01. Fail-safe device must be installed when using the unit with machinery that
Controllers
Failure to follow this instruction may result in personal injury, economic loss or fire.
02. Do not use or store the unit in the place where flammable/explosive/
corrosive gas, high humidity, direct sunlight, radiant heat, vibration, impact
or salinity may be present.
Failure to follow this instruction may result in explosion or fire.
03. Install on a device panel to use.
Failure to follow this instruction may result in fire or electric shock.
04. Do not connect, repair, or inspect the unit while connected to a power
source.
Failure to follow this instruction may result in fire or electric shock.
05. Check ‘Connections’ before wiring.
Failure to follow this instruction may result in fire.
06. Do not disassemble or modify the unit.
Failure to follow this instruction may result in fire or electric shock.
01. When connecting the power input and relay output, use AWG 20 (0.50 mm2)
cable or over, and tighten the terminal screw with a tightening torque of 0.74
to 0.90 N m.
When connecting the sensor input and communication cable without
dedicated cable, use AWG 28 to 16 cable and tighten the terminal screw with
a tightening torque of 0.74 to 0.90 N m.
Failure to follow this instruction may result in fire or malfunction due to contact
failure.
02. Use the unit within the rated specifications.
Failure to follow this instruction may result in fire or product damage
03. Use a dry cloth to clean the unit, and do not use water or organic solvent.
TX Series
Failure to follow this instruction may result in fire or electric shock.
04. Keep the product away from metal chip, dust, and wire residue which flow
into the unit.
PRODUCT MANUAL Failure to follow this instruction may result in fire or product damage.
ᜢᜧᜣᜫ
-|Transparent Guide|-
• Do not apply excessive power when connecting or disconnecting the connectors of the
product.
Specifications
• Install a power switch or circuit breaker in the easily accessible place for supplying or
Series TX Series
disconnecting the power.
Power supply 100 - 240 VACᜠ 50/60 Hz
• Do not use the unit for other purpose (e.g. voltmeter, ammeter), but temperature
Permissible voltage
controller. range
90 to 110 % of rated voltage
• When changing the input sensor, turn off the power first before changing. After changing
Power consumption ≤ 8 VA
the input sensor, modify the value of the corresponding parameter.
Sampling period 50 ms
• Do not overlapping communication line and power line. Use twisted pair wire for
Input specification Refer to 'Input Type and Using Range'.
communication line and connect ferrite bead at each end of line to reduce the effect of
Relay 250 VACᜠ 3 A, 30 VDCᜡ 3 A, 1a
external noise.
Control TX4S: 12 VDCᜡ ±2 V, ≤ 20 mA
• Make a required space around the unit for radiation of heat. For accurate temperature output
SSR
TX4M/H/L: 13 VDCᜡ ±3 V, ≤ 20 mA
measurement, warm up the unit over 20 min after turning on the power.
Current DC 4-20 mA or DC 0-20 mA (parameter), Load resistance: ≤ 500 Ω
• Make sure that power supply voltage reaches to the rated voltage within 2 sec after
Alarm
supplying power. Relay AL1/2: 250 VACᜠ 3 A 1a
output
• Do not wire to terminals which are not used. DC 4 - 20 mA (Load resistance: ≤ 500 Ω, Output Accuracy: ±0.3%
Option PV transmission
• This unit may be used in the following environments. F.S.)
output
- Indoors (in the environment condition rated in ‘Specifications’) RS485 Comm. Modbus RTU
- Altitude Max. 2,000 m Display type 11 Segment (White, Green, Yellow), LCD type
- Pollution degree 2 Control
Heating, Cooling ON/OFF, P, PI, PD, PID Control
- Installation category II type
Hysteresis 1 to 100 (0.1 to 50.0) ℃/℉
Proportional band (P) 0.1 to 999.9 ℃/℉
Ordering Information Integral time (I) 0 to 9,999 sec
Derivative time (D) 0 to 9,999 sec
This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website . Control cycle (T) 0.5 to 120.0 sec
Manual reset 0.0 to 100.0%
T X ❶ ❷ - ❸ ❹ ❺ Relay Mechanical ≥ 5,000,000 operations
life
cycle Electrical ≥ 200,000 operations (resistance load: 250 VACᜠ 3 A)
❶ Display digits ❸ Option in/output
4: 4 digit 1: Alarm 1 Between the charging part and the case: 3,000 VACᜠ 50/60 Hz for
Dielectric strength
1 min
2: Alarm 1 + Alarm 2
A: Alarm 1 + Alarm 2 + PV transmission 0.75 mm amplitude at frequency 5 to 55Hz in each X, Y, Z direction
Vibration
for 2 hours
B: Alarm output 1 + Alarm output 2 + RS485
Insulation resistance ≥ 100 MΩ (500 VDCᜡ megger)
❷ Size ❹ Power supply ±2 kV square shaped noise (pulse width 1 ㎲) by noise simulator
Noise immunity
S: DIN W 48 × H 48 mm 4: 100 - 240 VAC R-phase, S-phase
M: DIN W 72 × H 72 mm ❺ Control output Memory retention ≈ 10 years (non-volatile semiconductor memory type)
H: DIN W 48 × H 96 mm R: Relay Ambient temperature -10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation)
L: DIN W 96 × H 96 mm S: SSR drive Ambient humidity 35 to 85%RH, storage: 35 to 85%RH (no freezing or condensation)
C: Selectable current or SSR drive output Protection structure IP50 (Front panel, IEC standards)
Double or reinforced insulation (mark: ▱, dielectric strength
Insulation type
between primary circuit and secondary circuit: 3 kV)
Product Components Certification ᜢᜧᜣᜫ
• TX4S: ≈ 87 g (≈ 146 g) • TX4M: ≈ 143 g (≈ 233 g)
• Product (+ bracket) • Instruction manual Unit weight (packaged)
• TX4H: ≈ 133 g (≈ 214 g) • TX4L: ≈ 206 g (≈ 290 g)
01) When using the unit at low temperature (below 0℃), display cycle is slow.
