MEDION 340 – 310
From serial number:
934 00610
932 02724
Technical Systems
Electric System
Electric system MEDION TIC
TIC MEDION Electric system
Layout of electric circuit
diagrams
Following the circuit diagram layout, all electric circuits are shown in
individual circuit diagrams. Some explanations are given below to illustrate
the layout.
Numbering of circuit diagrams
Me-e-01a - The respective numbering can be found on the corresponding cover
sheet and in the footer.
- Depending on the machine no., the components fitted and the country
specification, there may be several individual circuit diagrams 01b,
01c, etc. for a given function.
Potentials
- Main power supply (battery)
- Ignition switch power supply (switched)
- Relay-controlled power supply
- Earth
- Housing earth (external)
Connections
- The description provided inside the circle (e.g. „S52”) defines the
connection.
- Numbers next to the circle (e.g. „4”) describe the continuation of the
cabling in accordance with the circuit diagram numbering. This circuit
diagram numbering can be taken among others from the footer.
Example: Many electric circuits depend on the road travel activation
switch S52 (see circuit diagram 04a). Therefore there are
functions on circuit diagrams 20, 24 and 30 which can only be
activated when S52 is closed.
Designations
- Connectors (e.g. „MFAgn”, pin 3 and 5) .
Each chapter lists the respective connectors and their pin assignment
in the individual connection tables.
- Modules (e.g. „A12 - Speed monitor“)
The arrows identify the functional inputs and outputs according to the
assignment table provided in chapter ZE.
Electric system MEDION TIC
6-m-19 - Position of components according to component grid coordinates
A 1 ... Z 99 - Component designation according to CLAAS standards catalogue
A - Terminal / Module
B - Sensor
E - Lighting
F - Fuse
G - Voltage Source
H - Signalling Device / Lamp
K - Relay
M - Electric Motor
P - Gauge
R - Potentiometer / Resistor
S - Switches - Cab Operation
T - Switches - Terminal Operation
U - Switches - External Operation
V - Electronic Component
W - Antenna
X - Connector
Y - Solenoid coil
Z - Actual Value Function Switch
Connections list
from to 1 mm
2
Colour - List of connections within the central terminal compartment, stating
HKB-17 K77/86 0.75 br cross-section (mm²) and colour of cables connected to the machine.
KBA-10 Y 25 0.5 bk
WSA- 5 S 54 0.5 bl-wh
rd - red
bk - black
br - brown
wh - white
bl - blue
gr - grey
ye - yellow
gn - green
pi - pink
or - orange
vi - violet
TIC MEDION Electric system
CONTENTS
Central terminal compartment .......................................................................................ZE-2
Pin assignment in modules............................................................................................ZE-6
Automatic air conditioner module A6:.....................................................................ZE-7
Cab fan speed controller module A7: .....................................................................ZE-7
Contour module (CAC) A8: Spare part no. 011 015.x ............................................ZE-8
Contour module A8: Spare part no. 011 026.x .......................................................ZE-8
AUTOPILOT module A9:........................................................................................ZE-9
Speed monitor module A12:...................................................................................ZE-9
Electronic engine control module A15:.................................................................ZE-10
Engine adaptation module (ADM) A17:................................................................ZE-10
Yield meter module A21: ......................................................................................ZE-11
Deflector adjustment module A26: .......................................................................ZE-11
Multifunction handle module A52: ........................................................................ZE-12
Overview of fuses:................................................................................................ZE-13
1a Main power supply, Diesel engine electric starting motor ...................................... 1a-2
2a Starting the diesel engine, diesel engine speed adjustment .................................. 2a-2
3a Diesel engine cut-off system .................................................................................. 3a-2
4a Activation of road travel, master valve ................................................................... 4a-2
5a Fieldwork computer................................................................................................ 5a-2
7a Threshing mechanism circuit.................................................................................. 7a-2
8a Threshing drum variable-speed drive..................................................................... 8a-2
10a Fan variable-speed drive...................................................................................... 10a-2
Electric system MEDION TIC
12a Deflector adjustment, performance monitor.......................................................... 12a-2
14a Swinging the grain tank unloading tube ................................................................ 14a-2
15a Grain tank unloading ............................................................................................ 15a-2
17a Front attachment drive.......................................................................................... 17a-2
19a Reel variable-speed drive ..................................................................................... 19a-2
19b Rake-up - Speed adjustment, hydraulic oil temperature monitoring .................... 19b-2
20a Raise/lower front attachment, transverse control.................................................. 20a-2
21a Reel adjustment.................................................................................................... 21a-2
23a Folding the cutterbar............................................................................................. 23a-2
24a AUTOCONTOUR (CAC)....................................................................................... 24a-2
24b CONTOUR ........................................................................................................... 24b-2
25a Speed monitoring ................................................................................................. 25a-2
26a Machine monitoring .............................................................................................. 26a-2
27a Yield meter ........................................................................................................... 27a-2
28a AUTOPILOT .......................................................................................................... 28a2
29a All-wheel drive ...................................................................................................... 29a-2
30a Grain tank full indicator / warning beacon............................................................. 30a-2
TIC MEDION Electric system
31a Turn flasher system.............................................................................................. 31a-2
32a Main light circuit, position light.............................................................................. 32a-2
33a Dipped headlights, dipped headlights changeover............................................... 33a-2
34a Work lights ........................................................................................................... 34a-2
35a Grain tank, sieve pan and returns lighting, reversing horn, brake light................. 35a-2
36a Interior lights, instrument lighting.......................................................................... 36a-2
37a Windscreen wiper................................................................................................. 37a-2
38a Compressor-type air conditioner, cab fan ............................................................ 38a-2
38b Automatic air conditioner...................................................................................... 38b-2
39a Air-suspended seat compressor........................................................................... 39a-2
40a Additional sockets ................................................................................................ 40a-2
50a Electric mirror adjustment .................................................................................... 50a-2
Component grid ...............................................................................................................R-2
Index..........................................................................................................................index-2
Electric system MEDION TIC
Central terminal compartment
Electric system MEDION TIC
Central terminal compartment
ZE-2 Me-e-ZE 09/06
TIC MEDION Electric system
Key to diagram: a Fuse block a .................................................. ZE (Central terminal
compartment)
a1 Left-hand work lights fuse.............................. 34
a2 Reel adjustment fuse ..................................... 4, 14, 15, 17, 20, 21,
24
a3 Cab outside work lights fuse.......................... 34
a4 not used
a5 Lights main circuit fuse ................................. 32
a6 CAC / Cab electric system fuse..................... 24, 36
a7 Lights main circuit fuse .................................. 32
a8 Cab fan fuse .................................................. 38
a9 Function information unit fuse ....................... 12, 24, 26, 30
a10 Lights main circuit fuse .................................. 32
a11 Windscreen wiper fuse .................................. 37
a12 Road travel enable fuse................................. 4
a13 Lights main circuit fuse .................................. 32
a14 Engine control unit fuse ................................. 2
a15 Drive fuse....................................................... 7, 15, 17, 19
a16 Work lights fuse ............................................. 34
a17 Front attachment circuits / 8, 20, 21, 23,
reel adjustment fuse ...................................... 40
a18 Lighting, sieve pan, grain tank and
returns fuse.................................................... 35
A8 AUTOCONTOUR module (CAC)................... 20, 24
A9 AUTOPILOT module (ATP) ........................... 28
A12 Speed monitor module (DZW)....................... 25
A17 Engine adaptation module (ADM) ................. 1,2
A52 Multi-function handle module......................... 14, 15, 17, 20, 21, 24
B Fuse block b .................................................. ZE
b1 Right-hand dipped headlights fuse ................ 33
b2 Vehicle information unit / Indicator fuse......... 1, 3, 5, 26, 28,
31
b3 Warning beacon fuse..................................... 30
b4 Left-hand dipped headlights fuse .................. 33
b5 Indicator system fuse..................................... 31
b6 Instrument lighting fuse.................................. 26, 29, 33,
35, 36
b7 Work lights fuse ............................................. 34
b8 Work lights fuse ............................................. 34
b9 Horn fuse ....................................................... 35, 39
b10 Threshing mechanism fuse ........................... 7, 10, 12, 28, 40
b11 Fan variable-speed drive fuse ....................... 10
b12 Relay K59 control fuse................................... 3, 38
b13 Speed monitor fuse........................................ 10, 25
b14 Reel variable-speed drive.............................. 19
b15 Alternator release fuse................................... 3
b16 Additional socket fuse.................................... 40
b17 Cooling unit, air conditioner fuse ................... 38
b18 Fieldwork computer / Yield meter fuse .......... 5, 27
C1 Front attachment reverse fuse....................... ZE, 17
DO Master valve diode PCB ................................ 4
DI Diode PCB ..................................................... 2b, 3, 24,
25, 26, 30
DM Daimler-Chrysler diagnosis plug.................... ZE, 2
F3 Engine fuse block .......................................... ZE, 2
09/06 Me-e-ZE ZE-3
Electric system MEDION TIC
Key to diagram: K11 Start relay ............................................................... 1
K49 Dipped headlights relay.......................................... 33
K50 Dipped headlights relay.......................................... 33
K52 Work lights far relay................................................ 34
K53 Right-hand cab work light relay.............................. 34
K54 Left-hand cab work light relay ................................ 34
K55 Contour circuit relay ............................................... 24
K56 Warning beacon relay ............................................ 30
K57 Transducer ............................................................. 31
K59 Engine oil pressure relay........................................ 3
K60 Road travel release relay ....................................... 4,
K61 Alternator release relay .......................................... 3
K62 Front attachment reverse relay .............................. 17a
K63 Threshing mechanism relay ................................... 7
K66 Tail light relay ......................................................... 34
K68 Cooling system relay .............................................. 38
K69 Reel speed adjustment relay.................................. 19
K70 Reel speed adjustment relay.................................. 19
K71 Fan speed relay...................................................... 10
K72 Fan speed relay...................................................... 10
K75 Additional power supply relay ................................ 38
K76 Grain tank full sensor relay .................................... 30
K77 Warning buzzer relay ............................................. 3
K78 Front attachment circuit relay................................. 17
K79 Front attachment circuit relay................................. 17
K86 Deflector adjustment relay ..................................... 12
S35 Engine speed adjustment switch............................ 2
ZE-4 Me-e-ZE 09/06
Pin assignment in modules
Electric system MEDION TIC
Pin assignment in modules
ZE-6 Me-e-ZE 06/07
TIC MEDION Electric system
Automatic air conditioner module A6:
Pin Function Component Measuring Direction Circuit
variable diagram no.
X1/1 Terminal 61 G2 12 V Input 38b
X1/2 Power a8 / 30A 12 V Input 38b
X1/5 Instrument lighting E 35 12 V Output 36a
X1/6 Earth -31 0V Input 38b
X2/1 Icing protection Z 74 12 V Output 38b
X2/2 Heater solenoid coil Y109 12 V (PWM) Output 38b
X2/3 PWM fan M7 12 V (PWM) Output 38b
X2/9 Power a8 / 30A 12V Input 38b
X3/1 Inside temperature B86 -20° - 97070 Ω --- 38b
X3/2 Inside temperature B86 -10° - 55330 Ω --- 38b
X3/3 Blow-out temperature B87 0° - 32650 Ω --- 38b
X3/4 Blow-out temperature B87 10° - 19900 Ω --- 38b
X3/5 Outside temperature B88 20° - 12490 Ω --- 38b
X3/6 Outside temperature B88 30° - 8057 Ω --- 38b
40° - 5327 Ω
50° - 3603 Ω
60° - 2488 Ω
Cab fan speed controller module A7:
Pin Function Component Measuring Direction Circuit
variable diagram no.
1 Earth -31 0V Output 38b
2 not used --- --- --- ---
3 not used --- --- --- ---
4 Power M7 0-12 V Output 38b
5 Earth M7 0V Input 38b
6 not used --- --- --- ---
7 PWM fan A6 12 V (PWM) Input 38b
8 Power A7 12 V Input 38b
06/07 Me-e-ZE ZE-7
Electric system MEDION TIC
Contour module (CAC) A8: Spare part no. 011 015.x
Pin Function Component Measuring Direction Circuit
variable diagram no.
1 Cutterbar release S52 12 V Input 24a
2 Pre-set cutting height control ON S13 Earth Input 24a
3 Cutterbar right-hand transverse control Y67 Earth Output 20a
4 not used
5 AUTOCONTOUR indicator (LED) H37 Earth Output 24a
6 Pre-set cutting height control indicator (LED) H38 Earth Output 24a
7 not used
8 Earth 31 Earth Input 24a
9 not used
10 Cutterbar left-hand transverse control Y68 Earth Output 20a
11 Lower cutterbar Y87 Earth Output 20a
12 Raise cutterbar Y85 Earth Output 20a
13 CAC main switch S11 Earth Input 24a
14 12 V power supply (terminal 15) S52 12 V Input 4a
15 CAC ON S12 Earth Input 24a
16 Earth 31 Earth Input 19b, 24a
17 Earth 31 Earth Input 24a
18 12 V power a6 12 V Input 24a
19 Pre-set cutting height control actual value R8 0.25-4.75 V Input 24a
20 5 V reference output R1, R2, 5V Output 24a
R23, R24
21 Right-hand sensing band actual value R2, B4 0.25-4.75 V Input 24a
22 Left-hand sensing band actual value R1, B3 0.25-4.75 V Input 24a
23 Spring actual value R22 0.25-4.75 V Input 24a
24 CAC set value R23 0.25-4.75 V Input 24a
25 Pre-set cutting height control set value R24 0.25-4.75 V Input 24a
Contour module A8: Spare part no. 011 026.x
Pin Function Component Measuring Direction Circuit
variable diagram no.
1 Cutterbar release S52 12 V Input 24a
2 Pre-set cutting height control ON S13 Earth Input 24a, 24b
3 Cutterbar right-hand transverse control Y67 Earth Output 20a
4 not used - - - -
5 AUTOCONTOUR indicator (LED) H37 Earth Output 24a
6 Pre-set cutting height control indicator (LED) H38 Earth Output 24a
7 not used - - - -
8 Earth 31 Earth Input 24a
9 not used - - - -
10 Cutterbar left-hand transverse control Y68 Earth Output 20a
11 Lower cutterbar Y87 Earth Output 20a
12 Raise cutterbar Y85 Earth Output 20a
13 CAC main switch S11 Earth Input 24a
14 12 V power supply (terminal 15) S52 12 V Input 4a
15 not used - - - -
16 Earth 31 Earth Input 19b, 24a
17 Earth 31 Earth Input 24a
18 12 V power a6 12 V Input 24a
19 Pre-set cutting height control actual value R8 0.25-4.75 V Input 24a
20 5 V reference output R1, R2, 5V Output 24a
R23, R24
21 Right-hand sensing band actual value R2, B4 0.25-4.75 V Input 24a
22 Left-hand sensing band actual value R1, B3 0.25-4.75 V Input 24a
23 Spring actual value R22 0.25-4.75 V Input 24a
24 CAC target value R23 0.25-4.75 V Input 24a
25 Pre-set cutting height control set value R24 0.25-4.75 V Input 24a
ZE-8 Me-e-ZE 06/07
TIC MEDION Electric system
AUTOPILOT module A9:
Pin Function Component Measuring Direction Circuit
variable diagram no.
1 AUTOPILOT main switch S10 12 V / 7.5 A Input 28a
2 AUTOPILOT main switch S10 12 V / 7.5 A Input 28a
3 Steering left Y10 0V Output 28a
4 Steering left Y10 0V Output 28a
5 Seat contact signal Z5 Earth Input 28a
6 ATP (Autopilot) control H2 0V Output 28a
7 not used - - - -
8 Earth 31 Earth Input 28a
9 Earth 31 Earth Input 28a
10 Solenoid coils + Y9, Y10 12 V Output 28a
11 Solenoid coils + Y9, Y10 12 V Output 28a
12 Steering right Y9 0V Output 28a
13 Steering right Y9 0V Output 28a
14 AUTOPILOT wheel position B6 0.25-4.75 V Input 28a
15 AUTOPILOT ON S9 Earth Input 28a
16 ATP signal OFF B83 Earth Input 28a
17 AUTOPILOT wheel position GND B6 0V Output 28a
18 AUTOPILOT wheel position POWER SUPPLY B6 5V Output 28a
19 Connection with pin 20 - - - 28a
20 Connection with pin 19 - - - 28a
21 ATP. pushbutton B7, B8 5V Output 28a
22 ATP. pushbutton B7, B8 0V Output 28a
23 AUTOPILOT centralizing switch R3 0.25-4.75 V Input 28a
24 AUTOPILOT left pushbutton B7 0.25-4.75 V Input 28a
25 AUTOPILOT right pushbutton B8 0.25-4.75 V Input 28a
Speed monitor module A12:
Pin Function Component Measuring Direction Circuit
variable diagram no.
1 Straw walker warning light H35 12 V Output 25a
2 Straw walker speed signal B26 1.0-1.2 kΩ Input 25a
3 Earth -31 0V Input 25a
4 Returns elevator warning light H36 12 V Output 25a
5 Returns warning light B10 1.0-1.2 kΩ Input 5a
6 --- --- --- --- ---
7 --- --- --- --- ---
8 Power input 12 V / 3 A b13/3A 12 V Input 25a
9 Grain elevator warning light H32 12 V Output 25a
10 Feeder housing speed signal B12 1.0-1.2 kΩ Input 25a
11 Chopper in working position Z59 0V Input 25a
12 Feeder housing warning light H27 12 V Output 25a
13 Straw chopper warning light H34 12 V Output 25a
14 Pulse relay warning message H4 --- Output 25a
15 --- --- --- --- ---
16 Returns speed signal B29 1.0-1.2 kΩ Input 25a
17 --- --- --- --- ---
18 --- --- --- --- ---
19 --- --- --- --- ---
20 --- --- --- --- ---
21 Grain elevator speed signal B21 1.0-1.2 kΩ Input 25a
22 --- --- --- --- ---
23 --- --- --- --- ---
24 --- --- --- --- ---
25 Straw chopper speed signal B28 1.0-1.2 kΩ Input 25a
06/07 Me-e-ZE ZE-9
Electric system MEDION TIC
Electronic engine control module A15:
Pin Function Component Measuring Direction Circuit
variable diagram no.
X1/1 CAN-H --- --- --- 2
X1/2 CAN-L --- --- --- 2
X1/3 HF-GND --- --- --- 2
X1/4 HF-GND --- --- --- 2
X1/5 12 V power (terminal 30) --- 12 V Input 2
X1/6 12 V power (terminal 30) --- 12 V Input 2
X1/8 Electric starting motor power --- 12 V Input 2
(terminal 50)
X1/9 Earth --- 0V Input 2
X1/11 Earth --- 0V Input 2
X1/13 Diagnosis DM --- --- 2
X1/15 12 V power (terminal 15) --- 12 V Input 1
Engine adaptation module (ADM) A17:
Pin Function Component Measuring Direction Circuit
variable diagram no.
1/01 12 V input power (terminal 30) --- 12 V Input 2
1/02 12 V input power (terminal 15) --- 12 V Input 2
1/03 Earth --- 0V Input 2
1/06 Cooling water temperature warning H24 0V Output 3
2/05 Earth --- 0V Input 2
2/06 Engine speed signal (max.) S35 0V Input 2
2/10 Engine speed signal (3rd gear) Z41 0V Input 2
3/13 CAN-LH (J 1939) --- --- --- 2
3/14 CAN-HF-GND (J 1939) --- --- --- 2
3/15 CAN-LL (J 1939) --- --- --- 2
4/02 Diagnosis --- --- --- 2
4/03 Diesel engine oil pressure signal H50 12 V Output
light
4/04 Cooling water temperature display P8 --- Output 3
ZE-10 Me-e-ZE 06/07
TIC MEDION Electric system
Yield meter module A21:
Pin Function Component Measuring Direction Circuit
variable diagram no.
