Catalogo Da Chave de Nivel Do Sistema Bilge Engine Room
Catalogo Da Chave de Nivel Do Sistema Bilge Engine Room
com
e-mail: [email protected]
MAGNETIC FLOAT LEVEL SWITCH Tel: 886-2-22696789 Fax: 886-2-22686682
PRINCIPLE
The single unit or multiple reed switch units are When the float internal magnet approaches the
housed tightly in stainless steel or engineering reed switch, it will actuate the reed switch contact
plastic stem, and the permanent magnet is point to create an open or close circuit. We can
sealed into the middle of the specified float apply such on-off output signals to reach liquid
ball(s). You can mount the float ball to penetrating level controlling and monitoring purpose.
through the stem, then the liquid buoyancy will The figures below show the float orientations on
deliver the float ball up and down at the specified N.O. (Normal Open) and N.C. (Normal Close).
position by graduating rings.
Float ball
Reed switch
NO NO
NC NC
Permanent
magnet
FEATURES
Multiple points measuring, multiple level points The housing protection rating up to IP65.
are available for custom-built.
Rugged construction and multiple options for
It is used the magnet to actuate the reed switch materials from engineering plastics as PVDF,
without any extra electric power source. PP, PVC, and stainless steels as SUS304,
Each reed switch is durable for operation life SUS316, float switches can be applied to
reaching 2 million times. versatile applications in chemical corrosion
of acidity and alkalinity liquid, solvents or oil
All output signal wiring are simplified in same fuels.
junction box (housing) to economize the external
wiring construction. The reed switch and lead wire are isolated
absolutely with liquids. All stainless steel
FC(D) type magnetic float level switches are more
switches are applicable to high pressure and
economical in budget than other level switches by
high temperature performances.
comparison in multiple points.
1
FlneTek
INTRODUCTION
APPLICATIONS
Shipbuilding Industry, Generator Facilities, Petrochemical Industry, Food/Beverage Industry,
Waste Water/Water Purified Facilities, Electronic Industry, Dyeing And Finishing Industry,
Chemical Industry, Rubber/ Plastic Industry, Hydraulic.
SPECIFICATION
- 20°C~120°C
SUS304 (200°C Max.) 10~ 30kg/cm2
- 20°C~120°C
SUS316 10~ 30kg/cm2
(200°C Max.)
2
CHEMICAL RESISTANCE
3
FlneTek
Excellent Good Fair Corroded
Temp Plastic Rubber Stainless
Chemical
% BC PVC PP PVDF PTFE NBR 304 316
Citric Acid 10 40 104
C6H8O7 10 80 176
Gasoline 10 40 104
10 80 176
Diesel Fuels 40 104
80 176
Ethyl Alchol 40 104
Pure
C2H5OH 80 176
Formic Acid 90 40 104
HCOOH 80 176
Hydrofluric Dilute 40 104
Acid Dilute 80 176
HF 30 40 104
30 80 176
40 40 104
40 80 176
50 40 104
50 80 176
Hydrogen 5 40 104
peroxide 5 80 176
H2O2 20 40 104
20 80 176
30 40 104
30 80 176
50 40 104
50 80 176
90 40 104
90 80 176
Isopropyl Alcohol 40 104
(CH3)CHOH
Pure
80 176
Kerosene 40 104
80 176
Methyl Alcohol 40 104
CH3OH 80 176
Methyl Ethyl Ketone 40 104
CHCO3 CH 2 5 80 176
Potassium Chromate 40 104
KCrO
2 4 80 176
4
FlneTek
CONTACT PROTECTION CIRCUITS
INDUCTIVE LOADS
When using a reed switch with inductive Such high induced voltage (transients) may
loads such as motors, relays, solenoids, etc., cause damages to the reed switch or
The contact will be subjected to a high significantly reduce its life.
induced voltage during opening of the Therefore, protective circuits such as: RC
contact (load circuit). (snubber), varistors or clamping diodes are
recommended.
. It is prohibited to connect directly with any solenoid valve, motor or magnetic switch.
CAPACITIVE LOADS
When using a reed switch with capacitive Therefore, protective circuits such as:
loads such as capacitors, incandescent lamps surge suppressors or current limiting resistors
or long cables, the contact will be subjected to are recommended.
a high surge (inrush) current.