Manual
For proper use of the product, refer to the manuals and be sure to follow the safety Communication Interface
considerations in the manuals.
Download the manuals from the Autonics website. ■ RS485
Comm. protocol Modbus RTU
Application standard EIA RS485 compliance with
Software Maximum connection 31 units (address: 01 to 127)
Download the installation file and the manuals from the Autonics website. Synchronous method Asynchronous
Comm. method Two-wire half duplex
■ DAQMaster Comm. effective range ≤ 800 m
DAQMaster is comprehensive device management program. It is available for
Comm. speed 2,400 / 4,800 / 9,600 (default) / 19,200 / 38,400 bps (parameter)
parameter setting, monitoring.
Response time 5 to 99 ms (default: 20 ms)
Start bit 1 bit (fixed)
Sold Separately Data bit 8 bit (fixed)
Parity bit None (default), Odd, Even
• Terminal protection cover: RSA / RMA / RHA / RLA-COVER Stop bit 1 bit, 2 bit (default)
• Communication Converter: SCM-USP / SCM-38I / SCM-US48I / SCM-WF48
-|Transparent Guide|-
I
L (IC) H
LIcH
-couple 0.1 -40.0 to 800.0 -40.0 to 999.9
G
B
LIcL
E
1 -50 to 400 -58 to 752
T (CC)
TCcH
0.1 TCcL -50.0 to 400.0 -58.0 to 752.0
R (PR) 1 RPR 0 to 1,700 32 to 3,092
S (PR) 1 SPR 0 to 1,700 32 to 3,092
1 -50 to 200 -58 to 392 Body Panel cut-out
Cu50 Ω
CUsH
0.1 -50.0 to 200.0 -58.0 to 392.0 A B C D E F G H I
RTD
CUsL
1 -100 to 400 -148 to 752 TX4S 48 48 6 45 44.8 ≥ 65 ≥ 65 45+00.6 45+00.6
DPt100 Ω
DPtH
0.1 -100.0 to 400.0 -148.0 to 752.0
TX4M 72 72 6 45 67.5 ≥ 90 ≥ 90 68+00.7 68+00.7
DPtL
3.5
temperature Over 200 ℃:
(23℃ ±5 ℃) (PV ±0.5% or ±2℃ higher one) ±1digit
Thermocouple • Thermocouple L, RTD Cu50 Ω:
4
RTD (PV ±0.5% or ±2 ℃ higher one) ±1-digit 46 8.5
(PV ±0.5% or ±2 ℃ higher one) ±1-digit
Out of room • Thermocouple R, S:
temperature (PV ±1.0% or ±5 ℃ higher one) ±1digit
33
range • Thermocouple L, RTD Cu50 Ω:
11.9
(PV ±0.5% or ±3 ℃ higher one) ±1digit
23.9
5. PC loader port: F
or connecting communication converter
(sold separately).
Errors
Display Description Troubleshooting
Flashes when input sensor is disconnected or
Check input sensor status.
sensor is not connected.
OPEN
≥3.0 ≥3.0
≤5.8 ≤5.8
■ Parameter 2 group
Function: Alarm
Parameter Display Default Setting range Condition
Input
2-1 IN-T KCaH Refer to 'Input Type and Using Range' - Set both alarm operation and alarm option by combining.
specification 01)
88* 8 Each alarm operates individually in two alarm output models.
Temperature Alarm Alarm
2-2 ?C ℃, ℉ - When the current temperature is out of alarm range, alarm clears
unit 01)
UNIT
operation option automatically.