1 --- --- --- --- ---
2 Earth (GND) 31 Earth Input 27a
3 CAN high - - - 27a
4 --- --- --- --- ---
5 Yield signal B59 1.2 V / >2.5 V Input 27a
6 --- --- --- --- ---
7 --- --- --- --- ---
8 --- --- --- --- ---
9 --- --- --- --- ---
10 Inclination – actual value signal B62 1.2-4.8 V Input 27a
11 Humidity + signal B61 --- Input 27a
12 --- --- --- --- ---
13 --- --- --- --- ---
14 --- --- --- --- ---
15 Power b18 / 7.5 A 12 V / 1 A Input 27a
16 CAN low - - - 27a
17 --- --- --- --- ---
18 --- --- --- --- ---
19 --- --- --- --- ---
20 Power b18 / 7.5 A 12 V / 10 A Input 27a
21 Humidity - signal B61 --- Input 27a
22 Humidity temperature signal B61 --- Input 27a
23 Inclination – actual value signal B62 1.2-4.8 V Input 27a
24 --- --- --- --- ---
25 --- --- --- --- ---
Deflector adjustment module A26:
Pin Function Component Measuring Direction Circuit
variable diagram no.
1 Power I M22 12 V Output 12a
2 Power I M22 12 V Output 12a
3 Power II M22 12 V Output 12a
4 Power II M22 12 V Output 12a
5 Power K86 12 V / 15 A Input 12a
6 Power K86 12 V / 15 A Input 12a
7 --- --- --- --- ---
8 Earth (GND) 31 Earth Input 12a
9 Earth (GND) 31 Earth Input 12a
10 Linear motor – actual value signal R28 0.25-4.75 V Input 12a
11 Linear motor – set value signal R29 0.25-4.75 V Input 12a
12 Linear motor reference voltage R28, R29 5V Output 12a
13 Linear motor reference output R28, R29 Earth Output 12a
14 --- --- --- --- ---
15 --- --- --- --- ---
16 --- --- --- --- ---
17 --- --- --- --- ---
18 --- --- --- --- ---
19 --- --- --- --- ---
20 --- --- --- --- ---
21 --- --- --- --- ---
22 --- --- --- --- ---
23 --- --- --- --- ---
24 --- --- --- --- ---
25 --- --- --- --- ---
06/07 Me-e-ZE ZE-11
Electric system MEDION TIC
Multifunction handle module A52:
Pin Function Component Measuring Direction Circuit
variable diagram no.
MFG-01 Raise reel S19 Earth Input 21
MFG-02 Lower reel S20 Earth Input 21
MFG-03 Reel forward S21 Earth Input 21
MFG-04 Reel reverse S22 Earth Input 21
MFG-05 Raise front attachment S56 Earth Input 20
MFG-06 Lower front attachment S66 Earth Input 20
MFG-07 Front attachment OFF S54 Earth Input 17
MFG-08 Grain tank unloading S31 Earth Input 15
MFG-09 CAC pre-set cutting height control S13 Earth Input 24
MFG-10 CAC cutting height control / S12 Earth Input 24
automatic ground pressure control
MFG-11 Swing out grain tank unloading S87 Earth Input 14
auger tube
MFG-12 Swing in grain tank unloading S88 Earth Input 14
auger tube
MFG-13 not used - - - -
MFG-14 not used - - - -
MFG-15 Switch earth supply Multi-funct. Earth Output 14, 15, 17,
handle 20, 21, 24
switch
MFA-01 Power supply plus a2 12 V Input 14, 15, 17,
20, 21, 24
MFA-02 not used - - - -
MFA-03 Raise front attachment Y85 Earth Output 20
MFA-04 Lower front attachment Y87 Earth Output 20
MFA-05 Raise reel Y22 Earth Output 21
MFA-06 Lower reel Y23 Earth Output 21
MFA-07 Reel forward Y24 Earth Output 21
MFA-08 Reel reverse Y25 Earth Output 21
MFA-09 Swing out grain tank unloading Y33 12 V Output 14
tube
MFA-10 Swing in grain tank unloading tube Y34 12 V Output 14
MFA-11 not used - - - -
MFA-12 not used - - - -
MFA-13 Ground speed control lever neutral Z57 12 V / 50a - 1
MFA-14 Ground speed control lever neutral Z57 12 V / 50a - 1
MFA-15 not used - - - -
MFB-01 Earth supply 31 Earth supply Input 14, 15, 17,
20, 21, 24
MFB-02 Earth supply 31 Earth supply Input 14, 15, 17,
20, 21, 24
MFB-03 CAC main switch S11 Earth Input 24
MFB-04 CAC ON A8/K55-85 Earth Output 24
MFB-05 Pre-set cutting height control ON A8 Earth Output 24
MFB-06 Front attachment ON main switch S55 Earth Input 17
MFB-07 Front attachment ON K78, K79 Earth Output 17
MFB-08 Grain tank unloading Y35 Earth Output 15
MFB-09 Grain tank unloading tube swung Z30 Earth Input 15
out
MFB-10 Seat contact Z5 Earth Output 14, 15, 17,
28
MFB-11 Program start S11 12 V Input 24
MFB-12 not used - - - -
MFB-13 not used - - - -
MFB-14 not used - - - -
MFB-15 not used - - - -
ZE-12 Me-e-ZE 06/07
TIC MEDION Electric system
Overview of fuses:
Fuse Circuit Circuit Circuit Circuit Circuit Circuit Circuit
Diagram Diagram Diagram Diagram Diagram Diagram Diagram
a1 34
a2 4 14 15 17 20 21 24
a3 34
a4
a5 32
a6 24 36
a7 32
a8 38
a9 12 24 26 30
a10 32
a11 37
a12 4
a13 32
a14 2
a15 7 15 17 19
a16 34
a17 8 20 21 23 40
a18 35
b1 33
b2 1 3 5 25 26 28 31
b3 30
b4 33
b5 31
b6 26 29 33 35 36
b7 34
b8 34
b9 35 39
b10 7 10 12 28 40
b11 10
b12 3 38
b13 10 25
b14 19
b15 3
b16 40
b17 38
b18 5 27
c1 17
F3 1 2
09/06 Me-e-ZE ZE-13
Electric system MEDION TIC
ZE-14 Me-e-ZE 06/07
1a
Main power supply,
Diesel engine electric starting motor
Electric system MEDION TIC
1a Main power supply, Diesel engine electric starting motor
Key to diagram: Coordinates
A15 Electronic engine control module (PLD) ................................5-i-18
G1 Battery....................................................................................6-n-20
G2 Generator ...............................................................................3-j-17
H19 Generator charging light ........................................................3-g-18
K11 Start relay...............................................................................4-h-17
K61 Generator release relay .........................................................4-g-17
M21 Electric starting motor ............................................................3-j-19
S25 Main drive (threshing mechanism clutch) ..............................3-h-17
S64 Ignition switch ........................................................................3-g-18
U21 Battery isolating switch ..........................................................6-n-20
Z57 Ground speed control lever safety start switch......................4-g-17
Measured value table: Item Component Measured value Remark
K11 Remote control relay 85±7 Ω (Pin 85 - Pin 86)
K61 20 A (Pin 30 - Pin 87a)
40 A (Pin 30 - Pin 87)
01a-2 Me-e-01a 09/06
TIC MEDION Electric system
Description of function:
A plus potential (+30) is fed in via the central power supply from the
positive terminal of battery (G1) and/or from generator (G2) pin 30. The
minus terminal of battery (G1) and the central earthing point (-31) are
connected to the machine chassis.
Ignition ON With the ignition switched on, battery plus (+30) is passed on as switched
plus (+15) via the ignition switch (S64).
Electric starting motor circuit The start relay K11 is used as safety start switch only if the ground speed
control lever is in neutral position and consequently the ground speed
control lever safety start switch (Z57) is closed. At the same time, the
threshing mechanism must be switched off at switch S 25. When the
power supply is applied at the electric starting motor, the start relay
(K11/87) applies a signal voltage in parallel to the electronic engine
control module (A15) and sets the electronic injection unit to start mode.
Generator release With the generator (G2) running, the generator release relay (K61)
switches battery plus (+15) on to generator release relay (K61/87). Perfect
generator function therefore is the pre-condition for the system operating
voltage (see circuit diagram 3).
Generator charging light With the ignition switched on, the generator charging light (H19) must light
up in order to excite the generator (G2) internally.
When the generator charging light (H19) lights up while the
engine/generator are running, no charging voltage is generated – a total
failure of the generator must be assumed. In this case, buzzer H 44 and
the signal lights "Stop" (H42) in the operations display screen and/or the
warning light (H45) on the vehicle information unit are permanently
activated as a warning (see circuit diagram 3).
09/06 Me-e-01a 01a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector LSBgr, MOBgr Connector MFAgn Connector LSCgr
Connector RT 1 Socket RT 1
Connector WS II Socket WS II
01a-4 Me-e-01a 09/06
TIC MEDION Electric system
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
LSAgr - 7 LSA 7 b2a 1.5 bk
LSBgr - 5 LSB 5 K61/86 MOB 15 KBA 7 0.75 bl
LSBgr - 13 MFA 14 LSB 13 0.75 bk/ye
LSCgr - 1 b2e LSC 2 a11e b15e a14e 4 bk
b3e b6e b9e b12e a9e
b18e
LSCgr - 2 b2e LSC 1 a11e b15e a14e 4 bk
b3e b6e b9e b12e a9e
b18e
LSCgr - 3 LSC 4 MOB 16 MOB 17 2.5 gr/rd
LSCgr - 4 LSC 3 MOB 16 MOB 17 2.5 gr/rd
LSCgr - 5 Z K54/30 c1e b5e b16e 4 rd
a6e b11e b14e b17e K60/30
K52/30 K53/30 a5e b7e LSC 6
LSCgr - 6 Z K54/30 c1e b5e b16e 4 rd
a6e b11e b14e b17e K60/30
K52/30 K53/30 a5e b7e LSC 5
MFAgn - 13 MOB 6 0.75 bk/ye
MFAgn - 14 LSB 13 0.75 bk/ye
MOBbr - 5 PHA 9 0.75 br/gr
MOBbr - 6 MFA 13 0.75 bk/ye
MOBbr - 15 LSB 5 K61/86 KBA 7 1 bl
RT 1 - 5 0.75 bl
WS II - 5 1.5 bk
09/06 Me-e-01a 01a-5
Electric system MEDION TIC
01a-6 Me-e-01a 09/06
2a
Starting the diesel engine,
diesel engine speed adjustment
Electric system MEDION TIC
2a Starting the diesel engine, diesel engine speed adjustment
Key to diagram: Coordinates
A15 Electronic engine control module...........................................5-i-18
A17 Engine adaptation module (ADM)..........................................4-h-17
DM Daimler-Chrysler diagnosis plug............................................4-h-17
F3 Engine fuse block...................................................................4-h-17
H50 Diesel engine oil pressure signal light ...................................3-g-18
P8 Engine temperature display ...................................................3-g-18
S35 Engine speed adjustment switch ...........................................4-h-17
Z41 Actual value switch
Road travel engine speed reduction ......................................7-i-18
02a-2 Me-e-02a 09/06
TIC MEDION Electric system
Description of function:
Diesel engine After actuating the engine speed adjustment switch S35, earth is applied
speed adjustment at the engine adaptation module A 17 both at pin 2/10 and at pin 2/6 when
switch Z 41 is closed. The engine is running at rated speed.
With 3rd gear engaged, transmission switch Z 41 is open, earth is now
applied only at pin 2/6. The engine is running at reduced speed (road
travel).
09/06 Me-e-02a 02a-3
Electric system MEDION TIC
Connector pin
assignment:
Socket A15 Socket A17 - 1 Socket A17 -2
Socket A17 -3 Socket A17 -4 Socket DM
Connector KNBge Connector MOBbr
02a-4 Me-e-02a 09/06
TIC MEDION Electric system
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
KNBge - 10 MOB 4 0.75 vi/bk
KNBge - 11 MOB 13 0.75 vi/bk
MOBbr - 3 a14a HKB21 1.5 bk/pi
MOBbr - 4 KNB 10 0.75 gn/bk
MOBbr - 13 KNB 11 1 bk/bl
09/06 Me-e-02a 02a-5
Electric system MEDION TIC
02a-6 Me-e-02a 09/06
3a
Diesel engine cut-off system
Electric system MEDION TIC
3a Diesel engine cut-off system
Key to diagram: Coordinates
A17 Engine adaptation module (ADM)..........................................4-h-17
DI Diode PCB .............................................................................4-g-17
H18 Cooling water level signal light ..............................................3-g-18
H21 Diesel engine STOP signal light ............................................3-g-18
H24 Diesel engine temperature signal light...................................3-g-18
H42 STOP signal light ...................................................................3-g-18
H44 Buzzer
H45 Warning light .........................................................................3-g-18
H46 Air filter maintenance signal light ...........................................3-g-18
H50 Diesel engine oil pressure signal light ...................................3-g-18
K58 Transducer.............................................................................4-g-17
K59 Engine oil pressure relay .......................................................4-g-17
K61 Generator release relay .........................................................4-g-17
K77 Warning buzzer relay .............................................................4-g-17
P8 Engine temperature display ...................................................3-g-18
Z32 Min. coolant level actual value switch....................................3-j-19
Z42 Diesel engine oil pressure actual value switch ......................4-j-17
Z69 Air filter maintenance actual value switch..............................3-j-17
Measured value table: Item Component Measured value Remark
K59 Remote control 95±10 Ω (Pin 85 - Pin 86)
relay 15 A (Pin 30 - Pin 87a)
30 A (Pin 30 - Pin 87)
K61 Remote control 85±7 Ω (Pin 85 - Pin 86)
relay 20 A (Pin 30 - Pin 87a)
40 A (Pin 30 - Pin 87)
Z69 Pressure switch - 50±5 mbar
3a-2 Me-e-03a 06/07
TIC MEDION Electric system
Description of function:
Engine oil pressure warning If the engine oil pressure falls during operation (relay K61 actuated), the
oil pressure switch Z 42 closes and earth is applied to pin 85 of relay K 59
– the relay switches. The following items are activated permanently in
this case:
- Buzzer H 44 (pulse-type buzzer)
- Warning lights H 42 in the operations display screen
- Warning light H 45 on vehicle information unit
- Warning light H 50 engine oil pressure over diode PCB
- Warning light H 21 is activated.
This earth is simultaneously applied as a signal to module A 17.
Important! When the oil pressure is too low, there is no automatic
engine cut-off. The oil pressure switch Z 42 only switches
the warning instruments. Another oil pressure switch
(Daimler/Chrysler component) here provides automatic
power reduction.
Temperature display The temperature sensor (Daimler/Chrysler component) transmits its signal
to the electronic engine control module A15. From there, this signal is
passed on to the engine adaptation module A 17 via the CAN bus.
The engine adaptation module A 17 converts the digital signal into an
analogue signal and transmits it to indicator P8.
Important! When the temperature signal exceeds the defined limit
value, the electronic engine control module A15
automatically reduces the engine power. One acoustic
and optical warning is given in case of excess temperature.
Overtemperature warning The “Overtemperature warning” can be caused by several events:
- cooling water temperature signal too high while engine power is
reduced
- low oil pressure
- low oil level (when oil level sensor is parameterized)
The engine adaptation module (A17) actuates the signal light H24 and the
warning buzzer K77 at the same time via the relay.
- Buzzer (pulse buzzer) H 44
- Warning lights H 42 in the operations display screen
- Warning light H 45 on vehicle information unit
Air filter warning In case of excessive air filter clogging, switch Z 69 closes. In this case,
warning lights H 46 and warning light H 21 via the diode PCB are
activated permanently.
At the same time, the following items are activated in a pulsed way via
pulse relay K 58:
- Buzzer H 44 (pulse-type buzzer)
- Warning lights H 42 in the operations display screen
- Warning light H 45 on the vehicle information unit is activated
permanently.
Coolant level warning Ignition ON, diesel engine is not started (relay K 61 is not actuated). In
case the coolant level is too low, switch Z 33 closes.
In this case, warning light H 18 lights up permanently.
06/07 Me-e-03a 3a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector LSBgr, MOBbr, Connector LSAgr Connector
PHAbl, PVAge, PVBge RT 1, WS II
Socket
RT 1, WS II
3a-4 Me-e-03a 06/07
TIC MEDION Electric system
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
LSAgr - 7 b2a 1.5 bk
bk/br
LSAgr - 9 PVB 21 K59/30 K77/87 PHA - 4 0.75
LSBgr - 1 MOB 11 0.75 wh/rd
LSBgr - 2 K59/85 DI 13 MOB 7 0.5 gn/gr
LSBgr - 3 DI 12 MOB 8 0.75 bl/ye
LSBgr - 4 EARTH PVA 21 PVB 6 MFA 1 MFA 2 1.5 br
LSB 10 FSA 5 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 LSA 1 HDA 8 MOB 2 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
K49/85 K50/85 K73/31 KBB 12 BFA 2
LSBgr - 6 DI 14 MOB 12 0.75 ye/bl
LSBgr - 8 DI 10 0.5 bl/br
LSBgr -10 EARTH PVA 21 PVB 6 MFA 1 MFA 2 1.5 br
LSB 4 FSA 5 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 LSA 1 HDA 8 MOB 2 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
K49/85 K50/85 K73/31 KBB 12 BFA 2
MOBbr - 7 LSB 2 K59/85 DI 13 1 gn
MOBbr - 8 LSB 3 DI 12 1 bl/ye
MOBbr -11 LSB 1 1 wh/rd
MOBbr -12 LSB 6 DI 14 bl/wh
MOBbr -19 PVB 14 1 ye/br
PHAbl - 2 EARTH PVA 21 PVB 6 MFA 1 MFA 2 1.5 br
LSB 4 FSA 5 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 LSA 1 HDA 8 MOB 2 FSA 1
APA 8 MOA 2 HKA 19 LSB 10 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
K49/85 K50/85 K73/31 KBB 12 BFA 2
PHAbl - 4 PVBge - 21 K59/30 K77/87 LSAgr - 9 0.75 bk/br
06/07 Me-e-03a 3a-5
Electric system MEDION TIC
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
PHAbl - 5 EARTH PVA 21 PVB 6 MFA 1 MFA 2 1.5 br
LSB 4 FSA 5 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 LSA 1 HDA 8 MOB 2 FSA 1
APA 8 MOA 2 HKA 19 LSB 10 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
K49/85 K50/85 K73/31 KBB 12 BFA 2
PVAge -17 K59/87a K61/87a 0.5 bk/bl
PVBge - 6 EARTH PVA 21 PHA 2 MFA 1 MFA 2 0.75 br
LSB 4 FSA 5 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA17 LSA 1 HDA 8 MOB 2 FSA 1
APA 8 MOA 2 HKA 19 LSB 10 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA5
KBA9 KBA10 K54/85 ZGA 3 ZGA 4
K49/85 K50/85 K73/31 KBB 12 BFA 2
EARTH PVA 21 PVB 6 MFA 1 MFA 2
PVBge - 14 MOB 19 0.5 ye/br
PVBge - 21 PHA 4 LSA 9 K59/30 0.75 bk/br
RT1 - 1 0.75 wh/rd
RT1 - 2 0.5 gn/gr
RT1 - 3 0.75 bl/ye
RT1 - 4 1.5 br
RT1 - 6 0.75 ye/bl
RT1 - 8 0.5 bl/br
RT1 -10 1.5 br
WSII - 5 1.5 bk
WSII - 7 0.75 bk/br
3a-6 Me-e-03a 06/07
4a
Activation of road travel,
master valve
Electric system MEDION TIC
4a Activation of road travel, master valve
Key to diagram: Coordinates
DO Master valve diode PCB ........................................................4-g-17
K60 Road travel release relay .......................................................4-g-17
K61 Alternator release relay..........................................................4-g-17
S52 Road travel switch (red) .........................................................4-h-17
Y77 Working hydraulics master valve solenoid coil ......................5-i-19
Measured value table: Item Component Measured value Remark
K60 Remote control relay 85±7 Ω (Pin 85 - Pin 86)
20 A (Pin 30 - Pin 87a)
40 A (Pin 30 - Pin 87)
Y77 Solenoid coil 3.8 A See lettering
3.2 Ω
4a-2 Me-e-04a 06/07
TIC MEDION Electric system
Description of function:
Release of road travel After actuating the Road travel switch S 52, the voltage applied at branch
K 61/87 is passed on via relay K 60. The new branch K60/87 thus created
supplies most of the electro-hydraulic circuits.
