0% found this document useful (0 votes)
4 views8 pages

drts6[1]

The DRTS-6 is an advanced protection relay test set designed for testing various types of protection relays, energy meters, and transducers with high accuracy. It features multiple current and voltage outputs, and can handle a wide range of testing applications, including both AC and DC measurements. The device is lightweight and portable, with options for enhanced precision and additional amplifiers for high current testing.

Uploaded by

HUY NGUYỄN
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
4 views8 pages

drts6[1]

The DRTS-6 is an advanced protection relay test set designed for testing various types of protection relays, energy meters, and transducers with high accuracy. It features multiple current and voltage outputs, and can handle a wide range of testing applications, including both AC and DC measurements. The device is lightweight and portable, with options for enhanced precision and additional amplifiers for high current testing.

Uploaded by

HUY NGUYỄN
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

D RT S - 6

A DVA N C E D P ROT E C T I O N R E L AY T E S T S E T
AND MEASUREMENT SYSTEM

MULTI-TASKING EQUIPMENT DESIGNED FOR TESTING


PROTECTION RELAYS, ENERGY METERS, TRANSDUCERS
POWERFUL AND LIGHTWEIGHT
HIGH ACCURACY: BETTER THAN 0.1% (STANDARD); HP MODEL BETTER THAN 0,05%
UP TO 9 CURRENT AND 4 VOLTAGE OUTPUTS PLUS AUXILIARY D.C. SUPPLY

APPLICATION
DRTS-6 CAN TEST ALL
THE FOLLOWING RELAYS

RELAY TYPE IEEE No

Distance relay 21
Synchronizing device 25
Under/over-voltage relay 27/59
Directional Power relay 32
Field relay 40
Reverse phase current relay 46
Phase sequence voltage relay 47
Incomplete sequence relay 48
Instantaneous over-current relay 50
Inverse time over-current relay 51
Power factor relay 55
Voltage balance relay 60
Ground detector relay 64
Directional over-current relay 67 DRTS-6 has been designed to test:
Phase angle out of step relay 78
Automatic reclosing relay 79 ALL PROTECTION RELAYS;
Frequency relay 81
WATT-HOUR METERS;
Pilot wire receiver relay 85
Lockout relay 86 TRANSDUCERS;
Differential protection relay 87 METERS.
Voltage directional relay 91
Power directional relay 92
Tripping relay 94

