Datasheet
Bently Nevada Machinery Condition Monitoring 172179 Rev. AN
Description
ADRE Sxp Software and the 408 DSPi (Dynamic Signal
Processing Instrument) make up a highly scalable system for
multi-channel signal processing and data acquisition.
Unlike other general-purpose computer-based data
acquisition systems, ADRE Sxp and the 408 DSPi are
specifically designed for real-time highly parallel signal
processing and presentation. This extremely versatile system
incorporates the functionality of many types of
instrumentation, such as oscilloscopes, spectrum analyzers,
filters, signal conditioners, and digital recorders into a single
platform. The system is designed specifically for secure
corporate network environments, allowing it to operate
remotely across a LAN/WAN, or store data in full “stand-
alone” mode without an additional/external computer.
Additional equipment is seldom, if ever, needed. The system’s
real-time display capability permits it to continuously display
data independently of data being stored to permanent
memory. For established ADRE system users, ADRE Sxp also
supports all previous ADRE for Windows databases.
An ADRE Sxp data acquisition system consists of:
l 408 Dynamic Signal Processing Instrument(s).
l ADRE Sxp client software, ADRE Quick Configuration
software.
l A computer system capable of running ADRE Sxp
software.
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
The 408 DSPi is fully portable or can be rack signal processing and sampling parameters
mounted allowing convenient operation in test can be changed “on-the-fly” without
stands, on-site, or at remote locations. The 408 interrupting data collection.
DSPi’s highly configurable design supports
The 408 DSPi architecture provides flexible
virtually all standard and non-standard input
hardware configuration. Users can insert
types including both dynamic transducer
sampling cards into the chassis as required.
signals (such as those from proximity probes,
Slots 1 through 4 support all standard sampling
velocity transducers, accelerometers, force
cards. Slot 5 is intended specifically for the
hammers, dynamic pressure sensors), and
Digital Replay card as well as future option
static signals (such as process variables from
cards.
transmitters and distributed control systems).
For rotating machinery applications, users can The standard Dynamic Sampling and Speed
provide a Keyphasor or other speed input Input/Trigger cards provide full support for
signal (such as that from a magnetic or optical structural analysis and impact testing. Data
transducer) to drive synchronous sampling can be analyzed natively or exported to 3rd
and order tracking. For structural analysis party applications if desired.
needs, impact testing using force hammers is
supported. The system also supports multiple The 408 DSPi front panel controls and displays
triggering modes for automated data basic functions and data. Users can directly
acquisition, allowing you to use the system as a initiate manual samples and triggering from
data or event logger without an operator the front panel without using ADRE Sxp
present. software. The front panel LEDs indicates
sampling and trigger status and activity. Users
The Client-Server architecture allows multiple can download multiple sampling
software clients to operate and simultaneously configurations to the 408 DSPi and later select
view data from single/multiple 408 DSPi them for use from the front panel.
systems simultaneously, permitting users to
independently view data in the fundamental 8-Channel Dynamic Sampling
measurement units of their choice. Software Card (168905 – AA)
installation and configuration are quick and
easy, allowing mass configuration of multiple The 8-channel dynamic sampling card is an
channels with minimal user intervention. extremely powerful and flexible signal
Configuration templates and software further processing engine. Along with the analog front-
simplifies the process, allowing the user to end conditioning, the user can configure most
install the software, produce a configuration, transducer inputs, with positive or negative
and begin capturing data in minutes. bias, while maintaining maximum signal input
range. An array of DSP processors and 24-bit
408 DSPi Overview ADCs provide maximum resolution. Input
signals can be either AC or DC coupled, and
Each 408 DSPi supports up to 4 sampling cards
users can independently define upper and
for up to 32 channels of data acquisition. The
lower input voltage levels along with full-scale
408 DSPi base system uses internal clocks and
range and transducer scale factor.
simulated speed/Keyphasor signals to support
both asynchronous and synchronous sampling The sampling card can provide a variety of
for all channels. Speed Input/Trigger cards data depending on the configuration and user
support up to 3 independent speed input needs. Each channel can provide multiple
channels for external speed inputs. Each Speed “static” variables including:
Input/Trigger card uses 1 available slot, and the
408 DSPi can use a maximum of 2 Speed l Direct amplitude.
Input/Trigger cards simultaneously providing l Bandpass amplitude.
up to 6 physical speed inputs and 6 simulated
speed inputs. The user can assign any speed
input (KPH) to any channel in a 408 DSPi. Most
2/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
l 1X and 2X Amplitude and Phase, and up Each channel also includes a buffered output,
to 4 additional user defined nX vectors allowing the user to select either raw,
including amplitude and phase. conditioned analog, or TTL outputs. The
buffered outputs are independent of the signal
l Average & instantaneous gap or bias
being used for processing.
voltages.
l Multiple speed values. Digital Replay Card
l Adate/time stamp. (168907 – AA – BB-CC)
In addition to the static data, each channel can The Digital Replay Card provides simultaneous
provide up to 4 user-defined dynamic synchronous and asynchronous internal digital
waveforms. Users can configure waveforms for reprocessing and playback of all channels in
simultaneous Synchronous and/or the 408DSPi. The replay card maintains
Asynchronous sampling, with different exceptional accuracy and precision in the
sampling rates and/or frequency spans. The signal reprocessing that far surpasses the
sampling card supports up to 2 different capabilities of other equipment and
synchronous sampling rates simultaneously. reprocessing techniques. The digital replay
Time-Synchronous Averaging can also be card can play back raw data for all channels
enabled for all synchronous waveforms. In simultaneously including Keyphasor/speed
addition, the card can also sample and store and dynamic sampler inputs. Users can modify
the raw time-continuous data for each all sampling parameters on a KPH channel
channel. All channels within the system are when replayed, and fully manage and re-
always sampled simultaneously, are condition the gain, inversion, clamping, and
synchronized, and are initiated based on a set other characteristics of Keyphasor signals. This
of user defined events. provides the ability to control triggering edges
and thresholds as reprocessing and analysis
3-Ch Speed Input/Trigger Card
requires. On standard dynamic channels, users
(168906 – AA) can modify most sampling parameters. As an
The 3-channel speed input/trigger card example, users may add or modify waveform
supports a variety of transducer inputs and assignments, variable generation, filtering
signal conditioning needs including; proximity, options, frequency span, and Keyphasor
magnetic, optical, and laser pickups. assignments that did not exist in the original
Transducer power for both optical pickup and ± configuration reprocessing the data.
24Vdc proximity is also available if needed. For Additionally, users may add or modify all
impact testing applications, the force hammer sampling criteria and triggering parameters.
output can be connected directly to this card Full scale range, coupling, and transducer type
providing level triggering and full dynamic cannot be altered for standard dynamic
waveform capture. The card integrates a rich channels. The Digital Replay card occupies Slot
set of configurable analog signal conditioning #5 of the 408 DSPi and does not reduce the
tools including: input gain, voltage clamping, number of channels available for data
inversion, rising or falling edge trigger, collection.
auto/manual threshold, and hysteresis. The With the addition of Analog Output Replay Card
user can associate a programmable speed the user may send up to 32 channels of
input (Keyphasor) multiplier/divider for each recorded signals through data ports to auxiliary
channel independently, define discrete values equipment. These signals are analog
for events per revolution, or, a final ratio, recreations of the original data observed by
whichever is more convenient. Each channel ADRE. The Replay Module can be ordered with
can have up to three separate “stages” of or without the Analog Output Replay Card.
multiplier/divider ratios. Trigger/speed input Existing Replay Cards can be modified to
channels provide full dynamic sampling, include the Analog Output feature by sending
complete with static and waveform data, the cards to Product Repair at Bently Nevada.
available for real-time viewing and storage.
3/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
4/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
AC 0.7 to 10 V
Specifications Configurable
Full Scale
408 DSPi Range
DC 0.35 to 50 V
Typical specifications are provided Configurable
for a temperature of +25 °C ± 3 °C Full Scale
(+77 °F ± 5.4 °F ) except where Range
noted.
Status Boot, Selftest, OK/Not OK,
Indication Activity, A/D over range
Data Storage Internal-480GB or 960GB
Capacity Direct Measurement Accuracy
Communication Dual 1000/100Mb RJ45
Ethernet Ports Filter values @ 0 db points unless
Protocol-TCP/IP specified otherwise.
DHCP or Fixed IP
addressing
LAN/WAN compatible 2 Dynamic Sampling Card
Amplitude vs. Frequency
Internal Cloc Battery-Backed Real-Time Cumulative Error
clock (RTC) accuracy is ±
2 seconds / month
Non-RMS, Non-Integrated Amplitude
Signal Conditioning-General AC Coupled – 1.6 Hz to 50 kHz
Hi Mode ± 1.25% of Full Scale Range2
8 Channel Dynamic Sampling Card
AC Coupled- N/A
Slot Position Slots 1 through 4 Low Mode
24 Bit A/D converters DC Coupled – 1 Hz to 50 kHz
Hi Mode ± 1% of Full Scale Range2
Input Impedance
± .011V below 1 V pp
Single Ended 742kΩ
Inputs
± .011V below 1 V pp
Single-ended 8 Non-Integrated, RMS Amplitude
Differential 4 Acceleration 10 Hz to 50 kHz
AC/DC ± 1% of Full Scale Range2
4-20 mA 8
Coupled Hi
Maximum -25 to 25 V Mode
Signal Input
Range:
5/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
Invalid KPH or High Mode – 2 sec sliding Options HPF < 10 Hz ( 2 Pole )
No KPH window HPF ≥ 10 Hz ( 2, 4, 6, 8 Pole)
present Low Mode – 12 sec sliding LPF ≥ 10 Hz ( 2, 4, 6, 8 Pole)
window
100ms update rate -3db Corner HPF & LPF-1 Hz Increments,
Frequencies -3db ± 5%
Integrated High Mode – 2 sec sliding
Values window Bandpass Measurement Update Rates
Low Mode – 2 sec sliding Valid KPH or 0 to Peak / Peak to Peak
window Simulated KPH values updated every 4 KPH
100ms update rate present periods.
6/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
7/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
Amplitude ±1% of Full Scale Range2 Spectral Lines 6400, 3200, 1600, 800, 400,
200, 100 lines, selectable.
Phase ±3˚ of Input One asynchronous
spectrum per channel.
DC Coupled DC Hz to 50 kHz Windowing provided on
spectrum up to 800 lines,
Amplitude ±1% of Full Scale Range2 Rectangular, Hanning, Flat-
Top, Exponential
Phase ±3˚ of Input
Free Running 1 per channel
Output Up to 4 simultaneous Spectrum
asynchronous waveforms
per channel Zoom 1 asynchronous spectrum
Spectrum per channel.
Synchronous Samples/rev (16, 32, 64, 128,
Sampling Rates 256, 360, 512, 720, 1024, Center Configurable in 1 Hz
2048) Frequency increments
Synch sample rate X rpm ≤
Zoom Factors 2, 5, 10, 20, 50
32 kHz
Spectral Lines 100, 200, 400, 800
Hardware Up to 2048 samples per
Generated waveform, up to 512
2Dynamic Sampling Card
Time Averages
Synchronous i.e. (8 revs @ 256 Amplitude vs. Frequency
Averaging samples/rev), Cumulative Error
(4 revs @ 512 samples/rev)
8/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
9/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
Detection Error detection indicated if Maximum Trigger Input ≤ 1kHz: < 0.5 deg,
change in rotative speed Error with Sine 1kHz – 20 kHz: < 1 deg
between consecutive Wave Input
Keyphasor pulses is
greater than 25%, or shaft
rotative speed is less than
1 rpm, or greater than 120k
rpm
10/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
Time User-programmable,
recurring, scheduled
11/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
Table 1: Event Rate = Shaft rpm x Events/rev Transducer Power Supply Card
Event Rate Rpm Error Phase Error Slot Slots 1 through 5
Positions
1 to 6k +/- < 1 rpm +/- < 1 deg
Voltage -24Vdc (-23.35Vdc to -24.48
6k to 30k +/- 4 rpm +/- < 1 deg Outputs Vdc)
30k to 60k +/- 7 rpm +/- 1 deg Max 84.5 mA ± 4.5 mA
60k to 90k +/- 20 rpm +/- 1 deg Current
90k to 120k +/- 40 rpm +/- 2 deg Short 55 mA ± 5mA per output, 8
Circuit outputs maximum
120k to 300k N/A +/- 3 deg +24Vdc (+24.48Vdc to +23.34
(typ) Vdc)
900k to 1200k N/A +/- 9 deg (+) Bias 3.36 mA ± 0.3mA @ Load: 10 Ω to
(typ) 6.5 kΩ per output, 4 outputs max
12/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
Physical Vibration
Non- 3G @ 5-100Hz
408 DSPi (L x 36.1 x 41 x 10 cm (14.25 x 16 x 3.8 operational
W x H) in)
Shock 10G @ 2mS operational &
Power Supply 18.3 x 13.7 x 9.1 cm (7.2 x 5.4 x non-operational
(L x W x H) 3.6 in)
Environmental Considerations
Weight
The 408 DSPi is designed to meet a broad
408 DSPi 9.5 kg (21 lbs) @ 32 channels range of use cases and environments.
Significant design measures have been
Power Supply 1.3 kg (3 lbs)
implemented to provide a robust electrical and
Construction mechanical package. Shock isolation mounts
are used internally on critical components and
408 DSPi Aluminum Chassis with cast careful attention focused on reliability of the
aluminum front and rear system including extensive shock, vibration,
panels. and temperature exposure. The robust shipping
Black Powder Coating – case is designed for transportation and
textured finish, shipment in the most rigorous environments.
indoor/outdoor use.
Environmentally sealed The 408 DSPi is a measurement “instrument”
momentary tactile switches. and should be treated with the appropriate
Bayonet locking external consideration. Exposure to “extreme”
power connector environments will have constraints. Direct
exposure to condensing liquids, rain, sand, or
Environmental other particulates that could impair ventilation
are however, not appropriate. In scenarios that
Operating 408 DSPi and External may exceed environmental specifications
Temperature PowerSupply custom solutions can be created to meet
0˚ C to +50˚ C (+32˚ F to +122˚ specific needs. If you have any questions
F) regarding an application, please contact your
local Bently Nevada representative.
Rated
specifications at Input Power
fan inlets. Do not
block fans during External Power Supply
operation, un-
obstructed airflow is Input 90/264 Vac, 47/63 Hz auto
required. sensing
13/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
14/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
EMC
EN 61000-6-2
EN 61000-6-4
EN 61000-3-2
EN 61000-3-3
EMC Directive 2014/30/EU
RoHS
RoHS Directive 011/65/EU+2015/863
LV
LV Directive 2014/35/EU
15/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
00 Empty Slot
ADRE 408 DSPi
01 Digital Replay Card w/o Analog
Output Card
168679-AA-BB-CC-DD-EE-FF-GG-HH-II-
JJ-KK 02 Digital Replay Card w/ Analog
Output Card
16/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
00 None
⋮
10 Ten (10) Client Licenses
00 None
17/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
⋮ 100M5072-01
10 Ten (10) CD-ROMs
F: Network Viewer Edition-Media Quantity (For use with ADRE Sxp. 2.8 or later.
(1) (2) Please contact your local sales
representative for additional
00 None ordering information)
00 None
⋮
10 Ten (10) CD-ROMs 2. Sketch the machine.
3. Plug it in.
18/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
The ADRE Quick Configuration software allows
even the novice user to create an Sxp-ready Speed Input/KPH cards (168906–02)
database to configure ADRE and start receiving delivered prior to November 2006
data within minutes. Bently best practices are require an update to work properly
integrated into the drag and drop menu to with the Digital Replay Card.
automatically create data collection
parameters and a suite of plots to ensure the
full power and productivity of the ADRE system
is realized.
The newest to the most experienced ADRE user
can take advantage of the ease, speed, and
expertise of the ADRE Quick Configuration
software so that more time is spent enhancing
productivity utilizing the data, and less time
worrying about manually configuring the
system.
168905-AA
A: Approvals
00 No Approvals
168906-AA
A: Approvals
00 No Approvals
19/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
E: Micro Accelerometers
A: Approvals
00 None
00 No Approvals
F: Triax Accelerometers
KR Korea (safe area)
00 None
B: Output Accessory Option
20/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
Each hammer includes an assortment of tips 169347-01 External Power Supply to 408
and the necessary cable for connection to the DSPi Extension Cable, 1.8 m (6 ft).
408DSPi. Accelerometers can be ordered in sets For use with 169337. Using this
of 4 or 8, and each one will include the cable provides additional cable
necessary cable for connection to the 408 DSPi. length for a total of ~ 3 m (10 ft).
See Figure 4. Convenient for rack mount
Each component of the Impact Hammer Kit applications.
can also be ordered individually if needed, i.e.
169234-01 408 DSPi 19 in Rack Mount Kit
cables, etc. Please refer to the datasheet for the
Impact Hammer Kit for details. 169714-01 Keyphasor input adapter cable
(0.5m). Connects laser
The impact hammers and accels transducer kits to KPH card
require a constant current power 168906 – 02 (or /01). See 408
source. If the end user does not DSPi with Optical KPH and Laser
already have a method to power Tachometer speed input
these devices, a Transducer Power transducers..
Supply Card (168908-AA-BB) will be
required. 166812-01 Laser transducer kit with 2m
cable. Includes transducer and
extension cable. Requires
Additional Accessories adapter cable 169714-01 to
(Accessories are ordered as connect to KPH card 168906 – 02
separate line items) (or /01). See 408 DSPi with
Optical KPH and Laser
Tachometer speed input
172068 Signal Input Cable-SMA to BNC,
transducers.
3 m (10 ft) required for 168905 –
02 (or /01), and 168906 – 02 (or 166813-01 Laser transducer kit with 5m
/01). cable
Includes transducer and
173887 SMA Push-On Adapter, for SMA
extension cable. Requires
to BNC cable 172068. Allows SMA
adapter cable 169714-01 to
cable connector to be pushed
connect to KPH card 168906-02
onto signal input connector for
(or /01). See 408 DSPi with
convenience.
Optical KPH and Laser
286241 BNC male to SMA female Tachometer speed input
Adapter transducers.
21/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
173548-01 ADRE 408 Blank Panel Answer: This would require an additional
Transducer Power Supply 168908-02 and up
172070 Panel screw 4-40 Thread, ¾” to 4 set of 178775-01 and 178897-01 (both
Length connectors are capable of having 4
channels), Transducer connection will be the
Transducer Power Supply Cable Frequently same as Question #3.
Asked Questions 5. What do I need to order if I want to
power 1 to 8 negative bias 3-wire
1. What do I need to order if I want to
transducers (Accelerometers,
power 1 to 4 positive biased
Velomitors, or Proximitor Probe).
Accelerometers/Velomitor (2-wire)
constant current transducers.
22/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
23/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
l 32 GB RAM
l 2.4 Ghz or faster, Xeon
l 512GB PCIe x4 NVMe Storage
l 1.8GHz or faster, Dual Core (notebooks)
l USB 2.0 (or higher)
l 2 GB RAM
l 15.6” LED-backlit FHD + 1920x1080
l 160-250 GB HDD
l External HP DVD/RW Drive Included
l 1000/100 MB Ethernet
l HD webcam
l SXGA 128MB VRAM
l Windows 11 Professional 64-bit OS
ADRE Sxp Notebook Computer l Notebook Carry Case
This computer does not have an
external parallel port. You can also Computer Peripherals
use this computer with ADRE for
Users should evaluate the selection of
Windows software but it is not
additional external peripherals on a case-by-
compatible with the 208DAIU.
case basis. User needs can be very different
and therefore we do not recommend generic
169849 High Performance solutions. We can provide peripherals such as
printers, external hard drives, monitors, or other
Notebook Computer devices that best meet your needs. Please
provide your sales representative with specific
l HP ZBook Fury 16 G9 requirements.
l Core i7 12800HX / 2 GHz
l 32 GB RAM
l USB 4.0
24/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
Data/Database Import
The latest versions (3.1 greater) of the ADRE Sxp
software provide the ability to import vector
and waveform data from a generic delimited
spreadsheet format. Users can select a direct
static type, and asynchronous waveforms.
Imported data can be presented in the ADRE
Sxp software for different types of analysis
and/or presentation needs.
25/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
directly with the 208 DAIU, ADRE for Windows Display Plot / Formats
software can run on the same computer as
ADRE Sxp. Contact your local technical support The following plots can be selected from stored
representative for details specific to your data. Users can configure the display to show
needs. only the applicable plots for any given
application package.
Network and Archive Viewer Edition
Software l Current Values
There are two "Viewer Edition" options for ADRE l Tabular List
Sxp that are specifically designed to meet use
case scenarios that do not require active l Orbit / Timebase (w/ superposition of
control or configuration of a 408 DSPi. All overlay)
versions of ADRE Sxp can read all ADRE for
Windows databases. l Orbit (w/ superposition of overlay)
Network Viewer Edition-The Network Viewer l Timebase (w/ superposition of overlay)
allows a user to "connect to a 408" and view live
data or any archived data on the 408. Users l Continuous Raw Timebase (w/multi
need this if they wish to view live data, decimation)
participate in a live test, etc. The network viewer
can also display all archived data, either l Bode (w/ Forward & Reverse Vector
locally, or on the 408. This option is intended for transforms, coming soon)
applications that require remote participation
in data collection or viewing of live data, as well l Polar (w/ Forward & Reverse Vector
as local viewing of archive data. transforms)
Archive Viewer Edition – The Archive Viewer l Shaft Centerline (Average and
software is intended for situations when a user
requires support from other personnel, typically Instantaneous position & Orbit Overlay)
from a corporate support team or consultant. l X vs. Y
In such cases, support personnel will not
actually be configuring or collecting live data l Trend / Multivariable Trend
from the 408. Once a user has archived and
moved data from the 408, the Archive Viewer l Spectrum / Full Spectrum
provides all viewing features and data
manipulation capability. The Archive Viewer l Waterfall / Full Waterfall (w/ Campbell
allows users to open databases only after they format)
have been archived and moved to another
computer or placed on storage media. The l Cascade / Full Cascade (w/ Campbell
Archive Viewer is not able to connect to a 408 format)
at all.
l Structural Analysis (Timebase
w/Rectangular and Exponential
Windows)
26/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
Connect to 408 √ √
Upload Configurations √ √
to 408
Quick Configuration √ √
Software
Manual Sample √
Control Triggering √
27/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
Training Programs
Training is essential to ensure users are able to
realize full value from their tools in the most
efficient manner. Our technical training group
can provide training to meet your needs.
Training specific to ADRE Sxp and the 408 DSPi
can be provided at your facility or at one of
many Training Centers located around the
world. Contact your local sales representative
for details specific to your needs.
28/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
29/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
Figure 3: 408 DSPi with Optical KPH and Laser Tachometer speed input transducers.
30/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
31/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
32/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
33/34
ADRE Sxp and 408 DSPi
Datasheet 172179 Rev. AN
Bently Nevada, ADRE, Keyphasor, M2, Proximitor, System 1, Velomitor and Orbit Logo are registered trademarks of
Bently Nevada, a Baker Hughes business, in the United States and other countries. The Baker Hughes logo is a
trademark of Baker Hughes Company. All other product and company names are trademarks of their respective
holders. Use of the trademarks does not imply any affiliation with or endorsement by the respective holders.
Baker Hughes provides this information on an “as is” basis for general information purposes. Baker Hughes does not
make any representation as to the accuracy or completeness of the information and makes no warranties of any
kind, specific, implied or oral, to the fullest extent permissible by law, including those of merchantability and fitness
for a particular purpose or use. Baker Hughes hereby disclaims any and all liability for any direct, indirect,
consequential or special damages, claims for lost profits, or third party claims arising from the use of the
information, whether a claim is asserted in contract, tort, or otherwise. Baker Hughes reserves the right to make
changes in specifications and features shown herein, or discontinue the product described at any time without
notice or obligation. Contact your Baker Hughes representative for the most current information.
The information contained in this document is the property of Baker Hughes and its affiliates; and is subject to
change without prior notice. It is being supplied as a service to our customers and may not be altered or its content
repackaged without the express written consent of Baker Hughes. This product or associated products may be
covered by one or more patents. See Bently.com/legal.
34/34