Master valve In order to be able to build up the necessary working pressure for many
hydraulic controls, the neutral hydraulic circulation must be blocked (see
also the "Hydraulic system" section). In this case, the master valve
solenoid coil (Y77) is actuated directly via the diode PCB (DO) in parallel
with the function.
09/06 Me-e-04a 4a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector HDAge, PHAbl Socket Y77
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
PHAbl - 6 a12a 1.5 bk
PHAbl - 7 HDA 12 PVC 9 K60/86 CAC 1 KNB 2 1.5 bl/gn
K56/86
HDAge - 8 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.5 br
LSA 1 LSB 10 LSB 4 PVC 12 CAC 8
CAC 17 HDA 8 AP 8 AP 9 KBB 6
KBB 8 K60/85 MOB 2 KBA 17 K64/85
VSA 4 DO 22 FSA 1 FSA 5 APA 8
MOA 2 HKA 19 PHA 2 KNA 2 K49/85
K79/30 K57/31 K61/85 K52/85 K53/85
K50/85 K66/85 K69/87a K70/87a K71/87a
K72/87a K75/85 K77/85 BFA 3 ASA 1
KBA 5 KBB 12 KBA 9 KBA 10 K54/85
ZGA 3 ZGA 4 BFA 2
HDAge-16 DO21
HDAge-19 DO 15
HDAge-20 DO 2
04a-4 Me-e-02a 09/06
5a
Fieldwork computer
Electric system MEDION TIC
5a Fieldwork computer
Key to diagram: Coordinates
A29 Fieldwork computer terminal..................................................3-f-17
B10 Diesel engine speed sensor...................................................5-i-20
B11 Threshing drum speed sensor ...............................................6-i-19
B15 Fan speed sensor ..................................................................7-l-16
B16 Transmission speed sensor (ground speed) .........................7-i-18
B16a Transmission speed sensor (ground speed) .........................7-i-16
P13 Ground speed display ............................................................4-g-17
Z71 Front attachment working position actual value switch .........5-g-17
Measured value table: Item Component Measured Remark
value
B10 Sensor 1000-1200 Ω inductive
B11
B15
B16
B16a Sensor I-0 Reed contact
05a-2 Me-e-02a 09/06
TIC MEDION Electric system
Description of function:
Performance data (area The signals from the front attachment working position actual value switch
counter) Z71 and from the transmission speed sensor B16a are read into the
fieldwork computer terminal A16. According to the programming, the
terminal processes these values to obtain performance data which can be
read out.
(see Fieldwork Computer Operating Manual)
Extended machine The signals of sensors B10, B11 and B15 are detected by the fieldwork
monitoring computer terminal A16 and processed there.
For extended machine monitoring, corresponding alarm messages are
allocated to the programmed limit values.
(see Fieldwork Computer Operating Manual)
09/06 Me-e-05a 05a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector KBAgn, KNAge, Connector Connector
LSBgr, PVBge BFAgr, KNBge, LSAgr MOAbr
Connector RT 1, WS II Socket RT 1, WS II
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
KNAge - 2 EARTH PVA 21 PVB 6 MFB 1 MFB 2 0.75 br
LSA 10 LSB 10 LSB 4 PVC 12 CAC 8
CAC 17 HDA 8 AP 8 AP 9 KBB 6
KBB 8 K60/85 MOB 2 KBA 17 K64/85
VSA 4 DO 22 FSA 1 FSA 5 APA 8
MOA 2 HKA 19 PHA 2 KANN 2 K49/85
K79/30 K57/31 K61/85 K52/85 K53/85
K50/85 K66/85 K69/87a K70/87a K71/87a
K72/87° K75/85 K77/85 BFA 3 ASA 1
KBA 5 KBB 12 KBA 9 KBA 10 K54/85
ZGA 3 ZGA 4 BFA 2
KNAge - 13 LSA 8 0.75 bk/wh
KNBge - 13 PVB 15 BFA 9 0.75 rd/bk
KNBge - 14 0.75 rd/bl
LSAgr - 7 b2a 1.5 bk
LSAgr - 8 KNA 13 0.5 gn/ye
05a-4 Me-e-02a 09/06
TIC MEDION Electric system
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
LSBgr -10 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.5 br
LSA 1 LSB 10 LSB 4 PVC 12 CAC 8
CAC 17 HDA 8 AP 8 AP 9 KBB 6
KBB 8 K60/85 MOB 2 KBA 17 K64/85
VSA 4 DO 22 FSA 1 FSA 5 APA 8
MOA 2 HKA 19 PHA 2 KNA 2 K49/85
K79/30 K57/31 K61/85 K52/85 K53/85
K50/85 K66/85 K69/87a K70/87a K71/87a
K72/87a K75/85 K77/85 BFA 3 ASA 1
KBA 5 KBB 12 KBA 9 KBA 10 K54/85
ZGA 3 ZGA 4 BFA 2
MOBbr -14 DZW 5 BFA 4 1 rd/ye
PVBge -15 KNB 13 0.5 rd
RT 1 -10 1.5 br
WS II - 5 1.5 bk
WS II - 6 0.5 gn/ye
09/06 Me-e-05a 05a-5
Electric system MEDION TIC
05a-6 Me-e-05a 09/06
7a
Threshing mechanism circuit
Electric system MEDION TIC
7a Threshing mechanism circuit
Key to diagram: Coordinates
K63 Threshing mechanism relay...................................................4-g-17
S25 Main drive switch (threshing mechanism clutch) ...................3-h-17
Y21 Threshing mechanism clutch solenoid coil ............................5-j-19
Measured value table: Item Component Measured Remark
value
K63 Remote control relay 95±10 Ω (Pin 85 - pin 86)
15 A (Pin 30 - pin 87a)
30 A (Pin 30 - pin 87)
Y21 Solenoid coil 0.75 A / 16 Ω See lettering
07a-2 Me-e-07a 09/06
TIC MEDION Electric system
Description of function:
Threshing mechanism The threshing mechanism clutch solenoid coil (Y21) is supplied with
circuit power via the threshing mechanism relay (K63) after actuating the
threshing mechanism clutch switch (S25).
09/06 Me-e-07a 07a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector
MOAbr, PHAbl Socket Y21
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
MOAbr - 1 PHA 15 PVA 1 b10a K71/86 K72/86 1 bk/gr
PHAbl - 2 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.5 br
LSA 1 LSB 10 LSB 4 PVC 12 CAC 8
CAC 17 HDA 8 AP 8 AP 9 KBB 6
KBB 8 K60/85 MOB 2 KBA 17 K64/85
VSA 4 DO 22 FSA 1 FSA 5 APA 8
MOA 2 HKA 19 PHA 2 KNA 2 K49/85
K79/30 K57/31 K61/85 K52/85 K53/85
K50/85 K66/85 K69/87a K70/87a K71/87a
K72/87a K75/85 K77/85 BFA 3 ASA 1
KBA 5 KBB 12 KBA 9 KBA 10 K54/85
ZGA 3 ZGA 4 BFA 2
PHAbl - 9 MOB 5 0.75 bl/gn
PHAbl - 11 PVC 21 1.5 bk/ye
PHAbl - 12 K63/85 K78/30 1.5 gn/wh
07a-4 Me-e-07a 09/06
8a
Threshing drum variable-speed drive
Electric system MEDION TIC
8a Threshing drum variable-speed drive
Key to diagram: Coordinates
DO Master valve diode PCB ..................................................... 4-g-17
S65 Threshing drum / fan speed changeover ........................... 4-g-17
S98 Threshing drum speed adjustment switch.......................... 4-g-17
Y19 Threshing drum variable-speed drive slow solenoid coil.... 5-h-17
Y20 Threshing drum variable-speed drive fast solenoid coil ..... 5-h-17
Measured value table: Item Component Measured Remark
value
Y19 Solenoid coil 3.8 A See lettering
Y20 3.2 Ω
08a-2 Me-e-08a 09/06
TIC MEDION Electric system
Description of function:
Threshing drum variable- The threshing mechanism clutch switch (S25) must be closed before the
speed drive threshing drum variable-speed drive can be adjusted.
Moreover, the changeover switch (S65) must be set to the threshing drum
display. See circuit diagram 10
Only when these conditions have been met, earth is applied to the
threshing drum speed adjustment switch (S98) which enables increasing
(Y20) or decreasing the threshing drum speed.
The master valve (Y77) is also actuated via the diode PCB (DO) in
parallel with the threshing drum speed adjustment because the threshing
drum speed increase function (Y20) requires that pressure is built up in
the system.
09/06 Me-e-08a 08a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector
HDAge, PVAge Socket Y19, Y20
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
PVAge - 4 HDA 17 DO 9 1,5 wh/rd
PVAge - 14 HDA 18 DO 10 1,5 wh/bl
HDAge - 1 ASA 3 HDA 1 a17a VSA 1 1,5 bk/vi
HDAge - 17 DO 9 1,5 wh/rd
HDAge - 18 DO 10 1,5 wh/bl
08a-4 Me-e-08a 09/06
10a
Fan variable-speed drive
Electric system MEDION TIC
10a Fan variable-speed drive
Key to diagram: Coordinates
B11 Threshing drum sensor ..........................................................6-i-19
B15 Fan sensor .............................................................................7-l-16
E35 Instrument lighting..................................................................4-g-17
H48 Threshing drum signal light....................................................4-g-17
H49 Fan signal light.......................................................................4-g-17
K61 Alternator release relay..........................................................4-g-17
K71 Fan speed relay .....................................................................4-g-17
K72 Fan speed relay .....................................................................4-g-17
M3 Fan speed adjustment motor .................................................5-l-19
P1 Hour meter indicator ..............................................................4-g-17
P3 Speed indicator ......................................................................4-g-17
S18 Fan speed adjustment switch ................................................4-g-17
S65 Threshing drum / fan speed changeover switch....................4-g-17
Measured value table: Item Component Measured Remark
value
B11 Sensor 1000 - 1200 Ω inductive
B15
K71 Remote control relay 85±7 Ω (Pin 85 - Pin 86)
K72 20 A (Pin 30 - Pin 87a)
40 A (Pin 30 - Pin 87)
M3 Engine 12 - 15 A Short-circuit current
2-4A Working current
10a-2 Me-e-10a 09/06
TIC MEDION Electric system
Description of function:
Fan speed adjustment The fan speed adjustment electric motor M3 rotates clockwise or
circuit counterclockwise by means of switch S18 and relay K71 or K72.
Adjustments are only allowed while the fan is running.
Important! The power supply of relays K71 and K72 depends on the
threshing mechanism relay K63 (see corresponding
section). Adjustments of the fan speed are possible only
when switch S65 (Threshing drum / fan speed changeover)
is set to "Fan".
Threshing drum speed If the threshing drum speed is to be displayed, switch S65 (Threshing
indicator drum / fan speed changeover) must be set to "Threshing drum". In this
case, the threshing drum symbol (H48) is lighted and the corresponding
signals from the threshing drum speed sensor are processed in indicator
P3.
Fan speed indicator If the fan speed is to be displayed, switch S65 (Threshing drum / fan
speed changeover) must be set to "Fan". In this case, the fan symbol
(H49) is lighted and the corresponding signals from the fan speed sensor
are processed in indicator P3.
Hour meter indicator When voltage from the branch K61/87 (generator) is applied at the hour
meter P1, the hours worked are displayed.
09/06 Me-e-10a 10a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector HKAbl, KNAge, Connector KNBge
PVAge, PVCge, MOBbr
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
HKAbl - 17 K72/30 2.5 wh/ye
HKAbl - 18 K71/30 2.5 wh/ye
HKAbl - 19 EARTH PVA 21 PVB 6 MFB 1 MFB 2 0.75 br
LSA 1 LSB 10 LSB 4 PVC 12 CAC 8
CAC 17 HDA 8 AP 8 AP 9 KBB 6
KBB 8 K60/85 MOB 2 KBA 17 K64/85
VSA 4 DO 22 FSA 1 FSA 5 APA 8
MOA 2 HKA 19 PHA 2 KNA 2 K49/85
K79/30 K57/31 K61/85 K52/85 K53/85
K50/85 K66/85 K69/87a K70/87a K71/87a
K72/87a K75/85 K77/85 BFA 3 ASA 1
KBA 5 KBB 12 KBA 9 KBA 10 K54/85
ZGA 3 ZGA 4 BFA 2
HKAbl - 20 PVA 16 BFA 8 0.75 bl/wh
KNAge - 2 EARTH PVA 21 PVB 6 MFB 1 MFB 2 0.75 br
LSA 1 LSB 10 LSB 4 PVC 12 CAC 8
CAC 17 HDA 8 AP 8 AP 9 KBB 6
KBB 8 K60/85 MOB 2 KBA 17 K64/85
VSA 4 DO 22 FSA 1 FSA 5 APA 8
MOA 2 HKA 19 PHA 2 KNA 2 K49/85
K79/30 K57/31 K61/85 K52/85 K53/85
K50/85 K66/85 K69/87a K70/87a K71/87a
K72/87a K75/85 K77/85 BFA 3 ASA 1
KBA 5 KBB 12 KBA 9 KBA 10 K54/85
ZGA 3 ZGA 4 BFA 2
KNBge - 12 PVA 15 MOB 1 BFA 7 0.75 bl/vi
10a-4 Me-e-10a 09/06
TIC MEDION Electric system
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
PVAge -12 K71/85 0.75
PVAge -13 K72/85 0.75
PVAge -15 MOB 1 KNB 12 BFA 7 0.75
PVAge -16 HKA 20 BFA 8 0.75
PVAge -21 EARTH PVA 21 PVB 6 MFB 1 MFB 2
LSA 1 LSB 10 LSB 4 PVC 12 CAC 8
CAC 17 HDA 8 AP 8 AP 9 KBB 6
KBB 8 K60/85 MOB 2 KBA 17 K64/85
VSA 4 DO 22 FSA 1 FSA 5 APA 8
MOA 2 HKA 19 PHA 2 KNA 2 K49/85
K79/30 K57/31 K61/85 K52/85 K53/85
K50/85 K66/85 K69/87a K70/87a K71/87a
K72/87a K75/85 K77/85 BFA 3 ASA 1
KBA 5 KBB 12 KBA 9 KBA 10 K54/85
ZGA 3 ZGA 4 BFA 2
PVCge - 6 DZW 8 b13a DI 11 0.5 wh/ye
09/06 Me-e-10a 10a-5
Electric system MEDION TIC
10a-6 Me-e-10a 09/06
12a
Deflector adjustment,
performance monitor
Electric system MEDION TIC
12a Deflector adjustment, performance monitor
Key to diagram: Coordinates
A26 Deflector adjustment module ................................................. 5-h-16
B31 Sensor
Cleaning performance monitor .............................................. 6-q-18
B32 Sensor
Residual separation performance monitor............................. 4-s-18
K63 Threshing mechanism relay................................................... 4-g-17
K86 Deflector adjustment relay ..................................................... 5-h-16
M22 Deflector adjustment motor.................................................... 6-u-17
P4 Indicator
Separation performance monitor ........................................... 4-g-17
P5 Indicator
Cleaning performance monitor .............................................. 4-g-17
R6 Potentiometer
Cleaning performance monitor sensitivity.............................. 4-g-17
R7 Potentiometer
Residual separation performance monitor sensitivity............ 4-g-17
R28 Potentiometer
Spreading direction potentiometer (actual value).................. 6-u-17
R29 Potentiometer
Spreading direction potentiometer (set value)....................... 4-g-17
Measured value table: Item Component Measured Remark
value
K86 Remote control relay 85±7 Ω (Pin 85 - Pin 86)
20 A (Pin 30 - Pin 87a)
40 A (Pin 30 - Pin 87)
M22 Engine 5.5 A Short-circuit current
0.7 A Working current
R6 Potentiometer 0 - 11 kΩ
R7
R28 Potentiometer 0.2 - 5.0 kΩ Coil
0.15 - 4.85 V Signal
R29 Potentiometer 4.70 kΩ (Pin A - E) coil
1.7 - 6.4 kΩ (Pin S - E) slider
12a-2 Me-e-12a 09/06
TIC MEDION Electric system
Description of function:
Deflector adjustment The deflector adjustment module (A26) is supplied with power via relay
K86 when the threshing mechanism is engaged. According to the setting
of the set value potentiometer (R29) in the cab, the deflector adjustment
module (A26) controls the deflector adjustment motor (M22) until the set
value matches that of the integrated actual value potentiometer (R28).
Performance monitor Depending on the crop to be harvested, the performance monitor sensors
allow a rough sensitivity adjustment (coarse/medium/fine). The indicator
may be fine-adjusted at the potentiometers R6 / R7.