.1.
DRTS-6 SPECIFICATION . Fourth voltage output V4 (AC/DC);
. Zero-sequence component
S IX PHASE AC / DC CURRENT OUTPUTS VO = (V1+V2+V3)/3 or
VO = (V1 + V2 + V3/1.73).
AC/DC CURRENT OUTPUTS BATTERY SIMULATOR
Output voltage: 0…260 V D.C.,
RANGE CONNECTION CURRENT POWER ZMAX RESOLUTION program controlled.
A VA Ohm Power: 100 W or 2 A on all range;
1 6 X DIRECT 0...15 80 0.35 230 µA continuous duty.
2 6 X DIRECT 0...1.5 0.35 23 µA Accuracy: ± 1%.
3 6 X DIRECT 0...0.15 0.35 2 µA Automatic protection for overloads.
4 3 X DIRECT 0...15 100 0.44 230 µA Step or ramp control
5 3 X DIRECT 0...1.5 0.44 23 µA
6 3 X DIRECT 0... 0.15 0.44 2 µA ANGLES
7 3 X 2 IN PARALLEL 0... 30 160 0.18 460 µA Phase angle range: 0°- 360°.
8 3 X 2 IN PARALLEL 0... 3 0.18 46 µA Angle resolution: 0.01°.
9 3 X 2 IN PARALLEL 0... 0.3 0.18 5 µA
10 3 X 2 IN SERIES 0... 15 160 0.71 230 µA Angle accuracy: ± 0.1°.
11 2 X 3 IN PARALLEL 0... 45 240 0.12 690 µA Step or ramp control.
12 1 X 6 IN PARALLEL 0... 90 480 0.06 1.38 mA OUTPUT FREQUENCY
13 1 X SERIES OF 2 IN PARALLEL 0... 30 320 0.35 460 µA
Frequency range: from d.c. (0 Hz)
to 2000 Hz.Transient 5 kHz.
Six independent current sources with a common neutral. Capable of generating different
Independent adjustment of current outputs. frequencies on any output.
Duty cycle: continuous. Maximum frequency error:
25 µHz (0.5 ppm).
Waveform resolution: 28 bit. Resolution: 0.1 mHz.
Capable of stepping or ramping the current. Capable of generating waveform with
Rate of change programmable between ± 0.001 A/s and ± 999 A/s. superimposed harmonic distortion.
Output accuracy: ± 0.025% typical, ± 0.1% guaranteed. LOW LEVEL SIGNAL OUTPUTS
Distortion: 0.03% total maximum. The purpose of these low voltage
Automatic protection for overloads. outputs is to test protection relays that
use transducers such as Rogowsky coils
FOUR PHASE AC/DC VOLTAGE OUTPUTS and voltage dividers; for this simulation
low voltage inputs are necessary.
AC/DC VOLTAGE OUTPUTS Number of outputs: 6.
Full range V & I output: 0... 7.26 V rms.
RANGE CONNECTION VOLTAGE POWER ZMAX RESOLUTION Frequency: DC to 20 kHz.
V VA Ohm Output current: 5 mA max.
1 4 X DIRECT 0…125 85 195 1.9 mV Resolution: 0.43 mV or 0.043 mV.
2 3 X DIRECT 0…12.5 195 190 µV Accuracy: 0.02% typical, 0.1% guaranteed.
3 3 X DIRECT 0…1 195 19 µV Distortion: 0.01% typical.
4 1 X 2 IN SERIES 0…250 160 390 3.8 mV
5 1 X 2 IN PARALLEL 0…125 160 97 1.9 mV BINARY INPUTS
OPTIONAL 300 V OUTPUT 10 binary inputs clean or with voltage
1 4 X DIRECT 0... 300 85 1125 4.6 mV from 24 to 250 Vac and 4 to 300 Vdc,
2 3 X DIRECT 0... 125 85 195 1.9 mV separated in two groups of 5, with two
3 3 X DIRECT 0... 12.5 195 190 µV common points isolated at 1 kVac.
4 1 X 2 IN SERIES 0... 600 160 390 9.2 mV Selection of the type of input:
5 1 X 2 IN PARALLEL 0... 300 160 97 4.6 mV Voltage clean; 5 - 24 - 48 - 110 V;
software controlled.
Selection of input debounce:
Four independent voltage sources, with a common neutral. from 0 to 2,000 µs; software controlled.
Independent adjustment of voltage outputs. Timer range: 0 - 999,999.9999 s
Duty cycle: continuous. (277 hours) or, in cycles:
0 - 50,000,000 cycles (50 Hz);
Waveform resolution: 28 bit. 0 - 60,000,000 cycles (60 Hz).
Capable of stepping or ramping the voltage. Resolution: 0.1 ms, 0.005 cycles.
Rate of change programmable between ± 0.001 V/s and ± 999 V/s. Timer accuracy: 0.01% of reading ± 0.1 ms.
Event recording resolution: 1 ms.
Voltage accuracy: ± 0.1% of the value, ± 0.02% of the range.
Distortion: 0.1% total maximum. COUNTER INPUTS
Automatic protection for overloads and counter-feed. These inputs allow testing energy meters,
including high frequency outputs.
The fourth voltage output can be selected to act as:
Number of inputs: 2; with no common zero point. POWER SUPPLY
Frequency range: 0 to 50 kHz. Mains power supply: 90 to 264 VAC
AUXILIARY OUTPUTS single phase.
Frequency: 47 to 63 Hz.
Four timed relay contacts; both normal open and normal closed provided.
Power consumption:
Characteristics of contacts with a resistive load: . at rest: less than 150 W;
. Maximum voltage : 300 V AC/DC; . maximum load: 1600 W.
. Maximum current : 8 A.
Range of programmable delay: from 0 to 999.99 s. CASE
ANALOG MEASUREMENTS (OPTIONAL): Aluminum, with carrying handle.
DC Current measuring Input, Low WEIGHT AND DIMENSIONS
Measuring range: ± 20 mA.Accuracy: 0.02%. Weight: 18 kg.
DC Voltage measuring input, Low Dimensions:
Measuring range ± 10 V.Accuracy: 0.02%. 170 (h) x 470 (w) x 430 (d) mm.
AC/DC Current measuring Input, High
Measuring range: ± 20 A.Accuracy: 0.2 % D.C.; 0.3% A.C. ACCESSORIES SUPPLIED WITH
AC/DC Voltage measuring input, High THE UNIT
Measuring range ± 250 V.Accuracy: 0.1% D.C.; 0.2% A.C. Protective carrying bag.
INTERFACE CONNECTION Power supply cable.
Serial interface cable.
Type of interface: RS232.
Instruction and maintenance manuals.
Transmission rate: 57.6 kByte/s.

DRTS-6 HP
HIGH PRECISION OPTION
This option has enhanced characteristics with respect to the standard model.This
model is conceived for the test of class 0.2 energy meters.The following table sum-
marizes the performances of the DRTS.6-HP (High Precision) version with respect
to the standard one.

STANDARD DRTS 6 DRTS 6 HP


OUTPUT CURRENT Typical: ± 0.05% ± 0.01% of range Typical: ± 0.02% from 0.1 to 15 A
Maximum: ± 0.1% ± 0.02% of range Maximum: ± 0.05% from 0.1 to 15 A
OUTPUT VOLTAGE Typical: ± 0.05% ± 0.01% of range Typical: ± 0.02% from 50 to 300 V
Maximum: ± 0.1% ± 0.02% of range Maximum: ± 0.05% from 50 to 300 V
PHASE ANGLE Typical: ± 0.02° Typical: ± 0.01°
Maximum: ± 0.05° Maximum: ± 0.02°
POWER Typical: ± 0.05% Typical: ± 0.05%
Maximum: ± 0.2% Maximum: ± 0.1%

ADDITIONAL EXTERNAL AMPLIFIERS FOR DRTS-6

AMI-99
THREE PHASE CURRENT
AMPLIFIER

A PPLICATION
The three phase current amplifier AMI-99
is an additional device to the DRTS.6. DRTS-6
in connection with AMI-99 allows to have 9
currents or 6 currents at 30 A per phase
or three currents at 60 A per phase.
.3.
AMI-99 SPECIFICATION
AMI-99 WITH DRTS-6
RANGE CONNECTION CURRENT POWER Z MAX RESOLUTION Output accuracy: ± 0.1% of the value,
± 0.02% of the range.
A VA Ohm
Distortion: 0.1% total maximum, with any
1 9X DIRECT 6 x 0…15 80 0.35 230 µA load.
3 x 0…30 160 0.18 460 µA
9X 6 x 0...1.5 23 µA Automatic protection for overloads.
2 DIRECT
3 x 0...3 46 µA Angle accuracy: ± 0.1°.
3 9X DIRECT 6 x 0...0.15 2.3 µA
3 x 0...0.3 4.6 µA
4 6 X DRTS-6: PARALLEL 0...30 160 0.18 460 µA
POWER SUPPLY
5 6 X DRTS-6: PARALLEL 0...3 0.18 46 µA Mains power supply: 90 to 264 V a.c.,
6 6 X DRTS-6: PARALLEL 0...0.3 0.18 4.6 µA single phase.
7 3 X PARALLEL 0...60 320 0.09 920 µA Frequency: 47 to 63 Hz.
8 3 X PARALLEL 0...6 0.09 92 µA Power consumption:
9 3 X PARALLEL 0...0.6 0.09 9,2 µA . at rest: less than 100 W;
10 1 X ALL IN PARALLEL 0...180 760 0.023 2.8 mA . maximum load: 1000 W.
WEIGHT AND DIMENSIONS
AMI-99 STAND ALONE
Weight: 16 kg.
RANGE CONNECTION CURRENT POWER Z MAX RESOLUTION Dimensions without the handle:
A VA Ohm 170 (h) x 470 (w) x 430 (d).
1 3 X DIRECT 0...30 160 0.18 460 µA CASE
2 3 X DIRECT 0...3 0.18 46 µA
3 3 X DIRECT 0...0.3 0.18 4.6 µA Case: aluminium, with carrying handle.
4 3 X 2 IN SERIES 0...30 320 0.35 460 µA ACCESSORIES SUPPLIED
5 1 X 3 IN PARALLEL 0...90 480 0.06 1.38 mA WITH THE UNIT
Three independent current sources, with a common neutral. Protective plastic bag.
Automatic range switch and independent range selection. Mains supply cable to DRTS.6.
Interconnecting cable to DRTS.6
Waveform resolution: 28 bit.