Input
2-3 0 -999 to 999 (-199.9 to 999.9) ℃/℉ -
correction
■ Operation
IN-B
• H: Alarm output hysteresis
Input digital
2-4 )1 0.1 to 120.0 sec -
filter Mode Name Alarm operation Description
MAvF
2-5 SV low limit 02) L-SV -50 Within '2-1 Input specification: using range' - AM0 - - No alarm output
L-SV ≤ H-SV - 1-digit ℃/℉
2-6 SV high limit 02) H-SV 1200 H-SV ≥ L-SV + 1-digit ℃/℉ - If deviation between PV
Control output
OFF H ON OFF H ON and SV as high-limit is
2-7 O-FT HEAT HEAT: Heating, COOL: Cooling - Deviation higher than set value of
mode SV PV PV SV
high limit deviation temperature,
AM1
2-8 Control type 03) PID PID, ONOF : ON/OFF - 100℃ 110℃ 90℃ 100℃
the alarm output will be
C-MD
[Selectable current or SSR drive output
2-9 Control output - High deviation: Set as 10℃ High deviation: Set as -10℃ ON.
model] CURR: Current, SSR
OUT CURR
SSR drive [SSR drive output model] If deviation between PV
2-10 - ON H OFF ON H OFF and SV as low limit is
output type STND, CYCL, PHAS
SSrM STND
2-9 Control Deviation higher than set value of
Current output PV SV SV PV
low limit deviation temperature,
AM2
2-11 4-20 4-20: 4-20 mA, 0-20: 0-20 mA output: 90℃ 100℃ 100℃ 110℃
range
oMA
CURR the alarm output will be
2-8 Control Low deviation: Set as 10℃ Low deviation: Set as -10℃ ON.
type: PID If deviation between
2)0
(Relay)
2-12 Control cycle 0.5 to 120.0 sec or 2-10 SSR ON H OFF H ON PV and SV as high/low-
Deviation
T
@0 drive output limit is higher than
(SSR) type: STND high, low PV SV PV
set value of deviation
AM3
90℃ 100℃ 110℃
□□□
limit
temperature, the alarm
AM0: Off High, Low deviation: Set as 10℃ output will be ON.
AM1: Deviation high limit alarm If deviation between
AM2: Deviation low limit alarm OFF H ON H OFF PV and SV is higher
AL1 alarm AM3: Deviation high, low limit alarm
2-13 - Deviation than the lower limit
operation AM4: Deviation high, low reverse alarm PV SV PV
high, 90℃ 100℃ 110℃ deviation set value
AM5: Absolute value high limit alarm
low limit and less than the
AM4
AM6: Absolute value low limit alarm
reverse upper limit deviation
AM!A SBA: Sensor break alarm
High, Low deviation: Set as 10℃ set value, the alarm
□□□.■ LBA: Loop break alarm (LBA)
AL-1
output will be ON.
■
A: Standard alarm B: Alarm latch OFF H ON OFF H ON
C: S
tandby D: Alarm latch and Absolute If PV is higher than the
AL1 alarm sequence 1 standby sequence 1 AM5 value high PV SV SV PV absolute value, the
2-14 - 90℃ 100℃ 100℃ 110℃
option E: S
tandby F: A
larm latch and limit output will be ON.
Absolute value: Set as 90℃ Absolute value: Set as 110℃
sequence 2 standby sequence 2
• Enter to option setting: Press [◀] key in ON H OFF ON H OFF
Absolute If PV is lower than the
2-13 AL-1 alarm operation.
value low PV SV SV PV absolute value, the
AL2 alarm
AM6
90℃ 100℃ 100℃ 110℃
2-15 [Alarm output2 model] limit output will be ON.
operation Absolute value: Set as 90℃ Absolute value: Set as 110℃
AM@A Same as '2-13/14 AL1 alarm operation/ -
AL2 alarm
AL-2
2-16 option' It will be ON when
option Sensor
- it detects sensor
2-13/14 break
SBA
disconnection.
Alarm output AL1/2 alarm
2-17 1 1 to 100 (0.1 to 50.0) ℃/℉ It will be ON when
hysteresis operation:
AHYS
Loop
AM1 to 6 - it detects loop
break
LBA
2-13/14 disconnection.
AL1/2 alarm
2-18 LBA time LBaT 0 0 (OFF) to 9,999 sec or auto 04)
operation: ■ Option
LBA
Condition
2-13/14 Mode Name Description
of reapply
AL1/2 alarm
operation: Standard If it is an alarm condition, alarm output is ON. If it is a clear
2-19 LBA band 2 0 (OFF) to 999 (0.0 to 999.9) ℃/℉ or auto 05) -
alarm alarm condition, alarm output is OFF.
A
LBA & 2-18
LBaB
LBA time: > If it is an alarm condition, alarm output is ON and
Alarm latch -
0 maintains ON status.
B
Transmission First alarm condition is ignored and from second alarm
2-20 output low FS-L -50 condition, standard alarm operates. When power is
limit [PV transmission output model] Standby
- supplied and it is an alarm condition, this first alarm
sequence 1
C
Transmission Refer to 'Input Type and Using Range' condition is ignored and from the second alarm
2-21 output high FS-H 1200 condition, standard alarm operates.
limit Power ON
If it is an alarm condition, it operates both alarm latch
Comm. [Communication output model] Alarm
2-22 - and standby sequence. When power is supplied and
address 1 to 127 latch and
ADRS 1
it is an alarm condition, this first alarm condition is
[Communication output model] standby
D
2-23 Comm. speed - ignored and from the second 1alarm condition, alarm
24, 48, 96, 192, 384 (×100) bps sequence 1
BPS 96
latch operates.
Comm. parity [Communication output model]
2-24 - First alarm condition is ignored and from second
bit NONE, EVEN, ODD
PRTY NONE
[Communication output model] alarm condition, standard alarm operates. When re- Power ON,
2-25 Comm. stop bit - Standby
STP 2
1, 2 bit applied standby sequence and if it is alarm condition, change SV,
sequence 2
E
[Communication output model] alarm output does not turn ON. After clearing alarm change
2-26 Response time - condition, standard alarm operates. alarm
5 to 99 ms
RSwT 20
[Communication output model] Basic operation is same as alarm latch and standby temperature
2-27 Comm. write - / operation
EN.A: Enable, DIS.A: Disable Alarm sequence1. It operates not only by power ON/OFF,
COMW EnA
Digital input STOP: Stop control output, AL.RE: Alarm *2-8 Control latch and but also alarm set value, or alarm option changing. or change
2-28 STOP to RUN
key reset, AT*: Execute auto tuning, OFF type: PID standby When re-applied standby sequence and if it is alarm
DI-K STOP F
2-8 Control sequence 2 condition, alarm output does not turn ON. mode
0.0: OFF, 100.0: ON
Sensor error, type: ONOF After clearing alarm condition, alarm latch operates.
2-29
MV 2-8 Control
ErMV )0
0.0 to 100.0%
type: PID
OFF
LOC1: Lock parameter 2 group
2-30 Lock LOC OFF LOC2: Lock parameter 1/2 group -
LOC3: Lock parameter 1/2 group, SV
setting
01) B
elow parameters are initialized when the setting value is changed.
- Parameter 1 group: AL1/2 alarm temperature,
- Parameter 2 group: Input correction, SV high/low limit, LBA band, Alarm output Hysteresis
02) If SV is lower/higher than low/high limit when the value is changed, SV is changed to the low/high limit value.
03) W
hen changing the value from PID to ONOF, each value of following parameter is changed.
2-28 Digital input key: OFF, 2-29 Sensor error, MV: 0.0 (Setting value is lower than 100.0)
04) A
fter auto tuning, the range is set as twice of the integral time automatically. If the previous setting value is
outside of the range automatically set, it is set to the nearest Max. or Min. value of the range.
05) A
fter auto tuning, the range is set as 10% of the proportion band automatically. If the previous setting value is
outside of the range automatically set, it is set to the nearest Max. or Min value of the range.
-|Transparent Guide|- -
UP
68.5
41
45
64
DOWN
DOWN
18
22
13
RHA-COVER: DIN W48 × H96 RLA-COVER: DIN W96 × H96
3.8 47.2 9 3.8 94 10
UP UP
91.5
91.5
DOWN
86
86
UP
DOWN DOWN
13
13
Segment Table
The segments displayed on the product indicate the following meanings. It may differ
depending on the product.
7 Segment 11 Segment 12 Segment 16 Segment
0 0 I I 0 0 I I 0 0 I I 0 0 I I
1 1 J J 1 1 J J 1 1 J J 1 1 J J
2 2 K K 2 2 K K 2 2 K K 2 2 K K
3 3 L L 3 3 L L 3 3 L L 3 3 L L
4 4 M M 4 4 M M 4 4 M M 4 4 M M
5 5 N N 5 5 N N 5 5 N N 5 5 N N
6 6 O O 6 6 O O 6 6 O O 6 6 O O
7 7 P P 7 7 P P 7 7 P P 7 7 P P
8 8 Q Q 8 8 Q Q 8 8 Q Q 8 8 Q Q
9 9 R R 9 9 R R 9 9 R R 9 9 R R
A A S S A A S S A A S S A A S S
B B T T B B T T B B T T B B T T
C C U U C C U U C C U U C C U U
D D V V D D V V D D V V D D V V
E E W W E E W W E E W W E E W W
F F X X F F X X F F X X F F X X
G G Y Y G G Y Y G G Y Y G G Y Y
H H Z Z H H Z Z H H Z Z H H Z Z