TM-44
TM-44
Flow Meter
Working pressure manufacturing according to
PED 97/23/CE (Lloyd’s Register Certificate Nº 031)
Applications
The standard TM44 turbine flow meter is resistant to
most severe process fluids including acids, alkali,
solvents, water, CIP fluids, oil, minerals, petrochemical
products, cryogenic liquids, and other liquids.
TM44 Turbine flow Meter
Output
Signal
Operation
Free turning rotor (propeller) is contained within a tube. A
liquid flowing through the cylinder will apply a force to the
blade of the rotor causing it to rotate at a speed proportional
to the velocity of the fluid. The proportional relationship
applies over a wide range of flow and viscosity.
The TM44 can be supplied as a basic sensor with a pulse 15 0.3 10 3000 92
output or a 4-20mA output. Alternatively, a number of 20 0.6 182 6000 1070
electronic units are available to provide batch control, 25 0.9 260 13.5 2600
totalisation and a display of instantaneous flow rate. 40 1.9 36 27 400
50 5 270 50 1360
The TM44 is factory tested and supplied with a calibration 65 9 680 90 4800
certificate identifying the precise volume per pulse for the 80 15 760 150 6200
individual flow meter. 100 28 760 184 4600
150 65 800 250 2800
Nº Part name Materials Output Signal mV/pulse (without amplifier), as a function of flow.
Technical Data
• Connections: • Electrical Connection:
- Standard: EN 1092-1 Flanges DN10 to DN500 PN16 - Standard: Hermetically sealed IP65
- On Request: Up to PN-200, ASA Flanges, BSP, NPT,etc. - On request: Explosion Proof enclosure
• Pressure: Standard PN40...PN16 depending on • Recommended cable:
size, on request up to 3000 bar - Shielded, twisted pair, until 30 m
• Temperature: Standard from -50oC to +130oC, - Up to 100 m using the APTM44 amplifier
on request from -100oC to +250oC - Up to 3000 m, using the converter Hz/mA series CI-420
• Accuracy: +0.5%
• Repeatability: +0.05% to 0.1% Hazardous Zone
• Rangeability: 10:1 Explosion Proof enclosures are available for the electronic
• Response: 10 ms units MC01, MT02 which enable visual and operator acces to
• Output Signal: 10...6200mV for flow min-max Cenelec EEx d IIC T6.
• Materials: Body in EN 1.4404 (SS 316L)
Propeller in EN 1.4416 (SS 430)
2
Installation Density and Viscosity
Horizontal or Vertical up to DN80/DN100. For larger sizes, The standard operating ranges of the TM44 are based on
only horizontal installation is recommended. water with a density of 1kg/L and viscosity of 1mPas. With the
supply of each flow meter a calibration certificate is provided
In accordance with the standard API 2534, its necessary to which accurately specifies the output pulses/litre for the
provide a straight pipe section of 10 pipe diameters before specific flow meter.
the turbine and 5 pipe diameters downstream.
Variations in viscosity will alter the number of pulse/litre but it
For the best performance from the TM44, a filter before the will not affect the repeatability of the measurement for the
flow meter is recommended. A mesh size of 1mm2 is required same liquid. The errors associated with variations in viscosity
for sizes up to DN80/DN100 and 3mm2 for DN125 and greater. are shown in Figure 2.
In all the liquid applications that may contain entrained air or Variation in the fluid density and/or viscosity will affect the
gases, a de-gassing chamber is recommended prior to the pressure drop across the flow meter in accordance with
flow meter. This will ensure an accurate measurement of fllow Figure 3.
or volume is always obtained.
To avoid cavitation inside the chamber of the turbine meter, it In general, variations in viscosity or density will only affect the
is recommended that the API standard is followed. That is, “low flow” reading in the TM44. Liquids with a density less
the output pressure of the turbine should always exceed than 1kg/I have a higher minimum flow and liquids with a
double the pressure drop of the measurement and more than density greater than 1kg/I will have a lower minimum flow.
