HZDR Publications 13196
HZDR Publications 13196
Hoang, D. H.; Heitkam, S.; Kupka, N.; Hassanzadeh, A.; Peuker, U. A.; Rudolph, M.;
Originally published:
December 2018
DOI: https://doi.org/10.1016/j.cherd.2018.11.036
https://www.hzdr.de/publications/Publ-28514
CC BY-NC-ND
Froth properties and entrainment in lab-scale flotation: A case of
carbonaceous sedimentary phosphate ore
Duong Huu Hoang1, 2, 3, *, Sascha Heitkam4, Nathalie Kupka1, Ahmad Hassanzadeh1, Urs A. Peuker2, Martin Rudolph1
1
Department of Processing, Helmholtz Institute Freiberg for Resource Technology, Helmholtz-Zentrum
Dresden-Rossendorf, Chemnitzer Straße 40, Freiberg, Germany
2
T
Institute of Mechanical Process Engineering and Mineral Processing, Technische Universität Bergakademie
Freiberg, Agricolastraße 1, Freiberg, Germany
IP
3
Department of Mineral Processing, Faculty of Mining, Hanoi University of Mining and Geology, Duc Thang,
Bac Tu Liem, Hanoi, Vietnam
R
4
Department of Transport Processes at Interfaces, Institute of Fluid Dynamics, Helmholtz-Zentrum Dresden-
Rossendorf, Bautzner Landstraße 400, 01328 Dresden, Germany
SC
*Corresponding author: [email protected] / [email protected] U Tel: +49 351 260 4482
N
A
M
Graphical abstract: Flotation cell schematically represented as interacting pulp and froth
zones in derivation of overall recovery and measuring the froth structure using DFA
ED
E PT
CC
A
1
Highlights
T
modeling
IP
The analyses offer novel support for the understanding of entrainment
R
phenomena
SC
Abstract
U
In flotation, the froth characteristics strongly influence the separation process as they are
N
linked to water recovery, bubble size, entrainment of gangue particles, flotation rate
constants and finally grade and recovery. In the case of a high-grade apatite ore with a
A
high mass pull in lab-scale flotation, significant changes in pulp and froth properties
occur, such that the froth stability decreases with increasing flotation time. These
M
changes can be related to different particle and reagent concentrations. We describe the
change of entrainment in a rich apatite ore batch flotation with time more precisely by
measuring froth properties using a Dynamic Froth Analyzer (DFA). It is concluded that the
ED
degree of entrainment is not only dependent on particle size but also the pulp density
due to its effect on particle settling and also froth properties in varying resistance to
drainage. Through a combination of time-resolved dynamic froth analysis and automated
mineralogy, we identify the dynamic effects governing in the froth and compare the
PT
entrainment results with existing models. Furthermore, our analyses offer novel support
for the extension of the common understanding of the entrainment phenomena.
E
CC
1. Introduction
Froth flotation belongs to the group of heterocoagulation separation techniques. It is
classically divided into two active zones, the pulp zone, where particle collection occurs
2
and the froth zone, where the froth recovery of particles is governed by true flotation,
drop back and entrainment.
In froth flotation, the collision probability in the collection zone is governed by the
hydrodynamics of particle-bubble interactions (Wills and Finch, 2016). The true flotation
event occurs when hydrophobic mineral particles collide with bubbles, attach in the
liquid-gas interface and form stable particle-bubble aggregates lifted upwards against
gravity towards the froth zone (Yianatos et al., 2009).
There are mechanical transportation processes of hydrophilic gangue minerals occurring
within the froth phase including entrapment, entrainment, and recovery by composite
particles and slime coatings. Unlike true flotation, entrainment is not chemically selective
T
and is a mechanical mass transfer process by which particles suspended in the water
between bubbles enter the flotation froth from the top pulp region and are transferred
IP
through the froth layer into the concentrate (Wang et al., 2015).
This study focusses on the characterization of the froth phase especially on the change of
R
froth properties during lab-scale flotation of rich carbonaceous apatite ore. In addition,
SC
the entrainment modelling is discussed in detail and common models are applied to
predict the degree of entrainment.
bubbles from gangue minerals in the slurry. It leads to transporting the precious materials
from the bulk slurry to the concentrate launder (Heath, 2013). Although the importance
of froth is widely acknowledged, there is considerable lack of studies concerning the
ED
the bubble film as the solid particles are trapped within the Plateau border and ensuring
increased roughness of the lamellae respectively (Marozva, 2015). In metal foam
production particles inside the lamellas are even at the origin of the foam stability
E
(Banhart, 2006).
CC
Froth ability and stability: There is no standard coefficient of frothing; froths are
characterized by their froth ability and their froth stability. The froth ability referred to as
froth capacity, which is the quantitative assessment of the froth height or volume. This is
usually measured at steady-state conditions. The static froth stability often relates to the
A
lifetime of the froth (after the generation or bubbling step has been completed)
(Farrokhpay, 2011; Pugh, 2016). Froth stability mainly depends on the typically non-ionic
amphiphilic frothers (type and concentration) as well as the suspended particles, in
particular with respect to particle hydrophobicity and size (Schwarz and Grano, 2005)
In flotation, the froth needs to be dynamically stable whilst bubbling is occurring, i.e.
stable against bubble coalescence in the froth. However, it should be unstable without
3
bubbling further, i.e. in the launder, in order to results in a froth depleted suspension
which can be further handled by pumping or filtration.
