05092016_gmi_shortform_web (1)
05092016_gmi_shortform_web (1)
History
In 1970 Glisente Landrini founded Elcon Instruments, which has been
acknowledged as an international leader in the design and manufacturing of
Intrinsically Safe products and systems.
Mr. Landrini started G.M. International to provide state of the art SIL rated
products and services to support Intrinsically Safe applications in Oil & Gas,
Petrochemical and Pharmaceutical Industries.
The Company was founded in 1993, but the core Management experience
remarkably exceeds over 40 years of qualified activity in hazardous locations
and industrial electronics. Glisente Landrini
President and Managing Director
G.M. International’s products have been successfully installed in plants all over the
world, including Europe, Russia, North America, Middle and Far East and China.
G.M. International’s products interface all wiring between safe and hazardous
areas and represent a fundamental, yet often under-estimated, layer of the
instrumentation package.
Intrinsically Safe isolators provide energy limitation to protect from risks of
explosion while providing the highest grade of availability to guarantee both
continuous operation and effectiveness of the safety layer.
G.M. International has obtained SIL 3 FSM approval by TÜV according to
IEC61508:2010 standard, and its products are certified up to SIL3, offering the
greatest levels of functional safety for high integrity and critical applications.
2
Headquarters in Italy
Code of Ethics
All personell is highly qualified, experienced and continuously trained.
G.M. International employees adhere to a strict code of ethics approved by the
Board of Directors.
3
COMPANY PROFILE
MANUFACTURING EXCELLENCE
Laser Marking
All markings are engraved using a state-of-the-art laser etching machine;
permanent in every environmental condition.
Marking includes complete wiring diagrams, terminal block number
assignments and certification data.
Product Traceability
All products follow a strict traceability standard. From the batch of components
to customer assignment through every manufacturing and testing steps, all
data of individual modules are stored.
Starting from the serial number, the complete history of any module can be
traced through all production phases.
Protective G3 Coating
All units are treated with a “G3” compliant silicon based coating.
Such tropicalization is applied to improve electrical characteristics, as well as to
protect from harsh environmental conditions.
4
MANUFACTURING EXCELLENCE
C D
Made in Italy
The whole product range are proudly assembled, calibrated and tested in our
own facilities in Villasanta, near Milan in ITALY, utilizing the latest technologies
and machinery.
Manufacturing Facilities
Having complete control on the manufacturing process ensures the highest level
of quality and guarantees the greatest flexibility for all customers’ requirements
with improved delivery time for large or small orders alike.
Manufacturing equipments are constantly renewed and updated;
Automatic Test Equipment, specifically developed by our engineering team,
are constantly checked and calibrated against traceable standards to ensure
accuracy and repeatability.
The entire manufacturing process is SIL 3 certified by TÜV.
100 % Testing
Each and every manufactured product undergoes rigorous and automated
test and calibration procedures. Test bench calibration is verified several times
during the day to guarantee correct and repeatable results. Product field return A. G3 Coating
rate, verified according to ISO 9000:2008 records, is lower than 0.1%. B. Assembly Line
C. Automated Pick and Place
D. Visual Inspection
5
COMPANY PROFILE
B C
INNOVATION
Design
D5000 and D6000 series modules use embedded Planar Transformers to
guarantee the greatest reliability, accuracy and stability, as well as
low manufacturing costs.
We strive to use the best industry components, qualified as a minimum for
operations up to 85°C, and use advanced designed techniques to improve
performances and quality. D5000 series does not use electrolytic capacitors and
has obtained TÜV certification for 20 years lifetime.
Assembly Technology
We make use of the latest assembly technology such as SMD mounting of most
components including terminal blocks and transformers.
Soldering is performed using reflow technology, industry highest standard.
Automatic optical verification of all assembled plates is performed at the end of
the assembly process to eliminate all flaws at the earliest stage.
6
INNOVATION
Quality
Quality is crucial to achieve customer satisfaction and market success.
G.M. International’s products satisfy customers’ expectations and meet the
specifications of international standards.
Safety, performance, reliability and product documentation are the basic principles
of product quality. G. M. International has obtained ISO 9001:2008 in 2006.
7
COMPANY PROFILE
Customer Support
G.M. International considers service as an integral part of customer’ s
requirements and satisfaction.
Among the services we offer:
• Cabinet assembly according to customer’s specification and worldwide
EX standards
• System Engineering
• Custom solutions tailored to customer’s special requests
• ISO 9000:2008 certified post sales assistance service
• Factory Acceptance Tests (FAT) on products and assembled cabinets that can
be staged in our facilities in Villasanta (MB) – Italy, at any of our subsidiaries
or in the facilities of our worldwide system integrator partners
8
TRAINING AND DEVELOMPMENT
Customer Training
Special courses for engineering companies, end users and system integrators
are also given both in-house and at customers sites on topics such as Intrinsic
Safety (I.S.) and SIL levels of a Safety Instrumented System (SIS). Specifically, our
SIL courses based on our SIL manual, have proven to be highly informative and
have gained strong popularity.
G.M. International is a course promoter of the TÜV Rheinland Functional Safety
Program for Safety Instrumented Systems (SIS) trainings, see our website for
available dates. The main objective is to provide engineers involved in safety
instrumented systems with elementary and necessary knowledge of functional
safety, based on IEC61508 and IEC61511.
9
CERTIFICATIONS
10
WORLDWIDE
LYON
MILAN
TEHERAN TOKYO
SHANGAI
HOUSTON DUBAI
SINGAPORE
WORLDWIDE PRESENCE
We are there, wherever you need
G.M. International provides local pre and post sales support through its 7 direct
subsidiaries and numerous agents and distributors in more than 55 countries.
Our authorized sales network ensures a fast response wherever you are.
Visit our website www.gmintsrl.com to find an expert near you and take advantage
of a global partnership with G.M. International.
11
12
D2000 SERIES
Enhanced Intrinsically
Safe Isolators
D5000
Intrinsically Safe
Isolators
D1000
Intrinsically Safe
Multiplexer System
D2000
Surge Arresters
D9000
Intrinsically Safe
Loop Indicator
T3000
PRODUCTS
13
PRODUCTS
OVERVIEW
Get inspired!
Visit our website for further information: www.gmintsrl.com
14
PRODUCTS
ICONS
The following is a descriptive list of the icons that appear in this section:
5+.
MODBUS
Transmitter Switch or Proximity Safety Relay SIL 3 Level according to
IEC 61508, IEC 61511
Load Cell
Current Signal Strain Gauge Fire and Gas System Diagnostics available
Thermocouple or MODBUS
RTD 4-wires Vibration Sensor Visual Alarm MODBUS RTU available
Thermocouple or
RTD 3-wires
RS-485
RS-422 Serial Comunication
Protocol Audible Alarm
TB Only for Termination
Board
D2010M
Thermocouple or D2030M For connection to field Isolated AC/DC
Voltage Signal units D2010M, D2030M Power Supply Configurable via PC
Isolated AC/DC
RTD 3-wires Power Supply
Electrovalve
LED
Switch-over Relay
15
PRODUCT SELECTOR
D5030
D5032
Relay D5036
output D1030
D1032
D1080
D5031
D5035
D5037
Transistor D5231
24 Vdc
output D1031
D1033
D1035
D1081
No Line
Current D5034
Monitoring
output D1034
D1130
115-230
Vac
D1180
D5030
D5032
Relay
D5036
output
D1030
Relay D5037D
output D1030S
D1032D
Remote
Line
alarm or D5031D
Monitoring
duplicator
D5037D
Transistor
D5231
output
D1031D
D1033D
D5034
Transistor
Transparent
output
D1034
16
PRODUCT SELECTOR
D5040
D1040
Loop DC NE/ND
output D1041
powered load
D1042
D1043
D5240
No Line D1040
I.S.
Monitoring
D1041
NE/ND
DC output D1042
load
D1043
24 Vdc D1045
D1046
Relay D5244
output D1044
DIGITAL
OUTPUT
Loop D5048
DC output NE/ND load
powered D1048
I.S.
24 D5049
DC output NE/ND load
Vdc D1049
D5293
Line NE load
Monitoring D1093
D5294
Non Relay
24 Vdc ND load D5096
I.S. output
D1093
17
PRODUCT SELECTOR
D5011
D5014
D5015
D5212
D1010
D1012
D1014
D5254
+ Alarm
D1054
D5014D
D5015D
Duplicator D1010D
ANALOG D5212
INPUT D1012
D5014
D5014
D1010
4 Wire D5254
ĐƟǀĞdx + Alarm
D1054
D1053
D5014D
Duplicator D5015D
D1010D
D5020
24 Vdc
No Line D1020
Monitoring
Loop
D1022
powered
ANALOG
OUTPUT
Open/short
D5020
circuit
4 Wire
24 Vdc
Tx
Open circuit D1020
D5072
D1072
D5273
TC, RTD, Pot + Alarm
D1073
TEMPERATURE D5072D
Duplicator
D1072D
18
PRODUCT SELECTOR
D5263
Transparent
D1063
D5035
D1035
FREQUENCY
D5060
Analog out + Alarm
D1060
D5062
VIBRATION
D1062
ND D5294
Load D5295
FULL
ĚŝĂŐŶŽƐƟĐ D5293
NE D5294
ŝĂŐŶŽƐƟƐĐ Load
D5295
D5096
Line monitoring NE/ND
D5097
only Load
D1093
D5090-086
SAFETY D5091
RELAY D5094
OUT
ND D5095
Load D5290-078
D5291
D1092
D1092-069
No D5090
ŝĂŐŶŽƐƟĐƐ D5094
D5095
D5098
D5290
D5290-078
NE
Load D5290-079
D5290-080
D5290-084
D5290-091
D5290-092
D1092
D1092-069
19
20
D5000 SERIES
D5000
SERIES
ENHANCED INTRINSICALLY SAFE ISOLATORS
SUITABLE FOR SIL 2 AND SIL 3 APPLICATIONS
21
D5000 Termination Board connector
CHARACTERISTICS
Power Bus connector
120 mm
D5200
DIMENSIONS
123 mm
22.5 mm
22
D5000 SERIES
23
D5000 SERIES
FEATURES
Blue Terminal Blocks Grey Terminal Blocks Enclosure Characteristics
for Hazardous Area for Safe Area
connections connections • High channel density result from innovative circuit
design using advanced surface mount components
• Plug-in screw terminal blocks to secure termination
up to 2.5 mm2
• Configuration components are easily accessed by
removing side cover
24
D5000 SERIES
TERMINATION BOARDS
Characteristics
• Suitable to host 8/16/32 D5000 or D5200 SIL 3 modules
12.5mm/22.5mm wide, single or double channel, for up to a total
of 32 channels
• AI - AO - DI - DO Temperature: single or double channels
• Signal converter, Safety Relay: single channel
• 24 Vdc redundant power supply, with window voltage monitoring
and corresponding relay fault output
• Boards are available with custom connectors to directly interface
any system PLC / DCS / ESD
• Cumulative fault relay output
16 ch output connector
Power ON LEDs 1 - 2
Fault signaling LEDs
25
D5000 SERIES
CONFIGURATION
SWC5090 Software
SWC5090 software is designed to provide a PC user interface to configure
suitable D5000, D5200 modules, via PPC5092 adapter.
26
D5000 SELECTION TABLE
5+.
D5011S 1 MODBUS
4-20 mA
4-20 mA 24
2-Wires Passive Tx
(source) Vdc
Smart compatible 5+.
D5011D 2 MODBUS
5+.
D5014S 1 MODBUS
4-20 mA
4-20 mA (source or sink)
2-Wires Passive Tx + 1-5 V (not SIL) 5+.
24 MODBUS
D5014D 4-Wires Active Tx 2
Smart compatible
Vdc
Two 1 in 5+.
D5014D MODBUS
duplicated outputs 2 out
4-20 mA
D5015SS 1
(source)
ANALOG IN
4-20 mA
D5015SK 1
(sink)
4-20 mA
D5015DS 4-20 mA 2
(source)
2-Wires Passive Tx 24
4-Wires Active Tx Vdc
Smart compatible 4-20 mA
D5015DK 2
(sink)
Two 1 in
D5015DS
duplicated outputs 2 out
Two 1 in
D5015DK
duplicated outputs 2 out
27
D5000 SELECTION TABLE
D5072S 24
2/3/4-Wires RTD 2/3/4-Wires RTD 1
-087 Vdc
D5020S 4-20 mA 1
Analog Signal to I/P
Bus powered
Converters, 24
signal from DCS, PLC or
Electrovalves, Vdc
other control devices.
D5020D Actuators and Displays; Two duplicated outputs. 2
Smart compatible
5+.
D5040S 1 MODBUS
NE solenoid valve,
Loop Powered control
signal from safety Loop
other control devices.
PLC, DCS 5+.
D5040D 2 MODBUS
Loop Powered control 5+.
NE solenoid valve,
DIGITAL OUTPUT DRIVER
28
D5000 SELECTION TABLE
29
D5000 SELECTION TABLE
Isolated inputs
Voltage free
D5037S Contact, 1
Proximity Switch SPST (relay contact) 24
Line fault + LED (fault status) Vdc
D5037D detection 2
Isolated inputs
0-50 KHz
Magnetic Pickup mA (source), 24
CONVERTERS
D5060S 1
or Pulse repeater Output Vdc
SIGNAL
Proximity Switch
4-20 mA / 0-20 mA 4-20 mA / 0-20 mA
(source/sink) 24
D5254S 2/4 wires Tx + 2 independent alarms via 1
Vdc
0.3 V to ± 30 V SPDT relays + Modbus
Vibration
INTERFACE
VIBRATION
Transducers, Transparent 24
D5062S 1
Accelerometers, input repeater Vdc
2/3-Wires sensors
mA (source/sink)
ISOLATOR CONV.