1.25 times the vapour pressure of the liquid or its most
volatile component. Generally, the effect of density is insignificant. Any liquid
density would not alter the scale, based on water, more than
Important: Low voltage signals are used between the TM44 5-7% of the calibration range.
and its electronic unit. The cable must be kept clear of any
power cables or other cables that may cause interference
with the signal.
Typical Installation
Air separator
To the electronics
Flow straightener
Turbine Valve
≥ 5 dn
Filter
≥ 10 dn ≥ 5 dn
3
Turbines TM44
Flows vs Pressure Drop, for water % Errors vs Flow (liquid 1 kg/l, 1 mPa.s) Figure 1
∆p (mm Water)
100 1.000 10.000
10.000 m3 10.000 m3
100.000 l/min.
0
-50
DN
0
-40
DN 0
-30
1.000 m3 DN 1.000 m3
- 2 50
10.000 l/min. DN
0
-20
DN
0
-15
% Flow
DN 25
- 1
DN
100 m3 100 100 m3
DN-
1.000 l/min.
-80
DN
-65
DN
m3/h water
m3/h water
l/min. water
-50
DN
Viscosity Effect, for Liquids Figure 2
10 m3 10 m3
-40
100 l/min. DN
-25
DN
20
DN-
15
DN-
1 m3 1 m3
10 l/min.
-10
DN
∆p (mm Water)
4
Dimensions & Weights. Flanges according to EN 1092-1
lxnº
DN
HAD
D
g
k
L
Flow Rates
DN Flow (m3/hr) Flow Limit Pulses/l ∆p (mm Water)
5
MC-01/MT-02 series Electronic Control Units They are fully user programmable and will adapt directly to
The MC-01 and MT-02 series, are panel mounting micro- anyTM-44 turbine, COVOL, TTL output, or equivalent pulse
processor based control instruments for batching control. generating output trasducers.
MC-01 MT-02
Applications Applications
• Automated process control in any industry with flow rate • Automated process control in any industry with batching
or volume control
Benefits
• Direct interface to Turbines, Covol etc. Benefits
• Direct interface for analog inputs • Very easy to use
• Fully programmable by user • Bright LED display, 7 digit data, 1 digit mode
• Battery back-up stores all data on power failure • Direct interface to Turbines, Covol etc.
• Flow rate readout in I/h and m3/h • Fully programmable by user
• Adaptive filter gives stable flow rate readings • Battery back-up stores all data on power failure
• Volume totalizing counter • Volume totalizing counter
• Volume partial counter • Volume partial counter
• Batching relay • Batching relay
• 16 character x 2 line LCD alpha-numeric display • Remote start push button for batching
• Optional remote start push button for batching • Standard DIN 96 x 96 panel mounting
• Analog output for process control 0...4-20 mA, 0-10V • Plug in connections with screw terminals for easy
• Standard DIN 96 x 96 panel mounting installation and maintenance
• Plug in connections with screw terminals for easy
• Dual relay version for fast aproximation and slow finish
(two control valves)
installation and maintenance
• Optional IP-65 front protection
• Centesimal version for small flowmeters
• Power supply: 110, 220-240, 24 V ac 50-60 Hz
• Optional interface with 12 and 5 volt proximity detectors
12 (not with analog output), 24 Vdc • Power supply: 110, 220-240, 24 V ac 50-60 Hz
• Power consumption: < 3 VA 24 Vdc
• Input signal TM-44: 20 mV... 3 V ac, 0....2000 Hz
• Input signal COVOL: Reed contact, 0....100 Hz
• Input signal Analog: 0-20 mA, 4-20 mA,0-5 V dc,
0-10 V dc, 1-5 V dc, 2-10 V dc
• Remote batch start: By means of a push button
• Precision: 0.01% (0.4% analog input)
• Temperature range: -10oC.......60oC
• Analog output: 12 bit resolution
