Schirtec Ag Austria Catalogue 2024 With Sa60 97mtr Radius
Schirtec Ag Austria Catalogue 2024 With Sa60 97mtr Radius
1
3 1. Air Terminal
2. Ion Generator
2
3. Accelerator and Atmospheric Electrodes
4 4. Grounding Connection Terminal
The air terminal resists the biggest lightning strikes due to its high quality.
The Ion generator, induction coil and the protector have a high impedance. The generator is located inside of a special
epoxy resin to be protected from the environmental conditions.
The accelerator and atmospheric electrodes are designed in a way that they can be charged with different potentials.
The electrodes work as an additional ionization producing resource and as an accelerator.
The different protection capacities of the SCHIRTEC E.S.E. Lightning Conductors are regulated by the number of electrodes
and the ion generator's impedance.
The products of SCHIRTEC are in accordance to the new NFC 17-102: 2011 and the UNE 21186: 2011 Standards. The high
quality products are made of stainless steel and cause no risk for the environment, which is confirmed by TÜV Austria. The
discharge capacity of lightning is confirmed by the laboratories BET Germany and CTI Vienna.
The most important factor of SCHIRTEC E.S.E. Lightning Conductors is the protection radius, which depends on the level
calculation and the T value, found in the product's test reports.
The level of protection is calculated according to appendix B of the NF C 17-102.
The protection radius is calculated; Rp=(h(2D-h)+ L(2D+ L))0,5 h 5m..............................................................Eq.1
h(m): True height of the Schirtec E.S.E. above the surface to be protected
D(m): Standardised striking distance D =20m (level I), 30m (level II), 45m (level III) or 60m (level IV)
L (m):Triggering advance T measured during efficiency tests acc. to appendix C of the NF C 17-102 standard
which allows T to be calculated using the formula L=V. T , V=106 m/s from NF C 17-102.
Tested
Protection 17 µs 32 µs 65 µs 47 µs 73 µs
Radius T (µs)
-3-
www.schirtec.at
SCHIRTEC E.S.E. LIGHTNING CONDUCTORS TESTED
NFC 17-102 2011 VERSION
-4-
www.schirtec.at
SCHIRTEC CERTIFICATES & TEST REPORTS
-5-
www.schirtec.at
LIGHTNING CONDUCTOR TESTERS
All SCHIRTEC E.S.E. Lightning Conductors can be tested any time by utilizing the respective tester. The Tester indicates
OK (green LED) or FAULT (red LED). There are two different types of testers available.
STANDARD TESTER SA-1T
Name Description Dimension (cm)
SRC-2T
The solar tester works remotely. The testing device stores energy to operate for
24 hours by an exposition of 5-7 hours of sun light daily.
Installation Manual
1. The Testing Device is connected by a cable with
Charge E.S.E.-Tester Power
the E.S.E. Lightning Conductor. Point Connection Switch
Point
2. The Testing Device has to be switched ON.
3. A test has to be performed
Test unit; The power switch is switched to the I position and
the device is switched on.
The system can be powered from both the SOLAR energy and
the network.
1- Bend one 2- Attach the 3- Attach the 4- Fix the tape 5- Tighten the
end of the tape tape to the clip tape to the around the mast tape with
testing device a screwdriver
-6-
www.schirtec.at
Exothermic Welding SCHIRTEC
Exothermic welding is a process to join materials permanently with the conductors.
It is usually used for welding copper conductors but it is suitable for a wide range
of metals.
Product Packaging
-7-
www.schirtec.at
Exothermic Welding SCHIRTEC
Remote Welding Igniter
NEW
Open the mould by using Check if the mould is tightly To prevent unwanted leaks, Pour the needed amount
the handle clamp, then fit closed. place the metallic disk in of welding powder into the
the conductors into the Also the conductors must be the bottom of the mould. mould.
mould. fixed and well positioned.
Pour the starter powder Place the welding fuse over Press on/off button of the After the reaction, wait
over the main powder. the starter powder, then remote flint igniter and see for 15 seconds and then
It is located in the reverse close the mould cover. the ready indicator is active. open the mould.
side of the tube. Then press burn. Clean it with the mould
brush and the scraper.
-8-
www.schirtec.at
SLSC-10 (SCHIRTEC LIGHTNING STRIKE COUNTER)
Ref.No: Description Dimension (cm)
Description
The Lightning Strikes will be detected and recorded by the SLSC-10. This device can also show the
intact operation of the Lightning System.
Description
The Lightning Strikes will be detected and recorded by the SLSC-20. This device can also show the
intact operation of the Lightning System.
Operating Principle
SLSC-10 and SLSC-20 work with an inductive effect of the lightning strike current. The events are monitored by a mechanical
counter display. The counter includes a high frequency transformer.
-9-
www.schirtec.at
SLB (SCHIRTEC LED BEACON)
ELECTRICAL CHARACTERISTICS
Operation Voltage 12, 24, 48V DC
120V AC - 220V AC
Power Consumption 6W
Temperature Voltage -40 to 85°C
-10-
www.schirtec.at
SLB (SCHIRTEC LED BEACON)
STANDARDS
ICAO Annex 14, 4th Edition, July 2004
ICAO low intensity, type B
FAA AC No. 150/5345-43F, 2006
FAA type L810
APPLICATION
Low intensity obstruction light for marking obstacles that do not exceed 60m in
height
WARRANTY
Two years
-11-
www.schirtec.at
SCH-CAB50
-12-
www.schirtec.at
250µm COPPERBONDED EARTH ROD
Using copperbond earth rods is the most economical method of achieving a low earth
resistance. 99,95% pure copper is applied electrolytically to a high tensile strength, low
carbon steel core and forms a metallurgical bond between the steel core and the copper.
This combination provides lasting resistance to corrosion and makes the deep driving easy.
The threads are formed by a cold rolling process which makes the threads stronger than
cutthreads. The molecularly bonded copper covers along the full length of the threads. The
copper thickness is 0,25mm (250mc). The rods are extensible by a coupler made of bronze
or brass.
ACCESSORIES
Thread Shans Length Unit Stud Coupler - Bronze
Size Diameter (mm) Weight
(UNC-2A) (mm) (kg)
1200 1,53
5/8 inch 14,2 Head Spike Coupler - Brass
1500 1,88
1200 2,19
3/4 inch 17,2
EARTH ROD 1500 2,73
Specifications
Area of Usage
Honeycomb 1 kv 10 kV 2 mm
Honeycomb 20 kV 3 mm Tests
5
4
6
1 7
2
9
8
3 10
11
12
13
15
14
16
18
17
1
1 E.S.E. Lightning Conductors 10 Wall Holders
10
2
2 E.S.E. Lightning Conductors Tester 11 Down Conductors
11
3
3 Galvanized Mast 12 Lightning Strike Counter
12
4
4 Mast Base 13 Test Clamps
13
5
5 SCHIRTEC LED Beacon 14 Protection Pipe
14
6
6 Mast Clamp 15 Earthing Rod Clamps and Exothermic Welding
15
7
7 Mast Clip 16 Plastic, Concrete Inspection Pits
16
8
8 Plastic Holders for Isolated Floor/Roofs 17 SCHIRTEC Earthing Enhancement Material
17
9
9 Plastic Holders for Isolated Walls 18 Earthing Rods
18
-14-
www.schirtec.at
INTERNAL PROTECTION
SURGE PROTECTION DEVICES
POWER SUPPLY SYSTEMS LIGHTNING ARRESTER CLASS I
S 55 SB 120 SB 400 SB 500 SB 120S SB 400S SB 500S SBN-80 SBN-100 SZ-110 SZ-110/500 SJK-110
S45 = Encapsulated power spark gap Iimp= 60kA (L/N) , UN=230V/50Hz, Imax = 100 kA, Up 2,5 kV