5
FlneTek
HOUSING SPECIFICATION
B 128
C 128 D Explosion-proof
f118 f118 f113
1/2" or
3/4"NPT
107 107 108
1/2"PF 1/2"PF
Material : Aluminum
Enclosure : NEPSI Ex d IIB T3~T6
Material : Aluminum Material : PP+Fiber ATEX II 2G EEx d IIB T3~T6
Enclosure : IP65 Enclosure : IP65 ATEX II 2D IP65 T3~T6
Max.Temp.: -20BC ~200BC Max.Temp.: -20BC ~80BC Max.Temp.: -20BC ~200BC
E G H
88 80x75 f70
57
84
70
PG16 1/2"PF
1/2"PF
K Explosion-proof
100
L Explosion-proof M Explosion-proof
80 f70
f90
80 1/2"NPT
100 1/2"NPT
3/4"NPT 80
1/2"NPT
3/4"NPT Material : SUS316
Material : Aluminum Material : Aluminum Enclosure : NEPSI Ex d IIB T3~T6
Enclosure : CESI 03 ATEX 108 Enclosure : CESI 03 ATEX 108 ATEX II 2G EEx d IIB T3~T6
II 2G EEx d IIC T6 II 2G EEx d IIC T6 ATEX II 2D IP65 T3~T6
Max.Temp.: -20BC ~100BC Max.Temp.: -20BC ~100BC Max.Temp.: -20BC ~200BC
*Recommend for flow switch used *Recommend for side float sw. used
6
FlneTek
FLOAT SPECIFICATIONS
MODEL TYPE fAxBxfC S.G. Max. Pressure Weight Material/Color Max. Temp.
2
(kg/cm ) (g) (LC)
C
S7 3032839.5 E>0.82 30 8 SUS 316 200
white
P1 25315310 E>0.65 4 3.5 PP / 80
A black
white
P2 25325310 E>0.55 4 5 PP / 80
B black
A
F2 42344314 E>0.63 5 18.5 PP 80
1. Temperature: PVDF Max. 120BC, 4. Chemical: Please use plastic float for acid/
PP Max. 80BC, alkaline corrosion of chemical
SUS304/ 316 Max. 200BC applications. PVDF float is noted
for high temperature cases.
2. Pressure: SUS304/ 316 Float, Max. 35kg/cm2
Engineering plastic, Max. 5kg/cm2 5. Benzine: Please choose stainless steel floats
to apply in any gasoline, fuel oil,
3. Viscosity: Please choose smaller S.G. with petroleum application.
greater diameter floats to cope with
high viscosity liquid applications. 6. S.G.: The float S.G. Must be smaller than the
liquid, otherwise, the liquid buoyancy
can not deliver the float upword.
7
FlneTek
ORDER SPECIFIED
The magnetic level switch can be done as per independent float actuating position, please
customer's specified technical data such as refer the order information to define the
the flange, thread, housing, float ball diameter, application specifications. A single ball driving
float ball number, the float traveling up or down multiple actuated points is available to apply
actuated position by N.C. or N.O. output, the on the order form.
total float working distance (L) or each
Example: FD B HM 7 S6 3 0405
Housing Type Connection Stem (Tube) Type Float Type Float Number Total Float Working Distance
It is requested the minimum interval for a single A= Minimum distance from the mounting
ball driving dual actuated positions (D) or position to the highest actuation level.
neighboring two balls (B), or from the bottom to B= Minimum distance between any two
the lowest ball interval (C) or from the mounting actuation levels.
position to the first ball (A), otherwise, there will
be some magnetic mutually interference involved C= Minimum distance from end of the lowest level.
by insufficient interval. To ensure the defined D= Minimum distance between two actuation levels
distance, please see the data below: by one float.
E= Screw length
FLOAT TYPE S1 S2 S3 S4 S5 S6 P2 P3 F1
A(mm) 25 32 40 39 50 70 30 50 50
B(mm) 50 64 82 78 99 136 63 85 99
C(mm) 25 32 40 39 50 70 30 43 50
D(mm) 30 40 55 50 65 70 30 45 65
E SCREW
(mm)
14 1/2"PT
16 3/4"PT
19 1"PT
22 1-1/4"PT
22 1-1/2"PT
25 2"PT
28 2-1/2"PT
32 3"PT
8
FlneTek
HOW TO MAKE YOUR ORDER
F
Length: mm (total)
Quantity of float
Stem
Code size Material
1: f 8 SUS304 or SUS316
2: f 8 PVC
3: f 9.5 SUS304 or SUS316
4: f 12.7 SUS304 or SUS316
5: f 17.2 PP
6: f 16 PVDF
7: f 17.2 SUS304 or SUS316
8: f 12.7 PP
9: f 12.7 PVC
Connection Type
D: Metal (Stem)
9
FlneTek
ANTI-CORROSION SCREW TYPE / FLANGE TYPE
1/2"PF 1/2"PF
130 130
2"PT 2"PT
NO 1 NO 1
NC mm NC mm
2
2 NO
NO
NC mm
NC mm
L=
mm NO 3
L= 3 NC mm
mm NO
NC mm
NO 4
NC mm
NO 4
NC mm 45
60
f17.2
Wetted Parts PVDF f 48 Wetted Parts PP
f16
f 48
1/2"PF 1/2"PF
Type
Housing Type 145 145
Flange Flange
2"x10kg/cm2 2"x10kg/cm2
FC C (FQ) 6 F1 4
1 NO 1
NO
NC NC mm
mm
2
2 NO
NO NC mm
NC mm
Connection Pipe Float Float
Flanges Diameter Type Quantity
L= mm NO 3
L= NC
FQ=2" F4=PVDF mm NO 3 mm
6= f16 f48x60 1~ 4 NC mm
PT
FQ=2" P3=PP NO 4
5= f17.2 1~ 4
PT f48x45 4
NC mm
NO
FN=2" F4=PVDF NC mm 45
6= f16 1~ 4
10kg/cm 2 f48x60
60
FN=2" P3=PP f17.2
10kg/cm 2 5= f17.2 1~ 4 f 48
f48x45 Wetted Parts PVDF Wetted Parts PP
f16
flange/thread f 48
are available,too.
10
FlneTek
STANDARD FLANGE TYPE
Type
FD B (EM) 3 S2 4 Type
FD B (FM) 4 S3 4
128 128
1/2"PF 1/2"PF
107 107
Flange Flange
1-1/2"x 5kg/cm2 2"x 5kg/cm2
NO 1 NO 1
NC mm NC mm
2
NO 2
NC mm NO
NC mm
3
L= NO
mm NC mm
NO 3
L=
mm NC mm
NO 4
NC mm
38 NO 4
NC mm
f9.5 55
f 41
f12.7
f 45
1/2"PF 1/2"PF
Type
107 107
Housing Type
Flange Flange
2"x 5kg/cm
2 3"x 5kg/cm2
FD B (HM) 7 S6 4
NO 1
NC mm
NO 1
NC mm
2
NO
NC mm
2
Connection Pipe Float Float NO
3 NC mm
Flanges Diameter Type Quantity L=
mm
NO
NC mm
EM=1-1/2" S2=
3= f9.5 f41x38 1~ 4
5kg/cm 2 NO 4
NC mm
FM=2" S3= 3
4= f12.7 1~ 4 52 L= NO
5kg/cm 2 f45x55 mm NC mm
FM=2" S4=
4= f12.7 1~ 4 f12.7
5kg/cm 2 f52x52 f 52
HM=3" S6=
5kg/cm 2 7= f17.2 f75x108
1~ 4 4
NO
NC mm
108
f17.2
f 75
11
FlneTek
STANDARD SCREW TYPE
Type
FD B (EQ) 3 S2 4 Type FD B (FQ) 4 S3 4
128 128
1/2"PF 1/2"PF
107 107
1-1/2"PT 2"PT
NO 1
NO 1
NC mm NC mm
2
NO
NC mm 2
NO
NC mm
3
L= NO
mm NC mm
L= NO 3
mm
NO 4 NC mm
NC mm
38
NO 4
NC mm
f9.5
f 41 55
f12.7
f 45
Type
FD B (FQ) 4 S4 4 Type
FD B (HQ) 7 S6 4
Order information 128 128
1/2"PF 1/2"PF
Type
Housing Type 107 107
2"PT 3"PT
FD B (HQ) 7 S6 4 NO 1
NC mm
NO 1
NC mm
2
NO
NC mm
EQ=1-1/2" S2=
3= f9.5 f41x38 1~ 4 4
PT NO
NC mm
FQ=2" S3=
4= f12.7 1~ 4 52 NO 3
PT f45x55 L=
mm NC mm
HQ=3" S6=
PT 7= f17.2 f75x108
1~ 4
NO 4
NC mm
108
f17.2
12 f 75
FlneTek
SCREW TYPE / FLANGE TYPE
93 93
1/2"PF 1/2"PF
Flange Flange
84 84
1-1/2"x5kg/cm2 1-1/4"x5kg/cm2
NO 1
NO 1
NC mm
NC mm
2
NO
L= NC mm
mm
2
L= NO
3
mm NC mm NO
NC mm
NO 3 28
NC mm
f8
38
f28
f9.5
f 41
Type
FD E (EQ) 3 S2 3 Type
FD E (DQ) 1 S1 3
Order information
Type 93 93
Housing Type
1/2"PF 1/2"PF
84 84
FD E (3Q) 1 S1 3 1-1/2"PT 1"PT
NO 1
NO 1
NC mm
NC mm
2
NO
L= NC mm
2 mm
Connection Float NO
Pipe Float L=
mm NC mm NO 3
Flanges Diameter Type Quantity NC mm
NO 3 28
EM=1-1/2" S2= NC mm
3= f9.5 f41x38 1~ 3 f8
5kg/cm 2 38 f28
3M=1-1/4" S1=
1= f8 1~ 3 f9.5
5kg/cm 2 f28x28
f 41
EQ=1-1/2" S2=
3= f9.5 1~ 3
PT f41x38
S1=
DQ=1"PT 1= f8 f28x28
1~ 3
13
FlneTek
ENCLOSURE EXPLOSION PROOF
3/4"NPT 3/4"NPT
Type
Housing Type 120 120 Flange
Flange
2"x5kg/cm2 3"x 5kg/cm2
FD - K - HM - 7 - S6 - 4 1
NO
NC mm
NO 1
NC mm
2
NO
NC mm
2
NO
Connection Pipe Float Float L= NO 3 NC mm
Flanges Diameter Type Quantity mm NC mm
EM=1-1/2" S2=
3= f9.5 f41x38 1~ 4
5kg/cm 2 NO 4
NC mm
3
FM=2" S3= 52 L= NO
4= f12.7 1~ 4 mm NC mm
5kg/cm 2 f45x55
FM=2" S4= f12.7
4= f12.7 1~ 4
5kg/cm 2 f52x52 f52
HM=3" S6=
5kg/cm 2 7= f17.2 f75x108
1~ 4 NO 4
NC mm
108
f17.2
f 75
SCREW TYPE Type FD K (FQ) 4 S4 4 Type FD K (HQ) 7 S6 4
100 100
f90 f90
3/4"NPT 3/4"NPT
Type
Housing Type 120 120
2"PT
3"PT
FD - K - HQ - 7 - S6 - 4 NO 1
NC mm
NO 1
NC mm
2
NO
NC mm
EQ=1-1/2" S2=
3= f9.5 f41x38 1~ 4
PT NO 4
NC mm
FQ=2" S3=
4= f12.7 1~ 4 52
PT f45x55 L= NO 3
mm NC mm
FQ=2" S4= f12.7
4= f12.7 1~ 4
PT f52x52 f 52
HQ=3" S6=
PT 7= f17.2 f75x108
1~ 4
NO 4
NC mm
108
f17.2
14 f 75
VERTICAL ADJUSTMENT TYPE
This is a special design for some liquid Applicable at tank interior pressure under
applications requiring monitoring different 5 kg/cm2.
actuation levels frequently. The user needs only to Standard specification 80BC, special order
loose the hexagon nut, then remove the mounted of max. 200BC available.
screw/ flange up or down to achieve the Switch contact: 20W/150Vac /250Vdc SPDT
actuated level position adjustment.
50W/300Vac /350Vdc SPST
60W/220Vac /500Vdc SPST
60W/400Vac /1000Vdc SPDT
Customer specified flange/ screw
acceptable.
FD E (EJ) 4 S4 1 FD E (EK) 3 S2 1
FD E (EJ) 4 S4 1
15
FlneTek
TEST ROD GL Marine Approval 50885-04HH
Function: Material:
When the Test Rod is attached to a magnetic float 1. Rod Connection: Bronze
level switch, user could test the performance of 2. Compressed Spring: Stainless Steel
the magnetic switch directly by pulling the handle 3. Positioning Clip: Stainless Steel
of the test rod on the top of the switch. 4. Test Rod Stem: Stainless Steel
FD......T
FDB-4000
HEX27 45
Connecting flange 1
Min. 3"x5kg/cm2
2
f8
88
16
FlneTek
MARINE GRADE APPROVAL
RHM DM 4 S3 1 RSM FM 4 S3 1
f70 f70
1/2"NPT 1/2"NPT
80 80
200
2"x5kg/c
L(Max. 2M)
L(Max. 2M)
C-C
17
FlneTek
ENCLOSURE EXPLOSION PROOF TYPE
1/2"NPT 1/2"NPT
1/2"NPT
108 108
80
Flange Flange
3"x 5kg/cm2 Flange
2"x 5kg/cm2 3"x 5kg/cm2
NO 1
NC mm
NO 1
NO 1
NC mm NC mm
2
NO
NC mm
2
NO 2
mm NO
3 NC
L= NO NC mm
mm NC mm
NO 4
NC mm
NO 3
L= NO 3
52 mm NC mm L=
mm NC mm
f12.7
f 45
NO 4
NO 4
NC mm
NC mm
108 108
f75 f75
1/2"NPT 1/2"NPT
1/2"NPT
108 108
80
2"PT 3"PT
3"PT
NO 1
NC mm
NO 1
NO 1
NC mm NC mm
2
NO
NC mm
2
3 NO 2
L= NO mm NO
mm NC mm
NC
NC mm
NO 4
NC mm
52 NO 3
3
L= NC L= NO
mm mm
mm NC mm
f12.7
f 45
NO 4
NO 4
NC mm
NC mm
108 108
f17.2 f17.2
f 75 f 75
18
FlneTek
HOW TO MAKE YOUR ORDER
Quantity of float
Stem
Code size Material
1: f 8 SUS304 or SUS316
3: f 9.5 SUS304 or SUS316
4: f 12.7 SUS304 or SUS316
5: f 17.2 PP
6: f 16 PVDF
7: f 17.2 SUS304
Connection Type
Housing Type
D: Aluminum (Explosion-proof) Size for flange or screw Pressure range or other
EEx IIB T3~T6
M: 5kg/cm2 JIS
N: SUS304 or SUS316 A: 3/8" (10A) I: 4"(100A) N: 10kg/cm2 JIS
(Explosion-proof) B: 1/2" (15A) J: 5"(125A) O: 150Lbs ANSI
EEx IIB T3~T6 C: 3/4" (20A) K: 6"(150A) P : 300Lbs ANSI
D: 1" (25A) S: Others Q: PT
E: 1-1/2"(40A) 1: 1/8" R: PF
F: 2" (50A) 2: 1/4" T: BSP ( DIN )
G: 2-1/2"(65A) 3: 1-1/4"(32A) U : NPT
H: 3" (80A) V : GAS
S : Others
W: PN10 (10Bar)
X: PN16 (16Bar)
Y: PN25 (25Bar)
Z: PN40 (40Bar)
Certified by GL, ABS Marine grade J : Adjustment screw
are available. (Please see page 17) K: Adjustment flange
19
FlneTek
TYPICAL WIRING DIAGRAMS
The "N.O." Means normally opened circuit of the reed switch (off) in lower liquid
level. As the float moves up to the specified higher level, the circuit closed (on).
The "N.C." Means normally closed circuit of the reed switch (on) in lower liquid
level. As the float moves up to the specified higher level, the circuit closed (off).
20
FlneTek
INSTALLATION
21
FlneTek
CONNECTION DIAGRAMS
NO C NC
Means that the NC-C circuit will be close while liquid level lower than the float ball,
by mark of "¯ON".
NO C NC
Means that the NO-C circuit will be close while liquid level higher than the float ball,
by mark of "-ON".
NO C NC
Means that the NO-C circuit will be close while liquid level higher than the float ball,
and NC-C circuit will be close while liquid level lower than the float ball.
Please screw the housing cap tightly and fix the conduit outlet, it will reinforce the housing
performance against the moisture and direct water. (f8mm multiple cord is recommended
for wiring)
If the end user is intended to adjust the actuation level position independently, please move
the float ball(s) position as well as the interior reed switches, otherwise, it will appear an
error or no signal.
22
FlneTek