0% found this document useful (0 votes)
19 views1 page

Fourth Floor Ac Ventilation Layout A: A-C-2.2A-C-4.1 A-C-2.2A-C-4.1

The document appears to be a detailed layout or schematic for a facility, including various rooms, equipment specifications, and airflow details. It includes information on dimensions, capacities, and types of air distribution systems for different areas such as offices, storage, and conference rooms. The document is technical in nature and likely intended for engineering or architectural purposes.

Uploaded by

Arnulfo Balaba
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
19 views1 page

Fourth Floor Ac Ventilation Layout A: A-C-2.2A-C-4.1 A-C-2.2A-C-4.1

The document appears to be a detailed layout or schematic for a facility, including various rooms, equipment specifications, and airflow details. It includes information on dimensions, capacities, and types of air distribution systems for different areas such as offices, storage, and conference rooms. The document is technical in nature and likely intended for engineering or architectural purposes.

Uploaded by

Arnulfo Balaba
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

25 26 27 28 29 31 32 33 34

60.00

4.00 8.00 12.00 6.00 12.00 8.00 4.00 6.00

C D
A-C-2.2A-C-4.1 A-C-2.2A-C-4.1

200x200 EAG 1000x300 EAG 1000x300 SAG


(typ. to all ERV-2000) (typ. to all ERV-2000)
@ 388 cfm)

200x200 EAG
1 200x200 EAG 3 300x300 EAG/SAG
(typ. to 3
@ 392 cfm)
2 300x300 EAG/SAG
(typ. to 3
@ 392 cfm)
(typ. to all
@ 200 cfm)
@ 200 cfm)

G IHOMP POWER DISTRIBUTION/ UPS


AREA
FCU-15.3
300x200 RAD
IHOMP STOCK ROOM/
REPAIR ROOM
CONFERENCE ROOM
FCU-14.2
350x200 SAD
350x
200 SAD 350x200 EAD ERV-f

GLASS BOARD
2.5HP 2HP 2000

GLASS BOARD
350x350 EAD RISER

MIXING
1.00 1.00 ERV-f

BOX

150x150 EAD
300x200 SAD 250x200 SAD 300x200 SAD 250x200 SAD
WI - 1.87 WI - 2.805 2000 250x TO ROOF
FCU-14.3 FCU-14.4 FCU-14.5 200 SAD
FCU-14.6 (@ 2100 CFM)
350x300 EAD RISER 1200x200 SAG IHOMP .8HP 4HP 4HP 4HP
(I.T.)
TO ROOFDECK (TYP. TO 2) 200x200SERVER
FAG STORAGE

350x200 EAD
UNITS AUDITORIUM
STAGE
(@ 1800 CFM/UG-1) @ 588 cfm) FCU-14.1 350x200 SAD
9.00

650x400 EAD RISER

WI - 1.87
1000x400 RAG 3.2HP AUDITORIUM TO ROOF
SYSTEM
400x300 EAD RISER (TYP. TO 2) 350x200 EAD 300x200 EAD 250x200 EAD 300x200 EAD 250x200 EAD (@ 4500 CFM/LG)
PANTRY STORAGE
TO ROOFDECK AREA
(@ 2100 CFM/LG-1)

WI - 2.805
IHOMP OFFICE
WI - 1.87 WI - 2.805 WI - 1.87 WI - 1.87 WI - 1.87 WI - 1.87 2- PIPE RISER

600x300 RAD
TO ROOF

600x300 RAD
UP UP
350x250 EAD 550x350 EAD 600x350 EAD 700x400 EAD 850x400 EAD 850x450 EAD 1000x450 EAD DECK (ACCU)
FD
200x200 EAD 150x150 EAD 150x100

E 1.00
WI - 2.805 WI - 2.805 WI - 1.87 WI - 1.87 WI - 1.87 WI - 1.87 WI - 2.805 WI - 1.87

1.00
DOFFING
150x100
DECON-
TAMINATION
ROOM

FCU-15.2
MIXING
250x200 EAD RISER BOX
ROOM
150x
5HP 800x300 EAG AUXILLARY

1000x500 EAD
TO ROOFDECK @ 1,066 cfm ROOM 150 EAD
(@ 800 CFM) (typ. to 11)
350x350 EAD

CANS PAPERPLASTICS
6.00

FCU-15.1 350x
MIXING

ELECTRICAL OPEN BELOW


BOX

5HP ROOM 300 EAD 1300x600 EAD RISER


6- PIPE RISER 200x200 EAG
TO ROOF 200x200 EAG (typ. to all
REFER TO ELEVATOR
DECK (ACCU) (typ. to all @ 150 cfm) SERVICE

DISPOSAL AREA
SCHEMATIC DIAGRAM

GENERAL
LOBBY

WASTE
GARBAGE
PUBLIC @ 100 cfm) INFECTIOUS
LOBBY WASHING
AREA

D WI - 1.87 WI - 1.87 WI - 2.805 WI - 1.87 WI - 1.87 WI - 2.805 WI - 2.805 WI - 2.805WI - 1.87

300x300 EAD
33.00

350x250 EAD 550x350 EAD 600x350 EAD 700x400 EAD 850x400 EADCORRIDOR
NON-STERILE 850x450 EAD 1000x450 EAD 1000x500 EAD

300x300 EAG
WI - 2.805 WI - 2.805 WI- 0.917 WI - 1.87 WI - 2.805 WI- 0.917 WI- 0.917 WI- 0.917 WI- 0.917 WI- 0.917 WI- 0.917 WI- 0.917

1.220
DINING FCU-13.1 LOCKER LOCKER
(typ. to all
3- PIPE RISER 150x100 EAD FCU-f1
@ 300 cfm)
AREA 5HP ROOM ROOM TRAYS AND TROLLEYS
TO ROOF (F) (M) WASHING AREA
1.3HP
NUTRITIONIST

150x150 EAD 150x100 EAD


SPECIAL DIET /

150x150 EAD
DECK (ACCU) OFFICE POTS
9.00

FORMULA

WI - 1.87
AND PANS

4
ROOM
200x200 EAG WASHING

1.80
600x400 EAD RISER
1.80

FCU-13.2 150x100 SAD AREA NON-INFECTIOUS


(typ. to all

WI - 1.87
SUPPLY RECEIVING

150x150 EAD

150x150 EAD

300x250 EAD
TO ROOFDECK 1HP CLEAN TROLLEY WASHING AREA
200x200 EAD

FCU-13.3 STORAGE @ 200 cfm) AREA


(@ 4000 CFM/LG-1)

150x150 SAD
1HP FOR DELIVERY WI- 0.917 WI- 0.917 WI- 0.917 WI- 0.917

WI - 2.805 WI - 2.805 2000x800 EAG


1.220
400x400 EAD RISER STAFF WORK AREA 200x200 EAG/
400x400 EAD 300x250 EAD 200x150 EAD 200x150 150x100 EAD JANITOR'S
TO ROOFDECK SAG (typ. to all 150x150 EAD 200x150 EAD 200x200 EAD 250x200 EAD 300x200 EAD CLOSET W/
400x350 EAD STERILE CORRIDOR MOP SINK

150x100 EAD
(@ 2500 CFM) 150x100 SAD @ 100 cfm) 1400x450 KED 3.7 SQM

C 5- PIPE RISER
200x150 EAD
300x200 EAD

300x200 EAD

150x150 EAG/ TO ROOF


FCU-13.4

WI - 2.805
PUBLIC PUBLIC 150x100 EAD SAG (typ. to all MEAT DECK (ACCU)
400x400 EAD RISER TOI. (M) TOI. (F) 2HP 350x
250 FAD

