Bungalow House Plan
Bungalow House Plan
E E A
PERSPECTIVE
SITE DEVELOPMENT PLAN BUILDING OFFICIAL
R R 1 VICINITY MAP
TABLE OF CONTENTS
C C FOUNDATION PLAN
DETAIL OF C1F1
T T S DETAIL OF WF
ROOF FRAMING PLAN
LINE & GRADE
I I 1 DETAIL OF ROOF BEAM
GENERAL CONSTRUCTION NOTES
V V
E E
S ROOF PLAN ARCHITECTURAL
ROOF FRAMING PLAN
2 SPOT DETAILS
W N W N 1 ELECTRICAL NOTES
RISER DIAGRAM
ELECTRICAL
SE
U
HO
AL
E
US
I
NT
HO
DE
AL
SI
S E S E
RE
I
NT
AY
DE
W
SI
F-
RE
-O
HT
G
THIS SITE
GROUND FLOOR SEWER LAY - OUT
RI
PLUMBING NOTES
N
DE
SI
LEGENDS/SYMBOLS
ISSUED ON :
TIN. :
PRC No. :
P.T.R. No. :
ISSUED ON :
TIN. :
PRC No. :
FOUND THEREIN.
2. COPYRIGHT OF THIS DRAWING
COPYING OR REPRODUCING SUCH DRAWING
WITHOUT THE DESIGNERS CONSENT
REVISIONS:
OWNER
AS SHOWN
A-1
IS ILLEGAL. DATE: LOCATION : CABAROAN DAYA, VIGAN CITY, ILOCOS SUR
ISSUED AT : DATE: ISSUED AT : DATE:
A B C
6.00
3.00 3.00
1.20 1.05
W1 W1
1
D2
ROOF LINE ELEV. 0+3.50 ROOF LINE ELEV. 0+3.50
BEDROOM 2
TOP OF UPPER ROOF BEAM ELEV. 0+3.20 TOP OF UPPER ROOF BEAM ELEV. 0+3.20
2.55 W1 W1 ELEV. 0+2.90 ELEV. 0+2.90
DINING CEILING & CANOPY LINE CEILING & CANOPY LINE
AREA/KITCHEN
D2
2
6.00
1.19
LIVING D3 CR W3
ROOM
CONCRETE CANOPY
2.45
W2 W1
4
0.90 0.70
0.60
2.10
2.10
2.10
ROOF LINE ELEV. 0+3.50 ROOF LINE ELEV. 0+3.50
MARK: D1 MARK: D2
TOP OF UPPER ROOF BEAM ELEV. 0+3.20 TOP OF UPPER ROOF BEAM ELEV. 0+3.20 TYPE: WOODEN PANEL DOOR TYPE: WOODEN PANEL DOOR
MARK: D3
TYPE: WOODEN PANEL DOOR
CEILING & CANOPY LINE ELEV. 0+2.90 CEILING & CANOPY LINE ELEV. 0+2.90 LOCATION: MAIN ENTRANCE LOCATION: CR
LOCATION: CR
NO. OF UNITS: 1 NO. OF UNITS: 3
NO. OF UNITS: 1
0.40
NGL ELEV. 0+00 NGL ELEV. 0+00
1.20
1.50
2.10
2.10
2.10
FFL
MARK: W1 MARK: W3 MARK: W2
TYPE: ALUMINUM WINDOW TYPE: ALUMINUM WINDOW TYPE: ALUMINUM WINDOW
LOCATION: BEDROOMS
LOCATION: COMFORT ROOM LOCATION: BEDROOMS 2ND FLOOR
NO. OF UNITS: 6
NO. OF UNITS: 2 NO. OF UNITS: 2
ISSUED ON :
TIN. :
PRC No. :
P.T.R. No. :
ISSUED ON :
TIN. :
PRC No. :
FOUND THEREIN.
2. COPYRIGHT OF THIS DRAWING
COPYING OR REPRODUCING SUCH DRAWING
WITHOUT THE DESIGNERS CONSENT
REVISIONS:
OWNER
AS SHOWN
A-2
IS ILLEGAL. DATE: LOCATION : CABAROAN DAYA, VIGAN CITY, ILOCOS SUR
ISSUED AT : DATE: ISSUED AT : DATE:
A B C 0.80
6.00
0.25
3.00 3.00
0.25
0.80
4 - 16 mm Ø COLUMN BARS
1 C1F1
WF1 WF1 10 mm Ø HOR. BARS @ 10 mm Ø HOR. BARS @
12 - 16 mm Ø MATTING BARS 0.60 M. O.C. 0.60 M. O.C.
