Data Sheet - TNTplus

The Hach® TNTplus Vial Chemistry system simplifies water analysis by using unique barcode labels for automatic method identification, reducing errors and eliminating the need for reagent blanks. The vials feature innovative Dosicaps for safe handling and come with documented shelf life and calibration data to ensure accurate results. A variety of tests are available for parameters such as alkalinity, ammonia, and phosphorus, with detailed method instructions provided for ease of use.

Uploaded by

Denny
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
15 views4 pages

Data Sheet - TNTplus

The Hach® TNTplus Vial Chemistry system simplifies water analysis by using unique barcode labels for automatic method identification, reducing errors and eliminating the need for reagent blanks. The vials feature innovative Dosicaps for safe handling and come with documented shelf life and calibration data to ensure accurate results. A variety of tests are available for parameters such as alkalinity, ammonia, and phosphorus, with detailed method instructions provided for ease of use.

Uploaded by

Denny
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Applications

• Wastewater
• Industrial

TNTplus® Vial • Drinking Water

Chemistries

Expert water analysis made simple.


Reduce errors No reagent blank necessary
A unique barcode label on each Hach® TNTplus Vial Chemistry The high quality of TNTplus vials, tight reagent production
is automatically read by the spectrophotometer when used controls, instrument calibration verification, and high
with Hach’s DR6000™ UV-VIS Spectrophotometer or DR3900™ instrument stability all combine to eliminate the need to run
Benchtop Spectrophotometer to identify the appropriate reagent blanks —saving you time and money!
method and take the measurement. This significantly reduces
errors as well as scratched, flawed or dirty glassware becomes Safe and easy handling
non-issue as the instrument averages 10 readings and rejects TNTplus vials use innovative Dosicaps that are easier to use than
outliers. powder pillows or liquid reagents. There’s no risk of spillage,
no safety risk, or risk of contamination with Dosicaps because
Lot after Lot - Be Right the reagents are completely contained within the vial cap. The
Truecal™ with each vial includes the calibration data for each glassware used assures the best precision and the vials have a
individual lot, reducing variation in results. This allows you to flat bottom so they can stand on their own.
meet reporting standards and to perform proficiency testing
Packages of TNTplus vials are color-coded for fast and easy
with higher confidence.
parameter and range recognition for the exact test you need.
Documented shelf life and COA Step-by-step illustrated test methods are printed on the box for
quick reference.
The barcode details batch number and expiry date of reagents,
which are documented along with the measurement result.
An automatic warning is issued if expiry date has passed.
Certificate of Analysis (COA) is available on RFID* tag on
the box, which can be read out with the DR6000 or DR3900
spectrophotometer.

*RFID technology currently available in US, Canada, Puerto Rico, Australia, New Zealand, and Colombia only.
2 TNTplus® Vial Chemistries

