OFFER FOR 4 TPH M/s.
CRIMSUN
3-PASS WITH ORGANICS PVT LTD,
EXTRNAL
REVERSING C-9,10&C-11 SIPCOT
MEMBRANE INDUSTRIAL
PANNEL
HYBRIDBOILER COMPLEX,
FUEL-IMPORTED CUDDALORE-607 005.
COAL-BUBBLING
BED
S.F.NO-17/11-D, KUMARAMANGALAM INDUSTRIAL
AREA,MATHUR,TAMILNADU,INDIA.PIN-622515.
TEL: +91 431 6994999; e-mail :
[email protected];
web : www.matrixboilers.com
Regd. Office & Works: S.F.No. 17/11D, Kumaramangalam Industrial Area, Mathur -622515. Pudukkottai Dist.
Tel: 0431 – 250884, e-mail: [email protected], Website: www.matrixboilers.com
6TPH HYBRIDBOILER, SRI LANKA
Regd. Office & Works: S.F.No. 17/11D, Kumaramangalam Industrial Area, Mathur -622515. Pudukkottai Dist.
Tel: 0431 – 250884, e-mail: [email protected], Website: www.matrixboilers.com
3TPH HYBRID BOILER
Regd. Office & Works: S.F.No. 17/11D, Kumaramangalam Industrial Area, Mathur -622515. Pudukkottai Dist.
Tel: 0431 – 250884, e-mail: [email protected], Website: www.matrixboilers.com
4TPH HYBRID BOILER
Regd. Office & Works: S.F.No. 17/11D, Kumaramangalam Industrial Area, Mathur -622515. Pudukkottai Dist.
Tel: 0431 – 250884, e-mail: [email protected], Website: www.matrixboilers.com
Ref : MB/OFF/HIF/2021-22/149
Date : JULY 05, 2021
M/S. CRIMSUN ORGANICS PVT LTD,
C-9,10&C-11 SIPCOT INDUSTRIAL COMPLEX,
KUDIKADU VILLAGE,
CUDDALORE-607 005
Dear Sir,
Sub: Offer for the Supply of 4 Ton/hr @17.5KG/CN2 ,Hybrid with 3-pass Bubbling Bed
Boiler(Coal) – Reg.
We thankfully acknowledge the receipt of your valuable enquiry. We express our sincere thanks
for the keen interest you have shown on our range of products. As desired by you, we enclose
herewith our offer for the supply of 4Ton/hr External reversing membrane panel with boiler.
We trust that our offer will be in line with your requirement. In case, if you come across with any
clarifications, please feel free to contact us.
Thanking you and assuring you of our best attention and services at all times.
Yours faithfully
for MATRIX BOILERS.,
A.SEKAR
DIRECTOR
Regd. Office & Works: S.F.No. 17/11D, Kumaramangalam Industrial Area, Mathur -622515. Pudukkottai Dist.
Tel: 0431 – 250884, e-mail: [email protected], Website: www.matrixboilers.com
INDEX TO ANNEXURE
ANNEXURE – 1 TECHNICAL SPECIFICATION
ANNEXURE – 2 STANDARD SCOPE OF SUPPLY
ANNEXURE – 3 EXCLUSION FOR STANDARD SUPPLY
ANNEXURE – 4 BATTERY LIMITS FOR SUPPLY
ANNEXURE – 5 PERFORMANCE CRITERIA
ANNEXURE – 6 MAKE OF SUB-VENDORS ITEMS
ANNEXURE – 7 PRICE AND COMMERCIAL TERMS
ANNEXURE – 8 WARRANTY CLAUSES
Regd. Office & Works: S.F.No. 17/11D, Kumaramangalam Industrial Area, Mathur -622515. Pudukkottai Dist.
