0% found this document useful (0 votes)
34 views2 pages

Fire Protection Plans

The document outlines the fire protection system specifications for a proposed two-storey vacation house, including a deluge sprinkler system and smoke detectors. It details the locations and quantities of fire alarms and smoke detectors throughout the building. Additionally, it includes design and approval information from the architect and owner.

Uploaded by

aprilfaithvistan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
34 views2 pages

Fire Protection Plans

The document outlines the fire protection system specifications for a proposed two-storey vacation house, including a deluge sprinkler system and smoke detectors. It details the locations and quantities of fire alarms and smoke detectors throughout the building. Additionally, it includes design and approval information from the architect and owner.

Uploaded by

aprilfaithvistan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

LEGENDS

PENDANT SPRINKLER

FIRE SUPPRESSION LINE

WATER LINE

A FIRE ALARM

SD SMOKE DETECTOR

SPECIFICATIONS
FIRE SUPRESSION SYSTEM TYPE
INFORMAL KITCHEN

DELUGE SPRINKLER SYSTEM


MODEL: BERMAD FP-400Y-3DC

PENDANT SPRINKLER
SMOKE DETECTOR
REFERENCE NO.: i9060
T&B 3 NO. OF SMOKE DETECTORS: 10

ALARM SYSTEM
SD

KITCHEN

MODEL: Bosch AVENAR 8000 Series


MAID'S BEDROOM
NO. OF FIRE ALARMS: 2
SPECIFICATIONS:
LAUNDRY AREA -DETECTION SENSITIVITY: HIGH SENSITIVITY TO DETECT SMOKE.
SD SD

DINING AREA BOYS -SOUND OUTPUT: LOUD ALARM SOUND FOR ALERTING./
BEDROOM -BATTERY LIFE: LONG-LASTING BACK UP BATTERY
TO ENSURE EFFECTIVITY EVEN WITHOUT POWER.

SD SD

T&B 1
LIVING AREA T&B 1
GIRLS
BEDROOM
SD SD

T&B 2

MASTER'S T&B

SD A

MASTER'S
BEDROOM
A

CARPORT
SD SD

BALCONY

1 2 SECOND FLOOR FIRE PROTECTION SYSTEM


GROUND FLOOR FIRE PROTECTION SYSTEM FP 1A SCALE: 1:100M
FP 1A SCALE: 1:100M

PLATE TITLE:
DRAWN BY:

PROPOSED TWO-STOREY
VISTAN, APRIL FAITH C. SHEET CONTENTS SHEET NO.:
VISTAN, APRIL FAITH C.
VACATION HOUSE
AFV +
CHECKED BY:
OWNER'S APPROVAL
AR. ARISTEO GARCIA

GF FIRE PROTECTION SYSTEM FP


STUDIOS
IAPOA NO.:

REG. NO. T.I.N. REG. NO. T.I.N. OWNER: DESIGNED BY:

SF FIRE PROTECTION SYSTEM 1A


VISTAN, APRIL FAITH C.

PTR. NO. DATE: PTR. NO. DATE: LOCATION: PROJECT NO.:


BRANCH LINE

AUTOMATIC SPRINKLERS

STANDPIPE

PLAN

CEILING LINE

SECTION
FIRE DEPT. CHECK VALVE
SIAMESE TWIN

ALARM VALVE

2 3
CHECK VALVE

SMOKE DETECTOR DETAIL PENDANT SPRINKLER HEAD DETAIL


SCALE: NTS SCALE: NTS
FP 1B FP 1B

TO STREET MAIN
VALVE

1 FIRE PROTECTION SYSTEM SECTION DETAIL


FP 1B SCALE: 1:100M

PLATE TITLE:
DRAWN BY:

PROPOSED TWO-STOREY
VISTAN, APRIL FAITH C. SHEET CONTENTS SHEET NO.:
VISTAN, APRIL FAITH C.
VACATION HOUSE
AFV +
CHECKED BY:
OWNER'S APPROVAL
AR. ARISTEO GARCIA

FIRE PROTECTION SYSTEM SECTION DETAIL FP


STUDIOS
IAPOA NO.:
T.I.N. REG. NO. T.I.N. OWNER: DESIGNED BY:

FIRE PROTECTION SYSTEM DETAILS


REG. NO.

1B
VISTAN, APRIL FAITH C.

PTR. NO. DATE: PTR. NO. DATE: LOCATION: PROJECT NO.: