0% found this document useful (0 votes)
10 views4 pages

Schneider Electric Acti-9-IC60 A9F04725

The document provides a detailed datasheet for the Acti9 iC60N miniature circuit breaker, specifying its features such as a 25A rated current, 3P+N poles, and various breaking capacities. It outlines compliance with multiple standards, environmental data, and packaging information, while also emphasizing the importance of proper disposal in accordance with EU regulations. Additionally, it mentions Schneider Electric's commitment to sustainability and achieving Net Zero status by 2050.

Uploaded by

Lê Duy Phong
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views4 pages

Schneider Electric Acti-9-IC60 A9F04725

The document provides a detailed datasheet for the Acti9 iC60N miniature circuit breaker, specifying its features such as a 25A rated current, 3P+N poles, and various breaking capacities. It outlines compliance with multiple standards, environmental data, and packaging information, while also emphasizing the importance of proper disposal in accordance with EU regulations. Additionally, it mentions Schneider Electric's commitment to sustainability and achieving Net Zero status by 2050.

Uploaded by

Lê Duy Phong
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Product datasheet

Specifications

Miniature circuit breaker (MCB),


Acti9 iC60N, 3P+N, 25A, C curve,
6000A (IEC 60898-1), 10kA (IEC
60947-2), double term.
A9F04725

Main
Device application Distribution

Range Acti9

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
product name Acti9 iC60

Product or component type Miniature circuit-breaker

Device short name IC60N

Poles description 3P + N

Number of protected poles 3

Neutral position Left

[In] rated current 25 A

Network type DC
AC

Trip unit technology Thermal-magnetic

Curve code C

Breaking capacity 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1


36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2

Utilisation category Category A conforming to EN 60898-1


Category A conforming to IEC 60898-1

Suitability for isolation Yes conforming to EN 60898-1


Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2

Standards EN 60947-2
IEC 60947-2
IEC 60898-1
EN 60898-1

Complementary
Network frequency 50/60 Hz

Magnetic tripping limit 8 x In +/- 20 %

[Ics] rated service breaking 15 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz


capacity 7.5 kA 75 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
4.5 kA 75 % conforming to EN 60947-2 - 440 V AC 50/60 Hz
15 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
7.5 kA 75 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
4.5 kA 75 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz
27 kA 75 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
27 kA 75 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz

15 May 2025 1
Limitation class 3 conforming to EN 60898-1
3 conforming to IEC 60898-1

[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2


500 V AC 50/60 Hz conforming to IEC 60947-2

[Uimp] rated impulse withstand 6 kV conforming to EN 60947-2


voltage 6 kV conforming to IEC 60947-2

Contact position indicator Yes

control type Toggle

Local signalling Trip indicator

Mounting support DIN rail

9 mm pitches 8

Height 91 mm

Width 72 mm

Depth 78.5 mm

Net weight 0.5 kg

Colour White

Mechanical durability 20000 cycles

Electrical durability 10000 cycles

Connections - terminals Double terminal (top or bottom) 1…25 mm² rigid


Double terminal (top or bottom) 1…16 mm² flexible

Wire stripping length 14 mm for top or bottom connection

Tightening torque 2 N.m top or bottom

Earth-leakage protection Separate block

Environment
IP degree of protection IP20 conforming to IEC 60529
IP20 conforming to EN 60529

Pollution degree 3

Overvoltage category IV

Tropicalisation 2

Relative humidity 95 % at 55 °C

Ambient air temperature for -35…70 °C


operation
Ambient air temperature for -40…85 °C
storage

Packing Units
Unit Type of Package 1 PCE

Number of Units in Package 1 1

Package 1 Height 7.000 cm

Package 1 Width 7.500 cm

Package 1 Length 9.000 cm

Package 1 Weight 482.000 g

Unit Type of Package 2 BB1

Number of Units in Package 2 3

2 15 May 2025
Package 2 Height 8.500 cm

Package 2 Width 9.500 cm

Package 2 Length 22.000 cm

Package 2 Weight 1.506 kg

Unit Type of Package 3 S03

Number of Units in Package 3 33

Package 3 Height 30.000 cm

Package 3 Width 30.000 cm

Package 3 Length 40.000 cm

Package 3 Weight 16.963 kg

Contractual warranty
Warranty 18 months

15 May 2025 3
Environmental Data

Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity
via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.

Environmental Data explained

How we assess product sustainability

Environmental footprint

Carbon footprint (kg.eq.CO2 per CR, Total Life cycle) 53

Environmental Disclosure Product Environmental Profile

Use Better

Materials and Substances

Packaging made with recycled cardboard Yes

Packaging without single use plastic Yes

EU RoHS Directive Compliant

SCIP Number 26ff71d1-98cf-4280-8725-455b9a6b2fb9

REACh Regulation REACh Declaration

Halogen content performance Product contains halogen above thresholds

Use Again

Repack and remanufacture

Circularity Profile No need of specific recycling operations

Take-back No

The product must be disposed on European Union


WEEE markets following specific waste collection and never end
up in rubbish bins

4 15 May 2025

You might also like