Froth structure: The froth structures elaborated on the pulp surfaces in froth flotation
cells can provide useful information with respect to both grade and recovery of valuable
minerals. Generally, digital image processing techniques are used for froth structure
characterization in industrial flotation cells (Moolman et al., 1995).
Measurements of froth ability and stability:
There are several techniques which have been published in the literature to analyze froth
properties such as X-ray microtomography (XµT) (Richardson et al., 2005; Stock, 1999,
2008), Dynamic Neutron Radiography (dNR) (Heitkam et al., 2018) and Magnetic
T
resonance imaging (MRI) (Blümich, 1995, 2000; Laity et al., 2010; Richardson et al., 2005).
IP
In this study, a Dynamic Froth Analyser (DFA) is used for evaluation of the froth
ability/stability. Froth height and lifetime of a bubble are quantitative parameters
R
representing the dynamic stability. In the DFA technique, the froth rises within a column
and the height is measured as a function of time. The maximum froth height is defined as
SC
the froth reaches a horizontal asymptote, i.e. gas release rate of bursting bubble at the
top of the froth is equal to the flow rate of gas into the suspension. The maximum height
can be well correlated with the ability and stability of the froth (Pugh, 1996; Schwarz,
2004).
U
Several indicators have been introduced for assessment of the froth stability including
N
froth half-life time, froth maximum height at equilibrium, bubble growth across the froth
phase, air recovery and solid loading on bubbles on the top of the froth surface, froth
A
velocity, and froth rise velocity (Farrokhpay, 2011). Bikerman (1973) determined the
M
dynamic stability factor (∑) as the ratio of the maximum volume of generated foam or
froth to the gas flowrate given by Eq. 1. This factor has been used in froth flotation
studies, e.g. Mackay et al. (2018), McFadzean et al. (2016a) and McFadzean et al. (2016b).
ED
There the effects of particle size on dynamic froth stability have been studied showing the
link between dynamic froth stability and flotation performance.
𝑉𝑓 𝐻max 𝐴
∑= = (Eq. 1)
𝑄 𝑄
PT
where Vf is the froth volume, Q is the gas flowrate, Hmax is the maximum equilibrium
height and A is the cross-sectional area of the column.
E
The ratio physically translates to the average lifetime of bubbles in the froth. In addition
to the maximum equilibrium height as a measure of froth stability, the froth rate has
CC
been applied (Marozva, 2015). Barbian et al. (2003) used the froth growth exponential
model as a function of froth height and time:
𝐻𝑓 = 𝐻max (1 − 𝑒 −𝑡⁄𝜏 ) (Eq. 2)
A
where Hmax and τ are the maximum equilibrium height and the average lifetime of
bubbles in the froth phase, respectively.
T
ENTi =
(mass of free gangue particles per unit mass of water)tailings
IP
In the pulp phase, a classification function i.e. CFi is proposed to describe the state of
solids suspension (Wang et al., 2015; Zheng et al., 2006), while in the froth phase the
R
degree of entrainment (ENTi) is proposed to describe the classification effect of the
drainage of entrained particles (Bisshop, 1974; Kirjavainen, 1992; Savassi et al., 1998).
SC
There are numerous, mostly empirical models aimed at describing mechanical
entrainment of gangue particles into the concentrate. In this study, two common models
of entrainment used in industry including Savassi and Yianatos models are applied to the
experimental data of lab scale flotation test work.
U
N
The empirical partition curve proposed by Savassi et al. (1998) can be shown in Equation
3:
A
2
ENT𝑖 = 𝑑𝑝,𝑖 adj 𝑑𝑝,𝑖 adj
(Eq. 3)
M
exp[2.292( ) ]+exp[−2.292( ) ]
𝜉 𝜉
ln(1⁄𝛿 )
adj = 1 − exp(𝑑 (Eq. 4)
𝑝,𝑖 ⁄𝜉 )
ED
where 𝜉 is the entrainment parameter defined as the particle size for which the degree of
entrainment ENTi equals 0.2, δ is the drainage parameter which is related to the degree
of preferential entrainment of coarse particles. The entrainment parameter 𝜉 is
PT
calculated based on the froth residence time of air which is given by: λ𝑎𝑖𝑟 = ℎ𝐹 ⁄𝐽𝑔 ,
where Jg is the superficial gas velocity (𝐽𝑔 = 𝑉𝑔 ⁄𝐴𝑐𝑒𝑙𝑙 ), hF is the froth depth. The fitted
values for the entrainment parameter ξ and the drainage parameter δ using the equation:
E
Yianatos and Contreras (2010) proposed a particle entrainment model for industrial
flotation cells using an entrainment factor EFi as:
𝜑
𝑅𝑔,𝑖 𝑑
EF𝑖 = = exp [−0.693 (𝑑 𝑝,𝑖 ) ] (Eq. 5)
A
𝑅𝑊 𝑝,0.5
where Rg,i is the gangue recovery of size class i, RW is the water recovery, dp,i is the mean
particle size of class i, dp,0.5 corresponds to the mean particle size at EFi = 0.5 for each data
set (similar to d50 or cut size) ɸ is a drainage parameter depending on the mineral
characteristics and cell operating conditions, that may be obtained by a least squares
numerical method.
5
2. Material and methods
Ore: The carbonaceous sedimentary apatite ore used contains 64 % apatite, 27 %
carbonates, 8 % various silicates (i.e. quartz, almandine, zircon, titanite, muscovite,
sandine, albite, orthoclase, plagioclase and phlogopite) and 1 % other minerals. The ore is
ground dry using a ball mill to reach a d80 of 50 µm. Figure 1 exhibits a schematic view of
the preparation of the samples, conditioning and conducting the flotation experiments.
Froth flotation procedure and sample preparation for dynamic froth analysis with DFA-
100: The batch flotation tests were performed using a mechanical cell built at the TU
Bergakademie Freiberg, Germany. The detailed flotation procedures are described
T
elsewhere (Hoang et al., 2018a; Hoang et al., 2017, 2018b). The flotation tests in this
study were conducted with the impeller tip speed of 2.5 m/s using the double finger
IP
impeller type at an air flow rate of 2 l/min and solids content 8 vol. %, the reagents
regime is shown in Figure 1.
R
The pulp in the flotation cell at the given flotation times (remaining pulp suspension) is
collected right after the flotation tests. A 60 ml sample of this pulp is transferred to a
SC
transparent glass column of 40 mm inner diameter of the Dynamic Froth Analyzer DFA-
100 (Krüss, Germany). As reported in Geldenhuys and McFadzean (2018) the diameter
does have an effect on the dynamic froth stability, but since it is constant for all tested
U
suspensions the results should be comparable amongst one another. Subsequently, the
froth is generated by bubbling the air through a ceramic frit (pore diameter 16 µm –
N
45 µm) at 0.5 l/min air flow rate (standard conditions) for a constant duration of 100 s.
The froth properties including its height and structure are recorded to evaluate dynamic
A
parameters of the froth ability, froth stability and time-dependent bubble size
distribution. The bubble size distribution is observed as well at different camera positions,
M
i.e. froth heights, employing an adapted image processing algorithm described in section
3.3 below. The liquid content is derived from the electric conductivity, measured at up to
seven height increments of the froth. Details of the measurement principle are given by
ED
used as a frother, provided by Sigma-Aldrich, Germany. The collector was Berol 2015,
which is a formulation of an amphoteric collector and a non-ionic secondary collector
supplied by AkzoNobel Surface Chemistry, Sweden.
A
Mineral Liberation Analysis: A detailed description of the sample preparation process for
automated mineralogy with the Mineral Liberation Analyzer (MLA) can be found in
previous studies Hoang et al. (2017, 2018b), Leißner et al. (2016a) and Leißner et al.
(2016b). Twenty-four samples of all size-by-size sub-samples for the feed, concentrates
and tailings are analysed with this automated mineralogical technique. The effect of
particle size of hydrophilic minerals on the degree of entrainment is assessed at different
flotation times. The ENTi is calculated using the recovery of fully liberated assumingly
hydrophilic silicates (100% of the free surface in each particle cross-section). Depending
6
on the particle size, between 303,000 to 670,000 liberated silicate particles in each size
fraction obtained by MLA were included in the calculations for a sound statistical
treatment of the individual particle information.
T
before.
IP
3.1. Surface activity
R
The supernatants of the concentrates and pulps are characterized for their dynamic
surface tension, i.e. surface tension at various ages of the surface after being created,
SC
using a bubble pressure tensiometer BP-100 (Krüss, Germany). Figure 3 demonstrates the
dynamic surface tension term versus the surface age and its change as a function of the
flotation time. It can be evidently seen that a decrease in surfactant concentrations with
U
flotation time leads to an increase in the surface tension of the remaining pulp. The non-
ionic frothers as well as the non-surface-bound amphoteric collectors appear to be highly
N
surface active reducing the surface tension of the supernatants to less than 50 mN/m
(Figure 2a). It is also significantly noticeable that the surface activity of the supernatants
A
of the concentrates is substantially greater than those of the pulp (Figure 2b). Indeed, this
emphasizes the enrichment of surface active frothers and free collectors in the
M
concentrates, hence the term “frothing out”. There is a faster adsorption of the surface
active molecules into the liquid-gas interface of the supernatants of the concentrates
(visible in the dashed curves in Figure 2a) as compared to the curves for the pulp
ED
supernatants. This could be due to a preferential enrichment of the small MIBC molecules
which should have a higher diffusivity and a faster kinetics of adsorption as compared to
the larger amphoteric collectors.
PT
the froth stability is more dependent on the viscoelasticity and repulsive interactions
CC
within thin film lamellae (Pugh, 2016). It is observed that as the flotation time increases
(from P0 to P4) the froth height decreases (Figure 3a). It is attributed to the decrease in
frothing reagent concentrations in the pulp due to the high mass pull. These results
indicate that in the case of lab-scale flotation of rich apatite ore, froth ability and froth
A
The temporal froth height development before reaching the maximum can be fitted with
an exponential function (Barbian et al., 2005; 2003) as shown in Figure 3b. The regression
analysis gives values of the parameters τ and Hmax corresponding to the characteristic
average bubble lifetime and maximum height, respectively, which can be used as proxies
7
for froth stability. The rate of decreasing froth height after stopping of bubbling (at 100 s)
is corresponding to the bubble burst rate.
The average lifetime of bubbles and the dynamic stability factor were both at 0.29 min
before flotation. After 6 min flotation time, these values reduced to 0.03 min and
0.04 min, respectively.
As demonstrated in Figure 5a, the liquid content decreases from the base to the top of
the froth through drainage. This is in line with the prediction by the foam drainage
equation (Weaire et al., 1997). In order to reach a steady state, further down in the froth
the cumulative water flow from above has to pass, which requires a higher drainage
permeability and thus, higher liquid fraction. Additionally, coarsening takes place (see
T
section 3.3 below) which results in larger bubbles in the upper part of the froth, yielding
higher drainage permeability at a given liquid fraction and consequently, smaller liquid
IP
content.
In addition, Figure 5b, c, and d show the liquid content (degree of wetness) decreasing
R
with increasing the flotation time at various fixed froth heights. This effect of reduced
SC
liquid content with flotation time is due to the significant reduction in both surfactant and
particle concentrations. Firstly, the particle content directly hinders drainage along the
plateau borders and thus, lower particle concentration results in higher drainage rate and
consequently, less liquid content. Secondly, a lower surfactant concentration results in
U
stronger coarsening of the froth (see section 3.3 below) and larger bubbles result in
N
higher drainage permeability for a given liquid fraction (Cantat et al., 2013).
Consequently, the foam dries faster.
A
3.3. Bubble size distribution
M
The bubble size is assessed by grey scale images from the plan-parallel side of the column.
Due to total reflection, the thin lamellas between bubbles and wall appear bright while
ED
plateau borders appear dark. The particles suspended inside the lamellas withhold a bit of
water around them, appearing also black and disturbing image processing. As seen in
Figure 7, the bubble sizes in the froth phase are significantly increased with increasing
PT
flotation time. They become larger due to a reduction of the reagent concentrations and
a decrease in the solids content in the pulp.
E
The images are treated similarly to the method proposed by Boos et al. (2013). Firstly,
CC
touching Plateau borders and reveals the contact lines of the lamellas at the wall
separating the bubbles. Each area bound by a set of contact lines represents the contact
area of one bubble with the wall. Segmentation (Figure 7d) yields the size of all contact
areas in the field of view. Objects close to the rim of the image or with an area smaller
than 10 px2 are ignored. The blue circles in Figure 7d mark all accepted bubble contact
areas.
8
In this study, the bubble size is represented by the equivalent spherical radius r of the
bubble volume and the contact area size is denoted by its equivalent circular radius rs.
Using the Surface Evolver, Wang and Neethling (2009) found the statistics for the relation
of r and rs:
𝑟𝑠 3.51(𝑟𝑠 ⁄𝑟)4.61
𝑓( ) =
𝑟 1 + 𝑒𝑥𝑝(47.96(𝑟𝑠 ⁄𝑟 − 1.08))
Employing the reconstruction algorithm of Wang and Neethling (2009), the corresponding
distribution of the volume equivalent bubble radius r of the wall-touching bubbles is
T
reconstructed. Taking into account all bubbles from all images for a certain flotation time
IP
and a certain foam height reveals the bubble size distributions presented in Figure 8a.
From these distributions, the Sauter mean radius r32 is derived, presented in Figure 8b.
R
In Figure 8 it can be clearly seen that bubbles increase in size with froth height in the
SC
column. In general, two mechanisms for foam coarsening exist, i.e. gas diffusion and
lamella rupture. Since the liquid content of the froth is high and the bubbles are relatively
U
large, gas diffusion acts in the order of tens of minutes (Cantat et al., 2013) and hence,
can be neglected. Consequently, the coarsening must be dominated by film rupture,
N
which could result from the low concentration of surfactants as well as from the presence
A
of hydrophobic particles suspended in the lamellas (Pugh, 1996).
M
This finding is in line with the reduced bubble lifetime in section 3.2. Reduction of the
foam height and coarsening both results from lamella rupture.
ED
In the literature, several models for the bubble size evolution in coarsening froth are
developed (Park, 2015). However, employing these models requires well defined particle
sizes, contact angles and concentration, which is not applicable to realistic ore samples
PT
such as in the present experiment. Developing a suitable froth coarsening model for
realistic ore samples is beyond the scope of this paper, especially since the variations of
E
The fully liberated silicate minerals identified in automated mineralogy are assumed as
hydrophilic and they do not contain Ca2+ and Mg2+ ions which might lead to true flotation
by surface activation. Consequently, these particles are recovered into the concentrate by
entrainment only. Thus they are used as “natural tracer particles” to study entrainment
effects.
9
3.4.1. Water recovery versus silicates recovery
Entrainment is strongly dependent on the water, which is the carrying medium to transfer
the entrained mineral particles into the concentrate in flotation processes. In general, the
correlation between the recovery by entrainment and the water recovery shows a linear
trend for fine particles and a parabolic trend for coarse particles (Figure 9), which agrees
with observations in (Wang et al., 2015; Zheng et al., 2006). Fine silicate particles are
recovered by entrainment at a rate similar to the amount of water recovered while
coarser hydrophilic particles drain more quickly from the froth to the pulp, i.e. against the
upward movement of bubbles, and therefore are entrained into the concentrate at a
lower rate than finer particles.
T
As expected, Figure 9 shows a clear correlation between the amount of cumulative water
IP
and fully liberated silicate particles recoveries. From these results, it can be concluded
that it is important to control the froth zone to achieve a lower ratio between the water
and mass recovery, i.e. a drier froth. This will lead to an increased grade of the
R
concentrates.