LOAD CELLS
for more information and details about Power Supplies, see section at page 75
SAFETY
RELAYS
for more information and details about Safety Relays, see section at page 33
30
D5000 ACCESSORIES
MOR015 Plug-in terminal block male, vertical out, for Power Bus.
MOR017 Plug-in terminal block male, horizontal out, for Power Bus.
MOR022 Plug-in terminal block female, horizontal out, for Power Bus.
31
32
SAFETY
RELAYS
HIGH INTEGRITY SAFETY RELAYS
SUITABLE FOR SIL 3 APPLICATIONS ACCORDING TO IEC61508
33
SAFETY RELAYS
CHARACTERISTICS
Introduction
When a load cannot be driven directly by a safety
controller, an interposing relay becomes a requirement.
For example, if the controller cannot handle the
amount of power required to switch the load; or the
voltage is different from 24 Vdc; or multiple contacts
are required to be driven by the same control signal.
SIL certified safety relays are a requirement to meet
the necessary Risk Reduction Factor (RRF) when
switching a load ON or OFF, in an IEC61508/61511
Safety Instrumented Function (SIF). SIL certified
relays guarantee that the safety function is met with a
suitable and known probability of failure (PFD).
The market for SIL certified relays is growing very
fast in all fields and applications and is no longer
an exclusivity of the Oil & Gas sector, thanks to
the increased implementation of functional safety
standards. Controls and braking systems for trains are
an example.
Safety Function
In order to properly select a SIL relay, special attention Combinations:
must be given to the Safety Function (SF) of the SIF Sometimes the relay function must be inverted to
where the SIL relay will be used, since different relay achieve the required SF. Meaning that the control
matrixes are used to achieve the required Safety signal is 1 but the load must be 0, or vice versa.
Integrity Level.
The two most typical SFs are De-Energize to Trip (DTS)
and Energize to Trip (ETS), however, combinations of
the two are also possible. Applications
DTS:
Used mostly in ESD systems to disconnect power Some of the most common applications for a SIL 2 or
to safety valves which are Normally Energized; SIL 3 relay are the controlling of:
it is achieved by removing power to the load through • Solenoid Valves (SOV) in ESD and F&G systems
the opening of the DO signal (0 Volts or “0”) and the • Beacons, Horns, and similar signaling devices
consequential opening of the relay contacts. • Burner Management Systems (BMS)
• AC or DC Motors
ETS:
Used mostly in F&G systems to energize deluge valves SIL certified relays are also used for feedback signals
which are Normally De-Energized or dormant; it is and as interposing relays between different systems.
achieved by providing power to the load through
the closing of the DO signal (24 Volts or “1”) and the
consequential closing of the relay contacts.
34
SAFETY RELAYS
D5294S
35
SAFETY RELAYS
FIELD
diagnostics
24 Vdc
From 24 Vdc
up to 250 Vac
DCS/PLC DI
(2 dry contacts)
DCS/PLC DO
diagnostics
configuration
36
SAFETY RELAYS SELECTION TABLE
D5090S
5A
PLC
Output ON
250 Vac
Service NE
PLC
Service 24 Vdc 1250 VA
Output ON 5+.
Load Load Load MODBUS
24 Vdc
(Not SIL) SIL 3 (Not SIL)
5A
NE
Load
250 Vdc
SIL 3 140 W
- / AC - / AC 24 Vdc
Coil
Normal Operation: NE Relay Coil and NE Load (1-1).
Safe State: Load is disconnected by disconnecting input (0-0).
+ / AC + / AC
D5090S-
5A
086 PLC 250 Vac
Output OFF
Service NE
PLC
Service 0 Vdc 1250 VA
Output OFF 5+.
Load Load Load MODBUS
0 Vdc
(Not SIL) SIL 3 (Not SIL)
5A
NE 250 Vdc
Load
SIL 3 140 W
- / AC - / AC 24 Vdc
Coil
Normal Operation: ND Relay Coil and NE Load (0-1).
SAFETY RELAYS
+ / AC + / AC
D5091S
5A
250 Vac
PLC PLC
Output OFF Output ON 1250 VA 5+.
0 Vdc 24 Vdc MODBUS
5A
ND ND
Load
Service Load Service Load Load 250 Vdc
SIL3 SIL3
140 W
- / AC - / AC
24 Vdc
Coil
Normal Operation: ND or NE Relay Coil and ND Load (0-0 or 1-0).
Safe State: Load is connected by connecting input (1-1) or
by disconnecting input (0-1).
+ / AC + / AC
D5094S
Out 1 Out 1
5A
PLC PLC
250 Vac
NE F&G/ND
Output ON Load Service Output OFF Load Service 1250 VA
24 Vdc SIL 3 Load 0 Vdc SIL 3 Load 5+.
(Not SIL) (Not SIL) MODBUS
Out 2 Out 2
5A
250 Vdc
140 W
- / AC - / AC
24 Vdc
Normal Operation: NE Relay Coil and NE Load (1-1) or Coil
ND Relay Coil and F&G/ND Load (0-0).
Safe State: Load is disconnected by disconnecting input (0-0) or
Load is connected by connecting input (1-1).
37
SAFETY RELAYS SELECTION TABLE
5A
250 Vac
PLC NE PLC F&G/ND
Output OFF Load Service Output ON Load Service 1250 VA
0 Vdc SIL 3 Load 24 Vdc SIL 3 Load 5+.
(Not SIL) (Not SIL) MODBUS
Out 2 Out 2
5A
250 Vdc
140 W
- / AC - / AC
24 Vdc
Normal Operation: ND Relay Coil and NE Load (0-1) or Coil
NE Relay Coil and F&G/ND Load (1-0).
Safe State: Load is diconnected by connecting input (1-0) or
Load is connected by disconnecting input (0-1).
+ / AC + / AC
D5096S
5A
PLC NE PLC F&G/ND 250 Vac
Output ON Load Service Output OFF Load Service 5+.
24 Vdc SIL 3 Load 0 Vdc SIL 3 Load 1250 VA MODBUS
(Not SIL) (Not SIL)
5A
250 Vdc
- / AC - / AC
140 W
D5097S
5A
PLC NE PLC F&G/ND 250 Vac
Output OFF Load Service Output ON Load Service 5+.
1250 VA MODBUS
0 Vdc SIL 3 Load
(Not SIL)
24 Vdc SIL 3 Load
(Not SIL)
5A
250 Vdc
- / AC - / AC 140 W
D5098S PLC 5A
Output ON
24 Vdc 250 Vac
1250 VA
Service 5+.
Load MODBUS
(Not SIL)
5A
NE 250 Vdc
Load
SIL 3 140 W
- / AC 24 Vdc
Coil
Normal Operation: NE Relay Coil and NE Load (1-1).