Tel: 0431 – 250884, e-mail: [email protected], Website: www.matrixboilers.com
ANNEXURE – 1
TECHNICAL SPECIFICATIONS
1.1 Design Fabrication : IBR 1950 with latest Amendments
Inspection & Testing Code
1.2 Type of Boiler : HMT External reversing membrane panel with
3-Pass Boiler ,Bubbling Bed.-Coal
1. 3 Model : HTH-40
1. 4 Evaporation Capacity : 4000 kg/hr (F&A 100 Deg.C)
1.5 Design Pressure : 17.5 Kg/cm² (g) / 150 PSI (g)
1.6 Maximum Working
Pressure : 17.5 Kg / sq cm (g)
1.7 Fuel
: Imported coal of GCV 4500 kcal / kg-Auto feeding
Solid Fuel: Briquette( Manual Feeding)
1.8 Mode of Combustion : Balanced Draught - Over Bed
1.9 Heating surface area : 150M2/ 16005SQ.FT
1.20 Connected Electrical load
FD Fan : 1 No x 40 HP
Regd. Office & Works: S.F.No. 17/11D, Kumaramangalam Industrial Area, Mathur -622515. Pudukkottai Dist.
Tel: 0431 – 250884, e-mail: [email protected], Website: www.matrixboilers.com
ID Fan : 1No x 40HP
PA Fan : 1No x 10HP
Pocket Feeder : 1No x 3HP
Ash Feeder : 1No x .5HP
Pump (2 No) : 2 Nos x10 HP
1.9.1 PRESSURE PARTS SPECIFICATION:
A. SHELL
Shell ID : 2700mm
Shell length with Water Wall : 3800mm
Shell thickness : 20mm
Shell End Plate Thick : 22mm
Plate Specification : SA515/516 Gr70
Make : Sail/Jindal
Regd. Office & Works: S.F.No. 17/11D, Kumaramangalam Industrial Area, Mathur -622515. Pudukkottai Dist.
Tel: 0431 – 250884, e-mail: [email protected], Website: www.matrixboilers.com
B. FURNACE
Furnace OD : 1500mm
Furnace Length : 3000mm
Furnace thickness : 20mm
Plate Specification : SA515/516 Gr70
Make : Sail/Jindal
C. TUBES
II PASS : OD63.5x3.66x 3000L -134NOS.
III PASS : OD63.5x3.66x 3000L -78NOS
Tube Specification : BS3059 Gr320 ERW PART-I
DESCRIPTION FLOW HEAD RPM HP TEMP Type of
m3/s mmwc Drive
FD Fan 2.95 500 2880 40 400C Direct
ID Fan 3.5 475 1440 40 200℃ Couple Drive
PA Fan .6 650 2880 10 400C Direct
Regd. Office & Works: S.F.No. 17/11D, Kumaramangalam Industrial Area, Mathur -622515. Pudukkottai Dist.
Tel: 0431 – 250884, e-mail: [email protected], Website: www.matrixboilers.com
1.9.2 Feed Water Pump:
Type : Vertical Multistage centrifugal
Flow : 6.3 m³ / hr
Head : 225 mwc
Speed : 2880 rpm
Temperature : 1050C
Rating : 10HP
Quantity : 2 Nos.
Note: Id Fan considered Following pressure drop.
1. MDC
2. Water Pre Heater(Optional)
3. Bag filter(Exclusion)
ANNEXURE – 2
STANDARD SCOPE OF SUPPLY
2.1 Horizontal Multi-tubular Shell type 3-pass external reversing membrane panel boiler with
necessary Mounting, fittings, saddle to mount the boiler, with distributor plate and
SS-310GrAir Nozzles, which is suitable for multi fuel like Coal& Briquette.
2.2 Feed line from feed pump to Boiler – 2 Nos.
2.3 Ladder with handrails and platform.
2.4 Lining of boiler.
2.5 Blow down valve with blow down line from Boiler to blow down valve (max. 3 mt)
2.6 Air duct from FD fan to boiler.
2.7 PA duct from Pocket feeder to boiler furnace-1no.
2.8 6” Mixing Nozzle-1no and Fuel pipe line bunker to furnace.
2.9. Refractory lining in furnace and Man way doors
Accessories:
Regd. Office & Works: S.F.No. 17/11D, Kumaramangalam Industrial Area, Mathur -622515. Pudukkottai Dist.