SC
3.4.2. Degree of entrainment
In the lab-scale flotation cell, the silicates concentration in the pulp decreases with
U
flotation time as solid particles and water are continually removed during flotation, and
additional water is added to maintain a constant pulp-level. In this study, the degree of
N
entrainment for different flotation times is calculated based on the cumulative recovery
A
of fully liberated silicates and the tailings concentration is that in the cell at the
completion of the test.
M
Figure 10 shows the change of ENTi and the average size of the manually sieved fractions
of the fully liberated silicate particles as a function of flotation time (affecting pulp
rheology and froth properties), which is only possible through automated mineralogical
ED
analysis. As can be seen in Figure 10, the mean size of liberated silicates particles is
smaller than the manually sieved fractions.
For the finest fraction (0-20 µm), the ENTi is slightly increasing with increasing flotation
PT
time. The average particle size in this fine fraction is almost constant with respect to the
flotation time due to the low inertia of the particles and thus no settling related
enrichment. In the pulp phase, fine particles are easily suspended in the water or the
E
water film surrounding the bubbles in the region below the pulp/froth interface as
compared to coarser particles and hence they have a higher chance to travel up through
CC
this lab-scale batch flotation of high-grade apatite ore leading to severe changes of pulp
properties (particularly the pulp density), change in particle size and also froth properties
(Hoang et al., 2017). The decrease of the pulp density and the froth stability with flotation
time leads to an increase of the settling velocities and more likely drop back (drainage) to
the pulp for coarser particles. This is an effect that has not been observed and mentioned
before, to the best of our knowledge.
10
3.5. Modelling of entrainment
Figure 11 displays a reasonable agreement between the obtained experimental data at
different flotation times and predicted results of both empirical models used. The model
of Savassi (Savassi et al., 1998) fits well to intermediate sizes. The deviation for ultrafine
particles may be caused by neglectance of mechanisms such as entrapment in the froth
phase (Zheng et al., 2006). Yianatos’ model shows a good fit for fine and coarse particles.
However, in this study, the range of particle sizes is quite narrow and rather fine for all
fractions studied (fine flotation at d80 of 50 µm). The ENTi can be also described as a
power function of the mean particle size with high R-squared. It can be found that the
best fit function depends on the flotation time (pulp and froth properties), this might be
T
influenced by other mechanisms such as entrapment in addition to entrainment in the
water (Zheng et al., 2006). The models do not consider other important factors, i.e. cell
IP
operating conditions, pulp density, and drainage parameter.
R
The fitted values in Yianatos’ model of the drainage parameter ɸ for different flotation
times are shown in Figure 12a. An increase in the flotation time (decrease in pulp density)
SC
results in a decrease in its degree of entrainment that changes the drainage parameter in
the model. Hence, in the lab-scale batch flotation of high-grade ores, the drainage
U
parameters significantly dependent on flotation time due to a strong reduction of pulp
density. This result must be taken into consideration for the development of entrainment
N
models in batch conditions. In this regard, a number of studies also reported that there
A
was an increase in the recovery of non-floatable gangue by increasing pulp density while
water recovery was constant (Cilek, 2009; Warren, 1985) which is in good agreement with
M
the presented outcomes. However, none of these studies proposed the simultaneous
effect of pulp density and flotation time on the entrainment phenomenon.
ED
As mentioned above and shown in Figure 11, the ENT can be also described as a power
function of the mean particle size:
PT
𝐸𝑁𝑇 = 𝐴 ∗ 𝑑𝑝 𝐵 (Eq. 6)
where A and B are constants which depend on the ore characteristics, froth properties,
E
the cell design and operating conditions, and especially in this case the pulp density. The
CC
data shows a good correlation between values A and B over flotation time and pulp
densities (cf. Figure 12a).
A
3.6. The effect of pulp density and particle settling velocity on the
entrainment
As mentioned earlier, the change of pulp density is significant in this study due to a high
mass pull. Differences in the ENTi with different size and pulp densities are likely to be a
consequence of differences in settling rate within the pulp, at the interface or froth phase
where flow can be considered in the Stokes regime (Wang, 2017). Under these
11
conditions, the particle settling rate of entrained particles in the fluid can be
approximated using Stokes’ law (Smith and Warren, 1989).
The amount of water flowing upward and downward is changing by variation of the
flotation time and the froth height. There is a great variation in liquid holdup from the
T
pulp/froth interface to the froth surface, liquid velocity varies with position due to a
IP
change in water content in the froth (Neethling and Cilliers, 2009). Liquid holdup
decreases with height in the froth due to drainage. An increase in the liquid velocity as it
R
rises within the froth and therefore the drag force increases upon the particles.
SC
(Neethling and Cilliers, 2002a, b) proposed that the motion of the entrained materials in
the froth is a consequence of a balance between liquid motion, particle settling and
U
particle dispersion. The amount of material entrained to the concentrate is determined
by the net flow of water including suspended solid particles upwards (Wang, 2017). There
N
are three distinct regions within the froth zone. Region 1 is just above the pulp/froth
A
interface where there is a rapid decrease in gangue solid concentration due to rapid
decrease in water content. Region 2 is in the center of the froth layer, where the balance
M
of the liquid motion and the hindered solid settling determines the relative motion of the
gangue particles, resulting in a steady reduction in the concentration of gangue particles
ED
as the height from the pulp/froth interface increases. In the upper region 3, the gangue
particle concentration remains relatively constant, due to there being no relative
downward motion of the solids with respect to the water in this region.