TNTplus Vial Tests*


Prod. No. Parameter Range Method Name Method Truecal EPA
TNT870 Alkalinity, Total 25 - 400 mg/L CaCO3 Colorimetric 10239
TNT848 Aluminium 0.02 - 0.50 mg/L Al Chromazurol S 10215
TNT830 0.015 - 2.00 mg/L NH3-N Salicylate 10205 Yes Yes
TNT829 0.50 - 5.00 mg/L NH3-N Salicylate 10205 Yes
TNT831 1 - 12 mg/L NH3-N Salicylate 10205 Yes Yes
TNT832 Ammonia, Nitrogen 2 - 47 mg/L NH3-N Salicylate 10205 Yes Yes
TNT837 10 - 100 mg/L NH3-N Salicylate 10205 Yes
TNT833 47 - 130 mg/L NH3-N Salicylate 10205 Yes Yes
TNT834 100 - 1800 mg/L NH3-N Salicylate 10301 Yes
TNT882KTO Anammox Activity 0 - 1000 mAbs Heme 10304
TNT817 International Bitter Units ≥2 International Bitter Units Analogous MEBAK and ASBC 10288
TNT877 Boron 0.05 - 2.50 mg/L B Azomethine-H 10274
TNT852 Cadmium 0.02 - 0.30 mg/L Cd Cadion 10217
1 - 70 mg/L Cl
TNT879 Chloride Iron(III)-thiocyanate 10291
70 - 1000 mg/L Cl
TNT866 Chlorine, Free 0.05 - 2.00 mg/L Cl2 DPD 10231 Yes
10231,
TNT867 Chlorine, Total 0.05 - 2.00 mg/L Cl2 DPD Yes
10232
Chromium, Hexavalent
TNT854 0.03 - 1.00 mg/L Cr 1,5-Diphenylcarbohydrazide 10218 (Cr6+) Yes
Chromium, Total
TNT820 1 - 60 mg/L COD Reactor Digestion 10211 Yes
TNT821 3 - 150 mg/L COD Reactor Digestion 8000 Yes Yes
TNT822 COD (Chemical Oxygen Demand) 20 - 1500 mg/L COD Reactor Digestion 8000 Yes Yes
TNT823 250 - 15000 mg/L COD Reactor Digestion 10212 Yes
TNT824 5,000 - 60,000 mg/L Reactor Digestion 10212 Yes
TNT815 COD (for samples up to 7 - 70 mg/L COD Reactor Digestion 10299
TNT816 20000 mg/L Chloride) 70 - 1000 mg/L COD Reactor Digestion 10299
Chemical Oxygen Demand
TNT825 25 - 1000 mg/L COD Reactor Digestion 8000
(COD), Mercury-Free
TNT860 Copper 0.1 - 8.0 mg/L Cu Bathocuproin 10238
TNT862 Cyanide 0.01 - 0.6 mg/L CN Pyridine barbituric acid 10265 Yes
TNT878 Fluoride 0.1 - 2.5 mg/L F SPADNS 2 10225 Yes
TNT871 Formaldehyde 0.5 - 10 mg/L H2CO Acetylacetone 10295
Iron, Ferrous
TNT858 0.2 - 6.0 mg/L Fe 1, 10 Phenanthroline 10229 Yes
Iron, Total
TNT850 Lead 0.1 - 2.0 mg/L Pb PAR 10216
TNT849 Magnesium 0.5 - 50 mg/L Mg Metalphthalein 10292
TNT856 Nickel 0.1 - 6.0 mg/L Ni Dimethylglyoxime 10220
TNT835 0.23 - 13.50 mg/L NO3-N Dimethylphenol 10206 Yes Yes
TNT836 Nitrate, Nitrogen 5 - 35 mg/L NO3-N Dimethylphenol 10206 Yes Yes
TNT838 15 - 150 mg/L NO3-N Dimethylphenol 10206 Yes
TNT839 0.015 - 0.600 mg/L NO2-N Diazotization 10207 Yes Yes
TNT840 Nitrite, Nitrogen 0.6 - 6.0 mg/L NO2-N Diazotization 10237 Yes Yes
TNT841 2 - 90 mg/L NO2-N Diazotization 10296
Nitrogen,
TNT880 0 - 16 mg/L N Simplified TKN (s-TKN™) 10242 Yes Yes
Simplified Total Kjeldahl
TNT826 1 - 16 mg/L N Persulfate Digestion 10208 Yes
TNT827 5 - 40 mg/L N Persulfate Digestion 10208 Yes
Nitrogen, Total
TNT828 20 - 100 mg/L N Persulfate Digestion 10208 Yes
TNT818 100 - 250 mg/L N Persulfate Digestion 10208 Yes
TNT868 Phenols 5 - 150 mg/L 4-Aminoantipyrine 10266 Yes
3

TNTplus Vial Tests*


Prod. No. Parameter Range Method Name Method Truecal EPA
1.6 - 30 mg/L PO4-P;
TNT846 Phosphorus, Reactive (Ortho) Molybdovanadate 10214
5 - 90 mg/L PO4
0.05 - 1.5 mg/L PO4-P; 0.15 -
TNT843 Ascorbic Acid 10209 Yes Yes
4.5 mg/L PO4
Phosphorus, Acid Hydrolyzable
0.5 - 5.0 mg/L PO4-P (1.5 -
TNT844 Phosphorus, Reactive (Ortho) Ascorbic Acid 10209 Yes Yes
15.0 mg/L PO4)
Phosphorus, Total
2 - 20 mg/L PO4-P; 6 - 60
TNT845 Ascorbic Acid 10209 Yes Yes
mg/L PO4
TNT864 Sulfate 40 - 150 mg/L SO4 Turbidimetric 10227
TNT865 Sulfate 150 - 900 mg/L SO4 Turbidimetric 10227
Dimethyl-p-
TNT861 Sulfide 0.1 - 2.0 mg/L S²- 10294 Yes
phenylenediamine
TNT874 Surfactants, Anionic 0.1 - 4.0 mg/L Methylene Blue (MBA) 10278
TNT885 Surfactants, Cationic 0.2 - 2 mg/L as CTAB Bromophenol Blue 10305
TNT875 Surfactants, Nonionic 0.2 - 6.0 mg/L as Triton x 100 TBPE 10275
TNT876 Surfactants, Nonionic 6 - 200 mg/L as Triton X-100 TBPE 10275
TNT810 1.5 - 30.0 mg/L C Direct Method 10267 Yes
TOC (Total Organic Carbon)
TNT811 30 - 300 mg/L C Direct Method 10267 Yes
TNT819 Vicinal diketones (VDK) 0.015 - 0.5 mg/kg Diacetyl Analogous MEBAK and ASBC 10276
TNT872 Volatile Acids 50 - 2,500 mg/L Acetic Acid Esterification 10240 Yes
20 - 350 mg/L as CaCO3
TNT869 Water Hardness 5 - 100 mg/L Ca Metalphthalein 10293
3 - 50 mg/L Mg
*Subject to change without notice.
Part numbers may vary by country.