09/06 Me-e-12a 12a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector
HKAbl, PHAbl, PVBge
12a-4 Me-e-12a 09/06
TIC MEDION Electric system
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
HKAbl - 12 PVB 16 0.75 vi/gn
HKAbl - 13 PVB 17 0.75 vi/wh
M22 - 1 6.0 ye
M22 - 2 6.0 wh
M22 - 3 1.0 bk/gn
M22 - 4 1.0 bl
M22 - 5 1.0 br/ye
P4 - 1 0.25 br
P4 - 2 0.25 gn
P4 - 3 0.25 wh
P5 - 1 0.35 bk
P5 - 2 0.35 gn
P5 - 5 0.35 wh
P5 - 6 0.5 br
PHAbl - 15 PVA 1 b10a MOA 1 K71/86 K72/86 1.5 bk/gr
PVBge - 6 EARTH PVA 21 PVB 6 MFB 1 MFB 2 0.75 br
LSA 1 LSB 10 LSB 4 PVC 12 CAC 8
CAC 17 HDA 8 AP 8 AP 9 KBB 6
KBB 8 K60/85 MOB 2 KBA 17 K64/85
VSA 4 DO 22 FSA 1 FSA 5 APA 8
MOA 2 HKA 19 PHA 2 KNA 2 K49/85
K79/30 K57/31 K61/85 K52/85 K53/85
K50/85 K66/85 K69/87a K70/87a K71/87a
K72/87a K75/85 K77/85 BFA 3 ASA 1
KBA 5 KBB 12 KBA 9 KBA 10 K54/85
ZGA 3 ZGA 4 BFA 2
PVBge - 7 a9a 0.5 bk
PVBge - 16 HKA 12 0.5 gn
PVBge - 17 HKA 13 0.5 wh
R29 - 1 0.5 bk/gn
R29 - 2 0.5 rd
R29 - 3 0.5 br/ye
R6 / R7 - 1 0.25 br
R6 / R7 - 2 0.25 gn
R6 / R7 - 3 0.25 wh
09/06 Me-e-12a 12a-5
Electric system MEDION TIC
12a-6 Me-e-12a 09/06
14a
Swinging the grain tank unloading tube
Electric system MEDION TIC
14a Swinging the grain tank unloading tube
Key to diagram: Coordinates
A52 Multi-function handle module (MFG) ....................................4-g-17
DO Master valve diode PCB ........................................................4-g-17
K60 Road travel release relay .......................................................4-g-17
S87 Swing out grain tank unloading tube switch KT .....................4-f-17
S88 Swing in grain tank unloading tube switch KT .......................4-f-17
Y33 Solenoid coil
Swinging out the grain tank unloading tube...........................5-h-16
Y34 Solenoid coil
Swinging in the grain tank unloading tube .............................5-h-16
Z5 Seat contact actual value switch............................................4-h-18
Measured value table: Item Component Measured Remark
value
Y33 Solenoid coil 3.8 A See lettering
Y34 3.2 Ω
14a-2 Me-e-14a 09/06
TIC MEDION Electric system
Description of function:
Grain tank unloading tube The grain tank unloading tube swing function is controlled by the multi-
swing circuit function handle module (A52).
With the road travel circuit unlocked, module (A52) is supplied with power.
The seat contact (Z5) must also be actuated.
Depending on the direction (swinging in or out), the switches (S87/S88)
transmit an earth signal to the multi-function handle module (A52). Module
A52 actuates the corresponding solenoid coil, i.e. grain tank unloading
tube swing out (Y33) or grain tank unloading tube swing in (Y34).
The master valve (Y77) is also actuated via the diode PCB (DO) in
parallel with the solenoid coils (Y33/Y34) because this function requires
that pressure is built up in the system.
Swing grain tank unloading When one of the switches (S87 / S88) is actuated for more than 1.25
tube time control seconds, the Swing grain tank unloading tube function remains active for
30 seconds.
Actuating one of the switches (S87 / S88) one more time briefly stops
swinging in/out of the grain tank unloading tube.
09/06 Me-e-14a 14a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector HDAge Connector MFAgn, MFBgr Connector MFG
Socket Y33, Y34
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
HDAge - 8 1.5 br
MFB 1 0.75 br
MFB 2 EARTH PVA 21 PVB 6 MFB 1 MFB 2 0.75 br
LSA 1 LSB 10 LSB 4 PVC 12 CAC 8
CAC 17 HDA 8 AP 8 AP 9 KBB 6
KBB 8 K60/85 MOB 2 KBA 17 K64/85
VSA 4 DO 22 FSA 1 FSA 5 APA 8
MOA 2 HKA 19 PHA 2 KNA 2 K49/85
K79/30 K57/31 K61/85 K52/85 K53/85
K50/85 K66/85 K69/87a K70/87a K71/87a
K72/87a K75/85 K77/85 BFA 3 ASA 1
KBA 5 KBB 12 KBA 9 KBA 10 K54/85
ZGA 3 ZGA 4 BFA 2
HDAge -10 MFAgn 9 1.5 bl
HDAge -11 MFAgn 10 1.5 vio
14a-4 Me-e-14a 09/06
15a
Grain tank unloading
Electric system MEDION TIC
15a Grain tank unloading
Key to diagram: Coordinates
A52 Multi-function handle module (MFG) ....................................4-g-17
H13 Unloading tube position signal light .......................................4-g-17
H14 Grain tank unloading signal light............................................4-g-17
K60 Road travel release relay .......................................................4-g-17
S31 Grain tank unloading switch...................................................5-g-19
Y35 Grain tank unloading solenoid coil.........................................5-j-19
Z5 Seat contact actual value switch............................................4-h-18
Z30 Grain tank unloading tube swung out actual value switch.....4-l-20
Measured value table: Item Component Measured Remark
value
Y35 Solenoid coil 0.75 A / 16 Ω See lettering
15a-2 Me-e-15a 09/06
TIC MEDION Electric system
Description of function:
Grain tank unloading circuit The grain tank unloading solenoid coil (Y35) is energized by grain tank
unloading switch (S31) via the multi-function handle module (A52).
This requires that the unloading tube is swung out (Z30 closed) and the
seat contact (Z5) is actuated.
09/06 Me-e-15a 15a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector PVBge, HKBbl Connector MFAgn, MFBgr Connector MFG
Connector MOAbr Socket Y35
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
HKAbl - 21 PVB 10 MFB 9 1.5 gr/vi
MOAbr - 5 PVB 5 MOA 4 K69/86 K70/86 1 bk
K63/86 K78/86 K79/86
MOAbr - 6 PVB 11 MFB 8 1 bk/or
PVBge - 5 MOA 4 MOA 5 K69/86 K70/86 K77/87a 0.75 vi/ye
K63/86 K78/86 K79/86
PVBge -10 HKA 21 MFB9 0.75 gr/vi
PVBge -11 MOA 6 MFB8 0.75 bk/or
15a-4 Me-e-15a 09/06
17a
Front attachment drive, reverser drive
Electric system MEDION TIC
17a Front attachment drive
Key to diagram: Coordinates
A52 Multi-function handle module (MFG) .....................................4-g-17
DO Master valve diode PCB ........................................................4-g-17
K60 Road travel release relay .......................................................4-g-17
K62 Front attachment reverse relay..............................................4-g-17
K77 Safety shutdown switch relay ................................................4-g-17
K78 Front attachment identification relay......................................4-g-17
K79 Front attachment identification relay......................................4-g-17
M24 Front attachment reverse motor ............................................7-e-17
S25 Main drive switch (threshing mechanism clutch) ...................4-h-17
S54 Front attachment OFF switch.................................................5-g-19
S55 Front attachment ON switch ..................................................4-h-17
S57 Front attachment reverse switch............................................4-g-17
Y88 Front attachment clutch solenoid coil ....................................5-j-19
Z5 Seat contact actual value switch............................................4-h-18
Measured value table: Item Component Measured Remark
value
K62 Remote control relay 85±7 Ω (Pin 85 - pin 86)
20 A (Pin 30 - pin 87a)
40 A (Pin 30 - pin 87)
K78 Remote control relay 95±10 Ω (Pin 85 - pin 86)
K79 15 A (Pin 30 - pin 87a)
30 A (Pin 30 - pin 87)
Y86 Solenoid coil 3.8 A See lettering
3.2 Ω
Y88 Solenoid coil 0.75 A See lettering
16 Ω
17a-2 Me-e-17a 09/06
TIC MEDION Electric system
Description of function:
Front attachment The following pre-conditions must be met for the front attachment drive to
circuit be switched on:
- Road travel switch (S52) unlocked
- Relay K60 energized
- Main drive (threshing mechanism clutch) engaged (S25)
- Seat contact (Z5) actuated
- Zero position S55 When touch sensor S55 is in zero position, pins 3+4 are open,
pin 5+6 are closed.
- Front attachment When actuating touch sensor S55 (pins 3+4 closed, pins 5+6 closed),
ON earth is applied to solenoid coil Y88 –
the front attachment is engaged.
The multi-function handle module (A52) switches in parallel via S55 (pins
5 + 6) and remains locked in so that the front attachment remains
engaged even after releasing pushbutton S55 (neutral position).
Important! The earth supply of the front attachment clutch solenoid coil
(Y88) depends on relay K78.
When the front attachment OFF switch (S54) is actuated,
the multi-function handle module (A52) does not energize
relay K78 any more.
- Front attachment After pressing pushbutton S55 (pins 5 + 6 open), the internal locking in
OFF the multi-function handle module (A52) is interrupted. The front
attachment disengages.
Seat contact circuit After leaving the operator's seat, all circuits depending on the seat
contact are interrupted after approx. 5 seconds (front attachment
disengages).
Reversing safety When engaging the front attachment, relay K79 is also actuated in
circuit parallel and cuts the earth supply to the front attachment reverse
pushbutton S57. Reversing therefore is possible only with the front
attachment disengaged.
Reversing circuit During reversing, the electric motor M24 is switched on by switch S57
(hydraulic) via relay K62.
The master valve (Y77) is also actuated via the diode PCB (DO) in
parallel with the solenoid coil (Y86) because this function requires that
pressure is built up in the system.
Important! The earth supply of pushbutton S57 depends on relay
K79 – Reversing safety circuit.
09/06 Me-e-17a 17a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector HDAge, PHAbl, Connector MFAgn, MFBgr Connector MOAbr
Connector MFG Connector S55 Socket Y86, Y88
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
HDAge - 8 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.5 br
LSA 1 LSB 10 LSB 4 PVC 12 CAC 8
CAC 17 HDA 8 AP 8 AP 9 KBB 6
KBB 8 K60/85 MOB 2 KBA 17 K64/85
VSA 4 DO 22 FSA 1 FSA 5 APA 8
MOA 2 HKA 19 PHA 2 KNA 2 K49/85
K79/30 K57/31 K61/85 K52/85 K53/85
K50/85 K66/85 K69/87a K70/87a K71/87a
K72/87a K75/85 K77/85 BFA 3 ASA 1
KBA 5 KBB 12 KBA 9 KBA 10 K54/85
ZGA 3 ZGA 4 BFA 2
HDAge - 15 MOB 18 K62/87 DO 14 1.5 gn
MFAgn - 1 DO 1 a2a HDA 9 0.75 bk
MFBgr - 1 EARTH PVA 21 PVB 6 MFB 1 MFB 2 0.75 br
MFBgr - 2 LSA 1 LSB 10 LSB 4 PVC 12 CAC 8 0.75 br
CAC 17 HDA 8 AP 8 AP 9 KBB 6
KBB 8 K60/85 MOB 2 KBA 17 K64/85
VSA 4 DO 22 FSA 1 FSA 5 APA 8
MOA 2 HKA 19 PHA 2 KNA 2 K49/85
K79/30 K57/31 K61/85 K52/85 K53/85
K50/85 K66/85 K69/87a K70/87a K71/87a
K72/87a K75/85 K77/85 BFA 3 ASA 1
KBA 5 KBB 12 KBA 9 KBA 10 K54/85
ZGA 3 ZGA 4 BFA 2
17a-4 Me-e-17a 09/06
TIC MEDION Electric system
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
MFBgr -6 PHA 16 0,75 br/ye
MFBgr -7 K78/85 K79/85 0,75 br/ye
MOAbr - 3 PHA 13 PVB 1 K78/87 PHA 17 1,0 br/ye
MOAbr - 4 PVB 5 MOA 5 K63/86 K69/86 K70/86 1,0 bk
K78/86 K79/86 a15a
PHAbl - 1 K62/85 0,5 br/gr
PHAbl - 10 K79/87a 0,75 br/bl
PHAbl - 12 K63/85 K78/30 1,5 gn/wh
PHAbl - 13 PVB 1 K78/87 MOA 3 PHA 17 1,5 br/ye
PHAbl - 16 MFB 6 0,75 br/ye
PHAbl - 17 PVB 1 K78/87 MOA 3 PHA 17 0,75 br/ye
09/06 Me-e-17a 17a-5
Electric system MEDION TIC
17a-6 Me-e-17a 09/06
19a
Reel variable-speed drive
Electric system MEDION TIC
19a Reel variable-speed drive
Key to diagram: Coordinates
K69 Reel speed adjustment relay ..............................................4-g-17
K70 Reel speed adjustment relay ..............................................4-g-17
K77 Safety shutdown switch relay .............................................4-g-17
K78 Front attachment identification relay...................................4-g-17
M6 Reel speed adjustment motor.............................................. 5-l-19
S24 Reel speed adjustment switch............................................4-g-17
Measured value table: Item Component Measured Remark
value
K69 Remote control relay 85±7 Ω (Pin 85 - Pin 86)
K70 20 A (Pin 30 - Pin 87a)
40 A (Pin 30 - Pin 87)
M6 Engine 12 - 15 A Short-circuit current
2-4A Working current
19a-2 Me-e-19a 09/06
TIC MEDION Electric system
Description of function:
Reel speed adjustment The reel speed adjustment electric motor (M6) rotates clockwise or
circuit counterclockwise by means of the reel speed adjustment switch (S24)
and relay K69 or K70. Speed adjustments are only allowed while the
reel is rotating.
Important! The earth supply at switch S24 depends on relay
K78 – Front attachment ON (diagram 17).
09/06 Me-e-19a 19a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector KNAge, PVBge Connector XP Socket XP
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
KNAge - 9 KNA 10 K69/30 1.5 gn/wh
KNAge - 10 KNA 9 K69/30 1.5 gn/wh
KNAge - 11 K70/30 KNA 12 1.5 gn/ye
KNAge -12 K70/30 KNA 11 1.5 gn/ye
PVBge - 1 PHA 13 K78/87 BLA 18 MOA 3 0.75 br/ye
PVBge - 2 K70/85 0.75 vi/rt
PVBge - 3 K69/85 0.75 vi/bk
XP - 31 2.5 gn/wh
XP - 58L 2.5 gn/ye
19a-4 Me-e-19a 09/06
19b
Rake-up
Speed adjustment, hydraulic oil temperature monitoring
Electric system MEDION TIC
19b Rake-up - Speed adjustment, hydraulic oil temperature monitoring
Key to diagram: Coordinates
A8 AUTOCONTOUR module...................................................4-g-17
H11 Hydraulic oil temperature signal light...................................6-f-16
K69 Reel speed adjustment relay ..............................................4-g-17
K70 Reel speed adjustment relay ..............................................4-g-17
K78 Front attachment identification relay...................................4-g-17
M33 Motorized flow controller (MFC) ..........................................6-f-16
S24 Reel speed adjustment switch............................................4-g-17
S52 Road travel switch (red)......................................................4-g-17
Z20 Hydraulic oil temperature actual value switch .....................6-f-16
Measured value table: Item Component Measured Remark
value
K69 Remote control relay 85±7 Ω (Pin 85 - Pin 86)
K70 20 A (Pin 30 - Pin 87a)
40 A (Pin 30 - Pin 87)
M33 Motor 500 mA Maximum current
(see lettering)
Z20 Switch 104±3°C NO contact
19b-2 Me-e-19b 06/07
TIC MEDION Electric system
Description of function:
Rake-up speed adjustment The reel speed adjustment switch (S24) and relay K69 or K70 turn the
circuit motorized flow controller (MFC) electric motor (M33) to one or the other
direction. The flow rate can be adjusted only with the rake-up running.
Important: The earth supply at switch S24 depends on relay
K78 – Front attachment On (diagram 17).
Hydraulic oil temperature The hydraulic oil temperature actual value switch (Z20) activates the
warning (overtemperature) hydraulic oil temperature signal light (H11) of the rake-up at an oil
temperature of > 104±3°C.
06/07 Me-e-19b 19b-3
Electric system MEDION TIC
Connector pin
assignment:
Connector KNAge, PVBge Connector XL, XP Socket XL, XP
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
KNAge - 9 KNA 10 K69/30 1.5 gn/wh
KNAge - 10 KNA 9 K69/30 1.5 gn/wh
KNAge - 11 K70/30 KNA 12 1.5 gn/ye
KNAge -12 K70/30 KNA 11 1.5 gn/ye
PVBge - 1 PHA 13 K78/87 BLA 18 MOA 3 0.75 br/ye
PVBge - 2 K70/85 0.75 vi/rt
PVBge - 3 K69/85 0.75 vi/bk
XL - 31 0.75 br/wh
XL - 54g 0.75 bl/gn
XP - 31 2.5 gn/wh
XP - 58L 2.5 gn/ye
19b-4 Me-e-19b 06/07
20a
Raise/lower front attachment,
transverse control
Electric system MEDION TIC
20a Raise/lower front attachment, transverse control
Key to diagram: Coordinates
A8 AUTOCONTOUR module (CAC) ........................................ 4-g-17
A52 Multi-function handle module (MFG) .................................. 4-g-17
DO Master valve diode PCB...................................................... 4-g-17
K60 Road travel release relay .................................................... 4-g-17
S46 Cutterbar transverse control switch (manual) ..................... 4-g-17
S52 Road travel switch (red) ...................................................... 4-g-17
S56 Raise front attachment switch ............................................. 3-g-18
S66 Lower front attachment switch............................................. 3-g-18
Y67 Solenoid coil
AUTOCONTOUR transverse control left............................. 5-h-16
Y68 Solenoid coil
AUTOCONTOUR transverse control right........................... 5-h-16
Y85 Raise front attachment solenoid coil ................................... 5-h-16
Y87 Lower front attachment solenoid coil................................... 5-h-16
Measured value table: Item Component Measured Remark
value
Y67 Solenoid coil 3.8 A See lettering
Y68 3.2 Ω
Y85
Y87
20a-2 Me-e-20a 09/06
TIC MEDION Electric system
Description of function:
Raise/lower front Depending on the actuation of the raise/lower front attachment
attachment (manual) pushbuttons (S56 / S66), the corresponding solenoid coils (Y87 / Y85) are
actuated via the multi-function handle module (A52) – the front
attachment is raised or lowered.
The master valve (Y77) is also actuated via the diode PCB (DO) in
parallel with the front attachment raise function (Y85) because this
function requires that pressure is built up in the system.
Transverse control (manual) Voltage is applied to the solenoid coils Y67/Y68 as a function of the road
circuit travel switch S52. After actuation of switch S46, the required earth is
connected either to solenoid coil Y67 or Y68.
The master valve (Y77) is also actuated via the diode PCB (DO) in
parallel with the solenoid coils (Y67, Y68) because this function requires
that pressure is built up in the system.
09/06 Me-e-20a 20a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector Connector Connector
HDAge, MFAgn, MFBgr MFG PVCge
Socket
Y67, Y68, Y85, Y87
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
HDAge - 1 ASA 3 a17a VSA 1 1.5 sw/vi
HDAge - 2 CAC 12 MFA 3 DI 5 KNA 15 DO 6 1.5 br/bk
HDAge - 3 CAC 11 MFA 4 DI 6 KNA 16 1.5 br/rd
HDAge - 12 PHA 7 PVC 9 K60/86 CAC 1 CAC 14 1.5 bk/bl
K56/86 KNB 2
HDAge - 13 PVC 11 CAC 10 DO 7 1.5 br/gn
HDAge - 14 PVC 10 CAC 3 DO 8 1.5 br/bl
PVCge - 12 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.0 br
LSA 1 LSB 10 LSB 4 PVC 12 CAC 8
CAC 17 HDA 8 AP 8 AP 9 KBB 6
KBB 8 K60/85 MOB 2 KBA 17 K64/85
VSA 4 DO 22 FSA 1 FSA 5 APA 8
MOA 2 HKA 19 PHA 2 KNA 2 K49/85
K79/30 K57/31 K61/85 K52/85 K53/85
K50/85 K66/85 K69/87a K70/87a K71/87a
K72/87a K75/85 K77/85 BFA 3 ASA 1
KBA 5 KBB 12 KBA 9 KBA 10 K54/85
ZGA 3 ZGA 4 BFA 2
20a-4 Me-e-20a 09/06
21a
Reel adjustment
- Folding the maize picker /
snapping plate adjustment see 21b
Electric system MEDION TIC
21a Reel adjustment
Key to diagram: Coordinates
A52 Multi-function handle module (MFG) ....................................4-g-17
DO Master valve diode PCB ........................................................4-g-17
E35 Instrument lighting..................................................................4-g-17
K60 Road travel release relay .......................................................4-g-17
S19 Raise reel switch....................................................................3-g-18
S20 Lower reel switch ...................................................................3-g-18
S21 Reel forward switch................................................................3-g-18
S22 Reel backward switch ............................................................3-g-18
S34 Maize cutterbar fold switch (option) .......................................4-g-17
U10 Switch (external)
Fold cutterbar to transport position ........................................5-g-17
U9 Switch (external)
Fold cutterbar to working position..........................................5-g-17
Y22 Reel raise solenoid coil ..........................................................5-h-16
Y23 Reel lower solenoid coil .........................................................5-h-16
Y24 Reel forward solenoid coil......................................................5-h-16
Y25 Reel backward solenoid coil ..................................................5-h-16
Measured value table: Item Component Measured Remark
value
Y22 Solenoid coil 3.8 A See lettering
Y23 3.2 Ω
Y24
Y25
21a-2 Me-e-21a 09/06
TIC MEDION Electric system
Description of function:
Reel raise/lower circuit When the „Reel raise/lower function“ is activated, the corresponding
solenoid coils Y22 / Y23 are energized directly by switches S19 / S20 via
the multi-function handle module A52.
The master valve (Y77) is also actuated via the diode PCB (DO) in
parallel with solenoid coil (Y22) because this function requires that
pressure is built up in the system.
Reel forward/backward In the reel forward/backward function, the corresponding solenoid coils
circuit Y24 / Y25 are actuated directly by switches S21 / S22.
The master valve (Y77) is also actuated via the diode PCB (DO) in
parallel with solenoid coils (Y24, Y25) because this function requires that
pressure is built up in the system.
Folding the maize picker When the „Fold maize picker to working position“ function is activated, the
to working position corresponding solenoid coil Y25 is energized directly by the fold maize
header switch (S34).
The master valve (Y77) is also actuated via the diode PCB (DO) in
parallel with solenoid coil (Y25) because this function requires that
pressure is built up in the system.
The fold maize header switch (S34) must be actuated for another
6 seconds after the folding procedure in order to pressurise the system
hydraulically.
Folding the maize picker When the “Fold maize picker to transport position” function is activated,
to transport position the corresponding solenoid coil Y24 is energized directly by the fold maize
header switch (S34).
The master valve (Y77) is also actuated via the diode PCB (DO) in
parallel with solenoid coil (Y24) because this function requires that
pressure is built up in the system.
In addition, solenoid coil Y23 must be energized via the fold maize header
switch (S34) in order to perform this function.
Snapping plate adjustment When the “Snapping plate adjustment” function is activated, the
corresponding solenoid coils Y25 / Y25 are energized directly by the reel
forward / reverse switches S21 / S22 via the multi-function handle module
A52. The master valve (Y77) is also actuated via the diode PCB (DO) in
parallel with solenoid coils (Y24, Y25) because this function requires that
pressure is built up in the system.
09/06 Me-e-21a 21a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector Connector Connector
HDAge, MFAgn, MFBgr MFG VSAbl
Socket
Y22, Y23, Y24, Y25
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
HDAge - 4 MFA 5 DO 3 1.5 ye
HDAge - 5 MFA 6 VSA5 1.5 ye/rd
HDAge - 6 MFA 7 VSA 2 DO 4 1.5 pi
HDAge - 7 HDA 7 MFA 8 VSA 3 DO 5 1.5 gn/rd
HDAge - 9 MFA 1 a2a DO 1 1.5 bk/gn
MFBgr - 1 EARTH PVA 21 PVB 6 MFB 1 MFB 2 0.75 br
MFBgr - 2 LSA 1 LSB 10 LSB 4 PVC 12 CAC 8 0.75 br
CAC 17 HDA 8 AP 8 AP 9 KBB 6
KBB 8 K60/85 MOB 2 KBA 17 K64/85
VSA 4 DO 22 FSA 1 FSA 5 APA 8
MOA 2 HKA 19 PHA 2 KNA 2 K49/85
K79/30 K57/31 K61/85 K52/85 K53/85
K50/85 K66/85 K69/87a K70/87a K71/87a
K72/87a K75/85 K77/85 BFA 3 ASA 1
KBA 5 KBB 12 KBA 9 KBA 10 K54/85
ZGA 3 ZGA 4 BFA 2
21a-4 Me-e-21a 09/06
23a
Folding the cutterbar
Electric system MEDION TIC
23a Folding the cutterbar
Key to diagram: Coordinates
U9 Switch (external)
Fold cutterbar to working position..........................................5-g-17
U10 Switch (external)
Fold cutterbar to transport position ........................................5-g-17
U11 Switch (external)
Cutterbar fold reversing valve ................................................5-g-17
Y92 Solenoid coil
Cutterbar fold reversing valve ...............................................7-e-18
Z7 Reel bottom end position actual value switch........................7-d-10
Z14 Reel rear end position actual value switch ............................7-e-10
Z55 Cutterbar locked actual value switch .....................................7-e-17
Measured value table: Item Component Measured Remark
value
Y92 Solenoid coil 4.5 A
2.7 Ω
23a-2 Me-e-23a 09/06
TIC MEDION Electric system
Description of function:
Folding the cutterbar When using a folding cutterbar, the external switches U9/U10 are parallel with
the reel forward/backward switches (S21/S22) - (diagram 21a).
When folding to transport position, the solenoid coil Y92 for the cutterbar fold
reversing valve must additionally be actuated by the external switch U 11. As
a pre-condition for this, the switches Z7, Z14 and Z55 must be closed.
09/06 Me-e-23a 23a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector VSAbl Connector XA Socket XA
Socket Y 92
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
VSAbl - 1 ASA 3 HDA 1 a17a VSA 1 1.5 bk/vi
VSAbl - 4 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.5 br
LSA 1 LSB 10 LSB 4 PVC 12 CAC 8
CAC 17 HDA 8 AP 8 AP 9 KBB 6
KBB 8 K60/85 MOB 2 KBA 17 K64/85
VSA 4 DO 22 FSA 1 FSA 5 APA 8
MOA 2 HKA 19 PHA 2 KNA 2 K49/85
K79/30 K57/31 K61/85 K52/85 K53/85
K50/85 K66/85 K69/87a K70/87a K71/87a
K72/87a K75/85 K77/85 BFA 3 ASA 1
KBA 5 KBB 12 KBA 9 KBA 10 K54/85
ZGA 3 ZGA 4 BFA 2
23a-4 Me-e-23a 09/06
24a
AUTOCONTOUR (CAC)
- Contour see 24b
Electric system MEDION TIC
24a AUTOCONTOUR (CAC)
Key to diagram: Coordinates
A8 AUTOCONTOUR module (CAC)...........................................4-g-17
A52 Multi-function handle module (MFG) .....................................4-g-17
B3 AUTOCONTOUR sensor
Left sensing band (actual value)............................................9-d-26
B4 AUTOCONTOUR sensor
Right sensing band (actual value) .........................................9-d-10
H37 Cutting height control signal light...........................................4-g-17
H38 Pre-set cutting height control signal light ...............................4-g-17
K60 Road travel release relay .......................................................4-g-17
P9 Cutterbar spring pre-stress indicator .....................................4-g-17
P11 Pre-set cutting height control indicator ..................................4-g-17
R1 AUTOCONTOUR potentiometer
Left sensing band (actual value)............................................9-d-26
R2 AUTOCONTOUR potentiometer
Right sensing band (actual value) .........................................9-d-10
R8 Potentiometer
Feeder housing position (actual value)..................................6-h-17
R22 Potentiometer
Cutterbar spring pre-stress (actual value) .............................7-h-17
R23 Potentiometer
Cutting height control (set value) ...........................................4-g-17
R24 Potentiometer
Pre-set cutting height control (set value) ...............................4-g-17
S11 CAC main switch....................................................................4-g-17
S12 Cutting height control /
Automatic ground pressure control (CAC) switch..................5-h-16
S13 Pre-set cutting height control (CAC) switch ...........................5-h-16
S25 Main drive switch (threshing mechanism clutch) ...................3-h-17
S52 Road travel switch (red) .........................................................4-h-17
Notes: A- when potentiometers (5 volt system) are fitted
B- when Hall sensors (12 volt system) are fitted
Measured value table: Item Component Measured value Remark
B3 Sensor 12 V (Pin 1 - 2)
B4 0.25 V - 4.75 V (Pin 1 - 3)
R1 Potentiometer 4.25 kΩ (Pin 1 - 3) coil
R2 1.50 - 5.75 kΩ (Pin 2 - 1/3) slider
R8 Potentiometer 10 - 190 Ω
R22
R23 Potentiometer 0 - 22 kΩ
R24
24a-2 Me-e-24a 09/06
TIC MEDION Electric system
Description of function: 1/2
AUTO-CONTOUR
function AUTO-CONTOUR (CAC) includes the functions cutting height control
and/or pre-set cutting height control.
The AUTOCONTOUR (CAC) module A8 is activated by actuating switch
S11.
Important! On machines with AUTO-CONTOUR, a module with the
corresponding spare part no. must be used which is
different from the CONTOUR system.
Cutting height control The function "Cutting height control" is activated by actuating switch S12
in the module CAC A8.
In the cutting height control, both the sensors B3/B4 and/or potentiometer
R1/R2 of the sensing bands on the cutterbar and the cutterbar spring pre-
stress potentiometer R22 are active as actual values. The set value is
defined by potentiometer R23.
Changes of the signal values are detected by module A8. Now the
relevant solenoid coils of the individual functions (transverse control
right/left and/or front attachment raise/lower) are actuated by module A8
until the set values and the actual values of the corresponding sensors /
potentiometers are identical.
Pre-set cutting height The function "Pre-set cutting height control" is activated by actuating
control switch S13 in the module CAC A8.
When this function is selected, there is no active cutting height control.
The signal values of the feeder housing position (R8 – actual value) and
pre-set cutting height control (R24 – set value) potentiometers are made
identical by the relevant solenoid coils (raise/lower front attachment).
Emergency clearance In the function "Pre-set cutting height control", the front attachment makes
way by means of the transverse control as soon as a sensing band has
ground contact (e.g. an obstacle). The front attachment must now be
returned manually.
09/06 Me-e-24a 24a-3
Electric system MEDION TIC
Description of function: 2/2
Learning the sensor values The AUTO-CONTOUR module (A8) must be set to the programming
mode for learning the sensor values and for programming the AUTO-
CONTOUR control response. This is done using the CAC main switch
(S11).
Learning is necessary after replacing the AUTO-CONTOUR module (A8)
or the sensors / potentiometers of the AUTO-CONTOUR system.
Calling up the programming - Engage the threshing mechanism and the front attachment.
mode - Set the cutting height control potentiometer (R23) to the value
Learning the sensor values desired for the AUTO-CONTOUR control response.
Programming the AUTO– - Keep the CAC main switch (S11) pressed for 3 seconds beyond the
CONTOUR control notch. Now the indicator lights H37 and H38 flash.
response At the same time, the raise/lower front attachment solenoid coils
(Y85/Y87) are energized by the multi-function handle module (A52).
- Actuate the attachment completely until the cutterbar cylinder
springs have been relieved. Keep the lower front attachment switch
(S66) pressed in this position for another 30 seconds.
- Actuate the raise front attachment switch (S56). Raise the front
attachment completely. Keep the raise front attachment switch (S56)
pressed in this position for another 30 seconds.
Programming values for Position = 5 = Default value
AUTO–CONTOUR control
response by R23 Position < 5 = More influence by cutterbar spring pre-tension
potentiometer R22 (down grain, soft ground).
Position > 5 = More influence of sensor band sensors and/or
potentiometers R1/R2 and B3/B4.
Position > 8 = Recommended for use with soybean cutterbars
24a-4 Me-e-24a 09/06
TIC MEDION Electric system
Connector pin
assignment:
Connector Connector Connector
PVBge, PVCge, KNBge MFAgn, MFBgr MFG
Connector XL Socket XL
09/06 Me-e-24a 24a-5
Electric system MEDION TIC
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
CCws - 1 0.5 gr/bl
CCws - 10 0.5 bl/gn
CCws - 2 0.5 bl/rd
CCws - 3 0.5 bk/gn
CCws - 4 0.5 ye/gr
CCws - 8 0.5 br/wh
CCws - 9 0.5 gr/rd
KNBge - 2 PHA 7 HDA 12 PVC 9 K60/86 CAC 1 0.75 bl/gn
CAC 14 K56/86
KNBge - 3 PVC 4 0.5 bl/wh
KNBge - 4 PVC 5 CAC 19 0.5 bl/gr
KNBge - 5 CAC 23 0.5 bl/bk
KNBge - 6 CAC 22 0.75 wh/bl
KNBge - 7 CAC 22 0.75 bk/bl
KNBge - 8 PVC 18 CAC 20 0.75 bk/gn
KNBge - 9 PVC 15 CAC 16 0.75 br/wh
MFAgn - 1 HDA 9 a2a DO 1 0.75 bk
MFBgr -1 EARTH PVA 21 PVB 6 MFB 1 MFB 2 0.75 br
MFBgr -2 LSA 1 LSB 10 LSB 4 PVC 12 CAC 8 0.75 br
CAC 17 HDA 8 AP 8 AP 9 KBB 6
KBB 8 K60/85 MOB 2 KBA 17 K64/85
VSA 4 DO 22 FSA 1 FSA 5 APA 8
MOA 2 HKA 19 PHA 2 KNA 2 K49/85
K79/30 K57/31 K61/85 K52/85 K53/85
K50/85 K66/85 K69/87a K70/87a K71/87a
K72/87a K75/85 K77/85 BFA 3 ASA 1
KBA 5 KBB 12 KBA 9 KBA 10 K54/85
ZGA 3 ZGA 4 BFA 2
MFBgr - 3 K55/30 PVC 20 CAC 13 0.75 ye
MFBgr - 4 K55/85 DI 8 CAC 15 0.75 ye/br
MFBgr - 5 CAC 2 0.75 rd/ye
MFBgr - 11 PVC 7 0.75 wh/vi
24a-6 Me-e-24a 09/06
TIC MEDION Electric system
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
PVCge - 4 KNB 3 0.5 bl/wh
PVCge - 5 KNB 4 CAC 19 0.5 bl/gr
PVCge - 9 PHA 7 HDA 12 K60/86 CAC 1 CAC 14 1 bl/gn
K56/86 KNB 2
PVCge - 13 CAC 6 0.5 gr/rd
PVCge - 14 CAC 25 0.5 ye/gr
PVCge - 15 CAC 16 KNB 9 0.5 gr/bl
PVCge - 16 CAC 5 0.5 br/wh
PVCge - 17 CAC 24 0.5 bl/rd
PVCge - 18 CAC 20 KNB 8 0.5 bk/gn
PVCge - 20 K55/30 MFA 4 CAC 13 1.5 ye/bk
PVCge - 21 PHA 11 1.5 bk/ye
XL - 31 0.75 br/wh
XL - 54 0.75 bk/gn
XL - 54g 0.75 bl/gn
XL - 58L 0.75 wh/bk
XL - L 0.75 bk/bl
09/06 Me-e-24a 24a-7
Electric system MEDION TIC
24a-8 Me-e-24a 09/06
24b
Contour
- AUTOCONTOUR (CAC) see 24a
Electric system MEDION TIC
24b CONTOUR
Key to diagram: Coordinates
A8 AUTOCONTOUR module (CAC)...........................................4-g-17
A52 Multi-function handle module (MFG) .....................................4-g-17
DI Diode PCB .............................................................................4-g-17
K55 Contour circuit relay ...............................................................4-g-17
K60 Road travel release relay .......................................................4-g-17
S11 Contour main switch ..............................................................4-g-17
S12 Cutting height control switch /
Automatic ground pressure control .......................................3-g-18
S13 Pre-set cutting height control switch .....................................3-g-18
S25 Main drive switch (threshing mechanism clutch) ...................3-h-17
S52 Road travel switch (red) .........................................................4-h-17
V16 Amplifier .................................................................................7-h-19
Y85 Raise front attachment solenoid coil......................................5-h-16
Y87 Lower front attachment solenoid coil .....................................5-h-16
Z73 Automatic ground pressure control actual value switch ........7-h-19
Measured value table: Item Component Measured Remark
value
K55 Remote control relay 95±10 Ω (Pin 85 - Pin 86)
15 A (Pin 30 - Pin 87a)
30 A (Pin 30 - Pin 87)
24b-2 Me-e-24b 09/06
TIC MEDION Electric system
lDescription of function:
CONTOUR function The CONTOUR system includes the functions automatic ground pressure
control and pre-set cutting height control. The automatic ground pressure
control is controlled by relay K55 and the pre-set cutting height control by
the Contour module A8.
Automatic ground pressure When relay K55 connects earth from pin 87 to switch Z73 (ground
control pressure), the cutterbar can be raised or lowered automatically,
depending on the outside conditions.
- ON After actuating the main switch S11, earth is applied to pin 30 of relay K55
when the threshing mechanism is engaged. Voltage is applied to pin 86 of
relay K55 (see diagram 20a) via the unactivated solenoid coils Y85/Y87
and via the diode PCB DI.
When pushbutton S12 is actuated, earth is applied to pin 85 of relay K55
via the multi-function handle module (A52).
At the same time, the necessary earth is applied at the automatic ground
pressure control switch Z73. Switch Z73 is coupled to the left-hand
cutterbar spring. When the spring length changes, the earth applied to
switch Z73 is connected to the corresponding solenoid valves Y85 or Y87.
The cutterbar is raised or lowered (see diagram 20a).
- OFF Deactivating the CONTOUR function is possible in several ways.
- Open switch S11; K55 drops out - Contour is deactivated.
- Raise or lower the cutterbar manually; the corresponding solenoid
coils Y85 or Y87 are actuated directly by S56 and/or S66, the
cutterbar is raised or lowered. This changes the length of the
cutterbar spring, switch Z73 connects earth to the other solenoid coil
(Y87 or Y85). Both solenoid coils are actuated for a short period, the
locking-in of K55 is stopped, K55 drops out – CONTOUR is
deactivated.
Pre-set cutting height The "Pre-set cutting height control" function is activated by actuating
control switch S13 in Contour module A8 via the multi-function handle module
(A52).
The signal values of the feeder housing position (R8 – actual value) and
pre-set cutting height control (R24 – set value) potentiometers are made
identical by the relevant solenoid coils (raise/lower front attachment).
Important! On machines with CONTOUR system, a module with the
corresponding spare part number must be used that is
different from the AUTO-CONTOUR system. In case of
machines with CONTOUR system, potentiometer R 23 in the
operating panel exists, but has no function. An existing
potentiometer
R 22 on the cutterbar spring serves merely for indicating the
spring pre-stress in the panel.