PT
The motion of solid particles at the interface may depend on the settling and drag forces
acting upon the particles. According to the Bubble Swarm Theory, the interface region is
E
where water and suspended solid particles are being pushed upwards by rising air
CC
Steinour (1944) studied the sedimentation of small uniform particles, using the viscosity
A
of the fluid, the density of the suspension and a function of the voidage of the suspension
to take account of the character of the flow spaces. The apparent settling velocity of
particles within the froth undergoing hindered settling under laminar conditions can be
estimated from the following (Ray, 1993; Richardson and Zaki, 1997):
(𝜌𝑠 −𝜌𝑓 )gd𝑖2
𝑣settling,𝑖 = 𝑒 2 10 −1.82(1−𝑒) (Eq. 7)
18𝜇𝑖
12
where, s and f are the densities of silicates particle (2,650 kg/m3) and water (1,000
kg/m3), respectively and g is the gravitational acceleration (9.81 m/s2), is the voidage of
suspension, µi is the viscosity of pulp; it can be calculated approximately from the volume
fraction and the viscosity of the liquid using Einstein’s equation:
μi = μw (1 + 2.5φpulp,i ) (Eq. 8)
where µw is the dynamic viscosity of water (1.002 mPa·s) and ɸpulp,i is volume fraction at
flotation time i.
T
Figure 12c shows the degree of entrainment plotted against vsettling and mean fully
IP
liberated silicates size of different fractions at different flotation times. As can be seen,
the degree of entrainment is correlating with vsettling over flotation time, suggesting that
R
the particle settling rate is the key factor (Wang, 2017).
SC
A power relationship was observed between the ENT and a function related to the
particle settling rate and pulp viscosity (Figure 12c). The particle settling velocity increases
U
with the increasing particle size due to an increase in the apparent immersed weight of
the coarser particles.
N
4. Conclusions
A
We investigated the froth properties (froth ability, stability, and its structure) in a lab-
M
scale batch flotation process of a high grade carbonaceous sedimentary phosphate ore.
The experiments were conducted under different flotation time values (0, 0.75, 1.5, 3 and
ED
6 min). Additionally, the degree of entrainment together with its modelling was studied
using the two most common models (i.e. Savassi and Yianatos). The effect of pulp density
and particle settling velocity on the entrainment was evaluated using Richardson and
PT
Zaki’s approach. The froth characteristics were quantitatively measured using the
dynamic froth analysis (DFA) technique. The liberation degrees of the silicate minerals
E
the surface activity of reagents was characterized with bubble pressure tensiometry.
A
- we have highlighted the significantly changing pulp and froth properties with time
when processing high-grade ores in lab scale batch flotation test work which is
also relevant along with a rougher bank in continuous flotation;
13
- through a combination of time-resolved dynamic froth analysis and automated
mineralogy we have identified the effects governing in the froth with different
flotation times and compared the entrainment results with existing models;
- our analyses offer novel support for the common understanding of the
phenomena of entrained suspended particles within froth lamella.
It was revealed that the froth structure and froth stability (i.e. froth height, bubble size
and liquid content) were significantly altered with respect to decreasing reagent and
particle concentrations during the lab-scale flotation tests. The results show a decreasing
T
entrainment with time for coarse particles due to changing sedimentation of those
IP
hydrophilic silicate particles, increased froth drainage and decreasing stability of the
bubble films in the froth layer. Furthermore, the size of fully liberated silicate particles in
R
the fine fraction was almost constant, while the size of coarser fractions decreased with
flotation time. This effect was only possible to observe through consequent application of
SC
automated mineralogy and, to our best of knowledge, has not been reported before.
Both models of Savassi and Yianatos showed a very good fit to the experimental data for
U
fully liberated silicates. The obtained results showed that not only particle size and
N
density but specifically also the froth and pulp properties should be incorporated in
future entrainment models. The effect of particle size and pulp density on the degree of
A
entrainment might be caused by both factors affecting the sedimentation velocity of
M
gangue particles which has also been identified as an important component in the
fundamental model of Neethling and Cilliers (2009).
ED
Acknowledgments
PT
The authors would like to thank Anja Oestreich for conducting the DFA - 100 and BP - 100
measurements, Thomas Heinig and Sabine Haser for conducting the MLA analysis, as well
E
as Dr. Thomas Leißner from the Institute of Mechanical Process Engineering and Mineral
CC
Furthermore, we would like to thank colleagues at Akzo Nobel, Sweden for their support
A
with flotation reagents supply and discussions.The authors would also like to thank the
anonymous reviewers for their detailed and constructive comments.
14
References
Banhart, J., 2006. Metal Foams: Production and Stability. Advanced Engineering Materials
8, 781-794.
Barbian, N., Hadler, K., Ventura-Medina, E., Cilliers, J.J., 2005. The froth stability column:
linking froth stability and flotation performance. Minerals Engineering 18, 317-324.
Barbian, N., Ventura-Medina, E., Cilliers, J.J., 2003. Dynamic froth stability in froth
flotation. Minerals Engineering 16, 1111-1116.
Bikerman, J.J., 1973. Foams. Springer-Verlag, New York.
Bisshop, J.P., 1974. A Study of Particle Entrainment in Flotation Froths. University of
Queensland.
T
Blümich, B., 1995. P. T. Callaghan. Principles of nuclear magnetic resonance microscopy.
