RAU–HC01–B1
ALL 11 PAGES AT EDITION 07
DATE–NO:
Official Copy
RAU–HC01–B1
CONTENTS
All rights reserved. Passing on and copying of this
document, use and communication of its contents
1.RACK DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
not permitted without written authorization.
1.1.Functional content . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.2.Power figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.RACK LAYOUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.BLOCK DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1AA 00014 0004 (9007) A4 IDSS (9206)
ED
2
LIST OF ILLUSTRATIONS
ED
3
Application rules Official Copy
1. RACK DESCRIPTION
All values are given in watts and should be taken as reference; detailed calculations, based upon latest
power figures, should be made for each application.
ED 07
– In case of single testbus use plug 211 27908 AAGA in positions 01BA16 from SAU 02 , 03 , 06 and
07 and in positions 33BA16 from SAU 02 and 03.
There are maximum 36 C–wires sense (CWS) and 36 C–wires drive (CWD) available per line
module, (128 lines) or a max. of 72 circuits per module can be equipped with C–wire drive/sense only.
If this cabling is required, the ’C’–wires have to be connected first on 4 input/output positions
(capacity 2x9 points) by means of strap wire (211 00293 1105 slate, section 0,25) under
responsibility of the CAE engineer (strap wires will be placed during the installation of the exchange).
From each of this input/output positions a cable 211 27999 XXXA is through connected to the MDF.
For detailed information about the position of the ’C’–wires on the line boards and the reserved I/O
positions see the added figure. The exact positions of the ’C’–wires on the I/O positions have to be
defined by the CAE engineer, taking into consideration that ’C’–wires for ’sense’ and for ’drive’ must
not be placed on two neighbouring horizontal terminals. (pairing of ’C’–wires for ’sense’ and for ’drive’
1AA 00014 0004 (9007) A4 IDSS (9206)
is forbidden).
For using of more ’C’–wires there must be make connections, directly to the line PBA’s with a special
cable.
ED 07
ED
Figure 1
07
Application rules
Cabling of ”c”–wires
Official Copy
3. RACK LAYOUT
– BPA partnumbers
– Module numbering (refer to block diagram of fig.3 and 4)
– Power branch (A or B) of convertors
– Convertor to module power feeding (continuous lines)
– Minimum equipment
4. BLOCK DIAGRAM
ED 07
ED
Figure 2
07
Application rules
Rack layout
Official Copy
ED
Figure 3
07
Application rules
Block diagram I
Official Copy
ED
Figure 4
07
Application rules
Block diagram II
Official Copy
ED
UNIT:
AUTHOR:
07
EXTENSION:
Application rules
DEPARTMENT:
INFORMATION ABOUT THIS DOCUMENT
BELL
SH444
M. VAN DORST
Official Copy
211CNB950222–06