09/06 Me-e-24b 24b-3
Electric system MEDION TIC
Connector pin
assignment:
Connector Connector Connector
KNAge, PVCge, MFAgn, MFBgr MFG
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
KNAge - 14 K55/87 DI 9 1.5 bl/gn
KNAge - 15 CAC 12 MFA 7 DI 5 HDA 2 0.75 br/bk
KNAge - 16 CAC 11 MFA 8 DI 6 HDA 3 0.75 br/rd
MFAgn - 1 HDA 9 a2a DO 1 0.75 bk
MFBgr - 1 EARTH PVA 21 PVB 6 MFB 1 MFB 2 0.75 br
MFBgr - 2 LSA 1 LSB 10 LSB 4 PVC 12 CAC 8 0.75 br
CAC 17 HDA 8 AP 8 AP 9 KBB 6
KBB 8 K60/85 MOB 2 KBA 17 K64/85
VSA 4 DO 22 FSA 1 FSA 5 APA 8
MOA 2 HKA 19 PHA 2 KNA 2 K49/85
K79/30 K57/31 K61/85 K52/85 K53/85
K50/85 K66/85 K69/87a K70/87a K71/87a
K72/87a K75/85 K77/85 BFA 3 ASA 1
KBA 5 KBB 12 KBA 9 KBA 10 K54/85
ZGA 3 ZGA 4 BFA 2
MFBgr - 3 K55/30 PVC 20 CAC 13 0.75 ye
MFBgr - 4 K55/85 DI 8 CAC 15 0.75 ye/br
MFBgr - 5 CAC 2 0.75 rd/ye
MFBgr - 11 PVC 7 0.75 wh/vi
PVCge - 7 MFB 11 PVC 7 1.0 wh/vi
PVCge - 9 PHA 7 HDA 12 K60/86 CAC 1 CAC 14 1.0 bl/gn
K56/86 KNB 2
PVCge - 20 K55/30 MFA 4 CAC 13 1.5 ye/bk
PVCge - 21 PHA 11 1.5 bk/ye
24b-4 Me-e-24b 09/06
25a
Speed monitoring
Electric system MEDION TIC
25a Speed monitoring
Key to diagram: Coordinates
A12 Speed monitor module (DZW) ...............................................4-g-17
B10 Diesel engine speed sensor...................................................4-j-19
B12 Feeder housing speed sensor ...............................................6-h-16
B21 Grain elevator speed sensor..................................................2-m-16
B26 Straw walker speed sensor....................................................4-m-16
B28 Straw chopper speed sensor .................................................6-t-20
B29 Returns speed sensor............................................................4-i-16
DI Diode PCB .............................................................................4-g-17
H4 Threshing mechanism STOP signal light...............................4-g-17
H27 Feeder housing slip / standstill signal light ............................4-g-17
H32 Grain elevator slip / standstill signal light...............................4-g-17
H34 Straw chopper slip / standstill signal light ..............................4-g-17
H35 Straw walker slip / standstill signal light.................................4-g-17
H36 Returns elevator slip / standstill signal light ...........................4-g-17
K79 Front attachment identification relay......................................4-g-17
Z59 Straw chopper baffle plate position actual value switch ........6-t-20
Measured value table: Item Component Measured Remark
value
B10 Sensor 1000-1200 Ω inductive
B12
B21
B26
B28
B29
25a-2 Me-e-25a 09/06
TIC MEDION Electric system
Description of function:
Speed monitoring The frequencies of the individual sensors are processed by the speed
monitoring module A12. If the allowed slip values are exceeded, the module
activates the corresponding signal lights and the buzzer as an acoustic
warning. Relay K77 passes the alarm messages on to the warning buzzer
(H44) (see diagram 3).
Important! The chopper speed monitoring is active only if switch Z59 is
closed (straw chopper in working position).
SET speeds Min. speeds
rpm rpm
Straw walker 220 174
Returns elevator 308 230
Grain elevator
MEDION 310-330 380 260
MEDION 340 450 260
Feed rake 520 385
Straw chopper
2 cams 3300 2820
4 cams 1920 1410
09/06 Me-e-25a 25a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector HKBbl, KNAge, Connector LSAgr
LSBgr, PVBge, PVCge
Connector WS II Socket WS II
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
HKBbl - 2 DZW 16 0.75 gn/or
HKBbl - 3 DZW 3 K79/87 0.75 br/ye
HKBbl - 4 DZW 21 0.75 gn/br
HKBbl - 5 DZW 2 0.75 gn/bl
HKBbl - 6 DZW 11 0.75 gn/wh
HKBbl - 7 DZW 25 0.75 gn/bk
KNAge - 7 DZW 10 0.75 gn/wh
LSAgr - 12 DI 3 DZW 14 0.5 or
PVBge - 18 DI 1 0.5 bk/wh
PVBge - 19 DZW 9 0.5 wh/bk
PVBge - 20 DZW 12 0.5 wh/gn
PVCge - 1 DZW 1 0.5 wh
PVCge - 2 DZW 4 0.5 wh/rd
PVCge - 3 DZW 13 0.5 wh/bk
WS II - 5 1.5 bk
WS II - 10 0.5 or
25a-4 Me-e-25a 09/06
26a
Machine monitoring
Electric system MEDION TIC
26a Machine monitoring
Key to diagram: Coordinates
DI Diode PCB .............................................................................4-g-17
H8 Parking brake activated signal light .......................................3-g-18
H25 Reversing horn.......................................................................4-o-16
H39 Sieve pan / left steering position signal light..........................3-g-18
H40 Sieve pan / right steering position signal light .......................3-g-18
H43 Straw jam signal light .............................................................4-g-17
H55 Min. hydraulic oil level signal light..........................................3-g-18
P7 Fuel tank level display............................................................3-g-18
R35 Fuel level potentiometer.........................................................4-p-16
Z9 Brake lining wear actual value switch ....................................7-i-18
Z12 Parking brake actual value switch .........................................5-h-17
Z19 Min. hydraulic oil level actual value switch ............................3-i-19
Z38 Left steering position actual value switch ..............................7-q-19
Z39 Right steering position actual value switch ............................7-q-17
Z50 Ground speed control lever backward /
reversing horn actual value switch.........................................4-g-17
Z61 Straw jam warning actual value switch ..................................3-g-18
Measured value table: Item Component Measured value Remark
R35 Potentiometer 10 - 190 Ω
26a-2 Me-e-26a 09/06
TIC MEDION Electric system
Description of function:
Straw jam warning When a straw jam occurs in the straw walker house, pushbutton Z61
closes.
In this case, the signal lights H4 and H43 light up permanently.
At the same time, the warning buzzer relay K77 activates
- the buzzer (pulse buzzer) H 44,
- the warning lights H 42 in the operations display screen and
- warning light H 45 on the vehicle information unit permanently
(see diagrams 3 and 25).
Hydraulic oil level warning When the hydraulic oil level is low, the hydraulic oil level min. actual value
switch (Z19) closes. The hydraulic oil level min. indicator light (H55) lights
up.
09/06 Me-e-26a 26a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector FSAgr Connector HKAbl, Connector LSAgr
KNAge, LSBgr, PVBge
Connector RT1, WS II Socket RT1, WS II
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
FSAgr - 1 EARTH PVA 21 PVB 6 MFB 1 MFB 2 0.75 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 BFA 2
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12
FSAgr - 2 LSA 6 KNA 8 0.75 br/wh
HKAbl - 7 LSB 9 0.75 bl/gr
HKAbl - 8 LSA 10 0.75 bl/or
HKAbl - 9 PVB 9 DI 2 0.75 wh/gn
HKAbl - 10 PHA 3 PVA 20 b6a BLA 14 KBA4 0.75 bk
HKAbl - 11 LSB 12 0.75 bl/bk
KNAge - 8 LSA 6 FSA 2 0.75 br/wh
LSAgr - 6 KNA 8 FSA 2 0.75 br/wh
LSAgr - 7 b2a 1.5 bk
LSAgr - 10 HKA 8 0.75 bl/or
26a-4 Me-e-26a 09/06
TIC MEDION Electric system
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
LSBgr - 7 MOB 20 DI 20 0.75 wh/ye
LSBgr - 9 HKA 7 0.75 bl/gr
LSBgr - 10 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.5 br
BFA 2 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12
LSBgr - 12 HKA 11 0.75 bl/bk
MOBbr - 20 LSB 7 DI 20 0.75 wh/ye
PVBge - 7 a9a 0.5 bk
PVBge - 9 DI 2 HKA 9 0.75 wh/gn
PVBge -20 DZW 12 0.5 wh/gn
RT1 - 9 0.75 bl/gr
RT1 - 10 1.5 br
RT1 - 12 0.75 bl/bk
WS II - 4 0.75 br/wh
WS II - 5 1.5 bk
WS II - 8 0.75 bl/or
09/06 Me-e-26a 26a-5
Electric system MEDION TIC
26a-6 Me-e-26a 09/06
27a
Yield meter
- optional variant (Agrocom)
Electric system MEDION TIC
27a Yield meter
Key to diagram: Coordinates
A10 Fieldwork computer module (BIF/CAB) .................................4-g-17
A21 YIELD METER module (LEM) ...............................................4-j-16
A30 ACT terminal (no display, connected to connector XB)
B10 Diesel engine speed sensor...................................................5-i-20
B11 Threshing drum speed sensor ...............................................5-j-19
B15 Fan speed sensor ..................................................................7-m-16
B16a Transmission speed sensor (ground speed) .........................7-i-16
B59 YIELD METER (LEM) receiver sensor ..................................4-n-16
B60 YIELD METER (LEM) transmitter sensor ..............................4-n-16
B61 YIELD METER grain humidity sensor....................................2-n-17
B62 YIELD METER inclination sensor ..........................................7-i-18
R Resistor (CAN matching resistor) ..........................................4-g-17
XB Connecting plug for cabling of terminal A30
(docking station).....................................................................4-g-17
XD Connecting plug of wiring looms (cab – machine) .................4-j-16
XE Connector for CAN terminal resistor (relay socket) ...............4-g-17
XG Additional connector ..............................................................4-g-17
Z71 Front attachment working position actual value switch .........5-g-17
Measured value table: Item Component Measured Remark
value
B10 Sensor 1000 - 1200 Ω inductive
B11
B15
B16a Sensor I-0 Reed contact
B59 Receiver > 2.5 V with light incidence
~ 1.2 V with shading
B60 Transmitter 12 V Transmits infrared light
B61 Humidity sensor 7V Reference voltage
(pin 4)
B62 Inclination sensor 30° - 0° - 30° Conductive liquid
1.2 - 3.0 - 4.8 V
27a-2 Me-e-27a 09/06
TIC MEDION Electric system
Description of function:
Yield measuring The yield measuring is based on flow rate measurement by the light
barrier (B59/B60) inside the grain elevator, depending on transverse and
longitudinal inclination of the machine. Based on these signals, the yield
meter module (A21) calculates the yield and displays this information in
terminal A30 via the CAN bus.
System calibration by entering the litre weight and by checking the values
by counterweighing a defined grain quantity constitute important
fundamentals for a precise calculation.
Humidity measurement The measurements made by the humidity sensor (B61) are also displayed
by the yield meter module (A21) in terminal A30 via the CAN bus, but are
not used for calculating the gross weight.
Terminal A30 requires these measured values for calculation only for
stating the net weight in order processing.
Fieldwork computer The signals from sensors B10, B11, B15 and B16a are entered into the
functions fieldwork computer module (BIF/CAB) A10 and processed there. This
module transmits the established information data to terminal A30 via the
CAN bus.
09/06 Me-e-27a 27a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector BFAgr Connector KBAgn
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
BFAgr - 1 KBA3 b18a 0.5 bk
BFAgr - 3 EARTH PVA 21 PVB 6 MFA 1 MFA 2 0.5 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA17 MOA 2 HKA 19 PHA 2 FSA 1
APA 8 K57/31 K61/85 K52/85 KNA 2
K79/30 K69/87a K70/87a K71/87a K53/85
K66/85 K77/85 BFA 3 ASA 1 K72/87a
K75/85 KBA10 K54/85 ZGA 3 KBA5
KBA9 LSA 1 HDA 8 MOB 2 ZGA 4
FSA 5 K49/85 K50/85 K73/31 KBB 12
BFA 2
BFAgr - 4 DZW 5 MOB 14 0.5 rd/ye
BFAgr - 6 KNB 14 0.5 rd/bl
BFAgr - 7 PVA 15 MOB 1 KNB 12 0.75 bk/vi
BFAgr - 8 PVA 16 HKA 20 0.5 bl/wh
BFAgr - 9 PVB 15 KNB 13 0.5 rd/bk
27a-4 Me-e-27a 09/06
28a
AUTOPILOT
Electric system MEDION TIC
28a AUTOPILOT
Key to diagram: Coordinates
A9 AUTOPILOT module (ATP) ...................................................4-g-17
B6 AUTOPILOT wheel angle sensor .........................................8-q-19
B7 AUTOPILOT left touch sensor ...............................................8-b-17
B8 AUTOPILOT right touch sensor.............................................8-b-19
B83 AUTOPILOT OFF sensor (overrider switch)..........................5-g-18
H2 AUTOPILOT signal light.........................................................3-g-18
K63 Threshing mechanism relay...................................................4-g-17
R3 AUTOPILOT centralizing switch potentiometer (set value) ...4-g-17
S9 AUTOPILOT ON switch .........................................................5-g-17
S10 AUTOPILOT main switch.......................................................4-g-17
Y9 AUTOPILOT left solenoid coil ................................................5-h-17
Y10 AUTOPILOT right solenoid coil..............................................5-h-17
Y77 Circulation shut-off valve solenoid coil...................................5-h-16
Z4 AUTOPILOT oil pressure actual value switch........................5-h-17
Z5 Seat contact actual value switch ...........................................4-h-18
Measured value table: Item Component Measured Remark
value
B6
B7 Pushbutton (analogue) 5.0 V Power supply (Pin 31 - 54)
B8 2.25 V Straight ahead (Pin 58)
2.55 V Max. path (Pin 58)
2.85 V Min. path (Pin 58)
R3 Potentiometer 4.70 kΩ (Pin A - E) coil
1.7 - 6.4 kΩ (Pin S - E) slider
Y9 Solenoid coil 3.8 A
Y10 3.2 Ω
28a-2 Me-e-28a 09/06
TIC MEDION Electric system
Description of function:
AUTOPILOT function with With the road travel activation unlocked and the threshing mechanism
sensor system engaged, the AUTOPILOT module A 9 is supplied with power via main
switch S10. Following the start signal from foot switch S9, the solenoid
coils Y9/Y10 are actuated, depending on the signals from the touch
sensors B7/B8. The steering position is controlled by wheel angle sensor
B 6.
The master valve (Y77) is also actuated via the diode PCB (DO) in
parallel with the solenoid coils (Y9/Y10) because this function requires
that pressure is built up in the system.
For safety reasons, the AUTOPILOT function is interrupted immediately
by the signal from overrider switch Z3 when the steering wheel is turned
manually or after approx. 5 seconds after leaving the operator's seat, by
means of seat contact Z5.
The centralizing switch R3 allows setting precise straight forward travel
even when driving on slopes.
To allow quick steering reactions during AUTOPILOT operation, the
hydraulic system is equipped with an accumulator. If the pre-stress of this
accumulator drops to below approx. 135 bar, the oil pressure switch Z4
triggers the circulation shut-off valve Y77 until a charging pressure of
approx. 160 bar has again been reached.
Settings on the module
a - Steering signal right
b - Steering signal left
c - Malfunction indicator
d - Operation check
Potentiometers
1 - Steering angle: At maximum steering angle by the system sensors, the steering cylinder
stroke is set to 26-34 mm for both directions.
2 - Straight ahead travel: Setting of straight ahead travel when centralizing switch is in neutral
position.
3 - Response threshold: The sensitivity of steering reactions is adapted to calm the system.
* The potentiometers (1, 2, 3) are shown here in their basic position.
09/06 Me-e-28a 28a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector APAbl, LSAgr Connector HKBbl, KNAge, Connector FSAge
PVAge, PVBge
Connector B7, B8, XP Socket B7, B8, XP
28a-4 Me-e-28a 09/06
TIC MEDION Electric system
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
APAbl - 1 PVA 2 PVA 6 AP 1 AP 2 1.5 gn/rd
APAbl - 3 AP 11 AP 10 1.5 bk
APAbl - 4 AP 13 AP 12 1.5 bk/ge
APAbl - 5 AP 4 AP 3 1.5 yn
APAbl - 6 AP 15 0.75 bk/wh
APAbl - 7 AP 16 0.75 bk/vi
APAbl - 8 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.5 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12 BFA 2
FSAge - 1 EARTH PVA 21 PVB 6 MFB 1 MFB 2 0.75 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12 BFA 2
FSAgr - 3 PVA 3 AP 5 0.75 br/vi
HKBbl - 14 AP 18 0.75 rd/bk
HKBbl - 15 AP 14 0.75 rd/ye
HKBbl - 16 AP 17 0.75 rd/bl
KNAge - 3 AP 24 1 bk/gn
KNAge - 4 AP 21 1 bk/bl
KNAge - 5 AP 22 1 bk/rd
KNAge - 6 AP 25 1 bk/ye
09/06 Me-e-28a 28a-5
Electric system MEDION TIC
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
LSAgr - 5 AP 6 0.5 gr/bl
LSAgr - 7 b2a 1.5 bk
PVAge - 1 PHA 15 b10a MOA 1 K71/86 K72/86 1.5 bk/gr
PVAge - 2 PVA 6 AP 1 AP 2 APA 1 1.5 ye/bl
PVAge - 5 AP 23 0.5 rd
PVAge - 6 PVA 2 AP 1 AP 2 APA 1 0.5 ye/bl
PVBge - 6 EARTH PVA 21 PVB 6 MFB 1 MFB 2 0.75 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12 BFA 2
WS II - 3 0.5 gr/bl
WS II - 5 1.5 bk
XP - L 1.0 bk/gn
XP - R 1.0 bk/ye
XP - 54 1.0 bk/bl
XP - 54g 1.0 bk/rd
28a-6 Me-e-28a 09/06
29a
All-wheel drive
Electric system MEDION TIC
29a All-wheel drive
Key to diagram: Coordinates
S1 4-Trac (all-wheel drive) switch ...............................................4-g-17
Y1 4-Trac (all-wheel drive) solenoid coil .....................................8-p-18
H47 4-Trac (all-wheel drive) signal light ........................................3-g-18
Measured value table: Item Component Measured Remark
value
Y1 Solenoid coil 4.0 A
3.0 Ω
29a-2 Me-e-29a 09/06
TIC MEDION Electric system
Description of function: None
09/06 Me-e-29a 29a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector HKBbl, LSBgr, Connector LSAgr
PVAge
Connector RT1, WS II Socket RT1, WS II
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
HKBbl - 13 PVA 7 LSA 13 1.5 gn/rd
LSAgr - 13 PVA 7 HKB13 0.5 gn/rd
LSBgr - 10 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.5 br
BFA 2 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12
PVAge - 7 LSA 13 HKB13 1.5 gn/rd
PVAge - 20 PHA 3 KBA4 b6a BLA 14 HKA 10 1.5 bk
RT1 - 10 1.5 br
WS II - 11 0.5 gn/rd
29a-4 Me-e-29a 09/06
30a
Grain tank full indicator /
warning beacon
Electric system MEDION TIC
30a Grain tank full indicator / warning beacon
Key to diagram: Coordinates
DI Diode PCB .............................................................................4-g-17
E47 Warning beacon.....................................................................3-u-18
H16 Grain tank filling level 100% signal light ................................4-g-17
H17 Grain tank filling level 70% signal light ..................................4-g-17
K56 Warning beacon relay ............................................................4-g-17
K61 Generator release relay .........................................................4-g-17
K76 Grain tank full sensor relay ....................................................4-g-17
S40 Warning beacon switch..........................................................4-g-17
S52 Road travel switch (red) .........................................................4-g-17
S63 Warning tone delete switch....................................................4-g-17
Z27 Grain tank 100% full indicator................................................4-h-18
Z28 Grain tank 70% full indicator..................................................4-h-18
Measured value table: Item Component Measured Remark
value
K56 Remote control relay 95±10 Ω (Pin 85 - Pin 86)
15 A (Pin 30 - Pin 87a)
30 A (Pin 30 - Pin 87)
K76 Electronic relay ---
30a-2 Me-e-30a 09/06
TIC MEDION Electric system
Description of function:
Grain tank 70% full indicator When pressing microswitch Z28, warning light H17 lights up permanently
on the one hand, on the other hand the pulse buzzer (H44) is activated by
relays K76 and K77. K76 now remains locked in which can only be
stopped by actuating switch S63.
(see diagram 3).
The switch position II of function switch S40 (warning beacon) allows
linking the warning beacons to the grain tank 70% full indicator.
Grain tank 100% full When pressing microswitch Z27, warning light H16 lights up permanently
indicator on the one hand, on the other hand the pulse buzzer (H44) is activated by
relays K76 and K77. K76 now remains locked in which can only be
stopped by actuating switch S63 (see diagram 3).
Warning beacons circuit The switch position I of function switch S40 (warning beacon) allows
activating the warning beacons permanently.
The switch position II allows linking the warning beacons to the grain tank
70% full indicator.
09/06 Me-e-30a 30a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector HKAbl, KBAgn,
KBBgn, PHAbl, PVBge
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
HKAbl - 1 KBA19 K56/87 1.5 wh/vi
HKAbl - 14 PVB 8 K76/3 0.75 ye/gn
HKAbl - 15 PVB 13 K76/5 DI 15 0.75 wh/gr
KBAgn - 18 K56/30 1.5 bk/gn
KBAgn - 19 K56/87 HKA 1 1.5 wh/vi
KBAgn - 20 b3a 1.5 bk/vi
KBBgn - 6 EARTH PVA 21 PVB 6 MFB 1 MFB 2 4 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 BFA 2 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12
PHAbl - 2 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.5 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12 BFA 2
PHAbl - 14 K76/4 0.5 br/vi
PVBge - 7 a9a 0.5 bk
PVBge - 8 HKA 14 K76/3 0.75 ye/gn
PVBge - 13 HKA 15 K76/5 DI 15 0.75 wh/gr
30a-4 Me-e-30a 09/06
31a
Turn flasher system
Electric system MEDION TIC
31a Turn flasher system
Key to diagram: Coordinates
E24 Turn flasher, rear left..............................................................6-u-21
E25 Turn flasher, front left.............................................................5-g-19
E26 Turn flasher, rear right ...........................................................6-u-15
E27 Turn flasher, front right...........................................................5-g-17
H5 Trailer turn flasher signal light................................................3-g-18
H6 Vehicle turn flasher signal light ..............................................3-g-18
K57 Transducer.............................................................................4-g-17
S16 Turn flasher switch.................................................................3-g-18
S62 Hazard warning flasher switch...............................................3-g-18
X5 Connector ..............................................................................5-o-17
XB Connector ..............................................................................5-g-17
Measured value table: Item Component Measured Remark
value
K57 Transducer ---
31a-2 Me-e-31a 09/06
TIC MEDION Electric system
Description of function: None
09/06 Me-e-31a 31a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector Connector LSCgr Connector LSAgr
BLAgn, HKAbl, LSBgr
Connector RT1, WS II Socket RT1, WS II
Connector X5 Socket X5
Connector XB Socket XB
31a-4 Me-e-31a 09/06
TIC MEDION Electric system
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
BLAgn - 6 LSC 7 HKA 2 1.5 bk/wh
BLAgn - 12 LSC 8 HKA 3 1.5 bk/gn
HKAbl - 2 LSC 7 BLA 6 1.5 bk/wh
HKAbl - 3 LSC 8 BLA 12 1.5 bk/gn
LSAgr - 3 K57/C2 0.5 bl/rd
LSAgr - 7 b2a 1.5 bk
LSBgr - 4 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.5 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12 BFA 2
LSBgr - 10 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.5 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12 BFA 2
LSCgr - 7 BLA 6 HKA 2 1.5 bk/wh
LSCgr - 8 HKA 3 BLA 12 1.5 bk/gn
LSCgr - 10 K57/49a 2.5 wh/gn
LSCgr - 11 K57/49 2.5 bk/rd
LSCgr - 12 b5a 2.5 rd
09/06 Me-e-31a 31a-5
Electric system MEDION TIC
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
RT1 - 10 1.5 br
WS II - 1 0.5 bl/rd
WS II - 2 1.5 wh/gn
WS II - 5 1.5 bk
WS II - 10 0.5 or
X5-L 1.5 bk/wh
X5-R 1.5 bk/gn
X 5 - 31 1.5 br
XB - 2 1.5 bk/wh
XB - 3 1.5 br
XB - 4 1.5 bk/gn
31a-6 Me-e-31a 09/06
32a
Main light circuit, position light
Electric system MEDION TIC
32a Main light circuit, position light
Key to diagram: Coordinates
E35 Instrument lighting..................................................................2-g-18
E39 Position light, left....................................................................5-g-19
E40 Position light, rear left ............................................................6-u-21
E41 Position light, right..................................................................5-g-17
E42 Position light, rear right ..........................................................6-u-15
S17 Vehicle lighting main switch ...................................................2-g-18
X5 Connector ..............................................................................5-o-17
XB Connector ..............................................................................5-g-17
32a-2 Me-e-32a 09/06
TIC MEDION Electric system
Description of function: None
09/06 Me-e-32a 32a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector BLAgn, HKAbl, Connector KBBgn
LSBgr, PVAge, PVBge
Connector RT1 Socket RT1
Connector X5 Socket X5
Connector XB Socket XB
32a-4 Me-e-32a 09/06
TIC MEDION Electric system
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
BLAgn - 5 HKA 5 a7a 1.5 gr/bk
BLAgn - 13 HKA 4 a10a 1.5 gr/rd
HKAbl - 4 BLA 13 a10a 1.5 gr/rd
HKAbl - 5 BLA 5 a7a 1.5 gr/bk
KBBgn - 1 a5a 2.5 rd/bl
KBBgn - 2 b1e b4e 2.5 rd/ye
KBBgn - 4 a13e a10e a7e 2.5 gr
LSBgr - 10 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.5 br
BFA 2 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12
LSBgr - 11 PVA 18 a13a 0.5 gr/gn
PVAge - 18 LSB 11 a13a 0.5 gr/gn
PVBge - 6 EARTH PVA 21 PVB 6 MFB 1 MFB 2 0.75 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12 BFA 2
RT1 - 11 0.5 gr/gn
RT1 - 12 0.75 bl/bk
X 5 - 31 1.5 br
X 5 - 58L 1.5 gr/bk
X 5 - 58R 1.5 gr/rd
XB - 1 1.5 gr/bk
XB - 3 1.5 br
XB - 5 1.5 gr/rd
09/06 Me-e-32a 32a-5
Electric system MEDION TIC
32a-6 Me-e-32a 09/06
33a
Dipped headlights,
dipped headlights changeover
Electric system MEDION TIC
33a Dipped headlights, dipped headlights changeover
Key to diagram: Coordinates
E1 Dipped headlights, left ...........................................................5-f-19
E2 Dipped headlights, top left .....................................................2-e-19
E3 Dipped headlights, top right ...................................................2-e-17
E4 Dipped headlights, right .........................................................5-f-17
K49 Dipped headlights relay .........................................................4-g-17
K50 Dipped headlights relay .........................................................4-g-17
S15 Dipped headlights changeover switch ...................................2-g-18
S17 Vehicle lighting main switch ..................................................2-g-18
Measured value table: Item Component Measured Remark
value
K49 Remote control relay 95±10 Ω (Pin 85 - Pin 86)
K50 15 A (Pin 30 - Pin 87a)
30 A (Pin 30 - Pin 87)
33a-2 Me-e-33a 09/06
TIC MEDION Electric system
Description of function: None
09/06 Me-e-33a 33a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector BLAgn, KBAgn
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
BLAgn - 7 K50/87a 1.5 ye/br
BLAgn - 8 K50/87 1.5 ye/bk
BLAgn - 10 K49/87a 1.5 ye/rd
BLAgn - 11 K49/87a 1.5 ye/gr
KBAgn - 4 PHA 3 PVA 20 b6a BLA 14 HKA 10 1.5 bk
KBAgn - 13 K49/86 K50/86 0.75 wh/bl
33a-4 Me-e-33a 09/06
34a
Work lights
Electric system MEDION TIC
34a Work lights
Key to diagram: Coordinates
E8 Rear work lights ................................................................. 3-u-17/19
E9 Cab left outside work lights ................................................ 2-e-19
E10 Cab left inside work lights .................................................. 2-e-18
E12 Cab right outside work lights.............................................. 2-e-18
E13 Cab right inside work lights ................................................ 2-e-18
E17 Grain tank unloading tube work light ................................. 3-e-19
E50 Left parking light................................................................. 5-f-19/17
K52 Work lights far relay ........................................................... 4-g-17
K53 Right-hand cab work light relay ......................................... 4-g-17
K54 Left-hand cab work light relay............................................ 4-g-17
K60 Road travel release relay ................................................... 4-g-17
K64 Work light relay .................................................................. 4-g-17
K66 Tail light relay..................................................................... 4-g-17
S3 Work lights main switch .................................................... 2-g-18
Measured value table: Item Component Measured Remark
value
K52 Remote control relay 95±10 Ω (Pin 85 - Pin 86)
K53 15 A (Pin 30 - Pin 87a)
K54 30 A (Pin 30 - Pin 87)
K64
K66 Remote control relay 85± 7 Ω (Pin 85 - Pin 86)
20 A (Pin 30 - Pin 87a)
40 A (Pin 30 - Pin 87)
34a-2 Me-e-34a 09/06
TIC MEDION Electric system
Description of function: None
09/06 Me-e-34a 34a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector HKBbl, KBAgn Connector KBBgn
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
HKBbl - 10 K66/87 HKB11 1.5 gr/wh
HKBbl - 11 K66/87 HKB10 0.75 gr/ye
KBAgn - 2 a3a KBA8 1.5 gr/gn
KBAgn - 9 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.5 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
BFA 2 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12
KBAgn - 10 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.5 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12 BFA 2
KBAgn - 11 a16a KBA12 1.5 gr/ye
KBAgn - 12 K64/87 KBA12 1.5 gr/ye
KBAgn - 14 K52/86 K53/86 K54/86 0.75 gr/or
KBAgn - 15 K66/86 0.75 gr/vi
KBAgn - 21 b8a 0.75 bk/ye
34a-4 Me-e-34a 09/06
TIC MEDION Electric system
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
KBBgn - 6 EARTH PVA 21 PVB 6 MFB 1 MFB 2 4 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12 BFA 2
KBBgn - 7 a1a 1.5 gr/bl
KBBgn - 8 EARTH PVA 21 PVB 6 MFB 1 MFB 2 4 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12 BFA 2
09/06 Me-e-34a 34a-5
Electric system MEDION TIC
34a-6 Me-e-34a 09/06
35a
Grain tank,
sieve pan and returns lighting,
reversing horn, brake light
Electric system MEDION TIC
35a Grain tank, sieve pan and returns lighting, reversing horn, brake light
Key to diagram: Coordinates
E22 Left brake light .......................................................................6-u-21
E23 Right brake light .....................................................................6-u-15
E37 Grain tank lighting ..................................................................3-k-18
E48 Sieve pan lighting...................................................................4-s-16
E49 Returns lighting ......................................................................4-i-16
H41 Reversing horn.......................................................................5-g-18
K75 Additional power supply relay ................................................4-g-17
S48 Switch.....................................................................................3-g-18
U12 Sieve pan lighting switch (external) .......................................4-s-16
Z10 Brake light actual value switch...............................................5-g-18
Z62 Returns lighting actual value switch.......................................4-i-16
35a-2 Me-e-35a 09/06
TIC MEDION Electric system
Description of function: None
09/06 Me-e-35a 35a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector BLAgn, HKAbl, Connector X5 Socket X5
KBAgn, LSBgr
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
BLAgn - 3 FSA 4 b9a 1.5 bk
BLAgn - 4 LSB 14 1.5 br/ye
BLAgn - 14 PHA 3 PVA 20 b6a HKA 10 KBA4 1.5 bk
BLAgn - 15 HKA 6 1.5 bk/rd
HKAbl - 6 BLA 15 1.5 bk/rd
KBAgn - 1 CAC 18 a6a 1.5 rd
LSBgr - 4 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.5 br
LSB 10 BFA 2 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12
LSBgr - 14 BLA 4 1.5 br/ye
X5 - 54 1.5 bk/rd
35a-4 Me-e-35a 09/06
36a
Interior lights,
instrument lighting
Electric system MEDION TIC
36a Interior lights, instrument lighting
Key to diagram: Coordinates
E34 Interior lights ..........................................................................2-g-17
E35 Instrument lighting..................................................................4-g-17
S27 Interior lights switch ...............................................................2-g-17
X25 Plug-in connection for radio set,
wireless radio and mirror adjustment.....................................2-f-18
36a-2 Me-e-36a 09/06
TIC MEDION Electric system
Description of function: None
09/06 Me-e-36a 36a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector Connector KBBgn
KBAgn, PHAbl, PVAge
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
KBAgn - 1 CAC 18 a6a 1.5 rd
KBAgn - 4 PHA 3 PVA 20 b6a BLA 14 HKA 10 1.5 bk
KBAgn - 5 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.5 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 BFA 2
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12
KBBgn - 6 EARTH PVA 21 PVB 6 MFB 1 MFB 2 4 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12 BFA 2
36a-4 Me-e-36a 09/06
TIC MEDION Electric system
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
PHAbl - 2 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.5 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 BFA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12
PHAbl - 3 PVA 20 b6a BLA 14 HKA 10 KBA4 1.5 bk
PVAge - 20 b6a BLA 14 HKA 10 KBA4 PHA 3 1.5 bk
PVAge - 21 EARTH BFA 2 PVB 6 MFB 1 MFB 2 1.5 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12
09/06 Me-e-36a 36a-5
Electric system MEDION TIC
36a-6 Me-e-36a 09/06
37a
Windscreen wiper
Electric system MEDION TIC
37a Windscreen wiper
Key to diagram: Coordinates
E35 Instrument lighting..................................................................3-g-18
S43 Windscreen wiper switch .......................................................3-g-18
M15 Windscreen wiper motor ........................................................4-f-18
37a-2 Me-e-37a 09/06
TIC MEDION Electric system
Description of function: None
09/06 Me-e-37a 37a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector LSAgr
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
LSAgr - 1 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.5 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
BFA 2 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12
LSAgr - 2 a11a 1.5 bk/vi
M15 - 31 1.5 br
M15 - 31B 1.5 br/bl
M15 - 53 1.5 bk/bl
M15 - 53A 1.5 bk/vi
S43 - 10 1.5 br
S43 - 2 1.5 bk/vi
S43 - 3 1.5 vi
S43 - 5 1.5 br/bl
S43 - 6 1.5 bk/bl
S43 - 7 1.5 br
S43 - 9 1.5 bk/vi
37a-4 Me-e-37a 09/06
38a
Compressor-type air conditioner,
cab fan
- Automatic air conditioner see 38b
Electric system MEDION TIC
38a Compressor-type air conditioner, cab fan
Key to diagram: Coordinates
H12 Compressor-type air conditioner fault signal lamp ................4-g-17
K68 Cooling system relay..............................................................4-g-17
K75 Additional power supply relay ................................................4-g-17
M7 Cab fan motor ........................................................................2-f-18
R13 Cab fan series resistor ...........................................................2-f-18
S28 Cab fan switch .......................................................................2-f-18
Y32 Compressor-type air conditioner clutch solenoid coil ............3-j-19
Z22 Compressor-type air conditioner high pressure
actual value switch.................................................................2-j-17
Z23 Compressor-type air conditioner low pressure
actual value switch.................................................................2-j-17
Z24 Compressor-type air conditioner temperature
actual value switch.................................................................2-f-18
Measured value table: Item Component Measured Remark
value
K68 Remote control relay 85±7 Ω (Pin 85 - Pin 86)
K75 20 A (Pin 30 - Pin 87a)
40 A (Pin 30 - Pin 87)
Y32 Solenoid coils 3.0 A
4.0 Ω
38a-2 Me-e-38a 09/06
TIC MEDION Electric system
Description of function:
Compressor-type air The electro-magnetic clutch of the compressor-type air conditioner only
conditioner circuit switches as a function of the actuated relays K75 and K68. In addition, a
fan speed must be pre-selected.
Important! The system is pressure-monitored by switches Z22 and Z23.
- The high-pressure switch opens at 24 bar and closes at
18 bar.
- The low-pressure switch opens below 2 bar and closes at
2.25 bar.
If the earth signal fails due to one of the two gas-pressure
switches Z22 or Z23, the electro-magnetic clutch Y32 is
disengaged. This malfunction is displayed by warning
light H12.
09/06 Me-e-38a 38a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector HKAbl, KBAgn, Connector KBBgn
MOBbr, PVBge
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
HKAbl - 16 K68/85 0.75 gn/vi
KBAgn - 6 PVB 4 K68/86 0.75 rd/gn
KBBgn - 5 a8a 4 bk
KBBgn - 12 EARTH PVA 21 PVB 6 MFB 1 MFB 2 4 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 BFA 2
MOBbr - 9 K68/87 PVB 12 MOB 10 1.5 bk/gn
MOBbr - 10 MOB 9 K68/87 PVB 12 1.5 bk/gn
PVBge - 4 KBA6 K68/86 0.5 rd/gn
PVBge - 12 MOB 9 K68/87 MOB 10 0.75 gn/vi
38a-4 Me-e-38a 09/06
38b
Automatic air conditioner
-
Electric system MEDION TIC
38b Automatic air conditioner
Key to diagram: Coordinates
A6 Automatic air conditioner module ..........................................2-f-18
A7 Cab fan speed controller module...........................................2-f-18
B86 AC cab temperature sensor ...................................................2-g-17
B87 AC air discharge temperature sensor ....................................2-f-18
B88 AC outside temperature sensor .............................................2-g-19
H12 Compressor-type air conditioner fault signal light..................4-g-17
K68 Cooling system relay..............................................................4-g-17
K75 Additional power supply relay ................................................4-g-17
M7 Cab fan motor ........................................................................2-f-18
Y32 Compressor-type air conditioner clutch solenoid coil ............3-j-19
Y109 Heater solenoid coil ...............................................................2-f-18
Z22 Compressor-type air conditioner
high pressure actual value switch..........................................2-j-17
Z23 Compressor-type air conditioner
low pressure actual value switch ...........................................2-j-17
Z74 Anti-icing device (Climatic).....................................................2-f-18
Measured value table: Item Component Measured Remark
value
B86 Cab temperature sensor 20° - 97070 Ω blue;
-10° - 55330 Ω fault by flashing code
0° - 32650 Ω in display
B87 Air discharge 10° - 19900 Ω yellow;
temperature sensor 20° - 12490 Ω fault by flashing code
30° - 8057 Ω in display
B88 Outside temperature 40° - 5327 Ω red;
sensor fault by flashing code
50° - 3603 Ω
in display
60° - 2488 Ω
K68 Remote control relay 85±7 Ω (Pin 85 - Pin 86)
K75 20 A (Pin 30 - Pin 87a)
40 A (Pin 30 - Pin 87)
Y32 Solenoid coils 3.0 A
4.0 Ω
Y109 Solenoid coils 0.8 A Messrs. Konvekta
15 Ω
38b-2 Me-e-38b 09/06
TIC MEDION Electric system
Description of function: 1/7
Automatic air conditioner Together with the cab fan speed controller module (A7), the automatic air
conditioner module (A6) provides the complete temperature control inside
the cab.