2.55
WF1 WF1 PLAN
WF2 5" CHB W/ PLAIN 4" CHB W/ PLAIN
CEMENT PLASTER FIN. CEMENT PLASTER FIN.
WF2
12 mm Ø VER. BARS @ 12 mm Ø VER. BARS @
2 C1F1 C1F1
NAT. GRADE LINE 0.60 M. O.C. 0.60 M. O.C.
WF2
6.00
1.19
N. G. L. 3 - 10 mm Ø LONGIT. N. G. L. 3 - 10 mm Ø LONGIT.
BARS BARS
2.45
WF1
0.65
0.40
0.40
10 mm Ø CUT BARS @ 10 mm Ø CUT BARS @
WF2 0.30 M. O.C. 0.30 M. O.C.
WF1 WF1
0.20
0.20
WF2
3 10 mm Ø LATERAL TIES SPACED AT 1 @ 0.40 0.40
0.25
1.00
L/4 L/4 0.20 The structural drawings and specifications represent the general framework of the structure. They
2- 16 MM Ø TOP BARS
do not indicate methods of construction, unless so stated, the contractor/implementer shall provide all
1 2 - 16 MM Ø TOP BARS necessary measures to protect the structure, workmen and other persons during all phases of
0.30
construction. It is the contractor/implementer obligation to notify the Structural Engineer of any
2 - 16 MM Ø BOT BARS
conditions that may endanger the stability or cause distress in the structure during phases of construction.
2.55
The contractor/implementor shall provide temporary erection bracings and shoring for all the
6.00
The contractor/implementor shall take all necessary steps to ensure proper alignment of each
member of the structure, avoiding unnecessary eccentricities after the installation of all structural and
finish materials.
3
1.00
4 ROOF BEAM FRAMING PLAN 5 DETAIL OF ROOF BEAM 6 GENERAL CONSTRUCTION NOTES
S-1 SCALE: 1:100 M. S-1 SCALE: NTS. S-1 SCALE: 1:20 M.
ISSUED ON :
TIN. :
PRC No. :
P.T.R. No. :
ISSUED ON :
TIN. :
PRC No. :
FOUND THEREIN.
2. COPYRIGHT OF THIS DRAWING
COPYING OR REPRODUCING SUCH DRAWING
WITHOUT THE DESIGNERS CONSENT
REVISIONS:
OWNER
AS SHOWN
S-1
IS ILLEGAL. DATE: LOCATION : CABAROAN DAYA, VIGAN CITY, ILOCOS SUR
ISSUED AT : DATE: ISSUED AT : DATE:
OWNER
S-1
IS ILLEGAL. DATE: LOCATION : CABAROAN DAYA, VIGAN CITY, ILOCOS SUR
ISSUED AT : DATE: ISSUED AT : DATE:
REF.
C.O. LOCAL TELEPHONE
TEL TEL
PB C.O.
SERVICE ENTRANCE
CATV CATV
3
LOCAL CABLE TV
SERVICE ENTRANCE
SERVICE ENTRANCE
220 V, 60 Hz, 2-WIRE
SINGLE PHASE
CLASS 100
USE: 2 - 22 mm² THW
TEL
C.O. IN 1 41" Ø RSC PIPE
KILOWATT-HR
METER, 220 V,
60 Hz, SINGLE
PHASE
CATV
C.O. 2
TEL
CATV
C.O.
TEL
CATV
C.O. TEL
CATV LOAD COMPUTATION
TO TELEPHONE OUTLET
TO CABLE TV OUTLET
C.O.
ISSUED ON :
TIN. :
PRC No. :
P.T.R. No. :
ISSUED ON :
TIN. :
PRC No. :
FOUND THEREIN.