Safe State: Load is disconnected by disconnecting input (0-0).
38
SAFETY RELAYS SELECTION TABLE
- / AC - / AC 24 Vdc
Coil
Normal Operation: Dual channel. NE Relay Coil and NE Load (1-1).
Safe State: Load is disconnected by disconnecting input (0-0).
+ / AC + / AC
D5290S
10 A
PLC 250 Vac
Output ON
PLC 24 Vdc 2500 VA
Service NE Output ON Service 5+.
Load Load Load MODBUS
(Not SIL) SIL 3
24 Vdc
(Not SIL)
10 A
NE 250 Vdc
Load
SIL 3 300 W
- / AC - / AC 24 Vdc
SAFETY RELAYS
Coil
Normal Operation: NE Relay Coil and NE Load (1-1).
Safe State: Load is disconnected by disconnecting input (0-0).
+ / AC + / AC + / AC
D5290S
5A
-078 PLC
250 Vac
Output OFF
- / AC - / AC - / AC 24 Vdc
Coil
NE or ND Relay Coil and NE-ND or ND Load for interrupting up to 4 loads.
SIL 3 function: configurable via external wiring.
+ / AC + / AC + / AC + / AC
D5290S
5A
-079 250 Vac
PLC
Service
NE
PLC
NE Service
Output ON 1250 VA
Load Output ON 115 Vac
(Not A Load Load B Load
115 Vac (Not SIL)
SIL) SIL 3 SIL 3
Service Service 5A 5+.
ND MODBUS
Load
SIL 3
A Load
(Not SIL)
Load
(Not SIL)
B ND
Load
SIL 3
250 Vdc
175 W
- / AC - / AC - / AC - / AC 115 Vac
Coil
NE Relay Coil and NE or ND Load for interrupting up to 4 loads. AC Coil.
SIL 3 function: configurable via external wiring.
39
SAFETY RELAYS SELECTION TABLE
D5290S
10 A
-080 PLC 250 Vac
Output ON
Service NE
PLC
Service
115 Vac 2500 VA
Output ON
Load Load Load
115 Vac
(Not SIL) SIL 3 (Not SIL) 5+.
10 A MODBUS
NE 250 Vdc
Load
SIL 3 300 W
- / AC - / AC 115 Vac
Coil
Normal Operation: NE Relay Coil and NE Load (1-1). AC Coil.
Safe State: Load is disconnected by disconnecting input (0-0).
+ / AC + / AC
D5290S
10 A
-081 PLC 250 Vac
Output ON
Service NE
PLC
Service
110 Vdc 2500 VA
Output ON
Load Load Load
110 Vdc
(Not SIL) SIL 3 (Not SIL)
10 A 5+.
MODBUS
NE
Load
250 Vdc
SIL 3 300 W
- / AC - / AC 110 Vdc
SAFETY RELAYS
Coil
Normal Operation: NE Relay Coil and NE Load (1-1).
Safe State: Load is disconnected by disconnecting input (0-0).
+ / AC + / AC + / AC + / AC
D5290S
5A
-084
250 Vac
PLC
Service PLC Output ON 1250 VA
NE NE Service
Load Output ON 110 Vdc
(Not A Load Load B Load
110 Vdc (Not SIL)
SIL) SIL 3 SIL 3 5+.
ND Service Service 5A MODBUS
Load
SIL 3
A Load
(Not SIL)
Load
(Not SIL)
B ND
Load
SIL 3
250 Vdc
175 W
- / AC - / AC - / AC - / AC 110 Vdc
Coil
NE Relay Coil and NE or ND Load for interrupting up to 4 loads. AC Coil.
SIL 3 function: configurable via external wiring.
+ / AC + / AC
D5290S
10 A
-091 PLC 250 Vac
Output ON
Service NE
PLC
Service
230 Vac 2500 VA
Output ON
Load Load 230 Vac
Load 5+.
(Not SIL) SIL 3 (Not SIL) MODBUS
10 A
NE
Load
250 Vdc
SIL 3 300 W
- / AC - / AC 230 Vac
Coil
Normal Operation: NE Relay Coil and NE Load (1-1). AC Coil.
Safe State: Load is disconnected by disconnecting input (0-0).
40
SAFETY RELAYS SELECTION TABLE
- / AC - / AC 48 Vdc
Coil
Normal Operation: NE Relay Coil and NE Load (1-1).
Safe State: Load is disconnected by disconnecting input (0-0).
+ / AC + / AC
D5291S
10 A
250 Vac
PLC PLC
Output OFF Output ON
2500 VA 5+.
MODBUS
0 Vdc 24 Vdc
10 A
ND ND
Load
Service Load Service Load Load
250 Vdc
SIL3 SIL3 300 W
- / AC - / AC
24 Vdc
Normal Operation: ND or NE Relay Coil and ND Load (0-0 or 1-0). Coil
Safe State: Load is connected by connecting input (1-1) or
SAFETY RELAYS
+ / AC
D5293S 5+.
MODBUS
4A
250 Vac
1000 VA
PLC NE
Output ON Load
24 Vdc SIL 3
4A
250 Vdc
120 W MODBUS
- / AC
24 Vdc
Normal Operation: NE Relay Coil and NE Load (1-1). Coil
Safe State: Load is disconnected by disconnecting input (0-0).
Smart line and load diagnostic functions. Modbus output.
+ / AC + / AC
D5294S
5+.
4A MODBUS
250 Vac
PLC F&G/ND PLC NE
Output OFF Load Output ON Load 1000 VA
0 Vdc SIL 3 24 Vdc SIL 3
4A
250 Vdc
120 W
MODBUS
- / AC - / AC
24 Vdc
Normal Operation: ND Relay Coil and F&G/ND Load (0-0) or
Coil
NE Relay Coil and NE Load (1-1).
Safe State: Load is connected by connecting input (1-1) or
Load is disconnected by disconnecting input (0-0).
Smart line and load diagnostic functions. Modbus output.
41
SAFETY RELAYS SELECTION TABLE
4A
250 Vdc
120 W MODBUS
- / AC - / AC
125 Vdc
120 W
- / AC - / AC
24 Vdc
SAFETY RELAYS
D1092D
PLC PLC PLC PLC
Output A ON Output B ON Output A OFF Output B OFF
24 Vdc 24 Vdc 0 Vdc 0 Vdc
3A
250 Vac
NE Service NE Service ND Service ND Service 750 VA
Load A Load Load B Load Load A Load Load B Load
SIL 3 SIL 3 SIL 3 SIL 3 5+.
MODBUS
3A
125 Vdc
120 W
- / AC - / AC - / AC - / AC
24 Vdc
Normal Operation: Dual channel. NE Relay Coil and NE Load (1-1) or Coil
ND Relay Coil and ND Load (0-0).
