ÔÇË.
:031-556966 EPLAN HELLAS 031 556966, 526265
Customer :
Plant designation : COMPACT CONTROLLER
Drawing Number : V1.10
Commission :
Manufacture 1 : Control panels :
Incoming supply :
Manufacture 2 : ELECTRONICS & AUTOMATION Feeder :
DEPARTMENT Control Voltage :
Manufacturing date :
Make :
Type :
Installation type :
Particularities : attention!!!goods lift controller-platform-
Special surround. :
Site :
Regulation : MOTORS' SAFETY
Degree of protect. : 20
Created on : 16.Jul.2002
Responsibile for project :
Date changed : 07.Apr.2003 Highest page : 7
Editor : Electronic Controller D.P.T No of pages : 7
it is forbidden to use the present system
in order to carry on this people!!
GOODS LIFT CONTROLLER
T2 T1 A D CV M+ M- KT OL MA1MA2 MA6MA5 MA3MA4 AP AP D12 CV -B +B
RM
0VS
18VS
F5 5X20 2A
F6 5X20 3A
SW1 MK A
C2
RESET A1
C1
REL2
BR1 BR2
220K
LD4 P1
C9
REM
C3
JP3
JP2
JP1
TM
U2 MIK1 K1
C8
BR3
C4 K2
F4 5X20 2A
F1 5X20 2A
F3 5X20 3A
F2 5X20 2A
C7
RL
C6
PIN1
K3
4 CON1 LD2 LD1 LD3
BR4
0V 48V 3
2
REL1
K-D 100 220V N CL CL 1 2 3 4 5 RL1 RL2 θ 7 S1 S2 S3
*
RL'' RL K3 K2 K1
applied rule: FUSES COMPACT RELEY'S COMPACT
LED'S CONTACTS
JP3
JP2
JP1
auto F1 (2A 5x20) General Fuses of 48V circuit REM, K1, K2, K3, RL, A1
LED1 2-3:Door contacts (if available)
F2 (2A 5x20) General Fuses of 48V circuit 48V DC 2 contacts
Manually (3-5: bridged) * F3 (3A 5x20)
F4 (3A 5x20)
Board supply, Shaft switches
Car lights CL
MK, A
48V DC 4 contacts
LED2 1-2:Limit Switch / Emargency stop etc.
When we wish to have "auto" calls REL2 LED3 3-4:Lock contacts (if available)
F5 (2A 5x20) Battery Charger
the jumper JP1 has to be placed, (as F6 (2A 5x20) Retiring CAM, Solenoids 24V DC LED4 2-3:Motor thermal protection P.T.C
the above table shows). RM, TM
Removing it (JP1), platform is "eleven pins" type
moving as long as we keep pushing 3 contacts
the call-buttons (Manually).
EPLAN
0 1 2 3 4 5 6 7 8 9
CONNECTION DRAWING OF MOTOR SUPPLY / THERMISTOR
Τ2 Τ1 CV' W1 V1 U1 L3 L2 L1
PE N
X1 1 2 3 PE
1 F
PTC
2
BUILDING'S CONTROLLER
U1 V1 W1
M 3M
~
PE
REMARK: IN CACE THAT THE THERMAL PROTECTION SYSTEM IN CASE THAT YOU NOTE ATTENTION ! ! !
OF THE MOTOR IS ACTIVATED, IN THE FIRST MOVEMENT WRONG DURING THE TIME YOU EFFECT
THE LED:LD4 BECOMES RED. SENSE OF ROTATION, THE CONNECTIONS,VERIFY THAT
REPAIR THE CAUSE OF THE OVERHEATING REVERSE TWO OF THE THREE THERE IS NO POWER SUPPLY
AND PUSH THE SW1 BUTTON. PHASES OF THE MOTOR ON THE CONTROLLER.
IN NORMAL TEMPERATURE CONDITIONS
THE LED:LD4 IS GREEN
SUPPLY OF(CONTROLLER-MOTOR) SEARCHING: Commission: = +
drawing
DATE: 08.Nov.2002
&THERMAL PROTECTION DRAWING: PROJECT: COMPACT LIFTS
PAGE 2 OF 7
comment
DATE: 04.Sep.2002 DRAWING No:
EPLAN
0 1 2 3 4 5 6 7 8 9
FLOOR SWITCES SAFETIES LINE
7 S3 S2 S1 8 4 3 2 1
S3 S1
LOCKS' DOOR'S EMERGENCY
CONTACTS CONTACTS STOP
TRAVEL'S
LIMITS
SWITCHES
S2 GENERAL
SAFETIES
3rd STOP'S SWITCH 2nd STOP'S SWITCH 1st STOP'S SWITCH
3 STOPS THE CONTACTS ARE NOT USING, ARE BRIDGED
ATTENTION ! ! WE SUGGEST YOU TO
CONNECT NORMALLY ALL THE SAFETIES RULES.
IN CASE THAT YOU HAVE BRIDGED SOME OF
THE ABOVE CONTACTS (2-3 or 3-4)
YOU MUST TAKE ACCOUNT OF
ALL THE NECESSARY SAFEGUARDS
7 S3 S2 S1 8
S3 S1
2nd STOP'S SWITCH 1st STOP'S SWITCH
2 STOPS
FLOOR SWITCHES SEARCHING: Commission: = +
drawing
DATE: 08.Nov.2002
& SAFETIES DRAWING: PROJECT: COMPACT LIFTS
PAGE 3 OF 7
comment
DATE: 04.Sep.2002 DRAWING No:
EPLAN
0 1 2 3 4 5 6 7 8 9
CAR'S LIGHTING MANUAL CAR'S DESCENT SOLENOID'S BLOCK
CL CL AP AP D12 D A CV CV'
BROWN
BLACK
WHITE
BLUE
BLUE
D12 D A
ΜΑΧ 240V AC / 1,6A
380W
EMERGENCY DESCENT ASCENT SOLENOID'S COMMON OF
LOWERING SOLENOID SOLENOID COMMON EMERGENCY
ATTENTION !!! SOLENOID 48V DC 48V DC ASCENT/DESCENT LOWERING
USING THE ABOVE FUNCTION 12V DC ~150 mA ~150 mA SOLENOID
WE SUGGEST YOU
TO TAKE ACCOUNT OF ALL
THE NECESSARY SAFEGUARDS
LIGHTING SEARCHING: Commission: = +
drawing
DATE: 08.Nov.2002
-MANUAL CAR'S DESCENT DRAWING: PROJECT: COMPACT LIFTS
PAGE 5 OF 7
comment
-SOLENOID'S BLOCK DATE: 04.Sep.2002 DRAWING No:
EPLAN
0 1 2 3 4 5 6 7 8 9
CL
CL
BL
OL
7
S3
S2
S1
8
M-
M+
AP
AP
D12
D
A
CV
K3
K2
K1
5
4
3
2
1
T2
T1
CV'
W1
V1
U1
L3
L2
L1
L1 Power supply Κ1 1st Call
OL Light indicator common
Κ2 2nd Call
L2 Power supply
Κ3 3rd Call
BL Busy Light
L3 Power supply CV Solenoids Common
Α Ascent Solenoid
U1 Motor Power supply Τ1
D Descent Solenoid
} Thermal protection Motor
and oil connected in serial
V1 Motor Power supply D12 Emergency Solenoid(+12V) Τ2
Μ+
ΑΡ
W1 Motor Power supply
Μ- } Retiring CAM (if available) ΑΡ
} Emergency Lowering
1* 7 Ascent signal in floor switches
} Safety contacts:Emargency stop,
terminal switches etc. S1 Return of floor switches
Ascent direction arrow
2 Descent direction arrow
Safety contacts:Door contacts
}
3 (if available) *S2
1st level
Return of floor switches
Safety contacts:Lock contacts 2nd level CL Car lights 230V
4 } (if available) **S3 Return of floor switches
3rd level
CL Car lights 230V
5 Call bar (common of calls) 8 Descent signal in floor switches
*if any of the safety chain (1-4) * In case only of 2 levels
does not exist, put a bridge. do not used.
** In case only of 2 levels
*LD1,2,3: Indications of the safety consider S3 as the last level.
lanes:1-2, 2-3, 3-4.
CONNECTION ANALYSIS SEARCHING: Commission: = +
drawing
DATE: 08.Nov.2002
DRAWING: PROJECT: COMPACT LIFTS PAGE 7 OF 7
comment
DATE: 04.Sep.2002 DRAWING No: