The VAMP 220 is an arc protection system featuring arc fault location indication, double trip criteria, and continuous self-supervision. It supports up to 10 slave units and 100 sensors, fulfilling relevant protection relay and EMC standards, and is designed for easy application and installation. Key specifications include an auxiliary voltage range of 40-265 V, rated phase current options of 1A or 5A, and an operating temperature range of -10 to +55°C.

Uploaded by

Kostas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
7 views2 pages

VL220EN

The VAMP 220 is an arc protection system featuring arc fault location indication, double trip criteria, and continuous self-supervision. It supports up to 10 slave units and 100 sensors, fulfilling relevant protection relay and EMC standards, and is designed for easy application and installation. Key specifications include an auxiliary voltage range of 40-265 V, rated phase current options of 1A or 5A, and an operating temperature range of -10 to +55°C.

Uploaded by

Kostas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Document ID: VL220EN.

002

VAMP 220
ARC PROTECTION SYSTEM

Product highlights
• Arc fault location indicated
• Double trip criteria: light and overcurrent
• Continuous self supervision
• Full selectivity even for complicated applications
• Fulfils protection relay standards
• High stability
• Fulfils relevant EMC standards
• Easy to apply and install
• Easy to retrofit
Main technical data

Master unit VAMP 220 Slave unit VAM12CD


Auxiliary voltage, Uaux 40…265 V ac / dc Auxiliary supply +24 Vdc
(optionally 18…36 Vdc) taken from master unit
Rated phase current In 1A or 5A via modular cable
Thermal Withstand 4 x In (continuous), 100 x Sensor connections
In (for 1 s) - arc sensors 10 pcs
Rated frequency fn 45…65 Hz - temperature sensor 1 pcs
Overcurrent setting, I> 0,9 … 6,0 x In - portable sensor 1 pcs
Operating time 7 ms Weight 0,4kg
Operating time CBFP 7, 80, 100, 150ms Dimension (w x h x d) 140 x 90 x 60 mm
Trip contacts 4 pcs NO Arc sensor VA1DA-
3 pcs NO, 1 pcs NC Auxiliary supply 12 Vdc
2 pcs NO, 2 pcs NC taken from slave unit
Alarm contacts 2 pcs Power consumption ≤ 2,5 mA
BIO inputs / outputs +48Vdc, 20mA Connection cable length 6 m, VA1DA-6
L> BIO lines (IN/OUT) 1 pcs (La>) 12 m, VA1DA-12
L> BIO lines (I> dependent) 1 pcs (Lb>) Weight 0,01 kg
L> BIO lines (IN) 1 pcs (Lc>)
Number of slave units supported 10 pcs / 100 sensors Temperature sensor VA1DT
Tests and environment Auxiliary supply 12 Vdc
taken from slave unit
Emission EN 55022 Power consumption 1 - 4 mA
Immunity IEC 60255-22-1, Connection cable length 6m
IEC 60255-11, Weight 0,01 kg
EN 61000-4-6,
EN 61000-4-5, Portable sensor VA1DT
EN6100-4-4, Auxiliary supply 12 Vdc
EN 61000-4-3, taken from slave unit
EN6100-4-2 Power consumption ≤ 2,5 mA
Insulation test IEC 60255-5 Connection cable length 6 m, VA1DA-6
Surge voltage IEC 60255-5 12 m, VA1DA-12
Vibration shock IEC 60255-21-1 Weight 0,01 kg
Operating temperature -10…+55° C
Relative humidity <95 %, no condensation Trip multiplier relay VAR 4 CE
allowed Auxiliary supply 24 Vdc
Degree of protection Inputs 1 NO contact
(IEC 60529) IP54 Trip outputs 4 pcs
Weight 4,2 kg Weight 0,4kg
Dimension (w x h x d) 209 x 155 x 225 mm Dimension (w x h x d) 140 x 90 x 60 mm
Measurements / INFO
Phase currents (per unit value)
Overcurrent pick-up setting (0,9 … 6 x In)
Information about 3 last activations:
(Slave and sensor address)
Total number of slave units and sensors
Temperature setting values and actual reading
Component failure information
(Slave unit number and error code)
Document ID: VL220EN.002

VAMP Ltd Street address: Runsorintie 7 Phone: +358 6 2121 100


Postal address: P.O.BOX 5, FIN-65381 Vaasa, Finland Fax: + 358 6 2121 105
Internet: www.vamp.fi
E-mail: [email protected]

You might also like