Safe State: Load is disconnected by disconnecting input (0-0) or
Load is connected by connecting input (1-1).
+ / AC + / AC
D1092S PLC PLC
-069 Output ON Output ON 3A
24 Vdc 24 Vdc 250 Vac
750 VA
NE Service ND Service
Load Load 5+.
Load Load 3A MODBUS
SIL 3 SIL 3
125 Vdc
120 W
- / AC - / AC
24 Vdc
Normal Operation: NE Relay Coil and NE Load (1-1) or ND Load (1-0). Coil
Safe State: Load is disconnected by disconnecting input (0-0) or
Load is connected by disconnecting input (0-1).
42
SAFETY RELAYS SELECTION TABLE
D1092D
PLC PLC PLC PLC
-069 Output A ON Output B ON Output A ON Output B ON 3A
24 Vdc 24 Vdc 24 Vdc 24 Vdc
250 Vac
NE Service NE
Service
ND
Service
ND
Service
750 VA
Load A Load B Load A Load B
Load Load Load Load
SIL 3 SIL 3 SIL 3 SIL 3 5+.
MODBUS
3A
125 Vdc
120 W
- / AC - / AC - / AC - / AC
24 Vdc
Normal Operation: Dual channel. NE Relay Coil and NE Load (1-1) or
Coil
NE Relay Coil and ND Load (1-0).
Safe State: Load is disconnected by disconnecting input (0-0) or
Load is connected by disconnecting input (0-1).
+ / AC + / AC
D1093S
3A
PLC NE PLC ND
Output ON Load
Service Output OFF Load Service 250 Vac
24 Vdc Load 0 Vdc SIL 3 Load
SIL 3
750 VA
5+.
MODBUS
3A
125 Vdc
- / AC
120 W
- / AC
D5093S
24 to 220 PLC 0
PLC
VAC / VDC Input VAC / VDC
Input
from field from field
50 mA 5+.
MODBUS
35 Vdc
24 to 220 0 50 mA 5+.
PLC PLC MODBUS
VAC / VDC
from field
Input VAC / VDC
from field
Input 35 Vdc
43
44
D1000 SERIES
D1000
SERIES
INTRINSICALLY SAFE ISOLATORS
SUITABLE FOR SIL 2 AND SIL 3 APPLICATIONS
45
D1000
Safe Area Terminal blocks
with engraved identification
CHARACTERISTICS
Terminal Block identification
114.5 mm
22.5 mm
46
D1000 SERIES
FEATURES
General Features High Performance
• More than 30 modules suitable for SIL 3 - SIL 2 • High signal transfer accuracy and repeatability
applications according to IEC61508, IEC61511 • Advanced circuitry provides low heat dissipation,
• Single channel versions available if required, ensuring modules run cool despite their high
to provide single loop integrity on Emergency functionality
Shut Down and Fire & Gas applications • Low power consumption
• Configuration via DIP switch for easy field setup • SMD manufacturing for a long and reliable life
• LED indication for power, signal status and line
fault conditions
• Modules accept DC power supply over a wide
range for 12 or 24 Vdc applications
• 2 modules (D1130 - D1180) can be powered from Wide Functionality
85 to 264 Vac, 50-400 Hz, or from 100 to 350 Vdc
• Wide operating temperature range (-20 / +60°C) • Wide range of Digital and Analog I/Os
• Relay contacts rated for 2 A to directly switch high loads
• Three port galvanic isolation to eliminate noise,
ground loop problems and to provide Intrinsic
Enclosure Characteristics Safety without a high integrity safety earth
connection
• High channel density resulting from innovative • Line fault alarm detects open or short circuit of
circuit design using advanced surface mount field cables
components • Optional Power Bus enclosure
• Single, dual or quad channel models
• Plug-in screw terminal blocks to secure
terminations up to 2.5 mm2
• Plug-in PCB can be removed for configuration
operations
PACKING
High Packing Density
• 35 mm (Top Hat) DIN-Rail
• Ultra slim 4 channels 22.5 mm wide DIN-Rail mounting
modules
• 6 mm per channel
• Up to 176 I/O channels per meter of DIN-Rail
• Power Bus enclosure allows a significant reduction in cables,
costs and space
47
D1000 SERIES
POWER BUS
Enhanced Power Bus Mounting
24 Vdc power supply voltage can be applied to the
module, by connecting the voltage directly to the
plug-in Terminal Block of each module, or via Power
Bus System.
The system consists of a standard Din-Rail Bar and
modules with Bus Connectors (female on one side
and male on the opposite side) of 8 A Capacity. It
is always possible to remove modules, without
Power Bus Connector Power Bus Connector
Male Side Female Side disconnecting the connectors, because modules
are plug-in types. Contacts on the Terminal Block
are omitted to avoid accidental short circuits on the
Power Bus.
TERMINATION BOARD
PBCO Series
G.M. International offers many solutions for Customized
Boards for an easy integration with instrumentation of
manufacturers like Invensys Foxboro, ABB, Triconex,
Yokogawa, Honeywell, HIMA and many more.
New Board models are engineered on customer request
for any system or application: contact us for details.
48
D1000 SERIES
CONFIGURATION
PPC 1090 Pocket Portable Configurator
The PPC1090 is a small and handy Pocket Portable Configurator suitable
to program configuration parameters of D1000 series modules like:
type of input Sensors, input and output Ranges, Burnout conditions,
High/Low Alarm mode, Relay NE/ND, Alarm Trip Point, Hysteresis value
and ON/OFF Alarm delays.
The Configurator is powered by the unit and can be plugged in without
disconnecting the module.
SWC1090 Software
The SWC1090 software is designed to provide
a PC user interface to configure programmable
D1000 modules.
It easily allows the user to:
• Read and write configuration parameters to
the units
• Store and restore data to and from local hard
drive for backup or archive
• Load factory default configurations
• Monitor Input values via USB/COM port
• Print a report sheet containing configuration
parameters and additional information
49
D1000 SELECTION TABLE
4-20 mA
D1010S 0-20 mA 1
(source or sink)
0/4-20 mA or
D1010D 2-Wires Passive Tx 1-5 V 2 24
4-Wires Active Tx 0-5 V Vdc
Smart compatible
1 in
D1010D Two duplicated outputs
2 out
0/4-20 mA 4-20 mA
ANALOG IN
4-20 mA 4-20 mA 24
D1012Q 4 -
2-Wires Passive Tx (source) Vdc
D1014S 4-20 mA 1
4-20 mA
(source or sink) 12-24
2-Wires Passive Tx
or Vdc
Smart compatible
D1014D 1-5 V 2
4-20 mA
D1020S 0-20 mA 1
ANALOG OUT
4-20 mA
Analog Signal to
0-20 mA
I/P Converters, 24
Bus powered
Electrovalves, Vdc
signal from DCS, PLC or
D1020D Actuators and 2
other control devices.