S50-50 = Encapsulated power spark gap Iimp= 50kA(L/N), UN=230V/50Hz, Imax = 110 kA, Up 1,3 kV
S55 = Encapsulated power spark gap Iimp= 60kA (L/N) , UN=230V/50Hz, Imax = 100 kA, Up 4 kV
S50-3 = Encapsulated power spark gap Iimp= 50kA (L/N) , UN=230V/50Hz, Imax = 110 kA, Up 1,3 kV
S100 = Encapsulated power spark gap Iimp= 120kA (N/PE),Uc=255V/50Hz,Imax = 160kA,Up 2 kV
SB 120 = Lightning arrester class I. 85kA (8/20), UN= 120V, Imax = 100 kA,Up 950V
SB 230 = Lightning arrester class I. 85kA (8/20), UN= 230V, Imax = 100 kA, Up 1000V
SB 400 = Lightning arrester class I. 85kA (8/20) ,UN= 400V ,Imax = 100 kA, Up 1600 V
SB 500 = Lightning arrester class I. 85kA (8/20) ,UN= 500V ,Imax = 100 kA, Up 2100 V
SB 120S = Lightning arrester class I. 85kA (8/20) + dist.sig.,UN = 120V, Imax = 100 kA,Up 950V
SB 230S = Lightning arrester class I. 85kA (8/20)+ dist.sig., UN = 230V, Imax = 100 kA, Up 1000V
SB 400S = Lightning arrester class I. 85kA (8/20)+ dist.sig., UN = 400V , Imax = 100 kA, Up 1600 V
SB 500S = Lightning arrester class I. 85kA (8/20)+ dist.sig., UN = 500V , Imax = 100 kA, Up 2100 V
SBT 120 = Lightning arrester class I. 80kA (8/20) , UN = 120 V, Imax = 80kA, Up 1kV
SBT 230 = Lightning arrester class I. 80kA (8/20) , UN = 230 V , Imax = 80 kA , Up 2kV
SBT 400 = Lightning arrester class I. 80kA (8/20) , UN = 400 V , Imax = 80kA , Up 2kV
SBT 120S = Lightning arrester class I. 80kA (8/20)+dist.sig.UN = 120V, Imax = 80kA, Up 1kV
SBT 230S = Lightning arrester class I. 80kA (8/20)+dist.sig.UN = 230V , Imax = 80 kA , Up 2kV
SBT 400S = Lightning arrester class I. 80kA (8/20)+dist.sig. UN =400V , Imax = 80kA , Up 2kV
SBN-80 = Encapsulated Gas Discharge Tube 80kA, Uc = 255V/50 Hz, Imax = 120 kA, Up 1,3 kV
SBN-100 = Encapsulated Gas Discharge Tube 100kA, Uc = 255V/50Hz, Imax = 150kA, Up 1,5 kV
SZ110 = Encapsulated power spark gap Iimp = 110 kA (L/N) UN = 230 V AC, Up 2,5 kV
SZ110/500 = Encapsulated power spark gap Iimp = 110 kA (L/N) UN = 400 V AC, Up 2,5 kV
SJK110 = Encapsulated power spark gap Iimp = 110 kA (N/PE) UC = 255 V AC, Imax = 150 kA Up 2 kV
SB 25M SBM7 75 SBM7 150 SBM7 275 SBM7 320 SBM7 385 SBM7 440
SB 12,5-385 SB 12,5-440 SB 25
SBM7-75 = Lightning arrester class I Iimp = 7 kA (10/350) Uc= 75 V AC Imax=50 kA Up < 350 V
SBM7-75S = Lightning arrester class I Iimp = 7 kA (10/350) dist. sig. Uc= 75 V AC Imax=50 kA Up < 350 V
SBM7-150 = Lightning arrester class I Iimp = 7 kA (10/350) Uc= 150 V AC Imax=50 kA Up < 950 V
SBM7-150S = Lightning arrester class I Iimp = 7 kA (10/350) dist. sig. Uc= 150 V AC Imax=50 kA Up < 950 V
SBM7-275 = Lightning arrester class I Iimp = 7 kA (10/350) Uc= 275 V AC Imax=50 kA Up < 1,2 kV
SBM7-275S = Lightning arrester class I Iimp = 7 kA (10/350) dist. sig. Uc= 275 V AC Imax=50 kA Up<1,2 kV
SBM7-320 = Lightning arrester class I Iimp = 7 kA (10/350) Uc= 320 V AC Imax=50 kA Up < 1,3 kV
SBM7-320S = Lightning arrester class I Iimp = 7 kA (10/350) dist. sig. Uc= 320 V AC Imax=50 kA Up<1,3 kV