This involves both actuating the compressor-type air conditioner clutch
solenoid coil (Y32) for the cooling compressor via relay K68 and switching
the heater circuit on and off if required via the heater solenoid coil (Y109)
until the set values are identical with the actual values of the
corresponding sensors.
The two closed gas-pressure switches Z22/Z23 must supply relay K68
with earth in order to allow the function of the compressor-type air
conditioner electro-magnetic clutch solenoid coil (Y32).
If the earth signal fails due to one of the two gas-pressure switches
(Z22/Z23), the compressor-type air conditioner electro-magnetic clutch
solenoid coil (Y32) disengages and this fault is displayed by the
compressor-type air conditioner fault signal light H12.
The anti-icing device switch Z74 prevents icing on the evaporator.
econ operation In this operating mode, the cooling compressor is not activated. The entire
air conditioner control is realised by the heater and the fan.
REHEAT function In this operating mode, the cooling compressor is permanently activated.
The ambient sensors (e.g. outside temperature sensor) is not considered
here.
Activation is for a defined period of time (see also Operator's Manual).
Test menu:
Key to diagram: 1 Key for activating the test menu
2 LED (without function in the test menu)
3 Key for activating the test menu
4 LED (without function in the test menu)
5 Key (without function in the test menu)
6 Key (without function in the test menu)
7 LED bar display indicates the evaporator fan speed
8 Display field (3 digits) Indicates the temperature in the test menu.
9 Display (1 digit). Indicates the measuring points in the test menu.
10 LED (without function in the test menu)
11 Key for leaving the test menu A RESET is triggered after
pressing this key.
12 LED (without function in the test menu)
13 Key for activating the test menu
LED (without function in the test menu)
09/06 Me-e-38b 38b-3
Electric system MEDION TIC
Description of function: 2/7
- Test menu operation
1. Switch on the ignition and start the engine.
2. Display of software version
The software version is displayed for 3 seconds.
If the software version flashes, the factory setting of the software in the
automatic air conditioner module (A6) was modified.
3. Temperature display
- Test menu access 1. Press key (3) and release it.
2. Press key (1) and hold it.
3. Press keys (11) and (13) simultaneously.
4. Release keys (1), (11) and (13) simultaneously.
The display field (8) shows the total of the factory software setting values
= 370.
If the setting value flashes, the factory software setting values in the
automatic air conditioner module (A6) were modified.
1st menu item Press key (3) once.
The cab temperature in °C is displayed.
Cab temperature
Example: 25.5°C
If the temperature display is incorrect, please check the following:
1. Position and possibly soiling of AC cab temperature sensor (B86),
(on the rear right, behind the suction lamellas).
2. Connector on the automatic air conditioner module (A6).
3. Measure the resistance of the AC cab temperature sensor (B86),
must be 10kOhm at 25°C.
4. Offset value of AC cab temperature sensor (B86) in the controller
menu.
38b-4 Me-e-38b 09/06
TIC MEDION Electric system
Description of function: 3/7
2nd menu item Press key (3) once.
The blow-out temperature in °C is displayed.
Blow-out temperature
Example: 29.3°C
If the temperature display is incorrect, please check the following:
1. Position and possibly soiling of the AC blow-out temperature
sensor (B87), (behind the large blow-out nozzle, top left).
2. Connector on the automatic air conditioner module (A6).
3. Measure the resistance of the AC blow-out temperature sensor
(B87), must be 10kOhm at 25°C.
4. Offset value of AC blow-out temperature sensor (B87) in the
controller menu.
rd
3 menu item Press key (3) once.
The outside temperature in °C is displayed.
Outside temperature
Example: 21.1°C
If the temperature display is incorrect, please check the following:
1. Position and possibly soiling of AC outside temperature sensor
(B88), (top left, below the roof cover, behind the fresh air filter).
2. Connector on the automatic air conditioner module (A6).
3. Measure the resistance of the AC outside temperature sensor
(B88), must be 10kOhm at 25°C.
4. Offset value of AC outside temperature sensor (B88) in the
controller menu.
th
4 menu item Press key (3) once.
The heater solenoid coil (Y109) is switched on.
Heater solenoid coil (Y109)
Example: Test step 4 is displayed
If the solenoid coil is not activated, please check the following:
1. Connector on the heater solenoid coil (Y109)
(top right, below the roof cover).
2. Voltage at the solenoid coil of 11.5 – 14.5 V, with the output
activated.
The solenoid coil must be connected.
3. Connector on the automatic air conditioner module (A6).
4. Check for short-circuit or break in the cable on the heater solenoid
coil (Y109).
09/06 Me-e-38b 38b-5
Electric system MEDION TIC
Description of function: 4/7
Important note: The further test steps (menu items) can be carried out only when a
voltage is applied to pin 1/1 of the automatic air conditioner module
(A6).
5th menu item Press key (3) once.
The compressor-type air conditioner electro-magnetic clutch solenoid
Compressor-type air coil (Y32) is activated.
conditioner electro-
magnetic clutch solenoid
coil Y32
Example: Test step 5 is displayed
If the electro-magnetic clutch (Y32) is not activated, please check the
following:
1. Connector on the compressor.
2. Fuse (F33, 1.5A) and compressor-type air conditioner relay
(K24)
3. Check electro-magnetic clutch mechanically
4. Connector on the automatic air conditioner module (A6).
5. Check for short-circuit or break in the cable on the
compressor-type air conditioner solenoid coil electro-
magnetic clutch (Y32).
The solenoid is deactivated again when selecting the next menu item.
th
6 menu item Press key (3) once.
The fan speed (30%) of the cab fan (M7) is activated.
Fan speed (30%)
Cab fan (M7)
Example: Test step 6 is displayed
The speed is displayed as a bar display.
If the cab fan does not start, please check the folllwing:
1. Connector on the evaporator fan below the roof cover.
Slacken off the cover screws and remove the cover.
2. Check the cab fan motor mechanically. Abraded particles of
carbon brushes
3. Connector on the automatic air conditioner module (A6).
4. Fuse (F33, 1.5A)
5. Check cable to the cab fan motor (M7) for short-circuit or
break.
38b-6 Me-e-38b 09/06
TIC MEDION Electric system
Description of function: 5/7
7th menu item Press key (3) once.
The fan speed (50%) of the cab fan (M7) is activated.
Fan speed (50%)
Cab fan (M7)
Example: Test step 7 is displayed
The speed is displayed as a bar display.
If the cab fan does not start, please check the folllwing:
1. Connector on the cab fan (below the roof cover).
2. Check the cab fan motor mechanically. Abraded particles of
carbon brushes
3. Connector on the automatic air conditioner module (A6).
4. Fuse (F33, 1.5A)
5. Check cable to the cab fan motor (M7) for short-circuit or break.
th
8 menu item Press key (3) once.
The fan speed (80%) of the cab fan (M7) is activated.
Fan speed (80%)
Cab fan (M7)
Example: Test step 8 is displayed
The speed is displayed as a bar display.
If the cab fan does not start, please check the folllwing:
1. Connector on the cab fan (below the roof cover).
2. Check the cab fan motor mechanically. Abraded particles of
carbon brushes
3. Connector on the automatic air conditioner module (A6).
4. Fuse (F33, 1.5A)
5. Check cable to the cab fan motor (M7) for short-circuit or break.
09/06 Me-e-38b 38b-7
Electric system MEDION TIC
Description of function: 6/7
9th menu item Press key (3) once.
The fan speed (100%) of the cab fan (M7) is activated.
Fan speed (100%)
Cab fan (M7)
Example: Test step 9 is displayed
The speed is displayed as a bar display.
If the cab fan does not start, please check the folllwing:
1. Connector on the cab fan (below the roof cover).
2. Cab fan speed controller module (A7) below the roof cover.
Slacken off the cover screws and remove the cover.
3. Voltage on the cab fan motor. Target value: 11.5 - 14.5 V. The cab
fan speed controller module (A7) must be connected.
4. Check the cab fan motor mechanically. Abraded particles of
carbon brushes
5. Connector on the cab fan speed controller (A7)
6. Fuse (F33, 1.5A)
7. Check cable to the cab fan motor (M7) for short-circuit or break.
th
10 menu item Press key (3) once.
All outputs of the automatic air conditioner module (A6) are activated.
Automatic air conditioner
module (A6) outputs
Example: Test step 10 is displayed
The speed is displayed as a bar display.
1. The heater solenoid coil (Y109) is switched on.
2. The compressor-type air conditioner electro-magnetic clutch
solenoid coil (Y32) is activated.
3. The cab fan motor (M7) is switched on and works at max. speed.
38b-8 Me-e-38b 09/06
TIC MEDION Electric system
Description of function: 7/7
11th menu item Press key (3) once.
All segments of the bar and seven-segment displays are switched on.
Segment display
All segments of the seven-segment displays are switched on.
All segments of the bar displays are switched on.
The display function can be checked by visual control.
12th menu item Press key (3) once. The automatic air conditioner module (A6)
performs a RESET. Now the software version is displayed – the
automatic air conditioner module (A6) now is in normal operation
again.
Leaving the menu
The software version is displayed.
09/06 Me-e-38b 38b-9
Electric system MEDION TIC
Connector pin
assignment:
Connector HKAbl, KBAgn, Connector KBBgn
MOBbr, PVBge
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
A6 - 1/1 0.75 bl
A6 - 1/2 0.75 bk
A6 - 1/ 0.75 bk
A6 - 1/6 1.0 br
A6 - 2/2 1.5 bk/ye
A6 - 2/3 1.5 bk/vi
A6 - 2/9 0.75 bk
A7 - 1 2.5 br
A7 - 4 2.5 rd/bl
A7 - 5 2.5 bl/wh
A7 - 7 1.5 bk/vi
A7 - 8 2.5 bk
HKAbl - 16 K68/85 0.75 gn/vi
KBAgn - 6 PVB 4 K68/86 0.75 rd/gn
KBAgn - 7 LSB 5 K61/86 MOB 15 KBA 7 0,75 bl
KBBgn - 5 a8a 4 bk
KBBgn - 6 EARTH PVA 21 PVB 6 MFB 1 MFB 2 4 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 BFA 2 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12
MOBbr - 9 K68/87 PVB 12 MOB 10 1.5 bk/gn
MOBbr - 10 MOB 9 K68/87 PVB 12 1.5 bk/gn
PVBge - 4 KBA6 K68/86 0.5 rd/gn
PVBge - 12 MOB 9 K68/87 MOB 10 0.75 gn/vi
38b-10 Me-e-38b 09/06
39a
Air-suspended seat compressor
Electric system MEDION TIC
39a Air-suspended seat compressor
Key to diagram: Coordinates
M8 Operator's seat compressor...................................................4-h-18
39a-2 Me-e-39a 09/06
TIC MEDION Electric system
Description of function: None
09/06 Me-e-39a 39a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector FSAgr
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
FSAgr - 4 BLA 3 b9a 1.5 bk
FSAgr - 5 EARTH PVA 21 PVB 6 MFB 1 MFB 2 1.5 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 K64/85 VSA 4 DO 22 BFA 2
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12
39a-4 Me-e-39a 09/06
40a
Additional sockets
Electric system MEDION TIC
40a Additional sockets
Key to diagram: Coordinates
X20 Plug-in connection for additional devices ..............................4-g-17
X28 Plug-in connection for additional devices ..............................4-g-17
40a-2 Me-e-40a 09/06
TIC MEDION Electric system
Description of function: None
09/06 Me-e-40a 40a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector ASAgn, ZGAvio Connector PVAge
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
PVAge - 1 PHA 15 K72/86 b10a MOA 1 K71/86 1.5 bk/gr
PVAge - 21 EARTH BFA 2 PVB 6 MFB 1 MFB 2 1.5 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 ZGA 4
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12
ZGAvio - 1 b16a ZGA 2 1.5 rd
ZGAvio - 2 b16a ZGA 1 1.5 rd
ZGAvio - 3 EARTH BFA 2 PVB 6 MFB 1 MFB 2 1.5 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 PVA 21
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12
ZGAvio - 4 EARTH BFA 2 PVB 6 MFB 1 MFB 2 1.5 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA17 K64/85 VSA 4 DO 22 FSA 1
APA 8 MOA 2 HKA 19 PHA 2 KNA 2
K79/30 K57/31 K61/85 K52/85 K53/85
K66/85 K69/87a K70/87a K71/87a K72/87a
K75/85 K77/85 BFA 3 ASA 1 KBA 5
KBA 9 KBA 10 K54/85 ZGA 3 PVA 21
LSA 1 HDA 8 MOB 2 FSA 5 K49/85
K50/85 KBB 12
40a-4 Me-e-40a 09/06
50a
Electric mirror adjustment
Electric system MEDION TIC
50a Electric mirror adjustment
Key to diagram: Coordinates
M19 Left mirror adjustment motor ..................................................2-f-21
M20 Right mirror adjustment motor................................................2-f-15
S50 Mirror adjustment switch ........................................................2-g-19
X25 Mirror adjustment connector ..................................................2-f-18
50
50a-2 Me-e-50a 09/06
TIC MEDION Electric system
Description of function: None
09/06 Me-e-50a 50a-3
Electric system MEDION TIC
Connector pin
assignment:
Connector Socket X25
KBAgn
Interconnection list:
from to 1 to 2 to 3 to 4 to 5 mm² Colour
KBAgn - 1 CAC 18 a6a 1.5 rd
KBAgn - 4 PHA 3 PVA 20 b6a BLA 14 HKA 10 1.5 bk
KBAgn - 5 EARTH PVA 21 PVB 6 MFA 1 MFA 2 1.5 br
LSB 10 LSB 4 PVC 12 CAC 8 CAC 17
AP 8 AP 9 KBB 6 KBB 8 K60/85
KBA 17 MOA 2 HKA 19 PHA 2 FSA 1
APA 8 K57/31 K61/85 K52/85 KNA 2
K79/30 K69/87a K70/87a K71/87a K53/85
K66/85 K77/85 BFA 3 ASA 1 K72/87a
K75/85 KBA 10 K54/85 ZGA 3 KBA 5
KBA 9 LSA 1 HDA 8 MOB 2 ZGA 4
FSA 5 K49/85 K50/85 K73/31 KBB 12
BFA 2
50
50a-4 Me-e-50a 09/06
TIC MEDION Electric system
09/06 Me-e-50a 50a-5
Component grid
TIC MEDION Electric system
Component grid
09/06 Me-e-raster R-2
Electric system MEDION TIC
R-3 Me-e-raster 09/06
Index
Electric system MEDION TIC
Index Circuit Diagram
A AC air discharge temperature 38
AC anti-icing device (Climatic) 38
AC cab temperature 38
AC outside temperature 38
ACT 27
Air filter maintenance 3
All-wheel drive 29
AUTOCONTOUR (CAC) 20, 24
Automatic air conditioner 38
Automatic ground pressure control 24
AUTOPILOT (ATP) 28
B Baffle plate position 25
Battery 1
Brake light 35
Brake lining wear 26
Buzzer 3
C Cab fan 38
Cab fan speed controller 38
CAC / Contour main switch 24
Centralizing switch (set value) 28
Circulation shut-off valve 28
Climatic 38
Compressor-type air conditioner 38
CONTOUR 24
Coolant level 3
Coolant temperature 2, 3
Cutterbar fold reversing valve 23
Cutterbar spring pre-stress 24
Cutterbar transverse control (manual) 20
Cutting height control 24
D Daimler-Chrysler diagnosis plug 2
Deflector adjustment 12
Delete warning tone 30
Diesel engine 2, 3, 5, 25, 27
Diesel engine STOP 3
Diode PCB 2, 3, 24, 25, 26, 30
Dipped headlights 33
Dipped headlights changeover 33
Disconnector 1
E Electric starting motor 1
Electronic engine control 2
Engine adaptation (ADM) 1, 2
Engine fuse block ZE, 2
Engine speed adjustment 2
Engine temperature 2, 3
index-2 Me-e-index 06/07
TIC MEDION Electric system
Circuit Diagram
F Fan 5, 10, 27
Feeder housing 24, 25
Fieldwork computer 5
Folding the cutterbar 21, 23
Front attachment 17
Front attachment clutch 17
Front attachment working position 5, 27
Fuel level 26
Fuel pump 2
Fuses ZE
G Generator 1
Generator charging light 1
Grain elevator 25
Grain tank 100% full 30
Grain tank 100% full indicator 30
Grain tank 70% full 30
Grain tank lighting 35
Grain tank unloading 15
Ground speed 5
Ground speed control lever safety start switch 1
H Hazard warning flasher 31
Heater 38
Hour meter indicator 10
I Ignition switch 1
Interior lights 36
M Main drive (threshing mechanism clutch) 1, 7, 17, 24
Mirror adjustment 50
Multi-function handle module 14, 15, 17, 20, 21, 24
O Oil pressure 3
Operator's seat compressor 39
P Parking brake 26
Parking light 34
Performance monitor 12
Pre-set cutting height control 24
R Rake up 19
Reel adjustment 21
Reel end position 23
Reel speed adjustment 19
Resistor (CAN matching resistor) 27
Returns 25
Returns lighting 35
Reverse front attachment 17
Reversing horn 26
Reversing horn 35
Road travel (red) 4, 20, 30
06/07 Me-e-index index-3
Electric system MEDION TIC
Circuit Diagram
S Safety shutdown switch 7
Seat contact 14, 15, 17, 28
Sensing band 24
Side light 32
Sieve pan lighting 35
Slip / standstill 25
Solenoid 2
Speed indicator 10
Speed monitor (DZW) 25
Start of flow adjustment 2
Steering position 26
STOP 3
Straw chopper 25
Straw jam 26
Straw walker 25
Swinging the grain tank unloading tube 14
T Temperature 3
Threshing drum 5, 10, 27
Threshing mechanism clutch 7
Transmission (ground speed) 5
Turn flasher light 31
U Unloading tube position 15
V Vehicle lighting main switch 32, 33
W Warning beacon 30
Warning light 3
Windscreen wiper 37
Work lights 34
Work lights main switch 34
Y YIELD METER (LEM) 27
index-4 Me-e-index 06/07
At CLAAS KGaA mbH we are constantly improving
our products to reflect the latest technological develop-
ments. For this reason, we may from time to time need
to make changes to diagrams and descriptions in this
documentation which do not reflect products which
have already been delivered and which will not be
implemented on these machines.
Technical data, dimensions and weights are given
as an indication only. Responsibility for errors or
omissions not accepted.
Reproduction or translation of this publication, in
whole or part, is not permitted without the written
consent of the CLAAS KGaA mbH.
All rights under the provision of the Copyright Act
are reserved.
CLAAS KGaA mbH
33426 Harsewinkel
Germany
Our contribution to the environment:
CLAAS have printed this manual
on 100 % chlorine free paper.
CLAAS KGaA mbH
Postfach 1163
33426 Harsewinkel
Tel. +49 (0)5247 12-0
www.claas.com
0293 824.2
SYS-E MEDION 340 – 310
From serial number: 934 00610
932 02724
EN - 07.07 - NF
Printed in Germany