Displays
Smart compatible
D1022S 1 -
FIRE & GAS
DETECTOR
1 to 40 mA Loop
1 to 40 mA
to DCS, PLC or powered
Fire/Smoke Detector
other control devices
D1022D 2 -
50
D1000 SELECTION TABLE
Open Collectors
D1031D Voltage free + OC (alarm or duplicator) 2
Contact, + LED (fault status) 12-24
Proximity Switch Vdc
Line fault detection Open Collectors
D1031Q 4
+ LED (fault status)
DIGITAL IN
Open Collectors
D1033D Voltage free + OC (alarm or duplicator) 2
Contact, + LED (fault status) 24
Proximity Switch
Vdc
Line fault detection 4 Open Collectors
D1033Q Isolated inputs 4
+ LED (fault status)
5+.
D1034S Voltage free 1 MODBUS
Contact,
Transparent repeater
of input status 12-24
Proximity Switch
0 to 8 mA range Vdc
Line fault detection 5+.
D1034D 2 MODBUS
Isolated inputs
0-50 KHz Voltage free
12-24
D1035S Magnetic Pickup SPST optocoupled 1 -
Vdc
or Proximity Switch OC transistor
51
D1000 SELECTION TABLE
Electrovalve, Audible
D1040Q 4
Alarm or other devices
Bus
D1041Q LED Voltage free Contact, 4
Powered
Logic Level,
24
Loop powered 24 Vdc or
Vdc
Electrovalve, Audible from DCS, PLC or
D1042Q other control devices 4 5+.
Alarm or other devices MODBUS
Loop
Electrovalve, Audible Powered
D1043Q 4
Alarm or other devices
DIGITAL OUT
D1044D
from DCS, PLC or
other control devices 2
1oo2
Channels
52
D1000 SELECTION TABLE
Vibration Transducers,
Transparent 24
D1062S Accelerometers, 1 -
input repeater Vdc
2/3-Wires sensors
ISOLATOR CONV.
Transparent
LOAD CELLS
D1063S 1 -
Up to 4, 350 Ω, input repeater.
24
6-Wires Load Cells
mA (source or sink) and Vdc
in parallel.
D1064S V Output and 1
MODBUS RTU
24
D1080D 2 -
Vdc
3-WIRES SENSOR
3-Wires Sensors,
Electro-optic, 110-230
D1180D 2 -
photo-cells Vac
and other devices
Voltage free SPST
15-24
D1081D optocoupled OC 2 -
Vdc
transistor
53
D1000 SELECTION TABLE
mV
Two duplicated outputs
D1072D Adder/Subtractor 1-2
Low/High pass
Separately powered
D1090Q 0 to 50 mV to 4 - -
4-20 mA, 0-20 mA
D2010M, D2011M
0 to 20 mV or
Separately powered
D1094Q 0 to 40 mV to 4 - -
0-5 V, 0-10 V
D2010M, D2011M
SUPPLIES
POWER
for more information and details about Power Supplies, see section at page 75
SAFETY
RELAYS
for more information and details about Safety Relays, see section at page 33
54
D1000 ACCESSORIES
MCHP065 DIN-Rail Anchor for terminal block side of the Power Bus
MOR015 Plug-in terminal block male, vertical out, for Power Bus
MOR017 Plug-in terminal block male, horizontal out, for Power Bus
MOR022 Plug-in terminal block female, horizontal out, for Power Bus
55
EI1000ADP SERIES
G.M. International offers continuity in the service of Elcon Instruments 1000 series
(no longer available from the manufacturer).
Features
• ATEX, FM, FM-C Certifications
• Interchangeability with Elcon 1000 Series modules
• Possibility to replace Elcon modules without modifying
any wiring or connections
• Use of the same Elcon boards
• Identification using the same Elcon part-number
56
EI1000ADP SERIES
57
58
D6000
SERIES
ENHANCED GALVANIC ISOLATORS
SUITABLE FOR SIL 2 APPLICATIONS
59
D6000
CHARACTERISTICS
DIN-Rail lock
60
D6000 SERIES
D6200
DIMENSIONS
General Features
120 mm • Modules suitable for SIL 2 applications
according to IEC61508, IEC61511
• Single or multichannel versions available
• Configuration components are easily accessed
by removing the side cover
• DIP switch configurability for easy field setup
• LED indication for power, signal status and line
fault conditions
• Modules accept DC power supply over a wide
range for 24 Vdc (20-30 Vdc) applications
• Wide operating temp. range: -40 to +60/+70 °C
123 mm
22.5 mm
Terminal Blocks
Terminal Blocks for for connection
Field connections to control room
61
D6000 SERIES
High Performance
• High signal transfer accuracy and repeatability
• Advanced circuitry provides very low heat dissipation,
ensuring modules run cool despite their high density
and functionality
• SMD manufacturing for a long, reliable life
• Complete absence of electrolytic capacitors ensures
minimum 20 years lifetime
Wide Functionality
• Wide range of digital and analog I/O
• Three port galvanic isolation to eliminate noise,
ground loop problems
• Line fault alarm detects open or short circuit of field
cables
• Optional power bus DIN-Rail connector
• Standard Termination Board with custom connectors
for integration into customized Boards
• EMC Compatibility to EN61000-6-2, EN61000-6-4,
EN61326-1, EN61326-3-1 for safety system
62
D6000 SELECTION TABLE
D6011S 1
4-20 mA
4-20 mA 24
2-Wires passive Tx;
(source) Vdc
Smart compatible
D6011D 2
D6014S 1
4-20 mA 4-20 mA
2-3-4 Wires (source or sink)
24
D6014D Active or Passive Tx; 2
Vdc
Smart compatible
Two 1 in
D6014D
ANALOG IN
4-20 mA
D6212Q 4
+ Modbus
63
D6000 SELECTION TABLE
Open Collector
D6031S 1
+ LED (fault status)
Voltage free Contact,
Proximity Switch Open Collectors
1 in 24
D6031D Line fault detection + O.C. (alarm duplicator)
2 out Vdc
Isolated inputs + LED (fault status)
1 Open Collector
D6031D 2
+ LED (fault status)
64
D6000 ACCESSORIES
MOR017 Plug-in terminal block male, horizontal out, for Power Bus
MOR022 Plug-in terminal block female, horizontal out, for Power Bus
65
66
D2000 SERIES
D2000
SERIES
INTRINSICALLY SAFE MULTIPLEXER
FOR ANALOG AND DIGITAL INPUTS FROM ZONE 0
67
D2000
CHARACTERISTICS
Features
• High density, up to 256 Analog Inputs (TC, RTD, mV) and
up to 128 digital inputs (contact / proximity) in the same
system (expandable up to 7936 inputs)
• High accuracy 18 bit A/D converter
• Robust Isolation (± 200 V test voltage channel to channel),
provides high immunity against interference and ground loops
• Intrinsically safe for installation in Zone 1 or 2
• Field units can be placed up to 4 km from Gateway
• Redundant communication lines
• Programmable via PC (RS232) and Modbus (RS485)
• Repeats input contacts via Relay or Transistor outputs
• Reduces field wiring and installation costs
• Eliminates the need of PLC - DCS I/O cards
• Field unit operating temperature: - 40 to + 60 °C
• AISI 316 stainless steel enclosures are available for field
units (Series GM2300)
• Gateway D2050M can be installed in Zone 1 / Div. 1 by
using an explosion proof enclosure
68
D2000 SERIES
D2050M
Gateway/Power Supply Multiplexer Unit
• II (1) G [Ex ia Ga] IIC
• Supply 24 Vdc
• Redundant MODBUS RTU - RS485 lines up to 115200 bauds
• RS-232 line for configuration via PC
• Suitable to drive contact/proximity output repeaters
• Safe Area Installation or Zone 1 / Div 1 when mounted in an D2010M
D2030M
explosion proof housing
• Operating Temperature - 20 to + 60 °C.
D2010M - D2011M
Analog/Temperature Multiplexer Unit
• II (1) 2G Ex ia [ia Ga] IIC T4 Gb
• 16 Channels per Unit, each for 2-3-4 wires RTD, Pt100, Pt50,
Ni100, Cu100, Cu53, Cu50, Cu46,
TC Type A1, A2, A3, B, E, J, K, L, Lr, N, R, S, T, U.
• Up to 16 Units per gateway
• 256 Channels are scanned in 1700 ms
• Redundant Communication with D2050M gateway
• PC Programmable via SWC2090 software
• Zone 1 / Div. 1 Installation
• Operating Temperature - 40 to + 60 °C
D2030M
Switch/Proximity Multiplexer Unit
• II (1) 2G Ex ia [ia Ga] IIC T4 Gb
• 32 Channels per Unit
• Input from Contact-Proximity Sensors
• Up to 4 Units per System
• 128 Channels are scanned in 50 ms
• Redundant Communication with D2050M Gateway
• PC Programmable via SWC2090 software
• Zone 1 / Div. 1 Installation
• Operating Temperature - 40 to + 60 °C
D2052M - D2053M
Contact/Proximity Output Repeater
• 32 Isolated Channels with SPDT Relay contacts (D2052M)
or Open Collector Transistors (D2053M)
• up to 4 Units per gateway
• 128 Channels are scanned in 50 ms
• Safe Area Installation or Zone 1 / Div. 1 when mounted in an
explosion proof housing
• Operating Temperature - 20 to + 60 °C
69
D2000 SERIES
SYSTEM
ARCHITECTURE
D2000 Multiplexer accepts both analog and
digital inputs in the same system allowing the user
to choose whatever configuration fits his application
best in terms of cost and cabling.
The following are two examples of achievable
system architectures.
70
D2000 SERIES
MULTIPLEXING TECHNIQUE
Signal data acquisition Multiplexing in hazardous area
In industrial processes it is a common need to acquire For applications in classified Hazardous Areas each
a relevant number of temperatures, pressures, signal must be protected from the risk of causing
flows, levels and other process variables as well as an ignition of flammable mixtures: this requires a
the status of switches or proximitors and to collect safety barrier for each input channel. By using an
all these data in a single remo te collection area Intrinsically Safe multiplexer solution, protection
(i.e. in a control room) where PLC (Programmable must be applied only to the communication lines,
Logic Controller) or a Process Computer collects decreasing complexity, maintenance and costs.
all data for monitoring purposes and availability
to operators. SCADA (Signal Conditioning And
Data Acquisition) equipments are particularly
suited for this purpose. Typical applications are When multiplexing is the only solution
Furnaces, Cracking Towers, Gasifiers, Reactors,
Distillers, Separators, Oxidizers, Tank Monitoring, In case of revamping or expansion in the plant,
Flare Stacks. Mux system permit fast, accurate and the space for adding cables may be limited or
stable Analog to Digital conversion, high speed the few existing spare cables may be the only ones
computing, sophisticated intelligence and powerful that can be used.
measuring capabilities. All this performance can Radio Frequency links, beside costs and licensing
be packed into compact, reliable units that can problems, suffer data security and reliability issues.
operate in harsh environments. Multiplexing often becomes the only practical
Multiplexers are a typical SCADA multi channel solution.
equipment that can be located in the field close
to the process area where the input channels can
be connected with shorter lines. All input channel
signals are converted in a numeric form and
transmitted to a remote location via a single or
redundant communication line.
71
D2000 SELECTION TABLE
Field Ch.
Model Hazardous Area Safe Area Supply
device per unit
Universal TC,
D2010M 16
3/4-Wires RTD, mV
D2050M Gateway
Universal TC, via redundant Supplied
INTRINSICALLY SAFE MULTIPLEXER
72
D2000 ACCESSORIES
CABF005
Flat cable to interconnect D2010M with expander units D2011M.
CABF006
Available in 15, 30, 50 cm lengths.
CABF007
CABF022
Flat cable to interconnect D2050M with repeater units D2052M/D2053M.
CABF023
Available in 15, 30, 50 cm lengths.
CABF024
73
74
POWER
SUPPLIES
INTRINSICALLY SAFE AND
NON-INCENDIVE POWER SUPPLIES
75
POWER SUPPLIES
MODELS
PSD1000
Universal Input Power Supply for D1000 Series Isolators (PS)
• Supply 90 - 265 Vac
• Output 24 Vdc, 500 mA
• 2 Units can be paralleled for redundancy or additional power
• Remote indication for Power Failure for PSD1000F
• Installation adjacent to D1000 Series Modules, without Safety distance
of 50 mm, because Supply and Output Terminal Blocks are on the same side
• Zone 2 / Div. 2 installation
PSD1001
SIL 2 / SIL 3 4 Channels Intrinsically Safe Power Supply (PS)
• Supply 24 Vdc
• 4 Independent Outputs 15 V, 20 mA
• Output to Zone 0 / Div. 1
• Zone 2 / Div. 2 installation
• Flexible modular multiple output capability
• Output short circuit proof and current limited
• High Reliability, SMD components
• High Density, four channels per unit
• Simplified installation using standard DIN Rail and plug-in terminal blocks
PSD1001C
SIL 2 / SIL 3 1 Channel Intrinsically Safe Power Supply (PS)
• Supply 24 Vdc
• Output 13.5 V - 100 mA
• Input from Zone 0 / Div. 1
• Zone 2 / Div. 2 installation
• Output short circuit proof and current limited
PSD5201
SIL 3 1 Channel Intrinsically Safe Power Supply (PS)
• Supply 24 Vdc
• 1 Output 14.5 V - 150 mA
• Output to Zone 0 / Div. 1
• Zone 2 / Div. 2 installation
76
POWER SUPPLIES
PSW1250
SIL 3 Universal Input Power Supply
24 Vdc, 50 A, Zone 2 / Div. 2 Installation Suitable for Parallel Operations
• Supply 100 - 264 Vac
• Power Factor correction
• Output 24 Vdc, 50 A; regulated and adjustable from 21 to 28 Vdc.