-15-
www.schirtec.at
SBM7-385 = Lightning arrester class I Iimp = 7 kA (10/350) Uc= 385 V AC Imax=50 kA Up < 1,5 kV
SBM7-385S = Lightning arrester class I Iimp = 7 kA (10/350) dist. sig. Uc= 385 V AC Imax=50 kA Up<1,5 kV
SBM7-440 = Lightning arrester class I Iimp = 7 kA (10/350) Uc= 440 V AC Imax=50 kA Up < 1,7 kV
SBM7-440S = Lightning arrester class I Iimp = 7 kA (10/350) dist. sig. Uc= 440 V AC Imax=50 kA Up<1,7 kV
SBM12,5-275 = Lightning arrester class I Iimp = 12,5 kA (10/350) Uc= 275 V AC Imax=100 kA Up < 1,2 kV
SBM12,5-275S = Lightning arrester class I Iimp = 12,5 kA (10/350) dist. sig. Uc= 275 V AC Imax=100 kA Up<1,2 kV
SBM12,5-320 = Lightning arrester class I Iimp = 12,5 kA (10/350) Uc= 320 V AC Imax=100 kA Up<1,3 kV
SBM12,5-320S = Lightning arrester class I Iimp = 12,5 kA (10/350) dist. sig. Uc= 320 V AC Imax=100 kA Up<1,3 kV
SBM12,5-385 = Lightning arrester class I Iimp = 12,5 kA (10/350) Uc= 385 V AC Imax=100 kA Up < 1,5 kV
SBM12,5-385S = Lightning arrester class I Iimp = 12,5 kA (10/350) dist. sig. Uc= 385 V AC Imax=100 kA Up<1,5 kV
SBM12,5-440 = Lightning arrester class I Iimp = 12,5 kA (10/350) Uc= 440 V AC Imax=100 kA Up < 1,6 kV
SBM12,5-440S = Lightning arrester class I Iimp = 12,5 kA (10/350) dist. sig. Uc= 440 V AC Imax=100 kA Up<1,6 kV
SBN25 = Encapsulated Gas Discharge Tube 25 kA Uc= 255 V AC Imax = 50 kA Up < 1,3 kV
SBN25P = Encapsulated Gas Discharge Tube 25 kA Uc= 255 V AC Imax = 50 kA Up < 1,3 kV
-16-
www.schirtec.at
POWER SUPPLY SYSTEMS LIGHTNING ARRESTER CLASS II
SCF - 120 = Surge arrester 20kA (8/20) SC - 400 = Surge arrester 15kA (8/20)
SCF - 230 = Surge arrester 20kA (8/20) SC- 120 S = Surge arrester 15kA (8/20) + sig.
SCF - 280 = Surge arrester 20kA (8/20) SC - 230 S = Surge arrester 20kA (8/20) + sig.
SCF- 400 = Surge arrester 20kA (8/20) SC - 280 S = Surge arrester 20kA (8/20) + sig.
SCF - 120 S = Surge arrester 20kA (8/20) + sig. SC - 400 S = Surge arrester 15kA (8/20) + sig.
SCF- 230 S = Surge arrester 20kA (8/20) + sig. SCN-20 = Encapsulated Gas Discharge Tube 20kA,
SCF- 280 S = Surge arrester 20kA (8/20) + sig. Uc=255V/50 Hz,Imax=20 kA, Up 1,3 kV
SCF- 400 S = Surge arrester 20kA (8/20) + sig. SSPU 1 - 120 = 1 pole, UN 120V
SCT - 230 = Surge arrester 15kA (8/20) SSPU 3 - 240 S = 3 poles, UN 3x400/230V + sig.
SCT - 280 = Surge arrester 15kA (8/20) SSPU 1 - 240 S = 1 pole, UN 230V + sig.
SCT - 230 S = Surge arrester 15kA (8/20) + sig. SSPU 1 - 240 = 1 pole, UN 230V
SCT - 280 S = Surge arrester 15kA (8/20) + sig. SSPU 3 - 240 = 3 poles, UN 3x400/230V
SC - 120 = Surge arrester 15kA (8/20) SSPU 3 - 120 = 3 poles, UN 3x208/120V
SC - 230 = Surge arrester 20kA (8/20) SSPU 3 - 400 = 3 poles, UN 3x680/400V
SC - 280 = Surge arrester 20kA (8/20) SPR 100 = Helping Connection Module
POWER SUPPLY SYSTEMS LIGHTNING ARRESTER CLASS III
COAXIAL PROTECTION
SCO-1G SCO-10P
SCO-2G SCO-1P SCO-7/16
SCO-2P
SGDT-100-RW SGDT-100