AMI-150:
T HREE PHASE HIGH CURRENT AMPLIFIER

A PPLICATION
If high current or high power (or 9 current outputs) are needed for testing old
electromechanical relays or for testing two secondary transformers, the DRTS-6
can control the external high current, three phase amplifier model AMI-50.

AMI-150 SPECIFICATION
AC/DC CURRENT OUTPUTS
POWER SUPPLY
RANGE CONNECTION CURRENT POWER Z MAX RESOLUTION
A VA Ohm Mains power supply: 110 or 230 Vac,
single phase; to be specified at order.
1 3 X DIRECT 0…50 150 0.06 760 µA Frequency: 47/63 Hz.
2 3 X DIRECT 0…25 150 0.24 380 µA Power consumption, maximum load:
3 3 X DIRECT 0…12.5 150 0.96 190 µA 800 W.
4 3 X DIRECT 0…2.5 150 24 38 µA WEIGHT AND DIMENSIONS
5 3 X DIRECT 0…0.05 0.01 24 1 µA Weight: 20 kg.
6 1 X 3 IN SERIES 0…50 450 0.18 760 µA Dimensions: 200 (h) x 470 (w) x 380 (d).
7 1 X 3 IN PARALLEL 0…150 450 0.02 2.28 mA
CASE
Three independent current sources, without a common neutral. Aluminium, with handle.
Accuracy: 0.5% of the range.
ACCESSORIES SUPPLIED
Automatic protection for overloads. WITH THE UNIT
Waveform resolution: 24 bit. Power supply cable.
Frequency range: from 0 Hz to 2 kHz; transient 5 kHz. Connection cable to DRTS-6.
AMI-66
THREE PHASE CURRENT
AMPLIFIER

A PPLICATION
The three phase current amplifier AMI-66 is an
accessory for DRTS-6 for tests that require nine
independent currents at the same time
(two secondary differential transformers).
The three current outputs of AMI-66 can be gen-
erated together with DRTS-6: this also allows par-
alleling current outputs thus increasing output
current and power.

AMI-66 SPECIFICATION Three independent current sources,


without a common neutral.
AMI-66 WITH DRTS-6 Accuracy: 0.1% of the value, ± 0.02%
of the range.
RANGE CONNECTION CURRENT POWER Z MAX RESOLUTION
Automatic protection for overloads.
A VA Ohm
Waveform resolution: 24 bit.
1 3 X DIRECT 0…15 80 0.35 230 µA
Frequency range: from 0 Hz to 2 kHz;
2 3 X DIRECT 0…1.5 0.35 23 µA transient 5 kHz.
3 3 X DIRECT 0…0.15 0.35 2.3 µA POWER SUPPLY
4 1 X 2 IN SERIES 0…15 160 0.71 230 µA
Mains power supply: 110 or 230 Vac,
5 1 X 2 IN PARALLEL 0…30 160 0.18 460 µA single phase; to be specified at order.
Frequency: 47/63 Hz.
AMI-66 STAND ALONE
Power consumption, maximum load:
800 W.
RANGE CONNECTION CURRENT POWER Z MAX RESOLUTION
A VA Ohm WEIGHT AND DIMENSIONS
1 9 X DIRECT 0…15 80 0.35 230 µA Weight: 7 kg.
2 9 X DIRECT 0…1.5 0.35 23 µA Dimensions: 200 (h) x 470 (w) x 360 (d).
3 9 X DIRECT 0…0.15 0.35 2.3 µA CASE
4 3 X 3 IN PARALLEL 0…45 240 0.12 690 µA Aluminium, with handle.
5 3 X 3 IN PARALLEL 0…4.5 0.12 69 µA ACCESSORIES SUPPLIED
6 3 X 3 IN PARALLEL 0…0.45 0.12 7 µA WITH THE UNIT
7 1 X 8 IN PARALLEL 0…120 640 0.04 2 mA Power supply cable.
Connection cable to DRTS-6.

A M I V- 6 6
THREE PHASE CURRENT
A N D V O LTA G E A M P L I F I E R

A PPLICATION
The three phase current and voltage amplifier AMIV-66
is an accessory for the DRTS-6 for tests that require
nine independent currents at the same time (two secondary
differential transformers), or six voltages at the same time
(synchronising devices), or six currents and six voltages.
The three current outputs of AMIV-66 can be generated
together with DRTS-6: this also allows paralleling current
outputs, thus increasing output current and power.

.5.
AMIV-66 SPECIFICATION
THREE PHASE CURRENT GENERATOR
AMIV-66 WITH DRTS-6
Three independent current sources,
RANGE CONNECTION CURRENT POWER Z MAX RESOLUTION with a common neutral.
A VA Ohm
Output frequency: from 0 Hz to 2000 Hz;
1 9 X DIRECT 0…15 80 0.35 230 µA transient 5 kHz.
2 9 X DIRECT 0…1.5 0.35 23 µA Waveform resolution: 28 bit.
3 9 X DIRECT 0…0.15 0.35 2.3 µA Output accuracy: ± 0.1% of the value,
± 0.02% of the range.
4 3 X 3 IN PARALLEL 0…45 240 0.12 690 µA
5 3 X 3 IN PARALLEL 0…4.5 0.12 69 µA Distortion: 0.1% total maximum,
with any load.
6 3 X 3 IN PARALLEL 0…0.45 0.12 7 µA
Automatic protection for overloads.
7 1 X 8 IN PARALLEL 0…120 640 0.04 2 mA
Angle accuracy: ± 0.1°.
AMIV-66 STAND ALONE

RANGE CONNECTION CURRENT POWER Z MAX RESOLUTION


A VA Ohm
1 3 X DIRECT 0…15 80 0.35 230 µA
2 3 X DIRECT 0…1.5 0.35 23 µA
3 3 X DIRECT 0…0.15 0.35 2.3 µA
4 1 X 2 IN SERIES 0…15 160 0.71 230 µA
5 1 X 2 IN PARALLEL 0…30 160 0.18 460 µA

THREE PHASE VOLTAGE GENERATOR Three independent voltage sources,


with a common neutral.
AMIV/66 WITH DRTS-6
Output frequency: from 0 Hz to 2000 Hz;
transient 5 kHz.
RANGE CONNECTION VOLTAGE POWER ZMAX RESOLUTION
V VA Ohm Waveform resolution: 28 bit.
1 6 X DIRECT 0…125 80 195 1.9 mV Output accuracy: ± 0.1% of the value,
2 6 X DIRECT 0…12.5 195 190 µV ± 0.02% of the range.
3 6 X DIRECT 0…1 195 19 µV Distortion: 0.1% total maximum,
4 1 X 4 IN SERIES-PAR. 0…250 320 195 3.8 mV with any load.
5 1 X 4 IN PARALLEL 0…125 320 50 1.9 mV Automatic protection for overloads.
OPTIONAL 300 V OUTPUT Angle accuracy: ± 0.1°.
1 6 X DIRECT 0... 300 80 1125 4.6 mV
2 6 X DIRECT 0... 125 80 195 1.9 mV POWER SUPPLY
3 6 X DIRECT 0... 12.5 195 190 µV Power supply voltage:
4 1 X 4 IN SERIES-PAR. 0... 600 320 195 9.2 mV 90 ... 264 Vac single phase.
5 1 X 4 IN PARALLEL 0... 300 320 50 4.6 mV
Frequency: 47/63 Hz.
Power consumption,
AMIV/66 STAND ALONE maximum load: 1000 W.