• Efficency better than 89% at 230 Vac supply
• Two or more Units can be paralleled for Redundancy or additional power with
automatic load sharing
• Two Units in parallel offer AC1 or AC2 redundancy
• Remote indication for Power Failure
• Zone 2 / Div. 2 installation
• ATEX: II 3G Ex nA nC IIC T4 Gc
• IECEx: Ex nA nC IIC T4 Gc
• Three over-voltage redundant protections
• Mosfet Active Ideal Diode instead of Schottky diode reduces power dissipation
• High load fuse breaking capability without interrupting operations
• Wall mounting
• Stainless steel AISI 304 enclosure
77
POWER SUPPLIES
PSS1250
SIL 3 Power Supply System Universal Input,
24 Vdc, 50-100-150 A, Zone 2 / DIV. 2 Installation
The Power Supply System type PSS1250 is an anodized aluminum 19”, 9” or 7” Rack unit (4U high) suitable
to accept up to six (for 19” rack) or two (for 9”/7” rack) plug-in Power Supply Modules type PSM1250.
PSO1250 Overview module for diagnostic functions is available on 19” and 9” racks.
Features
• Supply 100 - 264 Vac
• Power factor correction
• Output 24 Vdc, 50 A per module
• Regulated and adjustable output voltage from 21 to 28 Vdc
• Efficiency better than 89% at 230 Vac supply
• Two or more Units can be paralleled for Redundancy
or additional power with automatic load sharing
• Input and Ouput redundance
• Remote indication for fault or Power Failure
• Zone 2 / Div. 2 installation
• ATEX: II 3G Ex nA nC IIC T4 Gc
• IECEx: Ex nA nC IIC T4 Gc
7” Rack Enclosure
• Hot swappable modules (certified for Zone 2) available (HS option)
• Three over voltage redundant protections
• Mosfet Active Ideal Diode instead of Schottky diode
reduces power dissipation
• High load fuse breaking capability without interrupting operations
• Wall mounting
Ordering options
• 19”, 9” or 7” Rack enclosure
• Hot Swapping (HS) capability
• PSO1250 Diagnostic Module (19” or 9”)
• Multiple Output configurations (see data sheet)
9” Rack Enclosure
78
POWER SUPPLIES
CONFIGURATION EXAMPLES
PSS1250-HS-7-3-D
Two AC supplies, three redundant 50 A Outputs, PSO1250 overview module
Six modules connected in parallel in groups of two.
PSS1250-HS-7-2-D
Two AC supplies, one redundant 100 A + one redundant 50 A Outputs, PSO1250 overview module
One group of four modules and one of two modules.
DC1 DC2
79
POWER SUPPLIES
PSS1250-HS-7-1-D
Two AC supplies, one redundant 150 A Output, PSO1250 overview module
Six modules connected in parallel.
DC1
PSS1250-HS-3-D
Two AC supplies, one redundant 50 A Output, PSO1250 overview module
Two modules connected in parallel.
DC1
PSS1250-HS-2
Two AC supplies, one redundant 50 A Output
Two modules connected in parallel.
DC1 DC2
80
SELECTION TABLE
Ch. SIL
Model Hazardous Area Output Supply
per unit level
24 V, 500 mA to power
PSD1000 Zone 2 / Div. 2 1 95-264 Vac -
D1000 Series Modules
24 Vdc MODBUS
PSD1001C Zone 0 / Div. 1 100 mA at 13.5 V 1
5+.
PSD5201 Zone 0 / Div. 1 14.5 V, 150 mA 1 24 Vdc MODBUS
5+.
PSW1250 Zone 2 / Div. 2 24 V, 50 A 1 100-264 Vac MODBUS
24 V, 50-100-150 A 5+.
PSS1250 Zone 2 / Div. 2 up to 6 100-264 Vac MODBUS
Redundant
81
82
T3010 SERIES
D9000
SERIES
SURGE PROTECTORS
83
D9000
CHARACTERISTICS
D9000 series provides surge protection for all kinds of applications in different
industries such as Oil&Gas, Petrochemical, Steel etc. avoiding signal interruption and
protecting control room equipment.
D9024S
Modular Terminal Block DIN Rail surge protector
D9024S modules provide two-stage surge protection
for floating I/ 0 signals of measurement and control and
safety systems. Its depth of 6mm allows for easy fitting
into any marshalling or distribution cabinet.
With disconnect knife on both signal paths features for
easy testing of the loop.
D9024S
Features
• SIL 3 according to IEC 61508:2010 Ed.2
• Input from Zone 0 (Zone 20), installation in Zone 1 and 2
• Disconnection of signal circuit by disconnect knife
• Protection of a floating double wire in intrinsically
safe circuits
• High Density, 6.2 mm per channel
• HART compatible
• Covers available to terminate a row of D9024S
84
D9000 SERIES
a
b
a
2 4
IN OUT
b
1 3
D9024S
D9324S
½ inch NPT connection screw-on surge protector
D9324S provides surge protection for floating I/ 0
signal circuit in screw-on module with IP67 protection
for sensor heads, connection ½ inch 14 NPT
Its capability to be installed on explosion proof
enclosures guarantees suitability also for a wider range
of applications
D9324S
Features
• SIL 3 according to IEC 61508:2010 Ed.2
• Input from Zone 0 (Zone 20), installation in Zone 1 and 2
• Protection of a floating double wire in intrinsically
safe circuits
• Suitable for explosion proof enclosures
• HART compatible
Blue and brown: Floating circuit lines
Black: Earth connection
85
T3010 SERIES
T3000
SERIES
4 ½ DIGIT LOOP INDICATOR
INSTALLATION IN ZONE 0
87
4 ½ Digit Loop Powered Indicator
Mounting options
Figure B
88
IMMAGINE
89
GMINTSRL.COM
ONLINE INFORMATION
A wide range of services and information can be found online at www.gmintsrl.com
Download Products
• Data Sheets • Guided model finder
• Instruction Manuals • Series presentation
• Application Notes • Model details
• Certificates • Advanced search
• Software
Contacts
News • Agents and Distributors
• Latest products • Quotation request form
• New Certifications • Technical and Commercial contacts
• Worldwide Exhibitions
Utilities
• Online tools for webmasters
• Mailing List
• I.S. Loop verification tool
• Product finder
90
Data specified in this document are merely descriptive of the products and should be integrated with relevant technical specifications. Our
products are constantly being further developed and the information presented herein refers to the latest's product release. No statements
concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. Terms & Conditions can be found at www.gmintsrl.com.
G.M. International s.r.l.
Via G. Mameli, 53-55
20852 Villasanta (MB)
ITALY
www.gmintsrl.com
[email protected]