• Relay: 1 A, 250 V ac, 60 VA
MT-02
Dimensions
33*
96
92
96
96
92
15 156 8
171
6
CIP, CIP II Compact mounted TM44 volume TM44 with CIP, CIP II & CH420L
counter
Compact system featuring:
• TM44 turbine body and electronic counter mounted
together to form a compact unit
• Same flow rates, pressures and other working
conditions as for TM44 series
• CIP electronic counter mounted in IP65 housing with an
injected aluminium base and U.V. treated polycarbonate
cover
• Programmable pulses/unit factor
• Button battery power supply lasts for 30.000 hours
(3-4 years)
• CIP: 7 digit, 9 mm digit size
• CIP II: 7 digit, 8 mm digit size for totalizer counter
5 digit, 6 mm digit size for partial counter
• Counter reset by means of internal push button or 4
external magnet (CIP II totalizer counter cannot be reset)
DN H
DN10 145
DN15 150
DN20 152
H
DN25 155
DN40 162
DN50 167
DN65 175
DN80 182
DN
DN100 192
DN125 205
DN150 217
DN200 242
Dimensions
CIP, CIP II & CH420L CH420R
113 107 (102) (38)
86
22
84
(93)
55
130 92,5
(43)
7
Flow Transmitters and Volume Counter
CH420L CH420R
Characteristics
• HART protocol communications • Power supply from two wire current loop
• Connects directly to a COVOL or TM-44 turbine • Working voltage: 7,5...36 Vdc
• CH420L for compact mounting (local) • Current consumption: less or equal to 20 mA
• CH420R for DIN rail mounting (DIN 46277) • Totalizer: 7digits, 8 mm high
• Programmable pulses/litre • Flow rate: 5 digits, 6 mm high
• Programmable beginning and end of analog scale • Totalizer reset by means of a push button
• Selection of various types of units for flow rate and • Ingres protection: IP65(CH420L)
totalizer IP30(CH420R)
• Ambient temperature: 0...+60OC
(Dimensions pag. 7)
300 250
411
44
8
DFD-2 series Electronics Frequency Dividers • Precision No lost pulses
The DFD-2 series are rail mounting (DIN 46277) micro- • Temperature range -10oC......60oC
processor based control instruments for frequency division. • Output / input range 0.00000001.....0.4999
They are fully user programable and will adapt directly to • Output signal Open Collector 0.1 A 40 V
any TM44 turbine, COVOL output, or equivalent pulse TTL (5V)
generating output transducers. • Output pulse width approx. 50%
Applications duty circle
• Automater process control in any industry with batching
Ordering Information
or volume control for interfacing with PLC DFD-2 / a / vvv
• Interface with slow scanning PLC inputs a = Input Type
• Interface with PLC without calculations capacity =1 COVOL
• Interface with simple counters =2 Turbine Pick-up
=3 TTL
• Interface for electromechanical totalizing counters =4 for 12 volt proximity detectors
Benefits =5 for 5 volt pulse generators
• Very simple to use or open collector
vvv = Power supply voltage
• Direct interface to Turbines, Covol etc.
= 110 110 V ac 50/60 Hz
• Fullt programable by user = 230 230 V ac 50/60 Hz
• Standard DIN rail mounting = 240 240 V ac 50/60 Hz
• Connections with screw terminals for easy installation = 024 24 V ac 50/60 Hz
and maintenance = 12d 12 V dc
• No batteries needed, BCD switch programming
Technical Data
• Power supply 110,230,240,24 V ac 50-60 Hz
12 V dc
• Power consumption < 1 VA
• Input signal TM-44 20 mV...3 V ac, 0....2000 Hz
• Input signal COVOL Reed contact, 0....100 Hz
9
Dimensions: Series DFD-2 (rail DIN 46277) Series CI-420 (rail DIN 46277)
110
110
75
61,2
61,2
75
4,5 x 6 4,5 x 6
37,5 55 37,5
55