IP
Oxford University Press, Oxford, 1993, 492 pp, £25. ISBN 0 198 53997 5. Magnetic
Resonance in Chemistry 33, 322-322.
R
Blümich, B., 2000. NMR imaging of materials. OUP Oxford.
Boos, J., Drenckhan, W., Stubenrauch, C., 2013. Protocol for Studying Aqueous Foams
SC
Stabilized by Surfactant Mixtures. Journal of Surfactants and Detergents 16, 1-12.
Cantat, I., Cohen-Addad, S., Elias, F., Graner, F., Höhler, R., Pitois, O., Rouyer, F., Saint-
Jalmes, A., Cox, S., 2013. Foams: Structure and Dynamics. 102-110.
U
Cilek, E.C., 2009. The effect of hydrodynamic conditions on true flotation and entrainment
N
in flotation of a complex sulphide ore. International Journal of Mineral Processing 90, 35-
44.
A
Farrokhpay, S., 2011. The significance of froth stability in mineral flotation-a review.
Advances in colloid and interface science 166, 1-7.
M
Geldenhuys, S., McFadzean, B., 2018. Column diameter effects on dynamic froth stability
measurement, International Mineral Processing Congress XXIX, Moscow, Russia.
Heath, J., 2013. Frothing at the lip - stability in your flotation cell - Outotec.
ED
Heitkam, S., Rudolph, M., Lappan, T., Sarma, M., Eckert, S., Trtik, P., Lehmann, E.,
Vontobel, P., Eckert, K., 2018. Neutron imaging of froth structure and particle motion.
Minerals Engineering 119, 126-129.
PT
Hoang, D.H., Kupka, K., Peuker, U.A., Rudolph, M., 2018a. Froth properties and its effect
on lab-scale flotation of a carbonaceous sedimentary apatite ore, International Mineral
Processing Congress XXIX, Moscow, Russia.
E
Hoang, D.H., Kupka, N., Peuker, U.A., Rudolph, M., 2017. Flotation study of a fine grained
CC
15
Laity, P.R., Mantle, M.D., Gladden, L.F., Cameron, R.E., 2010. Magnetic resonance imaging
and X-ray microtomography studies of a gel-forming tablet formulation. European Journal
of Pharmaceutics and Biopharmaceutics 74, 109-119.
Leißner, T., Duong, H.H., Rudolph, M., Heinig, T., Bachmann, K., Gutzmer, J., Schubert, H.,
Peuker, U.A., 2016a. Investigation of mineral liberation by transgranular and intergranular
fracture after milling, IMPC 2016 - 28th International Mineral Processing Congress.
Leißner, T., Hoang, D.H., Rudolph, M., Heinig, T., Bachmann, K., Gutzmer, J., Schubert, H.,
Peuker, U.A., 2016b. A mineral liberation study of grain boundary fracture based on
measurements of the surface exposure after milling. International Journal of Mineral
Processing 156, 3-13.
T
Mackay, I., Mendez, E., Molina, I., Videla, A.R., Cilliers, J.J., Brito-Parada, P.R., 2018.
Dynamic froth stability of copper flotation tailings. Minerals Engineering 124, 103-107.
IP
Marozva, T., 2015. Investigating the effect of frother type on froth stability, froth recovery
and entrainment, Department of Chemical Engineering. University of Cape Town.
R
McFadzean, B., Achaye, I., Chidzanira, T., Harris, M., 2016a. The effect of particle size on
froth stabilities of different ores, XXVIII International Mineral Processing Congress
SC
Proceedings, Quebec, Canada.
McFadzean, B., Marozva, T., Wiese, J., 2016b. Flotation frother mixtures: Decoupling the
sub-processes of froth stability, froth recovery and entrainment. Minerals Engineering 85,
72-79.
U
N
Moolman, D.W., Aldrich, C., van Deventer, J.S.J., Stange, W.W., 1995. The classification of
froth structures in a copper flotation plant by means of a neural net. International Journal
A
of Mineral Processing 43, 193-208.
Neethling, S.J., Brito-Parada, P.R., 2018. Predicting flotation behaviour – The interaction
M
Neethling, S.J., Cilliers, J.J., 2002b. Solids motion in flowing froths. Chemical Engineering
Science 57, 607-615.
Neethling, S.J., Cilliers, J.J., 2009. The entrainment factor in froth flotation: Model for
PT
particle size and other operating parameter effects. International Journal of Mineral
Processing 93, 141-148.
E
Oetjen, K., Bilke-Krause, C., Madani, M., Willers, T., 2014. Temperature effect on
foamability, foam stability, and foam structure of milk. Colloids and Surfaces A:
CC
Pugh, R.J., 1996. Foaming, foam films, antifoaming and defoaming. Advances in colloid
and interface science 64, 67-142.
Pugh, R.J., 2016. Bubble and Foam Chemistry. Cambridge University Press.
Ray, M.S., 1993. Chemical Engineering, Volume 2: Particle Technology and Separation
Processes, 4th edn, by J.M. Coulson and J.F. Richardson. Pergamon Press, Oxford, UK.
1991. 968 pp. ISBN 0‐08‐037957‐5. Developments in Chemical Engineering and Mineral
Processing 1, 172-172.
16
Richardson, J.C., Bowtell, R.W., Mäder, K., Melia, C.D., 2005. Pharmaceutical applications
of magnetic resonance imaging (MRI). Advanced Drug Delivery Reviews 57, 1191-1209.