Order Information
Accessories
TNT890 Metals Prep Set (used for Cu, Fe, Pb, Cd, & Ni digestion), 50 digestions
TNT892 Calcium Separation Set (for Cadmium TNTplus Test TNT852), 24 separations
TNT919 Sample Blank Vials for TNTplus, 5/pk
BBP078 Pipet, Variable Volume, 0.1-1.0 mL
BBP065 Pipet, Variable Volume, 1.0-5.0 mL
BBP079 Pipet Tips for 0.1-1.0 mL Pipet (BBP078), 100/pk
BBP068 Pipet Tips for 1.0-5.0 mL Pipet (BBP065), 75/pk
LZP320 Pipet Set BBP065 & BBP078, with tips
DRB200 Reactors
DRB200-01 9 vials x 13 mm + 2 vials x 20 mm (single block), 115 VAC
DRB200-02 21 vials x 13 mm + 4 vials x 20 mm (dual block), 115 VAC
DRB200-03 15 vials x 13 mm + 4 vials x 13 mm (dual block), 115 VAC
DRB200-04 12 vials x 13 mm + 8 vials x 20 mm (dual block), 115 VAC
DRB200-05 9 vials x 13 mm + 2 vials x 20 mm (single block), 230 VAC
DRB200-06 21 vials x 13 mm + 4 vials x 20 mm (dual block), 230 VAC
DRB200-07 15 vials x 13 mm + 15 vials x 13 mm (dual block), 230 VAC
DRB200-08 12 vials x 13 mm + 8 vials x 20 mm (dual block), 230 VAC
DRB200 Reactor Adapters
2895805 Reactor Adapter, 16 mm to 13 mm, for TNTplus vials, 5/pk
HHA155 Reducing Adapter for DRB200, 20 mm to 16 mm (for 20 mm vial wells of existing reactors to adapt to 16 mm vials)
4 TNTplus® Vial Chemistries

To complete your chemical analysis, choose from the following Spectrophotometers…*


DR6000 UV-VIS Benchtop Spectrophotometer
With high speed wavelength scanning across the UV and Visible Spectrum, and over 250 pre-programmed testing methods, the
DR6000™ is the industry’s most advanced lab spectrophotometer. Add in guided step-by-step procedures and integrated quality
assurance software, and it makes sure you are ready to handle your comprehensive water testing needs. Available RFID* technology
to read out certificates of analysis (COA) of each TNTplus method. Sample bottles with smart tags can be tracked easily with the
optional Hach RFID sample-ID system.

DR3900 Benchtop Spectrophotometer


Built with the future of water analysis in mind, the DR3900 Spectrophotometer gives consistently accurate results in a simpler
testing format. Using the latest technology, the instrument requires less training and increases confidence in your test results.
With 1 Ethernet and 3 USB ports, the DR3900 easily connects to a computer and is programmed to interface with any LIMS system.
Available RFID* technology to read out certificates of analysis (COA) of each TNTplus method. Sample bottles with smart tags can be
tracked easily with the optional Hach RFID sample-ID system.

DR1900 Portable Spectrophotometer


The DR1900 excels in the field because it is the lightest and most compact portable spectrophotometer. It is built for rugged
conditions, and it’s flexible, accepting the widest range of vial sizes. Built with field use in mind, the DR1900 has a large, clear
screen and a simple user interface that makes testing easier than ever in even the most demanding conditions. Underneath the
rugged exterior, the DR1900 has the largest number,- over 220- of the most commonly tested preprogrammed methods already
built in. You can also use the easy-to-use interface to create your own methods. Tests are performed with a wavelength range of
340 to 800 nm which make this a field instrument you can use to find results typically only seen in laboratory instruments.
TNTplus vial test evaluation possible, but without barcode identification.

*RFID technology currently available in US, Canada, Puerto Rico, Australia, New Zealand, and Colombia only.

World Headquarters: Loveland, Colorado USA | hach.com


United States 800-227-4224 fax: 970-669-2932 email: [email protected]
Outside United States 970-669-3050 fax: 970-461-3939 email: [email protected]
©Hach Company, 2023. All rights reserved.
In the interest of improving and updating its equipment, Hach Company reserves the right to alter specifications to equipment at any time. DOC052.53.25018.Mar23

You might also like