GOLDI Module Datasheet 550
GOLDI Module Datasheet 550
High Efficiency
21.30% IP68 Junction Box
Excellent module conversion
High waterproof level
efficiency of up to 21.30%
Low-light Performance
Advanced glass and cell surface textured design
ensure excellent performance in low-light environment
Short circuit current - Isc(A) 14.76 14.83 14.91 14.99 15.07 15.14
# Additional power gain from rear side compared to power of front side at STC depends on mounting
structure (height, tilt angle etc.) and reflectivity of ground.
Ø7*Ø10 mm
Bi-Faciality Factor : 70 ± 5 %
Mounting hole
4 Nos.
1 5 10 15 20 25 30
##
• Quantity of modules/container may get changed without prior notice.
• For handling & installation instructions, refer to Goldi's installation manual available on the company website
• Before placing an order, confirm your requirements with our sales representative 1800 833 5511
• The electrical data provided is for reference purposes only
• PV modules needs to be disposed as per goverment regulations, after it’s life cycle [email protected]
• Refer to Goldi's warranty document for terms and conditions
• Due to constant product modifications, Goldi reserves the right to amend the above specifications without prior notice goldisolar.com
• Images in the datasheet are for representation purpose only
GS10-T144-GF
(575 Wp - 580 Wp)
High Efficiency ↑ ↑
10-30% Additional Power Generation
22.45%
Excellent module conversion ↑ ↑
More than 10-30% additional power gain
efficiency of up to 22.45% comparing with the regular modules.
PACKAGING CONFIGURATION##
Number of Modules per Pallet 36
Ø4 Earthing
No of pallet 20 4 Nos.
No of module, 40ft HC container 720
Ø3*10
Drain hole
8 Nos.
1095
IV CURVE PV CURVE 1134
Back view
700 Side view
Incident Irrad. = 1000 W/m2
16 Incident Irrad. = 800 W/m2
Incident Irrad. = 1000 W/m
2 600 Incident Irrad. = 600 W/m2
14 Incident Irrad. = 400 W/m2
Incident Irrad. = 200 W/m2 Ø7*Ø10mm Ø9*Ø14mm 9
500 Cells temp. = 25°C mounting hole
12 Incident Irrad. = 800 W/m2 mounting hole
Current (A)
400 7
30
10
30
300
14
Incident Irrad. = 400 W/m2
6 10
200 15 30
4 Incident Irrad. = 200 W/m2 a : a' b : b'
100
2
0
“Tolerance for Length & width is of ±2mm & unspecified dimensions tolerance are according to ISO 2768-1, class m.”
0
10 20 30 40 50 60 0 10 20 30 40 50 60
0
Voltage(V) Voltage(V)
PRODUCT CERTIFICATIONS
LINEAR GRAPH
Standard Module Linear Performance Warranty
99.0% Goldi N-type Bifacial Double Glass Module
97.0% Linear Performance Warranty
89.4%
87.4 % MANAGEMENT SYSTEM CERTIFICATIONS
87.4% 1.00%
1st-year Degradation
TDS-GS10T144GF-V 1
ISO 9001,
80.0% 0.40% ISO 14001,
ISO 45001
Annual Degradation
0
1 5 10 15 20 25 30
Years
##
• Quantity of modules/container may get changed without prior notice.
• For handling & installation instructions, refer to Goldi's installation manual available on the company website
• Before placing an order, confirm your requirements with our sales representative 1800 833 5511
• The electrical data provided is for reference purposes only
• PV modules needs to be disposed as per goverment regulations, after it’s life cycle [email protected]
• Refer to Goldi's warranty document for terms and conditions
• Due to constant product modifications, Goldi reserves the right to amend the above specifications without prior notice goldisolar.com
• Images in the datasheet are for representation purpose only