2. COPYRIGHT OF THIS DRAWING
COPYING OR REPRODUCING SUCH DRAWING
WITHOUT THE DESIGNERS CONSENT
REVISIONS:
OWNER
AS SHOWN
E-1
IS ILLEGAL. DATE: LOCATION : CABAROAN DAYA, VIGAN CITY, ILOCOS SUR
ISSUED AT : DATE: ISSUED AT : DATE:
OWNER
E-1
IS ILLEGAL. DATE: LOCATION : CABAROAN DAYA, VIGAN CITY, ILOCOS SUR
ISSUED AT : DATE: ISSUED AT : DATE:
WATER
WATER
PUMP
TANK
GV
TO CATCH 1/2" Ø
BASIN
1/2" Ø KS
50MM Ø
KS
20 mm Ø SHO w/ FAU
VSTR
CO
LAV WC
LAV WC
20 mm Ø WC
FD 20 mm Ø LAV
110 mm Ø FCO
50 mm Ø FD
110 mm Ø WC
50 mm Ø LAV
SEPTIC VAULT
0.60 10 PERSONS 1.20 0.90 1.80 1. SEPTIC TANK ARE NO LONGER ALLOWED IN THE CITY OR TOWN
15 PERSONS 1.20 1.10 2.20
WHERE NEW SANITARY SEWER IS IN USE, HOWEVER THEY MAY STILL
20 PERSONS 1.20 1.25 2.50
OF GREAT SERVICE IN SUB - URBAN COMMUNITIES SYSTEM OF
0.60
35 PERSONS 1.30 1.60 3.20 DISPOSAL IS IN FUNCTION BUT WHERE SEWER IS NOT AVAILABLE.
540
70 PERSONS
1.50
160
1.95
2.00
3.90
4.00
80 PERSONS 160 2.20 4.40 3. SEPTIC TANK SHOULD BE BUILT WATER TIGHT OF CONCRETE,
PLAN OF SEPTIC VAULT
90 PERSONS 1.80 2.20 4.40
STONE, BRICKS.
100 PERSONS 1.80 2.30 4.60
3 PLAN
P-1 SCALE: 1:30 M.
6 PLAN OF SEPTIC VAULT 4. ALL COMPARTMENT OR CHAMBERS MUST BE PROVIDED EACH WITH
MANHOLE AND WELL FITTED TIGHT COVERS USED AS ENTRY IN
P-1 SCALE: 1:100 M. CLEANING AND REPAIRING.
LENGTH "L" 0.90M MIN. 5. INLET AND OUTLET SHALL BE WELL ARRANGED IN SUCH A WAY THAT
0.60 NEITHER SLUDGE NOR SCUM BE UNDULY DISTURBED.
0.15
FLOOR DRAIN
SECTION OF MANHOLE CO CLEAN-OUT RED REDUCER
8. A MINIMUM OF 300 mm SHOULD BE LEFT AS AIR SPACE BETWEEN
AV AIR VENT HB HOSE BIB
THE TOP OF THE SEWAGE AND UNDER THE TANK COVER.
0.20
SECTION
ISSUED ON :
TIN. :
PRC No. :
P.T.R. No. :
ISSUED ON :
TIN. :
PRC No. :
FOUND THEREIN.
2. COPYRIGHT OF THIS DRAWING
COPYING OR REPRODUCING SUCH DRAWING
WITHOUT THE DESIGNERS CONSENT
REVISIONS:
OWNER
AS SHOWN
P-1
IS ILLEGAL. DATE: LOCATION : CABAROAN DAYA, VIGAN CITY, ILOCOS SUR
ISSUED AT : DATE: ISSUED AT : DATE:
ROOF LINE
.80M OFFSET
FLASHING GUTTER
FLASHING GUTTER
3" TEKSCREW
GUTTER
0.50MM THK PREPAINTED
METAL ROOFING SHEET
FLASHING GUTTER
2" X 3" X 1.2MM THK C-PURLINS
SPACED @ 0.60 m. O.C.
ISSUED ON :
TIN. :
PRC No. :
P.T.R. No. :
ISSUED ON :
TIN. :
PRC No. :
FOUND THEREIN.
2. COPYRIGHT OF THIS DRAWING
COPYING OR REPRODUCING SUCH DRAWING
WITHOUT THE DESIGNERS CONSENT
REVISIONS:
OWNER
AS SHOWN
S-2
IS ILLEGAL. DATE: LOCATION : CABAROAN DAYA, VIGAN CITY, ILOCOS SUR
ISSUED AT : DATE: ISSUED AT : DATE: