0% found this document useful (0 votes)
2 views

S-1

The document contains detailed architectural and structural plans for a proposed bungalow residence, including foundation, roof beam framing, and lower and upper roof framing plans. It specifies materials, dimensions, and construction notes, emphasizing compliance with building codes and the importance of obtaining approvals for any changes. Additionally, it outlines ownership rights regarding the plans and specifications, prohibiting unauthorized duplication.

Uploaded by

lagmanadrian13
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2 views

S-1

The document contains detailed architectural and structural plans for a proposed bungalow residence, including foundation, roof beam framing, and lower and upper roof framing plans. It specifies materials, dimensions, and construction notes, emphasizing compliance with building codes and the importance of obtaining approvals for any changes. Additionally, it outlines ownership rights regarding the plans and specifications, prohibiting unauthorized duplication.

Uploaded by

lagmanadrian13
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

A B C A B C A B C A B C

6.50 6.50 6.50 6.50


2.10 2.90 1.50 2.10 2.90 1.50 2.10 2.90 1.50 2.10 2.90 1.50

4" THK. CONC. SLAB WITH STAINLESS STEEL


S 26° 46' E 6.50m 10mmØ DEF. BAR S 26° 46' E 6.50m S 26° 46' E 6.50m S 26° 46' E 6.50m ROOF GUTTER
1.50
03 04 SPACED @ 0.40m O.C. B.W. 03 04 03 04 03 04

1.50

1.50

1.50
C1F1 C1F1 C1F1
FTB
1 FTB
1 RB RB
1 1
2"X4"X1.5mm
C-PURLINS SPACED

2.55
@0.60M O.C.
3.00
3.00

3.00

3.00

3.00
FTB

FTB

FTB

RB

RB

RB
WF

4.60

4.60

4.60

4.60
C1F1

2"X4"X3mm RAFTER TRUSS

2"X4"X3mm RAFTER TRUSS

2"X4"X3mm RAFTER TRUSS


FTB
2 2 RB RB
2 2

2.05
C1F1 WF C1F1
5" THK. CHB FIREWALL 5" THK. CHB FIREWALL 5" THK. CHB FIREWALL 5" THK. CHB FIREWALL 5" THK. CHB FIREWALL 5" THK. CHB FIREWALL

S 63° 14' W 15m

S 63° 14' W 15m

S 63° 14' W 15m

S 63° 14' W 15m


N 63° 14' E 15m

N 63° 14' E 15m

N 63° 14' E 15m

N 63° 14' E 15m


WF WF

1.35
5.40

5.40

5.40

5.40
15.00

15.00

15.00

15.00
RB

RB

RB
12mmØ ROUNDBAR SAGROD

3.80

3.80

3.80

3.80
FTB

FTB

FTB
WF

2.45
8.40

8.40

8.40

8.40
C1F1 C1F1 C1F1 2"X4"X1.5mm

2"X4"X3mm RAFTER TRUSS

2"X4"X3mm RAFTER TRUSS

2"X4"X3mm RAFTER TRUSS


C-PURLINS SPACED
3 FTB FTB
3 RB RB
3 @0.60M O.C. 3
FTB

FTB

FTB
3.00

3.00

3.00

3.00
RB

RB

RB
C1F1 C1F1 C1F1
5.10

5.10

5.10

5.10
4 FTB FTB
4 RB RB
4 4
0.80 1.30

0.80 1.30

0.80 1.30

0.80 1.30
2.10

2.10

2.10

2.10
02 01 02 01 02 01 02 01
N 26° 46' W 6.50m N 26° 46' W 6.50m N 26° 46' W 6.50m N 26° 46' W 6.50m
STAINLESS STEEL
3.30 3.20 3.30 3.20 3.30 3.20 ROOF GUTTER 3.30 3.20
6.50 6.50 6.50 6.50

1 FOUNDATION PLAN 1 ROOF BEAM FRAMING PLAN 1 LOWER ROOF FRAMING PLAN 1 UPPER ROOF FRAMING PLAN
S-1 SCALE: 1:100 MTS S-1 SCALE: 1:100 MTS S-1 SCALE: 1:100 MTS S-1 SCALE: 1:100 MTS

16mm THK. x 10"X6" MS PLATE


16mmØ x 40cm ANCHOR BOLT C/W ACCESSORIES
6-12mmØ DEF. BARS W/ 10mmØ 0.30
STIRRUPS SPACED @2-0.05; 4-0.10; 1.00
2-0.15; REST @0.20m O.C. F.F.L. GROUND LEVEL

0.50
0.30
LENGTH (VARIES)

6-16mmØ VERTICAL BARS


0.20 WITH 10mmØ TIES
1@50, REST @150mm O.C.

1.20
0.30

0.20
1.00

6-16mmØ REINF. BARS


SECTION O.C. BOTHWAYS GENERAL NOTES
1. DO NOT SCALE DRAWINGS. FIGURED
DIMENSIONS ARE TO TAKE PRECEDENCE.
2. THESE DRAWINGS ARE TO BE READ IN
CONJUNCTION WITH ALL RELEVANT ENGINEERS AND
CONSULTANTS COMPUTATIONS. FOR ANY

0.30
1 TIE BEAM DETAIL (FTB) 6-16mmØ REINF. BARS
O.C. BOTHWAYS
DISCREPANCY BETWEEN ARCHITECT URAL AND
ENGINEERING PLANS PLEASE CLARIFY WITH THE
ARCHITECT BEFORE PROCEEDING.
3. FOR ANY PROCEDURE THAT THE GENERAL
S-1 SCALE: 1:20 MTS PLAN CONTRACTOR MAY WANT TO CHANGE OR ADO FROM
THE PLANS OR SPECIFICATION PROVIDED BY THE
ARCHITECT PLEASE NOTIFY AND WAIT FOR APPROVAL
1.00 FROM THE PROJECT ARCHITECT.
4. PLEASE INFORM THE ARCHITECT WHEN IN
DOUBT, SOME DETAILS, SPECIFICATION, DIMENSIONS
ETC. CAN BE VULNERABLE TO HUMAN ERRORS AND
ELEVATION/SECTION SHOULD BE DISCUSS DURING MEETING OR VIA PHONE
OR EMAILS BEFORE PROCEEDINGS.
5. PL E AS E PR O V ID E S HO P D R AW I NG S AN D

C1-F1 SPECIFICATION FOR EVERY NEW INSTALLATION


PROCEDURE NOT SPECIFIED FROM THE CONTRACT
DOCUMENTS AND TO BE APPROVED BY THE PROJECT

1 COLUMN AND FOOTING DETAILS ARCHITECT BEFORE PROCEEDING.


6. FOR ANY NEW MATERIALS NOT SPECIFIED IN
THE CONTRACT DOCUMENTS THE GENERAL

S-1 SCALE: 1:20 MTS


CONTRACTOR SHALL PROVIDE SHOP DRAWINGS,
SAMPLE AND SPECIFICATIONS ACQUIRED FROM THEIR
SUPPLIER, AND FOR SOME INSTANCES PRODUCT
D E M O S H A L L B E R E Q U I R E D .
7. ALL WORKS MUST COMPLY WITH THE NATIONAL
BUILDING CODE OF THE PHILIPPINES AND ALL OTHER
RELEVANT BY-LAWS AND AUTHORITIES.

Republic Act No. 9266 SECTION 33.


STRUCTURAL ENGINEER: OWNER: PROJECT TITLE: SHEET CONTENT: SHEET NO:
Ownership of Plans, Specifications and other Contract Documents. - Drawings and
specifications and other contract documents duly signed, stamped or sealed, as FOUNDATION PLAN DESIGNED BY:
XXXXXXXXXXXXXXXXXXXXXXX
MS. ANDREA C. ANTONIO PROPOSED BUNGALOW RESIDENCE
instruments of service, are the intellectual property and documents of the architect,
whether the object for which they are made is executed or not. It shall be unlawful for
any person to duplicate or to make copies of said documents for use in the repetition
ROOF BEAM FRAMING PLAN
ROOF FRAMING PLAN DRAWN BY: CJIMENEZ
S-1 6 of 7
PRC NO. XXXXXXX VALIDITY: XXXXXXX TYPICAL DETAILS
of and for other projects or buildings, whether executed partly or in whole, without the
PTR NO. XXXXXXX DATE: XXXXXXX DATE: MAY 2025
written consent of architect or author of said documents. STRUCTURAL
TIN NO.: XXXXXXX PLACE: XXXXXXX

You might also like