Tel: 0431 – 250884, e-mail: [email protected], Website: www.matrixboilers.com
2.10 Feed pump with motors – 2 Nos
2.11 FD Fan with Motor – 1 No
2.12. ID Fan With motor-1No
2.13. Pocket feeder with motor-1no
Electrical:
2. 14. Automatic water level controller -1 No
2. 15.Control panel Board – 1No
2. 16.Pocket Feeder with Gear motor – 1 No
2. 17.Pressure Switch – 1 No
2.18.VFD for FD , ID, and Pocket feed Motors
2.19.Thermocouple- 3nos.
2.20.Draught gauge for FD and ID
Safety Interlock:
The following Safety & Interlock are provided in our boiler System.
When steam pressure is high, the boiler will be tripped.
Boiler will tripped in the event of very low water level
UNSAFE CONDITION INSTRUMENTS ACTION
Alarm & FD,
Very Low Water Level in the Boiler. Level Controller
PA&feeder Trip
Alarm & FD,
Steam Pressure high Pressure Switch
PA&feeder Trip
High Water Level Level Controller Pump OFF
Low Water Level Level Controller Pump ON
Regd. Office & Works: S.F.No. 17/11D, Kumaramangalam Industrial Area, Mathur -622515. Pudukkottai Dist.
Tel: 0431 – 250884, e-mail: [email protected], Website: www.matrixboilers.com
ANNEXURE -3
EXCLUSION FOR STANDARD SUPPLY
3. 1 Guy rope supported side chimney, flue gas duct connecting from boiler to Chimney.
3. 2 Transport and Transit Insurance.
3. 3 Bag filter and water Pre heater, Coal Bunker ,coal handling plant.
Piping-Steam, water, Blow down, drain, Exhaust-Its insulation and support.
3. 4 Water piping from source to water softener, Water softener outlet to Feed water service tank
and all interconnecting pipings up to feed water pump suction flange.
3. 5 Unloading of Boiler, Erection ,Insulation of boiler, IBR approval for errectiom of Boiler and
steam pipe line and IBR inspection at site
3. 6 All Electrical works within boiler house including supply of power cable,
Control cables, earthing material & laying.
3.7 All Civil works including Grouting Foundation of equipments for Boiler & Accessories.
3. 8 Any other items which are not mentioned specifically in Supplier’s scope.
Regd. Office & Works: S.F.No. 17/11D, Kumaramangalam Industrial Area, Mathur -622515. Pudukkottai Dist.
Tel: 0431 – 250884, e-mail: [email protected], Website: www.matrixboilers.com
ANNEXURE – 4
BATTERY LIMITS FOR SUPPLY
4. 1 Steam : Up to outlet flange – Main steam Stop Valve, Air Vent & Safety Valve.
4. 2 Water : From suction flange of feed water pump.
Inlet & Outlet of Water softener.
4. 3 Drain : Up to WLG drain cock and AWLC Drain.
4. 4 Blow Down : Up to outlet of Blow down Valve.
4. 5 Fuel : Inlet of vibratory feeder.
4. 6 Flue gas : Up to outlet of Boiler shell.
4. 7 Air : From inlet flange of FD Fan.
4. 8 Electrical : Inlet & outlet terminal connection point in control panel
(Control panel only in MATRIX scope)
Regd. Office & Works: S.F.No. 17/11D, Kumaramangalam Industrial Area, Mathur -622515. Pudukkottai Dist.
Tel: 0431 – 250884, e-mail: [email protected], Website: www.matrixboilers.com
ANNEXURE - 5
PERFORMANCE CRITERIA
WATER:
The performance parameters of the boiler under this offer are based on filtered and
treated water of the following quality being available.
SPEIFICATION OF FEED WATER TO BOILER:
Residual hardness as CaCo3 ppm : 5 Max.
PH Value : 8.5 to 9.5
Oil content ppm : Nil
Oxygen (O2) ppm : Nil
Free Co2 ppm : Nil
Bound Co2 ppm : 5 Max
Total dissolved solids ppm : 400 Max.
SPECIFICATION OF WATER IN BOILER:
Total hardness as CaCo3 ppm : 5 Max.
Alkalinity ppm : 15 to 20 % TDS
PH value : 10.5 to 11
Sodium sulphite (Na2 So3) ppm : 50 Max.