200x200 EAD
200x200 SAD
TO ROOFDECK FD UP @ 50 cfm) 600x
300 FAD
350x
250 FAD COLD STORAGE DRY STORAGE
UP
FCU-13.5 500x400 EAD RISER
(@ 2700 CFM) 1400x450 KED RISER
.8HP 500x 800x 1000x 1200x 1400x
1400x
450 KED
TO ROOF

HALAL
450 KED COOKING
450 KED AREA450 KED 450 MEAT
STAFF 450 KED (@ 3500 CFM)
400x

150x100 EAD
TOI. 400 KED
1000x250 FAG @ 960

HALAL
350x
350x300 EAD RISER
150x150 EAD

250 FAD 600x


PANTRY CFM (typ. to 10) 300 FAD 350x300 KED @ 1200

300 FAD
TO ROOFDECK 1400x800 SAG @
250x200 SAD

700x
250x200 EAD
150x100 EAD DIETITIAN'S CFM (typ. to 10)
STAFF VEGETABLES
(@ 1800 CFM/UG) 7,500 CFM
9.00

800x TOI. OFFICE FCU-16.3 800x


WI - 2.805

400 8HP 400


400x400 EAD RISER FOOD ASSEMBLY AREA
150 SAD

2
250x200 EAD

FCU-16.4
150x
250x200 EAD

800x
TO ROOFDECK

600
VEGETABLES
150x150 SAD 350x 350x250 FAD 600x500 SAD 8HP
(@ 2700 CFM) PB 250 FAD PB
GLASS BOARD

1.22
CONFERENCE ERV-f BAKERY HALAL KITCHEN 600x500 SAD
6500 6500

WASHING
600x400 EAD RISER ROOM 1000 MIXING
800x600
TO ROOFDECK KSB BOX BAKING

800x 9600 FCU-16.1 800x

WI - 2.805
FCU-16.2

500 FAD
(@ 4000 CFM/UG) UTENSILS

WI- 0.917
150x100 EAD FCU-13.6

800x
250x200 EAD 8HP
400 (typ. to all)
2HP HALAL PREPARATION
8HP FOOD PREPARATION
STORAGE 400

B
1400x800 SAG
1400x800 SAG
200x200 EAG 1400x700 FAG w/ 1000x1000x700
MIXING BOX 1400x700 FAG w/
(typ. to all @ 150 cfm) INSECTS SCREEN INSECTS SCREEN
300x300 SAG/EAG 600x200 600x200
150x100 EAD (typ. to all)
(typ. to all @ 300 cfm) SAG EAG
200x200 EAG
(typ. to all @ 100 cfm)

AS-BUILT PLAN BUILDING C


A FOURTH FLOOR AC VENTILATION LAYOUT
ME-C 4.4 SCALE 1:150 M

PREPARED PROFESSIONAL MECHANICAL ENGINEER PROJECT TITLE SHEET CONTENTS OWNERS CHECKED CONCURRED APPROVED SHEET NO.

MODERNIZATION OF GOVERNOR
CELESTINO GALLARES
AS-BUILT PLAN
BUILDING C
FOURTH FLOOR
ME-C 4.4
PRC No. : MULTI-SPECIALTY MEDICAL CENTER
ENGR. JAYSON P. LADORES PTR No. : DATE : AC VENTILATION
AC TUMANG/JJ and J CONSTRUCTION LAYOUT OSCAR R. RUIVIVAR, UAP DONNA VIDA BALIOLA, UAP LAURENCE ELLIOT R. TIROL, MD, FPCP CAD by:
AND GENERAL SUPPLY J.V. TIN : PLACE : PRINCIPAL PROJECT MANAGER, ADMINISTRATIVE OFFICER V MEDICAL CENTER CHIEF I, GCGMSMC CHECKED by:
LOCATION : MALAYO SUR, CORTES, BOHOL OSCAR R. RUIVIVAR AND ASSOCIATES HEAD, ENGINEERING & FACILITIES MANAGEMENT, GCGMSMC
ADDRESS : DATE:

You might also like