RANGE CONNECTION VOLTAGE POWER ZMAX RESOLUTION CASE


V VA Ohm Aluminium, with carrying handle.
1 2 X DIRECT 0…125 80 195 1.9 mV ACCESSORIES SUPPLIED
2 2 X DIRECT 0…12.5 195 190 µV WITH THE UNIT
3 2 X DIRECT 0…1 195 19 µV Power supply cable.
4 1 X 2 IN SERIES 0…250 160 390 3.8 mV
5 1 X 2 IN PARALLEL 0…125 160 97 1.9 mV Interconnecting cable to DRTS-6.
OPTIONAL 300 V OUTPUT Plastic carrying bags.
1 2 X DIRECT 0... 300 80 1125 4.6 mV
2 2 X DIRECT 0... 125 80 195 1.9 mV
WEIGHT AND DIMENSIONS
3 2 X DIRECT 0... 12.5 195 190 µV Weight: 13 kg.
4 1 X 2 IN SERIES 0... 600 160 390 9.2 mV Dimensions:
5 1 X 2 IN PARALLEL 0... 300 160 97 4.6 mV 170 (h) x 470 (w) x 360 (d) mm.
A M V- 6 6
TWO PHASE V O LTA G E A M P L I F I E R

A PPLICATION
The two phase voltage amplifier AMV-66
is an accessory for the DRTS-6, for tests
that require six voltages at the same time
(synchronising devices).

AMV-66 SPECIFICATION
TWO PHASE VOLTAGE GENERATOR
AMV-66 WITH DRTS-6
Three independent voltage sources,
RANGE CONNECTION VOLTAGE POWER ZMAX RESOLUTION with a common neutral.
V VA Ohm Output frequency: from 0 Hz to 2000 Hz;
1 6 X DIRECT 0…125 80 195 1.9 mV transient 5 kHz.
2 6 X DIRECT 0…12.5 195 190 µV Waveform resolution: 28 bit.
3 6 X DIRECT 0…1 195 19 µV
Output accuracy: ± 0.1% of the value,
4 1 X 4 IN SERIES-PAR. 0…250 320 195 3.8 mV ± 0.02% of the range.
5 1 X 4 IN PARALLEL 0…125 320 50 1.9 mV
OPTIONAL 300 V OUTPUT Distortion: 0.1% total maximum,
with any load.
1 6 X DIRECT 0... 300 80 1125 4.6 mV
2 6 X DIRECT 0... 125 80 195 1.9 mV Automatic protection for overloads.
3 6 X DIRECT 0... 12.5 195 190 µV Angle accuracy: ± 0.1°.
4 1 X 4 IN SERIES-PAR. 0... 600 320 195 9.2 mV
5 1 X 4 IN PARALLEL 0... 300 320 50 4.6 mV POWER SUPPLY
Power supply voltage: 90 ... 264 Vac
AMV/66 STAND ALONE single phase.
Frequency: 47/63 Hz.
RANGE CONNECTION VOLTAGE POWER ZMAX RESOLUTION Power consumption, maximum load:
V VA Ohm 500 W.
1 2 X DIRECT 0…125 80 195 1.9 mV
2 2 X DIRECT 0…12.5 195 190 µV
CASE
3 2 X DIRECT 0…1 195 19 µV Aluminium, with carrying handle.
4 1 X 2 IN SERIES 0…250 160 390 3.8 mV ACCESSORIES SUPPLIED
5 1 X 2 IN PARALLEL 0…125 160 97 1.9 mV WITH THE UNIT
OPTIONAL 300 V OUTPUT Power supply cable.
1 2 X DIRECT 0... 300 80 1125 4.6 mV
2 2 X DIRECT 0... 125 80 195 1.9 mV Interconnecting cable to DRTS-6.
3 2 X DIRECT 0... 12.5 195 190 µV WEIGHT AND DIMENSIONS
4 1 X 2 IN SERIES 0... 600 160 390 9.2 mV
Weight: 7 kg.
5 1 X 2 IN PARALLEL 0... 300 160 97 4.6 mV
Dimensions:
170 (h) x 230 (w) x 360 (d) mm.
OPTIONAL ACCESSORIES

IO-6432 IO-6432
SPECIFICATION
D I G I TA L I N P U T A N D O U T P U T E X PA N S I O N
INPUTS
A PPLICATION Number of inputs: 64, by 4 groups of 16.
Inputs: logic, voltage from 5 to 130 V d.c.;
The option IO-6432 increases the number of logic inputs and outputs that can be maximum load current 3 mA.
monitored by the DRTS-6.The option adds to inputs and outputs that are located Input and output groups are isolated
in the DRTS-6.The IO-6432 is fitted internally in the DRTS-6 unit. from each other; they are also isolated
from the rest of the instrument, from the
mains supply and from the ground.

.7.
It is possible to separately program each input as Normally Open or Normally Dimensions: 150 x 100 x 240 mm.
Closed or Disabled. Case: plastic case.
It is possible to separately program the timer stop of each programmed input as
Trip or Reset. SHA-1 ENERGY METERS
Logic input time measurement resolution: 1 ms. UNIVERSAL SCANNING
Logic input time measurement accuracy: 2 ms. HEAD
OUTPUTS A PPLICATION
Number of outputs: 32, in 4 groups of 8. SHA-1 is a scanning head that eases the
Type of outputs: open collector; maximum voltage 130 V; test of energy meters. It is an universal
minimum current capability 15 mA. scanning head because it can be used
both with LED impulse electronic meters
It is possible to separately program each logic output as Normally Open and Ferraris rotating disk meters.
or Normally Closed. With rotating disk the sensor uses a
It is possible to separately delay each logic output with respect to currents green light beam that optimizes
and voltages. the recognition of any type of mark.
Logic output time accuracy: 1 ms. With LED recognition the following
specification applies:
OPTION OUT32 FOR THE IO6432 OPTION . Impulse duration: more than 60 us;
. Impulse frequency: less than 500 Hz;
IO6432 outputs drive the load to zero. If the output must be driven with . Duty cycle: 50%;
the voltage, or if the current is not sufficient, it is available the module OUT32, . Light wavelength: 500 to 960 nm (red).
that has the following characteristics:
Inputs: 32, from IO6432 of DRTS. The option includes:
.A support to keep the scanning head in
Outputs: 32 relay contacts (both ends), with the following characteristics. front of the energy meter;
.Vmax: 250 V; .The cable, 2 m long, from the scanning
. Imax: 0.5 A; head to the DRTS-6;
. Outputs protected against over-voltage; .The power supply transformer, for the
.Time delay: less than 10 ms. power of 220 Vac, to supply the scanning
Connection to DRTS: with a cable I m long, provided. head.
Lights that turn on when the relay is closed. APPLICABLE STANDARDS
Output connection: by two 50-way connectors. ELECTROMAGNETIC COMPATIBILITY
Power supply: from the mains; 220 V 50 Hz. Directive no. 89/336/CEE dated
Weight: 3 kg. May 3, 1989, modified by the directive
92/31/CEE dated May 5, 1992.
Dimensions: 25 x 19 x 11 cm. Applicable Standards:
Case: plastic, with graved front face. EN 50081-2; EN 50082-2; EN 55011;
EN 61000-3-3; EN 50082-2; ENV 50140;
OPTIONAL GPS SYNCHRONIZER ENV 50141; ENV 50204; IEC 1000-4-2;
IEC 1000-4-4; IEC 1000-4-6;
A PPLICATION IEC 1000-4-8.
External module for synchronization of two sets via GPS system, for end to end LOW VOLTAGE DIRECTIVE
test of differential relays. Directive n. 73/23/CEE, modified by the
1 digital output 0-24 Vdc, for synchronisation. directive 93/68/CEE.
1 selector to program the following pulse intervals: 5 s; 10 s; 20 s; 30 s; 40 s; 60 s. Applicable standards, for a class I
instrument, pollution degree 2,
Maximum timing error with respect to nominal: 2 µs. Installation category II:
Two test sets synchronized with GPS produce the maximum error of 50 µs. CEI EN 61010-1.
In particular:
Power supply: 110/220 Vac. Operating temperature: 0 - 50°C;
The option includes the antenna and connection cables. storage: - 25°C to 70°C.
Relative humidity :
Weight: 1.7 kg. 5 - 95% without condensing.

CEE Relays Ltd.


87C Whitby Road
Slough
SL1 3DR
T: 01753 576477
F: 01753 825661
Web: www.ceerelays.co.uk

You might also like