Richardson, J.F., Zaki, W.N., 1997. Sedimentation and fluidisation: Part I. Chemical
Engineering Research and Design 75, S82-S100.
Ross, V.E., Van Deventer, J.S.J., 1988. Mass transport in flotation column froths, Column
Flotation’88, Phoenix, Arizona, pp. 129–139.
Savassi, O.N., Alexander, D.J., Franzidis, J.P., Manlapig, E.V., 1998. An empirical model for
entrainment in industrial flotation plants. Minerals Engineering 11, 243-256.
Schwarz, S., 2004. The relationship between froth recovery and froth structure, Ian Wark
Research Institute. University of South Australia.
T
Schwarz, S., Grano, S., 2005. Effect of particle hydrophobicity on particle and water
transport across a flotation froth. Colloids and Surfaces A: Physicochemical and
IP
Engineering Aspects 256, 157-164.
Smith, P.G., Warren, L.J., 1989. Entrainment of Particles into Flotation Froths. Mineral
R
Processing and Extractive Metallurgy Review 5, 123-145.
SC
Steinour, H.H., 1944. Rate of sedimentation.Nonflocculated Suspensions of Uniform
Spheres. Industrial & Engineering Chemistry 36, 618-624.
Stock, S.R., 1999. X-ray microtomography of materials. International Materials Reviews
44, 141-164.
U
Stock, S.R., 2008. Recent advances in X-ray microtomography applied to materials.
N
International Materials Reviews 53, 129-181.
Wang, L., 2017. Entrainment of fine particles in froth flotation. The University of
A
Queensland.
M
Wang, L., Peng, Y., Runge, K., Bradshaw, D., 2015. A review of entrainment: Mechanisms,
contributing factors and modelling in flotation. Minerals Engineering 70, 77-91.
Wang, Y., Neethling, S.J., 2009. The relationship between the surface and internal
ED
structure of dry foam. Colloids and Surfaces A: Physicochemical and Engineering Aspects
339, 73-81.
Warren, L.J., 1985. Determination of the contributions of true flotation and entrainment
PT
Wills, B.A., Finch, J.A., 2016. Chapter 12 - Froth Flotation, Wills' Mineral Processing
CC
17
Figures
T
IP
R
SC
Figure 1- A scheme of flotation and sample preparation procedures
U
N
A
M
ED
E PT
CC
A
18
T
IP
Figure 2 - a) Dynamic surface tension as a function of surface age of the pulp and concentrates after various
flotation times b) The change of surface tension at 240 s surface age of pulps and concentrates
with flotation time
R
SC
U
N
A
M
ED
E PT
CC
A
19
T
IP
Figure 3 - Froth height as a function of measuring time during growth of froth of pulp samples at various
flotation times (a) and the froth growth exponential models (b)
R
SC
U
N
A
M
ED
E PT
CC
A
20
T
R IP
Figure 4- Average lifetime of bubble τ and dynamic stability factor ∑ as a function of flotation time (τ and
SC
Hmax from Figure 3b, A= 1256.64 mm2 and Q = 0.5 l/min)
U
N
A
M
ED
E PT
CC
A
21
T
R IP
SC
U
Figure 5 – a) The change of liquid content for the seven sensors of the conductivity electrode (hf=13 mm to
N
133 mm) from the bottom to the top of pulp sample after 0 min flotation time and time
dependence of the liquid content at different froth depths (from the bottom to the top) b) 13 mm,
c) 33 mm, d) 53 mm at various flotation times
A
M
ED
E PT
CC
A
22
T
Figure 6 - Recorded images of the froth structure at different flotation times at camera height of 60 mm, i.e.
froth height from 9.25 mm to 16.75 mm
R IP
SC
U
N
A
M
ED
E PT
CC
A
23
T
R IP
SC
U
N
A
M
Figure 7 – Bubble size evaluation with original frame obtained from DFA 100 a) filtered image b) binarized
image c) and the cell skeleton image d) analyzed bubbles are marked with a circle.
ED
E PT
CC
A
24
T
IP
Figure 8 – Distribution of equivalent radius of bubble size (left) and Sauter mean radius (right) as a function
of flotation time and froth height (the froth heights were calculated from the position of the
R
camera and liquid level). Error bars represent one standard deviation of r32
SC
U
N
A
M
ED
E PT
CC
A
25
T
R IP
Figure 9 - Correlation between the fully liberated silicate particle recovery in different particle size fractions
against the water recovery
SC
U
N
A
M
ED
E PT
Figure 10 - The degree of entrainment for different size fractions of fully liberated silicate particles extracted
CC
from MLA plotted against the mean size for different flotation times
A
26
T
R IP
SC
U
Figure 11 - The fitting curves using Savassi and Yianatos models to the experimental data for different
flotation times (Savassi model: Vg = 2 l/min, Acell= 12,750 mm2, hF=0.5 cm, 𝜉 = 39.14 µm, and
N
Yianatos model: dp,0.5 = 24.71 µm)
A
M
ED
E PT
CC
A
27
T
R IP
SC
U
N
A
Figure 12 a) The format of the equation of fitting curves appear and drainage parameters as a function of
M
pulp density; b) Schematic of a plateau border and its associated lamella (after Ross and Van
Deventer (1988)) and forces acting on a particle at the pulp/froth interface; c) The degree of
entrainment at different flotation times as a function of vsettling
ED
E PT
CC
A
28