(Undissolved)
P2 O5 ppm : 15 to 30
Oxygen (O2) ppm : Nil
Total dissolved solids ppm : Less than 3500
Regd. Office & Works: S.F.No. 17/11D, Kumaramangalam Industrial Area, Mathur -622515. Pudukkottai Dist.
Tel: 0431 – 250884, e-mail: [email protected], Website: www.matrixboilers.com
ANNEXURE – 6
MAKE OF SUB-VENDORS ITEMS
6.1 Blow Down Valve : RUSHAS
6.2 FD Fan : MATRIX
6.3 Motors : SIEMENS
6.4 Feed Pumps + Motor : GRUNDFOS
6.5 Safety Valve : DARLING MUESCO
6.6 Main Steam Stop Valve : RUSHAS
6.7 AWLC : MALHOTHRA
6.8 Pressure Gauges : M/s. FORBES MARSHALL
6.9 Water Level Gauge : RUSHAS
6.10 Disc Type NRV : EXPERT
6.11 Vertical check valve : RUSHAS
6.12 Fusible plug : RUSHAS
6.13 Drain valve : RUSHAS
6.14 Pressure switch : INDFOS
6.15 Control Panel : MATRIX
6.16 All Isolation Valves(IBR) : RUSHAS
Regd. Office & Works: S.F.No. 17/11D, Kumaramangalam Industrial Area, Mathur -622515. Pudukkottai Dist.
Tel: 0431 – 250884, e-mail: [email protected], Website: www.matrixboilers.com
ANNEXURE – 7
PRICE AND COMMERCIAL TERMS
8.1 FINAL PRICE:
8.1.1 For the supply of items as per
Annexure – 2 : RS.51,85,000/-
(Scope of Supply vide Sl.No.2.1 to 2 .18)
8.1.2 Supply of Mechanical Dust Collector : RS.3,55,000/-
with ash feeder.
8.2 OPTIONAL SUPPLY:
8.2.1 Supply of Vertical Single Pass : Rs.4,50,000/-
Water pre Heater .
8.2.1 Supply of Flue Gas Ducting from Boiler : Rs.2,25,000/-
to Chimney thro WPH, MDC and ID Fan
Max.15mtrs.
8.2 COMMERCIAL TERMS:
8.2.1 Basis of price : Ex. Work, Mathur
8.2.2 Taxes & Duties : GST-18% Extra
.
8.2.4 Packing & Forwarding : 2%Extra
8.2.5 Teansport &Transit insurance : Buyer’s scope
8.2.6 Payment terms : 50% as Advance along with Purchase order.
Balance Payment before dispatch against our
Proforma Invoice
8.2.7 Delivery at our works (Trichy) : Within 70 days from the date of receipt of
clear purchase order along with Advance
8.2.8 Validity : Our offer is valid for 10 days from the date
of offered .
Regd. Office & Works: S.F.No. 17/11D, Kumaramangalam Industrial Area, Mathur -622515. Pudukkottai Dist.
Tel: 0431 – 250884, e-mail: [email protected], Website: www.matrixboilers.com
ANNEXURE – 8
WARRANTY CLAUSE
The boiler is warranted against malfunction arising out of faulty design, material and / or
workmanship for a period of 12 months from the date of commissioning or for a period of 15
Months from the date of despatch whichever is earlier. This clause will be applicable if and only if
SELLER'S recommendations on feed water, fuel parameters, electrical input etc., are strictly
adhered-to by the BUYER and Boiler is operated as per instructions given in the O & M Manual
supplied.
Bought out components are guaranteed by SELLER only to the extent of the guarantees given to
SELLER by their VENDOR. Electrical components such as heaters, motors, contactors etc rubber
components and instruments such as pressure gauges, thermometers and bearings etc. and normal
wear & tear of components are however not covered under this warranty.
Any parts/components that are required to be replaced during the warranty period shall be supplied
free of cost within the guaranteed period. However, the Transport payable
For such components shall be reimbursed by the purchaser.
for MATRIX BOILERS.,
A.SEKAR
DIRECTOR
Regd. Office & Works: S.F.No. 17/11D, Kumaramangalam Industrial Area, Mathur -622515. Pudukkottai Dist.
Tel: 0431 – 250884, e-mail: [email protected], Website: www.matrixboilers.com