37, 57
software warranty, 71
recovery, 73 web interface
update with USB, 72 accessing, 40
update with web interface, 57 definition, 40
view current version, 38 navigating, 42
Standard data what’s in the delivery, 8
definition, 24 WLAN
start data connection, 26 automatic activation of, 53
Status configure, 50
view in web interface, 47 connect to, 24
storage, 76 user group settings, 52
Streaming data
definition, 24
T
tablet
charge via USB, 37
total usage, 48
tracking the terminal, 38
setup in web interface, 60
98-140012-B 105
98-140012-
www.cobham.com/satcom